首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Iron electrodes were used for electrocoagulation (EC) treatment of wastewater from a dairy plant. Electrolysis time, pH, current density and distance between electrodes were considered to assess the removal efficiency of chemical oxygen demand (COD), total solids (TS) and their fractions and turbidity. Samples were collected from the effluent of a dairy plant using a sampling methodology proportional to the flow. The treatments were applied according to design factorial of half fraction with two levels of treatments and three repetitions at the central point. The optimization of parameters for treating dairy industry effluent by electrocoagulation using iron electrodes showed that electric current application for 15 minutes, an initial sample pH close to neutral (pH 7.0) and a current density of 50 A (.)(m-2) resulted in a significant reduction in COD by 58 %; removal of turbidity, suspended solids and volatile suspended solids by 95 %; and a final treated effluent pH of approximately 9.5. Negative consequences of the type of electrode used were the emergence of an undesirable color and an increase in the proportion of dissolved solids in the treated effluent.  相似文献   

2.
Lai CL  Lin SH 《Chemosphere》2004,54(3):235-242
Treatment of copper chemical mechanical polishing (CMP) wastewater from a semiconductor plant by electrocoagulation is investigated. The CMP wastewater was characterized by high suspended solids (SS) content, high turbidity (NTU), chemical oxygen demand (COD) concentration up to 500 mgl(-1) and copper concentration up to 100 mgl(-1). In the present study, electrocoagulation was employed to treat the CMP wastewater with an attempt to simultaneously lower its turbidity, copper and COD concentrations. The test results indicated that electrocoagulation with Al/Fe electrode pair was very efficient and able to achieve 99% copper ion and 96.5% turbidity removal in less than 30 min. The COD removal obtained in the treatment was better than 85%, with an effluent COD below 100 mgl(-1). The effluent wastewater was very clear and its quality exceeded the direct discharge standard. In addition, sludge settling velocities after electrocoagulation were measured and the data were employed to verify the empirical sludge settling velocity models. Finally, the sludge settling characteristic data were also utilized to establish the relation between the solids flux (G) and the initial solids concentration.  相似文献   

3.
Textile plant wastewater being treated in a facultative pond system had too high of a solids concentration to be reused in the dying and rinsing processes. Electrocoagulation was evaluated to further treat the pond effluent to remove turbidity, which was caused by dyes and microorganisms. A range of amperages were tested for removal of turbidity and chemical oxygen demand (COD). Electrocoagulation lowered the turbidity from 1400 NTU to below 50 NTU; and COD was lowered from 550 mg/L to approximately 250 mg/L, which was acceptable for reuse. In addition, a laboratory-scale sedimentation study was conducted on the electrocoagulated pond effluent, which indicated that a settling time of 35 minutes would provide for 80% removal of suspended solids, which was acceptable for reuse of the water in plant processes.  相似文献   

4.
选择DSA电极中的钛基掺硼金钢石膜电极(Ti/BDD),用于制革综合废水的电催化氧化处理研究,考察了在不同的电流密度、电压、电解质、pH值和电解时间等因素对COD去除率和电流效率的影响。结果表明,控制电流密度为30mA/cm2,电压为8.0 V,电解质(NaCl)浓度为2.0 g/L,pH为4.0,电催化氧化处理2 h后,废水的COD和NH4+-N的去除率分别达到了83.6%和90.3%,BOD/COD为0.45,比能耗为35.34 kWh/kg COD,电流效率为37%。  相似文献   

5.
A combined treatment of electrocoagulation and ultrasound was proposed to solve some problems which exist in the phosphorus removal processes in fine chemical industry. The intermittently discharged wastewater has the features of high initial phosphorus concentration and wide initial pH variation. The electrocoagulation–ultrasound effective performance for the removal of phosphorus was investigated. The results obtained from synthetic wastewater showed that the total phosphorus (TP) decreased from 86 to about 0.4 mg/L, and the removal efficiency reached about 99.6 %, when ultrasound was applied to the electrocoagulation cell under the optimum working conditions in 10 min. Comparatively, the TP removal efficiency of electrocoagulation group was 81.3 % and the ultrasound group has almost no change. Therefore, we can conclude that the electrocoagulation and ultrasound synergistic effect can effectively degrade high-phosphorus wastewater. We have discussed the impact of various parameters on the electrocoagulation–ultrasound based on the phosphorus removal efficiency. The results obtained from synthetic wastewater showed that the optimum working pH was found to be 6, allowing the effluent to be met the emission standards without pH adjustment. An increased current enhanced the speed of treatment significance, but higher current (>40 mA/cm2) enhanced ultrasonic cavitation effect causing flocculation ineffective. In addition, it was found that the optimum ultrasonic power was 4 W/cm2 and the frequency was 20 kHz. The best ultrasound intervention and ultrasonic irradiation time were processed with electrocoagulation simultaneously. The results indicated that the electrocoagulation–ultrasound could be utilized as an attractive technique for removal of phosphate in the real wastewater.  相似文献   

