首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In a storm sewer system, the catch basin is the interface between surface runoff and the sewer. Responding to the need to improve the quality of stormwater from urban areas and transportation facilities, and spurred by Phase I and II Stormwater Rules from the U.S. Environmental Protection Agency, several companies market catch basin inserts as best management practices for urban water quality management. However, little data have been collected under controlled tests that indicate the pollutant removal efficiency of these inserts when the inflow is near what can be expected to occur in the field. A stormwater simulator was constructed to test inserts under controlled and replicable conditions. The inserts were tested for removal efficiency of total suspended solids (TSS) and total petroleum hydrocarbons (TPH) at an inflow rate of 757 to 814 L/min, with influent pollutant concentrations of 225 mg/L TSS and 30 mg/L TPH. These conditions are similar to stormwater runoff from small commercial sites in the southeastern United States. Results from the tests indicate that at the test flowrate and pollutant concentration, average TSS removal efficiencies ranged from 11 to 42% and, for TPH, the removal efficiency ranged from 10 to 19%.  相似文献   

2.
Urban stormwater runoff quality, widely investigated around the world, has been monitored less in Beijing, China, which impedes the municipal government to use best management practices to protect surface water. In this study, rainwater and stormwater runoff samples from roofs, roads, and a lawn on the campus of the Research Center for Eco-Environmental Sciences (RCEES) (Beijing, China) and from a ring road, with heavy traffic, have been sampled and analyzed for 31 storm events from June 2004 to August 2005. Total suspended solids (TSS), chemical oxygen demand (COD), 5-day biochemical oxygen demand (BOD5), total nitrogen, and total phosphorus concentrations in rainwater and runoff ranged over 2 or more orders of magnitude, meaning that the highest concentration of a certain pollutant did not always occur in a certain kind of runoff. Runoff contained significantly higher concentrations of pollutants than rainwater. On the campus of RCEES, TSS and total phosphorus in runoff samples from the lawn and roads were significantly higher than those from roofs, while the COD, BOD5, and total nitrogen concentrations were not significantly different in runoff among surfaces. Compared with runoff from the roads on campus, runoff from the ring road contained more COD and total nitrogen, but less TSS, BOD5, and total phosphorus. All pollutants measured in runoff from roofs on campus and from the ring road showed a peak concentration in starting runoff, which then decreased sharply. The peak concentrations of COD, BOD5, total nitrogen, and total phosphorus in the roof runoff increased with the increase in time of the antecedent dry period. Thus, urban stormwater pollution control, especially for first-flush control, is of great importance for the full use of rainwater and prevention of water pollution.  相似文献   

3.
A novel nanosize metallic calcium/iron dispersed reagent was synthesized and tested as coagulant/catalyst in a hybrid zero valent iron (ZVI)/H2O2 oxidation process to treat leachate. Two different types of leachates, one from municipal solid waste (MSW) tipping hall (MSWIL) and second from an MSW landfill site (MSWLL), were collected and characterized. The morphology, elemental composition, and mineral phases of the nano-Ca/CaO and nano-Fe/Ca/CaO were characterized by scanning electron microscopy–electron dispersive spectroscopy (SEM-EDS) and x-ray powder diffraction (XRD) analysis. The coagulation process with 2.5 g L?1 nano-Ca/CaO attained 64.0, 56.0, and 20.7% removal of color, chemical oxygen demand (COD), and total suspended solids (TSS) in MSWLL. With only 1.0 g L?1 of nano-Fe/Ca/CaO, relatively high color, COD and TSS removal was achieved in MSWLL at 67.5, 60.2, and 37.7%, respectively. The heavy metal removal efficiency reached 91–99% after treatment with nano-Fe/Ca/CaO in both leachate samples. The coupling process, using 1.0 g L?1 of nano-Fe/Ca/CaO and 20 mM H2O2 doses, achieved enhancement removal of color, COD, and TSS, up to 95%, 96%, and 66%, respectively, without initial pH control. After this treatment, the color, COD, TSS, and heavy metals were significantly decreased, fitting the Korean discharge regulation limit. A hybrid coupled zero valent iron (ZVI)/H2O2 oxidation process with novel nanosized metallic calcium/iron dispersed reagent proved to be a suitable treatment for dealing with leachate samples.

