首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Chang MB  Chi KH  Chang SH  Yeh JW 《Chemosphere》2007,66(6):1114-1122
Partitioning of PCDD/F congeners between vapor/solid phases and removal and destruction efficiencies achieved with selective catalytic reduction (SCR) system for PCDD/Fs at an existing municipal waste incinerator (MWI) and metal smelting plant (MSP) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP, operating temperature: 230 degrees C), wet scrubbers (WS, operating temperature: 70 degrees C) and SCR (operating temperature: 220 degrees C) as major air pollution control devices (APCDs). PCDD/F concentration measured at stack gas of the MWI investigated is 0.728 ng-TEQ/Nm(3). The removal efficiency of WS+SCR system for PCDD/Fs reaches 93% in the MWI investigated. The MSP investigated is equipped with EP (operating temperature: 240 degrees C) and SCR (operating temperature: 290 degrees C) as APCDs. The flue gas sampling results also indicate that PCDD/F concentration treated with SCR is 1.35 ng-TEQ/Nm(3). The SCR system adopted in MSP can remove 52.3% PCDD/Fs from flue gases (SCR operating temperature: 290 degrees C, Gas flow rate: 660 kN m(3)/h). In addition, the distributions of PCDD/F congeners observed in the flue gases of the MWI and MSP investigated are significantly different. This study also indicates that the PCDD/F congeners measured in the flue gases of those two facilities are mostly distributed in vapor phase prior to the SCR system and shift to solid phase (vapor-phase PCDD/Fs are effectively decomposed) after being treated with catalyst. Besides, the results also indicate that with SCR highly chlorinated PCDD/F congeners can be transformed to lowly chlorinated PCDD/F congeners probably by dechlorination, while the removal efficiencies of vapor-phase PCDD/Fs increase with increasing chlorination.  相似文献   

2.
Yang CC  Chang SH  Hong BZ  Chi KH  Chang MB 《Chemosphere》2008,73(6):890-895
Development of effective PCDD/F (polychlorinated dibenzo-p-dioxin and dibenzofuran) control technologies is essential for environmental engineers and researchers. In this study, a PCDD/F-containing gas stream generating system was developed to investigate the efficiency and effectiveness of innovative PCDD/F control technologies. The system designed and constructed can stably generate the gas stream with the PCDD/F concentration ranging from 1.0 to 100ng TEQ Nm(-3) while reproducibility test indicates that the PCDD/F recovery efficiencies are between 93% and 112%. This new PCDD/F-containing gas stream generating device is first applied in the investigation of the catalytic PCDD/F control technology. The catalytic decomposition of PCDD/Fs was evaluated with two types of commercial V(2)O(5)-WO(3)/TiO(2)-based catalysts (catalyst A and catalyst B) at controlled temperature, water vapor content, and space velocity. 84% and 91% PCDD/F destruction efficiencies are achieved with catalysts A and B, respectively, at 280 degrees C with the space velocity of 5000h(-1). The results also indicate that the presence of water vapor inhibits PCDD/F decomposition due to its competition with PCDD/F molecules for adsorption on the active vanadia sites for both catalysts. In addition, this study combined integral reaction and Mars-Van Krevelen model to calculate the activation energies of OCDD and OCDF decomposition. The activation energies of OCDD and OCDF decomposition via catalysis are calculated as 24.8kJmol(-1) and 25.2kJmol(-1), respectively.  相似文献   

3.
Hung PC  Lo WC  Chi KH  Chang SH  Chang MB 《Chemosphere》2011,82(1):72-77
A laboratory-scale multi-layer system was developed for the adsorption of PCDD/Fs from gas streams at various operating conditions, including gas flow rate, operating temperature and water vapor content. Excellent PCDD/F removal efficiency (>99.99%) was achieved with the multi-layer design with bead-shaped activated carbons (BACs). The PCDD/F removal efficiency achieved with the first layer adsorption bed decreased as the gas flow rate was increased due to the decrease of the gas retention time. The PCDD/F concentrations measured at the outlet of the third layer adsorption bed were all lower than 0.1 ng I-TEQ Nm−3. The PCDD/Fs desorbed from BAC were mainly lowly chlorinated congeners and the PCDD/F outlet concentrations increased as the operating temperature was increased. In addition, the results of pilot-scale experiment (real flue gases of an iron ore sintering plant) indicated that as the gas flow rate was controlled at 15 slpm, the removal efficiencies of PCDD/F congeners achieved with the multi-layer reactor with BAC were better than that in higher gas flow rate condition (20 slpm). Overall, the lab-scale and pilot-scale experiments indicated that PCDD/F removal achieved by multi-layer reactor with BAC strongly depended on the flow rate of the gas stream to be treated.  相似文献   

