首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A HPLC-MS/MS method is presented for the simultaneous determination of frequently used artificial sweeteners (ASs) and the main metabolite of aspartame (ASP), diketopiperazine (DKP), in environmental water samples using the direct-injection (DI) technique, thereby achieving limits of quantification (LOQ) of 10 ng L−1. For a reliable quantification of ASP pH should be adjusted to 4.3 to prevent formation of the metabolite. Acesulfame (ACE), saccharin (SAC), cyclamate (CYC) and sucralose (SUC) were ubiquitously found in water samples. Highest concentrations up to 61 μg L−1 of ACE were found in wastewater effluents, followed by surface water with concentrations up to 7 μg L−1, lakes up to 600 ng L−1 and groundwater and tap water up to 70 ng L−1. The metabolite DKP was only detected in wastewater up to 200 ng L−1 and at low detection frequencies.  相似文献   

2.
Tian H 《Chemosphere》2011,83(3):349-355
A sensitive method for determination of chloramphenicol, enrofloxacin and 29 pesticides residues in bovine milk by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. Residues of the targets were extracted from milk with acetonitrile, cleaned up by C18-SPE cartridge, and then determined by HPLC-MS/MS. The MS detection was operated in positive or negative ionization mode, depending on the compounds. For confirmation of each target compound, two precursor ion > product ion transitions were selected by multi-reaction monitoring mode (MRM). The method showed good linearity for all the tested compounds over the studied concentration range with correlation coefficient higher than 0.9910. Recoveries for the studied compounds at three spiked levels (0.05, 0.10, 0.19 mg kg−1) in bovine milk were in the range of 71-107% with RSDs not larger than 13.7%, except that recoveries of trifluralin ranged between 62% and 70% at the spiked levels. Limits of quantitation for the analytes were estimated to range between 0.03 × 10−3 and 14.5 × 10−3 mg kg−1. The proposed method was applied for the determination of the analytes residues in real samples. The found levels of the analytes in milk samples were lower than maximum residues levels (MRL).  相似文献   

3.
A multiresidue method for the analysis of 86 persistent pollutants in marine sediments at ultra-trace level has been developed and validated using pressurized liquid extraction (PLE) and stir-bar sorptive extraction (SBSE) coupled with thermal desorption and gas chromatography-triple quadrupole mass spectrometry (TD-GC-MS/MS QqQ). The compounds analyzed belong to various families such as polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polybrominated diphenylethers, organophosphorus and organochlorine pesticides and other pesticides such as urons, and triazines. The analytes have very different polarities and log Kow values, which is an important parameter in the optimization of a SBSE method. Due to PLE high efficiency and throughput rates, along with the proven ability for multiresidue analysis and excellent sensitivity of SBSE, we present an efficient method. The limits of quantification obtained ranged from 0.014 to 1.0 ng g−1, with detection limits below pg g−1 levels. In order to validate the proposed methodology, quality parameters such as recovery, linearity and reproducibility were studied. Recoveries ranged from 63% to 119%, reproducibility (in terms of Relative Standard Deviation for ten determinations) was lower than 35% in all cases, and determination coefficients higher than 0.990 for all analytes. The main factors that affect PLE, SBSE and GC-MS/MS procedures were optimized. The method was applied to the analysis of nine marine sediments obtained from the nine main submarine wastewater discharge points (emissaries) presents along the coast of Tenerife Island (Canary Islands, Spain).  相似文献   

