首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The Sequencing Batch Reactor (SBR) system employing activated sludge process is an alternative wastewater treatment technology. A cycle of the conventional SBR system generally consists of five periods, with complete aeration during the React period to oxidize the organic matter and nitrify the ammonium-nitrogen of wastewater. Laboratory-scale reactors were used to evaluate the feasibility of incorporating alternative aerobic-anoxic-aerobic stages within the React period for simultaneous removal of organic matter, N and P. Two cycles of SBR process per day were maintained.Under the operation strategy of 0.75-h fill, 8-h react (with continuous aeration), 3.25-h settle, draw and idle periods, the treatment performance became consistent after running the system for two to four cycles (1–2 days). The percentages of both BOD5 and COD removal were around 94% from Cycle 2 onwards, the BOD5 content dropped from initial 251 mg L−1 to less than 14 mg L−1 in the final effluent. A steady nitrification (about 97%) was obtained from Cycle 4 onwards, with 1 mg NH4+-N L−1 and 25 mg NO3-N L−1 present in the final effluent. This suggested that the time required for SBR system to acclimate and reach an equilibrium state was relatively short when compared with the time needed for continuous flow activated sludge system. The findings also show that 4-h aeration during the react period was long enough to achieve more than 90% nitrification. With the incorporation of a 3-h anoxic stage after the initial 4-h aeration of the react period, a satisfactory denitrification process was observed, with nitrate level dropped from 27 to around 8 mg L−1 within 3 h. The second aeration stage did not cause significant change in wastewater nitrogen content. The wastewater phosphate content declined rapidly during the initial 4-h aeration and P-release was not observed during the anoxic stage. A slight reduction of P was found in the second aeration stage suggesting that more P-uptake occurred in this stage. A 12-h cyclic SBR system with the incorporation of 4-h aerobic, 3-h anoxic and final 1-h aerobic stages into the 8-h react period was demonstrated to be able to remove C, N and P simultaneously.  相似文献   

2.
The production of highly polluting palm oil mill effluent (POME) has resulted in serious environmental hazards. While anaerobic digestion is widely accepted as an effective method for the treatment of POME, anaerobic treatment of POME alone has difficulty meeting discharge limits due to the high organic strength of POME. Hence, subsequent post-treatment following aerobic treatment is vital to meet the discharge limits. The objective of the present study is to investigate the aerobic treatment of anaerobically digested POME by using a sequencing batch reactor (SBR). The SBR performance was assessed by measuring Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD) and Total Suspended Solids (TSS) removal as well as Sludge Volume Index (SVI). The operating pH and dissolved oxygen concentrations were found to be 8.25–9.14 and 1.5–6.4 mg/L, respectively, throughout the experiment. The experimental results demonstrate that MLVSS, OLR and sludge loading rate (SLR) play a significant role in the organic removal efficiency of SBR systems and therefore, further investigation on these parameters was conducted to attain optimum SBR performance. Maximum COD (95–96%), BOD (97–98%) and TSS (98–99%) removal efficiencies were achieved at optimum OLR, SLR and MLVSS concentration ranges of 1.8–4.2 kg COD/m3 day, 2.5–4.6 kg TSS/m3 day and 22,000–25,000 mg/L, respectively. The effluent quality remained stable and complied with the discharge limit. At the same time, the sludge showed good settling properties with average SVI of 65. It is envisaged that the SBR process could complement the anaerobic treatment to produce final treated effluent which meets the discharge limit.  相似文献   

3.
ABSTRACT: Water hyacinth (Eichhornia crassipes L.) has shown to be effective in the treatment of municipal wastewater in a pilot study begun in January 1989 by the Pima County Wastewater Management Department and researchers associated with The University of Arizona's Office of Arid Lands Studies in the Sonoran Desert near Tucson. The influent pumped into the pilot facility's six raceways (ponds) typically has been treated secondary effluent diverted from a conventional treatment facility, although primary effluent from the same facility also has been treated. The Secondary Influent Treatment System has met the Arizona Department of Environmental Quality (ADEQ) tertiary standard for BOD5 and TSS of 10 mg/l for every month of its operation since March 1990; the Primary Influent Treatment System met the ADEQ secondary standard for BOD5 and TSS of 30 mg/1 for most of the 10 months it was in operation.  相似文献   

