首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 16 毫秒
1.
The concentrations of ammonium NH4+, nitrate NO3-, and nitrite NO2- ions were recorded along with ammonia (NH(3)) emission from a fertilized rice field located in the Kwangju province in South Korea over a period of 4 months (June to October 2006). The highest magnitude of NH(3) flux was 20,754 microg m(-2) h(-1), while the average flux value over the entire sampling period was 2,395 microg m(-2) h(-1). The highest ionic concentrations were 1.67, 0.44, and 0.71 ppm for NH4+, NO3-, and NO2- ions, respectively. Possible effects of soil pH on NH(3) fluxes were detected, as they concurrently exhibited a gradual and periodic change during the sampling period. Positive correlations existed between concentrations of NH4+ and NO2- ions and the soil pH. Positive correlations also existed between NH(3) emission flux and ambient (and water) temperatures. Results indicated that fertilizer application to rice can lead to significant emission of NH(3) along with NH4+ and NO3- ions.  相似文献   

2.
通过对新疆12个监测点氮沉降研究结果发现,无机活性氮浓度(p NH 4+、p NO 3-、NH 3、NO 2)在不同生态系统存在较大的时空差异,氮沉降通量变化随人为干扰程度呈递增趋势。总结了当前新疆大气氮沉降监测研究进展,包括主要监测方法、不同生态系统大气氮素干沉降的时空差异性分析、大气氮素干湿沉降通量估算。对大气氮素干湿沉降通量的整体估算、不同生态系统的监测常态化等还存在不足,未来评估氮沉降的综合气候效应、定量临界负荷以及生态系统对氮沉降通量急剧增加的响应是今后研究的重点方向。  相似文献   

3.
Emissions of NOx and SO2 were monitored in the presence of ammonia liquor in a 0.09 m2 and 2 m high stainless-steel fluidized-bed combustor. Experiments were carried out at 2 m/s fluidizing velocity, 40% excess air, and 870 °C bed temperature. Ammonia liquor with 7% ammonia by weight was injected into the freeboard of the combustor 52 cm above the distributor through a water-cooled injector. A 65 : 34 primary/secondary air ratio was maintained throughout the investigation. Approximately 70% of NO and 20% of SO2 was reduced at an NH3/NO molar ratio of 2 : 1, respectively. However, a higher reduction in SO2 emissions (62%) was achieved at a very high NH3/NO molar ratio of 7 : 1. These experiments showed that ammonia addition did have a significant effect in SO2 reduction if injected in an excess amount. The injection of ammonia liquor combined with staged combustion was found to be very effective in reducing NOx emissions. A reduction of about 50% was achieved at an NH3/NO molar ratio of 0.6 : 1 which is also coupled with a very low level of ammonia in the flue.  相似文献   

4.
Nitrate (NO(3)(-)) is a commonly found contaminant in groundwater and surface water. It has created a major water quality problem worldwide. The laboratory batch experiments were conducted to investigate the feasibility of HCl-treated zero-valent iron (Fe(0)) combined with different adsorbents as hybrid systems for simultaneous removal of nitrate (NO(3)(-)) and ammonium (NH(4)(+)) ions from aqueous solution. The maximum NO(3)(-) removal in combined Fe(0)-granular activated carbon (GAC), Fe(0)-filtralite and Fe(0)-sepiolite systems was 86, 96 and 99%, respectively, at 45 °C for 24 h reaction time. The NO(3)(-) removal rate increased with the increase in initial NO(3)(-) concentration. The NO(3)(-) removal efficiency by hybrid systems was in the order of sepiolite > filtralite > GAC. The NH(4)(+) produced during the denitrification process by Fe(0) was successfully removed by the adsorbents, with the removal efficiency in the order of GAC > sepiolite > filtralite. Results of the present study suggest that the use of a hybrid system could be a promising technology for achieving simultaneous removal of NO(3)(-) and NH(4)(+) ions from aqueous solution.  相似文献   

5.
基于Berthollet反应示波极谱法测定水中微量氨   总被引:1,自引:0,他引:1  
在亚硝基铁氰化钾存在下,氨在氢氧化钠介质中与苯酚、次氯酸钠反应,其产物靛酚在滴汞电极上产生-灵敏的吸附波,NH3-N在0.003~0.22mg/L内,导数峰电流与其呈良好的线性关系。用于环境水中NH3-N的测定,其相对标准偏差小于3%,回收率为97%~105%,方法具有较好的选择性。  相似文献   

