首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Measurements of indoor radon concentrations were performed in 28 low-rise houses and 30 apartments in Patras area from December 1996 to November 1997, using nuclear track detectors. The investigation was focused on the effects of season and floor number, as well as on the existence of a basement in low-rise houses on indoor radon levels. It was found that the differences in mean radon concentrations between adjacent seasons, in a number of 61 selected sampling sites distributed in 28 houses, were statistically significant. As expected, a maximum was found in winter and a minimum in summer. The differences in mean radon concentration on different floors of the same houses were also statistically significant and followed a linear decrease from underground to 2nd floor. In addition, indoor radon concentrations in the ground floor were found to be influenced by the existence or not of a basement. The average annual radon concentration was found to be 41 Bq m(-3) for the houses, 28 Bq m(-3) for the apartments and 38 Bq m(-3) for all the dwellings. These values lead to an average effective dose equivalent of 1.1, 0.7 and 0.9 mSv y(-1), respectively. Residents living on the underground in low-rise houses, during winter, where the average effective dose equivalent is 2.1 mSv y(-1), attain the higher risk.  相似文献   

2.
The indoor air of 60 residences in and around a Maryland suburb of Washington, DC, was monitored in a pilot study to determine residential radon concentrations. In each residence, a radon grab sample was acquired in the living room, and, if possible, in the basement. Infiltration rates were determined by tracer gas dilution. To help standardize sampling conditions, each home remained closed up for 8 h prior to sampling and during analysis. Over 60% of the residences sampled showed air infiltration rates below 0.6 air changes per hour. Approximately 55% of all surveyed basements and 30% of all surveyed living areas displayed radon concentrations in excess of 4.0 nCi m−3. Assuming an equilibrium factor of 0.5, these radon levels may lead to working levels above the annual guidelines suggested by EPA for florida homes build on land reclaimed from phosphate mining.  相似文献   

3.
The aim of this work was to make a comparison of indoor radon concentrations in dwellings and in soil air in the area of two geological formations in the Suwa?ki region (Poland). The mean arithmetic airborne concentration was found to be the highest (301 Bq m (-3)) in the basements of buildings in the gravel and sand areas, whereas in the boulder clay areas it reached 587 Bq m (-3). Out of 54 measurements of radon concentrations performed at the ground floor, in eight cases concentrations were found to exceed 200 Bq m (-3) - permissible radon level in new-built houses in Poland and in three cases these values were even higher than 400 Bq m (-3). The highest radon levels were noted in houses with earthen basement floors and with direct entrance from the basement to rooms or kitchens. The mean arithmetic radon concentration in the soil air in the sandy and gravel formations was 39.7 kBq m (-3) and in clay formation it was 26.5 kBq m (-3). Higher radon levels were also found in the water obtained from household wells reaching 8367 Bq m (-3) as compared with tap water (2690 Bqm (-3)). The mean indoor concentration for the whole area under study was found to be 169.4 Bq m (-3), which is higher than the mean value for Poland (49.1 Bq m (-3)) by a factor of 3.5.  相似文献   

4.
We propose a new methodology for predicting areas with a strong potential for radon (222Rn) exhalation at the soil surface. This methodology is based on the Rn exhalation rate quantification, starting from a precise characterisation of the main local geological and pedological parameters that control the radon source and its transport to the soil/atmosphere interface. It combines a cross mapping analysis of these parameters into a geographic information system with a model of the Rn vertical transport by diffusion in the soil. The rock and soil chemical and physical properties define the entry parameters of this code (named TRACHGEO) which calculates the radon flux density at the surface. This methodology is validated from in situ measurements of radon levels at the soil/atmosphere interface and in dwellings. We apply this approach to an area located in western France and characterised by a basement displaying a heterogeneous radon source potential, as previously demonstrated by lelsch et al. (J. Environ. Radioactivity 53(1) (2001) 75). The new results obtained show that spatial heterogeneity of pedological characteristics in addition to basement geochemistry--must be taken into account to improve the mapping resolution. The TRACHGEO forecasts explain the Rn exhalation variability on a larger scale and in general correlate well with in situ observations. Moreover, the radon-prone sectors identified by this approach generally correspond to the location of the dwellings showing the highest radon concentrations.  相似文献   

