首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 761 毫秒
1.
Various methods that are available for estimating the explosion venting requirements of weak dust handling equipment are compared. The regression analysis that Simpson has performed on the well known Kst nomographs is shown to extend to Kst values less than 50 bar m s−1 and to reduced explosion pressures between 1.1 bar a and 1.2 bar a.  相似文献   

2.
The relief of a gas explosion in a tubular vessel by venting can be predicted by using a mathematical model. In this model, the flame acceleration is represented by an increase in the burning velocity. The movement of a vent cover can be included. The model assumes that the vent is blocked by the vent cover prior to the explosion. the venting ratio was the most influential parameter in terms of relieving the pressure. In the case of a large venting ratio, the flame acceleration made a highly significant contribution, whereas for small venting ratios, the weight of the vent cover contributed to the relief more than the flame acceleration. When the pressure is required to be reduced significantly, the venting ratio, the vent open pressure and the weight of the vent cover must all be reduced.  相似文献   

3.
The authors investigated the ignitability of aluminium and magnesium dusts that are generated during the shredding of post-consumer waste. The relations between particle size and the minimum explosive concentration, the minimum ignition energy, the ignition temperature of the dust clouds, etc. the relation between of oxygen concentration and dust explosion, the effect of inert substances on dust explosion, etc. were studied experimentally.

The minimum explosive concentration increased exponentially with particle size. The minimum explosive concentrations of the sample dusts were about 170 g/m3 (aluminium: 0–8 μm) and 90 g/m3 (magnesium: 0–20 μm). The minimum ignition energy tended to increase with particle size. It was about 6 mJ for the aluminium samples and 4 mJ for the magnesium samples. The ignition temperature of dust clouds was about 750 °C for aluminium and about 520 °C for magnesium. The lowest concentrations of oxygen to produce a dust explosion were about 10% for aluminium and about 8% for magnesium. A large mixing ratio (more than about 50%) of calcium oxide or calcium carbonate was necessary to decrease the explosibility of magnesium dust. The experimental data obtained in the present investigation will be useful for evaluating the explosibility of aluminium and magnesium dusts generated in metal recycling operations and thus for enhancing the safety of recycling plants.  相似文献   


4.
Ducts are often recommended in the design of dust explosion venting in order to discharge materials to safe locations. However, the maximum reduced overpressure increases in a duct-vented vessel rather than in a simply vented vessel. This needs to be studied further for understanding the duct-venting mechanism. Numerous duct-vented dust explosion experiments were conducted, using a 20 L spherical chamber at elevated static activation overpressures, ranging from 1.8 bar to 6 bar. Duct diameters of 15 mm and 28 mm, and duct lengths of 0 m (simply venting), 1 m and 2 m, were selected. Explosion pressures both in the vessel and in the duct were recorded by pressure sensors, with a frequency of 5 kHz. Flame signals in the duct were also obtained by phototransistors. Results indicate that the secondary explosion occurring in the duct increases the maximum reduced overpressure in the vessel. The secondary explosion is greatly affected by the duct diameter and static activation overpressure, and hence influences the amplification of the maximum reduced overpressure. Larger static activation overpressure decreases the severity of the secondary explosion, and hence decreases the increment in the maximum reduced overpressure. The secondary pressure peak is more obvious as the pressure accumulation is easier in a duct with a smaller diameter. However, the increment of the maximum reduced overpressure is smaller because blockage effect, flame front distortion, and turbulent mixing due to secondary explosion are weaker in a narrow duct. The influence of duct length on the maximum reduced overpressure is small at elevated static activation overpressures, ranging from 1.8 bar to 6 bar at 15 mm and 28 mm duct diameters.  相似文献   

