1.
Abstract

A polysulfone microporous membrane module was investigated for control of 1-butanol-contaminated gas streams. A diurnal loading condition, using two different butanol concentrations, was used to simulate startup and stop conditions associated with shift work. The membrane module was also used to remove 1-butanol from air under continuous loading conditions in a bioreactor. The reactors were seeded with a mixed bacterial consortium capable of butanol biodegradation. Biokinetic parameters for butanol utilization were determined for the culture to be a maximum specific utilization rate (k) equal to 4.3 d?1 and a half saturation constant (Ks) equal to 8.9 mg L?1. A biofilter running only with diurnal loading conditions giving a “40-hr workweek” had an average 1-butanol removal rate of 29% (111 ppm, 74 gm?3 hr?1) from a 350-ppm influent at the end of an 8-hr operational day. End-of-day removal varied between 4 and 67% during the operational period. With continuous steady-state operation followed by placement on a diurnal loading schedule and influent butanol concentrations increased to 700 ppm, butanol removal averaged 38% (269 ppm, 145 gm?3 hr?1). Under continuous loading, steady-state conditions, 1-butanol removal from the airstream was greater than 99% (200 ppm, 73 gm?3 hr?1). These results suggest that the bioreactor can be operated on a diurnal schedule or 40-hr week operational schedule without any decline in performance.  相似文献   

2.
Two biofilters were operated to treat a waste gas stream intended to simulate off-gases generated during the manufacture of reformulated paint. The model waste gas stream consisted of a five-component solvent mixture containing acetone (450 ppm(v)), methyl ethyl ketone (12 ppm(v)), toluene (29 ppm(v)), ethylbenzene (10 ppm(v)), and p-xylene (10 ppm(v)). The two biofilters, identical in construction and packed with a polyurethane foam support medium, were inoculated with an enrichment culture derived from compost and then subjected to different loading conditions during the startup phase of operation. One biofilter was subjected to intermittent loading conditions with contaminants supplied only 8 hr/day to simulate loading conditions expected at facilities where manufacturing operations are discontinuous. The other biofilter was subjected to continuous contaminant loading during the initial start period, and then was switched to intermittent loading conditions. Experimental results demonstrate that both startup strategies can ultimately achieve high contaminant removal efficiency (>99%) at a target contaminant mass loading rate of 80.3 g m(-3) hr(-1) and an empty bed residence time of 59 sec. The biofilter subjected to intermittent loading conditions at startup, however, took considerably longer to reach high performance. In both biofilters, ketone components (acetone and methyl ethyl ketone) were, more rapidly degraded than aromatic hydrocarbons (toluene, ethylbenzene, and p-xylene). Scanning electron microscopy and plate count data revealed that fungi, as well as bacteria, populated the biofilters.  相似文献   

3.
Hydrogen sulfide (H2S) is one of the most toxic and offensively odorous gases and is generated in anaerobic bioreactors. A middle-thermophilic sulfur-oxidizing bacterium (SOB), Thiomonas sp. strain RAN5, was isolated and applied for H2S removal from both artificial and anaerobically digested gas. When a bioreactor containing medium inoculated with RAN5 was aerated continuously with artificial gas (containing 100 ppm H2S) at 45 degrees C for 156 hr, the H2S concentration in the vented gas was reduced by 99%. This was not affected by the presence of other microbes in the bioreactor The H2S removal efficiency of the RAN5 bioreactor for anaerobically digested gas was greater than 99% at influent H2S concentrations ranging from 2 to 1800 ppm; the efficiency decreased to 90% at influent H2S concentrations greater than 2000 ppm. Thiomonas sp. strain RAN5 cannot survive at room temperature, and thus its leakage from a wastewater treatment plant would not damage sewage systems. These data suggest that Thiomonas sp. strain RAN5 may be a useful microorganism for H2S removal.  相似文献   

