首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work, spectrophotometer was used as a detector for the determination of uranium from water, biological, and ore samples with a flow injection system coupled with solid phase extraction. In order to promote the online preconcentration of uranium, a minicolumn packed with XAD-4 resin impregnated with nalidixic acid was utilized. The system operation was based on U(VI) ion retention at pH 6 in the minicolumn at flow rate of 15.2 mL min?1. The uranium complex was removed from the resin by 0.1 mol dm?3 HCl at flow rate of 3.2 mL min?1 and was mixed with arsenazo III solution (0.05 % solution in 0.1 mol dm?3 HCl, 3.2 mL min?1) and driven to flow through cell of spectrophotometer where its absorbance was measured at 651 nm. The influence of chemical (pH and HCl (as eluent and reagent medium) concentration) and flow (sample and eluent flow rate and preconcentration time) parameters that could affect the performance of the system as well as the possible interferents was investigated. At the optimum conditions for 60 s preconcentration time (15.2 mL of sample volume), the method presented a detection limit of 1.1 μg L?1, a relative standard deviation (RSD) of 0.8 % at 100 μg L?1, enrichment factor of 30, and a sample throughput of 42 h?1, whereas for 300 s of the preconcentration time (76 mL of sample volume), a detection limit of 0.22 μg L?1, a RSD of 1.32 % at 10 μg L?1, enrichment factor of 150, and a sampling frequency of 11 h?1 were reported.  相似文献   

2.
The present study reports on the application of modified groundnut shell as a new, easily prepared, and stable sorbent for the extraction of trace amount of Cr(III) in aqueous solution. 2-Hydroxybenzaldiminoglycine was immobilized on groundnut shells in alkaline medium and then used as a solid phase for the column preconcentration of Cr(III). The elution was carried out with 3 mL of 2 mol?L?1 HCl. The amount of eluted Cr(III) was determined by spectrophotometry using cefaclor as a complexing reagent and by flame atomic absorption spectrometry (FAAS). Different experimental variables such as pH, amount of solid sorbent, volume and concentration of eluent, sample and eluent flow rate, and interference of other metal ions on the retention of Cr(III) were studied. Under the optimized conditions, the calibration curves were found to be linear over the concentration range of 13–104 and 10–75 μg?L?1 with a detection limit of 3.64 and 1.24 μg?L?1 for spectrophotometric method and FAAS, respectively. An enrichment factor of 200 and RSD of ±1.19–1.49 % for five successive determinations of 25 μg?L?1 were achieved. The column preconcentration was successfully applied to the analysis of tap water and underground water samples.  相似文献   

3.
The present research reports on the application of modified multiwalled carbon nanotubes as a new, easily prepared, and stable solid sorbent for the column preconcentration of ultra-trace amounts of cadmium in aqueous solution. Multiwalled carbon nanotubes were oxidized with concentrated HNO3 and modified with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol and then were used as a solid phase for the column preconcentration of Cd(II). Elution was carried out with 0.5 mol?L?1 HNO3. The amount of eluted Cd(II) was measured using electrothermal atomic absorption spectrometry. Various parameters such as pH, sample and eluent flow rate, eluent concentration, breakthrough volume, and interference of a great number of anions and cations on the retention of analyte on sorbent were studied. Under the optimized conditions, the calibration graph was linear in the range of 0.67 ng?L?1 to 5.0 μg?L?1 and the detection limit (3Sb, n?=?7) was 0.14 ng?L?1 in initial solution. A preconcentration factor of 300 and relative standard deviations of ±3.6 % for seven successive determinations of 3 ng of Cd(II) were achieved. The column preconcentration was successfully applied to the analysis of river water, waste water, and Persian Gulf water sample.  相似文献   

4.
In the present study, a separation/preconcentration procedure for determination of aluminum in water samples has been developed by using a new atomic absorption spectrometer concept with a high-intensity xenon short-arc lamp as continuum radiation source, a high-resolution double-echelle monochromator, and a charge-coupled device array detector. Sample solution pH, sample volume, flow rate of sample solution, volume, and concentration of eluent for solid-phase extraction of Al chelates with 4-[(dicyanomethyl)diazenyl] benzoic acid on polymeric resin (Duolite XAD-761) have been investigated. The adsorbed aluminum on resin was eluted with 5 mL of 2 mol L-1 HNO3 and its concentration was determined by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Under the optimal conditions, limit of detection obtained with HR-CS FAAS and Line Source FAAS (LS-FAAS) were 0.49 μg L?1 and 3.91 μg L?1, respectively. The accuracy of the procedure was confirmed by analyzing certified materials (NIST SRM 1643e, Trace elements in water) and spiked real samples. The developed procedure was successfully applied to water samples.  相似文献   

