首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
The homogeneous degradation of the polychlorinated n-alkane, 1,2,9,10-tetrachlorodecane (T4C10), was studied in aqueous solutions of hydrogen peroxide, including Fenton and photo-Fenton reaction conditions. All solutions were adjusted to a pH of 2.8 and an ionic strength of 0.1 M NaClO4 prior to photolysis. T4C10 (2 x 10(-6) M) was substantially degraded by the H2O2/UV system (1.0 x 10(-2) M H2O2), with 60% disappearance in 20 min of irradiation in a photoreactor equipped with 300 nm lamps of light intensity 3.6 x 10(-5) Ein L(-1) min(-1) (established by ferrioxalate actinometry). The reaction produced stoichiometric amounts of chloride ion indicating complete dechlorination of the chlorinated n-alkane. T4C10 degraded very slowly under Fenton (Fe2+/H2O2/dark) and Fenton-like (Fe3+/H2O2/dark) conditions. However, when the same solutions were irradiated, T4C10 degraded more rapidly than in the H2O2/UV system, with 61% disappearance in 10 min of exposure. The rapid degradation is related to the enhanced degradation of hydrogen peroxide to oxidizing *OH radicals under photo-Fenton conditions. Degradation was inhibited in both the H2O2/UV and photo-Fenton systems by the addition of KI and tert-butyl alcohol due to *OH scavenging.  相似文献   

2.
Chen WS  Juan CN  Wei KM 《Chemosphere》2005,60(8):1072-1079
Fenton's reagent, UV/H2O2 and UV/Fenton's reagent were employed to mineralize dinitrotoluene (DNT) isomers and 2,4,6-trinitrotoluene (TNT) of spent acid in toluene nitration process. The bench-scale experiments were conducted to elucidate the influence of various operating variables on the performance of removal of total organic compounds (TOC) from spent acid, including reaction temperature, concentration of ferrous ion and H2O2 dosage. It is remarkable that organic compounds were completely mineralized by Fenton oxidation, of which removal efficiency is superior to that of UV/H2O2. Nevertheless, it makes slight difference between Fenton oxidation and UV/Fenton oxidation. According to the spectra identified by gas chromatograph/mass spectrometer (GC/MS), it is proposed that oxidative degradation of DNT isomers leads to o-, m-, p-mononitrotoluene (MNT) and 1,3-dinitrobenzene respectively. Besides, the oxidation of 2,4,6-TNT gives the 1,3,5-trinitrobenzene intermediate. Apparently, Fenton oxidation is promising for purification of spent acid industrially.  相似文献   

3.
Katsumata H  Kaneco S  Suzuki T  Ohta K  Yobiko Y 《Chemosphere》2007,69(8):1261-1266
2,3,7,8-Tetrachlorodibenzo-p-dioxin (2,3,7,8-TeCDD) was rapidly decreased by sonication in aqueous solution. The degradation efficiency was strongly influenced by ultrasonic power and reaction temperature. An initial 2,3,7,8-TeCDD concentration of 20 ng l(-1) was completely degraded within 60 min under sonochemical conditions using a 20 kHz frequency with a 150 W ultrasound power. The activation energy is 21.9 kJ/mol in the temperature range of 10-40 degrees C, suggesting a diffusion-controlled reaction. To increase the efficiency of 2,3,7,8-TeCDD treatment, degradation system combined ultrasound with Fe(III) (2 x 10(-4)mol l(-1)) and UV irradiation. Both UV and Fe(III) induced Fenton, Fenton-like and photo-Fenton reactions, leading to additional OH radicals and rapid 2,3,7,8-TeCDD removal.  相似文献   

