首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
Precipitation scavenging of particles is a major mechanism for atmospheric deposition of organic contaminants, but there have been few field studies. We studied precipitation scavenging of PCDD/Fs with the aim of deepening understanding of environmental variables influencing this process. Bulk deposition of PCDD/Fs and their concentrations in ambient air measured at a background site in Sweden were used to calculate precipitation scavenging ratios. Contrary to expectations, increasing scavenging ratios with decreasing degree of chlorination of the PCDD/F congeners were observed when the particle-associated PCDD/F concentrations in air were used for the calculation. This was attributed to differences in temperature and thereby in the gas – particle partitioning of the PCDD/Fs between ground level and clouds where much of the particle scavenging occurs. When the particle-associated PCDD/F concentrations were recalculated for a 10–20 °C lower temperature, the scavenging ratios of the different PCDD/F congeners were similar. Hence differences between ground level and in-cloud temperature should be considered when calculating scavenging ratios from field observations and when modeling this process. The scavenging ratios averaged ~200 000, with lower values when the particle-associated PCDD/F concentration in air was lower. The soot concentration in air was a good predictor of bulk deposition of PCDD/Fs.  相似文献   

2.
Ambient air monitoring of PCDD/Fs and co-PCBs in Gyeonggi-do, Korea   总被引:3,自引:0,他引:3  
Kim DG  Min YK  Jeong JY  Kim GH  Kim JY  Son CS  Lee DH 《Chemosphere》2007,67(9):1722-1727
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis).  相似文献   

3.
Xu MX  Yan JH  Lu SY  Li XD  Chen T  Ni MJ  Dai HF  Cen KF 《Chemosphere》2008,71(6):1144-1155
Isomer-specific data were investigated in order to identify the sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in agricultural soils, including Fluvo-aquic and paddy soils, in the vicinity of a Chinese municipal solid waste incineration (MSWI) plant. Homologue and isomer profiles of PCDD/Fs in soils were compared with those of potential sources, including combustion sources, i.e., MSWI flue gas and fly ash; and the impurities in agrochemicals, such as the pentachlorophenol (PCP), sodium pentachlorophenate (PCP-Na) and 1,3,5-trichloro-2-(4-nitrophenoxy) benzene (CNP). The results showed that the PCDD/F isomer profiles of combustion sources and agricultural soils were very similar, especially for PCDFs, although their homologue profiles varied, indicating that all the isomers within each homologue behave identically in the air and soil. Moreover, factor analysis of the isomer compositions among 33 soil samples revealed that the contamination of PCDD/Fs in agricultural soils near the MSWI plant were primarily influenced by the combustion sources, followed by the PCP/PCP-Na and CNP sources. This implication is consistent with our previous findings based on chemometric analysis of homologue profiles of soil and flue gas samples, and identifies PCP/PCP-Na as an additional important source of PCDD/Fs in the local area. This makes the similarities and differences of isomer profiles between Fluvo-aquic and paddy soils more explainable. It is, therefore, advisable to use isomer-specific data for PCDD/F source identifications where possible.  相似文献   

4.
PCDD/F analyses were made in soil and ambient air samples taken from Kocaeli, an industrialized area of Turkey. Results showed that the levels of PCDD/F pollution are comparable to the levels observed in the various urban areas in the world. PCDD/F concentrations in surface soils ranged between 0.4 and 4.27 pg I-TEQ kg(-1) with a geometric mean of 0.76 pg I-TEQ kg(-1), while those in ambient air were between 23 and 563 f gm(-3), with geometric mean of 82.0 f gm(-3). Ambient air PCDD/F concentration in the city center was about 10 times higher than those in the rural area. Combustion activities present in the area were assessed to be the most significant source of the PCDD/F pollution based on the congener and homologue profiles and statistical analysis of the data. The deposition rate modeling of USEPA was applied and the deposition rates were determined in the range between 7.6 and 66.3 ng I-TEQ m(-2)year(-1) with a geometric mean of 15.9 ng I-TEQ m(-2)year(-1). The rates were higher than the recommended deposition rates in relation to the tolerable daily intake (TDI) range of PCDD/Fs for humans. The deposition velocities computed were also found to be high in both low and highly chlorinated PCDD/Fs, and this was attributed to the vapor phase deposition of volatile PCDD/Fs, and the scavenging effect of the precipitation on the particle-bound PCDD/Fs.  相似文献   