Implications: Conventional treatments (biological or physicochemical) are not sufficient anymore to reach the level of purification needed to fully reduce the negative impact of landfill leachates on the environment. This implies that new treatment alternatives species must be proposed. A coupled zero valent iron (ZVI)/H2O2 oxidation process proved to be a suitable treatment for dealing with leachate samples. Coagulation with nFe/Ca/CaO allows 91–99% of heavy metals removal. The coupled coagulation–oxidation process by nFe/Ca/CaO reveals excellent ability to treat leachate. After coupled treatment the color, COD, and TSS were also much lower than the discharge regulation limit.  相似文献   

4.
The scarcity of water resources in Egypt has necessitated the use of various types of lower quality water. Agricultural drainage water is considered a strategic reserve for meeting increasing freshwater demands. In this study, a novel model series was applied to a drainage basin in the Nile Delta to optimize integrated water quality management for agriculture and the aquatic environment. The proposed model series includes a waste load allocation model, an export coefficient model, a stream water quality model, and a genetic algorithm. This model series offers an optimized solution for determining the required removal levels of total suspended solids (TSS), the chemical oxygen demand (COD) at point and non-point pollution sources, and the source flows that require treatment to meet a given water quality target. The model series was applied during the summer and winter to the El-Qalaa basin in the western delta of the Nile River. Increased pollutant removal and treated fractions at point and non-point sources reduced violations of the TSS standards from 732.6 to 238.9 mg/L in summer and from 543.1 to 380.9 mg/L in winter. Likewise, violations of the COD standards decreased from 112.4 mg/L to 0 (no violations) in summer and from 91.7 mg/L to no violations in winter. Thus, this model is recommended as a decision support tool for determining a desirable waste load allocation solution from a trade-off curve considering costs and the degree of compliance with water quality standards.  相似文献   

5.

This study aimed at analysing the performance of horizontal subsurface flow constructed wetlands (CWs) to treat combined sewer overflow (CSO). Four horizontal subsurface flow CWs, organized in two groups (A and B) each with a planted (Phragmites australis) and a non-planted bed, were loaded with simulated CSO, with group B receiving twice the hydraulic load of group A. Beds were monitored for pH, dissolved oxygen, conductivity, redox potential, chemical oxygen demand (COD), total suspended solids (TSS) and enterococci. Porosity variations were also estimated. Monitoring was conducted during spring and wintertime, with regular and irregular loading frequencies. Results showed an average treatment efficiency of 90–100 % for TSS, 60–90 % for COD and 2–6 log for enterococci. Removal rates were especially relevant in the first 24 h for COD and TSS. TSS and enterococci removal did not exhibit the influence of macrophytes or the applied hydraulic load while COD’s removal efficiency was lower in the higher load group and in planted beds.

  相似文献   

6.
The effect of an oxidative pre-treatment with ozone on the removal of Pharmaceutical and Personal Care Products (PPCPs) during the anaerobic digestion of sewage sludge has been investigated. Besides, the digested sludge characteristics in terms of pathogens content, dewatering properties, heavy metals content and linear alkylbenzene sulfonates (LAS) were determined. During ozonation (20mg O(3)/g TSS), about 8% of volatile solids (VS) and 60% of the chemical oxygen demand (COD) were solubilized. However, no mineralization was observed. The elimination of VS and total COD during anaerobic digestion were not affected by ozone treatment with efficiencies ranging from 60% to 65%. All PPCPs considered were removed during anaerobic treatment of sludge, with efficiencies ranging from 20% to 99%. No significant influence of ozone pre-treatment was observed on PPCPs elimination except for carbamazepine. Pathogens, heavy metals and LAS contents after conventional and pre-ozonation treatment of sewage sludge were below the legal requirements. However, the dewatering properties of sludge were deteriorated when the ozone pre-treatment was applied.  相似文献   