4.
Studies have been made of the growth characteristics of water hyacinth, Eichhornia crassipes (Mart.) Solms, and its ability to remove N, P and K, in a secondary settling pond of a small secondary sewage treatment plant serving both the academic and residential blocks of the Swire Marine Laboratory, University of Hong Kong. The treatment plant consists of, in series, a primary settling tank, a trickling filter compartment and a secondary settling pond from which part of the treated wastewater is recycled to the primary settling tank while the remaining effluent (1 to 2 m3 daily) mixes with and hence is diluted by the outflowing seawater from the aquarium system of the Swire Marine Laboratory before discharge to the sea. Samples of wastewater have been taken regularly from the primary sedimentation pond, the outflow of the trickling filter, the secondary settling pond and the effluent of the treatment plant (before mixing with aquarium outflow) since January, 1992. Physical, chemical and biological characteristics of the samples have been determined and are typical of secondary effluents, with a mean pH of about 7.5, total solids 1200 mg L−1, suspended solids 45 mg L−1, conductivity 2000 μS cm−1, salinity 1 ppt, dissolved oxygen 2 mg L−1, BOD5 45 mg L−1, Kjeldahl-N 30 mg L−1, NH4,-N 25 mg L−1, NO3-N 4 mg L−1, total P 10 mg L−1, K 35 mg L−1 and total coliforms of less than 105 colonies 100 ml−1.Water hyacinth plants have been stocked in the secondary settling pond as an integral part of the treatment plant so as to improve the quality of, as well as to retrieving and recycling nutrient elements from, the wastewater. The plants are periodically harvested to maintain an active growing crop. The growth rate, standing crop biomass, tissue nutrient composition, nutrient storage and accumulation rate of two growth cycles, one from February 25 to March 18 (mean temperature 17.6°C) and the other from 22 April to 12 May (24.8°C) are reported. The water hyacinth assumed a relatively high standing crop biomass of 10 kg m−2 (5 to 6 t DM ha−1), and growth rates of 48 and 225 g m−2 day−1, respectively, for the first and second growth period. Nutrient storage capacities were relatively high, at about 20, 7.5 and 16.5 g m−2 for N, P and K, respectively. The nutrient composition was very high, reaching 5.42% for N, 1.97 for P, and 4.57 for K. Both the stem and lamina accumulated high levels of N, while the petiole had the highest level of P and K. Apart from nutrient removal, the water hyacinth also helped to decrease the suspended solids, BOD5 value and total coliforms of the wastewater.It is concluded that water hyacinth improves the quality of wastewater in such small-scale sewage treatment plants and it is recommended that frequent harvests of water hyacinth would increase the treatment efficiency, especially during the active growing season with high temperatures coupled with intense solar radiation.  相似文献   

5.
Summary This study is carried out to propose an appropriate treatment technology for wastewater discharged from a flavor production factory. Industrial wastewater discharged from this factory ranges between 50–70 m3/d with an average value of 60 m3/d. The major source of pollution in this factory is due to cleaning of the vessels therefore the treatment has been carried out on the end-of pipe wastewater. The wastewater is characterized by high values of COD, BOD, TSS and Oil and grease 4646, 2298, 1790 and 626 mg/l respectively. Primary sedimentation of the wastewater for four hours reduced the COD, BOD, TSS and Oil and grease by 43, 47, 80 and 74%, respectively. For the treatment of the produced wastewater, the biological treatment process such as activated sludge, rotating biological contactor (RBC), up-flow anaerobic sludge bed reactor (UASB) have been selected. The results from each treatment process proved to be efficient for the treatment of such wastewater. The treated wastewater characteristics are in compliance with the Egyptian law which regulates the discharge of industrial wastewater to the sewerage system. The RBC was selected and installed by the factory as it has the advantage of low operating and maintenance costs. The factory RBC performance was monitored; characteristics of the treated effluent in terms of oil and grease, COD, BOD and TSS were 27, 362, 139 and 95 mg/l, respectively.  相似文献   

