首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
Reducing airborne microorganisms may potentially improve the environment in layer breeding houses. The effectiveness of slightly acidic electrolyzed water (SAEW; pH 5.29–6.30) in reducing airborne microorganisms was investigated in a commercial layer house in northern China. The building had a tunnel-ventilation system, with an evaporative cooling. The experimental area was divided into five zones along the length of the house, with zone 1 nearest to an evaporative cooling pad and zone 5 nearest to the fans. The air temperature, relative humidity, dust concentration, and microbial population were measured at the sampling points in the five zones during the study period. The SAEW was sprayed by workers in the whole house. A six-stage air microbial sampler was used to measure airborne microbial population. Results showed that the population of airborne bacteria and fungi were sharply reduced by 0.71 × 105 and 2.82 × 103 colony-forming units (CFU) m?3 after 30 min exposure to SAEW, respectively. Compared with the benzalkonium chloride (BC) solution and povidone-iodine (PVP-I) solution treatments, the population reductions of airborne fungi treated by SAEW were significantly (P < 0.05) more, even though the three disinfectants can decrease both the airborne bacteria and fungi significantly (P < 0.05) 30 min after spraying.
Implications: There are no effective methods for reducing airborne microbial levels in tunnel-ventilated layer breeding houses; additionally, there is limited information available on airborne microorganism distribution. This research investigated the spatial distribution of microbial population, and the effectiveness of spraying slightly acidic electrolyzed water in reducing microbial levels. The research revealed that slightly acidic electrolyzed water spray was a potential method for reducing microbial presence in layer houses. The knowledge gained in this research about the microbial population variations in the building may assist producers in managing the bird housing environment and engineers in designing poultry houses.  相似文献   

2.
Reducing airborne dust is an essential process for improving hen housing environment. Dust reduction effects of neutral electrolyzed water (pH 8.2) spray were investigated in a commercial tunnel-ventilated layer breeding house during production in northern China. A multipoint sampler was used to measure airborne dust concentration to study the dust reduction effects and distribution in the house. Compared with the control treatment (without spray), airborne dust level was reduced 34% in the 3 hr after spraying 216 mL m?2 neutral electrolyzed water in the breeding house. The dust concentration was significantly higher during the periods of feed distribution (1.13 ± 0.13 mg m?3) and artificial insemination (0.72 ± 0.13 mg m?3) compared with after spray (0.47 ± 0.09 mg m?3) and during lights-off period (0.29 ± 0.08 mg m?3) in the three consecutive testing days (P < 0.05). The experimental cage area was divided into four zones along the length of the house, with zone 1 nearest to the evaporative cooling pad and zone 4 nearest to the fans. The air temperature, relative humidity, airflow rate, and dust concentration were measured at the sampling points of the four zones in 3 consecutive days and mortality of the birds for the duration of a month were investigated. The results showed that the air temperature, airflow rate, dust concentration, and number of dead birds increase from zone 1 to zone 4 in the tunnel-ventilated layer breeding house.

Implications: It is difficult to effectively reduce hen house airborne dust levels and limited information is available on airborne dust distribution in tunnel-ventilated hen houses. This work investigates (i) the application of neutral electrolyzed water spray for reducing dust in a layer breeding houses; (ii) dust concentration variations in 24-hr house operation; as well as (iii) the effects of location on dust concentrations. It was demonstrated that neutral electrolyzed water spray can be efficiently used for dust reduction in poultry houses. Further, a better understanding of the dust concentration variations in 24-hr house operation and in different spatial zones can contribute to bird housing environment management and poultry house design so as to improve bird health.  相似文献   

