首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
• Genotoxicity of substances is unknown in the water after treatment processes. • Genotoxicity decreased by activated carbon treatment but increased by chlorination. • Halogenated hydrocarbons and aromatic compounds contribute to genotoxicity. • Genotoxicity was assessed by umu test; acute and chronic toxicity by ECOSAR. • Inconsistent results confirmed that genotoxicity cannot be assessed by ECOSAR. Advanced water treatment is commonly used to remove micropollutants such as pesticides, endocrine disrupting chemicals, and disinfection byproducts in modern drinking water treatment plants. However, little attention has been paid to the changes in the genotoxicity of substances remaining in the water following the different water treatment processes. In this study, samples were collected from three drinking water treatment plants with different treatment processes. The treated water from each process was analyzed and compared for genotoxicity and the formation of organic compounds. The genotoxicity was evaluated by an umu test, and the acute and chronic toxicity was analyzed through Ecological Structure- Activity Relationship (ECOSAR). The results of the umu test indicated that biological activated carbon reduced the genotoxicity by 38%, 77%, and 46% in the three drinking water treatment plants, respectively, while chlorination increased the genotoxicity. Gas chromatograph-mass spectrometry analysis revealed that halogenated hydrocarbons and aromatic compounds were major contributors to genotoxicity. The results of ECOSAR were not consistent with those of the umu test. Therefore, we conclude that genotoxicity cannot be determined using ECOSAR .  相似文献   

2.
• Seasonal and treatment-process variations in invertebrates in a DWTP were analyzed. • The propagation and leakage of invertebrates in BAC filter were the most serious. • Invertebrates can survive and reproduce in chlorine disinfected clear water tanks. • Proportions of endogenous invertebrates increased along the treatment process. Problems associated with excessive propagation and leakage of invertebrates in drinking water have received increasing attention in recent years. We performed a monthly survey of invertebrate abundance and taxa in the effluent of each treatment stage in a drinking water treatment plant between May 2015 and April 2016 and analyzed seasonal and treatment-process variations in invertebrates. The results showed that invertebrate abundances in raw water, effluent of the biological activated carbon (BAC) filter, and finished water significantly correlated with water temperature, whereas no correlation was observed between water temperature and invertebrate abundance in the effluents of the sedimentation tank and sand filter. The dominant taxa in the effluent of each treatment stage were rotifers, nematodes, and crustaceans. The sedimentation tank could efficiently remove invertebrates with an annual average removal rate of 92%. The propagation and leakage of invertebrates occurred in the sand and BAC filters but more seriously in the latter. The average reproduction rate in the BAC filter was 268.8% with rotifers as the taxon that leaked the most. Invertebrate survival and reproduction were also observed in the chlorine-disinfected clean water reservoir with an average reproduction rate of 41.9%. Owing to differences in chlorine resistance, the reproduction ability of the dominant taxa was in the order nematodes>crustaceans>rotifers. The proportion of endogenous invertebrates gradually increased along the treatment process. The average proportion of endogenous invertebrates in the finished water was higher than 79.0%. Our findings suggested that waterworks should pay more attention to endogenous invertebrate growth.  相似文献   

3.
• Published data was used to analyze the fate of ARGs in water treatment. • Biomass removal leads to the reduction in absolute abundance of ARGs. • Mechanism that filter biofilm maintain ARB/ARGs was summarized. • Potential BAR risks caused by biofiltration and chlorination were proposed. The bacterial antibiotic resistome (BAR) is one of the most serious contemporary medical challenges. The BAR problem in drinking water is receiving growing attention. In this study, we focused on the distribution, changes, and health risks of the BAR throughout the drinking water treatment system. We extracted the antibiotic resistance gene (ARG) data from recent publications and analyzed ARG profiles based on diversity, absolute abundance, and relative abundance. The absolute abundance of ARG was found to decrease with water treatment processes and was positively correlated with the abundance of 16S rRNA (r2 = 0.963, p<0.001), indicating that the reduction of ARG concentration was accompanied by decreasing biomass. Among treatment processes, biofiltration and chlorination were discovered to play important roles in shaping the bacterial antibiotic resistome. Chlorination exhibited positive effects in controlling the diversity of ARG, while biofiltration, especially granular activated carbon filtration, increased the diversity of ARG. Both biofiltration and chlorination altered the structure of the resistome by affecting relative ARG abundance. In addition, we analyzed the mechanism behind the impact of biofiltration and chlorination on the bacterial antibiotic resistome. By intercepting influent ARG-carrying bacteria, biofilters can enrich various ARGs and maintain ARGs in biofilm. Chlorination further selects bacteria co-resistant to chlorine and antibiotics. Finally, we proposed the BAR health risks caused by biofiltration and chlorination in water treatment. To reduce potential BAR risk in drinking water, membrane filtration technology and water boiling are recommended at the point of use.  相似文献   

