首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
• A stable and electroconductive CNTs/ceramic membrane was fabricated. • The membrane with the electro-assistance exhibited optimal fouling mitigation. • The removal efficiency was improved by the -2.0 V electro-assistance. • Electro-assisted filtration is energy-saving than that of commercial membrane. Ultrafiltration is employed as an important process for water treatment and reuse, which is of great significance to alleviate the shortage of water resources. However, it suffers from severe membrane fouling and the trade-off between selectivity and permeability. In this work, a CNTs/ceramic flat sheet ultrafiltration membrane coupled with electro-assistance was developed for improving the antifouling and separation performance. The CNTs/ceramic flat sheet membrane was fabricated by coating cross-linked CNTs on ceramic membrane, featuring a good electroconductivity of 764.75 S/m. In the filtration of natural water, the permeate flux of the membrane with the cell voltage of -2.0 V was 1.8 times higher than that of the membrane without electro-assistance and 5.7-fold greater than that of the PVDF commercial membrane. Benefiting from the electro-assistance, the removal efficiency of the typical antibiotics was improved by 50%. Furthermore, the electro-assisted membrane filtration process showed 70% reduction in energy consumption compared with the filtration process of the commercial membrane. This work offers a feasible approach for membrane fouling mitigation and effluent quality improvement and suggests that the electro-assisted CNTs/ceramic membrane filtration process has great potential in the application of water treatment.  相似文献   

2.
• A fine fibre (40–60 nm diameter) interlayer (~1 µm thickness) was electrospun. • Fine fibre interlayer promoted formation of defect-free dense polyamide layer. • FO membrane with dual-layer substrate had less organic fouling potential. • High reverse salt flux accelerated organic fouling on FO membrane. Nanofibre-supported forward osmosis (FO) membranes have gained popularity owing to their low structural parameters and high water flux. However, the nanofibrous membranes are less stable in long-term use, and their fouling behaviours with foulants in both feed solution (FS) and draw solution (DS) is less studied. This study developed a nanofibrous thin-film composite (TFC) FO membrane by designing a tiered dual-layer nanofibrous substrate to enhance membrane stability during long-term usage and cleaning. Various characterisation methods were used to study the effect of the electrospun nanofibre interlayer and drying time, which is the interval after removing the M-phenylenediamine (MPD) solution and before reacting with trimesoyl chloride (TMC) solution, on the intrinsic separation FO performance. The separation performance of the dual-layer nanofibrous FO membranes was examined using model foulants (sodium alginate and bovine serum albumin) in both the FS and DS. The dual-layer nanofibrous substrate was superior to the single-layer nanofibrous substrate and showed a flux of 30.2 L/m2/h (LMH) when using 1.5 mol/L NaCl against deionised (DI) water in the active layer facing draw solution (AL-DS) mode. In the fouling test, the water flux was effectively improved without sacrificing the water/solute selectivity under the condition that foulants existed in both the FS and DS. In addition, the dual-layer nanofibrous TFC FO membrane was more robust during the fouling test and cleaning.  相似文献   

3.
• 1,4-Dioxane was degraded via the photo-Fenton reactive membrane filtration. • Degradation efficiency and AQY were both enhanced in photocatalytic membrane. • There is a tradeoff between photocatalytic degradation and membrane permeation flux. • Degradation pathways of 1,4-Dioxane is revealed by DFT analysis. The present study evaluated a photo-Fenton reactive membrane that achieved enhanced 1,4-Dioxane removal performance. As a common organic solvent and stabilizer, 1,4-Dioxane is widely used in a variety of industrial products and poses negative environmental and health impacts. The membrane was prepared by covalently coating photocatalyst of goethite (α-FeOOH) on a ceramic porous membrane as we reported previously. The effects of UV irradiation, H2O2 and catalyst on the removal efficiency of 1,4-Dioxane in batch reactors were first evaluated for optimized reaction conditions, followed by a systematical investigation of 1,4-Dioxane removal in the photo-Fenton membrane filtration mode. Under optimized conditions, the 1,4-Dioxane removal rate reached up to 16% with combination of 2 mmol/L H2O2 and UV365 irradiation (2000 µW/cm2) when the feed water was filtered by the photo-Fenton reactive membrane at a hydraulic retention time of 6 min. The removal efficiency and apparent quantum yield (AQY) were both enhanced in the filtration compared to the batch mode of the same photo-Fenton reaction. Moreover, the proposed degradation pathways were analyzed by density functional theory (DFT) calculations, which provided a new insight into the degradation mechanisms of 1,4-Dioxane in photo-Fenton reactions on the functionalized ceramic membrane.  相似文献   