3.
Airborne microorganisms, especially the pathogenic microorganisms, emitted from animal feeding operations (AFOs) may harm the environment and public health and threaten the biosecurity of the farm and surrounding environment. Electrolyzed water (EW), which was considered to be an environmentally friendly disinfectant, may be a potential spraying medium of wet scrubber for airborne microorganism emission reduction. A laboratory test was conducted to investigate the airborne bacteria (CB) removal efficiency of the wet scrubber by EW spray with different designs and operating parameters. Both the available choline (AC) initial loss rate and AC traveling loss rate of acidic electrolyzed water (AEW; pH = 1.35) were much higher than those of slightly acidic electrolyzed water (SAEW; pH = 5.50). Using one spraying stage with 4 m sec?1 air speed in the duct, the no detect lines (NDLs) of SAEW (pH = 5.50) for airborne Escherichia coli, Staphylococcus aureus, and Salmonella enteritidis removal were all 50 mg L?1, whereas the NDLs of AEW (pH = 1.35) for airborne E. coli, S. aureus, and S. enteritidis removal increased to 70, 90, and 90 mg L?1, respectively. The NDLs of SAEW (pH = 5.50) for airborne E. coli, S. aureus, and S. enteritidis were lower than those of AEW (pH = 1.35) at single spraying stage. Increase in the number of stages lowered the NDLs of both SAEW (pH = 5.50) and AEW (pH = 1.35) for airborne E. coli, S. aureus, and S. enteritidis. EW with a higher available chlorine concentration (ACC) was needed at air speed of 6 m sec?1 to reach the same airborne CB removal efficiency as that at air speed of 4 m sec?1. The results of this study demonstrated that EW spray wet scrubbers could be a very effective and feasible airborne CB mitigation technology for AFOs.

Implications: It is difficult to effectively reduce airborne bacteria emitted from animal feeding operations (AFOs). Electrolyzed water (EW) with disinfection effect and acidity is a potential absorbent for spray in wet scrubber to remove microorganisms and ammonia. Based on the field test results, a laboratory experiment we conducted this time was to optimize the design and operation parameters to improve the airborne bacteria removal efficiency. A better understanding of the EW application in the wet scrubber can contribute to the mitigation of airborne bacteria from animal houses and improve the atmosphere air quality.  相似文献   


4.
The main objective of this study is to apply neutral electrolyzed water (NEW) spraying to inactivate bioaerosols. We evaluated the inactivation efficiency of NEW applied to inactivate two airborne bacterial Escherichia coli and Bacillus subtilis aerosols inside an environmental-controlled chamber in the study. Generated with electrolyzing 6.15 M sodium chloride brine, the NEW with free available chlorine (FAC) concentration 50, 100, and 200 ppm was pumped with an air pressure of 70 kg/cm2 through nozzle into the chamber to inactive E. coli and B. subtilis aerosols precontaminated air (initial counts of 3?×?104 colony-forming units [CFU]/m3). Bacterial aerosols were collected and cultured from chamber before and after NEW spray. The air exchange rate (ACH, hr?1) of the chamber was set to simulate fresh air ventilating dilution of indoor environment. First-order concentration decaying coefficients (Ka, min?1) of both bacterial aerosols were measured as an index of NEW inactivation efficiency. The result shows that higher FAC concentration of NEW spray caused better inactivation efficiency. The Ka values under ACH 1.0 hr?1 were 0.537 and 0.598 for E. coli of FAC 50 and 100 ppm spraying, respectively. The Ka values of FAC 100 ppm and 200 ppm spraying for B. subtilis were 0.063 and 0.085 under ACH 1.0 hr?1, respectively. The results indicated that NEW spray is likely to be effective in inactivation of bacterial airborne contamination. Moreover, it is observed in the study that the increase of ventilation rate and the use of a larger orifice-size nozzle may facilitate the inactivation efficiency.

