This study investigated the effects of various factors on the anaerobic degradation of nonylphenol (NP) in soil. The results show that the optimal pH for NP degradation was 7.0 and that the degradation rate was enhanced when the temperature was increased. The addition of compost enhanced NP degradation. The individual addition of the electron donors lactate, acetate, and pyruvate inhibited NP degradation. The high-to-low order of NP degradation rates under three anaerobic conditions was sulfate-reducing conditions > methanogenic conditions > nitrate-reducing conditions. The results show that sulfate-reducing bacteria, methanogen, and eubacteria are involved in the anaerobic degradation of NP, with sulfate-reducing bacteria being a major component of the soil. Of the anaerobic strains isolated from the soil samples, strain AT3 expressed the best ability to biodegrade NP. 相似文献
The removal of the organic toxic chemicals di-n-butyl phthalate (DBP), di-2-ethyl hexyl phthalate (DEHP), nonylphenol (NP), and bisphenol-A (BPA) by laccase obtained from the spent mushroom compost (SMC) of the white rot fungi, Ganoderma lucidum, was investigated. The optimal conditions for the extraction of laccase from SMC required using sodium acetate buffer (pH 5.0, solid : solution ratio 1 : 5), and extraction over 3 h at 4 °C. The removal of NP was enhanced by adding CuSO(4) (1 mM), MnSO(4) (0.5 mM), tartaric acid (20 mM), 2,2'-azino-bis-(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS; 1 mM), and 1-hydroxybenzotriazole (HBT; 20 mg L(-1)), with ABTS yielding a higher NP removal efficiency than the other additives. At a concentration of 2 mg L(-1), DBP, DEHP, NP, and BPA were almost entirely removed by laccase after incubation for 1 day. The removal efficiencies, in descending order of magnitude, were DBP > BPA > NP > DEHP. We believe that these findings could provide useful information for improving the efficiency of the removal of organic toxic chemicals in the environment. 相似文献
Environmental Science and Pollution Research - The toxic metal lead (Pb) can be harmful to human health in various manners, but is also considered as a distinguished tracer of environmental... 相似文献
In order to remove arsenic (As) from contaminated water, granular Mn-oxide-doped Al oxide (GMAO) was fabricated using the compression method with the addition of organic binder. The analysis results of XRD, SEM, and BET indicated that GMAO was microporous with a large specific surface area of 54.26 m2/g, and it was formed through the aggregation of massive Al/Mn oxide nanoparticles with an amorphous pattern. EDX, mapping, FTIR, and XPS results showed the uniform distribution of Al/Mn elements and numerous hydroxyl groups on the adsorbent surface. Compression tests indicated a satisfactory mechanical strength of GMAO. Batch adsorption results showed that As(V) adsorption achieved equilibrium faster than As(III), whereas the maximum adsorption capacity of As(III) estimated from the Langmuir isotherm at 25 °C (48.52 mg/g) was greater than that of As(V) (37.94 mg/g). The As removal efficiency could be maintained in a wide pH range of 3~8. The presence of phosphate posed a significant adverse effect on As adsorption due to the competition mechanisms. In contrast, Ca2+ and Mg2+ could favor As adsorption via cation-bridge involvement. A regeneration method was developed by using sodium hydroxide solution for As elution from saturated adsorbents, which permitted GMAO to keep over 75% of its As adsorption capacity even after five adsorption–regeneration cycles. Column experiments showed that the breakthrough volumes for the treatment of As(III)-spiked and As(V)-spiked water (As concentration = 100 μg/L) were 2224 and 1952, respectively. Overall, GMAO is a potential adsorbent for effectively removing As from As-contaminated groundwater in filter application.
Pulse-jet fabric filters (PJFFs) are widely used in U.S. industrial boiler applications and in utility and industrial boilers abroad. Their small size and reduced cost relative to more conventional reverse-gas baghouses makes the use of PJFFs appear to be an attractive particulate control option for utility boilers. This paper (Part 2 of a three-part series) summarizes the results of pilot PJFF studies sponsored by the Electric Power Research Institute at different utility sites in the United States. The purpose of these tests is to evaluate PJFF performance for U.S. fossil-fuel-fired applications. These data are also used to corroborate the results of a recent worldwide survey of PJFF user experience, as described in Part 1 of this series. Part 3 will provide a cost comparison of PJFFs to other particulate control options such as electrostatic precipitators and reverse-gas baghouses. 相似文献
This study identifies the natural background, anthropogenic background and distribution of contamination caused by heavy metal pollutants in soil in Chunghua County of central Taiwan by using a finite mixture distribution model (FMDM). The probabilities of contaminated area distribution are mapped using single-variable indicator kriging and multiple-variable indicator kriging (MVIK) with the FMDM cut-off values and regulation thresholds for heavy metals. FMDM results indicate that Cr, Cu, Ni and Zn can be individually fitted by a mixture model representing the background and contamination distributions of the four metals in soil. The FMDM cut-off values for contamination caused by the metals are close to the regulation thresholds, except for the cut-off value of Zn. The receiver operating characteristic (ROC) curve validates that indicator kriging and MVIK with FMDM cut-off values can reliably delineate heavy metals contamination, particularly for areas lacking background information and high heavy metal concentrations in soil. 相似文献
A Micro-Orifice Uniform Deposition Impactor (MOUDI) and a Nano-MOUDI were employed to determine the size-segregated mass distributions of ambient particulate matter (PM) and water-soluble ionic species for particulate constituents. In addition, gas precursors, including HCl, HONO, HNO3, SO2, and NH3 gases, were analyzed by an annular denuder system. PM size mass distribution, mass concentration, and ionic species concentration were measured during the day and at night during episode and non-episode periods in winter and summer. Average total suspended particle (TSP) concentrations during episode days in winter were as high as 153?±?33 μg/m3, and PM mass concentrations in summer were as low as one-third of that in winter. Generally, PM concentration at night was higher than that in the daytime in southern Taiwan during the sampling periods. In winter during the episode periods, the size-segregated mass distribution of PM mass concentration was mostly in the 0.32–3.2-μm range, and the PM concentration increased significantly in the range of 0.32–3.2 μm at night. Ammonium, nitrate, and sulfate were the dominant water-soluble ionic species in PM, contributing 34–48 % of TSP mass. High concentrations of ammonia (12.9–49 μg/m3) and SO2 (2.6–27 μg/m3) were observed in the gas precursors. The conversion ratio was high in the PM size range of 0.18–3.2 μm both during the day and at night in winter, and the conversion ratio of episode days was 20 % higher than that of non-episode days. The conversion factor was high for both nitrogen and sulfur species at nighttime, especially on episode days. 相似文献
The body of information presented in this paper is directed toward those individuals involved with handling hazardous materials, whether in actual use of such chemicals, or in monitoring atmospheric emissions. Although specifically relating experience in the design and testing of phosgene emission control equipment, it attempts to establish general guidelines for effectively dealing with emissions of hazardous materials. An approach for handling chemical pollutants having no established air quality emission standards is developed. The paper presents a technique for establishing process emissions at acceptably low levels to insure the health and safety of the general population as well as that of the process workers themselves. Methods, suitable for measuring phosgene at these low levels, have been investigated, and problems associated with such an investigation are discussed. While complete theoretical scrubber design criteria are beyond the scope of this paper, many of the "real world" problems which affected scrubber performance are presented. Finally, the practical aspects of process emissions control are illustrated by actual results from the system test. 相似文献