4.
• The membrane bioreactor cost decreased by 38.2% by decreasing HRT from 72 h to 36 h. • Capital and operation costs contributed 62.1% and 37.9% to decreased costs. • The membrane bioreactor is 32.6% cheaper than the oxidation ditch for treatment. • The effluent COD also improved from 709.93±62.75 mg/L to 280±17.32 mg/L. • Further treatment also benefited from lower pretreatment investment. A cost sensitivity analysis was performed for an industrial membrane bioreactor to quantify the effects of hydraulic retention times and related operational parameters on cost. Different hydraulic retention times (72–24 h) were subjected to a flat-sheet membrane bioreactor updated from an existing 72 h oxidation ditch treating antibiotic production wastewater. Field experimental data from the membrane bioreactor, both full-scale (500 m3/d) and pilot (1.0 m3/d), were used to calculate the net present value (NPV), incorporating both capital expenditure (CAPEX) and operating expenditure. The results showed that the tank cost was estimated above membrane cost in the membrane bioreactor. The decreased hydraulic retention time from 72 to 36 h reduced the NPV by 38.2%, where capital expenditure contributed 24.2% more than operational expenditure. Tank construction cost was decisive in determining the net present value contributed 62.1% to the capital expenditure. The membrane bioreactor has the advantage of a longer lifespan flat-sheet membrane, while flux decline was tolerable. The antibiotics decreased to 1.87±0.33 mg/L in the MBR effluent. The upgrade to the membrane bioreactor also benefited further treatments by 10.1%–44.7% lower direct investment.  相似文献   

5.
• A pilot study was conducted for drinking water treatment using loose NF membranes. • The membranes had very high rejection of NOM and medium rejection of Ca2+/Mg2+. • Organic fouling was dominant and contribution of inorganic fouling was substantial. • Both organic and inorganic fouling had spatial non-uniformity on membrane surface. • Applying EDTA at basic conditions was effective in removing membrane fouling. Nanofiltration (NF) using loose membranes has a high application potential for advanced treatment of drinking water by selectively removing contaminants from the water, while membrane fouling remains one of the biggest problems of the process. This paper reported a seven-month pilot study of using a loose NF membrane to treat a sand filtration effluent which had a relatively high turbidity (~0.4 NTU) and high concentrations of organic matter (up to 5 mg/L as TOC), hardness and sulfate. Results showed that the membrane demonstrated a high rejection of TOC (by>90%) and a moderately high rejection of two pesticides (54%–82%) while a moderate rejection of both calcium and magnesium (~45%) and a low rejection of total dissolved solids (~27%). The membrane elements suffered from severe membrane fouling, with the membrane permeance decreased by 70% after 85 days operation. The membrane fouling was dominated by organic fouling, while biological fouling was moderate. Inorganic fouling was mainly caused by deposition of aluminum-bearing substances. Though inorganic foulants were minor contents on membrane, their contribution to overall membrane fouling was substantial. Membrane fouling was not uniform on membrane. While contents of organic and inorganic foulants were the highest at the inlet and outlet region, respectively, the severity of membrane fouling increased from the inlet to the outlet region of membrane element with a difference higher than 30%. While alkaline cleaning was not effective in removing the membrane foulants, the use of ethylenediamine tetraacetate (EDTA) at alkaline conditions could effectively restore the membrane permeance.  相似文献   

