首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ABSTRACT

This paper discusses about the effect of feeder height and heat flux on the heat transfer characteristics of horizontal tube falling film evaporation in the thermal regimes. In order to investigate this, a two- dimensional CFD model was developed to perform simulation and results were compared and validated with published data available in the literature. Heat transfer co-efficients in the thermal regimes were determined from the CFD simulation and the results were recorded, analyzed and validated with the mathematical models available in the literature. The novelty of the current study is to predict the commencement of the fully developed thermal region over the tube from the simulation model under varying feeder height and heat flux. An effort was also made to measure the liquid film thickness around the tube from the CFD model in the thermal regimes. It is observed that angle of thermally developing region contracts and fully developed thermal region extends with the increase of the feeder height and heat flux. It is observed from the study that increase of heat flux by 10 kW/m2 resulted in increase of heat transfer co-efficient value by 10–12% average in thermally developing region and 12–15% average in fully developed region. Thinnest liquid film thickness observed between 85 and 127°angle. Shifting of thinnest region of liquid film upward from the mid tube with the increase of the feeder height and heat flux is noted.  相似文献   

2.
An experimental investigation is presented in this paper on the vapor compression refrigeration cycle used in an ice-making machine with a multi-channel evaporator. To study the operation performance of the refrigeration system in the ice-making machine, the fluid temperature distribution in multi-channel evaporating coils are tested and the dynamic variations in each cooling loop are investigated during the ice-generating phase. The results show that the external cooling loops have the largest temperature fluctuations caused by the large initial refrigerant injecting mass flow and the external environmental disturbances. For the inner cooling loops, the related temperature profiles of different test points have relative stable variations. To reduce the temperature fluctuations of the outside loops, it is suggested to reduce the initial refrigerant mass flow and adjust the initial opening of the thermal expansion valve. Moreover, it is the normal phenomenon for the slight temperature variations for the temperature curves of different test points, caused by the adjustment of thermal expansion valve. During the ice-making process, both the sensible heat removal phase and latent heat removal phase are experienced successively. To remove the sensible heat of water, the refrigerant system is operating in high efficiency with test points having a rapid linear temperature reduction. While for eliminating the latent heat of ice, it requires much more power supply, the relating test points have a temperature decrease with fluctuations. To improve the operation performance of ice machine, some suggestions and improvements are proposed.  相似文献   

3.
This study examines energetic and exergetic performances of display cases’ units used in market applications depending on different refrigerants. Besides CO2 emission potential of each refrigerant based on exergetic irreversibility obtained from analyses is calculated by the method of Total Equivalent Warming Impact (TEWI). In this study, 1 kW cooling capacity and vapor compression cooling cycle is taken as reference and refrigerants of R-22, R-134a, R-404A, and R-507 together with alternative refrigerant R-407C and R152a are examined separately. According to analyses, R-404A gas, used widely in market applications, has low performance with average COP 3.89 and average exergy efficiency 55.20%. R-152a gas has the best performance by the thermodynamics parameters including COP 4.49, exergy efficiency 63.79%, and 0.23 kW power consumption and emission parameter 14097.490 ton CO2/year. Although COP is used as a criterion to evaluate the systems, this study finally emphasizes the importance of exergy analysis and TEWI method which are important methods to determine irreversibility and emission potential of the systems.  相似文献   

4.
ABSTRACT: Growing‐season evapotranspiration and surface energy and water balances were investigated for an extensive, bulrush‐dominated wetland in the Upper Klamath National Wildlife Refuge of south‐central Oregon, a semi‐arid region with competing demands for scarce water resources. Turbulent fluxes of sensible and latent heat were measured by eddy covariance for 1.2 to 1.9 days during each of four site visits during late‐May to mid‐October 1997. Mean daytime latent heat flux and the Bowen ratio ranged from 148 to 178 W m?2 and from 0.38 to 0.51, respectively, during late May, mid‐July, and late August site visits. By mid‐October, when the plant canopy had senesced, daytime latent heat flux and the Bowen ratio averaged 46 W m?2 and 2.8, respectively. An hourly Penman‐Monteith (PM) model that was fitted to the surface‐flux data provided values for the surface resistance to water‐vapor diffusion that ranged from 78 s m?1 during late August to 206 s m?1 during mid‐October. Similarly, a Priestley‐Taylor (PT) model provided values for the PT multiplier (a) that ranged from 0.96 during late August to 0.37 during mid‐October. The PM and PT models predicted evapotranspiration totals of 560 and 480 mm, respectively, for May 28 to October 12, 1997.  相似文献   