4.
Gas mixtures of H2S and NH3 are the focus of this study of research concerning gases generated from animal husbandry and treatments of anaerobic wastewater lagoons. A heterotrophic microflora (a mixture of Pseudomonas putida for H2S and Arthrobacter oxydans for NH3) was immobilized with Ca-alginate and packed into a fluidized bed reactor to simultaneously decompose H2S and NH3. This bioreactor was continuously supplied with H2S and NH3 separately or together at various ratios. The removal efficiency, removal rate, and metabolic product of the bioreactor were studied. The results showed that the efficiency remained above 95% when the inlet H2S concentration was below 30 ppm at 36 L/hr. Furthermore, the apparent maximum removal and the apparent half-saturation constant were 7.0 x 10(-8) g-S/cell/day and 76.2 ppm, respectively, in this study. The element sulfur as a main product prevented acidification of the biofilter, which maintained the stability of the operation. As for NH3, the greater than 90% removal rate was achieved as long as the inlet concentration was controlled below 100 ppm at a flow rate of 27 L/hr. In the NH3 inlet, the apparent maximum removal and the apparent half-saturation constant were 1.88 x 10(-6) g-N/cell/day and 30.5 ppm, respectively. Kinetic analysis showed that 60 ppm of NH3 significantly suppressed the H2S removal by Pseudomonas putida, but H2S in the range of 5-60 ppm did not affect NH3 removal by Arthrobacter oxydans. Results from bioaerosol analysis in the bioreactor suggest that the co-immobilized cell technique applied for gas removal creates less environmental impact.  相似文献   

5.
Biotrickling filtration of nitric oxide   总被引:21,自引:0,他引:21  
A biotrickling filter with blast-furnace slag packings (sizes = 20-40 mm and specific surface area = 120 m2/m3) was utilized to treat NO in an air stream. The operational stability, as well as the effects of gas empty-bed retention time (EBRT) and nutrient addition on the removal ability of NO, were tested. Approximately six weeks were required for the development of a biofilm for NO degradation, and a two-week organic carbon deficiency resulted in the detachment of biofilms from the packing surfaces. A steady removal rate of 80% was attained at specified influent NO concentrations of 892 to 1237 ppm and an EBRT of 118 sec. The effluent NO concentration diminished exponentially with enlarging EBRT, with influent NO concentrations of 203-898 ppm, and EBRTs of 25 to 118 sec. Nutrient addition is essential for efficient removal of the influent NO. Mass ratios of C: P: N = 7: 1: 30 and NaHCO3: NO-N = 6.3 could be used for practical applications.  相似文献   

6.
A portable 1-butanol olfactometer was developed for quantifying odors in ambient air. Panelists compare the intensity of ambient odors with the intensity of discrete levels of 1-butanol provided by the olfactometer. Range of delivered 1-butanol concentrations Is 0 to 80 ppm in air at a flow rate of 15 L/min. Laboratory tests were performed to ascertain overall precision, consistency of panelist responses, uniqueness of each odor step, variability between two Identical olfactometers, and effect of delivery method. For 855 pairs of matched odor Intensities, the ratio of measured butanol concentration to set concentration averaged 0.984 or —0.023 scale steps (where the scale steps differ In concentration by factors of two). In field experiments the equivalent ambient odor Intensities determined by odor panels using the butanol olfactometer ranged from 1.5 ppm to 64 ppm of 1-butanol vapor In air. The precision of ambient odor measurements was within one-half scale step on the 1-butanol olfactometer, sufficient for most odor investigation and abatement research applications.  相似文献   

7.
Biofiltration has been increasingly used for cleaning waste gases, mostly containing low concentrations of odorous compounds. To expand the application area of this technology, the biofiltration of higher pollutant loading rates has to be investigated. This article focuses on the biodegradation of isobutanal (IBAL) in a compost biofilter (BF) at mass loading rates between 211 and 4123 g/m3/day (30-590 ppm(v)). At mass loading rates up to 785 g/m3/day, near 100% removal efficiencies could be obtained. However, after increasing the loading rate to 1500-1900 g/m3/ day, the degradation efficiency decreased to 62-98%. In addition, a pH decrease and production of isobutanol (IBOL) and isobutyric acid (IBAC) were observed. This is the first report showing that an aldehyde can act as electron donor as well as acceptor in a BF. To study the effects of pH, compost moisture content, and electron acceptor availability on the biofiltration of IBAL, IBOL, and IBAC, additional batch and continuous experiments were performed. A pH of 5.2 reduced the IBAL degradation rate and inhibited the IBOL degradation, although adaptation of the microorganisms to low pH was observed in the BFs. IBAC was not degraded in the batch experiments. High moisture content (51%) initially had no effect on the IBOL production, although it negatively affected the IBAL elimination increasingly during a 21-day time-course experiment. In batch experiments, the reduction of IBAL to IBOL did not decrease when the amount of available electron acceptors (oxygen or nitrate) was increased. The IBAL removal efficiency at higher loading rates was limited by a combination of nutrient limitation, pH decrease, and dehydration, and the importance of each limiting factor depended on the influent concentration.  相似文献   