5.
Fang M  Choi SD  Baek SY  Park H  Chang YS 《Chemosphere》2011,84(7):894-899
An IRA-743 resin bulk sampler was validated to monitor long-term bulk deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Six consecutive sampling campaigns (2008-2009) were conducted at four sites around steel complexes in Pohang, South Korea to investigate spatial and seasonal variations of PCDD/F bulk deposition. The bulk deposition within the steel complex showed the highest ∑4-8PCDD/F (Tetra-Octa) fluxes, ranging from 204 to 608 (mean: 352) pg m−2 d−1, indicating steel complexes were major sources of PCDD/Fs. The homologue profiles were dominated with lower chlorinated PCDFs. Furthermore, the prevailing winds were confirmed to influence the spatial distribution of PCDD/F deposition. There were apparent seasonal variations of the bulk deposition at each site, and seasonal homologue patterns of PCDD/Fs were clearly observed. According to the passive air sampling, however, no significant seasonal change of ambient air concentrations of PCDD/Fs was observed. Therefore, it was concluded that the seasonal variations of deposition fluxes of PCDD/Fs probably resulted from temperature-dependent gas/particle partitioning.  相似文献   

6.
PCDD/F contamination of the Baltic Sea has resulted in the European Union imposing restrictions on the marketing of several fish species. Atmospheric deposition is the major source of PCDD/Fs to the Baltic Sea, and hence there is a need to identify the source regions of the PCDD/Fs in ambient air over the Baltic Sea. A novel monitoring strategy was employed to address this question. During the winter of 2006–2007 air samples were collected in Aspvreten (southern Sweden) and Pallas (northern Finland). Short sampling times (24 h) were employed and only samples with stable air mass back trajectories were selected for analysis of the 2,3,7,8-substituted PCDD/F congeners. The range in the PCDD/F concentrations from 40 samples collected at Aspvreten was a factor of almost 50 (range 0.6–29 fg TEQ/m3). When the samples were grouped according to air mass origin into seven compass sectors, the variability was much lower (typically less than a factor of 3). This indicates that air mass origin was the primary source of the variability. The contribution of each sector to the PCDD/F contamination over the Baltic Sea during the winter half year of 2006/2007 was calculated from the average PCDD/F concentration for each sector and the frequency with which the air over the Baltic Sea came from that sector. Air masses originating from the south–southwest, south–southeast and east segments contributed 65% of the PCDDs and 75% of the PCDFs. Strong correlations were obtained between the concentrations of most of the PCDD/F congeners and the concentration of soot. These correlations can be used to predict the PCDD/F concentrations during the winter half year from inexpensive soot measurements.  相似文献   

7.
Sampling and analysis of ambient dioxins in northern Taiwan   总被引:2,自引:0,他引:2  
Chang MB  Weng YM  Lee TY  Chen YW  Chang SH  Chi KH 《Chemosphere》2003,51(10):1103-1110
In this study, ambient air samples were taken concurrently in the vicinity area of a large-scale municipal waste incinerator (MWI) and the background area for measuring polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) concentrations from November 1999 through July 2000 in northern Taiwan. The results obtained from eighteen ambient air samples indicate that the mean PCDD/F concentration of seventeen 2,3,7,8-substituted congeners in wintertime (188–348 fg-I-TEQ/m3) is significantly higher than that measured in summertime (56–166 fg-I-TEQ/m3). In addition, the seasonal PCDD/F concentrations are compared with the ambient air quality data including CO, NO2, PM10 and TSP sampled from Taipei area to gain better insights. It indicates that the variation of ambient air PCDD/F concentrations is closely correlated with that of PM10 concentrations. Besides, the results indicate that the I-TEQ concentration of ambient air in sampling site B (directly downwind of the MWI) is of the highest while the sampling site A (upwind of MWI) is of the lowest among all sampling sites. This implies that existing MWI can be a significant emitter of PCDD/Fs in this area. Furthermore, the patterns of the PCDD/F congener distribution at all sampling sites (including the background site in Taoyuan) are quite similar. OCDD concentration is of the highest among seventeen PCDD/F congeners investigated and accounts for about 35% of the total concentration. As for the I-TEQ concentrations, 2,3,4,7,8-PeCDF is the most significant contributor, generally being responsible for 30–45% of the total I-TEQ values depending on the sampling sites and seasons.  相似文献   