5.
The developed method is based on cold-induced aggregation microextraction of Se(IV) using the 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid as an extractant followed by spectrophotometry determination. The extraction of Se(IV) was performed in the presence of dithizone as the complexing agent. In this method, a very small amount of 1-butyl-3-methylimidazolium hexafluorophosphate was added to the sample solution containing Se-dithizone complex. Then, the solution was kept in a thermostated bath at 50 °C for 4 min. Subsequently, the solution was cooled in an ice bath and a cloudy solution was formed. After centrifuging, the extractant phase was analyzed using a spectrophotometric detection method. Some important parameters that might affect the extraction efficiency were optimized (HCl, 0.6 mol L?1; dithizone, 4.0?×?10?6 mol L?1; ionic liquid, 100 μL). Under the optimum conditions, good linear relationship, sensitivity, and reproducibility were obtained. The limit of detection (LOD) (3Sb/m) was 1.5 μg L?1, and the relative standard deviation (RSD) was 1.2 % for 30 μg L?1 of Se(IV). The linear range was obtained in the range of 5–60 μg L?1. It was satisfactory to analyze rice and various water samples.  相似文献   

6.
A novel improved preconcentration method known as rapidly synergistic cloud point extraction (RS-CPE) was established for nickel preconcentration and determination prior to its determination by flame atomic absorption spectrometry. In this work, the traditional CPE pattern was changed and greatly simplified in order to be applicable in metal extraction and detection. This method was accomplished in room temperature in 1 min. Non-ionic surfactant Triton X-114 was used as extractant. Octanol worked as cloud point revulsant and synergic reagent. The various parameters affecting the extraction and preconcentration of nickel such as sample pH, 2,2′-Furildioxime concentration, amounts of octanol, amounts of Triton X-114, type of diluting solvent, extraction time, and ionic strength were investigated and optimized. Under optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 2–200 μg L?1, and the limit of detection was 0.6 μg L?1 for nickel. The developed method was successfully applied for the determination of nickel in food and water samples. The results showed that, the proposed method can be used as a cheap, rapid, and efficient method for the extraction and preconcentration of nickel from real samples.  相似文献   

7.
A simple, rapid, and efficient sample pretreatment technique, based on solvent-based de-emulsification dispersive liquid–liquid microextraction (SD-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for simultaneous preconcentration and trace detection of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in water and urine samples. Some parameters such as acidity of solution, the amount of salt, type, and volume of extraction solvents, type of disperser/de-emulsifier solvent, and its volume were investigated and optimized. Under optimum extraction conditions, the limits of detections (LODs) of this method for MCPA and 2,4-D were 0.2 and 0.6 μg L?1 (based on 3Sb/m) in water and 0.4 and 1.6 μg L?1 in urine, respectively. Furthermore, dynamic linear range of this method for MCPA and 2,4-D was 1–300 and 2–400 μg L?1, repectively. Finally, the applicability of the proposed method was evaluated by extraction and determination of the herbicides in urine and different water samples.  相似文献   

8.
A simple, rapid, and efficient dispersive liquid–liquid microextraction method, followed by UV–Vis spectrophotometry was developed for the preconcentration and determination of Pd ions in water samples. Pd ions react with α-furildioxime (chelating agent) to form a hydrophobic complex. Various parameters were altered to study and optimize their effects on the extraction efficiency, such as pH, ligand concentration, the type and volume of extraction and dispersive solvents, extraction time, and salt concentration. Under optimized conditions, the method exhibited an enrichment factor (C org/C aq) of 25 and recovery more than 98 % within a very short extraction time. The linearity of the method ranged from 10 to 200 μg?L?1. The limit of detection was 1.1 μg?L?1. The relative standard deviation for the concentration of 100 μg?L?1 of Pd was 2.3 % (n?=?10). Finally, the developed method was successfully applied to the extraction and determination of Pd in tap, river, mineral, and sea water samples.  相似文献   

