首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The mass, ionic and elemental size distributions of particulate matter (PM) measured indoors and outdoors in an apartment situated in a north–westward suburb of Prague are presented. The PM samples were collected by two Berner type low pressure impactors separating particles into 10 size fractions from 26 nm to 10 μm and were further analyzed by ion chromatography (IC) and proton induced X-ray emission (PIXE). Temperature, pressure and relative humidity were measured both indoors and outdoors parallel to PM sampling. The indoor and outdoor PM dynamics were recorded by two scanning mobility particle sizers (SMPS) and an aerodynamic particle sizer (APS). Finally, the ventilation rate was determined by a radon technique. Ion chromatography showed that the major inorganic components of the fine particle mode are sulfate, nitrate, and ammonium with very low indoor nitrate concentration. Crustal elements (Al, Si, Ca, Ti, Mn, and Fe) were associated with the coarse aerosol mode. The presence of people increased the mass concentration of coarse particles, whereas cooking, smoking, and burning of incense and candles contributed predominantly to the fine particle mode. Smoking and the burning of incense also increased the concentration of potassium, bromine and chlorine content in fine particles.  相似文献   

2.
Measurements of indoor and outdoor PM10, as well as indoor O3 and CO concentrations were conducted and are presented here. These measurements were carried out at an institute building, located in a suburban industrial area in Greece. Both indoor and outdoor PM10 samples were also collected and their elemental composition was identified by ED-XRF analysis. Twenty seven major, minor and trace elements were identified. The measurements took place generally in different periods of institute operation, from June 2004 to February 2005. The indoor PM10 concentrations which were measured during the normal operation period of the institute were found to be many times higher than the respective outdoor PM10 concentrations of the same periods. On the contrary, the indoor PM10 concentrations which were measured during the holiday period were found to be lower than their corresponding outdoor values. Indoor O3 and CO concentrations were found to be in low level. Indoor PM10 concentrations were found to be in a relative good correlation with O3 (r = 0.45) and in high correlation (r = 0.98) with CO concentrations. On average, total elements concentrations were much higher indoors relative to outdoors. Based on above findings we attempted to determine the pollution sources of the indoor environment and to investigate some parameters or chemical processes that affect indoor pollutants’ levels.  相似文献   

3.
The promotion of good indoor air quality in schools is of particular public concern for two main reasons: (1) school-age children spend at least 30% of their time inside classrooms and (2) indoor air quality in urban areas is substantially influenced by the outdoor pollutants, exposing tenants to potentially toxic substances. Two schools in Curitiba, Brazil, were selected to characterize the gaseous compounds indoor and outdoor of the classrooms. The concentrations of benzene, toluene, ethylbenzene, and the isomers xylenes (BTEX); NO2; SO2; O3; acetic acid (HAc); and formic acid (HFor) were assessed using passive diffusion tubes. BTEX were analyzed by gas chromatography–ion trap mass spectrometry and other collected gasses by ion chromatography. The concentration of NO2 varied between 9.5 and 23?µg m?3, whereas SO2 showed an interval from 0.1 to 4.8?µg m?3. Within the schools, BTEX concentrations were predominant. Formic and acetic acids inside the classrooms revealed intermediate concentrations of 1.5?µg m?3 and 1.2?µg m?3, respectively.  相似文献   

4.
Investigations at former dry cleaning sites in Denmark show that sewer systems often are a major vapor intrusion pathway for chlorinated solvents to indoor air. In more than 20 percent of the contaminated drycleaner sites in Central Denmark Region, sewer systems were determined to be a major vapor intrusion pathway. Sewer systems can be a major intrusion pathway if contaminated groundwater intrudes into the sewer and contamination is transported within the sewer pipe by water flow in either free phase or dissolved states. Additionally, the contamination can volatilize from the water phase or soil gas can intrude the sewer system directly. In the sewer, the gas phase can migrate in any direction by convective transport or diffusion. Indications of the sewer as a major intrusion pathway are:
  • higher concentrations in the upper floors in buildings,
  • higher concentrations in indoor air than expected from soil gas measurements,
  • higher concentrations in bathrooms/kitchen than in living rooms,
  • chlorinated solvents in the sewer system, and
  • a pressure gradient from the sewer system to indoor air.
Measurements to detect whether or not the sewer system is an intrusion pathway are simple. In Central Denmark Region, the concentrations of contaminants are routinely measured in the indoor air at all floors, the outdoor air, behind the water traps in the building, and in the manholes close to the building. The indoor and outdoor air concentration, as well as concentrations in manholes, are measured by passive sampling on sorbent samplers over a 14‐day period, and the measurements inside the sewer system are carried out by active sampling using carbon tubes (sorbent samplers). Furthermore, the pressure gradient over the building slab and between the indoor air and the sewer system are also measured. A simple test is depressurization of the sewer system. Using this technique, the pressure gradient between the sewer system and the indoor air is altered toward the sewer system—the contamination cannot enter the indoor air through the sewer system. If the sewer system is a major intrusion pathway, the effect of the test can be observed immediately in the indoor air. Remediation of a sewer transported contamination can be:
  • prevention of the contaminants from intruding into the sewer system or
  • prevention of the contaminated gas in the sewer system from intruding into the indoor air.
Remediation techniques include the following:
  • lining of the sewer piping to prevent the contamination from intruding into the sewer;
  • sealing the sewer system in the building to prevent the contamination from the sewer system to intrude the indoor air;
  • venting of manholes; and
  • depressurizing the sewer system.
  相似文献   