4.
A new approach for the identification of suspect trace organic contaminants in drinking and surface waters is presented. Samples were initially analyzed using a target determination method for two contamination tracers, carbamazepine (CBZ) and atrazine (ATZ). This method used offline solid-phase extraction and online solid-phase extraction techniques coupled to liquid chromatography-triple quadrupole mass spectrometry to accelerate the sample preparation process and improve method performance. CBZ and ATZ were found respectively in 31% and 56% of the samples, and concentrations were usually <20 ng L−1. These samples were re-analyzed with a similar method on a quadrupole time-of-flight mass spectrometer to identify suspect contaminants by means of exact mass measurements and isotope patterns. A database of 264 common organic contaminants was built and used in conjunction with a Molecular Feature algorithm to identify the presence of these substances in drinking and surface water collected from different sources at various locations across Canada. Several organic contaminants were identified in the samples, but only the presence of caffeine, desethylatrazine, simazine and venlafaxine could be verified by comparison to pure standards. The presence of desethylatrazine was also confirmed by MS/MS experiments. These results suggest that target analysis for tracers of organic contamination may be a helpful tool to prioritize samples which should be further screened for suspect contaminants. This study also shows that the combination of separation techniques (offline and online SPE, LC) contribute to advance the applicability of high-resolution mass spectrometry for the identification of trace organic contaminants by accelerating the preparation step, reducing complexity and increasing analyte concentrations for optimal detection.  相似文献   

5.
A new sample treatment method for the determination of four common booster biocides (Diuron, TCMTB, Irgarol 1051 and Dichlofluanid) in harbour sediment samples has been developed that uses liquid chromatography-tandem mass spectrometry (LC-MS/MS) after microwave-assisted extraction, followed by clean-up and a solid phase extraction preconcentration step (MAE-SPE). The effects of different variables on MAE-SPE were studied. The recoveries obtained were greater than 75%, and the relative standard deviation was less than 7%. The detection limits ranged between 0.1 and 0.3 ng g−1. The developed methodology was successfully applied to the evaluation of the presence of booster biocides in sediment samples from different harbours and marinas of Gran Canaria Island (Canary Islands, Spain).  相似文献   

6.
The disposal and dumping of toxic waste is a matter of growing concern in developing countries, including South Africa. Frequently these countries do not possess access to gas chromatography-high resolution mass spectrometry (GC-HRMS) for the determination of persistent organic pollutants (POPs). This publication describes an alternative approach to the investigation of toxic waste using comprehensive gas chromatography coupled to time of flight mass spectrometry (GC × GC-TOFMS). The technology permits both comprehensive screening of toxic samples for numerous classes of organic pollutants and also quantitative analysis for the individual compounds. This paper describes the use of this technique by analysing samples obtained from a hazardous waste treatment facility in South Africa. After sampling and extraction the samples were analysed for polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and four dioxin-like non-ortho substituted polychlorinated biphenyls (PCBs). The quantitative values, as well as detection limits, obtained using the GC × GC-TOFMS methodology compares well with those obtained using GC-HRMS; the accepted benchmark technology for this analysis. Although GC × GC-TOFMS is not a target compound analytical technique (as is GC-HRMS), it is possible to obtain information on numerous other classes of organic pollutants present in the samples in one analytical run. This is not possible with GC-HRMS. Several different column combinations have been investigated for handling very complex waste samples and suggestions are presented for the most suitable combination.  相似文献   

7.
The content of total arsenic and arsenic compounds in the dominant seaweed species in the Thermaikos Gulf, Northern Aegean Sea was determined in samples collected in different seasons. Total arsenic was determined by acid digestion followed by ICP–MS. Arsenic speciation was analyzed by water extraction followed by LC–ICP–MS. Total arsenic concentrations in the seaweeds ranged from 1.39 to 55.0 mg kg−1. Cystoseira species and Codium fragile showed the highest total As contents, while Ulva species (U. intestinalis, U. rigida,U. fasciata) had the lowest Arsenosugars, the most common arsenic species in seaweeds, were found in all samples, and glycerol-arsenosugar was the most common form; however, phosphate-arsenosugar and sulfate-arsenosugar were also present. Inorganic arsenic was measured in seven algae species and detected in another. Arsenate was the most abundant species in Cystoseira barbata (27.0 mg kg−1). Arsenobetaine was measured in only one sample. Methylated arsenic species were measured at very low concentrations. The information should contribute to further understanding the presence of arsenic compounds in dominant seaweeds from the Thermaikos Gulf.  相似文献   