Implications: Bacterial aerosols have been implicated in deterioration of air quality and occupational health. Effective, safe, and economic control technology is highly demanded, especially for agricultural and food industries. In the study, NEW mist spraying performed effectively in controlling E. coli and B. subtilis modeling bioaerosols contamination. The NEW revealed its potential as an alternative airborne disinfectant worth being discovered for improving the environmental quality in the future.  相似文献   

5.
In this study, m-xylene biodegradation was examined in bacteria-water mixed solution and biotrickling filter (BTF) systems amended with the nonionic surfactant Tween 80. The mixed bacteria were obtained from the activated sludge of a coking plant through a multisubstrate acclimatization process. High-throughput sequencing analysis revealed that Rhodanobacter sp. was the dominant species among the mixed bacteria. In the bacteria-water mixed solution, the bacterial density increased with increasing Tween 80 concentration. Hence, Tween 80 could be utilized as substrate by the mixed bacteria. Tween 80, with concentrations of 50–100 mg L?1, could enhance the bioavailability of m-xylene and consequently improve the degradation efficiency of m-xylene. However, further increasing the initial concentration of Tween 80 would decrease the degradation efficiency of m-xylene. At concentrations exceeding 100 mg L?1, Tween 80 was preferentially degraded by the mixed bacteria over m-xylene. In BTF systems, when the m-xylene inlet concentration was 1200 mg m?3 and the empty bed residence time was 20 sec, the removal efficiency and elimination capacity of BTF1 with Tween 80 addition were at most 20% and 24% higher than those of BTF2 without Tween 80 addition. Overall, the integrated application of the mixed bacteria and surfactant was demonstrated to be a highly effective strategy for m-xylene waste gas treatment.

Implications: The integrated application of mixed bacteria and surfactant was demonstrated to be a promising approach for the highly efficient removal of m-xylene. Surfactant can activate mixed bacteria to degrade m-xylene by increasing its bioavailability. Besides, surfactant can be utilized as carbon source by the mixed bacteria so that the growth of mixed bacteria can be promoted. It is expected that the integrated application of both technologies will become more common in future chemical industry.  相似文献   

6.
In this study, the effects of tetracycline exposure on wheat growth and the microbial community structure in the rhizosphere were investigated under hydroponic culture conditions. Exposure to various concentrations of tetracycline resulted in significant suppression of the growth of wheat roots and shoots, with minimum doses of 0.8 mg L?1 and 4 mg L?1 resulting in inhibition rates of 32% and 15.4%, respectively. Complete inhibition of the growth of these two parts of wheat plants was observed in response to treatment with tetracycline at 20 mg L?1 and 100 mg L?1, respectively. However, the germination of wheat seeds was not sensitive to exposure to tetracycline. The effects of tetracycline exposure on the microbial community in the wheat rhizosphere were evaluated through traditional cultivation and molecular biological analyses. The cultivation results indicated that bacteria were the dominant population, being present in concentrations of 1× 108–2.45× 109CFUs mL?1, although 39% to 87% inhibition occurred in response to tetracycline. The concentration of fungi increased in all tetracycline treated samples to 2.5 to 15.8 times that of the control. The highest concentration of fungi (4.27× 108 CFU mL?1) was observed in response to 60 mg L?1 tetracycline after 15 days of cultivation. In this stage, a large amount of fungal colonies was observed on the surface of the culture solution, the wheat roots became rotted and the plants became atrophic or even died. Molecular biological analysis indicated that the bacterial community structure was significantly different in samples that were exposed to high levels of tetracycline (over 20 mg L?1) than in samples that were exposed to lower concentrations. As the concentration of tetracycline increased, the diversity of the bacteria decreased. Additionally, several dominant sensitive species such as Sphingobacterium multivorum were suppressed by tetracycline, while some resistant species such as Acinetobacter sp. appeared or were conserved. The bacteria population tended to stabilize when the drug concentration exceeded 40 mg L?1.  相似文献   

7.