5.
The effect of the vent burst pressure on explosion venting of a rich methane-air mixture was experimentally investigated in a small cylindrical vessel. The experimental results show that Helmholtz oscillation of the internal flame bubble of the methane-air mixture can occur in a vessel with a vent area much smaller than that reported by previous researchers, and the period of Helmholtz oscillation decreases slightly when the vent burst pressure increases. The maximum overpressure in the vessel increases approximately linearly with the increase in the vent burst pressure; however, the pressure peaks induced by Helmholtz oscillation always remain approximately several kilopascals. The external flame reaches its maximum length in a few milliseconds after vent failure and then oscillates in accordance with the pressure oscillation in the vessel. The maximum length of the external flame increases, but its duration time decreases with the increase in the vent burst pressure.  相似文献   

6.
In this study, the confined explosion characteristics of ethyl acetate were investigated in a constant volume explosion vessel using the initial pressure of 1–4 bar, the initial temperature of 358–418 K, and the equivalence ratio of 0.8–1.4. It was revealed that the peak explosion pressure and the maximum pressure rise rate of ethyl acetate increased as the initial pressure increased and the initial temperature decreased. The peak explosion pressure and maximum pressure rise rate were obtained at the equivalence ratio of 1.2 due to increased heat release rate. Furthermore, the explosion time decreased as the initial pressure decreased. In summation, EA experimental and theoretical deflagration index were investigated and compared. The experimental deflagration index showed that EA explosion was less dangerous, whereas the theoretical deflagration predicted that the explosion could be more hazardous.  相似文献   

7.
Decomposing deflagration properties of acetylene under low temperatures   总被引:1,自引:0,他引:1  
In this study, the decomposing deflagration properties of acetylene under temperatures down to −60 °C and pressures up to 0.2 MPa in a 1-L cylindrical closed vessel were experimentally investigated. The gases were ignited by an electric spark at the center of the vessel. The lower-limit pressures of decomposing deflagration by electric spark ignition were determined. The lower-limit pressure at 10 °C was 0.15 MPa, and it gradually increased with decreasing temperature. The lower-limit pressure at −60oC was 0.18 MPa. The flame propagation properties, such as the pressure, were measured with pressure transducers mounted along the vessel. The maximum decomposing deflagration pressures and pressure rising rates also increased with decreasing temperature.  相似文献   

8.
Hydrogen-enrichment has been proposed as a useful method to overcome drawbacks (local flame extinction, combustion instabilities, lower power output, etc.) associated to turbulent premixed combustion of natural gas in both stationary and mobile systems. For the safe use of hydrogen-enriched hydrocarbon fuels, explosion data are needed.In this work, a comparative experimental study of the explosion behavior of stoichiometric hydrogen-enriched methane/air (with 10% of hydrogen molar content in the fuel) and pure methane/air mixtures is presented. Tests were carried out in a 5 l closed cylindrical vessel at different initial pressures (1, 3 and 6 bar), and starting from both quiescent and turbulent conditions.Results allow quantifying the combined effects of hydrogen substitution to methane, pressure and turbulence on maximum pressure, maximum rate of pressure rise, burning velocity and Markstein lengths.  相似文献   

9.
Scaling parameters for vented gas and dust explosions   总被引:3,自引:0,他引:3  
Results of experiments or calculations for vented explosions are usually presented by expressing a term containing the peak (reduced) pressure as a function of a vent parameter. In gas explosions, the reactivity of the system has been typically characterized through an effective burning velocity, uf. In the case of dust explosions, a normalized peak rate of pressure rise, K(=V1/3(dp/dt)max), has been used instead. Depending on the chosen approach, comparisons between systems with the same “reactivity” take different meanings. In fact, correlation formulas resulting from these two approaches imply different scaling between important system parameters. In the case of a constant-uf system, and for sufficiently large vent areas, the reduced pressure, Δpr, is approximately proportional to the square of the peak unvented pressure, Δpm. On the other hand, correlations developed for constant-K systems imply proportionality of Δpr with Δpm raised to a power between −5/3 and −1, with the exact value depending on the assumptions made on the shape of the pressure profile. While the ultimate resolution of the details of the scaling may require recourse to experiments, this theoretical analysis offers a tool for the planning of such experiments and for the interpretation of their results. The paper provides a discussion of these scaling issues with the help of predictions from an isothermal model of vented explosions.  相似文献   