5.
Measurements of indoor and outdoor aerosol concentrations and their gaseous precursors (O3, NO and NO2) as well as volatile organic compounds (VOCs) concentrations were performed at two houses in the Oslo metropolitan area. The variability of the concentration of gaseous compounds was studied in respect to their sources in the indoor and outdoor environments. Domestic heating during the winter and photochemical production during the summer were the main sources for outdoor NOx and O3. In the indoor environment infiltration of outdoor air, candle burning, smoking and indoor chemical reactions were the main sources affecting their concentrations. The concentrations of VOCs outdoors were enhanced during the summer due to biogenic emissions whereas in the indoor environment their values were affected mostly by emissions from materials used during the recent refurbishing of the houses (>0.4 mg/m3).  相似文献   

6.
The effects of poor indoor air quality and mould growth in working environment are major problems in built environment, and there is a need to look for improvement of the health, comfort and productivity of the building occupants. Airborne mould sampling studies were conducted in a reference building located in Rockhampton, Central Queensland, Australia. Both indoor culturable and mould spore levels were observed. It was found through the indoor–outdoor ratios of the species that indoor concentrations are mostly related to the outdoor mould levels. The moulds differ in their relative humidity and temperature requirements to support surface growth. Indoor humidity has a significant effect on occupants comfort, perceived air quality, occupants’ health, building durability, emissions and energy efficiency. Practical hygrothermal simulation models are employed to analyse the combined heat and moisture behaviour within the built environment. A review of the current modelling options available to predict building performance based on energy and mass transport simulation is presented, and then a case study is presented with the assessment of indoor built environment to avoid mould problem.  相似文献   

7.
Tetrachloroethene (PCE) releases at a former dry cleaner resulted in impacts to soil and shallow groundwater beneath and adjacent to the building. Subsurface impacts led to vapor intrusion with PCE concentrations between 900 and 1,200 micrograms per cubic meter (μg/m3) in indoor air. The migration pathways of impacted soil vapor were evaluated through implementation of a helium tracer test and vapor sampling of an exterior concrete block wall. Results confirmed that the concrete block wall acted as a conduit for vapor intrusion into the building. A combination of remediation efforts focused on mass reduction in the source area as well as mitigation efforts to inhibit vapor migration into the building. Excavation of soils beneath the floor slab and installation of a spray‐applied vapor barrier resulted in PCE concentrations in indoor air decreasing by over 97.9 percent. Operation of an active ventilation system installed under the floor slab and groundwater remediation via injections of nano‐scale zero valent iron (nZVI) further reduced PCE concentrations in indoor air by over 99.8 percent compared to baseline conditions. While significant reductions of PCE concentrations in groundwater were observed within two months after injection, maximum reductions to PCE concentrations in indoor air were not observed for an additional 12 months. © 2014 Wiley Periodicals, Inc.  相似文献   

8.
When determining whether or not remediation of subslab contamination is warranted, it is often important to know if the presence of volatile organic compounds (VOCs) in indoor air is caused primarily by interior sources, or primarily by subslab contamination. With a Building Pressure Control test, the pressure differential across the building envelope and, thereby, also the pressure differential across the slab, can be controlled by a blower. By measuring the indoor air concentrations of VOCs under depressurization (upward pressure gradient over the slab) and under pressurization (downward pressure gradient over the slab), it can be determined if the subslab contamination contributes significantly to the VOC concentrations in indoor air. This technique has been applied at several sites in the Central Denmark Region, and the results show that a Building Pressure Control test is a quick and effective method to examine if VOC contamination in indoor air is caused primarily by interior sources or primarily by subslab sources. With numerous measurement points in the indoor air, at some sites this test method has identified the area where the subslab contamination is located. A pressure differential at ?5/+5 Pa across the building envelope was sufficient at all the test sites to control the pressure gradient across the slab to be uniquely upward/downward.  相似文献   