The novel SARS-CoV-2 outbreak was declared as pandemic by the World Health Organization (WHO) on March 11, 2020. Understanding the airborne route of SARS-CoV-2 transmission is essential for infection prevention and control. In this study, a total of 107 indoor air samples (45 SARS-CoV-2, 62 bacteria, and fungi) were collected from different wards of the Hajar Hospital in Shahrekord, Iran. Simultaneously, bacterial and fungal samples were also collected from the ambient air of hospital yard. Overall, 6 positive air samples were detected in the infectious 1 and infectious 2 wards, intensive care unit (ICU), computed tomography (CT) scan, respiratory patients’ clinic, and personal protective equipment (PPE) room. Also, airborne bacteria and fungi were simultaneously detected in the various wards of the hospital with concentrations ranging from 14 to 106 CFU m?3 and 18 to 141 CFU m?3, respectively. The highest mean concentrations of bacteria and fungi were observed in respiratory patients’ clinics and ICU wards, respectively. Significant correlation (p < 0.05) was found between airborne bacterial concentration and the presence of SARS-CoV-2, while no significant correlation was found between fungi concentration and the virus presence. This study provided an additional evidence about the presence of SARS-CoV-2 in the indoor air of a hospital that admitted COVID-19 patients. Moreover, it was revealed that the monitoring of microbial quality of indoor air in such hospitals is very important, especially during the COVID-19 pandemic, for controlling the nosocomial infections.

  相似文献   

8.
High microbial concentrations and emissions associated with livestock houses raise health and environmental concerns. A pilot-scale ultraviolet photocatalytic oxidation (UV-PCO) scrubber was tested for its efficacy to inactivate aerosolized Enterococcus faecalis and infectious bursal disease virus (IBDV). Microbial reduction was determined by the difference in microbial concentrations measured in the upstream and downstream isolators that were connected to the two ends of the UV-PCO scrubber. Two UV irradiance levels were tested by using one or two UV lamps. The theoretical average UV irradiances were 6,595 µ W cm?2 with one UV lamp and 12,799 µ W cm?2 with two UV lamps. At the tested ventilation rate (70 m3 hr?1), the contact time was 1 sec. Reduction rate and other two indexes (k-value and Z-value) that normalized UV radiation were calculated to describe the extent of microbial inactivation. The UV-PCO scrubber eliminated >99.7% of airborne E. faecalis from the incoming airstream under one UV lamp irradiance, and the reduction was further increased by 0.2–0.3% when the second UV lamp was added. The reduction rate for airborne IBDV was 72.4% with one UV lamp. The calculated k-values were 0.501–0.594 cm2 mJ?1 for airborne E. faecalis and 0.217 cm2 mJ?1 for IBDV. The Z-value of airborne E. faecalis to UV irradiance was 9.3 (±1.6)?×?10?4 cm2 µ W?1 sec?1. The results indicate that a UV-PCO scrubber can serve as an effective and efficient technology for inactivating airborne bacteria and virus. Scaling up of the pilot-scale scrubber for field use will require considerations such as design air treatment capacity, UV irradiance level, contact time, dust concentration, susceptibility of target microorganisms, and expected reduction rate.

Implications: This work demonstrated that a UV-PCO scrubber can be used to inactivate animal-associated airborne microorganisms, thus reducing microbial emissions from livestock houses and minimizing the biological impact to ambient environment. The microbial reduction efficiency by the UV-PCO scrubber varied depended on the level of UV irradiation and the target microbial species. The tested viral species (infectious bursal disease virus) was more resistant to the UV-PCO scrubber as compared to its counterpart bacterial species (E. faecalis).  相似文献   

9.
The effect of elapsed time between spraying and first leaching event on the leaching behavior of five herbicides (terbuthylazine, S-metolachlor, mesotrione, flufenacet, and isoxaflutole) and two metabolites (desethyl-terbuthylazine and diketonitrile) was evaluated in a 2011–2012 study in northwest Italy. A battery of 12 lysimeters (8.4 m2 long with a depth of 1.8 m) were used in the study, each filled with silty-loam soil and treated during pre-emergence with the selected herbicides by applying a mixture of commercial products Lumax (4 L ha?1) and Merlin Gold (1 L ha?1). During treatment periods, no gravity water was present in lysimeters. Irrigation events capable of producing leaching (40 mm) were conducted on independent groups of three lysimeters on 1 day after treatment (1 DAT), 7 DAT, 14 DAT, and 28 DAT. The series was then repeated 14 days later. Leachate samples were collected a few days after irrigation; compounds were extracted by solid phase extraction and analyzed by high-performance liquid chromatography and gas chromatography–mass spectrometry. Under study conditions, terbuthylazine and S-metolachlor showed the highest leaching potentials. Specifically, S-metolachlor concentrations were always found above 0.25 µg L?1. Desethyl-terbuthylazine was often detected in leached waters, in most cases at concentrations above 0.1 µg L?1. Flufenacet leached only when irrigation occurred close to the time of herbicide spraying. Isoxaflutole and mesotrione were not measured (<0.1 µg L?1), while diketonitrile was detected in concentrations above 0.1 µg L?1 on 1 DAT in 2011 only.  相似文献   