4.
Unintentionally produced persistent organic pollutants (UPOPs) include polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), dioxin-like polychlorinated biphenyls (dl-PCBs), pentachlorobenzene (PeCBz), and hexachlorobenzene (HxCBz). With the booming of municipal waste incinerators (MWIs) in China, the emission of UPOPs has generated great concern. As an alternative technology of dioxin control, catalytic decomposition has not been used in China, mainly due to the absence of national demonstration projects. Also, the simultaneous removal of various UPOPs has not been well investigated.In this study, a pilot-scale selective catalytic oxidative (SCO) system using a self-developed honeycomb catalyst was built and tested in a typical municipal waste incinerator (MWI) of China. The original concentration of PCDD/Fs in flue gas after the treatment of activated carbon injection (ACI) still exceeded the national emission standard (0.1 ng I-TEQ/Nm3), while the concentrations of PeCBz and HxCBz were one order of magnitude higher than that of PCDD/Fs. For the testing temperature varying from 300 to 200 °C, the removal efficiency of PCDD/Fs range from 39 to 95 %, followed by dl-PCBs with the range of 56–89 %. PeCBz and HxCBz were also removed, though their removal efficiencies were lower than those of PCDD/Fs and dl-PCBs. Both temperature and degree of chlorination influence the removal efficiencies.  相似文献   

5.
Dechlorination of commercial mixtures of polychlorinated biphenyls (PCB) as well as polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) on extracted and non-extracted fly ash obtained from municipal waste incinerator (MWI) was studied in closed systems under nitrogen atmosphere at temperatures of 260°C and 340°C. Decomposition results (given as the difference between PCB or PCDD/F molar amounts before and after the experiment (in %) due predominantly to dechlorination reactions) and detoxification data (expressed similarly but related to toxic PCB and PCDD/F congeners only and given in I-TEQ units) are reported. Detoxification of Delor 105/80T at 260°C and 340°C at a loading of 0.65 wt% was 99.48% and 100%, respectively. The decomposition of Delor 103 at 340°C and for the loading of 0.75 wt% corresponded to 99.99%. The detoxification capability of PCDD/Fs on extracted and non-extracted fly ash for loading of 130 and 264 ng/0.4 g of fly ash at 340°C made 96 and 98%, respectively.  相似文献   

6.
Hsu JF  Guo YL  Yang SY  Liao PC 《Chemosphere》2005,61(9):1231-1243
In 1978-1979, a mass poisoning occurred in central Taiwan from rice-bran oil contaminated by heat-degraded PCBs was later called the Yucheng (oil disease in Chinese). Only a few studies have so far investigated the levels of specific polychlorinated biphenyl (PCB) or polychlorinated dibenzodioxin/furan (PCDD/F) congeners in the Yucheng victims. This study aimed to investigate the serum residual levels of thirty-three PCBs and seventeen 2,3,7,8-substituted PCDD/F congeners in the Yucheng victims 15 years after the exposure. Forty-one blood samples were collected from individual Yucheng victims in 1994-1995. The mean levels of total 33 PCBs and 17 PCDD/Fs were 2468 ng/g lipid (13.3 ng/g sample) and 6550 pg/g lipid (30.9 pg/g sample) respectively. The higher levels were found in PCBs #99, #138, #153, #156, #170, #179, and #180 among 33 PCB congeners, while 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, and OCDD had the higher concentrations among 17 PCDD/F congeners. The total TEQ was contributed in decreasing order by 10 PCDFs (44%), three non-ortho-PCBs (24%), six mono-ortho-PCBs (20%), and seven PCDDs (12%). The mean total PCB levels and TEQ value of the 17 PCDD/Fs in the Yucheng victims 15 years after the toxic exposure were still 9 and 46 times higher than those in the general population in Taiwan. Principle component analysis (PCA) indicated that seven PCB congeners, PCBs #99, #138, #153, #156, #170, #179, and #180, accounted for 73% of the total variances in PCBs. On the other hand, six PCDD/F congeners, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 1,2,3,6,7,8-HxCDD, 1,2,3,4,6,7,8-HpCDF, and OCDD, accounted for 97% of the total variances in PCDD/Fs. In addition, PCA revealed that at least three characteristic patterns of congener profiles for PCBs were observed among the Yucheng victims. Similar trend was also observed for PCDD/Fs. These patterns may reflect distinctive exposure scenarios and/or different metabolizing capabilities among the Yucheng victims. We suggest that these patterns, in contrast to total PCB and PCDD/F levels, may be valuable for the future epidemiologic studies when linking exposure with specific health effect.  相似文献   