9.
In the developing world, the vast majority of people rely on solid biomass fuels for cooking and heating which results in poor indoor air quality. The present study determined indoor air quality in some rural and urban areas of Pakistan. Measurements were made of particulate mass (PM10, PM2.5 and PM1), number concentration and bioaerosols in different micro environments. PM10 concentrations of up to 8,555 μg/m3 were observed inside the kitchens where biofuels were used as energy source. Cleaning and smoking was identified as a major source of indoor particulate pollution and concentrations of more than more than 2,000 μg/m3 were recorded in the living room during these activities. Indoor number concentrations in Lahore were typically greater than those observed outdoors in European cites. At a rural site the highest Colony Forming Units (CFUs) were in the 0.5 μm–2 μm size fraction, while at the urban location CFUs were dominant for 2 μm–16 μm. It was observed that CFUs(Colony Forming Units) counts were higher inside living rooms than kitchens. It is important to note that women and children were exposed to extremely high levels of particulates during cooking. Overall, indoor air quality in Pakistan was poor and there is a dire need to take a serious step to combat with it.  相似文献   

10.
以宝鸡第二发电厂间接空冷机组为例,分别采用德国AUSTAL2000大气预测模式与美国AERMOD大气预测模式,对烟塔合一和烟囱两种排放方式的大气环境影响进行分析预测,并分析了地形因素对预测结果的影响。通过对比分析得知,烟塔合一排放的地面浓度分布较分散,而烟囱排放造成的地面浓度分布较集中。考虑地形影响时采用AUSTAL2000计算的烟塔合一地面浓度比AERMOD计算的烟囱小,不考虑地形时则反之。  相似文献   

11.
The amount of atmospheric pollutants emitted through the incineration of healthcare wastes can be estimated using emission factors. Emission factors have been published without including sufficient information about the types of wastes incinerated. This paper reports the first emission factors estimated for the incineration of wastes segregated into different types according to the Portuguese legislation. One controlled-air incinerator without air pollution control devices was used in the research. The main objectives of the study were: (i) to estimate the emission factors for particulate matter, dioxins, heavy metals and gaseous pollutants, according to the type of waste incinerated; (ii) to evaluate the quality of atmospheric emissions; and (iii) to define a methodology for the management of atmospheric emissions, evaluating the influence of type of waste incinerated and of the segregation method used on the emitted amounts. It was concluded that: (i) when emission factors are not associated with the type of incinerated mixture, the utility of the emission factors is highly doubtful; (ii) without appropriate equipment to control atmospheric pollution, incineration emissions exceed legal limits, neglecting the protection of human health (the legal limit for pollutant concentrations could only be met for NO(x), all other concentrations were higher than the maximum allowed: dioxins, 93-710 times; Hg, 1.3-226 times; CO, 11-24 times; SO(2), 2-5 times; and HCl, 9-200 times); (iii) rigorous segregation methodologies must be used to minimize atmospheric emissions, and incinerate only those wastes that should be incinerated according to the law. A rigorous segregation program can result in a reduction of the amount of waste that should be incinerated by 80%. A reduction in the quantity of waste incinerated results in a reduction on the amounts of pollutants emitted: particulate matter, 98%; dioxins, 99.5%; As, Cd, Cr, Mn and Ni, respectively, 90%, 92%, 84%, 77% and 92%; Hg and Pb, practically eliminated; SO(2) and NO(x), 93%; and CO and HCl, more than 99%.  相似文献   

12.
A health risk assessment of long-term emissions of carcinogenic and non-carcinogenic air pollutants has been carried out for the municipal solid waste incinerator (MSWI) of the city of Taranto, Italy. Ground level air concentrations and soil deposition of carcinogenic (Polychlorinated Dibenzo-p-Dioxins/Furans and Cd) and non-carcinogenic (Pb and Hg) pollutants have been estimated using a well documented atmospheric dispersion model. Health risk values for air inhalation, dermal contact, soil and food ingestion have been calculated based on a combination of these concentrations and a matrix of environmental exposure factors. Exposure of the surrounding population has been addressed for different release scenarios based on four pollutants, four exposure pathways and two receptor groups (children and adults). Spatial risk distribution and cancer excess cases projected from plant emissions have been compared with background mortality records. Estimated results based on the MSWI emissions show: (1) individual risks well below maximum acceptable levels, (2) very small incremental cancer risk compared with background level.  相似文献   

