首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 496 毫秒
1.
The simultaneous removal of organic and nitrogen and molecular weight distribution (MWD) of residual soluble chemical oxygen demand (RSCOD) in final effluent were investigated using entrapped mixed microbial cells (EMMC) and conventional activated sludge processes. Two different types of processes using EMMC carriers demonstrated better organic and nitrogen removal performance because of the high solids retention time (SRT) compared with the activated sludge process. Regarding the RSCOD, the longer SRT process (EMMC) was affected by reducing the hydraulic retention time, resulting in the increase of high-molecular-weight materials. On the other hand, reducing the aeration period had significantly affected the MWD in the shorter SRT process (activated sludge), resulting in an increase of low-molecular-weight materials.  相似文献   

2.
The activated sludge process is the most common method of secondary municipal wastewater treatment; solids retention time (SRT) is the key control parameter for this process. Typically, operating at long SRT is considered only for nitrification, but there are additional benefits of high SRT operation. This paper presents experimental and literature evidence to demonstrate three major additional benefits of long SRT operation: increased oxygen transfer efficiency; improved biomass particle size distribution, which results in more efficient clarification with fewer effluent particles and suspended solids; and enhanced removal of many emerging contaminants such as pharmaceuticals, personal care products, and endocrine disrupting compounds. This paper presents experimental results from several treatment plants that showed increasing oxygen transfer efficiency and particle size with increasing SRT, and evidence documenting improved removal of emerging contaminants and biodegradable organic carbon. A long-term survey of three treatment plants concludes that operating at higher SRT is not as energy intensive as typically assumed.  相似文献   

3.
Solids retention time (SRT), biological scum trapping and recycle, and the dynamic equilibrium between Nocardioform populations in the foam and the mixed liquor are the controlling factors in activated sludge foaming events caused by Nocardioform bacteria. For the operating modes described in this paper, a cured mixed liquor foaming condition (filament counts of approximately 10(5) intersections/g volatile suspended solids) was only achieved when SRT control, selective wasting, and polymer addition were in effect. Solids retention time control, with the SRT remaining below 1.5 days, and selective wasting will cure a severely foaming mixed liquor, but effects will only be observed after 3 or 4 months after implementation. The combined wastage of Nocardioform bacteria from selective wasting and SRT control can ensure long-term foam control to the operation of a pure-oxygen activated sludge system with foam-trapping features. An SRT of 0.3 days will result in the complete washout of Nocardioform bacteria from the activated sludge system, which can then operate at an SRT of 3 days free of Nocardioform. Polymer addition to mixed liquor is only effective for foam control when a large portion of the system biomass exists as a heavy layer of foam above the mixed liquor.  相似文献   

4.
Analytical technology is continuously improving, developing better methods for isolating and concentrating trace compounds in environmental samples. Polycyclic and nitro musks (PNMs) are one group of emerging trace compounds detected in municipal wastewater. Differences in sample storage, preparation, and extraction methods for their measurement have led to variability in results. We analyzed 11 PNMs by GC/MS and compared the results of different storage times and extraction methods (supercritical fluid (SFE) or microwave-assisted (MAE)) for 202 samples of primary sludge, waste activated sludge (WAS), raw sludge, and aerobically/anaerobically digested biosolids collected from Canadian municipal wastewater treatment plants. Sixty-three air-dried samples were extracted by SFE, and 139 air-dried, centrifuged, or filtered samples were extracted by MAE. The mean surrogate recoveries were 89% (standard deviation (SD)=11%) for d(10)-anthracene by SFE and 88% (SD=14%) for d(10)-phenanthrene by MAE. Storage study results showed that PNM concentrations changed by a mean of 7% and 9% for primary sludge and WAS respectively after four weeks and decreased up to 25% after 13.5 months of storage in amber glass containers at -18 degrees C. Air-drying of sludge at room temperature caused losses of about 50% of PNM concentrations compared to centrifugation. The proportions of PNMs present in the liquid phase of sludge samples were less than 5% compared to proportions in the sludge solids. The most complete liquid-solid separation was achieved by filtration of frozen/thawed sludge samples, producing a liquid phase that contained less than 1% of the total musk content of the sample.  相似文献   

5.
The removal of particulate material in the aeration basin of the activated sludge process is mainly attributed to bioflocculation and hydrolysis of particulate substrate. The bioflocculation process in the aeration tank of the activated sludge process occurs only under favorable conditions in the system, and several common operational parameters affect its performance. The principal objective of this research was to observe the effect of mixed liquor suspended solids, solids retention time (SRT), and extracellular polymer substances on the removal of particulate substrate by bioflocculation. A first-order particulate removal expression, based on flocculation, accurately described the removal rates for supernatant suspended solids and colloidal chemical oxygen demand. Based on the results presented in this investigation, a mixed liquor concentration of approximately 2200 mg/L, an SRT of at least 3 days, and a contact time of 30 minutes are needed for relatively complete removal of the particulate substrate in a plug-flow reactor.  相似文献   