4.
• Wide occurrence of Cr(VI) in US source drinking water. • A strong dependence of occurrence on groundwater sources. • Elucidate Redox and equilibrium chemistry of Cr(VI). • Sn(II)-based and TiO2-based reductive treatments hold extreme promise. • Key challenges include residual waste, Cr(VI) re-generation and socioeconomic drivers. Chromium (Cr) typically exists in either trivalent and hexavalent oxidation states in drinking water, i.e., Cr(III) and Cr(VI), with Cr(VI) of particular concern in recent years due to its high toxicity and new regulatory standards. This Account presented a critical analysis of the sources and occurrence of Cr(VI) in drinking water in the United States, analyzed the equilibrium chemistry of Cr(VI) species, summarized important redox reaction relevant to the fate of Cr(VI) in drinking water, and critically reviewed emerging Cr(VI) treatment technologies. There is a wide occurrence of Cr(VI) in US source drinking water, with a strong dependence on groundwater sources, mainly due to naturally weathering of chromium-containing aquifers. Challenges regarding traditional Cr(VI) treatment include chemical cost, generation of secondary waste and inadvertent re-generation of Cr(VI) after treatment. To overcome these challenges, reductive Cr(VI) treatment technologies based on the application of stannous tin or electron-releasing titanium dioxide photocatalyst hold extreme promise in the future. To moving forward in the right direction, three key questions need further exploration for the technology implementation, including effective management of residual waste, minimizing the risks of Cr(VI) re-occurrence downstream of drinking water treatment plant, and promote the socioeconomic drivers for Cr(VI) control in the future.  相似文献   

5.
• A stable and electroconductive CNTs/ceramic membrane was fabricated. • The membrane with the electro-assistance exhibited optimal fouling mitigation. • The removal efficiency was improved by the -2.0 V electro-assistance. • Electro-assisted filtration is energy-saving than that of commercial membrane. Ultrafiltration is employed as an important process for water treatment and reuse, which is of great significance to alleviate the shortage of water resources. However, it suffers from severe membrane fouling and the trade-off between selectivity and permeability. In this work, a CNTs/ceramic flat sheet ultrafiltration membrane coupled with electro-assistance was developed for improving the antifouling and separation performance. The CNTs/ceramic flat sheet membrane was fabricated by coating cross-linked CNTs on ceramic membrane, featuring a good electroconductivity of 764.75 S/m. In the filtration of natural water, the permeate flux of the membrane with the cell voltage of -2.0 V was 1.8 times higher than that of the membrane without electro-assistance and 5.7-fold greater than that of the PVDF commercial membrane. Benefiting from the electro-assistance, the removal efficiency of the typical antibiotics was improved by 50%. Furthermore, the electro-assisted membrane filtration process showed 70% reduction in energy consumption compared with the filtration process of the commercial membrane. This work offers a feasible approach for membrane fouling mitigation and effluent quality improvement and suggests that the electro-assisted CNTs/ceramic membrane filtration process has great potential in the application of water treatment.  相似文献   