6.
Regeneration studies of wastewater effluent from an organized industrial district (OID) for possible reuse in textile industry as process water was investigated. Advanced treatment methods including Fenton process, polyaluminium chloride (PAC) coagulation and ion exchange were applied on OID effluent. In Fenton process removal efficiencies for suspended solids (SS), chemical oxygen demand (COD), SAC436 (spectral absorption coefficient), SAC525 and SAC620 were determined 61%, 36%, 35%, 49% and 67%, respectively. After Fenton process, wastewater samples were coagulated with PAC. Optimum removal efficiencies for SS, COD, Fe ion, SAC436, SAC525 and SAC620 were determined 83%, 18%, 93%, 32%, 36% and 58%, respectively. Ion exchange experiments were conducted on chemically coagulated wastewater samples to improve the quality of wastewater. Optimum dosage of resins was determined. The experiments revealed that 1:1 resin ratio (20 mL H-type resin:20 mL OH-type resin) gave the best removal rates for the parameters considered in this study. Study results indicated that quality of the wastewater was suitable for the process water characteristics of textile industry and unit wastewater treatment cost was determined as 2.54 €/m3.  相似文献   

7.
Overland flow (OF) systems were evaluated and compared for advanced treatment of municipal and industrial effluents, including nutrients and nondegradable chemical oxygen demand (COD) removal. Three pilot plants were constructed at the Shahin Shahr Wastewater Treatment Plant (WWTP), Isfahan, Iran. Each pilot was assigned a specific wastewater and all were simultaneously operated for 8 months. Treatment of primary effluent, activated sludge secondary effluent, and lagoon effluent of textile wastewater was investigated at application rates (ARs) of 0.15, 0.25, and 0.35m(3)m(-1)h(-1). During 5 months of stable operation after a 3-month acclimation period, mean removals of total 5-day biochemical oxygen demand (TBOD(5)), total COD (TCOD), total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and turbidity were 74.5%, 54.8%, 66.2%, 39.4%, 35.8%, and 67.7% for primary effluent; 52.9%, 52.9%, 66.5%, 44.4%, 39.8%, and 50.1% for activated sludge effluent; 65.7%, 58.7%, 70.3%, 41.7%, 41.3%, and 54.9% for textile wastewater lagoon effluent, respectively. The model of Smith and Schroeder, 1985. Field studies of the overland flow process for the treatment of raw and primary treated municipal wastewater. Journal of Water Pollution Control Federation 57, 785-794] was satisfactory for TBOD(5). For all treatment parameters a standard first-order removal model was inadequate to represent the data but a modified first-order model provided a satisfactory fit to the data. Based on the results of this study, it can be concluded that an OF system as advanced treatment had the ability to meet effluent discharge permit limits and was an economical replacement for stabilization ponds and mechanical treatment options.  相似文献   

8.
An integrated investigation on wastewater characterization and the environmental effects from the COGIDO pulp and paper mill in Bien Hoa Industrial Estate, Vietnam, a chlorine bleached soda integrated pulp and paper mill operating without a chemical recovery system, on the receiving water body was conducted during the rainy and dry seasons in 1993 and 1995. The pollution load from the mill was very high in terms of BOD, COD and SS (CODm: 58.7 t/d; BOD: 33.3 t/d and SS: 25.1 t/d). The effluent toxicity was determined using four toxicity tests: the green micro-alga, Selenastrum capricornutum, Microtox (marine bacteria: Photobacterium phosphoreum), the duckweed, Lemna aequinoctialis, and fish (silver barb: Puntius gonionotus, and Tilapia: Tilapia nilotica). Selenastrum capricornutum was the most sensitive among the tested organisms. The mill toxicity emission rate (TER) was as high as 338 610 (Selenastrum test). The bleaching-pulp and semi-chemical pulp plants which contributed the largest pollution load to the total COGIDO effluent, therefore, were targeted for abatement measures. Physico-chemical parameters as well as qualitative and quantitative aquatic organism composition for the river water were established. The BOD5 and COD values exceeded the potable surface water standard by a factor of 2 to 4. The species diversity and abundance of the phytoplankton, zooplankton and zoobenthos were found to be lower (20–40%) than that of unpolluted rivers in Vietnam, whereas pollution-indicator species increased up to four times during the dry season 1995.  相似文献   