9.
An analytical method for the determination of diflufenican, mepanipyrim, pretilachlor, and fipronil in water samples was developed using single drop microextraction in the direct immersion mode and gas chromatography–mass spectrometry. A factorial fractionated design of type 26–1 at two levels was performed, to study the influence of experimental variables such as ionic strength, pH, agitation speed, extraction time, drop volume, and sample volume. To establish the optimal conditions for the variables that were significant, a Doehlert design was performed. The optimum conditions of extraction were 1 μL of heptane immersed in 4.0 mL of sample with continuous agitation at 500 rpm for 30 min at room temperature. The developed method proved to have good linearity for the range studied. The detection limits were 0.07 μg L?1 for diflufenican, 0.03 μg L?1 for mepanipyrim, 0.08 μg L?1 for pretilachlor, and 1.39 μg L?1 for fipronil. The method was validated on river water samples, showing the absence of matrix effect and recoveries ranged from 90.1 to 107.8 %. The results show that the method developed is accurate, sensitive, rapid, simple, and low cost, so it is recommended for application in the analysis of these different classes of pesticides in water samples.  相似文献   

10.
Constructing various green wetland examples for mangrove wetland systems is a useful way to use natural power to remediate the polluted wetlands at intertidal zones. Metallothioneins (MT) are involved in heavy metal tolerance, homeostasis, and detoxification of intracellular metal ions in plants. In order to understand the mechanism of heavy metal uptake in Aegiceras corniculatum, we isolated its metallothionein gene and studied the MT gene expression in response to heavy metals contamination. Here, we report the isolation and characterization of MT2 genes from young stem tissues of A. corniculatum growing in the cadmium (Cd) and lead (Pb) polluted wetlands of Quanzhou Bay, southeast of China. The obtained cDNA sequence of MT is 512 bp in length, and it has an open reading frame encoding 79 amino acid residues with a molecular weight of 7.92 kDa and the theoretical isoelectric point of 4.55. The amino acids include 14 cysteine residues and 14 glycine residues. It is a non-transmembrane hydrophilic protein. Sequence and homology analysis showed the MT protein sequence shared more than 60 % homology with other plant type 2 MT-like protein genes. The results suggested that the expression level of MT gene of A. corniculatum young stems induced by a certain range concentration of Cd2+ and Pb2+ stresses (0.2 mmol L?1 Pb2+, 1 mmol L?1 Pb2+, 0.2 mmol L?1 Pb2+, and 40 μmmol L?1 Cd2+; 1 mmol L?1 Pb2+ and 40 μmol L?1 Cd2+) compared with control might show an adaptive protection. The expression levels of MT gene at 20 h stress treatment were higher than those at 480 h stress treatment. The expression levels of MT gene with 0.2 mmol L?1 Pb2+ stress treatment were higher than those with 0.2 mmol L?1 Pb2+ and 40 μmol L?1 Cd2+ stress treatment, and the MT gene expression levels with 1 mmol L?1 Pb2+ treatment were higher than those with 1 mmol L?1 Pb2+ and 40 μmol L?1 Cd2+ treatment. There exists an antagonistic action between Pb2+ and Cd2+ in the MT metabolization of A. corniculatum.  相似文献   

11.
A simple and sensitive solid phase extraction (SPE) method on multiwalled carbon nanotubes (MWCNTs) is presented for the determination of cadmium, lead, nickel, copper, and zinc at trace levels combined with flame atomic absorption spectrometry. The effects of parameters like pH, sample volume, sample and eluent flow rates, eluent concentration, and volume and type of eluent on the recovery of trace elements was examined. The metals retained on the nanotube at pH 6.5 as α-benzoin oxime complexes were eluted by 10 mL 2 M HNO3 in acetone. The influence of matrix ions on the developed method was also evaluated. The preconcentration factor of the method was found to be 50. The detection limits for Cd(II), Pb(II), Ni(II), Cu(II), and Zn(II) were found as 1.7, 5.5, 6.0, 2.3, and 2.4 μg L?1, respectively. To test the accuracy of the method, the method was applied to TMDA-70 fortified lake water and Spinach 1570A standard reference materials. Addition recovery studies were applied to tap water and cracked wheat samples, and determination of the analyte elements was carried out in some food samples with good results.  相似文献   