6.
• A pilot study was conducted for drinking water treatment using loose NF membranes. • The membranes had very high rejection of NOM and medium rejection of Ca2+/Mg2+. • Organic fouling was dominant and contribution of inorganic fouling was substantial. • Both organic and inorganic fouling had spatial non-uniformity on membrane surface. • Applying EDTA at basic conditions was effective in removing membrane fouling. Nanofiltration (NF) using loose membranes has a high application potential for advanced treatment of drinking water by selectively removing contaminants from the water, while membrane fouling remains one of the biggest problems of the process. This paper reported a seven-month pilot study of using a loose NF membrane to treat a sand filtration effluent which had a relatively high turbidity (~0.4 NTU) and high concentrations of organic matter (up to 5 mg/L as TOC), hardness and sulfate. Results showed that the membrane demonstrated a high rejection of TOC (by>90%) and a moderately high rejection of two pesticides (54%–82%) while a moderate rejection of both calcium and magnesium (~45%) and a low rejection of total dissolved solids (~27%). The membrane elements suffered from severe membrane fouling, with the membrane permeance decreased by 70% after 85 days operation. The membrane fouling was dominated by organic fouling, while biological fouling was moderate. Inorganic fouling was mainly caused by deposition of aluminum-bearing substances. Though inorganic foulants were minor contents on membrane, their contribution to overall membrane fouling was substantial. Membrane fouling was not uniform on membrane. While contents of organic and inorganic foulants were the highest at the inlet and outlet region, respectively, the severity of membrane fouling increased from the inlet to the outlet region of membrane element with a difference higher than 30%. While alkaline cleaning was not effective in removing the membrane foulants, the use of ethylenediamine tetraacetate (EDTA) at alkaline conditions could effectively restore the membrane permeance.  相似文献   

7.
• Quantitative global ARGs profile in dialysis water was investigated. • Totally 35 ARGs were found in the dialysis treatment train. • 29 ARGs (highest) were found in carbon filtration effluent. erm and mtrD-02 occurred in the final effluent. • The effluent was associated with health risks even after RO treatment. Dialysis water is directly related to the safety of hemodialysis patients, thus its quality is generally ensured by a stepwise water purification cascade. To study the effect of water treatment on the presence of antibiotic resistance genes (ARGs) in dialysis water, this study used propidium monoazide (PMA) in conjunction with high throughput quantitative PCR to analyze the diversity and abundance of ARGs found in viable bacteria from water having undergone various water treatment processes. The results indicated the presence of 35 ARGs in the effluents from the different water treatment steps. Twenty-nine ARGs were found in viable bacteria from the effluent following carbon filtration, the highest among all of the treatment processes, and at 6.96 Log (copies/L) the absolute abundance of the cphA gene was the highest. Two resistance genes, erm (36) and mtrD-02, which belong to the resistance categories macrolides-lincosamides-streptogramin B (MLSB) and other/efflux pump, respectively, were detected in the effluent following reverse osmosis treatment. Both of these genes have demonstrated the potential for horizontal gene transfer. These results indicated that the treated effluent from reverse osmosis, the final treatment step in dialysis-water production, was associated with potential health risks.  相似文献   

8.
• An innovative bubble column tower BPE was designed to treat the black-odorous water. • PO43, S2 and turbidity were removed, and dissolved oxygen was enriched in the BPE. • An aluminum bipolar electrode gave the best oxygen enrichment and pollutant removal. • Changes of microorganisms confirmed the improvement in water quality achieved. The large amount of municipal wastewater discharged into urban rivers sometimes exceeds the rivers’ self-purification capacity leading to black-odorous polluted water. Electro-flocculation has emerged as a powerful remediation technology. Electro-flocculation in a bubble column tower with a bipolar electrode (BPE) was tested in an attempt to overcome the high resistance and weak gas-floatation observed with a monopolar electrode (MPE) in treating such water. The BPE reactor tested had a Ti/Ta2O5-IrO2 anode and a graphite cathode with an iron or aluminum bipolar electrode suspended between them. It was tested for its ability to reduce turbidity, phosphate and sulphion and to increase the concentration of dissolved oxygen. The inclusion of the bipolar electrode was found to distinctly improved the system’s conductivity. The system’s electro-flocculation and electrical floatation removed turbidity, phosphate and sulphion completely, and the dissolved oxygen level improved from 0.29 to 6.28 mg/L. An aluminum bipolar electrode performed better than an iron one. Changes in the structure of the microbial community confirmed a significant improvement in water quality.  相似文献   