8.
Pan J  Yang YL  Chen DZ  Xu Q  Tang H  Li Y  Nie LM  Jiang K  Xi DL 《Chemosphere》2008,70(9):1699-1706
Seven of surface sediments, one sediment core and two mussel samples were collected from the Qingdao coastal sea of the western Yellow Sea and analyzed to determine the horizontal distribution, deposition flux, and toxicity equivalency (TEQs) of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The total PCDD/Fs concentrations in the surface sediments ranged between 10.7 and 428 ng kg(-1) dry wt. The horizontal distribution of PCDD/F congeners in the sediments was characterized by elevated concentrations at the locations in the east of Jiaozhou Bay with the highest concentration occurring near the Haibo River mouth. Physical parameters (total organic carbon contents and sediment types) and the current circulation systems in Jiaozhou Bay can be important factors controlling the horizontal distribution pattern of PCDD/Fs in the bay. The influence of the Haibo River as a source of pollution was evidenced by PCDD/F homologue profiles, indicating a contribution from sewage sludge in addition to other possible sources. Records from the sediment core revealed that the total PCDD/Fs in the Qingdao coastal sea were nearly constant since 1951 till 1980s and increased remarkably after 1980s. The total 2,3,7,8-substituted PCDD/Fs and total TEQs of PCDD/Fs on the lipid basis in the mussel sample inside the bay were significantly higher than in the adjacent sediment. The homologue profiles of PCDD/Fs in the mussels were quite different from those of the sediments, characterized by high TCDF (50% of the total PCDD/Fs).  相似文献   

9.
Floret N  Lucot E  Badot PM  Mauny F  Viel JF 《Chemosphere》2007,68(8):1419-1426
Since 1971, a municipal solid waste incinerator (MSWI) with high dioxin emission levels has been in operation in Besan?on, France. We recently found a 2.3-fold risk of non-Hodgkin's lymphoma in the highest exposure zone using a Gaussian-type dispersion model as a proxy for dioxin exposure. However, the sources of PCDD/Fs in this area are a matter of controversy. The aim of this survey was therefore to examine the nature of the PCDD/F soil contamination in the surroundings of the MSWI to characterize whether more than one potential emission source could explain the presence of the PCDD/Fs. PCDD/F congener profiles were determined in 75 soil samples collected in the vicinity of the MSWI. They were compared according to the most environmentally impacted zones and to various spatial contrasts. PCDD/F concentrations ranged from 0.25 to 28.06 pg WHO-TEQ g(-1). Two different clustering algorithms identified the same main cluster (consisting of 73 samples). The remaining two soil samples composed either one, or two clusters. All clusters showed similar congener profiles. Moreover, no contrast was observed for congener distributions between complex and simple topographies, inside and outside the city boundary, the two most and the two least exposed areas, reflecting a common fingerprint. Congener profiles indicate that the area under influence of the MSWI is not subject to other point sources of PCDD/Fs. Since, the most polluting combustion chambers were recently shut down and replaced by a new one with up-to-date pollution control, slowly decreasing dioxin concentrations in the soils are to be expected.  相似文献   

