 共查询到20条相似文献,搜索用时 31 毫秒
1.
Methods to monitor contamination of workplaces with antineoplastic drugs have been developed and validated. Cyclophosphamide (CP) was used as a model compound as it is one of the most commonly used antineoplastic drugs. A wipe sampling method to detect contamination with CP at surfaces was developed. A personal air sampling method to sample gas and vapour on solid sorbent tubes and particles with filters was also developed. Wipe and filter samples were extracted and sorbent samples were eluted, all with ethyl acetate. The samples were analysed with liquid chromatography tandem mass spectrometry. (2)H(6)-labelled cyclophosphamide was used as an internal standard. The between-day precision was 2-5% for wipe samples, 4-6% for sorbent samples and 3-8% for filter samples. The limit of detection was 0.02 ng CP per sample for the wipe and filter methods and 0.03 ng CP per sample for the solid sorbent method. Wipe sampling on surfaces made of different materials resulted in mean recoveries between 78-106%. The desorption recovery was between 97-102% for the wipe samples, 97% for the sorbent samples and 101% for the filter samples. Samples were stable for up to 2 months at 5 degrees C and -20 degrees C and for about 2 d at room temperature. The developed methods were applied to the measurement of contamination with CP in a hospital pharmacy. Trace amounts of CP, 1.3 and 1.4 ng, were detected on surfaces in the pharmacy.  相似文献   

2.
Mercury vapour adsorption tubes manufactured for pumped sampling and analysis have been evaluated for their performance as passive samplers. This has been done by exposing these tubes in a novel micro-exposure chamber. The uptake rates of these tubes have been found to be low (approximately 0.215 ml min(-1)) as compared to bespoke passive samplers for mercury vapour (typically in excess of 50 ml min(-1)). The measured uptake rates were shown to vary significantly between tubes and this was attributed to the variability in the air-sorbent interface and the proportion of the cross sectional area removed by the crimp in the quartz tubes used to secure the sorbent material. As a result of this variability the uptake rate of each tube must be determined using the micro-exposure chamber prior to deployment. Results have shown that the uptake rate determined in the micro-exposure chamber is invariant of concentration, and therefore these uptakes rates may be determined at a high mercury vapour concentration for many tubes at once in less than one hour. The uptake rate of the adsorption tubes under these conditions may be determined with a precision of 5%. Measurements made on a limited field trial in indoor and outdoor ambient air have shown that these tubes give results in acceptable agreement with more traditional pumped sampling methods, although longer sampling periods are required in order to reduce the uncertainty of the measurement, which is currently approximately 30%.  相似文献   

3.
The objective of this study was to determine filter materials and extraction methods that are appropriate to use for environmental sampling of B. anthracis. Four types of filters were tested: mixed cellulose ester (MCE) with a pore size of 3 microm, polytetrafluoroethylene (PTFE) with pore sizes of 1 and 3 microm, and gelatin with a pore size of 3 microm. Bacillus subtilis var. niger endospores (also known as Bacillus globigii[BG]) were used as a surrogate for B. anthracis. Endospores were collected into Button Inhalable Aerosol Samplers with sampling times of 15 minutes, 1 hour, and 4 hours. Physical collection efficiency was determined by measuring upstream and downstream B. subtilis concentrations with an optical particle counter. Vortexing with ultrasonic agitation and vortexing with shaker agitation extraction methods were evaluated. The MCE, 1 microm PTFE, and gelatin filters provided physical collection efficiencies of 94% or greater. The 3 microm PTFE filter showed inconsistent physical efficiency characteristics between filters. Epifluorescence microscopic analysis of the gelatin filter extraction fluid revealed the presence of contamination by non-culturable bacteria. Mean differences for microbial culturability were not statistically significant for filter materials and extraction methods. However, the vortexing with shaker agitation extraction method resulted in higher total microbial counts in the extraction fluids for MCE and 1 microm PTFE filters when compared to vortexing with ultrasonic agitation. In summary, the MCE and 1 microm PTFE filters in combination with vortexing and shaker extraction demonstrated the best performance for the filter collection and extraction of BG spores.  相似文献   

