首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Incremental lifetime health risks due to polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) emitted from municipal waste incineration (MSWI) facilities were evaluated for resident population in the area of the plant. Risk assessment was performed through a multipathway combined probabilistic/deterministic approach for analyzing the effects of uncertainty and intrinsic variability of the main PCDD/F emission related parameters on final predicted values. Exposure through direct inhalation of contaminated air, soil ingestion, soil dermal contact and diet were considered, with the propagation of the variability of input parameters throughout the evaluation performed with Monte Carlo simulation techniques. The application to a case study representative of two different technological scenarios (modern facilities equipped with BAT - Best Available Technology - and older incinerators) in a location site typical of Northern Italy situation results in median values of the maximum individual excess risk on the order of 10(-9) and 10(-7) for most recent and older plant configurations, respectively. Corresponding ratios for the 90th and 10th percentile values are around 7 and 9. Individual risk estimates derived for the same scenarios from conventional deterministic approaches, where large conservative assumptions are normally adopted for compensating the lack of knowledge about uncertainty, are essentially comparable with maximum values resulting from the probabilistic approach, thus leading to situations with extreme and very low probabilities of occurrence. PCDD/F health risks from MSWI emissions might thus result largely overestimated if real emission characteristics are not properly considered in the assessment procedure. Sensitivity analysis for identifying the contribution of different input parameters on final predicted risk variance indicates, for the area considered in the simulation, a prevailing influence of PCDD/F stack concentration, with exposures arising from soil deposition phenomena substantially negligible: this latter result further points out the requirements for a very careful identification of base input data values for PCDD/F stack concentrations, at least for those situations where plants are located nearby urban areas.  相似文献   

2.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

3.
Cheng PS  Hsu MS  Ma E  Chou U  Ling YC 《Chemosphere》2003,52(9):1389-1396
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in twenty-one ambient air samples, eight soil samples and two stack gas samples, collected near or in a municipal solid waste incinerator (MSWI) in Hsinchu, Taiwan. A systematic decrease of PCDD/Fs in the ambient air from the northeastern area was observed. PCDD/Fs levels measured in the ambient air range from 0.058 to 0.127 pg-TEQ/m3. Higher PCDD/Fs levels in the ambient air were found during winter. In addition, PCDD/Fs levels measured in the soil range from 0.524 to 5.02 pg-TEQ/g d.m. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) did not provide sufficient evidence that the environmental PCDD/Fs contamination was caused by emissions from the Hsinchu MSWI. An unknown PCDD/Fs source was proposed using congener profile analysis and supported by both PCA and HCA.  相似文献   

4.
Emission of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) by municipal solid waste incinerators (MSWI) is an issue of great concern. In 1997, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an MSWI from Tarragona (Catalonia, Spain). As a result, PCDD/F emissions were significantly reduced. The aim of this study was to determine the current levels of PCDD/Fs in soil and vegetation samples collected near the facility and to compare these levels with those obtained in previous surveys (1996 and 1997). In the period 1997-1999, PCDD/F concentrations in vegetation samples were significantly decreased (60%). By contrast, the levels of PCDD/Fs in soil samples increased slightly (14%, P > 0.05) during the same period. An exhaustive analysis of the present data indicates that other emission sources of PCDD/Fs have also a notable environmental impact on the area under direct influence of the MSWI.  相似文献   

5.
Recently, we measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in soil and herbage samples collected in the vicinity of a municipal solid waste incinerator (MSWI) from Tarragona (Catalonia, Spain). Since these concentrations could be increased by the presence of other emission sources of PCDD/Fs in the same area in which the MSWI is placed, the main goal of the present study was to determine the PCDD/F congener profiles in the soil and vegetation samples collected in 1996 and again in 1997 near to the facility and to compare with those from samples collected in a close area outside of direct emissions of the plant. From an accurate inspection of the PCDD/F congener profiles, it was concluded that PCDD/F emissions from the MSWI here examined are neither the only nor the main responsible for the presence of PCDD/Fs in the samples of environmental matrices collected in the area under direct influence of the plant.  相似文献   

6.
Floret N  Lucot E  Badot PM  Mauny F  Viel JF 《Chemosphere》2007,68(8):1419-1426
Since 1971, a municipal solid waste incinerator (MSWI) with high dioxin emission levels has been in operation in Besan?on, France. We recently found a 2.3-fold risk of non-Hodgkin's lymphoma in the highest exposure zone using a Gaussian-type dispersion model as a proxy for dioxin exposure. However, the sources of PCDD/Fs in this area are a matter of controversy. The aim of this survey was therefore to examine the nature of the PCDD/F soil contamination in the surroundings of the MSWI to characterize whether more than one potential emission source could explain the presence of the PCDD/Fs. PCDD/F congener profiles were determined in 75 soil samples collected in the vicinity of the MSWI. They were compared according to the most environmentally impacted zones and to various spatial contrasts. PCDD/F concentrations ranged from 0.25 to 28.06 pg WHO-TEQ g(-1). Two different clustering algorithms identified the same main cluster (consisting of 73 samples). The remaining two soil samples composed either one, or two clusters. All clusters showed similar congener profiles. Moreover, no contrast was observed for congener distributions between complex and simple topographies, inside and outside the city boundary, the two most and the two least exposed areas, reflecting a common fingerprint. Congener profiles indicate that the area under influence of the MSWI is not subject to other point sources of PCDD/Fs. Since, the most polluting combustion chambers were recently shut down and replaced by a new one with up-to-date pollution control, slowly decreasing dioxin concentrations in the soils are to be expected.  相似文献   