10.
Kymijoki, the fourth largest river in Finland, has been heavily polluted by pulp mill effluents as well as the chemical industry. Up to 24,000 ton of wood preservative, chlorophenol known as Ky-5, was manufactured in the upper reaches of the river, an unknown amount of which was discharged into the river between 1940 and 1984. Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) occurred as impurities in the final Ky-5 product. The PCDD/F concentrations and burden in the river sediments were studied and the transport of PCDD/Fs from contaminated sites downstream and into the Gulf of Finland in the Baltic Sea was estimated. More than 190 sediment cores were sampled to estimate the volume of contaminated sediments and the total PCDD/F burden. The transport of PCDD/Fs was estimated using sediment traps placed at several sites. The survey revealed that sediments in the river were heavily polluted by PCDD/Fs, the main toxic congener being 1,2,3,4,6,7,8-heptachlorodibenzofuran, a major contaminant in the Ky-5 product. The mean total concentration at the most polluted river site downstream from the main source was 42000 microg kg(-1) d.w. (106 microg I-TEQ kg(-1)). The elevated concentrations in the coastal region and the present estimated transport from the River Kymijoki confirm earlier assessments that the river is a major source of PCDD/F for the Gulf of Finland.  相似文献   

11.
This study was designed to evaluate soil and air (gas and particle) transfer of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to vegetation in residential and industrial areas. In a first part, soil-vegetation transfer was assessed. The levels of PCDD/Fs in 120 soil and 120 herbage samples collected from 1996 to 2002 in an industrial area of Montcada (Barcelona, Spain), near a municipal solid waste incinerator (MSWI), were determined. Some additional individual samples were also evaluated. It was concluded that high soil concentrations, which are not at steady state with the air layer above it, show a tendency for PCDD/Fs to escape via volatilization. In a second part of the study, air-vegetation transfer was examined. PCDD/F concentrations from 24 herbage samples were used, while PCDD/F concentrations were also measured in seven high-volume air samples and seven passive air-vapor samples. Scavenging coefficients (m3 air "sampled"/g grass d.m.) ranged from 1.9 to 11.3 m3/g. A good trend with K(OA) was observed for PCDDs (R=0.82), while it was lower for PCDFs (R=0.55). The current results corroborate that PCDD/F concentrations in vegetation are associated with atmospheric deposition. For the highest substituted PCDD/F congeners, the air-particle uptake from plants is the principal pathway. In regions impacted by combustion emission sources, PCDD/F gas-particle partitioning is influenced by a higher concentration of particles in the air. Particles and associated particle-bound PCDD/Fs would sorb to leaf surfaces, and are subject to removal via wash off. However, in areas where emissions to air are not very notable, vapor absorption would be the principal source of vegetation pollution. The results of this investigation can have a potential interest in risk assessment studies and environmental fate models.  相似文献   

12.
Cheng PS  Hsu MS  Ma E  Chou U  Ling YC 《Chemosphere》2003,52(9):1389-1396
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in twenty-one ambient air samples, eight soil samples and two stack gas samples, collected near or in a municipal solid waste incinerator (MSWI) in Hsinchu, Taiwan. A systematic decrease of PCDD/Fs in the ambient air from the northeastern area was observed. PCDD/Fs levels measured in the ambient air range from 0.058 to 0.127 pg-TEQ/m3. Higher PCDD/Fs levels in the ambient air were found during winter. In addition, PCDD/Fs levels measured in the soil range from 0.524 to 5.02 pg-TEQ/g d.m. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) did not provide sufficient evidence that the environmental PCDD/Fs contamination was caused by emissions from the Hsinchu MSWI. An unknown PCDD/Fs source was proposed using congener profile analysis and supported by both PCA and HCA.  相似文献   