7.
Attempts were made in this study to examine the effectiveness of sequencing batch reactor (SBR) for the treatment of beverage industrial wastewater. The SBR was operated at three different organic loading rates (OLRs): 2, 1.7 and 1.1 kg COD/m3 d. Results of continuous long-term operation showed that by decreasing OLR from 2 to 1.7 kg COD/m3 day, the removal efficiency was increased from 95.5 to 99.3% for COD, from 95.3 to 98.1% for BOD and from 87 to 97.7% for TSS. While further decreasing of the OLR to 1.1 kg COD/m3 day, there is no significant adverse effect on organics removal. Also, residual total nitrogen (TN) concentration decreased by decreasing the OLR. However, increasing the OLRs exerted a slightly negative effect on the removal of total phosphorous. On the other hand, the experimental data indicated that the substrate utilization kinetic followed Monod's kinetics model approximately. The maximum specific substrate utilization rate (micro(max), half velocity coefficient (Ks), growth yield coefficient (Y) and decay coefficient (Kd) were 2.94 d(-1), 15.22 mg/L, 0.2384 g VSS/g COD and 0.2019 h(-1), respectively.  相似文献   

8.
An upflow anaerobic sludge blanket (UASB)-anoxicaerobic system was used for treatment of tomato and bean processing wastewater. At various hydraulic retention times, ranging from 0.7 to 5 days, excellent removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total suspended solids (TSS), ammonia-nitrogen (NH4-N), and total Kjeldahl nitrogen was achieved with final effluent BOD/TSS/NH4N concentrations of less than 15/15/1 mg/L. Biogas yield in the UASB reactor varied from 0.33 to 0.44 m3/kgCODremoved. The kinetics of anaerobic treatment were investigated. The yield coefficient was 0.03 gVSS/gCOD; maximum specific growth rate was 0.24 day(-1); Monod half velocity constant was 135 mgCOD/L; and specific substrate utilization rate was 3.25 gCOD/gVSS x d. Nitrification and denitrification kinetics were studied in batch experiments, and the rates were comparable with those in the continuous flow system.  相似文献   

9.
电混凝处理电镀综合废水   总被引:4,自引:0,他引:4  
采用电混凝法处理酸性电镀综合废水,首先研究了不同电流密度对总氰化物、重金属和化学需氧量(COD)去除率的影响。实验结果表明,电混凝可有效去除酸性电镀综合废水中的氰化物与重金属。随着电流密度的增大,总氰化物与重金属的去除率逐渐提高。当电流密度为10mA/cm2时,废水中残留的总氰化物、Cu2+、Ni2+、Cr6+和Zn2+ 的浓度分别为23.0、25.0、4.5、0.2和0.2mg/L。为了进一步提高去除率,在电化学体系中添加H2O2,随着H2O2投量的增大,总氰化物、重金属、COD去除率不断提高。当H2O2投量为3mL/L时,处理过废水中残留总氰化物、Cu2+、Ni2+、Cr6+、Zn2+和COD的浓度分别为0.2、2.0、3.0、1.5、0.1和220mg/L。  相似文献   

10.
INTRODUCTION: Environmental safe and friendly management and disposal of wastewater sludge is a problem of every treatment plant throughout the world. Bioseparation and dewaterability of raw domestic wastewater sludge were evaluated for proper management and disposal by mycoremediation, i.e., using prior grown 2% (v/v) spore suspension of filamentous fungal (Mucor hiemalis Wehmer) broth inoculation, which were grown in 2% (w/v) solution of malt extract and wheat flour for 48-60 h in orbital shaker. DISCUSSION: Within 2-3 days of treatment application, encouraging results were achieved in total dry solids (TDS), total suspended solid (TSS), turbidity, chemical oxygen demand (COD), specific resistance to filtration (SRF), and pH due to fungal treatment in recognition of bioseparation and dewaterability of wastewater sludge compared to control. The significant reduction of TDS was remarked at fungal biomass (FB) in wheat flour (WF) treatment. The removal of TSS, turbidity, COD, and SRF were observed 96.0%, 99.4%, 92.6%, and 97.6%, respectively, in supernatant at 5 days by FB in WF. The SRF measuring the dewaterability was decreased with maximum (0.26 × 10(-12) mg/kg) equivalent to 95.5% at 2 days in FB in WF also. FB in WF broth is a potential, environmental friendly, comparatively low-cost biological technique which might play the significant role for bioremediation and bioseparation of domestic wastewater sludge. The present technique may bring a dynamic change in treatment of wastewater in future.  相似文献   