9.
• 23 available research articles on MPs in drinking water treatment are reviewed. • The effects of treatment conditions and MP properties on MP removal are discussed. • DWTPs with more steps generally are more effective in removing MPs. • Smaller MPs (e.g.,<10 μm) are more challenging in drinking water treatment. Microplastics (MPs) have been widely detected in drinking water sources and tap water, raising the concern of the effectiveness of drinking water treatment plants (DWTPs) in protecting the public from exposure to MPs through drinking water. We collected and analyzed the available research articles up to August 2021 on MPs in drinking water treatment (DWT), including laboratory- and full-scale studies. This article summarizes the major MP compositions (materials, sizes, shapes, and concentrations) in drinking water sources, and critically reviews the removal efficiency and impacts of MPs in various drinking water treatment processes. The discussed drinking water treatment processes include coagulation-flocculation (CF), membrane filtration, sand filtration, and granular activated carbon (GAC) filtration. Current DWT processes that are purposed for particle removal are generally effective in reducing MPs in water. Various influential factors to MP removal are discussed, such as coagulant type and dose, MP material, shape and size, and water quality. It is anticipated that better MP removal can be achieved by optimizing the treatment conditions. Moreover, the article framed the major challenges and future research directions on MPs and nanoplastics (NPs) in DWT.  相似文献   

10.
• A model-free sewer-WWTP integrated control was proposed. • A dynamic discrete control based on the water level was developed. • The approach could improve the sewer operation against flow fluctuation. • The approach could increase transport capacity and enhance pump efficiency. This study aims to propose a multi-point integrated real-time control method based on discrete dynamic water level variations, which can be realized only based on the programmable logic controller (PLC) system without using a complex mathematical model. A discretized water level control model was developed to conduct the real-time control based on data-automation. It combines the upstream pumping stations and the downstream influent pumping systems of wastewater treatment plant (WWTP). The discretized water level control method can regulate dynamic wastewater pumping flow of pumps following the dynamic water level variation in the sewer system. This control method has been successfully applied in practical integrated operations of sewer-WWTP following the sensitive flow disturbances of the sewer system. The operational results showed that the control method could provide a more stabilized regulate pumping flow for treatment process; it can also reduce the occurrence risk of combined sewer overflow (CSO) during heavy rainfall events by increasing transport capacity of pumping station and influent flow in WWTP, which takes full advantage of storage space in the sewer system.  相似文献   

11.
• Swimming pool water was studied for DBPs upon exposure to additional stimulants. • DBP formation could be induced by residual chlorine and extended incubation. • Urine led to a massive formation of chloroform with additional stimulants. • Reactions between chlorine and anthropogenic organics were slow and long-lasting. • Urine control and air ventilation should be on the priority list for pool management. Anthropogenic organics are known to be responsible for the formation of harmful disinfection by-products (DBPs) in swimming pool water (SPW). The research explored an important scenario of SPW with no additional anthropogenic organic input. With stimulations by residual chlorine or additional chlorine and extended incubation, the formation of DBPs, especially chloroform, was significantly induced. Similar observations were found by investigating synthetic SPW made with sweat and urine. The presence of urine led to a massive formation of chloroform, as noted by an approximate 19-fold increase after 165-day incubation with a shock chlorine dose. The research suggests that consistent residual chlorine and long water retention as two typical features of SPW could unlock the DBP formation potential of anthropogenic organics. Thus, limiting the introduction of anthropogenic organics may not have an immediate effect on reducing DBP levels, because their reactions with chlorine can be slow and long-lasting. Pool management should prioritize on control of urine and improving air ventilation. This work is useful to deepen understandings about DBP formation in SPW and provide implications for pool management and prospective legislation.  相似文献   

12.
• Annual AOCs in MBR effluents were stable with small increase in warmer seasons. • Significant increase in AOC levels of tertiary effluents were observed. • Coagulation in prior to ozonation can reduce AOC formation in tertiary treatment. • ∆UV254 and SUVA can be surrogates to predict the AOC changes during ozonation. As water reuse development has increased, biological stability issues associated with reclaimed water have gained attention. This study evaluated assimilable organic carbon (AOC) in effluents from a full-scale membrane biological reactor (MBR) plant and found that they were generally stable over one year (125–216 µg/L), with slight increases in warmer seasons. After additional tertiary treatments, the largest increases in absolute and specific AOCs were detected during ozonation, followed by coagulation-ozonation and coagulation. Moreover, UV254 absorbance is known to be an effective surrogate to predict the AOC changes during ozonation. Applying coagulation prior to ozonation of MBR effluents for removal of large molecules was found to reduce the AOC formation compared with ozonation treatment alone. Finally, the results revealed that attention should be paid to seasonal variations in influent and organic fraction changes during treatment to enable sustainable water reuse.  相似文献   