4.
The dialdehyde glyoxal (ethanedial) is an increasingly used industrial chemical with potential occupational health risks. This study describes the development of a personal sampling methodology for the determination of glyoxal in workroom air. Among the compounds evaluated as derivatizing agents; N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH), 1,2-phenylenediamine (OPDA), 1-dimethylaminonaphthalene-5-sulfonylhydrazine (dansylhydrazine, DNSH) and 2,4-dinitrophenylhydrazine (DNPH), DNPH was the only reagent that was suitable. Several different samplers were evaluated for sampling efficiency of glyoxal in workroom air using DNPH as derivatizing agent; in-house DNPH coated silica particles packed in two different types of glass tubes, impingers containing acidified DNPH solution, filter cassettes containing glass fibre filters coated with DNPH, a commercially available solid phase cartridge sampler originally developed for formaldehyde sampling (Waters Sep-Pak DNPH-silica cartridge), and the commercially available SKC UMEx 100 passive sampler originally developed for formaldehyde sampling. Aldehyde atmospheres for sampler evaluation were generated with an in-house made vapour atmosphere generator coupled to a sampling unit, with the possibility of parallel sampling. The resulting glyoxal-DNPH derivative was determined using both LC-UV and LC-APCI-MS with negative ionization. By far, the highest recovery of glyoxal was obtained employing one of the in-house DNPH coated silica samplers (93%, RSD = 3.6%, n = 12).  相似文献   

5.
Air sampling for (1 → 3)-β-D-glucan may be a good method for assessing inhalation exposure to airborne fungi. Pre-sampling contamination of filter media used for sampling (1 → 3)-β-D-glucan may lead to substantial exposure measurement errors. Using the Limulus amebocyte lysate assay, we tested for pre-sampling levels of (1 → 3)-β-D-glucan on three types of filters-mixed cellulose ester (MCE)[1 brand], glass fiber (GF)[1 brand], and polycarbonate (PC)[5 brands]. Levels of (1 → 3)-β-D-glucan on MCE filters exceeded 4586.1 pg per filter. Levels on GF filters averaged 135.3 (± 28.9) pg per filter (range = 94.8-160.4 pg per filter) and levels on PC filters averaged 152.4 (± 236.1) pg per filter (range = non-detectable-1760.7 pg per filter). Efforts to clean MCE and GF filters were unfeasible or unsuccessful. Sonicating PC filters for two hours in ethanol, followed by a wash in pyrogen-free water, effectively eliminated measured levels of (1 → 3)-β-D-glucan on four brands of PC filters, as compared to untreated PC filters. This pretreatment process did not appear to physically damage the PC filters. Air sampling results highlighted the potentially problematic contamination of untreated PC filters. Ensuring that sampling media are free of (1 → 3)-β-D-glucan before sampling is crucial to accurately measure levels of (1 → 3)-β-D-glucan exposure, especially in environments where levels of (1 → 3)-β-D-glucan are low.  相似文献   

6.
Personal aerosol samplers are widely used to monitor human exposure to airborne materials. For bioaerosols, interest is growing in analyzing samples using molecular and immunological techniques. This paper presents a personal sampler that uses a two-stage cyclone to collect bioaerosols into disposable 1.5 ml Eppendorf-type microcentrifuge tubes. Samples can be processed in the tubes for polymerase chain reaction (PCR) or immunoassays, and the use of multiple stages fractionates aerosol particles by aerodynamic diameter. The sampler was tested using fluorescent microspheres and aerosolized fungal spores. The sampler had first and second stage cut-off diameters of 2.6 microm and 1.6 microm at 2 l min(-1)(geometric standard deviation, GSD = 1.45 and 1.75), and 1.8 microm and 1 microm at 3.5 l min(-1)(GSD = 1.42 and 1.55). The sampler aspiration efficiency was >or=98% at both flow rates for particles with aerodynamic diameters of 3.1 microm or less. For 6.2 microm particles, the aspiration efficiency was 89% at 2 l min(-1) and 96% at 3.5 l min(-1). At 3.5 l min(-1), the sampler collected 92% of aerosolized Aspergillus versicolor and Penicillium chrysogenum spores inside the two microcentrifuge tubes, with less than 0.4% of the spores collecting on the back-up filter. The design and techniques given here are suitable for personal bioaerosol sampling, and could also be adapted to design larger aerosol samplers for longer-term atmospheric and indoor air quality sampling.  相似文献   