8.
ABSTRACT

A biotrickling filter with blast-furnace slag packings (sizes = 20-40 mm and specific surface area = 120 m2/m3) was utilized to treat NO in an air stream. The operational stability, as well as the effects of gas empty-bed retention time (EBRT) and nutrient addition on the removal ability of NO, were tested. Approximately six weeks were required for the development of a biofilm for NO degradation, and a two-week organic carbon deficiency resulted in the detachment of biofilms from the packing surfaces. A steady removal rate of 80% was attained at specified influent NO concentrations of 892 to 1237 ppm and an EBRT of 118 sec. The effluent NO concentration diminished exponentially with enlarging EBRT, with influent NO concentrations of 203-898 ppm, and EBRTs of 25 to 118 sec. Nutrient addition is essential for efficient removal of the influent NO. Mass ratios of C: P: N = 7: 1: 30 and NaHCO3: NO-N = 6.3 could be used for practical applications.  相似文献   

9.
This work considers the oxidation of ammonia (NH3) by selective catalytic oxidation (SCO) over a copper (Cu)-cerium (Ce) composite catalyst at temperatures between 150 and 400 degrees C. A Cu-Ce composite catalyst was prepared by coprecipitation of copper nitrate and cerium nitrate at various molar concentrations. This study also considers how the concentration of influent NH3 (500-1000 ppm), the space velocity (72,000-110,000 hr(-1)), the relative humidity (12-18%) and the concentration of oxygen (4-20%) affect the operational stability and the capacity for removing NH3. The effects of the O2 and NH3 content of the carrier gas on the catalyst's reaction rate also are considered. The experimental results show that the extent of conversion of NH3 by SCO in the presence of the Cu-Ce composite catalyst was a function of the molar ratio. The NH3 was removed by oxidation in the absence of Cu-Ce composite catalyst, and approximately 99.2% NH3 reduction was achieved during catalytic oxidation over the Cu-Ce (6:4, molar/molar) catalyst at 400 degrees C with an O2 content of 4%. Moreover, the effect of the initial concentration and reaction temperature on the removal of NH3 in the gaseous phase was also monitored at a gas hourly space velocity of less than 92,000 hr(-1).  相似文献   

10.
Dichloromethane (DCM, also known as methylene chloride [CH2Cl2]) is often present in industrial waste gas and is a valuable chemical product in the chemical industry. This study addresses the oxidation of airstreams that contain CH2Cl2 by catalytic oxidation in a tubular fixed-bed reactor over perovskite-type oxide catalysts. This work also considers how the concentration of influent CH2Cl2 (Co = 500-1000 ppm), the space velocity (GHSV = 5000-48,000 1/hr), the relative humidity (RH = 10-70%) and the concentration of oxygen (O2 = 5-21%) influence the operational stability and capacity for the removal of CH2Cl2. The surface area of lanthanum (La)-cobalt (Co) composite catalyst was the greatest of the five perovskite-type catalysts prepared in various composites of La, strontium, and Co metal oxides. Approximately 99.5% CH2Cl2 reduction was achieved by the catalytic oxidation over LaCoO3-based perovskite catalyst at 600 degrees C. Furthermore, the effect of the initial concentration and reaction temperature on the removal of CH2Cl2 in the gaseous phase was also monitored. This study also provides information that a higher humidity corresponds to a lower conversion. Carbon dioxide and hydrogen chloride were the two main products of the oxidation process at a relative humidity of 70%.  相似文献   

