首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
A new approach to surface water analysis has been investigated in order to enhance the detection of different organic contaminants in Nathan Creek, British Columbia. Water samples from Nathan Creek were prepared by liquid/liquid extraction using dichloromethane (DCM) as an extraction solvent and analyzed by gas chromatography mass spectrometry method in scan mode (GC-MS scan). To increase sensitivity for pesticides detection, acquired scan data were further analyzed by Automated Mass Spectrometry Deconvolution and Identification Software (AMDIS) incorporated into the Agilent Deconvolution Reporting Software (DRS), which also includes mass spectral libraries for 567 pesticides. Extracts were reanalyzed by gas chromatography mass spectrometry single ion monitoring (GC-MS-SIM) to confirm and quantitate detected pesticides. Pesticides: atrazine, dimethoate, diazinone, metalaxyl, myclobutanil, napropamide, oxadiazon, propazine and simazine were detected at three sampling sites on the mainstream of the Nathan Creek. Results of the study are further discussed in terms of detectivity and identification level for each pesticide found. The proposed approach of monitoring pesticides in surface waters enables their detection and identification at trace levels.  相似文献   

2.
A multiresidue method was assessed for the determination of several pesticides (organochlorine, organophosphorus, pyrethroids, triazole, amidine) using gas chromatography/mass spectrometry. The extraction of pesticides was carried out by liquid-liquid extraction (LLE) and solid-phase extraction (SPE) using two types of columns (CN and C18). The extracts were cleaned by the addition of florisil, the pesticides were separated by capillary column gas chromatography and detected by mass spectrometry in the electron impact mode. The extraction using C18 column provided the best results for most of the analyzed pesticides. The majority of pesticides recoveries from the four fruits and vegetables (apples, pears, tomatoes and pepper) were greater than 60%. Linearity and precision were satisfactory. The estimated limits of detection and limits of quantification ranged from 0.01 to 0.1 mg/kg and from 0.02 to 0.3 mg/kg, respectively. The proposed procedure was found to be useful for the multiresidue analyses of pesticides in agricultural products for routine monitoring programs.  相似文献   

3.
A multiresidue method was assessed for the determination of several pesticides (organochlorine, organophosphorus, pyrethroids, triazole, amidine) using gas chromatography/mass spectrometry. The extraction of pesticides was carried out by liquid-liquid extraction (LLE) and solid-phase extraction (SPE) using two types of columns (CN and C18). The extracts were cleaned by the addition of florisil, the pesticides were separated by capillary column gas chromatography and detected by mass spectrometry in the electron impact mode. The extraction using C18 column provided the best results for most of the analyzed pesticides. The majority of pesticides recoveries from the four fruits and vegetables (apples, pears, tomatoes and pepper) were greater than 60%. Linearity and precision were satisfactory. The estimated limits of detection and limits of quantification ranged from 0.01 to 0.1 mg/kg and from 0.02 to 0.3 mg/kg, respectively. The proposed procedure was found to be useful for the multiresidue analyses of pesticides in agricultural products for routine monitoring programs.  相似文献   

4.
A simultaneous method for quantifying eight metabolites of organophosphate pesticides and pyrethroid pesticides in urine samples has been established. The analytes were extracted using liquid–liquid extraction coupled with WCX solid phase extraction (SPE) cartridges. Eight metabolites were chemically derivatized before analysis using gas chromatography–tandem mass spectrometry (GC–MS–MS). The separation was performed on a HP-5MS capillary column (30 m × 0.25 mm × 0.25 µm) with temperature programming. The detection was performed under electro-spray ionization (ESI) in multiple reaction monitoring (MRM) mode. An internal standard method was used. The extraction solvent, types of SPE cartridges and eluents were optimized by comparing the sample recoveries under different conditions. The results showed that the calibration curves of the five organophosphorus pesticides metabolites were linear in the range of 0.2–200 μg/L (r2 ≥ 0.992) and that of the three pyrethroid pesticides metabolites were linear in the range of 0.025–250 μg/L (r2 ≥ 0.991). The limits of detection (LODs, S/N ≥ 3) and the limits of quantification (LOQs, S/N ≥ 10) of the eight metabolites were 0.008–0.833 μg/L and 0.25–2.5 μg/L, respectively. The recoveries of the eight metabolites ranged from 54.08% to 82.49%. This efficient, stable, and cost-effective method is adequate to handle the large number of samples required for surveying the exposure level of organophosphorus and pyrethroid pesticides in the general population.  相似文献   