7.
A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 microg m(-3) and 1248 microg m(-3) were determined to be 91.2 +/- 3.9 ml min(-1) and 111.6 +/- 2.8 ml min(-1), respectively. The acetic acid sampling rate was independent of the concentration in the range 160 microg m(-3)-1564 microg m(-3), and amounted to 97.3 +/- 3.1 ml min(-1). Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 3-21% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 +/- 0.07 microg for formic acid and 1.21 +/- 0.14 microg for acetic acid, and detection limits lower than 0.5 microg m(-3) could be achieved, which is an improvement of 98-99% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.  相似文献   

8.
Low flow active sampling techniques collecting vapors and gases using thermally desorbable adsorbents are now feasible and desirable in many applications as they permit long integration times, the potential for miniaturized sampling configurations, and other advantages. At very low air flow rates (< 1 ml min(-1)), diffusive uptake on adsorbents in conventional sorbent tubes may equal or exceed the active (pumped) uptake rate, and even at low flow rates (1-4 ml min(-1)), diffusive uptake may significantly bias measurements. Thus, corrections to account for the diffusive flux or means to limit the diffusive uptake are needed in low flow applications. This paper presents (1) a theoretical analysis of the role of diffusive and advective uptake for several sampling geometries of tube-type samplers; (2) experimental confirmation using both laboratory and field studies; (3) estimates of the tortuosity and porosity of the glass wool packing used to retain the adsorbent, parameters needed to estimate diffusive fluxes in passive and active sampling; (4) a demonstration that orifice-equipped low flow active samplers can reduce diffusive uptake and improve precision, and (5) a model predicting the saturated adsorbent layer that helps to account for the gradual decline in uptake rates seen in passive sampling. Diffusive uptake will depend on the tube configuration and diffusion coefficient of the substance of interest, but for conventional sampling tubes (0.4-0.5 cm id, 1.5 cm air gap), sample flow rates should be maintained above 1 to 4 ml min(-1) to keep errors below 5%. Laboratory experiments showed close agreement with theoretical calculations, and the field study using 1 to 4 d sampling periods and 0.3 ml min(-1) flows demonstrated that the orifice-equipped samplers essentially eliminated diffusive uptake. No significant practical difficulties are encountered using orifices, e.g., pressure drop is minimal. Experimental estimates of tortuosity (0.79 +/- 0.02) and porosity (0.92 +/- 0.10) of the glass wool packing (0.3 cm length) represent relatively little resistance to diffusion; however, variation in the packing and adsorbent placement can degrade the precision achievable by passive samplers. Diffusion barriers, consisting most simply of an orifice, may be used to lower the diffusive uptake. A needle-type orifice permits flows below 0.1 ml min(-1) and is suitable for sampling periods as long as several weeks, and it provided greater precision than conventional open-ended sampling tubes (8% compared to 13%). Finally, the gradual decrease in diffusive fluxes often seen in passive sampling is attributed to additional resistance posed by a saturated adsorbent layer, in agreement with a simple model based on total VOCs and specific adsorptivity of the adsorbent.  相似文献   