6.
• Bacteria could easily and quickly attached onto TEP to form protobiofilms. • TEP-protobiofilm facilitate the transport of bacteria to membrane surface. • More significant flux decline was observed in the presence of TEP-protobiofilms. • Membrane fouling shows higher sensitivity to protobiofilm not to bacteria level. Transparent exopolymer particles (TEPs) are a class of transparent gel-like polysaccharides, which have been widely detected in almost every kind of feed water to membrane systems, including freshwater, seawater and wastewater. Although TEP have been thought to be related to the membrane fouling, little information is currently available for their influential mechanisms and the pertinence to biofouling development. The present study, thus, aims to explore the impact of TEPs on biofouling development during ultrafiltration. TEP samples were inoculated with bacteria for several hours before filtration and the formation of “protobiofilm” (pre-colonized TEP by bacteria) was examined and its influence on biofouling was determined. It was observed that the bacteria can easily and quickly attach onto TEPs and form protobiofilms. Ultrafiltration experiments further revealed that TEP-protobiofilms served as carriers which facilitated and accelerated transport of bacteria to membrane surface, leading to rapid development of biofouling on the ultrafiltration membrane surfaces. Moreover, compared to the feed water containing independent bacteria and TEPs, more flux decline was observed with TEP-protobiofilms. Consequently, it appeared from this study that TEP-protobiofilms play a vital role in the development of membrane biofouling, but unfortunately, this phenomenon has been often overlooked in the literature. Obviously, these findings in turn may also challenge the current understanding of organic fouling and biofouling as membrane fouling caused by TEP-protobiofilm is a combination of both. It is expected that this study might promote further research in general membrane fouling mechanisms and the development of an effective mitigation strategy.  相似文献   

7.
• Effects of metabolic uncouplers addition on sludge reduction were carried out. • TCS addition effectively inhibited ATP synthesis and reduced sludge yield. • The effluent quality such as TOC and ammonia deteriorated but not significantly. • Suitable dosage retarded biofouling during sludge water recovery by UF membrane. Energy uncoupling is often used for sludge reduction because it is easy to operate and does not require a significant amount of extra equipments (i.e. no additional tank required). However, over time the supernatant extracted using this method can deteriorate, ultimately requiring further treatment. The purpose of this study was to determine the effect of using a low-pressure ultrafiltration membrane process for sludge water recovery after the sludge had undergone an energy uncoupling treatment (using 3,3′,4′,5-tetrachlorosalicylanilide (TCS)). Energy uncoupling was found to break apart sludge floc by reducing extracellular polymeric substances (EPS) and adenosine triphosphate (ATP) content. Analysis of supernatant indicated that when energy uncoupling and membrane filtration were co-applied and the TCS dosage was below 30 mg/L, there was no significant deterioration in organic component removal. However, ammonia and phosphate concentrations were found to increase as the concentration of TCS added increased. Additionally, due to low sludge concentrations and EPS contents, addition of 30–60 mg/L TCS during sludge reduction increased the permeate flux (two times higher than the control) and decreased the hydraulic reversible and cake layer resistances. In contrast, high dosage of TCS aggravated membrane fouling by forming compact fouling layers. In general, this study found that the co-application of energy uncoupling and membrane filtration processes represents an effective alternative method for simultaneous sludge reduction and sludge supernatant recovery.  相似文献   

8.
•PSBF performed better than PAC and PAM in CODCr removals. •PSBF was more insensitive to changing pH than PAC and PAM. •PAC could remove humic acid-like pollutants and dye particles. •PSBF was efficient in removing tryptophan-like pollutants from PPDW. •A secondary coagulation-flocculation process (PAC→PSBF) is proposed here. In our previous studies, several papermaking sludge-based flocculants (PSBFs) were synthesized from wood pulp papermaking sludge. The structure-activity relationships of the PSBFs have been investigated in simulated dye wastewater treatment, but their efficiencies in practical printing and dyeing wastewater (PPDW) treatment are unknown. Herein, an PSBF was prepared, and its performance is discussed in comparison to polyaluminium chloride (PAC) and polyacrylamide (PAM) in PPDW treatment. The PSBF was used in three ways: as an independent flocculant, as a PAC aid, or used to treat the effluent of the PAC system. The results indicated that adding PSBF alone produced similar color and chemical oxygen demand (CODCr) removals as the PAC system alone, but PSBF performed better than PAC when the pH of PPDW was higher than 7.0. Adding PSBF as a PAC aid improved the color, CODCr and turbidity removals, but the elimination efficiencies were slightly lower than those of the PAC+ PAM system. However, when PSBF was used as a flocculant to treat the effluent of the PAC system (PAC→PSBF), the effluent qualities were enhanced. Compared with the PAC system, the color and CODCr removals of PAC→PSBF system increased by 16.21% and 13.26%, respectively. The excitation and emission matrix fluorescence results indicated that PSBF removed tryptophan-like pollutants more efficiently than PAC. Considering the pH requirements of the subsequent bioreactor treatment in practice, the PAC→PSBF system were also investigated at the PPDW pH level of 7.0. Its maximum removal efficiencies of color, CODCr and turbidity were 90.17%, 32.60% and 82.50%, respectively.  相似文献   