6.
The physical and chemical qualities of the process effluent and the tailings dam wastewater of AngloGold-Ashanti Limited, a gold mining company in Ghana, were studied from June to September, 2010. The process effluent from the gold extraction plant contains high amounts of suspended solids and is therefore highly turbid. Arsenic, copper and cyanide were identified as the major pollutants in the process effluent with average concentrations of 10.0, 3.1 and 21.6 mg?L?1, respectively. Arsenic, copper, iron and free cyanide (CN?) concentrations in the process effluent exceeded the Ghana EPA discharge limits; therefore, it is necessary to treat the process effluent before it can be discharged into the environment. Principal component analysis of the data indicated that the process effluent characteristics were influenced by the gold extraction process as well as the nature of the gold-bearing ore processed. No significant correlation was observed between the wastewater characteristics themselves, except for the dissolved oxygen and the biochemical oxygen demand. The process effluent is fed to the Sansu tailings dam, which removes 99.9 % of the total suspended solids and 99.7 % of the turbidity; but copper, arsenic and cyanide concentrations were still high. The effluent produced can be classified as inorganic with a high load of non-biodegradable compounds. It was noted that, though the Sansu tailings dam stores the polluted effluent from the gold extraction plant, there will still be serious environmental problems in the event of failure of the dam.  相似文献   

7.
In the present study, feasibility of recovering the coagulant from water treatment plant sludge with sulphuric acid and reusing it in post-treatment of upflow anaerobic sludge blanket (UASB) reactor effluent treating municipal wastewater were studied. The optimum conditions for coagulant recovery from water treatment plant sludge were investigated using response surface methodology (RSM). Sludge obtained from plants that use polyaluminium chloride (PACl) and alum coagulant was utilised for the study. Effect of three variables, pH, solid content and mixing time was studied using a Box–Behnken statistical experimental design. RSM model was developed based on the experimental aluminium recovery, and the response plots were developed. Results of the study showed significant effects of all the three variables and their interactions in the recovery process. The optimum aluminium recovery of 73.26 and 62.73 % from PACl sludge and alum sludge, respectively, was obtained at pH of 2.0, solid content of 0.5 % and mixing time of 30 min. The recovered coagulant solution had elevated concentrations of certain metals and chemical oxygen demand (COD) which raised concern about its reuse potential in water treatment. Hence, the coagulant recovered from PACl sludge was reused as coagulant for post-treatment of UASB reactor effluent treating municipal wastewater. The recovered coagulant gave 71 % COD, 80 % turbidity, 89 % phosphate, 77 % suspended solids and 99.5 % total coliform removal at 25 mg Al/L. Fresh PACl also gave similar performance but at higher dose of 40 mg Al/L. The results suggest that coagulant can be recovered from water treatment plant sludge and can be used to treat UASB reactor effluent treating municipal wastewater which can reduce the consumption of fresh coagulant in wastewater treatment.  相似文献   

