首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Recently, we measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in soil and herbage samples collected in the vicinity of a municipal solid waste incinerator (MSWI) from Tarragona (Catalonia, Spain). Since these concentrations could be increased by the presence of other emission sources of PCDD/Fs in the same area in which the MSWI is placed, the main goal of the present study was to determine the PCDD/F congener profiles in the soil and vegetation samples collected in 1996 and again in 1997 near to the facility and to compare with those from samples collected in a close area outside of direct emissions of the plant. From an accurate inspection of the PCDD/F congener profiles, it was concluded that PCDD/F emissions from the MSWI here examined are neither the only nor the main responsible for the presence of PCDD/Fs in the samples of environmental matrices collected in the area under direct influence of the plant.  相似文献   

2.
Levels of dioxins and furans in urban surface soil in Trondheim, Norway   总被引:1,自引:0,他引:1  
A study was conducted on polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in surface soil in order to determine the concentration levels and possibly distinguishing between known and potential sources. The concentration levels are low (0.16-14 ng I-TEQ kg(-1)). The results show a clear pattern where the highest concentration levels were found in the oldest parts of the city. A number of sources were recognised in the soil samples through congener profiles, not all of them active, although similar congener profiles make it extremely difficult to distinguish between different sources. Estimations show that the municipal solid waste incinerator (MSWI) and domestic wood burning are the largest PCDD/F pollution sources within the area.  相似文献   

3.
In 2005 and 2006, the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs) and metals (As, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sn, Tl and V) were measured in air samples collected in an industrial area of Sant Adrià del Besòs (Barcelona, Catalonia, Spain) where a municipal solid waste incinerator (MSWI) is placed, and in a background/control area. In general terms, concentrations of all environmental pollutants were higher at the industrial site. No significant seasonal/temporal variations were observed in any of the areas. No Pearson correlation was found between the PCDD/F concentrations and the environmental conditions of the two sampling periods considered. Principal component analyses (PCA) were performed to get information on the relationship among samples, pollutants, and emission sources. The results indicate that the MSWI of S. Adrià de Besòs is not a significant emission source of the above compounds for the area under its direct influence. Moreover, a notable difference in the PCDD/F congener profiles was found between ambient air and stack gas emissions, indicating that the current levels of PCDD/Fs are more related to other potential emissions sources rather than to those from the MSWI.  相似文献   

4.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

5.
Xu MX  Yan JH  Lu SY  Li XD  Chen T  Ni MJ  Dai HF  Cen KF 《Chemosphere》2008,71(6):1144-1155
Isomer-specific data were investigated in order to identify the sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in agricultural soils, including Fluvo-aquic and paddy soils, in the vicinity of a Chinese municipal solid waste incineration (MSWI) plant. Homologue and isomer profiles of PCDD/Fs in soils were compared with those of potential sources, including combustion sources, i.e., MSWI flue gas and fly ash; and the impurities in agrochemicals, such as the pentachlorophenol (PCP), sodium pentachlorophenate (PCP-Na) and 1,3,5-trichloro-2-(4-nitrophenoxy) benzene (CNP). The results showed that the PCDD/F isomer profiles of combustion sources and agricultural soils were very similar, especially for PCDFs, although their homologue profiles varied, indicating that all the isomers within each homologue behave identically in the air and soil. Moreover, factor analysis of the isomer compositions among 33 soil samples revealed that the contamination of PCDD/Fs in agricultural soils near the MSWI plant were primarily influenced by the combustion sources, followed by the PCP/PCP-Na and CNP sources. This implication is consistent with our previous findings based on chemometric analysis of homologue profiles of soil and flue gas samples, and identifies PCP/PCP-Na as an additional important source of PCDD/Fs in the local area. This makes the similarities and differences of isomer profiles between Fluvo-aquic and paddy soils more explainable. It is, therefore, advisable to use isomer-specific data for PCDD/F source identifications where possible.  相似文献   