9.
• CWF is a sustainable POU water treatment method for developing areas. • CWF manufacturing process is critical for its filtration performance. • Simultaneous increase of flow rate and pathogen removal is a challenge. • Control of pore size distribution holds promises to improve CWF efficiency. • Novel coatings of CWFs are a promising method to improve contaminant removal. Drinking water source contamination poses a great threat to human health in developing countries. Point-of-use (POU) water treatment techniques, which improve drinking water quality at the household level, offer an affordable and convenient way to obtain safe drinking water and thus can reduce the outbreaks of waterborne diseases. Ceramic water filters (CWFs), fabricated from locally sourced materials and manufactured by local labor, are one of the most socially acceptable POU water treatment technologies because of their effectiveness, low-cost and ease of use. This review concisely summarizes the critical factors that influence the performance of CWFs, including (1) CWF manufacturing process (raw material selection, firing process, silver impregnation), and (2) source water quality. Then, an in-depth discussion is presented with emphasis on key research efforts to address two major challenges of conventional CWFs, including (1) simultaneous increase of filter flow rate and bacterial removal efficiency, and (2) removal of various concerning pollutants, such as viruses and metal(loid)s. To promote the application of CWFs, future research directions can focus on: (1) investigation of pore size distribution and pore structure to achieve higher flow rates and effective pathogen removal by elucidating pathogen transport in porous ceramic and adjusting manufacture parameters; and (2) exploration of new surface modification approaches with enhanced interaction between a variety of contaminants and ceramic surfaces.  相似文献   

10.
• Underwater superoleophobic membrane was fabricated by deposition of catechol/chitosan. • The membrane had ultrahigh pure water flux and was stable under harsh pH conditions. • The membrane exhibited remarkable antifouling property in O/W emulsion separation. • The hydration layer on the membrane surface prevented oil droplets adhesion. Low-pressure membrane filtrations are considered as effective technologies for sustainable oil/water separation. However, conventional membranes usually suffer from severe pore clogging and surface fouling, and thus, novel membranes with superior wettability and antifouling features are urgently required. Herein, we report a facile green approach for the development of an underwater superoleophobic microfiltration membrane via one-step oxidant-induced ultrafast co-deposition of naturally available catechol/chitosan on a porous polyvinylidene fluoride (PVDF) substrate. Membrane morphology and surface chemistry were studied using a series of characterization techniques. The as-prepared membrane retained the original pore structure due to the ultrathin and uniform catechol/chitosan coating. It exhibited ultrahigh pure water permeability and robust chemical stability under harsh pH conditions. Moreover, the catechol/chitosan hydrophilic coating on the membrane surface acting as an energetic barrier for oil droplets could minimize oil adhesion on the surface, which endowed the membrane with remarkable antifouling property and reusability in a cyclic oil-in-water (O/W) emulsion separation. The modified membrane exhibited a competitive flux of ~428 L/(m2·h·bar) after three filtration cycles, which was 70% higher than that of the pristine PVDF membrane. These results suggest that the novel underwater superoleophobic membrane can potentially be used for sustainable O/W emulsions separation, and the proposed green facile modification approach can also be applied to other water-remediation materials considering its low cost and simplicity.  相似文献   

11.
• Nanoparticle incorporation and anti-biofouling grafting were integrated. • Flux of modified membranes was enhanced without rejection sacrificing. • Anti-biofouling property of modified membranes was improved. High performance is essential for the polyamide (PA) reverse osmosis (RO) membranes during the desalination process. Herein, RO membranes with high permselectivity and anti-biofouling properties were fabricated by nanoparticles incorporation and anti-biofouling grafting. Hydrotalcite (HT) incorporation was performed with a dual role, enhancing water flux and acting as grafting sites. The HT incorporation increased the water flux without sacrificing the salt rejection, compensating for the loss caused by the following grafting reaction. The exposed surface of HT acted as grafting sites for anti-biofouling agent dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride (DMOTPAC). The combination of HT incorporation and DMOTPAC grafting endowed RO membranes with high permselectivity and anti-biofouling properties. The water flux of the modified membrane PA-HT-0.06 was 49.8 L/m2·h, which was 16.4% higher than that of the pristine membrane. The salt rejection of PA-HT-0.06 was 99.1%, which was comparable to that of the pristine membrane. As to the fouling of negatively charged lysozyme, the modified membrane’s water flux recovery was superior to that of the pristine membrane (e.g. 86.8% of PA-HT-0.06 compared to 78.2% of PA-pristine). The sterilization rates of PA-HT-0.06 for E. coli and B. subtilis were 97.3% and 98.7%, much higher than those of the pristine membrane (24.0% for E. coli and 26.7% for B. subtilis).  相似文献   