8.
The main objective of this study was to investigate the feasibility of coagulation as a post-treatment method of anaerobically treated primary municipal wastewater. Both mesophilic and ambient (20 degrees C) temperature conditions were investigated in a laboratory-scale upflow anaerobic sludge bed (UASB) reactor. In addition, optimization of the coagulant, both in terms of type and dose, was performed. Finally, phosphorus removal by means of aluminum and iron coagulation and phosphorus and ammonia nitrogen removal by means of struvite precipitation were studied. Anaerobic treatment of primary effluent at low hydraulic retention times (less than 15 hours) resulted in mean chemical oxygen demand (COD) removals ranging from 50 to 70%, while, based on the filtered treated effluent, the mean removals increased to 65 to 80%. Alum coagulation of the UASB effluent gave suspended solids removals ranging from approximately 35 to 65%. Turbidity removal reached up to 80%. Remaining COD values after coagulation and settling were below 100 mg/L, while remaining total organic carbon (TOC) levels were below 50 mg/L. Filterable COD levels were generally below 60 mg/L, while filterable TOC levels were below 40 mg/L. All coagulants tested, including prepolymerized aluminum and iron coagulants, demonstrated similar efficiency compared with alum for the removal of suspended solids, COD, and TOC. Regarding struvite precipitation, optimal conditions for phosphorus and nitrogen removal were pH 10 and molar ratio of magnesium: ammonia-nitrogen: phosphate-phosphorus close to the stoichiometric ratio (1:1:1). During struvite precipitation, removal of suspended solids reached 40%, while turbidity removal reached values up to 80%. The removal of COD was approximately 30 to 35%; yet, when removal of organic matter was based on the treated filterable COD, the removal increased to approximately 65%. In addition, nitrogen was removed by approximately 70%, while phosphorus removal ranged between approximately 30 and 45% on the basis of the initial phosphorus concentration. Finally, size fractionation of the organic matter (COD) showed that the various treatment methods were capable of removing different fractions of the organic matter.  相似文献   

9.
The aim of this study is the treatment of Basic Red 29 (BR29) dye solution using hybrid iron-aluminum electrodes by electrocoagulation and electro-Fenton methods. The effect of current density, initial pH, supporting electrolyte, H2O2, and initial dye concentration on dye removal efficiency was investigated, and the best experimental conditions were obtained. Time-coarse variation of UV-Vis spectra and toxicity and chemical oxygen demand (COD) removal were also examined at the best experimental conditions. Both systems were found very successful for the removal of BR29 dye. The removal efficiency of >95 % for BR29 dye solution was reached easily in a short time. At the best experimental conditions, for the initial BR29 concentration of 100 mg/L, >95 % BR29 dye and 71.43 % COD removal were obtained after 20 and 40 min of electrolysis, respectively. Additionally, toxicity results for electro-Fenton treatment of 100 mg/L BR29 were also very promising. According to the results obtained, although electro-Fenton is more effective, both systems can be used successfully to treat textile wastewater including dyes.  相似文献   

10.
Three different combinations of treatment techniques, i.e. electrocoagulation combined with microfiltration (EMR), membrane bioreactor (MBR) and electrocoagulation integrated with membrane bioreactor (hybrid MBR, (HMBR)), were analysed and compared for the treatment of tannery wastewater operated for 7 days under the constant trans-membrane pressure of 5 kPa. HMBR was found to be most suitable in performance as well as fouling reduction, with 94 % of chemical oxygen demand (COD) removal, 100 % chromium removal and 8 % improvement in percentage reduction in permeate flux compared to MBR with only 90 % COD removal and 67 % chromium removal. The effect of mixed liquor suspended solids on fouling was also investigated and was found to be insignificant. EMR was capable of elevating the flux but was not as efficient as HMBR and MBR in COD removal. Fouling reduction by HMBR was further confirmed by SEM-EDX and particle size analysis.  相似文献   

11.
电絮凝处理煤层气产出水   总被引:4,自引:2,他引:2  
采用电絮凝法处理煤层气产出水,通过铁和铝2种电极材料的处理效果的比较,选择铝电极进行实验,研究了电极间距、原水pH值以及电流密度等因素对电絮凝处理效果的影响。实验结果表明,电絮凝法对煤层气产出水的化学需氧量(COD)和固体悬浮物(SS)具有良好的去除效果,原水pH接近中性时处理效果较好,电絮凝处理过程中不需添加可溶性盐和改变pH值。实验中确定的电絮凝处理条件为:电极间距1 cm,电流密度30 A/m2,反应10 min后,出水的COD、SS分别为9.6 mg/L和8.5 mg/L,去除率分别达到75.1%和88.8%,出水pH为7.8,电能消耗为1.75 kWh/m3。  相似文献   