5.
Although United Kingdom (UK) Building Regulations applicable to houses constructed since 1992 in Radon Affected Areas address the health issues arising from the presence of radon in domestic properties and specify the installation of radon-mitigation measures during construction, no legislative requirement currently exists for monitoring the effectiveness of such remediation once construction is completed and the houses are occupied. To assess the relative effectiveness of During-Construction radon reduction and Post-Construction remediation, radon concentration data from houses constructed before and after 1992 in Northamptonshire, UK, a designated Radon Affected Area, was analysed. Post-Construction remediation of 73 pre-1992 houses using conventional fan-assisted sump technology proved to be extremely effective, with radon concentrations reduced to the Action Level, or below, in all cases. Of 64 houses constructed since 1992 in a well-defined geographical area, and known to have had radon-barrier membranes installed during construction, 11% exhibited radon concentrations in excess of the Action Level. This compares with the estimated average for all houses in the same area of 17%, suggesting that, in some 60% of the houses surveyed, installation of a membrane has not resulted in reduction of mean annual radon concentrations to below the Action Level. Detailed comparison of the two data sets reveals marked differences in the degree of mitigation achieved by remediation. There is therefore an ongoing need for research to resolve definitively the issue of radon mitigation and to define truly effective anti-radon measures, readily installed in domestic properties at the time of construction. It is therefore recommended that mandatory testing be introduced for all new houses in Radon Affected Areas.  相似文献   

6.
Radon concentrations in dwellings vary by more than two orders of magnitude. Predicting where and when concentrations are likely to be high requires studying the variability of the contributors to radon in buildings. Among common sources, geological factors (water supply and substrate) are the most variable, whereas building materials are much less variable. Ventillation variation among houses is generally responsible for radon variations comparable to those introduced by building materials, but it is more significant at lower ventilation rates. In some regions with relatively high proportions of houses with elevated radon concentrations, mappable geological factors are associated with most cases of high radon concentrations. However, a priori identification of rock types likely to be implicated is likely to be successful in only a few cases.  相似文献   

7.
Active soil ventilation techniques have been tested in 26 block-wall basement houses in eastern Pennsylvania with significantly elevated indoor radon concentrations, generally above 740 Bq/m3, and the results indicate that radon levels can be reduced substantially often below the U.S. Environmental Protection Agency (EPA) guideline of 148 Bq/m3, if effective suction can be drawn on the soil underneath the concrete slabs of these houses. Such effective suction appears achievable when either: 1) the house has a complete loop of drain tile around its footings for water drainage purposes, and suction is drawn on that loop; or 2) a sufficient number of suction pipes can be inserted at the proper locations into the crushed rock or the soil underneath the slab.  相似文献   

8.
This paper reports the results of indoor radon measurements carried out in the Lombard plain. The aim of this study, which is based on the geological context, was to identify radon high-risk areas. The underlying geology has been established by means of the available stratigraphies giving a schematic representation of the sites in which either occurrence of gravel or silt and clay predominate with depths ranging from 0 to 50 m. Radon measurements were performed in a sample of 411 one-family houses in seven villages located in the southern area of Bergamo and Brescia. The findings indicate that when the substrate is dominated by clay, radon concentration for dwellings on the ground floor are low, whereas a strong predominance of underlying gravel mixed up in sand gives in winter months high radon flux from underground.  相似文献   

9.
Radon gas contributes a significant fraction of the natural background radiation dose, and in some areas raised levels are found in buildings. both homes and the workplace. Different UK Action Levels apply to homes and the workplace. because of the diurnal variation of radon. This study reviews the results for a number of hospitals throughout England and Wales. and suggests that the likelihood of finding raised radon levels is similar in the workplace and homes in the same area. Radon measurements and consequent remediation of any raised levels are appropriate in all workplaces in radon Affected Areas with over 5% of houses above the UK domestic Action Level of 200 Bq m(-3).  相似文献   

10.
The present paper discusses the results of an empirical study of four approaches to reducing indoor radon concentrations based on depressurization techniques in underground sumps. The experiments were conducted in prototype housing built in an area of Spain where the average radon concentration at a depth of 1 m is 250 kBq m−3.Sump effectiveness was analysed in two locations: underneath the basement, which involved cutting openings into the foundation, ground storey and roof slabs, and outside the basement walls, which entailed digging a pit alongside the building exterior. The effectiveness of both sumps was likewise tested with passive and forced ventilation methods.The systems proved to be highly efficient, lowering radon levels by 91-99%, except in the solution involving passive ventilation and the outside sump, where radon levels were reduced by 53-55%. At wind speeds of over 8 m/s, however, passive ventilation across an outside sump lowered radon levels by 95% due to a Venturi effect induced drop in pressure.  相似文献   