11.
A load model based on antecedent dry periods for pollutants in stormwater.   总被引:2,自引:0,他引:2  
A load model for stormwater constituents is proposed that describes mass retained on the drainage area after previous storms, as a function of a weighted sum of previous antecedent dry periods. It was used to compute the event load for 14 constituents--zinc, copper, cadmium, nickel, chromium, lead, mercury, silver, total suspended solids (TSS), E. coli, fecal coliform, total soluble phosphorus, total phosphorus, and 5-day biochemical oxygen demand. The results show acceptable fits for most constituents based on over 400 rain events (2000 to 2004) in Milwaukee, Wisconsin. Considering the retained pollutant mass after one previous storm rather than assuming the area to be clean after the previous storm gives more accurate results for all constituents, except TSS and silver. The model can be used for mixed land-use areas. The ratios of deposition fluxes of zinc and individual metals were determined at a major parking lot producing a profile characteristic of automobile emissions.  相似文献   

12.
A two-stage membrane bioreactor was used to treat dissolved-air-flotation pretreated, high-strength pet food wastewater characterized by oil and grease concentrations of 50 000 to 82 000 mg/L and total chemical oxygen demand (COD) and five-day biochemical oxygen demand (BOD5) concentrations of 100 000 and 80 000 mg/L, respectively, to meet stringent surface discharge criteria (i.e., BOD5, total suspended solids [TSS], and ammonium-nitrogen [NH4(+)-N] of < 10 mg/L at an overall hydraulic retention time of 6.3 days). Organic contaminants were removed primarily in the first stage, followed by almost complete removal of ammonia in the second stage. Despite a rise in poorly biodegradable COD in the second stage, overall removal of TSS, BOD5, COD, and ammonia was 100, 99.9, 95.2, and 99.7%, respectively, thus readily achieving the required criteria. Consistent nitrite accumulation over a period of more than 100 days, even at dissolved oxygen concentrations of more than 2.5 mg/L, was remarkable. A residual alkalinity requirement for nitrification was quantified. Membrane performance was extensively studied in this work.  相似文献   

13.
The capacity to reach lower bounds for extraction of pollutants from wastewater by four floating aquatic macrophytes--water hyacinth (Eichhornia crassipes), water lettuce (Pistia stratiotes), salvinia (Salvinia rotundifolia), and water primroses (Ludvigia palustris)--is investigated. It is shown that the following lower bounds can be established for wastewater purification with water hyacinth: biochemical oxygen demand (BOD), 1.3 mg/L; chemical oxygen demand (COD), 11.3 mg/L; total suspended solids (TSS), 0.5 mg/L; turbidity, 0.7 NTU; ammonia, 0.2 mg/L; and phosphorus, 1.4 mg/L. Also, the following lower bounds can be established for wastewater purification with water lettuce: BOD, 1.8 mg/L; COD, 12.5 mg/L; TSS, 0.5 mg/L; turbidity, 0.9 NTU; ammonia, 0.2 mg/L; and phosphorus, 1.6 mg/L. These lower bounds were reached in 11- to 17-day experiments that were performed on diluted wastewater with reduced initial contents of the tested water quality indicators. As expected, water hyacinth exhibited the highest rates and levels of pollutant removal, thereby producing the best lower bounds of the water quality indicators. Given the initially low levels, BOD was further reduced by 86.3%, COD by 66.6%, ammonia by 97.8%, and phosphorus by 65.0% after 11 days of a batch experiment. The capacity of water plants to purify dilute wastewater streams opens new options for their application in the water treatment industry.  相似文献   