12.
• A high-performance electrode was prepared with super-aligned carbon nanotubes. • SACNT/AC electrode achieved a ~100% increase in desalination capacity and rate. • SACNT/AC electrode achieved a ~26% increase in charge efficiency. • CUF process with SACNT/AC achieved an up to 2.43-fold fouling reduction. • SACNT/AC imparts overall improved water purification efficiency. The practical application of the capacitive deionization (CDI) enhanced ultrafiltration (CUF) technology is hampered due to low performance of electrodes. The current study demonstrated a novel super-aligned carbon nanotube (SACNT)/activated carbon (AC) composite electrode, which was prepared through coating AC on a cross-stacked SACNT film. The desalination capability and water purification performance of the prepared electrode were systematically investigated at different applied voltages (0.8–1.2 V) with a CDI system and a CUF system, respectively. In the CDI tests, as compared with the control AC electrode, the SACNT/AC electrode achieved an approximately 100% increase in both maximum salt adsorption capacity and average salt adsorption rate under all the applied voltage conditions, demonstrating a superior desalination capability. Meanwhile, a conspicuous increase by an average of ~26% in charge efficiency was also achieved at all the voltages. In the CUF tests, as compared with the control run at 0 V, the treatment runs at 0.8, 1.0, and 1.2 V achieved a 2.40-fold, 2.08-fold, and 2.43-fold reduction in membrane fouling (calculated according to the final transmembrane pressure (TMP) data at the end of every purification stage), respectively. The average TMP increasing rates at 0.8, 1.0, and 1.2 V were also roughly two times smaller than that at 0 V, indicating a dramatical reduction of membrane fouling. The SACNT/AC electrode also maintained its superior desalination capability in the CUF process, resulting in an overall improved water purification efficiency.  相似文献   

13.
• Principles and methods for fluorescence EEM are systematically outlined. • Fluorophore peak/region/component and energy information can be extracted from EEM. • EEM can fingerprint the physical/chemical/biological properties of DOM in MBRs. • EEM is useful for tracking pollutant transformation and membrane retention/fouling. • Improvements are still needed to overcome limitations for further studies. The membrane bioreactor (MBR) technology is a rising star for wastewater treatment. The pollutant elimination and membrane fouling performances of MBRs are essentially related to the dissolved organic matter (DOM) in the system. Three-dimensional excitation-emission matrix (3D-EEM) fluorescence spectroscopy, a powerful tool for the rapid and sensitive characterization of DOM, has been extensively applied in MBR studies; however, only a limited portion of the EEM fingerprinting information was utilized. This paper revisits the principles and methods of fluorescence EEM, and reviews the recent progress in applying EEM to characterize DOM in MBR studies. We systematically introduced the information extracted from EEM by considering the fluorescence peak location/intensity, wavelength regional distribution, and spectral deconvolution (giving fluorescent component loadings/scores), and discussed how to use the information to interpret the chemical compositions, physiochemical properties, biological activities, membrane retention/fouling behaviors, and migration/transformation fates of DOM in MBR systems. In addition to conventional EEM indicators, novel fluorescent parameters are summarized for potential use, including quantum yield, Stokes shift, excited energy state, and fluorescence lifetime. The current limitations of EEM-based DOM characterization are also discussed, with possible measures proposed to improve applications in MBR monitoring.  相似文献   

14.
• Cellulose-based membrane separates oily wastewater mimicking the living things. • The three central surface mechanisms were reviewed. • Preparation, performance, and mechanism are critically evaluated. • First review of wettability based cellulose membrane as major material. • The current and future importance of the research are discussed. It is challenging to purify oily wastewater, which affects water-energy-food production. One promising method is membrane-based separation. This paper reviews the current research trend of applying cellulose as a membrane material that mimics one of three typical biostructures: superhydrophobic, underwater superoleophobic, and Janus surfaces. Nature has provided efficient and effective structures through the evolutionary process. This has inspired many researchers to create technologies that mimic nature’s structures or the fabrication process. Lotus leaves, fish scales, and Namib beetles are three representative structures with distinct functional and surface properties: superhydrophobic, underwater superoleophobic, and Janus surfaces. The characteristics of these structures have been widely studied and applied to membrane materials to improve their performance. One attractive membrane material is cellulose, which has been studied from the perspective of its biodegradability and sustainability. In this review, the principles, mechanisms, fabrication processes, and membrane performances are summarized and compared. The theory of wettability is also described to build a comprehensive understanding of the concept. Finally, future outlook is discussed to challenge the gap between laboratory and industrial applications.  相似文献   