13.
• Emerging titanium coagulation was high-efficient for algae-laden water treatment. • Polytitanium coagulation was capable for both algae and organic matter removal. • Surface water purification was improved by around 30% due to algae inclusion. • Algae functioned as flocculant aid to assist polytitanium coagulation. • Algae could enhance charge neutralization capability of polytitanium coagulant. Titanium-based coagulation has proved to be effective for algae-laden micro-polluted water purification processes. However, the influence of algae inclusion in surface water treatment by titanium coagulation is barely reported. This study reports the influence of both Microcystis aeruginosa and Microcystis wesenbergii in surface water during polytitanium coagulation. Jar tests were performed to evaluate coagulation performance using both algae-free (controlled) and algae-laden water samples, and floc properties were studied using a laser diffraction particle size analyzer for online monitoring. Results show that polytitanium coagulation can be highly effective in algae separation, removing up to 98% from surface water. Additionally, the presence of algae enhanced organic matter removal by up to 30% compared to controlled water containing only organic matter. Polytitanium coagulation achieved significant removal of fluorescent organic materials and organic matter with a wide range of molecular weight distribution (693–4945 Da) even in the presence of algae species in surface water. The presence of algae cells and/or algal organic matter is likely to function as an additional coagulant or flocculation aid, assisting polytitanium coagulation through adsorption and bridging effects. Although the dominant coagulation mechanisms with polytitanium coagulant were influenced by the coagulant dosage and initial solution pH, algae species in surface water could enhance the charge neutralization capability of the polytitanium coagulant. Algae-rich flocs were also more prone to breakage with strength factors approximately 10% lower than those of algae-free flocs. Loose structure of the flocs will require careful handling of the flocs during coagulation-sedimentation-filtration processes.  相似文献   

14.
• Functional groups of AM and EDTA in composite increased removal of Cr(VI) and CR. • Removal process reached equilibrium within 30 min and was minimally affected by pH. • Elimination of Cr(VI) was promoted by coexisting CR. • Adsorption process of CR was less influenced by the presence of Cr(VI). • Mechanisms were electrostatic attraction, surface complexation and anion exchange. We prepared ethylenediaminetetraacetic acid (EDTA)-intercalated MgAl-layered double hydroxide (LDH-EDTA), then grafted acrylamide (AM) to the LDH-EDTA by a cross-linking method to yield a LDH-EDTA-AM composite; we then evaluated its adsorptive ability for Congo red (CR) and hexavalent chromium (Cr(VI)) in single and binary adsorption systems. The adsorption process on LDH-EDTA-AM for CR and Cr(VI) achieved equilibrium quickly, and the removal efficiencies were minimally affected by initial pH. The maximum uptake quantities of CR and Cr(VI) on LDH-EDTA-AM were 632.9 and 48.47 mg/g, respectively. In mixed systems, chromate removal was stimulated by the presence of CR, while the adsorption efficiency of CR was almost not influenced by coexisting Cr(VI). The mechanisms involved electrostatic attraction, surface complexation, and anion exchange for the adsorption of both hazardous pollutants. In the Cr(VI) adsorption process, reduction also took place. The removal efficiencies in real contaminated water were all higher than those in the laboratory solutions.  相似文献   