5.
The aim of this study was to develop an analytical method for the determination of residues of organophosphorus and carbamate pesticides which are widely used in Tunisia. This method involves a liquid-liquid extraction procedure followed by liquid chromatography tandem mass spectrometry (LC/MS/MS) for the identification and quantification of compounds. Ionization of molecules was performed by the electrospray mode. Multiple reactions monitoring (MRM) was the acquisition mode used for the monitoring of two MS/MS transitions for each compound. The average recoveries obtained, at three different fortification levels, ranged between 65% and 106% for most of the pesticides studied, except for methamidophos (lower than 25%).The linearity of the method was in the range of 5 to 50 μ g/L with a correlation coefficient from 0.995 to 0.999, depending on the analyte. The estimated limit of detection and limit of quantification were 2 μ g/L and 5 μ g/L, respectively. The precision of the analytical procedure was satisfactory and the coefficients of variation, evaluated at three concentration levels were lower than 15% for most pesticides studied. The application of the method was investigated in a population of agricultural workers chronically exposed to various pesticides some of which, such as carbofuran, carbendazim, methomyl and pirimicarb, were detected in some serum samples.  相似文献   

6.
A solid phase extraction and gas chromatography with negative chemical ionization mass spectrometry in scan mode (GC-NCI-MS) method was developed to identify and quantify for the first time low levels of organochlorine pesticides (OCs) in plasma samples of less than 100 microl from wild birds. The method detection limits ranged from 0.012 to 0.102 pg/microl and the method reporting limit from 0.036 to 0.307 pg/microl for alpha, gamma, beta and delta-hexachlorocyclohexane (HCH), heptachlor, aldrin, heptachlor epoxide, endosulfan I, 1,1-dichloro-2,2-bis(p-chlorophenyl)ethylene (p,p'-DDE), dieldrin, endrin, endosulfan-II, endrin-aldehyde and endosulfan-sulfate. Pesticide levels in small serum samples from individual Falco sparverius, Sturnella neglecta, Mimus polyglottos and Columbina passerina were quantified. Concentrations ranged from not detected (n/d) to 204.9 pg/microl for some OC pesticides. All levels in the food web in and around cultivated areas showed the presence of pesticides notwithstanding the small areas for agriculture existing in the desert of Baja California peninsula.  相似文献   

7.
The purpose of this study was to develop an analytical method for the determination of organophosphorus and pyrethroid pesticides in soybean by pressurized liquid extraction (PLE). Two organic solvents, acetone and acetonitrile, were evaluated as extraction solvents. In both cases, the amount of extract was enhanced with increasing extraction temperature. The extracts obtained using acetonitrile were measured by gas chromatography/mass spectrometry after a cleanup process based on the analytical method for the Japanese Positive List System for Agricultural Chemicals Remaining in Foods. The effect of extraction temperature (range: 40– 130°C) on extraction efficiency was evaluated by a recovery study using 21 organophosphorus pesticides and 10 pyrethroid pesticides as target analytes and acetonitrile as the solvent. The results indicated that at 130°C, some organophosphorus pesticides might be degraded, whereas extraction temperatures between 70°C and 100°C were optimal. Next, a prepared sample containing fenitrothion and permethrin was analyzed. Although the sample was not soaked in water prior to analysis, PLE provided analytical results comparable to those obtained by solvent extraction with homogenization. Therefore, PLE is considered a simple and alternative technique for the extraction of organophosphorus and pyrethroid pesticides in soybean.  相似文献   

8.
Abstract

A simple, very efficient method is presented for routine analysis of herbicide Krovar I? (active components bromacil and diuron) in water and soil samples. Water samples were extracted by liquid–liquid extraction with dichloromethane (DCM) as extraction solvent. For soil samples two different extraction techniques were compared: microwave-assisted solvent extraction and a shaking technique using a platform shaker. Extracts were analyzed by high performance liquid chromatography using a water:methanol gradient. Liquid chromatography was coupled with atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS) for quantification of bromacil and diuron. Optimization of the APCI-MS was done by using standards in the flow injection analysis mode (FIA). Method detection limit for liquid samples for bromacil is 0.04 µg L?1 and for diuron 0.03 µg L?1. Method detection limit for soil samples is 0.01 µg g?1 dry weight for both compounds. Results of analysis of field samples of water and soil are also presented.  相似文献   