6.
In this paper, a new algorithm for nitric oxide (NO) measurement based on multi-scale wavelet decomposition is proposed. The algorithm uses one-dimensional discrete multi-scale wavelet decomposition to analyze the transmission spectrum of flue gas. Through the different scales of decomposition, the relation between the absorption characteristics of NO gas and the reconstruction of wavelet coefficients is found. The DB9 wavelet can obtain the most obvious absorption characteristics of the NO gas. After calibration, the algorithm is used to measure the concentration of the mixture of NO and SO(2). The results show that the algorithm is efficient towards SO(2) absorption interference with a full-scale error less than ± 0.4% in laboratory conditions. The algorithm was then applied to field measurements with an overall standard deviation of 8.37 mg m(-3), which is better than 18.92 mg m(-3) determined by the least squares method. Under the interference of desulfurization, the full-scale measurement errors are less than ± 2%. In addition, the algorithm avoids using the reference spectrum, thereby reducing the aging of the light source effectively. It has strong anti-interference capability, good durability, and practicality in the continuous monitoring of NO.  相似文献   

7.
为了研究在线离子色谱法测定大气PM2.5中NH4^+、NO3^-、SO4^2-的不确定性来源,探讨了标准曲线的浓度范围及浓度梯度设置对离子浓度结果的影响,并对标准曲线设定方案进行了优化。结果表明:不同浓度范围的标准曲线对于NH4+的浓度结果有较大的影响,存在1. 87%~14. 91%的偏差,对于NO3^-、SO4^2-的影响较小,相对偏差分别为2. 94%和2. 82%;非均匀布点和均匀布点标准曲线定量NH4+的结果存在4. 15%~4. 25%的偏差,对于NO3^-和SO4^2-,相对偏差分别为0. 10%和5. 99%。对于二次拟合的NH4^+,在样品浓度波动较大时,可以将样品划分为低浓度范围和高浓度范围,分别选用低浓度段标准曲线和高浓度段标准曲线,以期得到更合理的浓度结果。  相似文献   

8.
采用在线单颗粒气溶胶质谱技术源解析方法,对桂林市PM2.5典型排放源的粒径和化学成分进行质谱分析,采集燃煤/燃气源、工业工艺源、扬尘源、油烟源4类共计7个典型排放源。结果表明,桂林市4类排放源细颗粒物的粒径分布为0.25~1.25μm,80%以上的细颗粒分布在0.2~1.0μm的小粒径范围,峰值约0.68μm。细颗粒物离子成分含有Na~+、Mg~+、K~+、NH~+4、Fe~+、Pb~+、Cd~+、V~+、Mn~+、Li~+、Al~+、Ca~+、Cu~+、Zn~+、Cr~+、CN~-、PO_3~-、NO_2~-、NO_3~-、Cl~-、SO_4~(2-)、SiO_3~-等成分,桂林市细颗粒物为元素碳、有机碳元素碳、有机碳、富锰颗粒、富铁颗粒、富钾颗粒、矿物质、左旋葡聚糖以及其他金属等9类。  相似文献   

9.
Contents of inorganic nitrogen (NH4(+)-N and NO3(-)-N) in soil profiles were measured in five typical zones ( including permanently flooded floodplain(B), 1-year floodplain (O), 5-year floodplain (F),10-year floodplain (T), and 100-year floodplain (H) )from Huolin River floodplain in Erbaifangzi, Jilin Province of China, in the soil-defrosted period (Mayof 1999). Contour maps and profile maps were constructed to describe the spatial distributions of NH4(+)-N and NO3(-)-N) in order to identify the influences of flood frequencies on them. Results showed that NH4(+)-N generally increased with depth in soil profiles from the five areas, but NH4(+)-N contents in T or H areas significantly differed from those in other areas. For NO3(-)-N, with the exception that there was a significant cumulative peak (6.77 +/- 0.08 mg kg(-1)) at 15-cm depth (10-20 cm) in B area, no significant difference was observed between NO3(-)-N contents in soil profiles from the other four areas. The horizontal distributions of NH4(+)-N and NO3(-)-N in top soils (0-10 cm) were different in the five areas,which were greatly influenced by flood frequencies. The highest content of NH4(+)-N or NO3(-)-N did not appear in B area but in the floodplain with certain flood frequency. For example, NH4(+)-N content (16.81 mg kg-(1)) in 5-year floodplain wetland was highest, and the highest content of NO3(-)-N(1.69 mg kg(-1)) appeared in 1-year floodplain wetland. In addition, NH4(+)-N contents were significantly correlated with soil pH, and NO3(-)-N contents had significant correlation with inorganic carbon, but there were no significant correlations between inorganic nitrogen and other selected soil properties.  相似文献   