7.
Particle-bound polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) were monitored at two sites in northern Greece for an eight-month period in 1999. PCDD/F concentrations were close to the lower end of reported values worldwide. Excepting a few cases, the PCDD/Fs homologue profile was stable. The gaseous PCDD/F fractions calculated were found to account for a small percentage of the total concentrations (<2% for OCDD/Fs and HpCDD/Fs, while 30-35% for TCDFs). Particle-bound PCBs were also found at low concentrations which, however, were higher at the urban site. Calculations of the dry deposition of particulate PCDD/ Fs and PCBs gave mean values of 0.52 and 0.59 pg I-TEQ/m2/day of PCDD/Fs, while 242 and 74 pg/m2/day of sigmaPCBs for the urban and the semirural areas respectively. An anticorrelation of PCDD/F concentrations with ambient temperature was derived particularly for the lower chlorinated congeners. A weak association with winds of western and southern origin was also observed. Factor analysis and literature source profiles were employed to identify possible emission sources. It was appeared that the PCDD/F compositional pattern of TSP is influenced by mixed sources the most prominent being uncontrolled fires and car exhausts.  相似文献   

8.
Chang MB  Chi KH  Chang-Chien GP 《Chemosphere》2004,55(11):1457-1467
Partitioning of PCDD/F congeners between gaseous and particulate phases and removal efficiencies of the air pollution control devices (APCDs) for PCDD/Fs at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS) and selective catalytic reduction system (SCR) as APCDs. The average PCDD/F concentration of stack gas is 1.49 ng/N m3, and the International Toxic Equivalent Quantity (I-TEQ) is 0.043 ng-I-TEQ/N m3. The EP increases PCDD/F concentration by 174.0% while the average removal efficiency of WS + SCR system for PCDD/Fs reaches 99.1%. In addition, the PCDF removal efficiency achieved with WS + SCR system (97.1–99.8%) is higher than that for PCDDs (96.5–99.3%). The results obtained on gas/particulate partitioning in flue gas indicate that the particulate-phase PCDD/Fs accounted for 65% at the inlet of EP, 20% at the outlet of EP and 50% at the stack, respectively, of the total PCDD/F concentrations. This study also indicates that as the chlorination level of PCDD/F congeners increases, the percentage of PCDD/Fs existing in gas phase decreases in all flue gas samples.  相似文献   

9.
Wang HC  Hwang JF  Chi KH  Chang MB 《Chemosphere》2007,67(9):S177-S184
The PCDD/F concentrations and removal efficiencies achieved with air pollution control devices (APCDs) during different operating periods (start-up, normal operation, and shut-down) at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS), and selective catalytic reduction system (SCR) as APCDs. The sampling results indicate that the PCDD/F concentrations at the EP inlet during start-up period were 15 times higher than that measured during normal operation period. The PCDD/F concentration observed at shut-down period was close to that measured at normal operation period. The CO concentration was between 400 and 1000 ppm during start-up period, which was about 50 times higher compared with the normal operation. Hence, combustion condition significantly affected the PCDD/F formation concentration during the waste incineration process. In addition, the distributions of the PCDD/F congeners were similar at different operating periods. During the normal operation and shut-down periods, the EP decreases the PCDD/F concentration (based on TEQ) by 18.4-48.6%, while the removal efficiency of PCDD/Fs achieved with SCR system reaches 99.3-99.6%. Nevertheless, the PCDD/F removal efficiency achieved with SCR was only 42% during the 19-h start-up period due to the low SCR operating temperature (195 degrees C).  相似文献   