10.
This study assessed bacterial concentrations in indoor air at 25 underground railway stations in Seoul, Korea, and investigated various related factors including the presence of platform screen doors (PSD), depth of the station, year of construction, temperature, relative humidity, and number of passengers. A total of 72 aerosol samples were collected from all the stations. Concentrations of total airborne bacteria (TAB) ranged from not detected (ND) to 4997 CFU m?3, with an overall geometric mean (GM) of 191 CFU m?3. Airborne bacteria were detected at 23 stations (92%) and Gram-negative bacteria (GNB) were detected at two stations (8%). TAB concentrations of four stations (16%) exceeded 800 CFU m?3, the Korea indoor bio-aerosol guideline. The results of the study showed that TAB concentrations at the stations without PSD showed higher TAB concentrations than those with PSD, though not at statistically significant levels. TAB concentrations of deeper stations revealed significantly higher levels than those of shallower stations. Based on this study, it is recommended that mitigation measures be applied to improve the indoor air quality (IAQ) of underground railway stations in Seoul, with focused attention on deeper stations.  相似文献   

11.
The acute and sub-chronic effects of four cytostatic drugs—5-fluorouracil (5-FU), cisplatin (CisPt), etoposide (ET) and imatinib mesylate (IM)—on zebrafish (Danio rerio) were investigated. Acute tests were carried out in a static system in accordance with the OECD guideline 203 for adult fish and the draft guideline for fish embryos (FET test) in order to find the LC50 values of the four cytostatic drugs. Early-life stage toxicity test on zebrafish was conducted according the OECD guideline 210 using the cytostatic drugs 5-FU and IM in a semistatic system with the objective of investigating the sub-chronic effects of the cytostatic drugs on fish. In adult fish, the cytostatic drugs 5-FU and ET did not pass the limit test, thus, are considered non-toxic. In case of cisplatin, LC50 was calculated at 64.5 mg L?1, whereas in case of IM, LC50 was at 70.8 mg L?1. In the FET test, LC50 of 5-FU at 72-h post fertilization (hpf) was 2441.6 mg L?1. In case of CisPt, LC50 was 349.9 mg L?1 at 48 hpf and it progressively decreased to 81.3 mg L?1 at 120 hpf. In addition, CisPt caused a significant delay in the hatch of larvae. In case of ET, LC50 values were not calculable as they were higher than 300 mg L?1 at which concentration the substance crystallized in the solution. LC50 values of IM were 48 hpf; 158.3 mg L?1 , 72 hpf; 141.6 mg L?1, 96 hpf; 118.0 mg L?1, and 120 hpf; 65.9 mg L?1. In the Early-life Stage Test with 5-FU, embryonic deformities were not detected during the tests. Regarding mortalities, the 10 mg L?1 concentration can be considered as LOEC, as statistically significant difference in mortalities was detected in this group alone. Concerning dry body weight and standard length, 1 mg L?1 is the LOEC. In case of IM, the highest tested concentration (10 mg L?1) can be considered LOEC for mortalities, however, the treatment did not have an effect on the other investigated parameters (dry and wet weight, standard length). All four cytostatic drugs were characterized by low toxicity in zebrafish in acute and sub-chronic tests.  相似文献   