9.
ABSTRACT: Wetlands that treat holding pond effluent can be designed to utilize the pond storage capacity to allow flexibility in system management. Management of a wetland as a sequencing batch reactor can simplify operation and control detention times, but little performance data on such systems are available. The objective of this study was to evaluate the batch reactor wetland concept by quantifying removal of chemical oxygen demand (COD), total suspended sediments (TSS), total nitrogen (TN), ammonium (NH4), nitrate (NO3), total phosphorus (TP), and orthophosphate (PO4) and by assessing the suitability of first‐order kinetics. Weekly samples were collected following batch loadings of wetland cells with high concentration or low concentration dairy holding pond wastewater during both fall and spring seasons. During three‐week batch periods without plants, overall mass removal averaged 54 percent for COD, 58 percent for TSS, 90 percent for TN, 72 percent for NH4, ‐54 percent for NO3, 38 percent for TP, and ‐8 percent for PO4. Best fit, first‐order kinetic rate constant (k) and background concentration (C*) for COD varied by season, with k = 0.024/d and C*= 0 mg/l in fall and k = 0.056/d and C*= 200 mg/l in spring. Ammonium exhibited a consistent C*= 0 mg/l but had variable rate constants of k = 0.121/d for low concentration treatments and k = 0.079/d for high concentration treatments. Using first‐order kinetics was also appropriate for TN, with k = 0.061/d and C*= 0 mg/l for all loadings and seasons, but was not consistently appropriate for TP or PO4. These results support the use of first‐order kinetics to describe treatment in batch reactor wastewater treatment wetlands without vegetation, perhaps during the establishment phase or in open water zones of vegetated wetlands. Further work is needed to assess the effects of vegetation.  相似文献   

10.
Anaerobic/aerobic treatment of meat processing wastewater   总被引:2,自引:0,他引:2  
The meat processing industry is believed to produce highly polluted wastewater. Analysis of such wastewater indicated that the waste was highly contaminated with organic compounds as indicated by COD (1544mgO2l–1), BOD (646mgO2l–1), and TSS (1155 mgl–1). Moreover, oil and grease concentrations reached 144mgl–1 treatment of raw wastewater using Upflow Anaerobic Sludge Blanket (UASB) followed by Rotating Biological Contactors (RBC) was studied. Efficiency of the UASB for the removal of CODtotal, BODtotal, TSS, and oil and grease was 56%, 56%, 85%, and 58%, respectively. The quality of the UASB effluent barely complies with the regulatory standards for discharging wastewater into the sewerage network. UASB effluent was subjected for further treatment using a RBC unit to improve the quality of the treated effluent for reuse in irrigation purposes. Residual COD, BOD, TSS, and oil and grease, following RBC, was 132mgO2l–1, 40mgO2l–1, 44mgl–1, and 10mgl–1 respectively. The overall efficiency of the treatment units provided good quality effluent. The overall percentage removal of COD, BOD, TSS, and oil and grease was 91.5%, 94%, 96%, and 91%, respectively. Based on the quality of the treated effluent and guidelines recommended for wastewater reuse, it may be concluded that a slight to moderate restricted irrigation is applicable to reuse the treated effluent in the green belt around the factory. Disinfection should be applied to ensure the safety of such a process.  相似文献   

11.
ABSTRACT: The use of peatlands as the main form of wastewater treatment in a northern climate was studied for the James Bay Energy Society. The Fontanges campsite (70° 17′ 30″ W; 54° 34′ 00″ N) was chosen as the study site. In less than 1.5 km from the point of discharge BOD5, COD, total hardness, inorganic carbon, orthophosphates, total phosphorus, ammonia and total nitrogen were reduced by at least 90 percent. The peatland treatment system studied is divided into four components, each having a specific function. The first part combines the action of microorganisms and adsorption on peat, thus reducing the organic content while increasing the inorganic constituents. The second part uses peat to adsorb the inorganic elements already present in the wastewater and those produced in the first part of the system. The third component acts as an aerator, increasing the dissolved oxygen and decreasing the BOD5 levels of the water. The fourth part removes most of the remaining nutrients, thus acting like a tertiary treatment. Overall, peatlands seemed to be effective in treating domestic settled wastewater in a cold climate.  相似文献   