15.
• Isotope dilution method was developed for the determination of 27 PPCPs in water. • The established method was successfully applied to different types of water samples. • The correction effect of corresponding 27 ILSs over 70 d was investigated. • Benefit of isotopic dilution method was illustrated for three examples. Pharmaceuticals and personal care products (PPCPs) are a unique group of emerging and non-persistent contaminants. In this study, 27 PPCPs in various water samples were extracted by solid phase extraction (SPE), and determined by isotope dilution method using liquid chromatography coupled to tandem triple quadruple mass spectrometer (LC-MS/MS). A total of 27 isotopically labeled standards (ILSs) were applied to correct the concentration of PPCPs in spiked ultrapure water, drinking water, river, effluent and influent sewage. The corrected recoveries were 73%–122% with the relative standard deviation (RSD)<16%, except for acetaminophen. The matrix effect for all kinds of water samples was<22% and the method quantitation limits (MQLs) were 0.45–8.6 ng/L. The developed method was successfully applied on environmental water samples. The SPE extracts of spiked ultrapure water, drinking water, river and wastewater effluent were stored for 70 days, and the ILSs-corrected recoveries of 27 PPCPs were obtained to evaluate the correction ability of ILSs in the presence of variety interferences. The recoveries of 27 PPCPs over 70 days were within the scope of 72%–140% with the recovery variation<37% in all cases. The isotope dilution method seems to be of benefit when the extract has to be stored for long time before the instrument analysis.  相似文献   

16.
• N-Cl-DCAM, an emerging N-DBP in drinking water was investigated. • A new BAC has a better removal efficiency for N-Cl-DCAM precursors than an old BAC. • N-Cl-DCAM precursors are more of low molecular weight and non-polar. • Adsorption of GAC plays a major role in removal of N-Cl-DCAM precursors by an O3-BAC. N-chloro-2,2-dichloroacetamide (N-Cl-DCAM) is an emerging nitrogenous disinfection by-product (N-DBP) which can occur in drinking water. In this study, an analytical method based on liquid chromatography with tandem mass spectrometry (LC-MS/MS) was developed to validate the concentration of N-Cl-DCAM, which was found to be 1.5 mg/L in the effluent of a waterworks receiving raw water from Taihu Lake, China. The changes of N-Cl-DCAM formation potential (N-Cl-DCAMFP) in the drinking water treatment process and the removal efficiency of its precursors in each unit were evaluated. Non-polar organics accounted for the majority of N-Cl-DCAM precursors, accounting for 70% of the N-Cl-DCAM FP. The effect of conventional water treatment processes on the removal of N-Cl-DCAM precursors was found to be unsatisfactory due to their poor performance in the removal of low molecular weight (MW) or non-polar organics. In the ozonation integrated with biological activated carbon (O3-BAC) process, the ozonation had little influence on the decrease of N-Cl-DCAM FP. The removal efficiency of precursors by a new BAC filter, in which the granular activated carbon (GAC) had only been used for four months was higher than that achieved by an old BAC filter in which the GAC had been used for two years. The different removal efficiencies of precursors were mainly due to the different adsorption capacities of GAC for individual precursors. Low MW or non-polar organics were predominantly removed by GAC, rather than biodegradation by microorganisms attached to GAC particles.  相似文献   

17.
• Nanowire-assisted LEEFT is applied for water disinfection with low voltages. • LEEFT inactivates bacteria by disrupting cell membrane through electroporation. • Multiple electrodes and device configurations have been developed for LEEFT. • The LEEFT is low-cost, highly efficient, and produces no DBPs. • The LEEFT can potentially be applicable for water disinfection at all scales. Water disinfection is a critical step in water and wastewater treatment. The most widely used chlorination suffers from the formation of carcinogenic disinfection by-products (DBPs) while alternative methods (e.g., UV, O3, and membrane filtration) are limited by microbial regrowth, no residual disinfectant, and high operation cost. Here, a nanowire-enabled disinfection method, locally enhanced electric field treatment (LEEFT), is introduced with advantages of no chemical addition, no DBP formation, low energy consumption, and efficient microbial inactivation. Attributed to the lightning rod effect, the electric field near the tip area of the nanowires on the electrode is significantly enhanced to inactivate microbes, even though a small external voltage (usually<5 V) is applied. In this review, after emphasizing the significance of water disinfection, the theory of the LEEFT is explained. Subsequently, the recent development of the LEEFT technology on electrode materials and device configurations are summarized. The disinfection performance is analyzed, with respect to the operating parameters, universality against different microorganisms, electrode durability, and energy consumption. The studies on the inactivation mechanisms during the LEEFT are also reviewed. Lastly, the challenges and future research of LEEFT disinfection are discussed.  相似文献   