11.
Patel A  Zhu J  Nakhla G 《Chemosphere》2006,65(7):1103-1112
In this study, the performance of the circulating fluidized bed bioreactor (CFBB) with anoxic and aerobic beds and employing lava rock as a carrier media for the simultaneous removal of carbon, nitrogen and phosphorus from municipal wastewater at an empty bed contact time (EBCT) of 0.82 h was discussed. The CFBB was operated without and with bioparticles' recirculation between the anoxic and aerobic bed for 260 and 110 d respectively. Without particles' recirculation, the CFBB was able to achieve carbon (C), total nitrogen (N) and phosphorous (P) removal efficiencies of 94%, 80% and 65% respectively, whereas with bioparticles' recirculation, 91%, 78% and 85% removals of C, N and P were achieved. The CFBB was operated at long sludge retention time (SRT) of 45-50 d, and achieved a sludge yield of 0.12-0.135 g VSS g COD(-1). A dynamic stress study of the CFBB was carried out at varying feed flow rates and influent ammonia concentrations to determine response to shock loadings. The CFBB responded favourably in terms of TSS and COD removal to quadrupling of the feed flow rate. However, nitrification was more sensitive to hydraulic shock loadings than to doubling of influent nitrogen loading.  相似文献   

12.
One of the main challenges that face successful biofiltration is the erratic loading pattern and long starvation periods. However, such patterns are common in practical applications. In order to provide long-term stable operation of a biofilter under these conditions, a cyclic adsorption/desorption beds system with flow switching was installed prior to a biofilter. Different square waves of a mixture containing n-hexane and benzene at a 2:1 ratio were applied to the cyclic adsorption/desorption beds and then fed to a biofilter. The performance of this integrated system was compared to a biofilter unit receiving the same feed of both VOCs. The cyclic adsorption/desorption beds unit successfully achieved its goal of stabilizing erratic loading even with very sharp peaks at the influent concentration equalizing influent concentrations ranging from 10-470 ppmv for n-hexane to 30-1410 ppmv for benzene. The study included different peak concentrations with durations ranging from 6 to 20 min. The cyclic beds buffered the fluctuating influent load and the followed biofilter had all the time a continuous stable flow. Another advantage achieved by the cyclic adsorption/desorption beds was the uninterrupted feed to the biofilter even during the starvation where there was no influent in the feed. The results of the integrated system with regard to removal efficiency and kinetics are comparable to published results with continuous feed studies at the same loading rates. The removal efficiency for benzene had a minimum of 85% while for n-hexane ranged from 50% to 77% according to the loading rate. The control unit showed very erratic performance highlighting the benefit of the utilization of the cyclic adsorption/desorption beds. The biofilter was more adaptable to concentration changes in benzene than n-hexane.  相似文献   

13.
好氧硝化颗粒污泥膜生物反应器性能和膜污染研究   总被引:4,自引:3,他引:1  
实验研究了好氧硝化颗粒污泥膜生物反应器AGMBR的处理性能,并将其与活性污泥膜生物反应器ASMBR进行对比,考察了颗粒污泥在减缓膜污染中所起的作用.好氧硝化颗粒污泥膜生物反应器AGMBR连续稳定运行102 d,系统具有良好的去除有机物和同时硝化反硝化能力,在进水COD和NH+4-N浓度分别为500和200 mg/L时,COD、NH+4-N和TN的去除率分别稳定在86%、94%和45%以上.颗粒污泥有效减缓了膜污染,延长了膜清洗的周期,AGMBR中的膜污染以膜孔堵塞为主,占总阻力的64.81%;滤饼层的阻力为2.1×1012m-1,远小于ASMBR中的16.07×10"m-1;膜清洗周期是相同条件下ASMBR的2.43倍以上;而且AGMBR内不断有新颗粒生成,维持了AGMBR系统性能和运行的稳定.  相似文献   