12.
Zero-valent iron nanoparticles (nZVI, diameter < 90 nm, specific surface area = 25 m2 g?1) have been used under anoxic conditions for the remediation of pesticides alachlor and atrazine in water. While alachlor (10, 20, 40 mg L?1) was reduced by 92–96% within 72 h, no degradation of atrazine was observed. The alachlor degradation reaction was found to obey first-order kinetics very closely. The reaction rate (35.5 × 10?3–43.0 × 10?3 h?1) increased with increasing alachlor concentration. The results are in conformity with other researchers who worked on these pesticides but mostly with micro ZVI and iron filings. This is for the first time that alachlor has been degraded under reductive environment using nZVI. The authors contend that nZVI may prove to be a simple method for on-site treatment of high concentration pesticide rinse water (100 mg L?1) and for use in flooring materials in pesticide filling and storage stations.  相似文献   

13.
Abstract

The purpose of this study was to assess the effectiveness of a new generation of high-volume, ceiling-mounted high-efficiency particulate air (HEPA)-ultraviolet (UV) air filters (HUVAFs) for their ability to remove or inactivate bacterial aerosol. In an environmentally controlled full-scale laboratory chamber (87 m3), and an indoor therapy pool building, the mitigation ability of air filters was assessed by comparing concentrations of total bacteria, culturable bacteria, and airborne endotoxin with and without the air filters operating under otherwise similar conditions. Controlled chamber tests with pure cultures of aerosolized Mycobacterium parafortuitum cells showed that the HUVAF unit tested provided an equivalent air-exchange rate of 11 hr?1. Using this equivalent air-exchange rate as a design basis, three HUVAFs were installed in an indoor therapy pool building for bioaerosol mitigation, and their effectiveness was studied over a 2-year period. The HUVAFs reduced concentrations of culturable bacteria by 69 and 80% during monitoring periods executed in respective years. The HUVAFs reduced concentrations of total bacteria by 12 and 76% during the same monitoring period, respectively. Airborne endotoxin concentrations were not affected by the HUVAF operation.  相似文献   

14.
A compilation of data from earlier studies of 172 homes in the Pacific Northwest indicated that approximately 65 percent of the 46 homes tested in the Spokane River Valley/Rathdrum Prairie region of eastern Washington/northern Idaho had heating season indoor radon (222Rn) concentrations above the U. S. EPA guideline of 148 Bq m?3 (4 pCi L?1). A subset of 35 homes was selected for additional study. The primary source of indoor radon in the Spokane River Valley/Rathdrum Prairie was pressure-driven flow of soil gas containing moderate radon concentrations (geometric mean concentration of 16,000 Bq m?3) from the highly permeable soils (geometric mean permeability of 5 × 10?11 m2) surrounding the house substructures. Estimated soil gas entry rates ranged from 0.4 to 39 m3h?1 and 1 percent to 21 percent of total building air infiltration. Radon from other sources, including domestic water supplies and building materials was negligible. In high radon homes, winter indoor levels averaged 13 times higher than summer concentrations, while in low radon homes winter levels averaged only 2.5 times higher. Short-term variations in indoor radon were observed to be dependent upon indoor-outdoor temperature differences, wind speed, and operation of forced-air furnace fans. Forced-air furnace operation, along with leaky return ducts and plenums, and openings between the substructure and upper floors enhanced mixing of radon-laden substructure air throughout the rest of the building.  相似文献   

15.

Purpose

Bacterial community structure and the chemical components in aerosols caused by rotating brushes in an Orbal oxidation ditch were assessed in a Beijing municipal wastewater treatment plant.

Methods

Air samples were collected at different distances from the aerosol-generating rotating brushes. Molecular culture-independent methods were used to characterize the community structure of the airborne bacteria in each sample regardless of cell culturability. A clone library of 16S rDNA directly amplified from air DNA of each sample was constructed and sequenced to analyze the community composition and diversity. Insoluble particles and water-soluble ions emitted with microorganisms in aerosols were analysis by a scanning electron microscope together with energy dispersive X-ray spectroscopy and ion chromatogram analyzer.