12.
The present study provides an optimization of electrocoagulation process for the recovery of hydrogen and removal of nitrate from water. In doing so, the thermodynamic, adsorption isotherm, and kinetic studies were also carried out. Aluminum alloy of size 2 dm2 was used as anode and as cathode. To optimize the maximum removal efficiency, different parameters like effect of initial concentration, effect of temperature, pH, and effect of current density were studied. The results show that a significant amount of hydrogen can be generated by this process during the removal of nitrate from water. The energy yield calculated from the hydrogen generated is 3.3778 kWh/m3. The results also showed that the maximum removal efficiency of 95.9 % was achieved at a current density of 0.25 A/dm2, at a pH of 7.0. The adsorption process followed second-order kinetics model. The adsorption of NO 3 ? preferably fitting the Langmuir adsorption isotherm suggests monolayer coverage of adsorbed molecules. Thermodynamic studies showed that adsorption was exothermic and spontaneous in nature. The energy yield of generated hydrogen was ~54 % of the electrical energy demand of the electrocoagulation process. With the reduction of the net energy demand, electrocoagulation may become a useful technology to treat water associated with power production. The aluminum hydroxide generated in the cell removes the nitrate present in the water and reduced it to a permissible level making the water drinkable.  相似文献   

13.
Dairy wastewater is characterized by a high content of hardly biodegradable dissolved, colloidal, and suspended organic matter. This work firstly investigates the performance of two individual electrochemical treatments, namely electrocoagulation (EC) and electro-oxidation (EO), in order to finally assess the mineralization ability of a sequential EC/EO process. EC with an Al anode was employed as a primary pretreatment for the conditioning of 800 mL of wastewater. A complete reduction of turbidity, as well as 90 and 81 % of chemical oxygen demand (COD) and total organic carbon (TOC) removal, respectively, were achieved after 120 min of EC at 9.09 mA cm?2. For EO, two kinds of dimensionally stable anodes (DSA) electrodes (Ti/IrO2-Ta2O5 and Ti/IrO2-SnO2–Sb2O5) were prepared by the Pechini method, obtaining homogeneous coatings with uniform composition and high roughness. The ·OH formed at the DSA surface from H2O oxidation were not detected by electron spin resonance. However, their indirect determination by means of H2O2 measurements revealed that Ti/IrO2-SnO2–Sb2O5 is able to produce partially physisorbed radicals. Since the characterization of the wastewater revealed the presence of indole derivatives, preliminary bulk electrolyses were done in ultrapure water containing 1 mM indole in sulfate and/or chloride media. The performance of EO with the Ti/IrO2-Ta2O5 anode was evaluated from the TOC removal and the UV/Vis absorbance decay. The mineralization was very poor in 0.05 M Na2SO4, whereas it increased considerably at a greater Cl? content, meaning that the oxidation mediated by electrogenerated species such as Cl2, HClO, and/or ClO? competes and even predominates over the ·OH-mediated oxidation. The EO treatment of EC-pretreated dairy wastewater allowed obtaining a global 98 % TOC removal, decreasing from 1,062 to <30 mg L?1.  相似文献   

14.
为了减轻对后续处理中超滤膜的污染,采用电絮凝法处理油田生化出水,降低油田生化出水中的有机物含量。研究了电流强度、曝气时间和pH值对水中总有机碳(TOC)和浊度除去效果的影响以及pH值随曝气时间的变化趋势,通过红外光谱对絮凝处理前后水中总溶解固体进行了分析,优化了电絮凝的工艺条件。研究表明,当水流速度控制在50mL/s,电流强度为2 A,500 mL絮凝出水的曝气时间为30 min时,整套絮凝工艺对TOC的去除率为48%,浊度去除率为42.9%,COD去除率为44%。  相似文献   

15.
Sustainable, environmental friendly, and safe disposal of sewage treatment plant (STP) sludge is a global expectation. Bioremediation performance was examined at different hydraulic retention times (HRT) in 3–10 days and organic loading rates (OLR) at 0.66–7.81 g chemical oxygen demand (COD) per liter per day, with mixed filamentous fungal (Aspergillus niger and Penicillium corylophilum) inoculation by liquid-state bioconversion (LSB) technique as a continuous process in large-scale bioreactor. Encouraging results were monitored in treated sludge by LSB continuous process. The highest removal of total suspended solid (TSS), turbidity, and COD were achieved at 98, 99, and 93 %, respectively, at 10 days HRT compared to control. The minimum volatile suspended solid/suspended solid implies the quality of water, which was recorded 0.59 at 10 days and 0.72 at 3 days of HRT. In treated supernatant with 88 % protein removal at 10 days of HRT indicates a higher magnitude of purification of treated sludge. The specific resistance to filtration (SRF) quantifies the performance of dewaterability; it was recorded minimum 0.049 × 1012 m kg?1 at 10 days of HRT, which was equivalent to 97 % decrease of SRF. The lower OLR and higher HRT directly influenced the bioremediation and dewaterability of STP sludge in LSB process. The obtained findings imply encouraging message in continuing treatment of STP sludge, i.e., bioremediation of wastewater for environmental friendly disposal in near future.  相似文献   