10.
Passive samplers were used to monitor ammonia concentrations at rural inner alpine and pre-alpine, as well as urban, sites in Austria and Bavaria. Elevated concentrations were measured both at farms (up to 36 microg NH3 m(-3)) and at urban locations (up to 28 microg NH3 m(-3)). At urban locations a linear relationship between the traffic density and the NH3 concentration was found, but there was no marked seasonal trend. The highest ammonia concentrations were measured in a traffic tunnel (up to 78 microg NH3 m(-3)). The presence of livestock breeding or small scale alpine pastures resulted in elevated concentrations at the rural sites (8.1-12 and 2.5-4.6 microg NH3 m(-3), respectively), compared to the surrounding areas (3.1 and 0.9 microg NH3 m(-3)). Agriculture related sources are usually limited either spatially or seasonally. As the emissions were moderate in our case, a rapid removal and dilution of ammonia was possible and therefore the NH3 burden was only local. Sources related to traffic are more evenly distributed both geographically and seasonally. The WHO guideline, annual average concentration of 8 microg m(-3) for the protection of vegetation, was only exceeded at farms, at the urban station with the heaviest traffic and in the Tauerntunnel.  相似文献   

11.
To reduce SO2 emissions, ammonia gas was injected into a coal-fired fluidized-bed combustor under staged commbustion condition. The combustor was 2 m high with a 30 cm static bed height and a freeboard height of 170 cm. The ammonia gas was injected at 52 cm and 65 cm above the distributor, which had a temperature of ca. 700 °C, by an uncooled stainless-steel tube injector. The experiments investigated the effects of ammonia gas injection on sulphur dioxide emissions at staged conditions, varying the: (i) excess air level, (ii) secondary air ratio, (iii) fluidizing velocity, (iv) ammonia injection position, and (v) the ammonia : sulphur dioxide molar ratio.A maximum reduction of 66% in SO2 emissions was found at 40% excess air, 65 : 35 staging, 1.5 m/s fluidizing velocity, 65 cm injection height, and an NH3 : SO2 molar ratio of 1.2. The onset of SO2 reduction occurred at an NH3 : SO2 ratio of 0.5. The fluidizing velocity, excess air, level of staging, and ammonia injection height all have a significant influence on SO2 reduction.It is difficult to determine how the SO2 reduction varies with the operating conditions when ammonia is injected in the high temperature zone of the combustor. As sulphur oxides-ammonia reactions are low temperature reactions, the findings confirm the occurrence of reactions above the freeboard or near the exit to the cyclone.  相似文献   

12.
Gaseous ammonia (NH3) is an important form of N deposition to ecosystems, but it is not being routinely monitored in Switzerland. Therefore, a study was conducted to estimate annual means and seasonal patterns of NH3 concentrations for different site types in Switzerland, and to compare annual measured and modelled NH3 concentrations. NH3 concentrations were measured using the 'Zürcher' passive sampler, a Palmes type sampler with an acidic solution as absorbent. Twenty-four sampling sites were run for one year, and 17 for two years. The samplers were changed fortnightly or monthly. Spatial emission patterns were mapped by combining information on (1) the location of emission sources, (2) national statistics on NH3-emitting activities and (3) activity-specific emission factors. The spatial resolution was one hectare. The mean annual NH3 concentration in the ambient air of the 41 sites was 2.5+/-0.3 microg m(-3) (mean+/-standard error). It ranged from 0.4 to 7.5 microg m(-3). The site type and the season were the most important factors explaining the variation in the seasonal mean concentration. NH3 concentrations were highest in intensively used agricultural areas and in cities, and lowest in Alpine sites remote from emission sources. At 39 out of 41 sites, the NH3 concentrations were higher in summer (3.1+/-0.3 microg m(-3)) than in winter (2.0+/-0.3 microg m(-3)). Modelled NH3 concentrations did not systematically deviate from measured concentrations (r2 = 0.69). With the combined monitoring and modelling approach, it is now possible to obtain a reasonable and consolidated picture of the overall NH3 situation in Switzerland.  相似文献   

13.
Determination of emission of contaminant gases as ammonia, methane, or laughing gas from natural ventilated livestock buildings with large opening is a challenge due to the large variations in gas concentration and air velocity in the openings. The close relation between calculated animal heat production and the carbon dioxide production from the animals have in several cases been utilized for estimation of the ventilation air exchange rate for the estimation of ammonia and greenhouse gas emissions. Using this method, the problem of the complicated air velocity and concentration distribution in the openings is avoided; however, there are still some important issues remained unanswered: (1) the precision of the estimations, (2) the requirement for the length of measuring periods, and (3) the required measuring point number and location. The purpose of this work was to investigate how estimated average gas emission and the precision of the estimation are influenced by different calculation procedures, measuring period length, measure point locations, measure point numbers, and criteria for excluding measuring data. The analyses were based on existing data from a 6-day measuring period in a naturally ventilated, 150 milking cow building. The results showed that the methane emission can be determined with much higher precision than ammonia or laughing gas emissions, and, for methane, relatively precise estimations can be based on measure periods as short as 3 h. This result makes it feasible to investigate the influence of feed composition on methane emission in a relative large number of operating cattle buildings and consequently it can support a development towards reduced greenhouse gas emission from cattle production.  相似文献   