10.
To further understand the dynamic mechanism of dust explosion through a vent duct, we designed a small-scale cylindrical vessel connected with a vent duct and performed a dust explosion venting experiment under different opening pressures using corn starch as the explosive medium in this study. The results show that weakening effect of duct on venting is positively correlated with the opening pressure. The explosion pressure in the duct presents a three-peak-structure with time, successively caused by the membrane breaking shock wave, the secondary explosion in the tube, and the continuous combustion, and decreases gradually with the propagation distance. Meanwhile, the three pressure peaks are positively correlated with the opening pressure, while the time interval between them goes to contrary. The increase of opening pressure leads to the increase of secondary explosion intensity and reverse flow in the vessel, further accelerates the reaction rate in the vessel, and then shortens the duration of combustion in the vessel until the phenomenon of flame reignition in the vessel disappears.  相似文献   

11.
为了解泄爆容器中粉尘爆炸的发展过程,采用试验和数值模拟相结合的方法对玉米淀粉在圆柱形容器内的泄爆过程进行研究。数值模型采用欧拉–拉格朗日方法模拟粉尘爆炸的两相流问题,通过求解非稳态的湍流两相反应流守恒方程对试验进行二维仿真。试验和模拟结果表明,点火位置对爆炸发展过程有明显影响,点火位置离泄爆口越远,容器中的最大泄爆压力Pred,max越高。在粉尘爆炸的安全防护设计中,应把点火位置作为重要影响因素之一加以考虑。  相似文献   

12.
A study on the obstacle-induced variation of the gas explosion characteristics   总被引:13,自引:0,他引:13  
A study on the variation of the gas explosion characteristics caused by the built-in obstacles was conducted in enclosed/vented gas explosion vessels. It has been well known that the obstacles in pipes and long ducts would accelerate the flame propagation, and cause the transition from deflagration to detonation. In this study, the explosion characteristics and the flame behavior of vented explosions and constant-volume explosions were investigated. Experiments were carried out in a 270-liter and 36-liter hexahedron vessels filled with LPG–air mixture. The explosion characteristics of the gas mixture were determined by using a strain-responding pressure transducer. The flame behavior was recorded by using a high-speed video camera. The shape and the size of the obstacle, and the gas concentration, were adjusted in the experiments.

It can be seen from the experimental results that, instead of being accelerated, the flame propagation inside the explosion vessel is decelerated by the plate obstacles fixed at the bottom of the vessel. Also, the characteristics of the enclosed explosion are not so affected by the built-in obstacles as those of the vented explosion are. It is believed that the eddy-induced turbulence behind the obstacle decelerates the flame propagation.  相似文献   


13.
Flame speeds and rates of pressure rise for gaseous explosions in a 76 mm diameter closed cylindrical vessel of large length to diameter ratio (L/D = 21.6), were quantitatively investigated. Methane, propane, ethylene and hydrogen mixtures with air were studied across their respective flammability ranges. Ignition was affected at one end of the vessel. Very fast flame speeds corresponding to high rates of pressure rise were measured in the initial 5–10% of the total explosion time. During this period 20–35% of the maximum explosion pressure was produced, and over half of the flame propagation distance was completed. Previous work has concentrated on the later stages of this type of explosion; the development of tulip flames, pressure wave effects and transition to turbulence. The initial fast phase is very important and should dominate considerations in pressure relief vent design for vessels of large L/D.  相似文献   