14.
This paper reports results of studies using a biotrickling filter with blast-furnace slag packings (sizes = 2-4 cm and specific surface area = 120 m2/m3) for treatment of ethylether in air stream. Effects of volumetric loading, superficial gas velocity, empty bed gas retention time, recirculation liquid flow rate, and biofilm renewal on the ethylether removal efficiency and elimination capacity were tested. Results indicate that ethylether removal efficieincies of more than 95% were obtained with an empty bed retention time (EBRT) of 113 sec and loadings of lower than 70 g/m3/hr. At an EBRT of 57 sec, removal efficiencies of more than 90% could only be obtained with loadings of lower than 35 g/m3/hr. The maximum elimination capacities were 71 and 45 g/m3/hr for EBRT = 113 and 57 sec, respectively. The maximum ethylether elimination capacities were 71 and 96 g/m3/hr, respectively, before and after the renewal at EBRT = 113 sec. With an EBRT of 113 sec and a loading of lower than 38 g/m3/hr, the removal efficiency was nearly independent of the superficial liquid recirculation velocity in the range of 3.6 to 9.6 m3/m2/hr. From data regression, simplified masstransfer limited, and reaction- and mass-transfer limited models correlating the contaminant concentration and the packing height were proposed and verified. The former model is applicable for cases of low influent contaminant concentrations or loadings, and the latter is applicable for cases of higher ones. Finally, CO2 conversion efficiencies of approximately 90% for the influent ethylether were obtained. The value is comparable to data reported from other related studies.  相似文献   

15.
Chowdhury N  Nakhla G  Zhu J 《Chemosphere》2008,71(5):807-815
A novel liquid-solid circulating fluidized bed bioreactor (LSCFB) configured with anoxic and aerobic columns and lava rock as the biofilm carrier was used to treat synthetic municipal wastewater. Four different empty bed contact times (EBCTs) of 0.82, 0.65, 0.55, and 0.44 h were examined to optimize nutrient removal capability of the system. The LSCFB demonstrated tertiary effluent quality organic and nitrogen removal efficiencies. Effluent characteristics of the LSCFB were soluble biological oxygen demand (SBOD)10 mg l(-1) and total nitrogen (TN)<10 mg l(-1) at organic loading rate (OLR) of 5.3 kg m(-3)d(-1) and nitrogen loading rate of 0.54 kg Nm(-3)d(-1). Remarkably low yields of 0.14, 0.17, 0.19, and 0.21 g VSS g(-1)COD were observed at OLR of 2.6, 3.2, 4.1 and 5.3 kg COD m(-3)d(-1), where increment of biomass growth and detachment rate were also experienced with increasing OLR. However the system demonstrated only 30% phosphorus removal, and mass balances along the anoxic and aerobic columns showed biological phosphorus removal in the system. Organic mass balance showed that approximately 40% of the influent COD was utilized in the anoxic column and the remaining COD was oxidized in the aerobic column. The system is very efficient in nitrification-denitrification, with more than 90% nitrification of ammonium and overall nitrogen removal in the LSCFB was 70+/-11% even at an EBCT of 0.44 h.  相似文献   

16.
高强度好氧反应器(jet-loop compact reactor,JLCR)采用射流曝气强制溶氧.对JLCR处理制药废水进行了试验研究,考察了JLCR的运行效果、反应器的启动与污泥驯化、抗冲击负荷性能以及污泥沉降性能等.初步结果表明,该系统启动时间较短,运行稳定,COD去除效果较好.进水COD为8000 mg/L左右时,去除率达到80%.  相似文献   