5.
Urbanization has a great impact on urban evapotranspiration. Water evaporation inside buildings is an important part of urban water vapor resources and a crucial core of urban hydrological processes. The systematic studies on building water evaporation (BWE) are mostly the method of experimental monitoring. This study proposed a new method to simulate and estimate water evaporation flux inside buildings in urban areas. Based on the nighttime light data and urban per capita gross domestic product (GDP), a new modeling system was built to simulate the total BWE. Building area was calculated using the nighttime light data. And the BWE coefficient Df was estimated according to the important indicator of economic development per capita GDP value. Then the water evaporation inside urban buildings and the spatial distribution of water evaporation inside buildings in typical cities could be obtained. The results showed that the total amount of water evaporation inside buildings in China's urban areas was 24.5 billion m3. Among the 31 provincial capitals in China, Shanghai had the largest BWE of 1.08 billion m3. The minimum water evaporation of buildings in Lhasa was 20.0 million m3. Studies of BWE can assess urban water budgets, support on-demand allocation of water resources, and provide a fundamental understanding of the relationship between water resources and energy heat island effects in urban areas.  相似文献   

6.
An untreated sewage source heat pump system directly makes use of the urban raw sewage instead of that treated by a sewage plant. At present In China, most systems adopt the indirect mode for avoiding the harmful effect of the sewage on the heat pump unit. In this article a direct-mode untreated sewage source heat pump system, which shows less theoretical analysis of the mathematical model, is theoretically designed and analyzed to simulate the system dynamic characteristics in the heating mode. The results show that the system COP changes from 4.1 to 3.4 and the heating capacity from 9.5 to 15.3 kW when the sewage inlet temperature is 12°C and the frequency increases from 18 to 32 HZ. The condenser heat-transfer coefficient increases with the frequency reducing while the change trend of evaporator heat-transfer coefficient is the opposite. The highest values of them are 303 and 1617 W.m?2?K?1, respectively. The frequency control simulation supplies the operation adjustment with theoretical instructions and some reference values.  相似文献   

7.
In this study, an experimental investigation on the performance of a small-scale residential-size solar-driven adsorption (silica gel-water) cooling system that was constructed at Assiut University campus, Egypt is carried out. As Assiut area is considered as hot, arid climate, field tests for performance assessment of the system operation during the summer season are performed under different environmental operating conditions. The system consists of an evacuated tube with a reflective concentration parabolic surface solar-collector field with a total area of 36 m2, a silica gel-water adsorption chiller of 8 kW nominal cooling capacity, and hot and cold water thermal storage tanks of 1.8 and 1.2 m3 in volume, respectively. The results of summer season field test show that under daily solar insolation varying from 21 to 27 MJ/m2, the solar collectors employed in the system had high and almost constant thermal efficiency. The daily solar-collector efficiency during the period of system operation ranged from about 50% to 78%. The adsorption chiller performance shows that the chiller average daily coefficient of performance (COP) was 0.41 with the average cooling capacity of 4.4 kW when the cooling-water and chilled-water temperatures were about 31°C and 19°C, respectively. As the chiller cooling water is cooled by the cooling tower in the hot arid area, the cooling water is at a higher temperature than the design point of the chiller. Therefore, an experiment was carried out using the city water for cooling. The results show that an enhancement in the chiller COP by 40% and the chilling power by 17% has been achieved when the city water was 27.7°C.  相似文献   