13.
The available experimental information on the occurrence of PCDD/Fs in the Venice Lagoon, Italy, was compiled and used to calculate fugacities for the environmental compartments of sediment, suspended particulate matter (SPM), water and air and then used to estimate fugacity ratios and assess the likely net direction of flux between media. The bottom sediment: SPM fugacity ratios for different PCDD/Fs indicate conditions close to equilibrium, suggestive of the close coupling of SPM with re-suspended sediment. Sediment/water and the sediment/air fugacity ratios suggest that net flux directions vary depending on the congener and the location within the lagoon. Net sediment-water-air movement (i.e. re-mobilisation/volatilisation) is suggested for the lighter congeners from the industrial canals, where the highest PCDD/F concentrations in the lagoon occur. The tendency to volatilise increases with decreasing congener molecular weight. In contrast, net deposition (air-water-sediment) appears to be occurring for the heaviest (hepta- and octa-) substituted PCDD/Fs. OCDF represents a marker of the industrial district of the lagoon, decreasing in concentration and as a fraction of total PCDD/Fs with increasing distance. The fugacity-based quantitative water air sediment interaction (QWASI) mass-balance model was applied to the central part of the lagoon. The key parameters for the determination of the model output, identified by a sensitivity analysis, were: the sediment active depth, the sediment re-suspension and deposition rates, and the total input of PCDD/Fs to the system. The QWASI model also indicates the tendency for the lighter PCDD/Fs to be released from surface sediment to the water column.  相似文献   

14.
Particle-bound polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) were monitored at two sites in northern Greece for an eight-month period in 1999. PCDD/F concentrations were close to the lower end of reported values worldwide. Excepting a few cases, the PCDD/Fs homologue profile was stable. The gaseous PCDD/F fractions calculated were found to account for a small percentage of the total concentrations (<2% for OCDD/Fs and HpCDD/Fs, while 30-35% for TCDFs). Particle-bound PCBs were also found at low concentrations which, however, were higher at the urban site. Calculations of the dry deposition of particulate PCDD/ Fs and PCBs gave mean values of 0.52 and 0.59 pg I-TEQ/m2/day of PCDD/Fs, while 242 and 74 pg/m2/day of sigmaPCBs for the urban and the semirural areas respectively. An anticorrelation of PCDD/F concentrations with ambient temperature was derived particularly for the lower chlorinated congeners. A weak association with winds of western and southern origin was also observed. Factor analysis and literature source profiles were employed to identify possible emission sources. It was appeared that the PCDD/F compositional pattern of TSP is influenced by mixed sources the most prominent being uncontrolled fires and car exhausts.  相似文献   

15.
Lee CC  Chen HL  Su HJ  Guo YL  Liao PC 《Chemosphere》2005,59(10):1465-1474
The aim of this study was to evaluate the PCDD/Fs patterns in ambient air based on data information emitted from incinerator generated from ambient air measurements and those in serum. Four circular zones, namely A, B, C, and D, were identified based on simulated ambient annual average PCDD/Fs concentrations, from a selected municipal waste incinerator. Sixteen ambient samples were taken from the 4 circular zones across 4-seasons. Eighty-nine volunteers were recruited according to the demographic distribution within each zone. PCDD/Fs profiles were documented both for air and serum samples collected. Comparing to the congener patterns from ambient air and serum samples, we found that OCDD, OCDF, 1,2,3,4,6,7,8-HpCDD, and 1,2,3,4,6,7,8-HpCDF were the predominant groups among 17 congeners from both the ambient air and serum sample. And, factor analysis showed the distribution patterns of PCDD/Fs from ambient air and serum samples are almost identical across different zones, except for congener patterns of serum samples from residents in zone C. In addition, the average PCDD/Fs level significantly reduced for about 10 folds than those of the other three seasons when the incinerator was shut down in one of sampling periods. We might conclude that ambient air exposure was the most important contributor to PCDD/Fs levels in ambient air but not the single in serum. Therefore, another or more powerful source, such as occupational exposure, dietary intake or the consumption of local food, should be further investigated at the same time.  相似文献   