4.
The photodegradation of monuron (3-(4-chlorophenyl)-1,1-dimethylurea) in aqueous solutions under simulated solar irradiation has been conducted by different advanced oxidation processes (UV/H(2)O(2), UV/H(2)O(2)/Fe(2+), UV/H(2)O(2)/TiO(2), UV/TiO(2), dark H(2)O(2)/Fe(3+)). The degradation rates were always higher for the homogeneous catalysis in photo-Fenton reactions (UV/H(2)O(2)/Fe(2+)) compared to the heterogeneous photocatalytic systems (TiO(2)/UV and UV/H(2)O(2)/TiO(2)). Optimal concentrations of Fe(2+) and H(2)O(2) for the abatement of the herbicide in the photo-Fenton system were found to be 1 mM Fe(II) and 10 mM H(2)O(2). Several intermediary products were identified using large volume injection micro-liquid chromatography with UV detection (mu-LC-UV), mu-LC-MS and GC-MS techniques and a degradation mechanism has been proposed.  相似文献   

5.
Arienzo M 《Chemosphere》2000,40(4):441-448
The possibility to clean-up TNT contaminated soil, 400 mg TNT kg-1, surrounding Nebraska Ordnance Plant's (US), below the USEPA goal of 17.2 mg TNT kg-1 using Fenton oxidation (Fe2+ + H2O2), Fe0 reduction, combined Fe0/H2O2 and CaO2 was explored at pilot scale. Treatments were performed in a 60 l airlift reactor, which was a prototype of larger commercial unit. All the treatments reduced TNT soil concentration below the required clean-up goal and in shorter time with respect to bench scale. Using 2% (w/w) Fe0, TNT soil concentration reduced below the required standard just within 4 h. No significant TNT destruction improvement was observed when 2% Fe0 (w/w soil) was combined with four sequential additions of 0.25% H2O2. Laboratory experiments with 14C-TNT indicated that most of the 14C, approximately 80%, was unextractable residue. A time greater than 24 h was required either with Fenton reagent, 8 x (80 mg Fe2+ L-1 + 0.125% H2O2) or 0.2% (w/w) CaO2. The optimal performance of Fenton reagent was obtained when the reagent was added in eight increments rather than in a single or double dose and less cumulative amount of H2O2 (0.75%) was required with respect to bench scale (1%).  相似文献   

6.
Maezono T  Tokumura M  Sekine M  Kawase Y 《Chemosphere》2011,82(10):1422-1430
Dynamic behaviors of hydroxyl (OH) radical generation and consumption in photo-Fenton oxidation process were investigated by measuring OH radical concentration during the discoloration of azo-dye Orange II. The effects of operating parameters for photo-Fenton discoloration, i.e. dosages of H2O2 and Fe, initial dye concentration, solution pH and UV irradiation, on the generation and consumption of OH radicals playing the main role in advanced oxidation processes were extensively studied. The scavenger probe or trapping technique in which coumarin is scavenger of OH radical was applied to estimate OH radical concentration in the photoreactor during the photo-Fenton discoloration process. The OH radical generation was enhanced with increasing the dosages of Fenton regents, H2O2 and Fe. At the initial stage of photo-Fenton discoloration of Orange II, the OH radical concentration rapidly increased (Phase-I) and the OH radical concentration decreased after reaching of OH radical concentration at maximum value (Phase-II). The decrease in OH radical concentration started when the complete discoloration of Orange II was nearly achieved and the H2O2 concentration became rather low. The dynamic behavior of OH radical concentration during the discoloration of Orange II was found to be strongly linked with the change in H2O2 concentration. The generation of OH radical was maximum at solution pH of 3.0 and decreased with an increase of solution pH. The OH radical generation rate in the Fenton Process was rather slower than that in the photo-Fenton process.  相似文献   

7.
In the present study, selected advanced oxidation processes (AOPs)—namely, photo-Fenton (with Fe2+, Fe3+, and potassium ferrioxalate—FeOx—as iron sources), solar photo-Fenton, Fenton, and UV/H2O2—were investigated for degradation of the antineoplastic drug mitoxantrone (MTX), frequently used to treat metastatic breast cancer, skin cancer, and acute leukemia. The results showed that photo-Fenton processes employing Fe(III) and FeOx and the UV/H2O2 process were most efficient for mineralizing MTX, with 77, 82, and 90 % of total organic carbon removal, respectively. MTX probably forms a complex with Fe(III), as demonstrated by voltammetric and spectrophotometric measurements. Spectrophotometric titrations suggested that the complex has a 2:1 Fe3+:MTX stoichiometric ratio and a complexation constant (K) of 1.47 × 104 M–1, indicating high MTX affinity for Fe3+. Complexation partially inhibits the involvement of iron ions and hence the degradation of MTX during photo-Fenton. The UV/H2O2 process is usually slower than the photo-Fenton process, but, in this study, the UV/H2O2 process proved to be more efficient due to complexing of MTX with Fe(III). The drug exhibited no cytotoxicity against NIH/3T3 mouse embryonic fibroblast cells when oxidized by UV/H2O2 or by UV/H2O2/FeOx at the concentrations tested.  相似文献   