14.
Total suspended particulate (TSP) samples were collected during wintertime from November 24, 1998 to February 12, 1999 in Beijing. Ionic species including Cl-, NO3(-), SO4(2-), Na+, NH4(+), K+, Mg2+ and Ca2+ were determined by Ion Chromatography (IC). The sum average concentration of all the determined ions accounted for 18.9% of the TSP concentration, and SO4(2-) appeared the dominant ion with an average concentration of 30.84 microg m(-3); the sum mass concentration of SO4(2-), NO3(-), Ca2+ and NH4(+) accounted for about 83.2% of all the eight ions measured. The study indicated that the chemical form of sulfate and ammonium varies with TSP concentration levels. During heavy pollution periods, the average TSP concentration was 0.66 mg m(-3), and the NH4(+)/SO4(2-) molar ratio was low (0.58). It indicated that sulfate may present as CaSO4 and (NH4)2SO4 x CaSO4 x 2H2O. When TSP concentration (average 0.186 mg m(-3)) was relatively low, the NH4(+)/SO4(2-) molar ratio was 1.94, close to the theoretical ratio of 2 of (NH4)2SO4. Under this condition (NH4)2SO4 is expected to exist as the major form of sulfate. When the TSP concentration level was medium (average 0.35 mg m(-3)), the NH4+/SO4(2-) molar ratio appeared an average value (1.27), (NH4)2SO4, (NH4)2SO4 x CaSO4 x 2H2O and CaSO4 are expected to be present in those aerosol particles. Meteorological conditions including wind speed and wind direction were related to the TSP concentration level.  相似文献   

15.
The Helsinki Metropolitan Area Council (YTV) is responsible for air quality monitoring in the Helsinki area. Air quality has been monitored periodically since the late 1950s. An automatic SO2 monitoring network was constructed in 1975 and TSP measurements were added in 1978. Since then the network has been expanded and currently five automatic multicomponent stations form the basis of the network monitoring SO2, NO, NO2, CO, PM10 and O3 concentrations. Manual TSP and PM10 measurements are also conducted. Mobile monitoring units are also being used as well as special measurement campaigns. The effects of air pollution on nature are studied in bioindicator monitoring. An air quality index is used in order to inform the public of the current air quality situation. Changes in air quality are reflected in monitoring strategy. SO2 concentrations have decreased in the past two decades. Annual averages in 1995 were at or below 5 µg/m3. Traffic is the major source for pollutants even though catalytic converters have lowered traffic emissions somewhat. The highest annual average NO2 concentration at an urban site was 49 µg/m3 in 1995, and there has been no clear change in NO2 levels. There has been a decreasing trend in CO concentrations. Maximum annual TSP and PM10 averages in 1995 were 92 and 32 µg/m3, respectively. The highest average lead concentration was 0.01 µg/m3. Elevated concentrations are experienced from time to time. During the spring daily TSP and PM10 concentrations can go up to around 300 and 150 µg/m3, respectively. This is caused by resuspension mainly due to street sanding. Also a major winter NO2 episode occurred in December 1995. The highest hourly NO2 concentrations reached 400 µg/m3.  相似文献   

16.
固定污染源氨气的手工监测,干扰因素较多,其中采样环节尤为关键。实验通过催化氧化-化学发光法考察不同采样管线材质对氨气的吸附效果,离子色谱法考察化学吸收法采集氨气的吸收瓶类型、采样流量、吸收液种类、吸收液浓度及体积等采样条件对氨气吸收效率的影响。实验表明,316 L不锈钢与聚四氟乙烯对氨气的吸附较小,氨气的采样流量不宜超过1.0 L/min,棕色气泡式吸收瓶更适用于氨气样品的采集,磷酸溶液作吸收液对氨气的吸收效率较好,对于低浓度的氨气样品,应采用低流量长时间采集。  相似文献   