11.
In solar rockbed storage systems, heat is transferred during the day from the collector to a bed of pebbles, and released at night to warm the living space. When the rocks used for storage contain significant concentrations of uranium, 222Rn and its daughters may be released to the living area. A microcomputer model was used to simulate variations in air filtration rate and source strength through several days of operation. Source strengths were estimated from theoretical considerations and literature data. Resulting 222Rn and daughter concentrations were computed by solving system equations by fourth-order Runge-Kutta integration. During the day, when the living space is isolated from the radon source, interior 222Rn concentrations approach those of the outdoors. A nighttime steady-state concentration is approached about 6 h after heat discharge begins. Due to the dynamic nature of the simulation, equilibrium between 222Rn and its daughters is not reached. Time-weighted average nighttime exposures (6 p.m.–8 a.m.) for 10 simulation runs varied from 0.001 to 0.018 working level (WL). Comparison with one set of measurement data showed the model to overpredict concentrations but to approximate the 222Rn buildup rate well. Combinations of source strength, infiltration rate, and exterior radon concentration which would lead to exposures exceeding 0.02 WL were calculated.  相似文献   

12.
Forty measurements are reported in similar rooms in two high-rise buildings. The geometrical means for the concentration of radon daughters including and excluding the basement results, respectively, were 0.90 and 1.00 mWL, which is less than the quoted mean 2.0 mWL for 65 measurements in typical houses in the same city. The frequency distribution of these measurements shows a log-normal distribution. The concentrations did not depend on the distance from ground level but may depend on the ventilation rate of the room examined. The correlation between the concentration of radon daughters in WL in rooms above the first floor in the two high-rise buildings with the inverse of their ventilation rate were 0.73 and 0.67, respectively.  相似文献   

13.
Environmental radon exposure of residents of domestic premises in the United Kingdom (UK) and elsewhere in Europe is estimated on the basis of the measured radon concentrations in, and the relative occupancies of, the principal living room and bedroom. While studies on radon concentration variability in the individual units in apartment blocks in various countries have been described, little data has been reported on variability in two-storey single-family dwellings, and the majority of extant studies consolidate living room and bedroom data early in the analysis. To investigate this further, detailed analysis was made of radon concentration data from a set of thirty-four homes situated in areas of Northamptonshire known to exhibit high radon levels. All homes were of typical UK construction of brick/block/stone walls under a pitched tile/slate roof. Approximately 50% of the sample were detached houses, the remainder being semi-detached (duplex) or terraced (row-house). Around 25% of the sample possessed cellars, while 12% were single-storey dwellings (bungalows), reflecting the typical incidence of this type of dwelling in England. In the two-storey homes, all monitored bedrooms were on the upper floor. Distribution of the ratios of bedroom/living room radon concentrations (BR/LR ratio) in individual properties was left-skewed (mean 0.67, median 0.73, range 0.05-1.05) with a tail extending to just above 1.0. The mean is consistent with the outcome of earlier extensive studies in England, while the variability depends principally on the characteristics of the property, and not on seasonal factors. In a small set of homes, the BR/LR ratio was anomalously low, (mean 0.3). BR/LR ratios in single-storey homes clustered around a value of 1.0, indicating that house design, rather than lifestyle, is the dominant factor in determining bedroom radon concentrations. Homes with higher mean annual radon concentrations showed lower BR/LR ratios, supporting our proposal that, in some homes, radon emanation from building materials may comprise a significant component of the overall radon level.  相似文献   

14.
In ten high radon level kindergartens, radon sources were sought by applying a combination of several radon measuring techniques: etched track detectors to obtain average indoor air radon concentration, continuous devices to record radon concentration and see its diurnal variation, and alpha scintillation cells to determine radon concentration in the air entering a room from cracks, holes and sinks in the floor and from under-floor channels. In three cases, a strong local radon source was identified while, in the others, the bad quality of the basic concrete slab was responsible for the high indoor radon concentration.  相似文献   

15.
A radon survey has been carried out around the town of Niska Banja (Serbia) in a region partly located over travertine formations, showing an enhanced level of natural radioactivity. Outdoor and indoor radon concentrations were measured seasonally over the whole year, using CR-39 diffusion type radon detectors. Outdoor measurements were performed at 56 points distributed over both travertine and alluvium sediment formations. Indoor radon concentrations were measured in 102 living rooms and bedrooms of 65 family houses. In about 50% of all measurement sites, radon concentration was measured over each season separately, making it possible to estimate seasonal variations, which were then used to correct values measured over different periods, and to estimate annual values. The average annual indoor radon concentration was estimated at over 1500 Bq/m3 and at about 650 Bq/m3 in parts of Niska Banja located over travertine and alluvium sediment formations, respectively, with maximum values exceeding 6000 Bq/m3. The average value of outdoor annual radon concentration was 57 Bq/m3, with a maximum value of 168 Bq/m3. The high values of indoor and outdoor radon concentrations found at Niska Banja make this region a high natural background radiation area. Statistical analysis of our data confirms that the level of indoor radon concentration depends primarily on the underlying soil and building characteristics.  相似文献   