9.
Exposure to various chemicals can cause adverse effects to health, such as asthma and allergies, especially in children. Data on personal exposure levels in children are scarce, thus small lightweight diffusive mini-samplers for aldehydes and volatile organic compounds (VOCs) were designed to measure the exposure level of children to these chemicals. The aim of the study was to validate and examine the applicability of these mini-samplers for measuring daily chemical exposure. The diffusive mini-samplers are 20 mm in length, 11 mm in diameter, and 1.67 g in weight. The devices are cylindrically shaped with polytetrafluoroethylene membrane filters placed at each end. To measure aldehydes and acetone, 20 mg of 2,4-dinitrophenylhydrazine was used as an absorbent. To measure VOCs, a carbon molecular sieve was used. The sampling rate for each chemical was determined by parallel sampling with active samplers in a closed exposure bag. The blank levels of the chemicals and the storage stability of the device were tested. The mini-samplers were compared to commercially available diffusive samplers. To examine the applicability of the samplers, 65 elementary school children carried them for 24 h. The sampling rates for formaldehyde, acetaldehyde, and acetone were 20.9, 22.9, and 19.7 mL min(-1), respectively. The limits of quantification (LOQ) for the 24-hour sampling by high-performance liquid chromatography/ultraviolet (HPLC/UV) analysis were 8.3, 7.6, and 8.8 μg m(-3) for formaldehyde, acetaldehyde, and acetone, respectively. The sampling rates for the 11 VOCs were determined and ranged from 3.3 mL min(-1) for styrene and 2-ethyl-1-hexanol to 11.7 mL min(-1) for benzene. The LOQ for the 24-hour sampling by gas chromatography-mass spectrometry (GC-MS) analysis ranged from 5.9-105.2 μg m(-3), 1.1-24.7 parts per billion. The storage stability after 5 days ranged from 94.8 to 118.2%. Formaldehyde, acetone, benzene, and toluene were detected above the LOQ in more than 90% of the children, and the median concentrations were 21.7, 20.9, 10.1, and 21.5 μg m(-3), respectively. This study shows that the diffusive samplers developed were suitable for children to carry and were capable of measuring the children's daily chemical exposure.  相似文献   

10.
Personal and area samples for airborne lead were taken at a lead mine concentrator mill, and at a lead-acid battery recycler. Lead is mined as its sulfidic ore, galena, which is often associated with zinc and silver. The ore typically is concentrated, and partially separated, on site by crushing and differential froth flotation of the ore minerals before being sent to a primary smelter. Besides lead, zinc and iron are also present in the airborne dusts, together with insignificant levels of copper and silver, and, in one area, manganese. The disposal of used lead-acid batteries presents environmental issues, and is also a waste of recoverable materials. Recycling operations allow for the recovery of lead, which can then be sold back to battery manufacturers to form a closed loop. At the recycling facility lead is the chief airborne metal, together with minor antimony and tin, but several other metals are generally present in much smaller quantities, including copper, chromium, manganese and cadmium. Samplers used in these studies included the closed-face 37 mm filter cassette (the current US standard method for lead sampling), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm Button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. The filters were analyzed after sampling for their content of the various metals, particularly lead, that could be analyzed by the specific portable X-ray fluorescence (XRF) analyzer under study, and then were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES). The 25 mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37 mm filters. For lead at the mine concentrate mill, all five samplers gave good correlations (r2 > 0.96) between the two analytical methods over the entire range of found lead mass, which encompassed the permissible exposure limit of 150 mg m(-3) enforced in the USA by the Mine Safety and Health Administration (MSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations without additional correction, indicating an absence of matrix effects from the presence of iron and zinc in the samples. An approximately 10% negative bias was found for the slope of the Button sampler regression, in line with other studies, but it did not significantly affect the accuracy as all XRF results from this sampler were within 20% of the corresponding ICP values. As in previous studies, the best results were obtained with the GSP sampler using the average of three readings, with all XRF results within 20% of the corresponding ICP values and a slope close to 1 (0.99). Greater than 95% of XRF results were within 20% of the corresponding ICP values for the closed-face 37 mm cassette using the OSHA algorithm, and the IOM sampler using a sample area of 3.46 cm2. As in previous studies, considerable material was found on the interior walls of all samplers that possess an internal surface for deposition, at approximately the same proportion for all samplers. At the lead-acid battery recycler all five samplers in their optimal configurations gave good correlations (r2 > 0.92) between the two analytical methods over the entire range of found lead mass, which included the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations (except for the Button sampler), indicating an absence of matrix effects from the presence of the smaller quantities of the other metals in the samples. A negative bias was found for the slope of the button sampler regression, in line with other studies. Even though very high concentrations of lead were encountered (up to almost 6 mg m(-3)) no saturation of the detector was observed. Most samplers performed well, with >90% of XRF results within +/- 25% of the corresponding ICP results for the optimum configurations. The OSHA algorithm for the CFC worked best without including the back-up pad with the filter.  相似文献   