6.
污泥龄对LSP & PNR污泥减量新工艺运行效能的影响   总被引:2,自引:1,他引:1  
通过研究分析污泥龄(SRT)对富磷污水除磷的LSP&PNR污泥减量新工艺运行效果的影响,结果发现,延长污泥龄有利于提高系统的厌氧释磷能力,但不影响其总的除磷率,同时磷的回收比例增大,当SRT=50 d时,磷回收率取得最大值70.4%;LSP&PNR系统污泥龄增加,还有利于污泥产率的降低。试验还发现,排富磷污水除磷的长污泥龄LSP&PNR系统的除磷效率与污泥产率之间不存在制约关系,即系统可以同时获得优异的污泥减量与生物除磷效果,当SRT=50 d时,每降解1 kg COD仅产生0.143 kg污泥,而除磷率达最高值928%;LSP&PNR系统中SRT、DO与SVI之间存在一定的相关性,在供氧充足(DO=0.8~1.5 mg/L)条件下,SRT增加,SVI越高,但对于SRT为50 d的LSP&PNR系统,稳定运行时没有污泥膨胀之虞。  相似文献   

7.
Chlorination is often used to control filamentous bulking in activated sludge systems. Pure culture and mixed-liquor experiments showed that soluble potassium (K+) concentrations increased by 2.4 mg/L (80%) and 1.5 to 3.6 mg/L (11 to 30%) in the bulk liquid phase of pure and activated sludge cultures that were exposed to chlorine, relative to unchlorinated controls. Effluent turbidity and total suspended solids from settled mixed liquor increased significantly in both short-term batch and sequencing batch reactor experiments when chlorine mass load increased above 6 milligrams of chlorine per gram mixed liquor volatile suspended solids (mg Cl2/g MLVSS) in a single dose, which correlated with a localized chlorine concentration at the dose point of 10 mg/L as Cl2 or greater. The results support the hypothesis that the glutathione-gated potassium efflux (GGKE) bacterial stress response may contribute to increased effluent turbidity associated with high doses of mixed-liquor chlorination. It is suggested that potassium is a useful parameter to monitor at full-scale facilities when determining chlorine mass doses that should be used to control filaments and minimize increases in effluent turbidity.  相似文献   

8.
This paper describes results from a pilot study of a novel wastewater treatment technology, which incorporates nutrient removal and solids separation to a single step. The pseudoliquified activated sludge process pilot system was tested on grit removal effluent at flowrates of 29.4 to 54.7 m3/d, three different solid residence times (SRT) (15, 37, and 57 days), and over a temperature range of 12 to 28 degrees C. Despite wide fluctuations in the influent characteristics, the system performed reliably and consistently with respect to organics and total suspended solids (TSS) removals, achieving biochemical oxygen demand (BOD) and TSS reductions of > 96% and approximately 90%, respectively, with BOD5 and TSS concentrations as low as 3 mg/L. Although the system achieved average effluent ammonia concentrations of 2.7 to 3.2 mg/L, nitrification efficiency appeared to be hampered at low temperatures (< 15 degrees C). The system achieved tertiary effluent quality with denitrification efficiencies of 90 and 91% total nitrogen removal efficiency at a total hydraulic retention time of 4.8 hours and an SRT of 12 to 17 days. With ferric chloride addition, effluent phosphorous concentrations of 0.5 to 0.8 mg/L were achieved. Furthermore, because of operation at high biomass concentrations and relatively long biological SRTs, sludge yields were over 50% below typical values for activated sludge plants. The process was modeled using activated sludge model No. 2, as a two-stage system comprised an aerobic activated sludge system followed by an anoxic system. Model predictions for soluble BOD, ammonia, nitrates, and orthophosphates agreed well with experimental data.  相似文献   