15.
• Fate of microplastics in integrated membrane system for water reuse was investigated. • Integrated membrane system has high removal efficiency (>98%) for microplastics. • Microplastics (>93%) were mainly removed through membrane bioreactor treatment. • Small scale fiber plastics (<200 μm) could break through reverse osmosis (RO) system. • The flux of microplastics maintained at 2.7 × 1011 MPs/d after the RO treatment. Rare information on the fate of microplastics in the integrated membrane system (IMS) system in full-scale wastewater treatment plant was available. The fate of microplastics in IMS in a coastal reclaimed water plant was investigated. The removal rate of microplastics in the IMS system reached 93.2% after membrane bioreactor (MBR) treatment while that further increased to 98.0% after the reverse osmosis (RO) membrane process. The flux of microplastics in MBR effluent was reduced from 1.5 × 1013 MPs/d to 10.2 × 1011 MPs/d while that of the RO treatment decreased to 2.7 × 1011 MPs/d. Small scale fiber plastics (<200 μm) could break through RO system according to the size distribution analysis. The application of the IMS system in the reclaimed water plant could prevent most of the microplastics from being discharged in the coastal water. These findings suggested that the IMS system was more efficient than conventional activated sludge system (CAS) for the removal of microplastics, while the discharge of small scale fiber plastics through the IMS system should also not be neglected because small scale fiber plastics (<200 μm) could break through IMS system equipped with the RO system.  相似文献   

16.
• We created a combined system for treating oilfield polymer-flooding wastewater. • The system was composed of coagulation, hydrolysis acidification and DMBR. • Coagulant integrated with demulsifier dominated the removal of crude oil. • The DMBR proceed efficiently without serious membrane fouling. A combined system composed of coagulation, hydrolysis acidification and dynamic membrane bioreactor (DMBR) was developed for treating the wastewater produced from polymer flooding. Performance and mechanism of the combined system as well as its respective units were also evaluated. The combined system has shown high-capacity to remove all contaminants in the influent. In this work, the coagulant, polyacrylamide-dimethyldiallyammonium chloride-butylacrylate terpolymer (P(DMDAAC-AM-BA)), integrated with demulsifier (SD-46) could remove 91.8% of crude oil and 70.8% of COD. Hydrolysis acidification unit improved the biodegradability of the influent and the experimental results showed that the highest acidification efficiency in hydrolysis acidification reactor was 20.36% under hydraulic retention time of 7 h. The DMBR proceeded efficiently without serious blockage process of membrane fouling, and the concentration of ammonia nitrogen (NH3-N), oil, chemical oxygen demand and biological oxygen demand in effluent were determined to be 3.4±2.1, 0.3±0.6, 89.7±21.3 and 13±4.7 mg/L.  相似文献   

17.
• Electrode fouling is characterized by non-destructive characterization. • Electrode fouling is highly dependent on electrochemical process. • Active chlorine can prevent the formation of polymeric fouling film. Electrode fouling is a problem that commonly occurs during electro-oxidation water purification. This study focused on identifying the fouling behavior of Pt electrode associated with the formation of polymeric layer during electro-oxidation of phenol. The in situ electrochemical measurements and non-destructive observation of the electrode morphology were reported. The results demonstrated that the electrode fouling was highly dependent on thermodynamic process of electrode that was controlled by anode potential. At anode potential lower than 1.0 V vs SHE, the direct electro-oxidation caused the electrode fouling by the formation of polymeric film. The fouling layer decreased the electrochemically active surface area from 8.38 cm2 to 1.57 cm2, indicated by the formation of polymeric film with thickness of 2.3 mm, increase in mass growing at a rate of 3.26 μg/cm2/min. The degree to which the anode was fouled was independent of anion in the electrolyte. In comparison, at anode potential higher than 2.7 V vs SHE, the anions (e.g., chloride) could exert a major influence to the behavior of electrode fouling. The presence of chloride was shown to mitigate the fouling of electrode significantly through preventing the formation of polymeric film by active chlorine (e.g., Cl• and Cl2) produced from anodic oxidation of chloride. Since chloride is the most abundant anionic species existing in both natural and engineered water system, this study not only offers a deep insight into the mechanism of electrode fouling, but also suggests strategies for anti-fouling in the presence of chloride in electro-oxidation process.  相似文献   