11.
A study was undertaken, within the framework of a 3 years national project, to assess the content of 13 elements in airborne particulate matter collected in representative zones of the metropolitan area of Buenos Aires. The sampling strategy followed consisted in collecting simultaneously 67 samples of PM10 particulate matter in 9 sampling sites covering an area of about 30 km2 during one week. The collection was performed on ash-free fibre-glass filters using high volume samplers. A combination of aqua regia and perchloric acid was used for leaching metals from filters. Key elements, namely Al, Ca, Cu, Fe, Mn, Mo, Ni, Pb, S, Sb, Sn, Zn and Zr, were determined by inductively coupled plasma-optical emission spectrometry (ICP-OES) and inductively coupled plasma-mass spectrometry (ICP-MS) at micro g g(-1) and ng g(-1) levels. Analyte concentration varied from 130 ng g(-1)(Mo) to over 30%(Ca). Multivariate statistical analysis was performed on the data set including the measured elemental compositions for the monitored period. The atmospheric concentration found for Pb confirms the decreasing levels of this element since the introduction of unleaded gasoline in 1995: 88 ng m(-3)(2001) < 220 ng m(-3)(1997) < 3900 ng m(-3)(1994). The average S concentration above 3 microg m(-3) is somehow unexpectedly high for Buenos Aires since the relatively low S content of liquid fuels and the massive usage of natural gas imply low emissions of this element from combustion activities. To the best of our knowledge, S concentrations are reported for the first time for this city.  相似文献   

12.
The use of antineoplastic drugs in health care steadily increases. Health care workers can be occupationally exposed to antineoplastic drugs classified as carcinogenic or teratogenic. Monitoring of surface contamination is a common way to assess occupational exposure to antineoplastic drugs, since wipe sampling is used as a surrogate measure of dermal exposure. Since no occupational limits for antineoplastic drugs in work environments exist, 'hygienic guidance values' (HGVs) should be used instead. HGVs are practicable, achievable levels, not health based, and can be calculated from exposure data from representative workplaces with good occupational hygiene practices. So far, guidance values for surface monitoring of antineoplastic drugs only exist for pharmacies where antineoplastic drugs are prepared. The objective was to propose HGVs for surface monitoring of cyclophosphamide (CP) and ifosfamide (IF) in Swedish hospitals where antineoplastic drugs are administered to patients. In total, 17 workplaces located at six hospitals in Sweden were surveyed by wipe sampling. Wipe samples were collected, worked up and then analyzed with liquid chromatography tandem mass spectrometry. Surface contamination of CP and IF was found on 80% and 73% of the sampled surfaces, thus indicating that there is potential for health care workers to be exposed to CP and IF via the skin. The median surface load of CP was 3.3 pg cm(-2) (range <0.05-10,800 pg cm(-2)). The corresponding value for IF was 4.2 pg cm(-2) (range <0.13-95,000 pg cm(-2)). The highest surface loads were found on the floors. The proposed HGVs were set at 90th percentile values, and can be applicable to hospital workplaces where patients are treated with CP or IF. Surface monitoring combined with HGVs is a useful tool for health care workers to regularly benchmark their own surface loads which could control and reduce the occupational exposure to CP and IF in hospital workplaces. Thus, the occupational safety of the health care workers will be increased.  相似文献   

13.
The development of convenient and competitive devices and methods for monitoring of organic pollutants in the aquatic environment is of increasing interest. An integrative passive sampling system has been developed which consists of a solid poly(dimethylsiloxane) (PDMS) material (tube or rod), acting as hydrophobic organic receiving phase, enclosed in a water-filled or an air-filled low-density polyethylene (LDPE) membrane tubing. These samplers enable the direct analysis of the pollutants accumulated during exposure in the receiving phase by thermodesorption-GC/MS, avoiding expensive sample preparation and cleanups. The capabilities of these sampling devices were studied for the sampling of 20 persistent organic pollutants (chlorobenzenes, hexachlorocyclohexanes, p,p'-DDE, PAHs, and PCBs) in laboratory exposure experiments. For the three sampler designs investigated the uptake of all target analytes was integrative over exposure periods up to 9 days (except PCB 101). The determined sampling rates range from 4 to 1340 microl h(-1) for the water-filled samplers and from 20 to 6360 microl h(-1) for the air-filled ones, respectively. The sampling rate of the analytes is dependent on their molecular weight, partition between water and sampler media (PDMS, polyethylene, water, air) and also of the sampler design. The passive samplers enable the estimation of time-weighted average (TWA) concentration of water pollutants in the lower ng l(-1) to pg l(-1) range.  相似文献   