8.
INTENTION, GOAL, SCOPE, BACKGROUND: Since the intermediate products of some compounds can be more toxic and/or refractory than the original compund itself, the development of innovative oxidation technologies which are capable of transforming such compounds into harmless end products, is gaining more importance every day. Advanced oxidation processes are one of these technologies. However, it is necessary to optimize the reaction conditions for these technologies in order to be cost-effective. OBJECTIVE: The main objectives of this study were to see if complete mineralization of 4-chlorophenol with AOPs was possible using low pressure mercury vapour lamps, to make a comparison of different AOPs, to observe the effect of the existence of other ions on degradation efficiency and to optimize reaction conditions. METHODS: In this study, photochemical advanced oxidation processes (AOPs) utilizing the combinations of UV, UV/H2O2 and UV/H2O2/Fe2+ (photo-Fenton process) were investigated in labscale experiments for the degradation and mineralization of 4-chlorophenol. Evaluations were based on the reduction of 4-chlorophenol and total organic carbon. The major parameters investigated were the initial 4-chlorophenol concentration, pH, hydrogen peroxide and iron doses and the effect of the presence of radical scavengers. RESULTS AND DISCUSSION: It was observed that the 4-chlorophenol degradation efficiency decreased with increasing concentration and was independent of the initial solution pH in the UV process. 4-chlorophenol oxidation efficiency for an initial concentration of 100 mgl(-1) was around 89% after 300 min of irradiation in the UV process and no mineralization was achieved. The efficiency increased to > 99% with the UV/H2O2 process in 60 min of irradiation, although mineralization efficiency was still around 75% after 300 min of reaction time. Although the H2O2/4-CP molar ratio was kept constant, increasing initial 4-chlorophenol concentration decreased the treatment efficiency. It was observed that basic pHs were favourable in the UV/H2O2 process. The results showed that the photo-Fenton process was the most effective treatment process under acidic conditions. Complete disappearance of 100 mgl(-1) of 4-chlorophenol was achieved in 2.5 min and almost complete mineralization (96%) was also possible after only 45 min of irradiation. The efficiency was negatively affected from H2O2 in the UV/H2O2 process and Fe2+ in the photo-Fenton process over a certain concentration. The highest negative effect was observed with solutions containing PO4 triple ions. Required reaction times for complete disappearance of 100 mgl(-1) 4-chlorophenol increased from 2.5 min for an ion-free solution to 30 min for solutions containing 100 mgl(-1) PO4 triple ion and from 45 min to more than 240 min for complete mineralization. The photodegradation of 4-chlorophenol was found to follow the first-order law. CONCLUSION: The results of this study showed that UV irradiation alone can degrade 4-CP, although at very slow rates, but cannot mineralize the compound. The addition of hydrogen peroxide to the system, the so-called UV/H2O2 process, significantly enhances the 4-CP degradation rate, but still requires relatively long reaction periods for complete mineralization. The photo-Fenton process, the combination of homogeneous systems of UV/H2O2/Fe2+ compounds, produces the highest photochemical elimination rate of 4-CP and complete mineralization is possible to achieve in quite shorter reaction periods when compared with the UV/H2O2 process. RECOMMENDATIONS AND OUTLOOK: It is more cost effective to use these processes for only purposes such as toxicity reduction, enhancement of biodegradability, decolorization and micropollutant removal. However the most important point is the optimization of the reaction conditions for the process of concern. In such a case, AOPs can be used in combination with a biological treatment systems as a pre- or post treatment unit providing the cheapest treatment option. The AOP applied, for instance, can be used for toxicity reduction and the biological unit for chemical oxygen demand (COD) removal.  相似文献   