12.
A conventional activated sludge treatment facility was the subject of this study. The assessment was directed at determining the characteristics of the raw wastewater, the quality of the treated effluent and the efficiency of the various treatment units. Furthermore, the water quality along the effluent irrigation canal was monitored. The assessment of the quality of the treated effluent for irrigation is based on the guidelines established by the World Health Organization and the Egyptian decree 9/89 for the use of wastewater in agriculture. The results of the study indicated that the concentration of the raw wastewater was considered moderate. The mean values of the COD (Chemical Oxygen Demand), BOD (Biological Oxygen Demand) and total suspended solids (TSS) were around 250, 102 and 142 mg l–1, respectively. This was attributed to the high quantities of wastewater from industrial sources. The overall efficiency of the treatment facility was good. The mean residual COD, BOD and TSS were 25, 8 and 21 mg l–1 and the corresponding percentage removal values were 90, 92 and 85%, respectively. The maximum percentage removal of oil and grease was 84% with a mean residual concentration of 24 mg l–1. The total viable count (22°C and 37°C), faecal coliform and aecal streptococci were reduced by 99.9% compared to only 99.5% for Salmonella. Bacteriological examination of the dried sludge indicated a reduction of nine logs of faecal coliform and faecal streptococci, as compared to thickened sludge. Analysis of the Ni, Cu, Pb and Cr in the dried sludge indicated that their concentrations are within the permissible limits. Zinc exceeded the consent standards by 50%. The results of the analyses of samples collected at the beginning of the irrigation canal indicated insignificant changes from the characteristics of the final effluent. Samples collected at a distance of 2km along the irrigation canal showed mean reductions in the COD and BOD of 28.6 and 47%, respectively, which could be attributed to sedimentation and/or a self-purification effect. An increase in the total nitrogen, total phosphorus and total viable count was also recorded, which could be due to seepage from the agricultural land. From the data available it is evident that the treated wastewater could be used for restricted irrigation. The design and implementation of a monitoring programme is recommended.  相似文献   

13.
The water disinfecting behavior of silver-modified clinoptilolite–heulandite rich tuff (ZSAg) as an antibacterial agent against coliform microorganisms from water in a continuous mode was investigated. Silver recovery from the disinfected effluents by the sodium-modified clinoptilolite–heulandite rich tuff (ZSNa) was also considered. Escherichia coli (ATCC 8739) and total coliform microorganisms, as indicators of microbiological contamination of water, were chosen to achieve the disinfection of synthetic wastewater or municipal wastewater. Ammonium (NH4+) and chloride (Cl) ions were added to the synthetic wastewater as an interfering chemical species on the disinfection processes. The antibacterial activity of the ZSAg as a bactericide was measured by the coliform concentration as evaluated by the APHA method. The amount of silver in the disinfected effluents was determined using atomic absorption spectroscopy. The inactivation of the ZSAg was calculated from the breakthrough curves based on the model reported by Gupta et al. It was found that when the silver concentration in the effluent is less than 0.6 μg/mL, the bacterial survival percentage increased and the volume of disinfected water diminished. The total silver amounts found in the effluent at the end of the disinfection processes varied depending on the water treated (synthetic or municipal wastewater). The presence of NH4+ ions in synthetic wastewater influent notably improved the disinfected water volume (zero NVC/100 mL), in comparison to the disinfection of the same influent without NH4+ ions. A contrary water disinfection behavior was observed in the presence of Cl ions. The silver recovery does not depend on the mass of the sodium zeolitic bed according with the wastewater to be treated (synthetic or municipal wastewater) and the presence of NH4+ or Cl ions in the influent also influenced the silver recovery from wastewater. The ZSNa did not have antibacterial activity. Therefore the amount of bactericide agent (silver-modified natural zeolite), coliform microorganisms from water (E. coli or consort of coliform microorganisms) as well as the water quality (synthetic wastewater or municipal wastewater) influenced both the disinfection process and the silver recovery in a column system.  相似文献   