17.
ABSTRACT

This paper presents results obtained from a performance study on the biotreatment of 1,3-butadiene in an air stream using a reactor that consisted of a two-stage, in-series biotrickling filter connected with a three-stage, in-series biofilter. Slags and pig manure-based media were used as packing materials for the biotrickling filter and the biofilter, respectively. Experimental results indicated that, for the biotrickling filter portion, the butadiene elimination capacities were below 5 g/m3/hr for loadings of less than 25 g/m3/hr, and the butadiene removal efficiency was only around 17%. For the biofilter portion, the elimination capacities ranged from 10 to 107 g/m3/hr for loadings of less than 148 g/m3/hr. The average butadiene removal efficiency was 75–84% for superficial gas velocities of 53–142 m/hr and a loading range of 10–120 g/m3/hr. The elimination capacity approached a maximum of 108 g/m3/hr for a loading of 150 g/m3/hr. The elimination rates of butadiene in both the biotrickling filter and biofilter were mass-transfer controlled for influent butadiene concentrations below about 600 ppm for superficial gas velocities of 29–142 m/hr. The elimination capacity was significantly higher in the biofilter than in the biotrickling filter. This discrepancy may be attributed to the higher mass-transfer coefficient and gas-solid interfacial area offered for transferring the gaseous butadiene in the biofilter.  相似文献   

18.
Chang CT  Chen BY  Shiu IS  Jeng FT 《Chemosphere》2004,55(5):751-756
The study provides novel attempt to use an aerobic biofiltration system containing entrapped mixed microbial cells (EMMC) for removal of (CH3)3N-dominant waste gases. In the study, heterotrophic microflora-immobilized cellulose was packed into an EMMC reactor to degrade (CH3)3N. Effects of (CH3)3N inlet concentrations in continuous mode of operation at various flow rates are indicated. The result indicated that the (CH3)3N removal efficiency is higher than 90% at inlet loading below 27.2 mgNh(-1) and retention time 5.3 min. In addition, the maximal mass loading to reach approximately 99% efficiency was 95.5 mgNh(-1) for trimethylamine treatment. This EMMC biofiltration system also showed higher tolerance to endure fluctuations in concentrations and flow rates and still maintained in stable performance for removal. Adaptability test in response to gradual shift up and down of inlet TMA loading indicated that lack of steady-state multiplicity and hysteresis guarantees the microbial communities more precisely adapted to continuous treatment for maintaining stability.  相似文献   

19.
Bajaj M  Gallert C  Winter J 《Chemosphere》2008,73(5):705-710
In this study the continuous treatment of 2-chlorophenol (2-CP) containing synthetic wastewater at increasing concentrations up to 2600 mg L-1 in an anaerobic fixed bed reactor was achieved. As a source of microorganisms municipal sewage sludge was acclimatised to maximally 50 mg L-1 2-CP by 3 successive feedings within 1.5 months. Then, an anaerobic fixed bed reactor was inoculated with this sludge and was operated for 318 d, during which the 2-CP influent concentration was stepwise increased from 50 to 2600 mg L-1 within 265 d. At a hydraulic retention time (HRT) of 2.2 d the 2-CP loading rate was 2 g L-1 d-1 and the average 2-CP removal rate was 0.87 g L-1 d-1, accounting for 73% removal. This is the highest 2-CP removal rate ever reported. The negative effect of a 2-CP loading rate of 1.36 g L-1 d-1 on 2-CP removal was reversible within 2 wk when lower loading conditions (e.g. 0.76 g 2-CP L-1 d-1) were re-established. The median chloride ion release per unit 2-CP degraded was 0.24, which was reasonably close to the theoretically expected value of 0.28. In a batch assay, carried out with relatively clear reactor effluent, the highest removal rate of 2-CP was 175 mg L-1 d-1. At the time of reactor termination on day 318, the 2-CP removal rate by the biofilm in the reactor was 0.61 g L-1 d-1, corresponding to a HRT of 3.4 d and a 2-CP loading rate of 0.76 g L-1 d-1. At these very stable conditions removal of COD was 84% and of 2-CP 81%  相似文献   

20.
Out of an array of bacterial strains isolated from soil contaminated with effluents from electroplating wastewater, Bacillus coagulans exhibited the maximum Cr(VI) reduction potential. The feasibility of an immobilized B. coagulans bioreactor for hexavalent chromium reduction was investigated. Experimental results demonstrated that near complete removal of Cr(VI) was achieved in the reactor with an initial Cr(VI) concentration of 26 mg/l and reactor time of 24 h. The removal efficiency in the bioreactor was significantly affected by the influent Cr(VI) concentration, the Cr(VI) loading rate, the reaction time and the amount of Cr(VI) reduced by the biomass.  相似文献   