9.
Kinetics and mechanism of TNT degradation in TiO2 photocatalysis   总被引:9,自引:0,他引:9  
Son HS  Lee SJ  Cho IH  Zoh KD 《Chemosphere》2004,57(4):309-317
The photocatalytic degradation of TNT in a circular photocatalytic reactor, using a UV lamp as a light source and TiO(2) as a photocatalyst, was investigated. The effects of various parameters such as the initial TNT concentration, and the initial pH on the TNT degradation rate of TiO(2) photocatalysis were examined. In the presence of both UV light illumination and TiO(2) catalyst, TNT was more effectively degraded than with either UV or TiO(2) alone. The reaction rate was found to obey pseudo first-order kinetics represented by the Langmuir-Hinshelwood model. In the mineralization study, TNT (30 mg/l) photocatalytic degradation resulted in an approximately 80% TOC decrease after 150 min, and 10% of acetate and 57% of formate were produced as the organic intermediates, and were further degraded. NO(-)(3) NO(-)(2), and NH(+)(4) were detected as the nitrogen byproducts from photocatalysis and photolysis, and more than 50% of the total nitrogen was converted mainly to NO(-)(3)in the photocatalysis. However, NO(-)(3) did not adsorbed on the TiO(2) surface. TNT showed higher photocatalytic degradation efficiency at neutral and basic pH.  相似文献   

10.
Kavitha V  Palanivelu K 《Chemosphere》2004,55(9):1235-1243
The efficiency of different Fenton-related oxidative processes such as Fenton, solar-Fenton and UV-Fenton were examined using phenol as a model compound in simulated and industrial wastewater. A batch study was conducted to optimize parameters like pH, hydrogen peroxide concentration and ferrous ion concentration governing the Fenton process. At optimum conditions, different Fenton-related processes were compared for the degradation of phenol. Increased degradation and mineralisation efficiency were observed in photo-Fenton processes as compared to conventional Fenton process. The maximum mineralising efficiency for phenol with Fenton, solar and UV-Fenton processes were 41%, 96% and 97% respectively. In Fenton process, carboxylic acids like acetic acid and oxalic acid were formed as end products during the degradation of phenol while in photo-Fenton processes, both these ions were identified during the early stages of phenol degradation and were oxidized almost completely at 120 min of the reaction time. In photo-Fenton processes (solar and UV light) complete degradation were observed with 0.4 mM of Fe2+ catalyst as compared to 0.8 mM of Fe2+ in conventional Fenton process. In Fenton and solar-Fenton processes, an iron reusability study was performed to minimize the amount of iron used in treatment process. The efficacy of Fenton and solar-Fenton processes was applied to effluent from phenol resin-manufacturing unit for the removal and mineralisation of phenol.  相似文献   

11.
The present work compares the efficiency of homogenous Fenton and photo-Fenton processes in the presence of Fe(III)–EDDS complex under different experimental conditions. 4-tert-Butylphenol (4-t-BP), which is one of the endocrine disrupting chemicals, was used as a model pollutant to investigate the Fenton and photo-Fenton application. The efficiency of homogenous photo-Fenton process was significantly much higher than homogenous Fenton process, which is due to the rapid formation of Fe2+ under UV irradiation of the iron complex and the photochemical formation of HO? from the photolysis of the complex Fe(III)–EDDS. Through the degradation of 4-t-BP, the effect of Fe(III)–EDDS concentration, H2O2 concentration, pH, and oxygen was investigated in both processes. Such trend was also correlated with pH calculating the polychromatic Fe2+ quantum yield formation at pH 4.0, 6.0, and 8.6. The results showed that at high Fe(III)–EDDS and H2O2 concentrations, a negative effect was found. By the way, the Fenton process was found to be enhanced at basic pH. These results can be very useful for the use and optimization of such iron complex in water treatment process as function of different physico-chemical conditions.  相似文献   