8.
ABSTRACT

Refrigerant pressure drop and temperature change in pipes are normally ignored in the thermodynamic analysis of traditional vehicle air conditioning system, this will result in serious errors. In this Paper, pressure drop and temperature difference are simulated in different pipes of electric vehicle (EV) heat pump system to analysis the effects of pipes in the actual EV heat pump system. The results indicate that the greater the mass flow, the faster pressure drop increases, the temperature difference decreases. Pressure drop of saturated liquid refrigerant is smaller than that of saturated gas refrigerant at the same saturation pressure and mass flow rate. The higher the refrigerant pressure (no phase change), the slower pressure drop decreases, the faster the temperature difference decreases. Pressure drop decreases with the increment of bending angle of the pipe. For EV heat pump system, suitable valves and less branches are helpful for energy saving of the system. Shortening the pipe between compressor and condenser can reduce temperature change obviously. Pressure drop per unit length in the pipe between evaporator and compressor is large especially in heating mode because of lower refrigerant density. It even reaches to over 100 times of that in the pipe between condenser and throttle valve in heating mode and has negative effects on the performance of the system. If the evaporator is closer to the compressor and the number of branches is less, then pressure drop will decrease a lot, which will be advantageous for energy saving of the heat pump system.  相似文献   

9.
This study examines parametric approaches to the calculation of refrigerant-based CO2 emissions in different cooling areas. Both the exergy analyses of refrigerants, used in domestic, commercial, transportation and industrial applications, and the environmental performances regarding exergetic irreversibility are investigated separately. Then, CO2 emissions caused by systems are examined via two different parameters, I°) Environmental Impact Factor and ??°) Integrated Impact Factor (CIF). The study is based on a vapor compression cooling cycle model, commonly preferred by cooling applications, and the analyses have been made for 1 kW cooling capacity in relation to evaporator temperatures of the systems. In all cooling application, R134A gas stands out among the others in terms of coefficient of performance and exergy efficiency. Moreover, both emission analyses show that it has the lowest emission value. The paper concludes with an evaluation of the reasons for the refrigerant choice, the design and the selection of such a system, and why exergetic and environmental parameters should be preferred.  相似文献   

10.
A phase change material (PCM)-based flat plate modular heat exchanger for free cooling application, suitable for the diurnal temperature variation that prevails during the summer months of Bangalore city, India is designed and experimentally investigated. The flow and other parameters selected in the present study are meant to suit the accelerated charging of the PCM in the modular heat exchanger during the early morning hours, and to provide cool energy to the room during the daytime, by circulating the ambient air through the heat exchanger at a lower velocity. It is observed from the charging experiments that the decrease in the inlet air temperature has more influence in reducing the solidification time than the increase in the inlet air velocity. The heat exchanger designed in the present investigation is capable of maintaining the room temperature around 30°C for a longer duration of 8 hr when the heat load is 0.5 kW. It is suggested to design the modular heat exchanger with a surface area proportionate to the present heat exchanger size when the room heat load increases beyond 0.5 kW, in order to maintain a minimum comfortable temperature of 30°C in the room.  相似文献   

11.
In order to decrease the heat rejection pressure of heat pump using pure working fluid, CO2 or R744, other natural component including hydrocarbons (R290, R600a, R600, R1270, R170, R601) and dimethyl ether (RE170) is added to CO2, respectively, and then six binary mixtures are achieved. By environmental and thermodynamic comparisons, R290 is selected to be the most appropriate component candidate to mix with CO2, and meanwhile to weaken the flammability and explosivity for pure R290. Then, the system performances of heat pump using mixture of CO2 and R290 were experimentally studied when R290 is added to CO2 with a small fraction, and compared with that of the pure CO2. The experimental test rig is designed and set up for the transcritical heat pump system. When the refrigerant charge is variable, the heating coefficient performance, optimum heat rejection pressure, compressor power, mass flow rate of refrigerant, and total heat coefficient of gas cooler were researched. The variation ratios of heating coefficient performance and heating capacity with deviation from the optimum refrigerant charge were also investigated. The optimum refrigerant charge of CO2/R290 is obtained and the research results show that the addition of R290 to CO2 can efficiently reduce the heat rejection pressure and improve the system performance. The results in the present work could provide useful guidelines for the design and operation of heat pump system using CO2-based mixture.  相似文献   