8.
A multiresidue analytical method was developed for the determination of 9 endocrine disrupting chemicals (EDCs) and 19 pharmaceuticals and personal care products (PPCPs) including acidic and neutral pharmaceuticals in water and soil samples using rapid resolution liquid chromatography-tandem mass spectrometry (RRLC-MS/MS). Solid phase extraction (SPE), and ultrasonic extraction combined with silica gel purification were applied as pretreatment methods for water and soil samples, respectively. The extracts of the EDCs and PPCPs in water and soil samples were then analyzed by RRLC-MS/MS in electrospray ionization (ESI) mode in three independent runs. The chromatographic mobile phases consisted of Milli-Q water and acetonitrile for EDCs and neutral pharmaceuticals, and Milli-Q water containing 0.01 % acetic acid (v/v) and acetonitrile: methanol (1:1, v/v) for acidic pharmaceuticals at a flow rate of 0.3 mL/min. Most of the target compounds exhibited signal suppression due to matrix effects. Measures taken to reduce matrix effects included use of isotope-labeled internal standards, and application of matrix-match calibration curves in the RRLC-MS/MS analyses. The limits of quantitation ranged between 0.15 and 14.08 ng/L for water samples and between 0.06 and 10.64 ng/g for solid samples. The recoveries for the target analytes ranged from 62 to 208 % in water samples and 43 to 177 % in solid samples, with majority of the target compounds having recoveries ranging between 70–120 %. Precision, expressed as the relative standard deviation (RSD), was obtained less than 7.6 and 20.5 % for repeatability and reproducibility, respectively. The established method was successfully applied to the water and soil samples from four irrigated plots in Guangzhou. Six compounds namely bisphenol-A, 4-nonylphenol, triclosan, triclocarban, salicylic acid and clofibric acid were detected in the soils.  相似文献   

9.
A rapid analytical screening method allowing simultaneous analysis of 23 persistent organic pollutants (POPs) in human plasma was developed. Sample preparation based on solid-phase extraction (SPE) with additional clean-up using small multilayer silica gel columns. SPE was performed using a custom made polystyrene-divinylbenzene sorbent for the extraction of chlorinated and brominated POPs. Special efforts to reduce sample volume and improve speed and efficiency of the analytical procedure were made. Determination of 16 polychlorinated biphenyls (PCBs), 5 organochlorine (OC) pesticides, octachlorinated dibenzo-p-dioxin (OCDD) and polybrominated diphenyl ether (BDE #47) in 0.5 mL human plasma was performed by using high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC/HRMS). Recovery of POPs ranged between 46% and 110%, and reproducibility was below 25% relative standard deviation (RSD) for all target compounds, except for trans-nonachlor and OCDD, which were present only at low levels. Limits of detection (LOD) were for the PCBs between 0.8 and 117.7 pg mL−1 plasma and for the OC pesticides between 5.9 and 89.1 pg mL−1 plasma. The LOD for OCDD and BDE #47 were 1.4 pg mL−1 plasma, and 9.2 pg mL−1 plasma, respectively. The presented method was successfully applied to 1016 human plasma samples from an epidemiological study on cardiovascular disease.  相似文献   