9.
A rapid, sensitive, accurate and reliable multiresidue method for the identification and quantification of 210 relevant pesticides in four representative fruit and vegetable commodities (tomato, potato, spring onion and orange) has been developed and validated by gas chromatography in tandem with triple quadrupole mass spectrometry. The method has been fully validated and applied to 292 samples from different countries. Prior to instrumental analysis, an extraction procedure based on a sample extraction of multiclass analytes, using the ethyl acetate method was employed. Mass spectrometric conditions were individually optimized for each compound in the selected reaction monitoring (SRM) mode to achieve maximum sensitivity. The pesticides were separated in less than 25 min. This was followed by an exhaustive control of the retention times. The Retention Time Locking Method was applied, working at a constant pressure throughout the analysis. System maintenance was reduced by using a purged capillary flow device that provided backflush capabilities by reversing column flow immediately after elution of the last compound of interest. Istotopically labelled internal standards were employed to improve the quality of the analytical results.  相似文献   

10.
Abstract

Terbufos sulfoxide is a primary metabolite of the organophosphorus insecticide terbufos. The identification of terbufos sulfoxide was determined by combined gas chromatography/mass spectrometry and the direct probe. Mass spectral data are presented and discussed. The data indicate that thermal degradation occurred in the heated GC column. A hydration product of terbufos sulfoxide was detected and its mass spectral data are discussed.  相似文献   

11.
A simple, sensitive, reliable method was developed for the simultaneous determination of organochlorine and pyrethriod pesticide residues in Chinese patent medicines Six ingredient rehmannia pills and Xiaoyao pills. These pesticides were extracted by ethyl acetate. The extraction time and volume of ethyl acetate were optimized. Cleanup of extracts was performed with dispersive-solid phase extraction using graphitized carbon black as the sorbent. The determination of pesticides in the final extracts was carried out by gas chromatography–tandem mass spectrometry in multiple reaction monitoring mode (GC-MS/MS, MRM). The linearity of the calibration curves is good in matrix-matched standard and yields the coefficients of determination (R2) ≥0.99 for all of the target analytes. Under optimized conditions, the average recoveries (five replicates) for most pesticides range from 75.5% to 114.6%, and RSDs are less than 10.0%. The LODs of 18 pesticides in Six ingredient rehmannia pill and Xiaoyao pills are in the range of 0.01–8.82 μg kg?1. The developed method meets the requirements of pesticide residue analysis and could be effectively used for routine analysis of the organochlorine and pyrethriod pesticide residues in Six ingredient rehmannia pills and Xiaoyao pills.  相似文献   

12.
An analytical method was developed for determining organophosphate pesticides (OPP) and pyrethroid pesticides (PYR) in duplicate-diet solid food. The method consisted of pressurized liquid extraction (PLE) with dichloromethane followed by cleanup with gel permeation and solid phase extraction columns and gas chromatography/mass spectrometry (GC/MS) analysis. Quantitative recoveries (73–117 %) of the target pesticides were obtained for spiked duplicate-diet food samples. The percent standard deviation (% RSD) of replicate food samples was within ± 20 %. Another method was developed for determining a common OPP metabolite, 3, 5, 6-trichloro-2-pyridinol (TCP) in duplicate-diet food. The method consisted of a PLE with methanol followed by liquid-liquid partitioning, derivatization, and GC/MS analysis. Recoveries of TCP ranged from 83 to 101 % for spiked duplicate-diet food samples. The % RSD of replicate food samples was within ± 15 %. The results confirmed that these methods are reliable and robust, and that they can be used in routine analysis. In addition, a storage stability study for a common OPP, chlorpyrifos (CPF), in solid food samples was performed. The fortified 15N-13C-labeled CPF was stable over 16 mo storage at ?20° C in the dark. The developed analytical methods were successfully applied to 278 duplicate-diet food samples from preschool children, demonstrating that these methods are robust and suitable for routine analysis in future exposure monitoring studies.  相似文献   