Results

In total, most of the identified bacteria were Proteobacteria. The majority of sequences near the rotating brushes (the main source of the bioaerosols) were Proteobacteria (62.97 %) with ??-(18.52 %) and ??-(44.45?%) subgroups and Bacteroidetes (29.63 %). Complex patterns were observed for each sampling location, suggesting a highly diverse community structure, comparable to that found in water in the Orbal oxidation ditch. Accompany with microorganisms, 46.36???g/m3 of SO 4 2? , 29.35???g/m3 of Cl?, 21.51???g/m3 of NO 3 ? , 19.76???g/m3 of NH 4 + , 11.42???g/m3 of PO 4 3? , 6.18???g/m3 of NO 2 ? , and elements of Mg, Cl, K, Na, Fe, S, and P were detected from the air near the aerosols source.

Conclusions

Differences in the structure of the bacterial communities and chemical components in the aerosols observed between sampling sites indicated important site-related variability. The composition of microorganisms in water was one of the most important sources of bacterial communities in bioaerosols. Chemical components in bioaerosols may provide a media for airborne microorganism attachment, as well as a suitable microenvironment for their growth and survival in the air. This study will be benefit for the formulation of pollution standards, especially for aerosols, that take into account plant workers?? health.  相似文献   

16.
The objective of this study was to determine the acute toxicity of some pesticides used in irrigated rice farming to Lithobates catesbeianus tadpoles. The LC50-96h for commercial formulations containing bentazon, penoxsulam, vegetable oil, permethrin and carbofuran, separately and their mixtures, were determined at the proportions commonly used in the field. The limits of risk concentrations of these products for the studied species were also established. The LC50-96h for tadpoles was 4,530 mg L?1 for bentazon; 7.52 mg L?1 for penoxsulam + 145.66 mg L?1 of vegetable oil; 81.57 mg L?1 for vegetable oil; 0.10 mg L?1 for permethrin; 29.90 mg L?1 for carbofuran (active ingredients), and 38.79 times the dose used in the field for the mixture of these products. The environmental risk was determined only for permethrin, and care should be taken when using the vegetable oil.  相似文献   

17.
Residences located within 20 km of the damaged Fukushima Daiichi Nuclear Power Plant were evacuated shortly after the Great East Japan Earthquake. The levels of airborne and surface fungi were measured in six houses in the evacuation zone in August 2012 and February 2013. Airborne fungal levels in all of the houses in the summer were higher than the environmental standard levels for residential houses published in Architectural Institute of Japan (>1000 colony-forming units [CFU]/m3). In two houses whose residents rarely returned to visit, fungal levels were extremely high (>52,000 CFU/m3). Although fungal levels in the winter were much lower than those in the summer, they were still higher than environmental standard levels in several houses. Indoor fungal levels were significantly inversely related to the frequency with which residents returned, but they were not correlated with the air exchange rates, temperature, humidity, or radiation levels. Cladosporium spp. and Penicillium spp. were detected in every house. Aspergillus section Circumdati (Aspergillus ochraceus group) was also detected in several houses. These fungi produced ochratoxin A and ochratoxin B, which have nephrotoxic and carcinogenic potential. The present study suggests that further monitoring of fungal levels is necessary in houses in the Fukushima Daiichi Nuclear Power Plant evacuation zone, and that some houses may require fungal disinfection.

Implications: The results suggest that residents’ health could be at risk owing to the high levels of airborne fungi and toxic fungi Aspergillus section Circumdati. Therefore, monitoring and decontamination/disinfection of fungi are strongly recommended before residents are allowed to return permanently to their homes. In addition, returning to home with a certain frequency and adequate ventilation are necessary during similar situations, e.g., when residents cannot stay in their homes for a long period, because fungal levels in houses in the Fukushima Daiichi Nuclear Power Plant evacuation zone were inversely correlated with the frequency with which residents returned to visit their houses.  相似文献   