6.
Cheng PS  Hsu MS  Ma E  Chou U  Ling YC 《Chemosphere》2003,52(9):1389-1396
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in twenty-one ambient air samples, eight soil samples and two stack gas samples, collected near or in a municipal solid waste incinerator (MSWI) in Hsinchu, Taiwan. A systematic decrease of PCDD/Fs in the ambient air from the northeastern area was observed. PCDD/Fs levels measured in the ambient air range from 0.058 to 0.127 pg-TEQ/m3. Higher PCDD/Fs levels in the ambient air were found during winter. In addition, PCDD/Fs levels measured in the soil range from 0.524 to 5.02 pg-TEQ/g d.m. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) did not provide sufficient evidence that the environmental PCDD/Fs contamination was caused by emissions from the Hsinchu MSWI. An unknown PCDD/Fs source was proposed using congener profile analysis and supported by both PCA and HCA.  相似文献   

7.
Congener profiles are the fractional distribution of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) congeners in an environmental release, or in an environmental or biological sample. In 1999, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an old municipal solid waste incinerator (MSWI) from Montcada (Barcelona, Spain). The main goal of the present study was to determine if the environmental PCDD/F levels in the area under direct influence of the facility were mainly due to PCDD/F emissions from the plant. For this purpose, soil and herbage samples were collected near the MSWI before (1998) and after (2000) the technical improvements were performed. PCDD/F congener profiles were determined and compared with those from samples collected in a suburban area of Constantí (Tarragona, Spain) outside of direct emissions from any MSWI. The results of the present study suggest that the MSWI here assessed is not the main responsible for the environmental PCDD/F concentrations in the area under evaluation. Other PCDD/F emission sources in the same area seem also to have a notable impact on the atmospheric levels of these pollutants.  相似文献   

8.
Emission of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) by municipal solid waste incinerators (MSWI) is an issue of great concern. In 1997, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an MSWI from Tarragona (Catalonia, Spain). As a result, PCDD/F emissions were significantly reduced. The aim of this study was to determine the current levels of PCDD/Fs in soil and vegetation samples collected near the facility and to compare these levels with those obtained in previous surveys (1996 and 1997). In the period 1997-1999, PCDD/F concentrations in vegetation samples were significantly decreased (60%). By contrast, the levels of PCDD/Fs in soil samples increased slightly (14%, P > 0.05) during the same period. An exhaustive analysis of the present data indicates that other emission sources of PCDD/Fs have also a notable environmental impact on the area under direct influence of the MSWI.  相似文献   

9.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

10.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

11.
Levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in both air and soil samples were measured at three different sites in Italy, in proximity to three municipal solid waste incinerators (MSWIs) to determine baseline contamination and the contributory role of incinerator emissions. At the first site, located in an agricultural, cattle-breeding, typically flattish area of the Po Valley, the dioxin concentrations had already been measured before the start-up of the new MSWI. These dioxin concentrations were then again measured after two years of continual operation of the incinerator. Despite the presence of the plant, the PCDD/Fs concentrations appear not to have been affected and were found to be in a range of 22-125 fg I-TEQ m(-3) in the air samples and 0.7-1.5 pg I-TEQ g(-1) in the soil samples. The second site is located in an industrial district of the Veneto Region, in the surroundings of an old MSWI that is not equipped with Best Available Technology (BAT) dioxin removal system. The PCDD/Fs concentrations in the air samples were between 144 and 337 fg I-TEQ m(-3). This is a typical range of values for industrial areas, while the soil samples showed contamination levels between 1.1 and 1.4 pg I-TEQ g(-1). The third site lies in the Adige Valley, near a MSWI that has been equipped with BAT for flue gas cleaning. The observed values ranged from 10 to 67 fg I-TEQ m(-3) for the air samples and 0.08-1.2 pg I-TEQ g(-1) for the soil samples. The contributory factors of the varying characteristics of the different areas together with the types of technology adopted at each MSWI plant are discussed. The PCDD/Fs levels are subsequently compared with established values from previous studies.  相似文献   

12.
The stack gases of a municipal solid waste incinerator (MSWI), and ambient air were sampled in four locations around the plant for the analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs). The sampling area was close to an industrial area near Trieste, in north-east Italy. The purpose of the study was to estimate the impact of the MSWI emissions and to distinguish the contribution of these emissions from other potential emission sources in the industrial area.PCDD/F atmospheric concentrations were similar to those generally detected in urban–rural areas with one location about 2–3 times more contaminated than the others. Since the most contaminated location was inside the industrial area but upwind of the MSWI, principal component analysis (PCA) was used to establish whether other sources were the cause. This analysis clearly showed that a local steel plant’s emission was the main source of PCDDs/Fs in ambient air. This study highlights the usefulness of multivariate data analysis such as PCA to identify, among different potential emission sources, the one really responsible for the contamination.  相似文献   