18.
• Bacterial release from aged pipe sections under extreme conditions was quantified. • Released bacterial community structure exhibited large variation after transition. • Risks from transition reduced significantly with cleaner source. As a result of pollution in the present water sources, cities have been forced to utilize cleaner water sources. There are few reports regarding the potential shift of bacterial community structure driven by water source switching, especially that of corrosion-related bacteria. Three types of finished water were used for simulation, the polluted source water from the Qiantang and Dongtiaoxi Rivers (China) was replaced by cleaner water from Qiandao Lake (China). Here, we discussed the transition effects through three simulated reactors. The bacterial characteristics were identified using the high-throughput sequencing and heterotrophic plate count method. It was observed that the level of culturable bacteria declined by 2–3 orders of magnitude after water source switching. The bacterial community released from the pipeline reactor was significantly different under different finished water, and it exhibited large variation at the genus level. Porphyrobacter (58.2%) and Phreatobacter (14.5%) clearly replaced Novosphingobium, Aquabacterium, and Cupriavidus as new dominant genera in system A, which could be attributed to the lower carbon and nitrogen content of the new water source. Although corrosion-inhibiting bacteria decreased after switching, they still maintained dominant in three reactors (6.6%, 15.9%, and 19.7%). Furthermore, potential opportunistic pathogens such as Sphingomonas were detected. Our study shows that after transition to a high quality water source, the total culturable bacteria released was in a downtrend, which leads to a great reduction in the risk of bacterial leakage in the produced drinking water.  相似文献   

19.
• A V2O5/TiO2 granular catalyst for simultaneous removal of NO and chlorobenzene. • Catalyst synthesized by vanadyl acetylacetonate showed good activity and stability. • The kinetic model was established and the synergetic activity was predicted. • Both chlorobenzene oxidation and SCR of NO follow pseudo-first-order kinetics. • The work is of much value to design of multi-pollutants emission control system. The synergetic abatement of multi-pollutants is one of the development trends of flue gas pollution control technology, which is still in the initial stage and facing many challenges. We developed a V2O5/TiO2 granular catalyst and established the kinetic model for the simultaneous removal of NO and chlorobenzene (i.e., an important precursor of dioxins). The granular catalyst synthesized using vanadyl acetylacetonate precursor showed good synergistic catalytic performance and stability. Although the SCR reaction of NO and the oxidation reaction of chlorobenzene mutually inhibited, the reaction order of each reaction was not considerably affected, and the pseudo-first-order reaction kinetics was still followed. The performance prediction of this work is of much value to the understanding and reasonable design of a catalytic system for multi-pollutants (i.e., NO and dioxins) emission control.  相似文献   

20.
• Impact of urban development on water system is assessed with carrying capacity. • Impacts on both water resource quantity and environmental quality are involved. • Multi-objective optimization revealing system trade-off facilitate the regulation. • Efficiency, scale and structure of urban development are regulated in two stages. • A roadmap approaching more sustainable development is provided for the case city. Environmental impact assessments and subsequent regulation measures of urban development plans are critical to human progress toward sustainability, since these plans set the scale and structure targets of future socioeconomic development. A three-step methodology for assessing and optimizing an urban development plan focusing on its impacts on the water system was developed. The methodology first predicted the pressure on the water system caused by implementation of the plan under distinct scenarios, then compared the pressure with the carrying capacity threshold to verify the system status; finally, a multi-objective optimization method was used to propose regulation solutions. The methodology enabled evaluation of the water system carrying state, taking socioeconomic development uncertainties into account, and multiple sets of improvement measures under different decisionmaker preferences were generated. The methodology was applied in the case of Zhoushan city in South-east China. The assessment results showed that overloading problems occurred in 11 out of the 13 zones in Zhoushan, with the potential pressure varying from 1.1 to 18.3 times the carrying capacity. As a basic regulation measure, an environmental efficiency upgrade could relieve the overloading in 4 zones and reduce 9%‒63% of the pressure. The optimization of industrial development showed that the pressure could be controlled under the carrying capacity threshold if the planned scale was reduced by 24% and the industrial structure was transformed. Various regulation schemes including a more suitable scale and structure with necessary efficiency standards are provided for decisionmakers that can help the case city approach a more sustainable development pattern.  相似文献   