14.
The composition and variability of airborne fungal spores were studied using two complementary sampling methods in an outdoor environment in Kolkata suburb for 2 years, from November 2002 to October 2004. For monitoring the total fungal spore burden in the air, Burkard 7-day volumetric sampler was used, whereas Andersen two-sage viable sampler was used for isolating the cultivable airborne fungi. Among the 37 fungal spore types identified in the air samples, the predominant ones were Cladosporium, unidentified ascospores, unidentified basidiospores, Aspergilli/Penicilli, Nigrospora, Periconia, Chaetomium, Drechslera, Alternaria, Coprinus, Ganoderma, Pithomyces, and rust spores. Only six fungal spore types (Alternaria, Aspergilli/Penicilli, Cladosporium, Curvularia, Drechslera, and Nigrospora) were recovered in common by the two samplers. For Aspergilli/Penicilli, Drechslera, and Nigrospora, the spore concentration was underestimated in the non-viable sampling method (Burkard sampler). In general, higher spore count was recorded in winter. The highest fungal species variability was observed in early monsoon (June). Relative humidity could significantly predict the seasonal periodicity of the maximum number of airborne spores. The total airborne fungi concentration recorded in the study (15-16?×?10(3) spores m(-3) of air) was lower than the proposed threshold limit value for clinical significance, suggesting apparently no or less airborne-fungi-exposure-related health risk in the sampling area. Cladosporium cladosporioides was recorded beyond the proposed threshold limit value in January 2003 and March 2004; Aspergillus fumigatus and Aspergillus nidulans in winter that might have posed considerable health risk to sensitized individuals.  相似文献   

15.
Factors concerning NO2 uptake by the absorbent triethanolamine (TEA) in NO2 diffusion tubes are examined. Although the nominal freezing point of TEA is 17.9-21.2 degrees C, we show that, for a range of aqueous TEA solutions (0-20%, H2O), no freezing occurs even at -10 degrees C. Therefore NO2 collection efficiency is unlikely to be impaired by low temperature exposure. The recovery of TEA from the meshes of exposed samplers is determined as approximately 98%, even after 42 days, showing that the stability in situ of TEA is unaffected by long-term exposure. A model of a diffusion tube sampling array for simultaneous exposures, with a 0.1 m sampler spacing, shows that NO2 uptake by individual samplers is not affected by the presence of neighbouring tubes in the array. This is confirmed by sampler precision at two Cambridge sites. Four sampler preparation methods are compared for differences in NO2 uptake of exposed samplers. All methods employ TEA as absorbent, transferred by either dipping meshes in a TEA-acetone solution or pipetting aliquots of a TEA-H2O solution onto the meshes. For samplers prepared by three of the methods, no difference in NO2 uptake is found, but for samplers prepared using a 50% v/v TEA-H2O solution, a mean reduction of 18% is found. Student's t-tests show that the difference is highly significant (P < or = 0.001). Reasons for the difference are discussed.  相似文献   

16.
A number of methods are used to assess exposure to high-molecular weight allergens. In the occupational setting, airborne dust is often collected on filters using pumps, the filters are eluted and allergen content in the eluate analysed using immunoassays. Collecting inhalable dust using person-carried pumps may be considered the gold standard. Other allergen sampling methods are available. Recently, a method that collects nasally inhaled dust on adhesive surfaces within nasal samplers has been developed. Allergen content can be analysed in eluates using sensitive enzyme immunoassays, or allergen-bearing particles can be immunostained using antibodies, and studied under the microscope. Settling airborne dust can be collected in petri dishes, a cheap and simple method that has been utilised in large-scale exposure studies. Collection of reservoir dust from surfaces using vacuum cleaners with a dust collector is commonly used to measure pet or mite allergens in homes. The sampling methods differ in properties and relevance to personal allergen exposure. Since methods for all steps from sampling to analysis differ between laboratories, determining occupational exposure limits for protein allergens is today unfeasible. A general standardisation of methods is needed.  相似文献   