13.
Oil refining is among the industrial activities that emit considerable amounts of air pollutants into the atmosphere. Nitrogen oxides are important air pollutants that are emitted by oil refineries as products of combustion processes. The ambient air concentrations of nitrogen oxide (NO) and nitrogen dioxide (NO2) were monitored continuously at a site close to an oil refinery, near the city of Corinth in Greece, during autumn 1997 together with the main meteorological parameters. The contribution of the oil refinery to the measured atmospheric levels of nitrogen oxides was estimated. The ambient air concentration of nitrogen oxides in the area surrounding the oil refinery were generally lower than the ambient air concentrations in the urban area of Athens in Greece, and the NO2 levels were always below the existing air quality standards. The influence of the refinery emitted NOx in the photochemical production of ozone seems to be more important in terms of human and vegetation exposure given the high ozone backgrounds measured in the area.  相似文献   

14.
To assess the effect of changes in traffic density and fuels used for heating at the beginning of the 1990s, 1992–2005 monthly averages of PM10, SO2, NO2, NO, CO and O3 from Prague, the Czech capital, were analyzed together with long term trends in emissions of major pollutants, fuel consumption and number of vehicles registered in Prague. The data from all monitoring stations were retrieved from the database of the state automated monitoring system. Correlation coefficients between ambient monthly averaged temperature and all pollutants of concern showed distinct seasonal trends. The results showed that while SO2 and to some extent also CO concentrations dropped namely in the first half of the analyzed period (1992–1997) as a result decreased fossil fuel consumption for local heating, the behaviour of other pollutant concentrations followed a different pattern. PM10 concentrations decreased during the beginning of the 1990s but showed a sign of increase after 2000. Concentrations of ozone and NO2 did not reveal any significant change throughout the whole studied period. It can be concluded that during the studied period traditional urban sources of pollution, such as coal and oil combustion, lost their importance but were simultaneously substituted by pollutants from automotive transport (namely PM and NO2) making the problem of air quality even worse.  相似文献   

15.
Fugitive pollutant emissions from municipal solid waste landfills have the potential to cause annoyance and health impacts in the surrounding residential areas. The overall objective of this research was to perform an assessment of fugitive pollutant emissions and a dispersion analysis downwind of a specific landfill site. The study was performed at the closed Ano Liosia landfill site which is located in the greater Athens area. The human exposure from priority to health-risk pollutants emitted from landfill, such as vinyl chloride and benzene, was estimated by the landfill gas emission LandGEM 2.01 software combined with the atmospheric long-term dispersion model ISC3-LT. The emission and meteorological conditions under which the models were applied referred to the worst-case scenario. This scenario was used for the evaluation of the maximum human exposure assessed beyond the Ano Liosia landfill towards the residential areas. The above scenario provides the minimum downwind distance of the health-risk zone which is calculated to be equal to 1.5 km from the landfill. Within this distance the assessed air pollutant concentration for several air pollutants was significantly above the World Health Organization reference lifetime exposure health criteria. Finally, the applied methodology was used in the Ano Liosia landfill, where atmospheric concentrations of pollutants measured in the field were compared with model predictions.  相似文献   

16.
Data from an ozone episode (2–5 June, 1998) in the Milan metropolitan area were used for an application of two photochemical grid models: UAM-V and CALGRID. To assure a fair comparison, the models were run on the same domain and grid size, with same source emission inputs, CALMET diagnostic meteorology, and initial and boundary conditions taken from air quality data and literature values. Hourly emissions were derived from the AutoOil-II programme inventory except for on-road mobile source emissions; a new traffic emission inventory, based on both COPERT II methodology and road classification has been developed. NOx and O3 concentration results were compared to local network monitoring data. Results indicate that both models predict the highest ozone values along the north-east direction and are able to reproduce the ozone daytime trend though differences can be found between the two models on ozone spatial distribution. Average normalised bias for both models is about 50%, peak daily ozone concentrations are underestimated, with simulated peak shapes broader than the observed ones and a temporal shift between the two models. Night-time concentration levels of pollutants were not successfully reproduced due to an incorrect parameterisation of vertical turbulence calling for further work.  相似文献   