13.
Kim BH  Lee SJ  Mun SJ  Chang YS 《Chemosphere》2005,58(11):1589-1599
Many studies have been conducted that monitor and trace the sources of polychlorinated dibenzo-p-dioxin/furans (PCDD/Fs) by comparing congener patterns of environmental samples with those of possible sources. In this study, we measured PCDD/F concentrations and compared congener patterns of samples of various media found in and around an industrial waste incinerator in Korea, including stack gas, fly ash, bottom ash, ambient air, soil, pine needle, and human blood. We obtained reliable data on the relationship between the PCDD/F distributions in these sources and the environment, and thus found indicators with which to assess the impact of such sources on the surrounding environment. In addition, the difference between the levels of PCDD/Fs in the blood of short-term workers and long-term workers demonstrates that these workers are exposed to the compounds produced by the indicator.  相似文献   

14.
Lin LF  Lee WJ  Li HW  Wang MS  Chang-Chien GP 《Chemosphere》2007,68(9):1642-1649
The objectives of the present study were to quantify (1) the emission factors of a variety of dioxin emission sources; (2) the overall dioxin emission inventory in Taiwan as well as in a major metropolitan (KC area); and (3) the contribution of power plants to the overall PCDD/F emission. To achieve these goals, a total of 95 flue gas samples were collected and analyzed for 17 PCDD/Fs from 20 sources to develop emission factors. The emission factor of PCDD/Fs from coal-fired power plants (0.62 microgI-TEQton(-1)) obtained in this study is considerably higher than the values reported from different countries including UK, USA, and Spain by a factor of 2-265. It means that the air pollution control devices in certain power plants need to be more efficient. The emission data showed that there is a total annual release to air of 6.1 and 95gI-TEQ from major sources in the KC area and Taiwan, respectively. The dominant sources of PCDD/Fs in the KC area are the coal-fired power plants, secondary aluminum smelting, electric arc furnaces, and open burning of rice straw, which contributed for 56%, 17%, 13%, and 3.3% to the total, respectively. However, in Taiwan, the dominant sources of PCDD/Fs are the iron ore sintering, coal-fired power plants, electric arc furnaces, and open burning of rice straw, which contributed for 32%, 28%, 23%, and 8.1% to the total, respectively. The results of this study showed that coal-fired power plants are very significant sources of PCDD/Fs and also provide an important database to assist the decision makers for formulating policies to alleviate dioxin concerns.  相似文献   

15.
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) were analyzed in samples of the emissions from a secondary aluminum smelter (ALS) and soil samples around the plant. The purpose was to estimate the impact of the emissions on the surrounding environment.PCDD/F soil concentrations were higher in the proximity of the plant, exceeding the limit adopted in Italy in soils for green areas and residential uses and the upper limit of several reference concentrations. The most contaminated sites were less than 500 m from the plant and the dioxin concentration with the distance from the ALS.Principal component analysis (PCA) showed that emissions from the ALS were the source of PCDD/F contamination in the soils closest to the plant. Multivariate data analyses such as PCA are therefore useful to identify sources of emission causing contamination.  相似文献   

16.
《Chemosphere》2012,86(11):1719-1724
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) were analyzed in samples of the emissions from a secondary aluminum smelter (ALS) and soil samples around the plant. The purpose was to estimate the impact of the emissions on the surrounding environment.PCDD/F soil concentrations were higher in the proximity of the plant, exceeding the limit adopted in Italy in soils for green areas and residential uses and the upper limit of several reference concentrations. The most contaminated sites were less than 500 m from the plant and the dioxin concentration with the distance from the ALS.Principal component analysis (PCA) showed that emissions from the ALS were the source of PCDD/F contamination in the soils closest to the plant. Multivariate data analyses such as PCA are therefore useful to identify sources of emission causing contamination.  相似文献   