10.
A method employing solid phase extraction followed by gas chromatography-mass spectrometry with negative chemical ionization has been developed for determination of ultratrace concentrations of perfluoroalkyl carboxylic acids in river water. The effects of the experimental parameters, such as the pH, additions of NaCl and an ion-pairing agent (tetraethylammonium bromide) and the kind of the elution agent, on the efficiency of the test acid extraction have been studied. The analyte extraction recoveries and the limits of detection and determination have been found. The method developed has been tested on determinations of perfluoroalkyl carboxylic acids in the waters of the two largest Czech rivers, Vltava and Labe (Elbe). The best extraction results have been attained without any alteration of the sample pH, with an addition of tetrabutylammonium bromide (a concentration of 50 μg mL−1 in the sample) and using methanol as the elution agent. Under these conditions, the recoveries of the test acids in the spiked real samples are within ranges from 60% to 104% and 53% to 111% for analyte concentration levels of 1.40 ng mL−1 and 0.14 ng mL−1, respectively, depending on the lengths of the perfluorinated chains of the acids. In general, the recovery decreases with increasing length of this chain. The method developed exhibits very low limits of detection and determination and the results are fully comparable with those obtained when using more expensive HPLC-MS/MS instrumentation. Typical values amount to tenths to tens of pg mL−1 and units to one hundred pg mL−1 for the limits of detection and determination, respectively; the measuring sensitivity increases with increasing length of the analyte chain. The analyzes of real samples from the Vltava and Elbe rivers have demonstrated that the results obtained are similar to the values published for contamination of the Elbe and other rivers in western and central Europe. The concentrations determined are of the order of units to tens of pg mL−1 and the C8-C10 acids occur most often.  相似文献   

11.
Myers AL  Mabury SA  Reiner EJ 《Chemosphere》2012,87(9):1063-1069
Mixed halogenated dibenzo-p-dioxins and dibenzofurans (PXDD/PXDFs, X = Br, Cl) are formed through combustion processes, and may be more toxic than their corresponding chlorinated and brominated analogues. With 4600 potential congeners, limited analytical standards, and complex environmental matrices, PXDD/PXDFs present a significant analytical challenge. Gas chromatography tandem mass spectrometry (GC-MS/MS) offers both selectivity and sensitivity through multiple reaction monitoring of unique transitions in a novel approach to PXDD/PXDF congener identification. Method validation was performed through analysis of soil samples obtained from a recycling plant fire. Of the PXDD/PXDFs examined, monobromo-dichlorodibenzofuran was the most prevalent, ranging in concentration from 8.6 ng g−1 to 180 ng g−1. Dibromo-dichlorodibenzo-p-dioxin, a compound of toxicological concern, ranged from 0.41 ng g−1 to 10 ng g−1. Concentrations of PXDD/PXDFs were between 6% and 10% that of the corresponding polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDFs), with the exception of dibromo-dichlorodibenzo-p-dioxin concentrations, which were 36% that of tetrachlorodibenzo-p-dioxins. Higher levels of polybrominated PXDD/PXDFs may indicate a significant bromine source was present during combustion.  相似文献   

12.
Thirty persistent organohalogen compounds including organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), and polybrominated diphenyl ethers (PBDEs) were determined in breast milk samples (n = 36) of primipara and multipara mothers from Bizerte in 2010. The analytical procedure involved the application of liquid-liquid extraction and gas chromatography with electron capture detector (GC-ECD) or mass spectrometry detector (GC-MS) for identification and quantification. Organohalogen compounds were found in all the analyzed samples, with predominance of p,p′-DDE, p,p′-DDT, p,p′-DDD, HCB and PCBs. The mean concentration of ∑DDTs in breast milk was 1163.9 ng g−1 lipid wt. The ratio of p,p′-DDE/p,p′-DDT was low, suggesting that there is fresh intake of commercial DDT products in Bizerte. The mean levels of HCB and PCB were 286.8 and 331.2 ng g−1 lipid wt respectively. These results were compared with the levels obtained in a previous study carried out in the same area in 2003. A general decrease of ∑DDTs levels and an increase of PCB levels were observed. Among the 10 PBDE congeners evaluated, BDE-28, BDE-47, BDE-99, BDE-66, BDE-138, BDE-100, BDE-154, BDE-153, and BDE-183 were detected in the analyzed samples at different frequency. The total PBDE concentrations ranged from 2.5 to 22.6 ng g−1 lipid wt in the samples, with a mean and median value of 10.7 and 9.8 ng g−1 lipid wt respectively. To our knowledge, this is the first data of PBDEs in Tunisian human milk. The present study shows that age and parity are factors influencing the levels of some organohalogen compounds in human milk.  相似文献   