16.
Atmospheric deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) was investigated at four locations, namely at Yuancun, Wushan, Haizhu and Changban in Guangzhou City, Guangdong Province. The annual deposition fluxes of tetra- to octa-CDD/Fs (total PCDD/Fs) were found to range from 170 to 3000 (mean 1500) pg m−2 day−1, and the fluxes of total 2, 3, 7, 8-substituted PCDD/F congeners ranged from 2.1 to 41 (mean 20) pg WHO-TEQ m−2 day−1 at Wushan. The average deposition fluxes of total 2, 3, 7, 8-substituted PCDD/F congeners in rainy season were found to be 37, 27 and 28 pg WHO-TEQ m−2 day−1 at Yuancun, Haizhu and Changban, respectively, and the PCDD/F deposition fluxes behaved obviously higher in rainy season than in dry season. Results from regression analysis showed that number of rainy days, the amount of wet precipitation, PCDD/F concentrations in particles and organic carbon content played important roles in the variation of PCDD/F deposition fluxes. Monthly average temperatures change little over the year. Therefore, it only played a minor role in monthly variation of PCDD/F deposition fluxes. Particle deposition fluxes were generally not considered as the factor that could cause the differences in PCDD/F deposition fluxes between rainy and dry season, but were found to be related with PCDD/F deposition fluxes in rainy season or dry season. It was found that the profiles of PCDD/F homologs or congeners in the samples were the same either spatially or temporally, indicating that the PCDD/F emission sources were similar to one another. The similarities in PCDD/F homolog patterns and the differences in deposition fluxes between samples collected from heavy-traffic roadside and nearby residence house roof indicated that vehicle exhaust might be an important source for PCDD/F in Guangzhou. PCDD/F concentrations and profiles of PCDD/F homologs in atmospheric deposition were compared with those in both total suspended particles in air and soils, and conclusions indicated that atmospheric deposition possibly tended to remove lower-chlorinated DD/Fs from air and was one of sources for PCDD/Fs in soils.  相似文献   

17.
In 2005 and 2006, the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs) and metals (As, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sn, Tl and V) were measured in air samples collected in an industrial area of Sant Adrià del Besòs (Barcelona, Catalonia, Spain) where a municipal solid waste incinerator (MSWI) is placed, and in a background/control area. In general terms, concentrations of all environmental pollutants were higher at the industrial site. No significant seasonal/temporal variations were observed in any of the areas. No Pearson correlation was found between the PCDD/F concentrations and the environmental conditions of the two sampling periods considered. Principal component analyses (PCA) were performed to get information on the relationship among samples, pollutants, and emission sources. The results indicate that the MSWI of S. Adrià de Besòs is not a significant emission source of the above compounds for the area under its direct influence. Moreover, a notable difference in the PCDD/F congener profiles was found between ambient air and stack gas emissions, indicating that the current levels of PCDD/Fs are more related to other potential emissions sources rather than to those from the MSWI.  相似文献   

18.
Chang MB  Chi KH  Chang SH  Yeh JW 《Chemosphere》2007,66(6):1114-1122
Partitioning of PCDD/F congeners between vapor/solid phases and removal and destruction efficiencies achieved with selective catalytic reduction (SCR) system for PCDD/Fs at an existing municipal waste incinerator (MWI) and metal smelting plant (MSP) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP, operating temperature: 230 degrees C), wet scrubbers (WS, operating temperature: 70 degrees C) and SCR (operating temperature: 220 degrees C) as major air pollution control devices (APCDs). PCDD/F concentration measured at stack gas of the MWI investigated is 0.728 ng-TEQ/Nm(3). The removal efficiency of WS+SCR system for PCDD/Fs reaches 93% in the MWI investigated. The MSP investigated is equipped with EP (operating temperature: 240 degrees C) and SCR (operating temperature: 290 degrees C) as APCDs. The flue gas sampling results also indicate that PCDD/F concentration treated with SCR is 1.35 ng-TEQ/Nm(3). The SCR system adopted in MSP can remove 52.3% PCDD/Fs from flue gases (SCR operating temperature: 290 degrees C, Gas flow rate: 660 kN m(3)/h). In addition, the distributions of PCDD/F congeners observed in the flue gases of the MWI and MSP investigated are significantly different. This study also indicates that the PCDD/F congeners measured in the flue gases of those two facilities are mostly distributed in vapor phase prior to the SCR system and shift to solid phase (vapor-phase PCDD/Fs are effectively decomposed) after being treated with catalyst. Besides, the results also indicate that with SCR highly chlorinated PCDD/F congeners can be transformed to lowly chlorinated PCDD/F congeners probably by dechlorination, while the removal efficiencies of vapor-phase PCDD/Fs increase with increasing chlorination.  相似文献   