18.
• Mesoporous silica nanoparticle was modified with 4-triethoxysilylaniline. • AMSN-based TFN-RO membranes were prepared for seawater desalination. • Water transport capability of the AMSN was limited by polyamide. • Polyamide still plays a key role in permeability of the TFN RO membranes. Mesoporous silica nanoparticles (MSN), with higher water permeability than NaA zeolite, were used to fabricate thin-film nanocomposite (TFN) reverse osmosis (RO) membranes. However, only aminoalkyl-modified MSN and low-pressure (less than 2.1 MPa) RO membrane were investigated. In this study, aminophenyl-modified MSN (AMSN) were synthesized and used to fabricate high-pressure (5.52 MPa) RO membranes. With the increasing of AMSN dosage, the crosslinking degree of the aromatic polyamide decreased, while the hydrophilicity of the membranes increased. The membrane morphology was maintained to show a ridge-and-valley structure, with only a slight increase in membrane surface roughness. At the optimum conditions (AMSN dosage of 0.25 g/L), when compared with the pure polyamide RO membrane, the water flux of the TFN RO membrane (55.67 L/m2/h) was increased by about 21.6%, while NaCl rejection (98.97%) was slightly decreased by only 0.29%. However, the water flux of the membranes was much lower than expected. We considered that the enhancement of RO membrane permeability is attributed to the reduction of the effective thickness of the PA layer.  相似文献   

19.
• MES was constructed for simultaneous ammonia removal and acetate production. • Energy consumption was different for total nitrogen and ammonia nitrogen removal. • Energy consumption for acetate production was about 0.04 kWh/g. • Nitrate accumulation explained the difference of energy consumption. • Transport of ammonia and acetate across the membrane deteriorated the performance. Microbial electrosynthesis (MES) is an emerging technology for producing chemicals, and coupling MES to anodic waste oxidation can simultaneously increase the competitiveness and allow additional functions to be explored. In this study, MES was used for the simultaneous removal of ammonia from synthetic urine and production of acetate from CO2. Using graphite anode, 83.2%±5.3% ammonia removal and 28.4%±9.9% total nitrogen removal was achieved, with an energy consumption of 1.32 kWh/g N for total nitrogen removal, 0.45 kWh/g N for ammonia nitrogen removal, and 0.044 kWh/g for acetate production. Using boron-doped diamond (BDD) anode, 70.9%±12.1% ammonia removal and 51.5%±11.8% total nitrogen removal was obtained, with an energy consumption of 0.84 kWh/g N for total nitrogen removal, 0.61 kWh/g N for ammonia nitrogen removal, and 0.043 kWh/g for acetate production. A difference in nitrate accumulation explained the difference of total nitrogen removal efficiencies. Transport of ammonia and acetate across the membrane deteriorated the performance of MES. These results are important for the development of novel electricity-driven technologies for chemical production and pollution removal.  相似文献   

20.
• Mechanism of DCM disproportionation over mesoporous TiO2 was studied. • DCM was completely eliminated at 350℃ under 1 vol.% humidity. • Anatase (001) was the key for disproportionation. • A competitive oxidation route co-existed with disproportionation. • Disproportionation was favored at low temperature. Mesoporous TiO2 was synthesized via nonhydrolytic template-mediated sol-gel route. Catalytic degradation performance upon dichloromethane over as-prepared mesoporous TiO2, pure anatase and rutile were investigated respectively. Disproportionation took place over as-made mesoporous TiO2 and pure anatase under the presence of water. The mechanism of disproportionation was studied by in situ FTIR. The interaction between chloromethoxy species and bridge coordinated methylenes was the key step of disproportionation. Formate species and methoxy groups would be formed and further turned into carbon monoxide and methyl chloride. Anatase (001) played an important role for disproportionation in that water could be dissociated into surface hydroxyl groups on such structure. As a result, the consumed hydroxyl groups would be replenished. In addition, there was another competitive oxidation route governed by free hydroxyl radicals. In this route, chloromethoxy groups would be oxidized into formate species by hydroxyl radicals transfering from the surface of TiO2. The latter route would be more favorable at higher temperature.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号