14.
Two free water surface (FWS) and two subsurface flow (SSF) pilot-size constructed wetlands treating highway runoff (HRO) were monitored over a period of two years (September 2005-August 2007). One FWS and one SSF were designed with a hydraulic retention time (HRT) of 12h, named FWS12 and SSF12, respectively, with each one capable of treating a maximum HRO of 12.6 m(3) d(-1). The other couple, named FWS24 and SSF24, respectively, was designed with an HRT of 24h, with each receiving a maximum HRO of 6.3 m(3) d(-1). The influent flowed from a highway section with a total surface 2752 m(2) on the island of Crete, Greece, in the heart of the South-Central Mediterranean region. Influent and effluent were monitored for COD, TSS, total N (TN), NO(3)(-) and total P (TP) concentrations. Furthermore, removal efficiencies were examined for heavy metals (Cu, Ni, Pb, Zn) for both years, while polycyclic aromatic compounds (PAHs) were examined for the period between September 2006 and August 2007. The influent had a two-year average COD value of 101 mg l(-1), whereas the mean values for TSS, TN, N-NO(3)(-) and TP were 203, 4.30, 1.25 and 4.17 mg l(-1), respectively. For Cu, Ni, Pb and Zn the respective two-year mean influent concentrations were 56, 114, 49 and 250 microg l(-1). Mean concentration of total PAHs in runoff (summation operator PAHs, 16 compounds) were 12.01 microg l(-1). The performance among the four beds was not significantly different according to ANOVA analysis followed by Tukey test (at p<0.05) for almost all the above physicochemical parameters, suggesting that all systems performed in a similar way. All studied systems, achieved a mean of two-year removal efficiencies of 47% for COD, 89% for TSS, 49% for TN, 58% for N-NO(3)(-), 60% for TP, 47% for Cu, 23% for Ni, 33% for Pb, 61% for Zn and 59% for summation operator PAHs (16 compounds).  相似文献   

15.
This paper investigated the highway stormwater quality at two Texas cities-Austin and College Station. Two highways with high average daily traffic were monitored using passive stormwater samplers for collecting first-flush runoff during a 16-month period. Detailed traffic and weather data were collected at College Station sites, but only weather data were obtained at Austin sites. A stepwise regression analysis on College Station data identifies the antecedent dry period (ADP) as the most significant predictor of pollutant concentration. Specifically, the College Station data show an unexpected result that pollutant event mean concentrations significantly decrease with increasing ADP for all analyzed pollutants. However, the runoff concentrations observed in Austin were not significantly correlated with ADP. The result from College Station data provides a different insight to the pollutant buildup and removal process on highways. Conceptual highway pollutant buildup and removal models are proposed for generating further discussion and research interest.  相似文献   

16.
Accumulated sediments in a 32,000-m3 detention basin linked to a separate stormwater system were characterized in order to infer their health hazards. A sampling scheme of 15 points was defined according to the hydrological behaviour of the basin. Physical parameters (particle size and volatile organic matter content) were in the range of those previously reported for stormwater sediments. Chemical analyses on hydrocarbons, PAHs, PCBs and heavy metals showed high pollutant concentrations. Microbiological analyses of these points highlighted the presence of faecal indicator bacteria (Escherichia coli and intestinal enterococci) and actinomycetes of the genus Nocardia. These are indicative of the presence of human pathogens. E. coli and enterococcal numbers in the sediments were higher at the proximity of the low-flow gutter receiving waters from the catchment. These bacteria appeared to persist over time among urban sediments. Samples highly contaminated by hydrocarbons were also shown to be heavily contaminated by these bacteria. These results demonstrated for the first time the presence of Nocardial actinomycetes in such an urban context with concentrations as high as 11,400 cfu g?1.  相似文献   