14.
This study analyzes and compares the results of leachate composition at the semi-aerobic Pulau Burung Landfill Site (PBLS) (unaerated pond and intermittently aerated pond) and the anaerobic Kulim Sanitary Landfill in the northern region of Malaysia. The raw samples were collected and analyzed for twenty parameters. The average values of the parameters such as phenols (1.2, 6.7, and 2.6 mg/L), total nitrogen (448, 1200, and 300 mg/L N-TN), ammonia-N (542, 1568, and 538 mg/L NH3-N), nitrite (91, 49, and 52 mg/L NO2?-N), total phosphorus (21, 17, and 19 mg/L), BOD5 (83, 243, and 326 mg/L), COD (935, 2345, and 1892 mg/L), BOD5/COD (0.096,0.1124,0.205%), pH (8.20, 8.28, and 7.76), turbidity (1546, 180, and 1936 Formazin attenuation units (FAU)), and color (3334, 3347, and 4041 Pt Co) for leachate at the semi-aerobic PBLS (unaerated and intermittently aerated) and the anaerobic Kulim Sanitary Landfill were recorded, respectively. The obtained results were compared with previously published data and data from the Malaysia Environmental Quality Act 1974. The results indicated that Pulau Burung leachate was more stabilized compared with Kulim leachate. Furthermore, the aeration process in PBLS has a considerable effect on reducing the concentration of several pollutants. The studied leachate requires treatment to minimize the pollutants to an acceptable level prior to discharge into water courses.  相似文献   

15.
To reduce the consumption of freshwater in the laundry industry, a new trend of closing the water cycle has resulted in the reuse/recycling of water. In this study, the performance of a full-scale submerged aerobic membrane bioreactor (9 m3) used to treat/reuse industrial laundry wastewater was examined over a period of 288 days. The turbidity and total solids (TS) were reduced by 99%, and the chemical oxygen demand (COD) effluent removal efficiencies were between 70% and 99%. The levels of COD removed by the membrane were significantly greater than the levels of biodegraded COD. This enabled the bioreactor to sustain COD levels that were below 100 mg/L, even during periods of low wastewater biodegradation due to bioreactor sludge. An economic evaluation of the membrane bioreactor (MBR) system showed a savings of 1.13 € per 1 m3 of water. The payback period for this system is approximately 6 years. The energy and maintenance costs represent only 5% of the total cost of the MBR system.  相似文献   

16.
Earthworms’ body works as a ‘biofilter’ and they have been found to remove the 5 days’ BOD (BOD5) by over 90%, COD by 80–90%, total dissolved solids (TDS) by 90–92%, and the total suspended solids (TSS) by 90–95% from wastewater by the general mechanism of ‘ingestion’ and biodegradation of organic wastes, heavy metals, and solids from wastewater and also by their ‘absorption’ through body walls. Earthworms increase the hydraulic conductivity and natural aeration by granulating the clay particles. They also grind the silt and sand particles, increasing the total specific surface area, which enhances the ability to ‘adsorb’ the organics and inorganic from the wastewater. Intensification of soil processes and aeration by the earthworms enable the soil stabilization and filtration system to become effective and smaller in size. Suspended solids are trapped on top of the vermifilter and processed by earthworms and fed to the soil microbes immobilized in the vermifilter. There is no sludge formation in the process which requires additional expenditure on landfill disposal. This is also an odor-free process and the resulting vermifiltered water is clean and disinfected enough to be reused for farm irrigation and in parks and gardens G. Bharambe—GU & Research Assistant (Under Rajiv K. Sinha), U. Chaudhari—GU (Worked on vermiculture project).  相似文献   

17.
为探讨香港水质管理的措施及效果,本文对香港吐露港地区5条河流10个监测点1985—2014年的地表水质数据进行分析,观察水体整治管理前后污染物浓度的变化。结果表明:10个监测点的氨氮、BOD_5、COD和TP的浓度均逐年下降,上下游共同努力,使各项污染物得到很大程度的削减,并且治理前后的浓度存在明显统计学差异(p0.05),且治理之后各项污染物年均浓度趋于平稳,达到标准以内。由此可以看出,香港地区水质管理效果的显著与其所实施的《水污染管制条例》、禽畜饲养禁制区设立与吐露港及牛尾海污水收集整体计划密不可分。随着国务院颁布的《水污染防治行动计划》的施行,香港吐露港地区治理的措施可为我国现阶段黑臭水体整治工作所借鉴。  相似文献   