13.
The purpose of this study was to develop an analytical method for the determination of organophosphorus and pyrethroid pesticides in soybean by pressurized liquid extraction (PLE). Two organic solvents, acetone and acetonitrile, were evaluated as extraction solvents. In both cases, the amount of extract was enhanced with increasing extraction temperature. The extracts obtained using acetonitrile were measured by gas chromatography/mass spectrometry after a cleanup process based on the analytical method for the Japanese Positive List System for Agricultural Chemicals Remaining in Foods. The effect of extraction temperature (range: 40- 130°C) on extraction efficiency was evaluated by a recovery study using 21 organophosphorus pesticides and 10 pyrethroid pesticides as target analytes and acetonitrile as the solvent. The results indicated that at 130°C, some organophosphorus pesticides might be degraded, whereas extraction temperatures between 70°C and 100°C were optimal. Next, a prepared sample containing fenitrothion and permethrin was analyzed. Although the sample was not soaked in water prior to analysis, PLE provided analytical results comparable to those obtained by solvent extraction with homogenization. Therefore, PLE is considered a simple and alternative technique for the extraction of organophosphorus and pyrethroid pesticides in soybean.  相似文献   

14.
ABSTRACT

In order to evaluate the existing risk to public health in Arizona related to hazardous air pollution, ambient air monitoring for selected hazardous air pollutants (HAPs) was carried out in 1994-1996 in several representative urban and rural areas of Arizona. A wide range of organic HAPs was monitored, requiring a variety of sampling and analysis methods. Stainless steel SUMMA canisters were used for collection of volatile hydrocarbons and halocarbons, which were analyzed by capillary gas chromatography with flame ionization and electron capture detection (GC-FID/ECD). Carbonyl compounds were collected using 2,4-dinitrophenylhydrazine-impregnated cartridges and analyzed by high performance liquid chromatog-raphy with ultraviolet detection. Semi-volatile and non-volatile polycyclic aromatic compounds were collected using a sampling train consisting of a filter followed by a PUF/XAD-4/PUF sandwich cartridge. Following extraction, samples were analyzed by capillary GC with mass spectrometric detection (GC-MS). Database software was developed for data processing and reporting functions. This paper describes the sampling strategy and the sampling and analysis methods employed in the monitoring program and presents a summary of all the results obtained during the duration of the sampling program.  相似文献   

15.
Abstract

The evaluation of emissions of volatile organic compounds (VOCs) during processing of resins is of interest to resin manufacturers and resin processors. An accurate estimate of the VOCs emitted from resin processing has been difficult due to the wide variation in processing facilities. This study was designed to estimate the emissions in terms of mass of emitted VOC per mass of resin processed.

A collection and analysis method was developed and validated for the determination of VOCs present in the emissions of thermally processed acrylonitrile butadiene styrene (ABS) resins. Four composite resins were blended from automotive, general molding, pipe, and refrigeration grade ABS resins obtained from the manufacturers. Emission samples were collected in evacuated 6-L Summa canisters and then analyzed using gas chromatography/flame ionization detection/mass selective detection (GC/FID/MSD). Levels were determined for nine target analytes detected in canister samples, and for total VOCs detected by an inline GC/FID. The emissions evolved from the extrusion of each composite resin were expressed in terms of mass of VOCs per mass of processed resin. Styrene was the principal volatile emission from all the composite resins. VOCs analyzed from the pipe resin sample contained the highest level of styrene at 402 μg/g. An additional collection and detection method was used to determine the presence of aerosols in the emissions. This method involved collecting particulates on glass fiber filters, extracting them with solvents, and analyzing them using gas chromatography/mass spectrometry (GC/MS). No significant levels of any of the target analytes were detected on the filters.  相似文献   

16.
文中综述了多氯联苯的分析技术及其研究进展。介绍了样品前处理技术如索氏萃取法、超声萃取法、微波辅助萃取、超临界流体萃取、加速溶剂萃取等在土壤样品中多氯联苯分析中的应用;阐述了气相色谱、液相色谱、气质联用技术在土壤样品中多氯联苯的检测,并对土壤中未来多氯联苯检测技术的发展提出了展望。  相似文献   

17.
The Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method was applied to the extraction of 14 organochlorine pesticides (OCPs) residues from commercial fruit pulps available in supermarkets in Fortaleza, Northeastern Brazil. The analyses were carried out by gas chromatography (GC), coupled to an electron-capture detector (ECD), and were confirmed by GC-tandem mass spectrometry (MS). The parameters of the analytical method, such as accuracy, precision, linear range, limits of detection and quantification, were determined for each pesticide. The results showed good linearity (R2 ≥ 0.9916) and the overall average recoveries were considered satisfactory obtaining values between 69 and 110%, RSD of 2–15 %, except for hexachlorobenzene (HCB) in açai, acerola and guava pulp samples. The OCPs were detected in guava (α–HCH; lindane) and soursop (α, β–HCH isomers) samples. The QuEChERS method and GC–ECD were successfully used to analyze OCPs in commercially available Brazilian fruit pulps and can be applied in routine analytical laboratories.  相似文献   