12.
Nascent Amberlite XAD-4 has been used as the polymeric support for the synthesis of a stable extractor of metal ions, by incorporating phthalic acid through azo bridging. Elemental analyses and infra-red spectral and thermal studies were carried out for its characterization. The water regain value and hydrogen ion capacity were found to be 12.50 and 5.75 mmol g?1, respectively. The optimum pH range for the maximum sorption of Ni(II), Mn(II), Cu(II), Zn(II), Cd(II), Cr(III), and Co(II) was observed at pH 5.5–8.0 with the corresponding half-loading time (t 1/2) of 9, 5, 9, 9, 3, 9, and 5 min, respectively. The preconcentration factor for Ni(II), Mn(II), Cu(II), Zn(II), Cd(II), Cr(III), and Co(II) are 190, 190, 190, 180, 180, 160, and 160, with the corresponding limit of preconcentration in the range of 5.25–6.25 μg L?1. The detection limits, for flame atomic absorption spectrophotometry, were found to be 0.62, 0.60, 0.65, 0.75, 0.72, 0.84, and 0.85 μg L?1, respectively. Method has been successfully applied to the analysis of water samples, multivitamin formulations, infant food substitutes, hydrogenated oil, and fishes.  相似文献   

13.
We are introducing graphene oxide modified with amine groups as a new solid phase for extraction of heavy metal ions including cadmium(II), copper(II), nickel(II), zinc(II), and lead(II). Effects of pH value, flow rates, type, concentration, and volume of the eluent, breakthrough volume, and the effect of potentially interfering ions were studied. Under optimized conditions, the extraction efficiency is >97 %, the limit of detections are 0.03, 0.05, 0.2, 0.1, and 1 μg L?1 for the ions of cadmium, copper, nickel, zinc, and lead, respectively, and the adsorption capacities for these ions are 178, 142, 110, 125, and 210 mg g?1. The amino-functionalized graphene oxide was characterized by thermogravimetric analysis, transmission electron microscopy, scanning electron microscopy, and Fourier transform infrared spectrometry. The proposed method was successfully applied in the analysis of environmental water and food samples. Good spiked recoveries over the range of 95.8–100.0 % were obtained. This work not only proposes a useful method for sample preconcentration but also reveals the great potential of modified graphene as an excellent sorbent material in analytical processes.  相似文献   

14.
Amberlite XAD-4 resin functionalized with β-nitroso-α-naphthol was applied to an online system for the preconcentration and determination of uranium. U (VI) ions were retained on the minicolumn at an appropriate pH and then desorbed with acid solution. The amount of uranium in the eluate was measured spectrophotometrically at 650 nm using Arsenazo III as a colorimetric reagent. The limit of detection and the preconcentration factor were 1.8 μg L???1 and 10, respectively. The chemical and flow variables affecting the preconcentration were studied. The influence of several ions on the system was also investigated. The method was successfully applied for the evaluation of uranium in water and in effluent samples.  相似文献   

15.
In the present work, a batch preconcentration technique using nanoclay with 5-(4-dimethylaminobenzylidene)rhodanine coupled with electrothermal atomic absorption spectrometry was developed for the separation and determination of trace amounts of palladium. In this method, the sample solution was stirred with nanoclay as an adsorbent. Then, adsorbed palladium was subsequently eluted with HCl in acetone (1.5 mol L?1) and, finally, this eluate was injected to electrothermal atomic absorption spectrometry. Under the optimum conditions, the limit of detection and linear dynamic range were found to be 2.6 and 10.0–133 ng L?1 (in original solution), respectively. Furthermore, the enrichment factor and relative standard deviation of seven replicate determinations were 148 and ±5.1 %, respectively. This suggested method is simple, selective and sensitive and can be applied to the extraction and determination of palladium in water, tea leaves, synthetic sample and certified reference material with satisfactory results.  相似文献   

16.
This work proposes a procedure for the determination of total selenium content in shellfish after digestion of samples in block using cold finger system and detection using atomic fluorescent spectrometry coupled hydride generation (HG AFS). The optimal conditions for HG such as effect and volume of prereduction KBr 10 % (m/v) (1.0 and 2.0 ml) and concentration of hydrochloric acid (3.0 and 6.0 mol L?1) were evaluated. The best results were obtained using 3 mL of HCl (6 mol L?1) and 1 mL of KBr 10 % (m/v), followed by 30 min of prereduction for the volume of 1 mL of the digested sample. The precision and accuracy were assessed by the analysis of the Certified Reference Material NIST 1566b. Under the optimized conditions, the detection and quantification limits were 6.06 and 21.21 μg kg?1, respectively. The developed method was applied to samples of shellfish (oysters, clams, and mussels) collected at Todos os Santos Bay, Bahia, Brazil. Selenium concentrations ranged from 0.23?±?0.02 to 3.70?±?0.27 mg kg?1 for Mytella guyanensis and Anomalocardia brasiliana, respectively. The developed method proved to be accurate, precise, cheap, fast, and could be used for monitoring Se in shellfish samples.  相似文献   