19.
Fly ash from municipal solid waste incinerators (MSWIs) has been characterized in terms of polychlorinated dibenzyl-p-dioxin and polychlorinated dibenzofuran (PCDD/F) content. Increasing values of PCDD/Fs have been found to correlate with decreasing temperatures of sampling points in flue gas treatment lines of the plants, confirming other researchers' findings about temperature as the major controlling parameter for the PCDD/F formation. Measured PCDD/F ratios show that de novo synthesis is the dominant formation mechanism. The increasing trends of particulate-bound PCDD/Fs can be explained not only through the dominant de novo synthesis process but also considering the adsorption of gaseous PCDD/Fs on fly ash deposits, even outside the typical de novo synthesis temperature ranges. The effective role of a post-combustor unit, imposed by Italian law to destroy PCDD/ Fs, also needs to be carefully reconsidered.  相似文献   

20.
Background, aim, and scope  The primary aim of this study was to explore the variations in PCDD/F levels and homologue profiles of Baltic surface sediments by comprehensively analyzing polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in samples from a large number of sites, encompassing not only previously known hotspot areas, but also sites near other potential PCDD/F sources, in pristine reference areas (in which there was no industrial activity) and offshore sites. Materials and methods  Surface sediment samples (146 in total) were collected at various points along the Swedish coast and offshore areas. In addition, bulk deposition was sampled, monthly, at a single site in northern Sweden during 1 year. The concentrations of tetra- through octa-substituted CDD/Fs were determined in both matrices. Results  Highly elevated concentrations of PCDD/Fs were found at many sites in coastal areas and concentrations were also slightly elevated in some offshore areas. Homologue profiles varied substantially amongst samples from coastal sites, while those from offshore and other pristine sediments were relatively similar. The offshore sediments showed different profiles from those observed in the deposition samples. Sediment levels of PCDD/Fs were not generally significantly correlated to organic carbon levels, except in some pristine areas. Comparison of data obtained in this and previous studies suggest that both their levels and profiles are similar today to those observed 20 years ago in coastal and offshore areas. The only detected trend is that their levels appear to have decreased slightly in the offshore area of the Bothnian Sea. Discussion  The localization of hotspot areas along the coast, the lack of consensus between PCDD/F profiles of sediments and general background, and their weak correlations with organic carbon suggest that PCDD/Fs in the study area largely originate from local/regional emissions. However, due to complicating factors such as sediment dynamics and land upheaval, it is not possible to conclude whether these pollutants derive from recent emissions or from a combination of recent emissions and re-distribution of previous inputs. Conclusions  The results show that: elevated levels of PCDD/Fs are present in both coastal and offshore areas of the Baltic Sea, the major hotspots are close to the shore, and there are large variations in profiles, indicating that local emissions are (or have been) the major causes of pollution. Recommendations and perspectives  In order to identify other hotspot areas and trace sources, comprehensive analysis of PCDD/Fs in surface sediments is needed in all areas of the Baltic Sea that have not been previously investigated. The high levels of PCDD/Fs observed in surface sediments also indicate a need to elucidate whether they are due mainly to current emissions or a combination of recent pollution and re-distribution of historically deposited pollutants. To do so, better understanding of sediment dynamics and present-day inputs, such as riverine inputs, industrial effluents, and leakage from contaminated soil is required. There are indications that contaminated sediments have a regional impact on fish contamination levels. However, as yet there is no statistically robust evidence linking contaminated sediments with elevated levels in Baltic biota. It should also be noted that the Baltic Sea is being massively invaded by the deep-burrowing polychaete Marenzielleria ssp., whose presence in sediments has been shown to increase water concentrations of hydrophobic pollutants. In awareness of this, it is clear that high levels in sediments cannot be ignored in risk assessments. In order to investigate the emission trends more thoroughly, analysis of PCDD/Fs in offshore sediment cores throughout the Baltic Sea is also recommended. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号