9.
There is increasing interest in the United States in producing biosolids from municipal wastewater treatment that meet the criteria for Class A designation established by the U.S. Environmental Protection Agency. Class A biosolids are intended to be free of pathogens and also must meet requirements for reduction of the vector-attraction potential associated with untreated sludge. High-temperature processes are considered to produce Class A biosolids if the combination of operating temperature and treatment time exceeds minimum criteria, but this option is not applicable to mixed, continuous-flow reactors. Such reactors, or any combination of reactors that does not meet the holding time requirement at a specific temperature, must be demonstrated to inactivate pathogens to levels consistent with the Class A criteria. This study was designed to evaluate pathogen inactivation by thermophilic anaerobic digestion in a mixed, continuous-flow reactor followed by batch or plug-flow treatment. In this first of a two-part series, we describe the performance of a continuous-flow laboratory reactor with respect to physical and chemical operating parameters; microbial inactivation in the combined continuous-flow and batch treatment system is described in the second part. Sludges from three different sources were treated at 53 degrees C, while sludge from one of the sources was also treated at 55 and 51 degrees C. Relatively short hydraulic retention times (four to six days) were used to represent a conservative operating condition with respect to pathogen inactivation. Treatment of a fermented primary sludge led to an average volatile-solids (VS) destruction efficiency of 45%, while VS destruction for the other two sources was near or below 38%, the Class A criterion for vector attraction reduction. Consistent with other studies on thermophilic anaerobic digestion of sludges at short residence times, effluent concentrations of volatile fatty acids (VFAs) were relatively high. Also consistent with other studies, the most abundant VFA in the effluent was propionate. Gas production ranged from 0.3 to 0.5 m3/kg VS fed and from 0.8 to 1.3 m3/kg VS destroyed.  相似文献   

10.
This study evaluated the use of steam explosion as a pretreatment for municipal wastewater treatment sludges and biosolids as a technique for enhancing biogas generation during anaerobic digestion. Samples of dewatered anaerobic digester effluent (biosolids) and a mixture of thickened waste activated sludge (TWAS) and biosolids were steam-exploded under differing levels of intensity in this study. The results indicate that steam explosion can solublize components of these sludge streams. Increasing the intensity of the steam-explosion pressure and temperature resulted in increased solublization. The steam-explosion pretreatment also increased the bioavailability of sludge components under anaerobic digestion conditions. Increasing the steam-explosion intensity increased the ultimate yield of methane during anaerobic digestion. Batch anaerobic digestion tests suggested that pretreatment at 300 psi was the most optimal condition for enhanced biogas generation while minimizing energy input. Semicontinuous anaerobic digestion revealed that the results that were observed in the batch tests were sustainable in prolonged operation. Semicontinuous digestion of the TWAS/biosolids mixture that was pretreated at 300 psi generated approximately 50% more biogas than the controls. Semicontinuous digestion of the pretreated biosolids resulted in a 3-fold increase in biogas compared with the controls. Based on capillary suction test results, steam-explosion pretreatment at 300 psi improved the dewaterability of the final digested sludge by 32 and 45% for the TWAS/ biosolids mixture and biosolids, respectively, compared with controls. The energy requirements of the nonoptimized steam-explosion process were substantially higher than the additional energy produced from enhanced digestion of the pretreated sludge. Substantial improvements in energy efficiency will be required to make the process viable from an energy perspective.  相似文献   

11.
进水水质成分改变引发的污泥粘性膨胀及控制   总被引:2,自引:0,他引:2  
在研究强化SBR工艺除污性能时,由于可溶性淀粉投加导致进水水质成分发生改变,污泥沉降性能在短时间内迅速恶化,污泥出现大量的粘液。镜检发现,大量指状菌胶团异常增殖且丝状菌的数量也逐渐减少。实验结果表明,系统膨胀属于污泥粘性膨胀。停止可溶性淀粉和提高主反应池的DO浓度,污泥粘性膨胀并未得到恢复,但污泥粘液逐渐消失。粘液消失后,通过模拟前期进水水质成分和缩短泥龄,污泥粘性膨胀得以控制,污泥沉降性能在短时间内恢复。实验还研究了污泥粘性膨胀对污染物去除性能的影响。  相似文献   

12.
The conventional anaerobic digestion process, requiring long solids retention times (SRTs) to digest solids, is currently viewed as impractical for the pulp and paper industry because of high capital costs associated with the construction of new digesters. Recent developments in sludge solubilization technology could be promising in reducing digester size, which also allows for the potential use of decommissioned tanks, both of which can reduce the capital cost. Three pretreatment technologies for use with anaerobic digestion were tested on laboratory-scale to investigate their feasibility. The SRTs in all three digesters systematically decreased from 20 to 3 days. The reference digester was fed waste activated sludge (WAS) to serve as the control at the same SRTs. The other digesters were fed WAS that had been preconditioned using mechanical shearing, sonication, or high-pressure homogenization technology. Anaerobic digestion with high-pressure homogenization produced as much methane at 3-day mean SRT as that from the reference digester operated at 20-day SRT. Therefore, a new digester can theoretically be 85% smaller than a conventional digester. An added benefit of WAS to methane conversion is the recovery of nutrients nitrogen and phosphorus.  相似文献   