17.
The paper presents the first report on the application of a lead film electrode for the determination of ultratrace concentrations of platinum. The procedure is based on preconcentration of the Pt(IV)-formaldehyde complexes at an in situ plated lead film electrode held at ?0.9 V (vs. Ag/AgCl), followed by a negatively sweeping differential pulse voltammetric scan. The composition of the supporting electrolyte, the influence of accumulation potential and time on the sensitivity of platinum responses are discussed. The detection limit of Pt(IV) with the accumulation time of 60 was equal to 9.2?×?10?12 mol L?1. The application of this method was tested by recovery of Pt(IV) from spiked environmental water samples.  相似文献   

18.
In this study, an ultra-sensitive and highly selective, rapid flow-injection spectrophotometric method for the determination of iron (II) and total iron has been proposed. The method was based on the reaction between iron (II) and 2′, 3, 4′, 5, 7-pentahydroxyflavone in slightly acidic solution with a strong absorption at 415 nm. The carrier solution used was 1?×?10?5 M 2′, 3, 4′, 5, 7-pentahydroxyflavone in 0.1 M HAc/Ac? buffer solution at pH 4.5. Parameters that affect simultaneously the determination of iron (II) and interfering ions were tested. The relative standard deviation for the determination of 50 μg L?1 iron (II) was 0.85 % (n?=?10), and the limit of detection (blank signal plus three times the standard deviation of the blank) was 3 μg L?1, both based on injection volumes of 20 μL. The method has been successfully applied to the determination of iron (II) and total iron in water samples and ore samples. The method was verified by analysing a certified reference material Zn/Al/Cu 43XZ3F.  相似文献   

19.
Arsenic is a widespread contaminant in the environment. The intake of water containing high concentrations of arsenic could have serious impact on human health, such as skin and lung cancer. In the European Union, thus, also in Italy, the arsenic limit in drinking water is 10 μg L?1. Several water remediation treatment technologies are available for arsenic removal. For some processes, the removal efficiencies can be improved after an oxidation step. Most full-scale applications are based on conventional oxidation processes for chemical micropollutant removal. However, if water contains arsenic and refractory organic contaminants, the advanced oxidation processes could be considered. The aim of this work was to investigate the effectiveness of ultraviolet (UV) radiation alone and in combination with hydrogen peroxide for the oxidation of arsenic and terbuthylazine (TBA). The experimental tests were performed in groundwater at the laboratory scale (0.1 mg L?1 As(III) and 10 μg L?1 TBA). Hydrogen peroxide alone (15 mg L?1) was ineffective on both arsenic and TBA oxidation; the 253.7-nm radiation alone did not oxidize arsenic(III), but photolyzed efficiently TBA (52 % removal yield at a UV dose of 1,200 mJ cm?2). The UV/H2O2 advanced oxidation (UV dose 600–2,000 mJ cm?2, 5–15 mg L?1 H2O2) was the most effective process for the oxidation of both arsenic and TBA, with observed oxidation efficiencies of 85 and 94 %, respectively, with 5 mg L?1 H2O2 and a UV dose of 2,000 mJ cm?2.  相似文献   

20.
This study reports the feasibility of applying directly suspended liquid-phase microextraction (DSLPME)-gas chromatography detection for the pre-concentration and determination of low levels of eight polychlorinated biphenyls (PCBs) in aqueous samples. The technique requires minimal sample preparation, analysis time and solvent consumption and represents significant advantages over conventional analytical methods. The experimental parameters such as salt content, sample temperature, stirring rate, extraction time, micro-drop volume and breakthrough volume were investigated and found to have significant influences on DSLPME. Under the optimal experimental conditions, the enrichment factor ranged from 578 to 729, and the recovery was above 93 %. Calibration curves possessed good linearity (R 2?>?0.99) over a wide concentration range of 0.1–10.0 μg L?1 with limits of detection ranging from 0.01 to 0.07 μg L?1. The relative standard deviations for 1.0 μg L?1 of PCBs in water by using internal standard were in the range 2–14 % (n?=?3). The proposed simple, accurate and sensitive analytical method was applied successfully to the determination of trace amounts of PCBs in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号