17.
Odorous air samples collected from several sources were presented to an olfactometer, an electronic nose, a hydrogen sulfide (H(2)S) detector and an ammonia (NH(3)) detector. The olfactometry measurements were used as the expected values while measurements from the other instrumentation values became input variables. Five hypotheses were established to relate the input variables and the expected values. Both linear regression and artificial neural network analyses were used to test the hypotheses. Principal component analysis was utilized to reduce the dimensionality of the electronic nose measurements from 33 to 3 without significant loss of information. The electronic nose or the H(2)S detector can individually predict odor concentration measurements with similar accuracy (R (2) = 0.46 and 0.50, respectively). Although the NH(3) detector alone has a very poor relationship with odor concentration measurements, combining the H(2)S and NH(3) detectors can predict odor concentrations more accurately (R (2) = 0.58) than either individual instrument. Data from the integration of the electronic nose, H(2)S, and NH(3) detectors produce the best prediction of odor concentrations (R (2) = 0.75). With this accuracy, odor concentration measurements can be confidently represented by integrating an electronic nose, and H(2)S and NH(3) detectors.  相似文献   

18.
北京市河流氨氮浓度时空演变特征分析   总被引:1,自引:1,他引:0  
选取2010—2017年北京市地表水监测数据,对河流氨氮(NH 3-N)浓度的时空演变特征进行分析。结果显示,空间上,全市河流NH 3-N浓度整体上保持上游优于下游的分布特征;年均浓度显著下降,由2010年的8.53 mg/L逐年下降至2017年的3.09 mg/L;河流NH 3-N浓度与化学需氧量、总磷呈显著正相关,与溶解氧显著负相关,总氮与NH 3-N的比值随着水质由差到好呈上升状态。污水收集处理和再生水利用是改善北京市河流水质的关键措施。为持续降低河流NH 3-N浓度,改善首都水环境质量,须提高污水处理能力和出水水质,有机结合再生水回用与生态治水理念。  相似文献   

19.
A Gas Particle Partitioner (GPP) that allows highly efficient separation of gas and particles with no effect on the thermodynamic conditions and substantially no change of the gas composition has been developed. The GPP is a coaxial arrangement with inner and outer electrodes and utilizes a corona discharge to electrically charge the particles and a strong electric field to remove them from the sample flow. Several measures were taken to avoid an influence of the corona discharge on the gas composition. The GPP can be applied for various applications. This paper focuses on the use of the GPP as a pre-filter for gas analyzers, where zero pressure drop and a minimization of the influence of the corona discharge on the gas composition are the main objective. Due to its design, the GPP introduces no changes to the thermodynamic conditions. However, corona discharge is known to produce significant amounts of ozone and oxides of nitrogen. The effect of the corona on the gas composition of the sample flow was determined under various conditions. The gas concentrations strongly depended on several aspects, such as material and diameter of the corona wire and polarity of the corona voltage. Due to the measures taken to minimize an effect on the gas composition, the concentrations of these gases could effectively be reduced. Along with the maximum gas-particle separation efficiency of near 100%, the additional O3 concentration was 42 ppbV and the additional NO2 concentration 15 ppbV. If an efficiency of 95% is acceptable, the added concentrations can be as low as 2.5 ppbV (O3) and 0.5 ppbV (NO2), respectively.  相似文献   

20.
In this study, the environmental behavior of malodor pollutants (MPs) [including reduced sulfur compounds (RSCs)] and aromatic volatile organic compounds (AVOCs) were investigated around urban valley areas during several field campaigns (February through December 2006). The MPs measured in the study area include the RSCs (H(2)S, CH(3)SH, DMS, and DMDS), ammonia (NH(3)), and styrene (STY); the AVOCs include benzene (BEN), toluene (TOL), ethylbenzene (EB), m,p-xylene (MPX), and o-xylene (OX). The variation of most MP concentrations (except for DMDS) was found to be larger than that of AVOCs. It was found that STY (2,346 +/- 4,867 ppbv) was the most dominant MP followed by NH(3) (447 +/- 285), CH(3)SH (16 +/- 41), and the others (<8). The magnitude of AVOCs was found in the following descending order: TOL (1.4 +/- 2.2 ppbv), EB (1.0 +/- 2.1), MPX (0.9 +/- 2.0), and the others (<0.8). The concentration levels of most MPs on industrial (I) and downwind (D) sites were up to an order of magnitude higher than those at non-industrial (N) and upwind (U) sites. For most AVOCs, the former was ~3 times higher than the latter. For malodor intensity in RSCs, CH(3)SH was the dominant contributor. The concentration difference in target compounds between the sites/periods is likely to be caused by the combined effects such as emission sources, geographical features (e.g., semi-closed topography), and meteorological conditions (e.g., wind directions) in and outside the urban valley.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号