14.
On the basis of a systematic testwork with a number of different dusts, the explosion indices as determined within the 20 l sphere and with the ISO-VDI 1 m3 vessel have been compared. The repeatability has been assessed and since some systematic deviations appear a refined physical analysis of the explosion processes is developed. It appears in particular that the cube root law supposed to link both vessels is not verified. A striking illustration of this appears when a dust with a significant explosion severity inside the 20 l sphere is not even explosible in the larger vessel. It is strongly suggested that the ignition energy is forcing very significantly the explosion in the smaller vessel inducing several tens of Celsius degrees of preheating. It is shown also that the inner level of turbulence is decreasing very fast in the 20 l sphere during the flame development so that difficult-to-ignite mixtures would tend to burn at a lower combustion rate. It is further demonstrated that the major bias between the chambers can be explained and quantified with these elements. A correlation with the standard 1 m3 vessel and a grid of interpretation of the data is proposed.  相似文献   

15.
Innovative vent sizing technology is presented for explosion safety design of equipment at atmospheric and elevated initial pressures. Unified correlations for vent sizing are suggested. They are modifications of previously reported correlations verified thoroughly for experimental data on vented gaseous deflagrations under different conditions but only at initial atmospheric pressure. Suggested correlations are based on experimental data on vented deflagrations of quiescent and turbulent propane–air mixtures at initial pressures up to 0.7 MPa. Typical values of turbulence factor and deflagration–outflow interaction number are obtained for experimental vented deflagrations at initial pressures higher than atmospheric.

“Blind” examination of new vent sizing technology on another set of experiments with methane–air and propane–air mixtures has shown that predictions by suggested vent sizing technology are better than by the NFPA 68 guide for “Venting of Deflagrations”.

In the development of recently reported results for initial atmospheric pressure it has been concluded that the innovative vent sizing technology is more reliable compared to the NFPA 68 guide at elevated initial pressures as well. Moreover it is crucial that the calculation procedure remains the same for arbitrary deflagration conditions.  相似文献   


16.
A typical building consists of a number of rooms; often with windows of different size and failure pressure and obstructions in the form of furniture and décor, separated by partition walls with interconnecting doorways. Consequently, the maximum pressure developed in a gas explosion would be dependent upon the individual characteristics of the building. In this research, a large-scale experimental programme has been undertaken at the DNV GL Spadeadam Test Site to determine the effects of vent size and congestion on vented gas explosions. Thirty-eight stoichiometric natural gas/air explosions were carried out in a 182 m3 explosion chamber of L/D = 2 and KA = 1, 2, 4 and 9. Congestion was varied by placing a number of 180 mm diameter polyethylene pipes within the explosion chamber, providing a volume congestion between 0 and 5% and cross-sectional area blockages ranging between 0 and 40%. The series of tests produced peak explosion overpressures of between 70 mbar and 3.7 bar with corresponding maximum flame speeds in the range 35–395 m/s at a distance of 7 m from the ignition point. The experiments demonstrated that it is possible to generate overpressures greater than 200 mbar with volume blockages of as little as 0.57%, if there is not sufficient outflow through the inadvertent venting process. The size and failure pressure of potential vent openings, and the degree of congestion within a building, are key factors in whether or not a building will sustain structural damage following a gas explosion. Given that the average volume blockage in a room in a UK inhabited building is in the order of 17%, it is clear that without the use of large windows of low failure pressure, buildings will continue to be susceptible to significant structural damage during an accidental gas explosion.  相似文献   

17.
Dust explosion venting experiments were performed using a 20-L spherical chamber at elevated static activation overpressures larger than 1 bar. Lycopodium dust samples with mean diameter of 70 μm and electric igniters with 0.5 KJ ignition energy were used in the experiments. Explosion overpressures in the chamber and flame appearances near the vent were recorded simultaneously. The results indicated that the flame appeared as the under-expanded free jet with shock diamonds, when the overpressure in the chamber was larger than the critical pressure during the venting process. The flame appeared as the normal constant-pressure combustion when the pressure venting process finished. Three types of venting processes were concluded in the experiments: no secondary flame and no secondary explosion, secondary flame, secondary explosion. The occurrence of the secondary explosions near the vent was related to the vent diameter and the static activation overpressure. Larger diameters and lower static activation overpressures were beneficial to the occurrence of the secondary explosions. In current experiments, the secondary explosions only occurred at the following combinations of the vent diameter and the static activation overpressure: 40 mm and 1.2 bar, 60 mm and 1.2 bar, 60 mm and 1.8 bar.  相似文献   