18.
ABSTRACT: Application of fertilizer can degrade quality of runoff, particularly during the first post-application, runoff-producing storm. This experiment assessed and compared runoff quality impacts of organic and inorganic fertilizer application for a single simulated storm occurring seven days following application. The organic fertilizers used were poultry (Gallus gallus domesticus) litter, poultry manure, and swine (Sus scrofa domesticus) manure. All fertilizers were applied at an application rate of 217.6 kg N/ha. Simulated rainfall was applied at 50 mm/h for an average duration of 0.8 h. Runoff samples were collected, composited, and analyzed for nitrate N (NO3-N), ammonia N (NH3-N), total Kjeldahl N (TKN), ortho-P (PO4-P), total P (TP), chemical oxygen demand (COD), total suspended solids (TSS), fecal coliforms (FC), and fecal streptococci (FS). Application of the fertilizers did not alter the hydrologic characteristics of the receiving plots relative to the control plots. Concentrations of fertilizer constituents were almost always greater from treated than from control plots and were usually much greater. Flow-weighted mean concentrations of NH3-N, PO4-P, and TP were highest for the inorganic fertilizer treatment (42.0, 26.6, and 27.9 mg/L, respectively). Runoff COD and TSS concentrations were greatest for the poultry litter treatment. Concentrations of FC and FS were greater for fertilized than for control plots with no differences among fertilized plots, but FC concentrations for all treatments were in excess of Arkansas' primary and secondary contact standards. Mass losses of fertilizer constituents were low (≤ 3 kg/ha) and were small proportions (≤ 3 percent) of amounts applied.  相似文献   

19.
The microbiological and physico-chemical characteristics of the drinking water supplied by the Central Borehole at the University of Benin, Ugbowo Campus were investigated. The investigation entailed assessment of the pH, turbidity, total suspended solids, total dissolved solids, dissolved oxygen, temperature, salinity, conductivity, nitrate, nitrite, phosphate, sulphate, chloride, N-nitroso compounds, cadmium, chromium, nickel, lead, zinc, manganese, iron, coliform count, BOD5 and COD of the water at the Central Borehole and at ten residential quarters. The assessment indicated that the water was fit for drinking and other domestic applications. Results were also compared with WHO, EU and Nigeria FEPA standards. The results showed that the pH values of the water (5.01–5.86) and total coliform count (1–2/100 ml) expressed as MPN were outside the limits set by the WHO, EU and FEPA. The data also showed that the other water quality parameters assessed were within WHO, EU and FEPA permissible limits. The results of ANOVA showed that significant changes occurred during distribution.  相似文献   

20.
Fenton treatment (Fe2+/H2O2) and different ozone-based Advanced Oxidation Processes (AOPs) (O3, O3/OH and O3/H2O2) were evaluated as pre-treatment of a mature landfill leachate, in order to improve the biodegradability of its recalcitrant organic matter for subsequent biological treatment. With a two-fold diluted leachate, at optimised experimental conditions (initial pH 3, H2O2 to Fe2+ molar ratio of 3, Fe2+ dosage of 4 mmol L−1, and reaction time of 40 min) Fenton treatment removed about 46% of chemical oxygen demand (COD) and increased the five-day biochemical oxygen demand (BOD5) to COD ratio (BOD5/COD) from 0.01 to 0.15. The highest removal efficiency and biodegradability was achieved by ozone at higher pH values, solely or combined with H2O2. These results confirm the enhanced production of hydroxyl radical under such conditions. After the application for 60 min of ozone at 5.6 g O3 h−1, initial pH 7, and 400 mg L−1 of hydrogen peroxide, COD removal efficiency was 72% and BOD5/COD increased from 0.01 to 0.24. An estimation of the operating costs of the AOPs processes investigated revealed that Fe2+/H2O2 was the most economical system (8.2 € m−3 g−1 of COD removed) to treat the landfill leachate. This economic study, however, should be treated with caution since it does not consider the initial investment, prices at plant scale, maintenance and labour costs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号