18.
ABSTRACT

In order to characterize typical indoor exposures to chemicals of interest for research on breast cancer and other hormonally mediated health outcomes, methods were developed to analyze air and dust for target compounds that have been identified as animal mammary carcinogens or hormonally active agents and that are used in commercial or consumer products or building materials. These methods were applied to a small number of residential and commercial environments to begin to characterize the extent of exposure to these classes of compounds. Phenolic compounds, including nonylphenol, octylphenol, bisphenol A, and the methoxychlor metabolite 2,2-bis (p-hydroxyphenyl)-1,1,1-trichloroethane (HPTE), were extracted, derivatized, and analyzed by gas chromatography/mass spectrometry (GC/MS)–selective ion monitoring (SIM). Selected phthalates, pesticides, polycyclic aromatic hydrocarbons (PAHs), and polychlorinated biphenyls (PCBs) were extracted and analyzed by GC/MS-SIM. Residential and workplace samples showed detectable levels of twelve pesticides in dust and seven in air samples. Phthalates were abundant in dust (0.3524 μg/g) and air (0.005-2.8 μg/m3). Nonylphenol and its mono- and di-ethoxylates were prevalent in dust (0.82-14 μg/g) along with estrogenic phenols such as bisphenol A and o-phenyl phenol. In this 7-sample pilot study, 33 of 86 target compounds were detected in dust, and 24 of 57 target compounds were detected in air. In a single sample from one home, 27 of the target compounds were detected in dust and 15 in air, providing an indication of chemical mixtures to which humans are typically exposed.  相似文献   

19.
Abstract

A saponification extraction method with gas chromatography pseudo-MRM (pMRM) mass spectrometry detection was developed for the determination of 50 total polycyclic aromatic hydrocarbons (TPAH50, a combination of parent and alkylated homologues) in biota. The method was aimed at monitoring and identification of potential TPAH contaminants in bitumen impacted environments. Alkylated PAHs were determined by multi-level, quantitative calibration using parent PAHs. The developed and thoroughly validated method required only one injection for TPAH50 analysis which represents significant saving of time and expensive authentic alkylated standards. The current method was tested with certified reference mussel tissue NIST 1974c and performed well. In a comparison study, the method reached a limit of quantitation (LOQ) for the TPAH50 between 0.1 and 0.2?ng g?1, while the QuEChERs enhanced matrix removal – lipid (EMR) kit produced by Agilent showed an LOQ of 5–10?ng g?1. The current method relied on response factors (RF) for the quantitation of alkylated PAHs determined against parent PAHs. These RFs were shown to be stable and consistent over the course of 1 year, during which over 200 routine environmental biota monitoring samples were analyzed. The environmental biota monitoring samples analyzed include muscle, carcass and liver, with an average total PAH50 concentration of 13, 90 and 135?ng g?1, respectively. Results show significant differences in the distributions of 1 ringed, 2 ringed, 3 ringed, 4 ringed, and 5+ ringed TPAHs between the types of biota samples.  相似文献   

20.
To collect a complete dataset regarding the occurrence of organic substances in groundwater, this study presents the examination of 66 organic contaminants in the groundwater of overseas departments, including pesticides, pharmaceutical compounds, hormones and some industrial substances. The selective and sensitive analytical methods are described. These techniques begin with solid-phase extraction (SPE) followed by analysis using liquid chromatography–tandem mass spectrometry (LC-MS/MS) and gas chromatography–mass spectrometry (GC-ToF-MS). The paper summarises the analytical results from 40 sampling points collected during two campaigns in Guadeloupe, Martinique, Reunion, Mayotte and Guiana, representing 80 samples. Of the 66 target substances, 36 were determined at least once. Among the most frequently detected are bisphenol A (frequency, 96 %; max., 7,400 ng/L), caffeine (frequency, 91 %; max., 1,240 ng/L), pentachlorophenol (frequency, 55 %; max., 418 ng/L), and carbamazepine (frequency, 56 %; max., 22 ng/L). The results do not put in evidence that the origin of the sample or climatic characteristics of these regions influence the dilution and release of micropollutants.  相似文献   