17.
The air quality in urban areas is on the one hand determined by the intensity of emissions. On the other hand atmospheric dispersion and chemical transformation conditions as well as topographic location have great influence on the ambient air concentrations. Within, this study the correlation between pollutant concentrations and the dynamics of atmospheric barrier and mixing layers has been experimentally investigated by tethered balloon soundings.The most important barrier layer is the surface inversion. During clear sky it develops in the late afternoon and is dissolved by warm air from the heated ground in the morning. Emitted pollutants are kept beneath this inversion. But, at the same time, the component ozone is depleted below and stored above the layer within the so called `ozone reservoir layer'. During night elevated mountain sites are decoupled from the ground conditions and stay within this reservoir without a remarkable nocturnal decrease of ozone concentration. The regularly observed ground level ozone increase in the morning hours is firstly caused by down mixing from the reservoir. The conditions and dynamics are illustratively depicted by vertical profiles of the different components and diagrams of temperature and concentration isopleths over the height and the experiment time lasting over five days.  相似文献   

18.
In the present study the horizontal distribution of columnar aerosol optical thicknessderived at high spatial resolution from Earth observation satellite data in the Lombardy area (Italy) was converted to the horizontal distribution of optically effective aerosols concentration at the ground level. This was achieved by incorporating information on atmosphere's mixing height, at which pollutants released at ground level are vertically dispersed by convection or mechanical turbulence. The resulted fields compared favourably to pollutant concentration measurements provided by the ground stations. These results show that it is possible to calculate mean concentration fields by using the spatial distribution of aerosol optical thickness (AOT) measured by satellite normalized by the atmospheric mixing height. The advantage of satellites in measuring AOT is that they can capture all actual emissions compared to the models, which are based on inventoried data.  相似文献   

19.
Municipal solid waste treatment facilities are generally faced with odorous nuisance problems. Characterizing and determining the odorous charge of indoor air through odour units (OU) is an advantageous approach to evaluate indoor air quality and discomfort. The assessment of the OU can be done through the determination of volatile organic compounds (VOCs) concentrations and the knowledge of their odour thresholds. The evaluation of the presented methodology was done in a mechanical–biological waste treatment plant with a processing capacity of 245.000 tons year?1 of municipal residues. The sampling was carried out in five indoor selected locations of the plant (Platform of Rotating Biostabilizers, Shipping warehouse, Composting tunnels, Digest centrifugals, and Humid pre-treatment) during the month of July 2011. VOC and volatile sulphur compounds (VSCs) were sampled using multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) and Tenax TA tubes, respectively, with SKC AirCheck 2000 pumps. The analysis was performed by automatic thermal desorption (ATD) coupled with a capillary gas chromatography (GC)/mass spectrometry detector (MSD). One hundred and thirty chemical compounds were determined qualitatively in all the studied points (mainly alkanes, aromatic hydrocarbons, alcohols, aldehydes, esters, and terpenes), from which 86 were quantified due to their odorous characteristics as well as their potentiality of having negative health effects. The application of the present methodology in a municipal solid waste treatment facility has proven to be useful in order to determine which type of VOC contribute substantially to the indoor air odorous charge, and thus it can be a helpful method to prevent the generation of these compounds during the treatment process, as well as to find a solution in order to suppress them.  相似文献   

20.
Soil gas vapor intrusion (VI) emerged in the 1990s as one of the most important problems in the investigation and cleanup of thousands of sites across the United States. A common practice for sites where VI has been determined to be a significant pathway is to implement interim building engineering controls to mitigate exposure of building occupants to VI while the source of contamination in underlying soil and groundwater is assessed and remediated. Engineering controls may include passive barriers, passive or active venting, subslab depressurization, building pressurization, and sealing the building envelope. Another recent trend is the emphasis on “green” building practices, which coincidentally incorporate some of these same engineering controls, as well as other measures such as increased ventilation and building commissioning for energy conservation and indoor air quality. These green building practices can also be used as components of VI solutions. This article evaluates the sustainability of engineering controls in solving VI problems, both in terms of long‐term effectiveness and “green” attributes. Long‐term effectiveness is inferred from extensive experience using similar engineering controls to mitigate intrusion of radon, moisture, mold, and methane into structures. Studies are needed to confirm that engineering controls to prevent VI can have similar long‐term effectiveness. This article demonstrates that using engineering controls to prevent VI is “green” in accelerating redevelopment of contaminated sites, improving indoor air quality, and minimizing material use, energy consumption, greenhouse gas emissions, and waste generation. It is anticipated that engineering controls can be used successfully as sustainable solutions to VI problems at some sites, such as those deemed technically impracticable to clean up, where remediation of underlying soil or groundwater contamination will not be completed in the foreseeable future. Furthermore, green buildings to be developed in areas of potential soil or groundwater contamination may be designed to incorporate engineering controls to prevent VI. © 2009 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号