18.
Experiments of explosion venting in different conditions were performed in a cylindrical vessel with a vent duct; the pressure-time profiles from four transducers mounted in the line-of-sight centerline outside the vessel and the clear sequential shadowgraphs of external venting flow field taken by a high-speed shadowgraph imaging system were obtained. Based on these results, the characteristics of the external pressure field during venting were discussed systematically to explain the generation mechanism of the secondary explosion. In addition, the variations of the intensity of the secondary explosion in different venting conditions, namely the failure pressure, ignition location, area blockage ratio or equivalence ratio of the fuel, were also analyzed in detail.  相似文献   

19.
The paper outlines an experimental study of influence of the ignition position and obstacles on explosion development in premixed methane–air mixtures in an elongated explosion vessel. As the explosion vessel, 1325 mm length tube with 128.5 mm diameter was used. Location of the ignition was changeable, i.e., fitted in the centre or at one of ends of the tube, when the tube was in a horizontal position. When it was in a vertical position, three locations of the ignition (bottom, centre and top) were used. In the performed study, the influence of obstacles on the course of pressure was investigated. Two identical steel grids were used as the obstacles. They were placed 405 mm from either end of the tube. Their blockage ratio (grid area to tube cross-section area) was determined as 0.33 for most of experiments. A few additional experiments (with smaller blockage ratio—0.16) were also conducted in order to compare the influence of the blockage ratio on the explosion development. Also some experiments were conducted in a semi-cylindrical vessel with volume close to 40 l.

All the experiments were performed under stabilized conditions, with the temperature and pressure inside the vessel settled to room values and controlled by means of electronic devices. The pressure–time profiles from two transducers placed in the centreline of the inner wall of the explosion vessel were obtained for stoichiometric (9.5%), lean (7%) and rich (12%) methane–air mixture. The results obtained in the study, including maximum pressures and pressure–time profiles, illustrate a quite distinct influence of the above listed factors upon the explosion characteristics. The effect of ignition position, obstacles location and their BR parameters is discussed.

The additional aim of the performed experiments was to find the data necessary to validate a new computer code, developed to calculate an explosion hazard in industrial installations.  相似文献   


20.
Flameless venting is a sort of dual mitigation technique allowing, in principle, to vent a process vessel inside a building where people are working without transmitting a flame outside the protected vessel. Existing devices are an assembly of a vent panel and a metal filter so that the exploding cloud and the flame front is forced to go through the filter. Within the frame of ATEX Directive, those systems need to be certified. To do so a standard (NF EN 16009) has been issued describing which criteria need to be verified/measured. Among them, the “efficiency” factor as defined earlier for standard vents. This implies that flameless venting systems are basically considered as vents. But is it really so? This question is discussed on the basis of experimental results and some implications on the practical use and certification process are drawn. The practical experience of INERIS in testing such systems is presented in this paper. Schematically, with a flameless vent the pressure is discharged but not the flame so that combustion is proceeding to a much longer extent inside the vessel than with a classical vent so that the physics of the explosion is different. In particular it is shown that besides the problem of the unloading of the confined explosion, there is a highly complicated fluid mechanics problem of a fluid-particle flow passing through a porous media (the flameless device grids arrangement in the filter), which passing surface is progressively reduced. To characterize Flameless venting the problem can be addressed sequentially, considering separately the vent panel and the flameless mesh. A model is proposed to estimate the overall venting efficiency of the flameless vent. However, it does not address the flame quenching issue, which is a different problem of heat exchange between the devices and the evacuated burnt products.  相似文献   