18.
By enrichment culturing of soil contaminated with metribuzin, a highly efficient metribuzin degrading bacterium, Bacillus sp. N1, was isolated. This strain grows using metribuzin at 5.0% (v/v) as the sole nitrogen source in a liquid medium. Optimal metribuzin degradation occurred at a temperature of 30ºC and at pH 7.0. With an initial concentration of 20 mg L?1, the degradation rate was 73.5% in 120 h. If the initial concentrations were higher than 50 mg L?1, the biodegradation rates decreased as the metribuzin concentrations increased. When the concentration was 100 mg L?1, the degradation rate was only 45%. Degradation followed the pesticide degradation kinetic equation at initial concentrations between 5 mg L?1 and 50 mg L?1. When the metribuzin contaminated soil was mixed with strain N1 (with the concentration of metribuzin being 20 mg L?1 and the inoculation rate of 1011 g?1 dry soil), the degradation rate of the metribuzin was 66.4% in 30 days, while the degradation rate of metribuzin was only 19.4% in the control soil without the strain N1. These results indicate that the strain N1 can significantly increase the degradation rate of metribuzin in contaminated soil.  相似文献   

19.
The temporal and spatial distribution characteristics of environmental parameters and the phytoplankton community were investigated in October 2010 and January 2011 in the Qinhuai River, Nanjing, China. Results showed that the water quality in the study area was generally poor, and the main parameters exceeding standards (level V) were nitrogen and phosphorus. The observed average concentrations of the total nitrogen (TN) were 4.90 mg?L?1 in autumn and 9.29 mg?L?1 in winter, and those of the total phosphorus (TP) were 0.24 mg?L?1 in autumn and 0.88 mg?L?1 in winter, respectively. Thirty-seven species, 30 genera, and four phyla of phytoplankton were detected in the river. Cyanophyta and Bacillariophyta were the dominant phyla in autumn, with average abundance and biomass of 221.5?×?104?cells?L?1 and 4.41 mg?L?1, respectively. The dominant population in winter was Bacillariophyta, and the average abundance and biomass were 153.4?×?104?cells?L?1 and 6.58 mg?L?1, respectively. The results of canonical correspondence analysis (CCA) between environmental parameters and phytoplankton communities showed that Chlorophyta could tolerate the higher concentrations of the permanganate index, nitrogen, and phosphorus in eutrophic water; Bacillariophyta could adapt well to changing water environments; and the TN/TP ratio had obvious impacts on the distributions of Cyanophyta, Euglenophyta, and some species of Chlorophyta. CCA analyses for autumn and winter data revealed that the main environmental parameters influencing phytoplankton distribution were water temperature, conductivity, and total nitrogen, and the secondary factors were dissolved oxygen, NH4 +–N, NO3–N, TN, CODMn, TN/TP ratio, and oxidation-reduction potential.  相似文献   

20.
Field isolates of Didymella applanata, the causal agent of spur blight of raspberry, were evaluated in vitro for their sensitivity to mancozeb, chlorothalonil, captan, fluopyram, boscalid and difenoconazole. A total of 10 isolates, collected during 2013 at five localities in the major raspberry growing region in Serbia, and characterized as copper hydroxide, dithianon, and tebuconazole (sensitive), pyraclostrobin (sensitive or highly resistant) and fluazinam (sensitive or moderately resistant), were used in this study. The EC50 values for the isolates ranged from 1.33 to 2.88 mg L?1 for mancozeb, from 3.18 to 6.65 mg L?1 for chlorothalonil, from 15.75 to 24.69 mg L?1 for captan and from 1.80 to 8.20 mg L?1 for fluopyram. The narrowest range of EC50 values was recorded for difenoconazole (0.23–0.49 mg L?1), whereas the widest range was obtained for boscalid (4.49–49.25 mg L?1). The calculated resistance factors showed that all D. applanata isolates were sensitive to mancozeb, chlorothalonil, captan, and difenoconazole. Four isolates were moderately resistant to boscalid, while three of them were also moderately resistant to fluopyram. This finding of moderately resistant isolates to these SDHI fungicides indicates a possible cross-resistance which should be clarified in further investigations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号