13.
不同生物营养物处理工艺剩余污泥中温水解特性   总被引:1,自引:0,他引:1  
为了解不同生物营养物处理(BNR)工艺剩余污泥性质差异及其中温水解特性,采用序批式实验研究了来源于Orbal氧化沟(OD)和倒置A2/O工艺剩余污泥在中温水解过程中污泥浓度、营养物释放、污泥粒径、污泥絮凝性、污泥比阻及污泥胞外聚合物(EPS)的历时变化。结果表明,相同泥龄(约18 d)条件下,Orbal OD剩余污泥氮含量较高,倒置A2/O剩余污泥磷含量较高,两者VSS/SS均低于0.6,导致中温水解过程污泥减量空间有限、氮磷释放速率不同。此外,尽管倒置A2/O工艺剩余污泥絮体尺寸及絮凝能力明显大于Orbal OD工艺剩余污泥的对应值,但两污泥比阻相近。中温水解过程中,两污泥絮体的尺寸均变小、絮凝能力均降低、比阻均增高;两者的胞外聚合物均呈现增高再降低趋势,且蛋白质均占EPS质量的75%以上,为主要的胞外物质。  相似文献   

14.
Uniform lime incorporation into sewage sludge is critical for biosolid lime stabilization processes. There is no class B biosolids regulation for lime incorporation. The slurry method is currently used to evaluate the pH of limed biosolids, but this method homogenizes the biosolids and potentially masks poor lime mixing. In this study, a flat-surface pH electrode was used in bench-scale and full-scale experiments to measure the pH of lime-stabilized biosolids without creating slurries. The standard deviation of 15 pH measurements at different locations in a biosolid sample was used to assess mixing quality. The bench-scale experimental study showed that well-mixed limed biosolids had consistently high pHs (approximately 12) with low standard deviations (< 0.5 pH units), whereas poorly mixed biosolids had areas with low pH (< 10) and high standard deviations (> 2 pH units). Poorly mixed biosolids exhibited rapid and marked pH reduction, as well as offensive odor generation, whereas well-mixed biosolids resisted pH reduction and offensive odor generation. The full-scale study aimed at improving lime incorporation and biosolids quality confirmed the use of a flat surface pH electrode to capture low pH regions in biosolids that were masked by the current slurry method.  相似文献   

15.
Preparation of activated carbon from sewage sludge is a promising way to dispose of sewage sludge as well as to produce a low-cost adsorbent for pollutant removal. This research work aimed to optimise the condition for activated carbon preparation from anaerobically digested sewage sludge with the additive coconut husk. The sewage sludge sample was mixed with the additive coconut husk. The preparation condition variables investigated involved the concentration of the ZnCl2 solutions, heating temperature, dwell time and heating rate in pyrolysis and the mixing ratio of coconut husk to sewage sludge. Surface area, pore size distribution, aqueous phenol adsorption capacity and the production yield of the final products were determined and compared. Experimental results revealed that low concentrations of ZnCl2 solution tended to improve the microporosity of the final product. Heating temperature had a considerable impact on the surface area, pore size distribution and phenol adsorption capacity of the final products, whereas dwell time and heating rate performed comparatively insignificantly. The effect of increasing the mixing ratio of coconut husk to sewage sludge was principally to increase the microporosity of the final products. The activated carbon with the highest BET surface area was produced with the activation of 5 M ZnCl2 solution and, thereafter, pyrolysis at a heating temperature of 500 degrees C for 2 h with a heating rate of 10 degrees C/min. The mixing ratio of 1:4 in terms of coconut husk to sewage sludge based on their dried weights was found to be most cost effective.  相似文献   

16.
Abstract

Uniform lime incorporation into sewage sludge is critical for biosolid lime stabilization processes. There is no class B biosolids regulation for lime incorporation. The slurry method is currently used to evaluate the pH of limed biosolids, but this method homogenizes the biosolids and potentially masks poor lime mixing. In this study, a flat-surface pH electrode was used in bench-scale and full-scale experiments to measure the pH of lime-stabilized biosolids without creating slurries. The standard deviation of 15 pH measurements at different locations in a biosolid sample was used to assess mixing quality. The bench-scale experimental study showed that well-mixed limed biosolids had consistently high pHs (~12) with low standard deviations (<0.5 pH units), whereas poorly mixed biosolids had areas with low pH (<10) and high standard deviations (>2 pH units). Poorly mixed biosolids exhibited rapid and marked pH reduction, as well as offensive odor generation, whereas well-mixed biosolids resisted pH reduction and offensive odor generation. The full-scale study aimed at improving lime incorporation and biosolids quality confirmed the use of a flat surface pH electrode to capture low pH regions in biosolids that were masked by the current slurry method.  相似文献   