13.
A method for simultaneous quantitative determination of alkyl benzyl, dialkyl and trialkyl quaternary ammonium compounds (QACs) has been developed, validated and subsequently applied to real water samples in Austria. The method employs liquid-liquid extraction (LLE) followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS), using electrospray ionization (ESI) in positive mode. The overall method quantification limits range from 4 to 19ng/L for the enrichment of 500mL water samples and analyte recoveries are between 80 and 99%. The method was applied to 62 of the respective water samples without filtration to avoid the loss of the analytes due to the high adsorption capacity of these compounds. Maxima in the mg/L range, especially in the wastewater of hospitals and laundries, could be detected for the selected target compounds.  相似文献   

14.
Several methods were developed to detect the cyclic volatile methylsiloxanes (cVMSs) including octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5), and dodecamethylcyclohexasiloxane (D6) in water, sediment, soil, biota, and biosolid samples. Analytical techniques employed to optimize measurement of this compound class in various matrices included membrane-assisted solvent extraction in water, liquid–solid extraction for sediment, soil, biota, and biosolid samples. A subsequent analysis of the extract was conducted by large-volume injection–gas chromatography−mass spectrometry (LVI−GC−MS). These methods employed no evaporative techniques to avoid potential losses and contamination of the volatile siloxanes. To compensate for the inability to improve detection limits by concentrating final sample extract volumes we used a LVI–GC–MS. Contamination during analysis was minimized by using a septumless GC configuration to avoid cVMS’s associated with septum bleed. These methods performed well achieving good linearity, low limits of detection, good precision, recovery, and a wide dynamic range. In addition, stability of cVMS in water and sediment was assessed under various storage conditions. D4 and D5 in Type-I (Milli-Q) water stored at 4 °C were stable within 29 d; however, significant depletion of D6 (60–70%) occurred only after 3 d. Whereas cVMS in sewage influent and effluent were stable at 4 °C within 21 d. cVMS in sediment sealed in amber glass jars at −20 °C and in pentane extracts in vials at −15 °C were stable during 1 month under both storage conditions.  相似文献   

15.
Volatile organic compounds (VOCs) from several different municipal solid wastes’ treatment plants in Mallorca (Spain) have been analysed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Ambient (immission) air was collected during February and March 2011 by active sampling onto sorbents Tenax™ TA and Carboxen™ 1000. The study presents the chemical characterisation of 93 volatile organic compounds (VOCs) from an overall set of 84 immission air samples. 70 VOCs were positively identified.The linear fit for all 93 external standard calibration, from 10 mg L−1 to 150 mg L−1 (n = 4), was within the range 0.974 < r2 < 0.998. Limits of detection of the method (LOD) for all the standards were within the range 1.1-4,213 pg, as the absolute standard amount spiked into sorbent tubes in 1 μL standard mixture (dissolved in methanol).Overall results stated systematic correlation between waste’s nature and VOCs’ air composition. Organic wastes show main contribution of terpenes, waste water sludge residues’ of reduced sulphured compounds (RSCs) and municipal solid wastes show contribution of a wide sort of VOCs. The use of a chemometric approach for variable’s reduction to 12 principal components enables evaluation of similarities and dissimilarities between facilities. PCA clearly related samples to its corresponding facility on the basis of their VOCs composition and the ambient temperature.  相似文献   