12.
Fenton组合工艺处理焦化厂生化出水的应用研究   总被引:2,自引:1,他引:1  
比较了Fenton氧化、Fenton氧化+活性炭及Fenton氧化+生物活性炭工艺对焦化厂生化出水的处理效果.结果表明,Fe2+、H2O2的投加量分别为56、27.2 mg/L时,Fenton氧化工艺对水样的UV254、颜色度(VIS380)、COD和总氰均有较好的去除效果;Fenton氧化+活性炭工艺在有效去除UV254、VIS380、COD和总氰的同时,能强化活性炭的吸附效果,并能显著提高水样的生化性能;Fenton氧化+生物活性炭工艺能有效去除UVM254,VIS380、COD与总氰,使出水达到<污水综合排放标准>(GB 8978-1996)一级标准.  相似文献   

13.
BACKGROUND: The spent waste of aliphatic chlorinated solvents has caused severe deterioration of groundwater quality. Trichloromethane (TCM), which shows health and toxicological effects on human beings, was selected as a model compound to be dechlorinated through a redox system. METHODS: The Fe0-based system including Fe0/H2O, Fe0/UV, Fe0/H2O2, and Fe0/UV/H2O2 was explored to evaluate its performance in dechlorinating TCM. H2O2 was dosed at later reaction time points to initiate Fenton or photo-Fenton reactions. The first two systems demonstrate the reductive dechlorination of TCM by Fe0-released electrons, while the latter two show dechlorination of TCM by both electron reduction and hydroxyl radical oxidation. The system parameters of TCM remaining, Cl- buildup, Fe2+ accumulation, H2O2 residue, and ORP were measured to describe different redox characteristics of TCM dechlorination. The Cl- buildup was used as a way to describe the degree of TCM dechlorination in an open reaction system. RESULTS: Reductive dechlorination efficiencies of TCM were 5% and 6% for the systems of Fe0/H2O and Fe0/UV, respectively. In contrast, the Fe/H2O2 and Fe0/UV/H2O2 systems were capable of dechlorinating TCM reductively and oxidatively by 14% and 15%, respectively. The presence of UV light was found to retard the dissolution of Fe2+, but it enhanced the rate of chloride buildup, based on the comparison of Fe0/H2O and Fe0/UV systems. In addition, WV irradiation plays only a minor role in the Fe0/UV/H2O2 system, in view of TCM dechlorination. Application of small amount of H2O2 results in the increase of Fe2+ accumulation rate in the Fe0/H2O2 system. CONCLUSIONS: TCM was dechlorinated mostly through post Fenton oxidation; reductive reaction represents a less efficient way to dechlorinate TCM. The efficiencies of overall TCM dechlorination for the two systems of Fe0/H2O2 and Fe0/UV/ H2O2 are comparable to each other, and this implies that the presence of UV irradiation imposes no significant enhancement. RECOMMENDATIONS AND OUTLOOKS: It is highly recommended to initiate effective redox dechlorination of TCM with the system of Fe0/H2O2, where the H2O2 in excess is applied at a later reaction time point.  相似文献   

14.
Carbofuran, one of the most toxic and biorefractory carbamate compounds, is widely used in insecticides in Taiwan (9-18% of total insecticides production per year). In the present study, a central composite design experiment was used to study the effect of photo-Fenton treatment on carbofuran solution and to optimize the process variables such as carbofuran concentration (1-100 mg L(-1)), H(2)O(2) dosage rate (0.25-6 mg L(-1) min(-1)) and Fe(3+) dosage (1-50 mg L(-1)), which influenced the efficiency of carbofuran degradation and mineralization. The results indicated that all the variables investigated in this study had significant roles in the degradation and mineralization of carbofuran in solution. The carbofuran degradation and mineralization efficiencies were increased with increase in H(2)O(2) dosage rate and Fe(3+) dosage, and with decrease in carbofuran concentration. Furthermore, optimum values of both H(2)O(2) dosage rate and Fe(3+) dosage were found to shift to higher values as carbofuran concentration increased. Based on the model obtained in this study, optimum H(2)O(2) dosage rate and Fe(3+) dosage were found to be 4 mg L(-1) min(-1) and 20 mg L(-1), respectively, for 51 mg L(-1) of carbofuran concentration. Under these conditions, carbofuran was completely removed within 30 min and coupled with 78% mineralization at the end of experiment.  相似文献   