12.
The heat-pipe solar water heating (HP-SWH) system and the heat-pipe photovoltaic/thermal (HP-PV/T) system are two practical solar systems, both of which use heat pipes to transfer heat. By selecting appropriate working fluid of the heat-pipes, these systems can be used in the cold region without being frozen. However, performances of these two solar systems are different because the HP-PV/T system can simultaneously provide electricity and heat, whereas the HP-SWH system provides heat only. In order to understand these two systems, this work presents a mathematical model for each system to study their one-day and annual performances. One-day simulation results showed that the HP-SWH system obtained more thermal energy and total energy than the HP-PV/T system while the HP-PV/T system achieved higher exergy efficiency than the HP-SWH system. Annual simulation results indicated that the HP-SWH system can heat the water to the available temperature (45°C) solely by solar energy for more than 121 days per year in typical climate regions of China, Hong Kong, Lhasa, and Beijing, while the HP-PV/T system can only work for not more than 102 days. The HP-PV/T system, however, can provide an additional electricity output of 73.019 kWh/m2, 129.472 kWh/m2, and 90.309 kWh/m2 per unit collector area in the three regions, respectively.  相似文献   

13.
Abstract

In this article, the convective heat transfer coefficients of various agricultural products were investigated under open sun drying conditions. Data obtained from open sun drying experiments for eight agricultural products, namely, mulberry, strawberry, apple, garlic, potato, pumpkin, eggplant, and onion were used to determine values of convective heat transfer coefficient. The value of convective heat transfer coefficient was determined as 1.861 W/m2°C for mulberry, 6.691 W/m2°C for strawberry, 11.323 W/m2°C for apple, 1.136 W/m2°C for garlic, 8.224 W/m2°C for potato, 8.613 W/m2°C for pumpkin, 6.981 W/m2°C for eggplant, and 6.767 W/m2°C for onion. The experimental error in terms of percent uncertainty was also calculated.  相似文献   

14.
The advanced zero emissions power plant (AZEP) project addresses the development of a novel “zero emissions,” gas turbine-based, power generation process to reduce local and global CO2 emissions in a cost-effective way.The key element in AZEP is an integrated MCM-reactor, in which (a) O2 is separated from air by means of a mixed-conducting membrane (MCM), (b) combustion of natural gas occurs in an N2-free environment and (c) the heat of combustion is transferred to air by heat exchange.This paper focuses on the development and testing of the ceramic components of the MCM-reactor (air separation membrane and heat exchangers). For compactness and manufacturability, a module design based on extruded square channel monoliths has been chosen. The manifold design enables gas distribution in a checkerboard pattern. Modules with contact area of >500 m2/m3 have been produced.Results from testing of the modules under close to realistic process conditions agree with model predictions. Extrapolation to AZEP process conditions gives an oxygen production rate of around 37 mol O2/(m3 s), or 15 MW/m3 power density (per net MCM volume). These values correspond to project targets and confirm the feasibility of the AZEP concept.  相似文献   

15.
This study analyzed the wintertime surface heat exchange for the Inner Mongolia reach of the Yellow River, China, based on the data from the nearby weather station at Wulateqianqi. In this analysis, the solar radiation is based on the observed data. Other components of the surface heat flux, that is, long‐wave radiation, and evaporative and conductive heat fluxes, are calculated. The relative importance of the contributions of long‐wave radiation, conductive, and evaporative heat fluxes are in descending order. The air temperature is the most important meteorological factor to the total heat flux. Although the wind speed influences evaporative and conductive heat fluxes, it has the least correlation with the total heat budget. The heat exchange coefficient for the linearized surface heat exchange equation is 21.87 W/(m2 °C), which is comparable with published values in the regions of United States and Canada with similar latitudes.  相似文献   