16.
A simple online headspace solid-phase microextraction (HS-SPME) coupled with the gas chromatography-mass spectrometry (GC-MS) method was developed for simultaneous determination of trace amounts of nine estrogenic odorant alkylphenols and chlorophenols and their derivatives in water samples. The extraction conditions of HS-SPME were optimized including fiber selection, extraction temperature, extraction time, and salt concentration. Results showed that divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber was the most appropriate one among the three selected commercial fibers, and the optimal extraction temperature, time, and salt concentration were 70 °C, 30 min, and 0.25 g/mL, respectively. The developed method was validated and showed good linearity (R 2?>?0.989), low limit of detection (LOD, 0.002–0.5 μg/L), and excellent recoveries (76–126 %) with low relative standard deviation (RSD, 0.7–12.9 %). The developed method was finally applied to two surface water samples and some of these target compounds were detected. All these detected compounds were below their odor thresholds, except for 2,4,6-TCAS and 2,4,6-TBAS wherein their concentrations were near their odor thresholds. However, in the two surface water samples, these detected compounds contributed to a certain amount of estrogenicity, which seemed to suggest that more attention should be paid to the issue of estrogenicity rather than to the odor problem.  相似文献   

17.
A simple method for the determination of dimethyl fumarate (DMFu) in silica gel pouches has been developed. The gas chromatographic behaviour of DMFu was investigated; the instrumental method, based on EI mass spectrometry coupled with an Ion Trap Detector operating whether in full scan mode or in MS/MS mode was also investigated. Several factors have been evaluated and optimized during the development process: solvent and temperature of extraction, type of stationary phase in capillary column. The analytical procedure consists of two steps as follows: (a) the sample preparation using 10 g of sample extracted with acetonitrile in an ultrasonic, heated bath and (b) the determination by gas chromatography-ion trap mass spectrometry. Mass spectrometry in conjunction with chromatographic separation is a very powerful combination for identification of an analyte in the extract in spite of selective detectors employed with GC, such as ECD, FPD and NPD, that offer only limited specificity. Blank samples show no interfering peaks in the areas of interest, so the specificity of the method was assured under the investigated GC/MS conditions. The method has been validated in terms of recovery, repeatability, linearity, detection limits and measurement uncertainty. The results obtained meet both the method validation criteria and requirements of the European/National legislation. The method was verified to be accurate with 97 % mean recoveries at 0.05 mg/kg and 1.00 mg/kg levels; the repeatability (expressed as RSD %) was found to be better than 15 %. Good linearity was found in the range between 0.05 μg/mL and 5.0 μg/mL and a value of R2 > 0.9998 was calculated. The procedure ensures high specificity and a good sensitivity with detection limit (ld) of 0.02 mg/kg and quantification limit (LOQ) of 0.05 mg/kg. This procedure has been successfully applied for the analysis of several hundred of real samples collected during a monitoring control plan started last year in our country. All samples exceeding the maximum allowed level of DMFu (0, 1 mg/kg) were confirmed by GC/MS/MS (ITD) for a higher degree of confidence in identification. The main advantages of this method include: rapidity, simplicity (few, simple steps), reliability, cheapness, no need for long and difficult clean-up and evaporation steps, high specificity by using GC/MS and GC/MS/MS, availability for routine monitoring.  相似文献   

18.
During 2006-2008, a monitoring program was conducted on 29 target compounds, including PCDD/Fs and dl-PCBs, comprising 150 randomly collected individual food samples marketed in the Region of Valencia, Spain, grouped into 8 categories (vegetables, cereals, fats and oils, eggs, milk and dairy products, fish products, meat and meat products and fish oil). For PCDD/Fs, the highest frequency of detection corresponds to 1,2,3,4,6,7,8-HpCDD, OCDD, 2,3,4,7,8-PeCDF; and PCBs 118, 105 and 156 were the more frequent dl-PCBs. The food groups presenting higher contamination, expressed as toxic equivalents (WHO-TEQs), were fish oil (6.38 pg WHO-TEQ g−1 fat), fish (1.21 pg WHO-TEQ g−1 w.w.) and milk and dairy products (0.90 pg WHO-TEQ g−1 fat). Of all analysed samples, only two fish oils presented levels higher than the EU limits for total WHO-TEQ. The average PCDD/Fs and dl-PCBs intakes were estimated as 2.86 pg WHO-TEQ kg−1 b.w. d−1 and 4.58 pg WHO-TEQ kg−1 b.w. d−1, for adults and children, respectively, using the deterministic method for chronic exposure. The main contributors to total intake for adults were fish (59%), milk and dairy products (19%), and fat and oils (9%). The average daily intake for adults (2.86 pg WHO-TEQ kg−1 b.w. d−1) is within range of TDI recommended by the WHO (1-4 pg WHO-TEQ kg−1 b.w. d−1), and slightly above the TWI and PTMI adopted by SCF and JECFA respectively.  相似文献   