15.
A coupled solar photo-Fenton (chemical) and biological treatment has been used to remove biorecalcitrant diuron (42 mg l(-1)) and linuron (75 mg l(-1)) herbicides from water at pilot plant scale. The chemical process has been carried out in a 82 l solar pilot plant made up by four compound parabolic collector units, and it was followed by a biological treatment performed in a 40 l sequencing batch reactor. Two Fe(II) doses (2 and 5 mg l(-1)) and sequential additions of H2O2 (20 mg l(-1)) have been used to chemically degrade the initially polluted effluent. Next, biodegradability at different oxidation states has been assessed by means of BOD/COD ratio. A reagent dose of Fe=5 mg l(-1) and H2O2=100 mg l(-1) has been required to obtain a biodegradable effluent after 100 min of irradiation time. Finally, the organic content of the photo-treated solution has been completely assimilated by a biomass consortium in the sequencing batch reactor using a total suspended solids concentration of 0.2 g l(-1) and a hydraulic retention time of 24h. Comparison between the data obtained at pilot plant scale (specially the one corresponding to the chemical step) and previously published data from a similar system performing at laboratory scale, has been carried out.  相似文献   

16.
A novel process for degradation of toluene in the gas-phase using heterogeneous gas-liquid photocatalytic oxidation has been developed. The degradation of toluene gas by photo-Fenton reaction in the liquid-phase has experimentally examined. The photo-Fenton reaction in the liquid-phase could improve the overall toluene absorption rate by increasing the driving force for mass transfer and as a result enhance the removal of toluene in the exhaust gas. The toluene concentrations in the inlet gas were varied in the range from 0.0968 to 8.69gm(-3) with initial hydrogen peroxide concentration of 400mgl(-1) and Fe dose of 5.0mgl(-1). It was found that toluene in the inlet gas was almost completely dissolved into water and degraded in the liquid-phase for the inlet toluene gas concentration of less than 0.42gm(-3). The dynamic process of toluene gas degradation by the photo-Fenton reaction providing information for reaction kinetics and mass transfer rate was examined. Toluene removal kinetic analysis indicated that photo-Fenton degradation was significantly affected by H(2)O(2) concentration. The experimental results were satisfactorily described by the predictions simulated using the simplified tanks-in-series model combined with toluene removal kinetic analysis. The present results showed that the proposed chemical absorption process using the photo-Fenton heterogeneous gas-liquid photocatalytic oxidation is very effective for degradation of volatile organic gases.  相似文献   

17.
Contaminated water and soil at active or abandoned munitions plants is a serious problem since these compounds pose risks to human health and can be toxic to aquatic and terrestrial life. Our objective was to determine if zero-valent iron (Fe(0)) could be used to promote remediation of water and soil contaminated with 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX). As little as 1% Fe(0) (w/v) removed 70 mg TNT litre(-1) from aqueous solution within 8 h and removed 32 mg RDX litre(-1) within 96 h. Treating slurries (1:5 soil:water) of highly contaminated soil (5200 mg TNT and 6400 mg RDX kg(-1) soil) from the former Nebraska Ordnance Plant (NOP) with 10% Fe(0) (w/w soil) reduced CH(3)CN-extractable TNT and RDX concentrations below USEPA remediation goals (17.2 mg TNT and 5.8 mg RDX kg(-1)). Sequential treatment of a TNT-contaminated solution (70 mg TNT litre(-1) spiked with (14)C-TNT) with Fe(0) (5% w/v) followed by H(2)O(2) (1% v/v) completely destroyed TNT and removed about 94% of the (14)C from solution, 48% of which was mineralized to (14)CO(2) within 8 h. Fe(0)-treated TNT also was more susceptible to biological mineralization. Our observations indicate that Fe(0) alone, Fe(0) followed by H(2)O(2), or Fe(0) in combination with biotic treatment can be used for effective remediation of munitions-contaminated water and soil.  相似文献   