16.
In this communication, a new design of solar-energy-based water distillation cum drying unit with parabolic reflector has been designed, fabricated, and tested. Bitter gourd and potato slices are chosen as a drying commodity. Thermal performance of the developed system has been evaluated based on the experimental results and using linear regression analysis. Heat transfer coefficients (convective, evaporative, and radiative) for solar distillation system have been observed to be 2.48–4.09, 13.25–52.38, and 8.75–9.66 W/m2°C, respectively. Overall thermal efficiency and exergy efficiency for the distillation system has been found to be 18.77% and 1.2%, respectively. The convective heat transfer coefficient for potato slices are observed higher for initial hours and decreases as the day progresses. The average convective heat transfer coefficients for bitter gourd and potato slices have been observed as 2.18 and 5.04 W/m2°C, respectively. Experimental error in terms of percent uncertainty for bitter gourd and potato slices are found to be 42.93% and 37.06%, respectively. The present design of solar distillation and drying in a single unit could be beneficial for the development of remote, arid, and rural areas.  相似文献   

17.
为了满足新能源整车控制器试验参数测试的要求,本文设计了一种包括上位机、控制模块组、资源分配盒及相关设备的测试系统,详细说明了测试系统硬件平台设计和系统软件设计.测试结果表明,该系统具有可靠、灵活、智能化程度高和适用性强的特点.  相似文献   

18.
Large scale rainwater harvesting (LSRWH) is a promising alternative to address security and flood issues in urban areas. The development and planning of a LSRWH for an eco-community involves comprehensive site-planning, systems planning and design, which includes the rainwater source collection (roof) to the storage tank, the distribution and allocation system. This paper describes a new technique for designing a LSRWH for a community of 200 houses with an average of 4 persons per house and an average total daily water demand of 160 m3. It was found that the optimal size storage tank for a 20,000 m2 roof area is 160 m3 with a 60% reliability. The application of this model to the case study revealed a significant water saving up to 58% .The total cost for this system is 443,861 USD over a life-span of 25 years.  相似文献   

19.
By establishing wind tunnel and employing electrical heating method, the heat transfer characteristics of flat plate were investigated under environmental wind condition. Both the uniform and linear heat flux boundary conditions were adopted for comparison purpose. Besides, the impacts of heat flux qwm, tilt angle α and wind incidence angle θ on heat transfer were explored in cases of windward and leeward facing positions. The local convection heat transfer coefficient hcx and average convection Nusselt number Nucm were obtained. The results show that, when α is small, there are two maximum values of hcx under linear heat flux boundary condition. As for Nucm, differences between the two boundary conditions seem indistinctive. At windward orientation, Nucm is not sensitive to α. While for leeward orientation, Nucm has a rapid decline progress with the increasing α, which indicates the tilt angle α is an important parameter to affect the heat transfer of plate. Finally, new correlations of Nucm have been developed, which were proven effective in engineering applications.  相似文献   

20.
In this research, desert sand is used as the sensible heat storage medium, which exchanges heat with air in the downcomer to realize heat storage and heat release. The desert sand distribution uniformity has a significant impact on the heat exchange performance and efficiency between desert sand and air for the process of convection in the downcomer. Given the superiority of sensible heat storage in convective heat transfer between desert sand and air, distributors with cylinder or conical bore solid particles and homogeneity performance testing device are designed and manufactured on the basis of convection system equipped with solid particle–air downcomer. Then, the convection experiment between solid sand and air is researched. The greater the desert sand flow rate and higher the volume density, the larger the variance of regional mass flow rate and the worse the homogeneity performance. For the cylinder bore distributor, the smaller the sand particle size is, the greater affected the sand groups can be. The sand homogeneity performance is preferable with the two particle size ranges: 0.18-0.25 mm and 0.15-0.18 mm. The total sand flow rate decreases, but the uniformity improves with the increase of the air flow velocity, and the best distribution performance is achieved at an air velocity of 0.6 m/s. However, the distribution performance declines with the air flow velocity persistently increasing because the sand groups are pushed to one pipe side close to the wall. The sand groups deflect seriously with the air flow velocity increasing.  相似文献   