10.
Formation and mitigation of PCDD/Fs in iron ore sintering   总被引:1,自引:0,他引:1  
Ooi TC  Lu L 《Chemosphere》2011,85(3):291-299
The sintering of iron ore is presently a significant industrial source of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) worldwide owing to the fundamental requirement of the operation of a high temperature process to pre-treat fines and to recycle plant by-products arising from the integrated iron and steelworks. The process is a noteworthy contributor of PCDD/F indirectly due to decreasing PCDD/F releases from municipal solid waste incineration. Commonly PCDD/F formation from the process is associated with the addition of oily mill scales although raw material containing a combination of C, Cl and specific metal catalyst has been shown to drastically increase PCDD/F formation in the process. The degenerate graphitic structure of carbon present in coke fuel and soot formed and the chemistry of catalytic metals and Cl are important factors. A review on PCDD/F emission in this process has been carried out, including examination of its formation mechanism, congener distribution, contributing factors and mitigation strategies, with emphasis on the use of inhibiting compound to achieve suppression. A detailed analysis of the de novo and precursor theories of formation and the contributing factor is given since the subject of PCDD/F formation is still controversial. The de novo formation pathway identified in sinter plants and controlled studies performed in the laboratory as well as at pilot-scale are discussed; where appropriate, a comparison is drawn between sintering and other thermal processes emitting PCDD/Fs. Summary of the latest developments in PCDD/F downstream abatement strategies presently employed in full scale industrial plants is provided. Potential inhibiting compounds are discussed in terms of their mode of action and merits under sintering conditions.  相似文献   

11.
The atmospheric fate of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) was simulated for the year 2000 in North America using a SMOKE/CMAQ-based chemical transport model that was modified for this purpose. The 1999 USEPA emission inventories of PCDD/Fs and criteria pollutants were used. The 1995 Canadian emission inventory of criteria pollutants and the 1995 Canadian area source emissions for PCDD/Fs were used with the 2000 Canadian point source emissions. Modifications to CMAQ involved coupling it with dual organic matter (OM) absorption and black carbon (BC) adsorption models to calculate PCDD/F gas–particle partitioning. The model satisfactorily reproduced the particle bound fractions at all rural sites for which there were measured data and across the whole domain, the modeled vs. measured differences in particle bound fractions were less than 20% for nearly all congeners. The model predicted ambient air PCDD/F concentrations were also consistent with measurements. Simulated deposition fluxes were within 58% of direct measurements. PCDD/F atmospheric depositions to each of the Great Lakes were estimated for the year 2000. The results indicate that approximately 76% of the total deposition of PCDD/Fs to the Great Lakes (in W-TEQ, or toxic equivalent units as defined by the World Health Organization) is attributed to PCDD/Fs absorbed into OM in aerosol. For all of the lakes, more than 92% of all deposition is particle phase wet deposition and only 5–8% is particle phase dry deposition. Wet deposition from the gas phase is negligible. Of the 17 toxic PCDD/F congeners, the Cl4–5DD/F compounds contribute approximately 70% to the total atmospheric deposition to the Great Lakes. The seasonal changes in the PCDD/F deposition flux track variations in ambient temperature.  相似文献   

12.
Hart JR 《Chemosphere》2008,72(1):75-78
Emissions and inlet concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) have been measured from a catalytic oxidizer and a thermal oxidizer. The catalyst inlet temperature was 427 degrees C. The thermal oxidizer operating temperature was 791 degrees C. Data of the toxic dioxin and furan congeners are reported. Important results of this field study are: (1) the catalytic oxidizer in this study produced an increase in PCDD/PCDF congener concentration of almost 10-fold from the inlet to the outlet (stack), thus verifying results of a previous study that evaluated only PCDD/PCDF emissions. All congeners increased from inlet to the stack. (2) The thermal oxidizer had little effect on PCDD/PCDF levels. There was a decrease in four of the congeners and an increase in 13 congeners. (3) Ambient air was the main source of PCDD/PCDFs in the stack emissions of the thermal oxidizer in this study. Laboratory investigations are needed to understand how PCDD/PCDFs are formed (and emitted) under conditions of this study.  相似文献   