19.
Chlorpyrifos is the most common organophosphate insecticide registered for use in Vietnam and is widely used in agriculture, particularly rice farming. However, chlorpyrifos exposure to and adverse effects on farmers has not been evaluated. In this study, biological monitoring of chlorpyrifos exposure in a group of rice farmers was conducted after a typical application event using back-pack spraying.Urine samples (24 h) were collected from the rice farmers before and post insecticide application. Samples were analysed for 3,5,6-trichloropyridinol (TCP), the major urinary metabolite of chlorpyrifos, using an enzymatic pre-treatment before extraction followed by HPLC-MS/MS. Absorbed Daily Dose (ADD) of chlorpyrifos for farmers were then estimated from urinary TCP levels, expressed as μg g−1 creatinine. The analytical method for urinary TCP had a low detection limit (0.6 μg L−1), acceptable recovery values (80-114%), and low relative percentage differences in duplicate and repeated samples.Post-application chlorpyrifos ADD of farmers varied from 0.4 to 94.2 μg kg−1 (body weight) d−1 with a mean of 19.4 μg kg−1 d−1 which was approximately 80-fold higher than the mean baseline exposure level (0.24 μg kg−1 d−1). Hazard Quotients (ratio of the mean ADD for rice farmers to acute oral reference dose) calculated using acute oral reference doses recommended by United States and Australian agencies varied from 2.1 (Australian NRA), 4.2 (US EPA) to 6.9 (ATSDR).Biological monitoring using HPLC-MS/MS analysis of urinary TCP (24 h) was found to be an effective method for measuring chlorpyrifos exposure among farmers. This case study found that Vietnamese rice farmers had relatively high exposures to chlorpyrifos after application, which were likely to have adverse health effects.  相似文献   

20.
Geens T  Neels H  Covaci A 《Chemosphere》2012,87(7):796-802
In this study, an analytical method was optimized for the determination of bisphenol-A (BPA), triclosan (TCS) and 4-n-nonylphenol (4n-NP), environmental contaminants with potential endocrine disruptive activities, in human tissues. The method consisted of a liquid extraction step, derivatization with pentafluorobenzoylchloride followed by a clean-up on acidified silica and detection with gas chromatography coupled with mass spectrometry (GC-ECNI/MS). Recoveries ranged between 92% and 102% with a precision below 5%. Limits of quantification ranged between 0.3-0.4 ng g−1, 0.045-0.06 ng g−1 and 0.003-0.004 ng g−1 for BPA, TCS and 4n-NP in different tissues, respectively. The method was applied for the determination of BPA, TCS and 4n-NP in paired adipose tissue, liver and brain samples from 11 individuals. BPA could be detected in almost all tissues, with the highest concentrations found in adipose tissue (mean 3.78 ng g−1), followed by liver (1.48 ng g−1) and brain (0.91 ng g−1). TCS showed the highest concentrations in liver (3.14 ng g−1), followed by adipose tissue (0.61 ng g−1), while it could be detected in only one brain sample. Levels of 4n-NP were much lower, mostly undetected, and therefore 4n-NP is considered of minor importance for human exposure. Despite the measurable concentrations in adipose tissue, these compounds seem to have a low bioaccumulation potential. The reported concentrations of free BPA in the various tissues are slight disagreement with pharmacokinetic models in humans and rats and therefore the possibility of external contamination with BPA during sample collection/storage cannot be ruled out.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