17.
The reduction of organic and nitrogen pollution of wastewater was investigated in two hybrid reactors and compared with the reduction obtained by using a conventional activated sludge reactor (ASR) run as a control. Both HR-1 and HR-2 were activated sludge systems where a low-density carrier, P1 (polyethylene) for HR-1 and P2 (recycled plastics) for HR-2, was added. Firstly, the three reactors were operated at 10 days Suspended Solid Retention Time (SRT(SS)), leading to a complete nitrification. Secondly, the SRT(SS) for each reactor was lowered to 3 days. Nitrification was lost for the ASR but remained complete for HR's. Respirometric techniques were used to measure fixed or suspended biomass activities for heterotrophic and autotrophic biomass. More than 90% of the autotrophic activity was found on the supports whatever the SRT(SS) used. The results may underline the role of the carrier geometry or surface characteristics on the autotrophic/heterotrophic microorganism distribution.  相似文献   

18.
Anderson Td  MacRae JD 《Chemosphere》2006,62(7):1153-1160
Polybrominated diphenyl ethers (PBDEs) are one class of flame retardants commonly used in textiles, foams and plastics. They are similar in behavior to the well-studied polychlorinated biphenyls and growing evidence suggests they are widespread global environmental pollutants that are capable of bioaccumulation. Fish tissue samples were collected from sites along the Penobscot River in central Maine. The total concentration of tetra- to hepta-PBDEs in these samples were calculated and generally increased from upstream to downstream locations ranging from 800 to 1810 ng/g lipid at the northernmost site to 5750-29000 ng/g at the downstream sampling site. BDE-47, 99 and 100 were the predominant congeners found in the fish tissue. Wastewater treatment plants (WWTPs) are one of the potential sources of these compounds to the environment through effluent discharge and landspreading of biosolids. Influent, effluent, activated sludge and dewatered biosolids were collected and analyzed for PBDE congeners from a WWTP at Orono, Maine. PBDE congeners were detectable in effluent samples at concentrations from 0.31 to 0.90 microg/l, in the activated sludge at 1.32-3.8 microg/l and in the influent at 4.2-4.3 microg/l, but the majority of the material was concentrated in the biosolids. Total concentration in the biosolids was 2320-3530 microg/kg dry weight.  相似文献   

19.
This study selected biosolids from a petrochemical waste-water treatment plant as the raw material. The sludge was immersed in 0.5-5 M of zinc chloride (ZnCl2) solutions and pyrolyzed at different temperatures and times. Results indicated that the 1-M ZnCl2-immersed biosolids pyrolyzed at 500 degrees C for 30 min could be reused and were optimal biosolid adsorbents for benzene adsorption. Pore volume distribution analysis indicated that the mesopore contributed more than the macropore and micropore in the biosolid adsorbent. The benzene adsorption capacity of the biosolid adsorbent was 65 and 55% of the G206 (granular-activated carbon) and BPL (coal-based activated carbon; Calgon, Carbon Corp.) activated carbons, respectively. Data from the adsorption and desorption cycles indicated that the benzene adsorption capacity of the biosolid adsorbent was insignificantly reduced compared with the first-run capacity of the adsorbent; therefore, the biosolid adsorbent could be reused as a commercial adsorbent, although its production cost is high.  相似文献   

20.
Performance and stability of two-stage anaerobic digestion.   总被引:1,自引:0,他引:1  
The stability, capacity, and solids destruction efficiency of single versus two-stage anaerobic digestion was studied in bench-scale reactors using combined waste activated and primary sludge. Laboratory staged mesophilic digesters showed an improved volatile solids and volatile suspended solids destruction efficiency over a single-stage system (at the same total solids retention time [SRT]) of approximately 3.2 and 5.8 percentage points, respectively. To quantify stability and capacity, a new digester monitoring method was introduced that measured the digester maximum acetate utilization capacity, V(max,ac), and was used to investigate the potential for digester instability at different transient loadings. The ratio of the V(max,ac) value to the estimated acetate production rate for a given digester loading was termed the acetate capacity number (ACN). Values greater than 1.0 indicate excess acetate utilization capacity. The first stage of the laboratory two-stage mesophilic system (10-day SRT for each stage) had an ACN number of 1.3 compared with a value of 1.8 for the single-stage 20-day SRT digester. Thus, while a staged mesophilic system can improve solids destruction efficiency, it demonstrates a lower capacity for metabolizing highly variable loads.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号