16.
超声强化电絮凝处理洗车废水的试验研究   总被引:1,自引:0,他引:1  
针对洗车行业对水资源的浪费及污染现状,采用超声强化电絮凝处理洗车废水.考察了电流密度、初始pH、极板间距、处理时间等因素对洗车废水处理效果的影响,并讨论了超声强化电絮凝机制.结果表明,超声强化电絮凝处理洗车废水的最佳条件是电流密度1,500 mA/cm2、初始pH无需调节、极板间距为1.5cm、处理20 min,COD与浊度去除率分别为68.77%、96.89%,出水达到《城市污水再生利用城市杂用水水质》(GB/T 18920-2002)要求.可见,超声能改变电絮凝反应动力学过程,强化电絮凝去除污染物效果.  相似文献   

17.
In the present paper, the performance of electrocoagulation (EC) for the treatability of mixed metals (chromium (Cr), copper (Cu), lead (Pb), nickel (Ni), and zinc (Zn)) from metal plating industrial wastewater (EPW) has been investigated. The study mainly focused on the affecting parameters of EC process, such as electrode material, initial pH, distance between electrodes, electrode size, and applied voltage. The pH 8 is observed to be the best for metal removal. Fe–Fe electrode pair with 1-cm inter-electrode distance and electrode surface area of 40 cm2 at an applied voltage of 8 V is observed to more efficient in the metal removal. Experiments have shown that the maximum removal percentage of the metals like Cr, Ni, Zn, Cu, and Pb are reported to be 96.2, 96.4, 99.9, 98, and 99.5 %, respectively, at a reaction time of 30 min. Under optimum conditions, the energy consumption is observed to be 51.40 kWh/m3. The method is observed to be very effective in the removal of metals from electroplating effluent.  相似文献   

18.
19.
高星  李平  吴锦华 《环境工程学报》2014,8(6):2376-2380
采用"混凝-电解氧化-完全混合式活性污泥法(CSTR)"组合工艺深度处理垃圾渗滤液生物处理出水。探索了工艺的组合及各种工艺操作条件对垃圾渗滤液深度处理效果的影响,并对其影响机理进行了初步探讨。结果表明,以PAC为混凝剂时,在pH和药剂(有效成分)投加量分别为6.0和600 mg/L条件下,渗滤液COD去除率达到50%,有效降低了难溶惰性COD含量,缩短了后续电化学处置时间。混凝工艺后,采用电化学工艺处理,在最优工艺条件下:pH为6.0、电流I为1.2 A(电流密度为18.18 mA/cm2)、Cl-投加量为1 000 mg/L、极板距离为2 cm,电解30 min渗滤液COD去除率达到36%,同时,难降解有毒物含量明显降低,渗滤液可生化性TbOD/COD由10%提升至最大值64%。最后采用CSTR处理渗滤液电解出水,系统出水COD、氨氮和色度分别为100~150 mg/L、7~13 mg/L和25倍,为反渗透(RO)工序提供了良好的水质条件。  相似文献   

20.
Zhao X  Zhang B  Liu H  Chen F  Li A  Qu J 《Chemosphere》2012,87(6):631-636
The treatment of the plugboard wastewater was performed by an optimal electrocoagulation and electro-Fenton. The organic components with suspended fractions accounting for 30% COD were preferably removed via electrocoagulation at initial 5 min. In contrast, the removal efficiency was increased to 76% with the addition of H(2)O(2). The electrogenerated Fe(2+) reacts with H(2)O(2) and leads to the generation of (·)OH, which is responsible for the higher COD removal. However, overdosage H(2)O(2) will consume (·)OH generated in the electro-Fenton process and lead to the low COD removal. The COD removal efficiency decreased with the increased pH. The concentration of Fe(2+) ions was dependent on the solution pH, H(2)O(2) dosage and current density. The changes of organic characteristics in coagulation and oxidation process were differenced and evaluated using gel permeation chromatography, fluorescence excitation-emission scans and Fourier transform infrared spectroscopy. The fraction of the wastewater with aromatic structure and large molecular weight was decomposed into aliphatic structure and small molecular weight fraction in the electro-Fenton process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号