18.
Photo-Fenton degradation of dichloromethane for gas phase treatment   总被引:2,自引:0,他引:2  
A continuous photo-Fenton process has been used for the degradation of gaseous dichloromethane (DCM). By absorbing gaseous DCM into a reactive Fenton mixture, the scrubbing and degradation processes could be completed in the one reactor. Operating with a Dark Fenton solution did not result in removal of DCM any better than simply using MilliQ water. This was because the Fe(II) quickly converted to Fe(III) but was unable to regenerate. After a short time, the Fenton process was no longer operating and the DCM quickly accumulated in the reaction solution, preventing further accumulation due to a decreasing concentration gradient in the reactive solution. However, by using UV light and increasing the retention time from 20 to 50 s, there was sufficient time for the reactive solution to regenerate and continuous operation could achieve at least 65% removal of DCM from the gaseous phase at ambient temperature.  相似文献   

19.
The main disadvantage of using iron mineral in Fenton-like reactions is that the decomposition rate of organic contaminants is slower than in classic Fenton reaction using ferrous ions at acidic pH. In order to overcome these drawbacks of the Fenton process, chelating agents have been used in the investigation of Fenton heterogeneous reaction with some Fe-bearing minerals. In this work, the effect of new iron complexing agent, ethylenediamine-N,N'-disuccinic acid (EDDS), on heterogeneous Fenton and photo-Fenton system using goethite as an iron source was tested at circumneutral pH. Batch experiments including adsorption of EDDS and bisphenol A (BPA) on goethite, H2O2 decomposition, dissolved iron measurement, and BPA degradation were conducted. The effects of pH, H2O2 concentration, EDDS concentration, and goethite dose were studied, and the production of hydroxyl radical (?OH) was detected. The addition of EDDS inhibited the heterogeneous Fenton degradation of BPA but also the formation of ?OH. The presence of EDDS decreases the reactivity of goethite toward H2O2 because EDDS adsorbs strongly onto the goethite surface and alters catalytic sites. However, the addition of EDDS can improve the heterogeneous photo-Fenton degradation of BPA through the propagation into homogeneous reaction and formation of photochemically efficient Fe-EDDS complex. The overall effect of EDDS is dependent on the H2O2 and EDDS concentrations and pH value. The high performance observed at pH 6.2 could be explained by the ability of O 2 ?? to generate Fe(II) species from Fe(III) reduction. Low concentrations of H2O2 (0.1 mM) and EDDS (0.1 mM) were required as optimal conditions for complete BPA removal. These findings regarding the capability of EDDS/goethite system to promote heterogeneous photo-Fenton oxidation have important practical implications for water treatment technologies.  相似文献   

20.
Che H  Lee W 《Chemosphere》2011,82(8):1103-1108
Selective redox degradation of chlorinated aliphatics by Fenton reaction in pyrite suspension was investigated in a closed system. Carbon tetrachloride (CT) was used as a representative target of perchlorinated alkanes and trichloroethylene (TCE) was used as one of highly chlorinated alkenes. Degradation of CT in Fenton reaction was significantly enhanced by pyrite used as an iron source instead of soluble Fe. Pyrite Fenton showed 93% of CT removal in 140 min, while Fenton reaction with soluble Fe(II) showed 52% and that with Fe(III) 15%. Addition of 2-propanol to the pyrite Fenton system significantly inhibited degradation of TCE (99% to 44% of TCE removal), while degradation of CT was slightly improved by the 2-propanol addition (80-91% of CT removal). The result suggests that, unlike oxidative degradation of TCE by hydroxyl radical in pyrite Fenton system, an oxidation by the hydroxyl radical is not a main degradation mechanism for the degradation of CT in pyrite Fenton system but a reductive dechlorination by superoxide can rather be the one for the CT degradation. The degradation kinetics of CT in the pyrite Fenton system was decelerated (0.13-0.03 min−1), as initial suspension pH decreased from 3 to 2. The formation of superoxide during the CT degradation in the pyrite Fenton system was observed by electron spin resonance spectroscopy. The formation at initial pH 3 was greater than that at initial pH 2, which supported that superoxide was a main reductant for degradation of CT in the pyrite Fenton system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号