17.
In this study we performed a direct comparison between two different ambient air samplers to characterize their performance in sampling oxidized gaseous organic compounds, known as oxidation products of aromatics. We investigated compounds with a variety of functional groups and vapor pressures. A polyurethane foam (PUF) adsorbent and an annular diffusion denuder sampler were operated along with particle filters. In both systems the sampling devices were liquid-extracted, followed by derivatization and analysis by GC-MS. The PUF system works very well for aromatic as well as non-aromatic compounds, whereas the denuder shows smaller collection efficiencies for highly volatile non-aromatic compounds. In addition, the sampling efficiencies in the PUF set-up are in good agreement with the calculated vapor pressures of the compounds and also the particle phase is not affected by most compounds.  相似文献   

18.
Two types of passive sampler were developed for the long-term monitoring of semivolatile organic compounds (SOCs) in air. They consist of poly(dimethylsiloxane) (PDMS)-coated stir bars (type A) or silicone tubing (type B), acting as a solid receiving medium, enclosed in a heat-sealed low-density polyethylene (LDPE) membrane. These samplers combine the advantages of integrative passive sampling with those of analysing accumulated analytes by thermodesorption-GC-MS, whilst avoiding the use of solvents and expensive sample preparation and cleanup steps. The performance of these samplers was investigated for the integrative sampling of SOCs, including alpha- and gamma-hexachlorocyclohexanes, hexachlorobenzene, 2,4,4'-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl and fluoranthene, in laboratory exposure experiments under controlled conditions. For both types of sampler, the uptake of all the analytes investigated was linear over an exposure period of 15 days. The sampling rates calculated ranged from 70 to 320 ml h(-1) (sampler A) and 630 to 4300 ml h(-1) (sampler B). The passive samplers are able to detect low time-weighted average air concentrations in the pg m(-3) range. The small, robust and inexpensive sampling devices were tested successfully for the long-term air monitoring of semivolatile organic pollutants in a polluted area over an exposure period of up to 28 days.  相似文献   

19.
Mercury Vapor Determination in Hospitals   总被引:1,自引:0,他引:1  
The measurements of metallic mercury vapor were carried out in seven local hospitals, where mercury-containing products are widely used, as well as in one residence to check effectiveness of decontamination after mercury spillage. Hopcalite as a solid sorbent was used in active and passive sampling methods, and mercury was analyzed by CV-AAS technique. Good agreement was found between results of mercury measurements using active samplers (pumped hopcalite adsorption tubes) and passive (diffusion) monitors applied in indoor atmosphere. The results indicated the presence of metallic mercury vaporization sources in the assessed hospital rooms but in the majority of cases mercury levels did not exceed 1 g/m3 i.e. Polish permissible concentration for residence. However, in some of the hospital rooms, elevated concentrations of mercury vapor were found and airborne levels of up to 13.9 g/m3 were recorded. Higher concentrations of mercury vapor were observed in autumn season when compared to summer.  相似文献   

20.
Diffusive sampling of Volatile Organic Compounds (VOCs) onto thermal desorption tubes, followed by gas chromatography, is an established technique for area or personal monitoring of typical workplace concentrations and there has been increasing interest in extending the application to environmental levels, particularly for benzene, toluene and xylene (BTX). Diffusive sampling rates for BTX on Chromosorb 106 and Carbograph-1 (a graphitised carbon) were measured over periods of 1-4 weeks in field validation experiments using ambient air and parallel pumped sampling (the reference method) at the HSL site in central Sheffield. The reference method was also used to investigate the possible bias of an open-path spectrophotometer (OPSIS) used by Sheffield City Council. A bias for BTX was suspected from results of a two-week initial exercise in which several diffusive samplers were placed close to the light path. In the full field validation of the diffusive samplers carried out subsequently, the significant bias of BTX concentrations reported by OPSIS were confirmed when compared with concurrent results from the reference method. OPSIS gave benzene and toluene values up to eight times higher than expected from the GC measurements. Xylene discrepancies were smaller, but in one 3-day peak episode, OPSIS demonstrated a negative correlation with GC.  相似文献   