13.
This study shows the catalyzing effects of iron and copper on the formation of chlorinated compounds such as chlorobenzenes (ClBzs), chlorophenols (CIPhs), polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Both total concentrations and congener distributions have been studied. The parameters and conditions varied during the combustion tests were the complete and incomplete combustion and the metal and chlorine addition. The incomplete combustion promoted the formation of organic chlorinated compounds in flue gas particles. Highly chlorinated congeners of PCDD/F were dominant in the flue gas particles, whereas the importance of lower chlorinated congener were increased in the gas phase. In the complete combustion conditions the concentrations of PCDD/Fs increased when the degree of chlorination were high, nevertheless the concentrations of tetra and penta PCDD/Fs were higher in the gas phase than the concentrations in the fly ash particles. Organic chlorine promoted the formation of chlorinated compounds more effectively than inorganic chlorine, which instead promoted the formation of PCDD/Fs in the gas phase, especially with copper catalyst. Different concentration levels of chlorinated compounds were observed in the gas phase and in particles when the chlorine source and combustion conditions were varied from incomplete to optimum conditions. Both copper and iron seem to have a catalytic effect on PCDD/F formation.  相似文献   

14.
Emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alkene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alkenes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

15.
Spruce (Picea abies (L.) Karst.) needles were exposed to exhaust gas containing polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) generated by combustion of polyvinyl chloride, wood, high-density polyethylene, and styrene. Photodegradation of PCDD/Fs adsorbed on spruce needles under sunlight irradiation was studied. The photodegradation of PCDD/Fs follows pseudo-first-order reaction kinetics, with photolysis half-lives ranging between 40 and 100 h. The photolysis rates of PCDF congeners are higher than PCDD congeners with the same chlorinated substitutions. Higher chlorinated PCDD/Fs tend to photolyze slowly. The wax components in spruce needles may act as proton donors and accelerate the photolysis rate. C-Cl cleavage through the addition of protons to PCDD/F molecules may be an important route for PCDD/Fs photodegradation.  相似文献   

16.
The concentrations of 17 polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs), and 12 dioxin-like polychlorinated biphenyls (dl-PCBs) were measured in sediment and key species as an initial investigation on PCDD/Fs and dl-PCBs contamination in the Mondego estuary (Portugal). The results demonstrated that the values of the total PCDD/Fs (∑PCDD/Fs) concentrations were considerably lower than those of the sum of dl-PCBs (∑dl-PCBs) in all the studied samples. Regarding the contribution of individual congeners, OCDD was the predominant PCDD/F and the mono-ortho PCB 118 and PCB 105 were the dominant PCBs in the majority of the samples. Our results suggest that PCDD/Fs and PCBs behave quite differently along the aquatic food web: ∑PCDD/Fs concentrations were lower in higher trophic-level organisms with fish presenting a distinct PCDD/Fs congeners profile; on the contrary, the higher ∑dl-PCBs values were found in upper-level biota, although not exclusively, and quite similar dl-PCBs congener profiles were observed in nearly all the studied species.  相似文献   

17.
Despite their environmental importance, there are still relatively few historical studies of the environmental occurrence of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), especially in middle Europe. Trends in PCBs and PCDD/Fs were, therefore, assessed in lake sediments of the Grosser Arbersee over the past 130 years (1860-1990). Ballschmiter-PCB concentrations (congeners # 28, 52, 101, 138, 153, 180) increased between 1946 and 1972 from 4.2 to 32.0 microg kg(-1) dry wt, but have since decreased to 25.6 microg kg(-1) dry wt. High chlorinated PCB congeners reached their maxima earlier (1968-1972) than low chlorinated congeners (1985-1991). These trends were consistent with patterns expected from the production and use of PCBs and their precursors. PCDD/F concentrations increased between 1950 from 0.6 microg kg(-1) dry wt to 2.3 microg kg(-1) dry wt in 1977, falling to 1.7 microg kg(-1) dry wt by 1993. PCDF concentrations exceeded those of PCDD until 1968, but afterwards PCDDs (especially OCDD) were predominant. These patterns suggest that domestic heating and waste combustion were the most likely sources, but pollution from local industries, such as metal smelting and glass production, might also have been involved. The data provide a valuable case study from central Europe which confirms the overall declining trends of PCB and PCDD/F contamination shown elsewhere.  相似文献   