16.
Significantly elevated radon concentrations were found in several adjacent houses in Clinton, New Jersey. The United States Environmental Protection Agency screened 56 of the houses and selected 10 for demonstration of radon-reduction techniques. Each of the 10 houses received an intensive radon diagnostic evaluation before a house-specific radon reduction plan was developed. Depressurization effects caused by temperature differentials and the operation of mechanical equipment were quantified. Before and after radon reduction plans were implemented, radon concentrations were determined by charcoal canisters and continuous radon monitors. A variety of sealing and subslab depressurization techniques were applied to the 10 houses. Radon concentrations were reduced by over 95% in all 10 houses. The cost of applying radon reduction techniques ranged from $1500 to $8500 per house. House construction characteristics were described which contributed to the high cost of radon reduction. In summary, the 10-house radon reduction demonstration in Clinton, New Jersey was successful in showing homeowners with similar house types some effective ways of reducing radon concentrations.  相似文献   

17.
In the beginning of 1990s within the framework of a national radon survey of more than 1500 points, radon measurements were performed in more than 100 houses located in Galicia region, in the Northwest area of Spain. The houses were randomly selected only bearing in mind general geological aspects of the region. Subsequently, a nationwide project called MARNA dealt with external gamma radiation measurements in order to draw a Spanish natural radiation map. The comparison in Galicia between these estimations and the indoor radon levels previously obtained showed good agreement. With the purpose of getting a confirmation of this relationship and also of creating a radon map of the zone, a new set of measurements were carried out in 2005. A total of 300 external gamma radiation measurements were carried out as well as 300 measurements of (226)Ra, (232)Th and (40)K content in soil. Concerning radon, 300 1-m-depth radon measurements in soil were performed, and indoor radon concentration was determined in a total of 600 dwellings. Radon content in soil gave more accurate indoor radon predictions than external gamma radiation or (226)Ra concentration in soil.  相似文献   

18.
Radon concentrations were continuously measured outdoors, in the living room and in the basement at 10 min intervals for a month. Radon time series were analyzed by comparing algorithms to extract phase space dynamical information. The application of fractal methods enabled exploration of the chaotic nature of radon in atmosphere. The computed fractal dimensions, such as the Hurst exponent (H) from the rescaled range analysis, Lyapunov exponent (lambda) and attractor dimension, provided estimates of the degree of chaotic behavior. The obtained low values of the Hurst exponent (0 < H < 0.5) indicated anti-persistent behavior (non-random changes) of the time series, but the positive values of lambda pointed out the grate sensitivity on initial conditions and the deterministic chaos that appeared due to radon time variations. The calculated fractal dimensions of attractors indicated more influencing (meteorological) parameters on radon in the atmosphere.  相似文献   

19.
Monitoring of radon, thoron and their daughter products was carried out in houses of Kumaun Himalaya, India using LR-115 plastic track detectors. The measurements were made in residential houses from June 1999 to May 2000 at a height of 2.5 m from ground level using a twin chamber radon dosimeter. The twin chamber radon dosimeter can record the values of radon, thoron and their decay products separately. Maximum and minimum indoor radon and thoron concentrations were evaluated and activity concentrations of radon and thoron daughters were estimated. The resulting dose rates due to radon, thoron and their decay products varied from 0.04 to 1.89 microSv/h. A detailed analysis of the distribution of radon, thoron and their decay products inside the house is also reported. The observed dose rates inside the houses of Kumaun Himalaya were found to be lower than the ICRP recommended value of 200 Bq/m3 and thus are within safe limits.  相似文献   

20.
Sweden introduced limits and gave recommendations for decreasing the indoor radon daughter concentrations in 1980. The resulting experiences are summarized. From 1979 to 1987, measurements were carried out by the local authorities in about 58 000 out of 3.9 million homes in Sweden, and 5300 homes were found to have levels exceeding the limit for existing houses, or 400 Bq/m3 of equilibrium equivalent concentration of radon (EER). This may be about 13% of the estimated 40 000 homes with levels exceeding 400 Bq/m3. Very high levels, up to 28 000 Bq/m3, have been found. According to the local authorities, in one third of the homes found with levels exceeding the limit (1921 homes) certain reconstruction and other measures have been taken in order to decrease the levels. In reality, measures have been carried out in more houses. The methods depend on the radon source. The average reductions found for respective methods are reported. The local authorities can require a check of the radon daughter concentrations in newly built houses when they suspect that the concentrations exceed the limit of 70 Bq/m3. In 11% of the measured homes built during 1981 to 1985, the levels were above the limit for newly built houses. In 1.4% of these houses, the limit for existing houses, 400 Bq/m3, had been exceeded. The strategy to decrease both the collective dose to the population and the individual dose is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号