17.
This study was designed to evaluate soil and air (gas and particle) transfer of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to vegetation in residential and industrial areas. In a first part, soil-vegetation transfer was assessed. The levels of PCDD/Fs in 120 soil and 120 herbage samples collected from 1996 to 2002 in an industrial area of Montcada (Barcelona, Spain), near a municipal solid waste incinerator (MSWI), were determined. Some additional individual samples were also evaluated. It was concluded that high soil concentrations, which are not at steady state with the air layer above it, show a tendency for PCDD/Fs to escape via volatilization. In a second part of the study, air-vegetation transfer was examined. PCDD/F concentrations from 24 herbage samples were used, while PCDD/F concentrations were also measured in seven high-volume air samples and seven passive air-vapor samples. Scavenging coefficients (m3 air "sampled"/g grass d.m.) ranged from 1.9 to 11.3 m3/g. A good trend with K(OA) was observed for PCDDs (R=0.82), while it was lower for PCDFs (R=0.55). The current results corroborate that PCDD/F concentrations in vegetation are associated with atmospheric deposition. For the highest substituted PCDD/F congeners, the air-particle uptake from plants is the principal pathway. In regions impacted by combustion emission sources, PCDD/F gas-particle partitioning is influenced by a higher concentration of particles in the air. Particles and associated particle-bound PCDD/Fs would sorb to leaf surfaces, and are subject to removal via wash off. However, in areas where emissions to air are not very notable, vapor absorption would be the principal source of vegetation pollution. The results of this investigation can have a potential interest in risk assessment studies and environmental fate models.  相似文献   

18.
Kim M  Kim DG  Yun SJ  Son SW 《Chemosphere》2008,70(9):1563-1567
The relationship between profiles of residual PCDD/Fs in beef and raw milk was examined by measuring concentrations and detected frequencies. Unrelated samples of beef and raw milk were collected from nine regions in South Korea. Congener-specific profiles of PCDD/Fs in beef and raw milk were very similar. PCDFs, particularly 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, and 2,3,4,6,7,8-HxCDF, were dominant congeners in both beef and raw milk suggesting that sources of contamination may not significantly differ nationwide. The profiles of PCDD/Fs in domestic beef and raw milk in this study were closer to the profiles of emission from metal industries although Korea imports over 75% of feedingstuffs. The ratios of PCDF/PCDD in TEQ concentration were more than 5 and 15 in beef and raw milk, respectively. The mean concentrations of PCDD/Fs in 60 samples of beef and 60 samples of raw milk were 0.80 pg WHO-TEQ/g fat and 0.65 pg WHO-TEQ/g fat, respectively. The residual profiles of PCDD/Fs in raw milk resembled that in beef although the congener profiles might change throughout the food chain. This indicated that monitoring of dioxins in milk could provide information for contamination of milk itself or other associated food.  相似文献   

19.
20.
Biomonitoring of dioxin body burden, as evaluated by PCDD/F levels in blood, has been carried out in a total of 138 adults from general population living in the vicinity of solid waste incinerators in Portugal. Measurements were performed included in cross-sectional surveys within two Environmental Health Surveillance Programs launched in response to ecotoxicological concern in relation to solid waste incinerators near Lisbon and in Madeira Island. Overall conclusion from first published results is indicative that dioxin exposure of global populations cannot be related to the emissions of these facilities, meaning that dioxin sources control seems to be effective in relation to both incinerators. Main objective of present work was to investigate potential determinants of dioxin levels in the studied populations. Findings from this investigation also suggest that incineration does not impact on dioxin blood levels of nearby residents. Follow-up of a small group of individuals (22) from Lisbon gives preliminary indication on temporal control effectiveness of the Lisbon facility. Regarding comparison between PCDD/F levels from Lisbon and Madeira communities, individuals from Lisbon show higher median PCDD/F levels, likely to be better explained by more highly polluted areas in Lisbon than by eventual differences in dietary habits of the studied groups. In fact, analysis performed on the diet of both groups (not detailed in the present study) does not show a statistically significant difference in relation to any of the most relevant foodstuffs in the context of dioxin exposure. Comparison between Lisbon and Madeira in relation to pattern of the single congeners for PCDD/Fs shows a very similar profile. The highest contributions to the PCDD/Fs toxicity came from 12378-PCDD, 23478-PCDF, Hexa-CDD, 2378-TCDD and Hexa-CDF.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号