17.
Improved solubilization of activated sludge by ozonation in pressure cycles   总被引:1,自引:0,他引:1  
Cheng CJ  Hong PK  Lin CF 《Chemosphere》2012,87(6):637-643
The generation of a large volume of activated sludge (AS) from wastewater treatment has increasingly become a great burden on the environment. Anaerobic digestion is routinely practiced for excess waste sludge; however, the process retention time is long because of kinetic limitation in the hydrolysis step. We tested the feasibility of applying ozone in pressure cycles to enhance the disintegration and solubilization of AS with the goal to prepare them for digestion using reduced ozone dose and contact time. The AS was subjected to repetitive pressure cycles in a closed vessel in which an ozone gas mixture was compressed into the slurry to reach 1040 kPa in the headspace to be followed by rapid venting. For a returned AS with total COD (tCOD) of 8200 mg L(-1), a dose of 0.01 gO(3)g(-1) total suspended solids (TSS) delivered via 20 pressure cycles within 16 min resulted in a 37-fold increase of the sCOD/tCOD ratio (due to increased soluble COD, i.e. sCOD) and a 25% reduction of TSS, in comparison to a dose of 0.08 gO(3)g(-1) TSS via bubbling contact over 15 min that resulted in a 15-fold increase of the sCOD/tCOD ratio and a 12% reduction of TSS. Sludge solubilization was evidenced by increased dissolved contents of total phosphorous (from 10 to 64 mg L(-1)), total nitrogen (from 14 to 120 mg L(-1)), and protein (from <15 to 39 mg L(-1)) in the sludge suspension after treatment, indicating significant solubilization of AS.  相似文献   

18.
采用臭氧氧化污泥减量法对畜禽养殖废水SBR中的剩余污泥进行处理。当臭氧反应时间控制在30 min时,污泥的溶解比例在30%左右(以 MLSS计)。上清液中一定量的SCOD溶出可为生物处理单元提供充足的碳源,同时在上清液中,TN、TP及水相重金属浓度增加有限,臭氧氧化后的污泥液回流污水处理系统后造成的N、P处理负荷较小,重金属对污泥微生物的活性抑制风险较低。若继续延长臭氧的反应时间,上清液SCOD、TN、TP以及重金属Cu、Pb的释放速率明显增加,同时上清液的C/N降低,臭氧化后的污泥液回流反而不利于生物单元的脱氮处理。综合考虑TN、TP及水相重金属浓度增加的危害性,臭氧反应时间应控制在30 min,臭氧实际投加量应为123.1 mg O3/g SS。  相似文献   

19.
Copper, a priority substance on the EU-Water Framework Directive list, is widely used to protect grapevines against fungus diseases. Many vineyards being located on steep slopes, large amounts of Cu could be discharged in downstream systems by runoff water. The efficiency of stormwater detention basins to retain copper in a vineyard catchment was estimated. Suspended solids, dissolved (Cudiss) and total Cu (Cutot) concentrations were monitored in runoff water, upstream, into and downstream from a detention pond. Mean Cutot concentrations in entering water was 53.6 μg/L whereas it never exceeded 2.4 μg/L in seepage. Cutot concentrations in basin water (>100 μg/L in 24% of the samples) exceeded LC50 values for several aquatic animals. Copper was principally sequestered by reduced compounds in the basin sediments (2/3 of Cutot). Metal sequestration was reversible since sediment resuspension resulted in Cu remobilization. Wind velocity controlled resuspension, explained 70% of Cudiss variability and could help predicting Cu mobilization.  相似文献   

20.
Sedimentation is a common but complex phenomenon in the urban drainage system. The settling mechanisms involved in detention basins are still not well understood. The lack of knowledge on sediment transport and settling processes in actual detention basins is still an obstacle to the optimization of the design and the management of the stormwater detention basins. In order to well understand the sedimentation processes, in this paper, a new boundary condition as an attempt to represent the sedimentation processes based on particle tracking approach is presented. The proposed boundary condition is based on the assumption that the flow turbulent kinetic energy near the bottom plays an important role on the sedimentation processes. The simulated results show that the proposed boundary condition appears as a potential capability to identify the preferential sediment zones and to predict the trapping efficiency of the basin during storm events.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号