18.
Song GJ  Kim SH  Seo YC  Kim SC 《Chemosphere》2008,71(2):248-257
Dechlorination and destruction characteristics of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/PCDFs) in fly ashes from commercial-scale municipal solid waste incinerators by low temperature thermal treatment using a laboratory-scale heating system were investigated. Experiments were carried out in reducing atmosphere at temperatures of 300 degrees C, 450 degrees C and 600 degrees C respectively, for the treatment time of 1h and 3h. Concentrations of PCDDs/PCDFs in raw fly ashes ranged from 35.5 to 107.3 microg kg(-1) (1.5-3.4 microg TEQ kg(-1)) and treated fly ashes ranged from 0.34 to 45.3 microg kg(-1) (0.012-1.63 microg TEQ kg(-1)). Concentrations of PCDDs/PCDFs in fly ashes treated at the different temperatures and times were observed to decrease with increase of treatment temperature and time by dechlorination or destruction. The distribution of octa- and hepta-chlorinated congeners were decreased and tetra-, penta- and hexa-chlorinated congeners were increased at 300 degrees C and 450 degrees C, but the distribution of octa- and hepta-chlorinated congeners were increased and tetra-, penta- and hexa-chlorinated congeners were again decreased at 600 degrees C. Total destruction efficiencies of PCDDs/PCDFs in fly ashes showed above 95% at the treatment temperature of 450 degrees C for 3h. However, removal efficiency of each congener in fly ashes varied, especially, 2,3,7,8-TeCDD and 1,2,3,7,8-PeCDD in fly ash A increased. And the dechlorination and destruction characteristics of PCDDs/PCDFs in fly ash A and B was different due to difference in contents of Ca-compounds and metal oxides such as CuO and PbO in fly ashes.  相似文献   

19.
Yang JS  Seo J  Shin JH  Ahn YG  Lee DW  Hong J 《Chemosphere》2004,54(10):1451-1457
Eight samples of processed food salt collected from five plants in Korea were analyzed for 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) using liquid-liquid extraction, clean-up procedures, and high resolution gas chromatography-high resolution mass spectrometry. The study included the analyses of two kinds of salt product sample: bamboo-salt and parched salt. The levels of toxic PCDD/Fs found in the salt product samples were extremely low: the results revealed TEQ levels ranging between the sub pg TEQ/g and sub fg TEQ/g. The differences in the TEQ values of toxic PCDD/F were observed between the salt product samples, which were treated with different frequency of baking using four different fuels (firewood, pine wood, pine resin, and indirect heating by gas) at temperatures from 300 to 2000 degrees C. In bamboo-salt samples, the concentrations and TEQ values of toxic PCDD/Fs ranged between 0.57-66 pg/g and 5.7x10(-5)-0.64 pg TEQ/g, respectively. PCDD/Fs levels in bamboo-salts baked by firewood were found to be higher than those baked by pinewood or pine resin. In parched salt samples, the concentrations and TEQ values of toxic PCDD/Fs ranged between 0.97-3.7 pg/g and 0.0097-0.017 pg TEQ/g, respectively. The data was discussed regarding the concentration and the distribution pattern of congeners.  相似文献   

20.
Haglund P 《Ambio》2007,36(6):467-474
This review provides a summary of methods for treating soils contaminated with polychlorinated aromatic compounds, especially polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Unlike many other soil pollutants, PCDD/Fs bind tightly to the soil, which severely reduces the efficiency of most aqueous treatment procedures and leaves few realistic alternatives besides the traditional containment techniques (landfill, solidification/stabilization, and in situ vitrification). Incineration has long been, and still is, the most efficient destruction technique, with a removal efficiency of >99.9999%. However, supercritical water oxidation, base-catalyzed decomposition, steam distillation, and various extraction techniques, such as solvent and liquefied gas and subcritical water extraction, may provide removal efficiencies of >95%. Many of the alternative techniques are expected to be cheaper than incineration and may therefore be attractive for moderately polluted soils. However, some of them are at an early stage of development and need to be further tested before their true potential can be assessed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号