7.
8.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

9.
Levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in both air and soil samples were measured at three different sites in Italy, in proximity to three municipal solid waste incinerators (MSWIs) to determine baseline contamination and the contributory role of incinerator emissions. At the first site, located in an agricultural, cattle-breeding, typically flattish area of the Po Valley, the dioxin concentrations had already been measured before the start-up of the new MSWI. These dioxin concentrations were then again measured after two years of continual operation of the incinerator. Despite the presence of the plant, the PCDD/Fs concentrations appear not to have been affected and were found to be in a range of 22-125 fg I-TEQ m(-3) in the air samples and 0.7-1.5 pg I-TEQ g(-1) in the soil samples. The second site is located in an industrial district of the Veneto Region, in the surroundings of an old MSWI that is not equipped with Best Available Technology (BAT) dioxin removal system. The PCDD/Fs concentrations in the air samples were between 144 and 337 fg I-TEQ m(-3). This is a typical range of values for industrial areas, while the soil samples showed contamination levels between 1.1 and 1.4 pg I-TEQ g(-1). The third site lies in the Adige Valley, near a MSWI that has been equipped with BAT for flue gas cleaning. The observed values ranged from 10 to 67 fg I-TEQ m(-3) for the air samples and 0.08-1.2 pg I-TEQ g(-1) for the soil samples. The contributory factors of the varying characteristics of the different areas together with the types of technology adopted at each MSWI plant are discussed. The PCDD/Fs levels are subsequently compared with established values from previous studies.  相似文献   

10.
In 2005 and 2006, the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs) and metals (As, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sn, Tl and V) were measured in air samples collected in an industrial area of Sant Adrià del Besòs (Barcelona, Catalonia, Spain) where a municipal solid waste incinerator (MSWI) is placed, and in a background/control area. In general terms, concentrations of all environmental pollutants were higher at the industrial site. No significant seasonal/temporal variations were observed in any of the areas. No Pearson correlation was found between the PCDD/F concentrations and the environmental conditions of the two sampling periods considered. Principal component analyses (PCA) were performed to get information on the relationship among samples, pollutants, and emission sources. The results indicate that the MSWI of S. Adrià de Besòs is not a significant emission source of the above compounds for the area under its direct influence. Moreover, a notable difference in the PCDD/F congener profiles was found between ambient air and stack gas emissions, indicating that the current levels of PCDD/Fs are more related to other potential emissions sources rather than to those from the MSWI.  相似文献   

11.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

12.
Polychlorinated dibenzo-p-dioxin (PCDD) and polychlorinated dibenzofuran (PCDF) levels were determined in adipose tissue of 15 autopsied subjects who at the time of death had lived in the city of Tarragona (Catalonia, Spain) and surroundings during at least the last 10 years. PCDD/F concentrations ranged between 13.37 and 69.37 ng I-TEQ/kg fat, with mean and median values of 30.98 and 26.30 ng I-TEQ/kg fat, respectively. PCDD/F concentrations were higher (p < 0.01) in women (mean value: 44.95 ng I-TEQ/kg fat) than in men (mean value: 24.00 ng I-TEQ/kg fat). Although individuals living in industrial areas showed higher PCDD/F levels than those living Tarragona downtown the difference was not statistically significant. When Principal Component Analysis was applied to the concentrations of PCDD/Fs found in the 15 adipose tissue samples together with those found in 20 blood samples collected in a previous study, a single two-dimensional model was obtained, which would explain 62.9% of the variance in the data. The PCDD/F concentrations in adipose tissue found in the current study are of the same order of magnitude than those reported for most industrialized countries.  相似文献   

13.
This study was designed to evaluate soil and air (gas and particle) transfer of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to vegetation in residential and industrial areas. In a first part, soil-vegetation transfer was assessed. The levels of PCDD/Fs in 120 soil and 120 herbage samples collected from 1996 to 2002 in an industrial area of Montcada (Barcelona, Spain), near a municipal solid waste incinerator (MSWI), were determined. Some additional individual samples were also evaluated. It was concluded that high soil concentrations, which are not at steady state with the air layer above it, show a tendency for PCDD/Fs to escape via volatilization. In a second part of the study, air-vegetation transfer was examined. PCDD/F concentrations from 24 herbage samples were used, while PCDD/F concentrations were also measured in seven high-volume air samples and seven passive air-vapor samples. Scavenging coefficients (m3 air "sampled"/g grass d.m.) ranged from 1.9 to 11.3 m3/g. A good trend with K(OA) was observed for PCDDs (R=0.82), while it was lower for PCDFs (R=0.55). The current results corroborate that PCDD/F concentrations in vegetation are associated with atmospheric deposition. For the highest substituted PCDD/F congeners, the air-particle uptake from plants is the principal pathway. In regions impacted by combustion emission sources, PCDD/F gas-particle partitioning is influenced by a higher concentration of particles in the air. Particles and associated particle-bound PCDD/Fs would sorb to leaf surfaces, and are subject to removal via wash off. However, in areas where emissions to air are not very notable, vapor absorption would be the principal source of vegetation pollution. The results of this investigation can have a potential interest in risk assessment studies and environmental fate models.  相似文献   

14.
The stack gases of a municipal solid waste incinerator (MSWI), and ambient air were sampled in four locations around the plant for the analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs). The sampling area was close to an industrial area near Trieste, in north-east Italy. The purpose of the study was to estimate the impact of the MSWI emissions and to distinguish the contribution of these emissions from other potential emission sources in the industrial area.PCDD/F atmospheric concentrations were similar to those generally detected in urban–rural areas with one location about 2–3 times more contaminated than the others. Since the most contaminated location was inside the industrial area but upwind of the MSWI, principal component analysis (PCA) was used to establish whether other sources were the cause. This analysis clearly showed that a local steel plant’s emission was the main source of PCDDs/Fs in ambient air. This study highlights the usefulness of multivariate data analysis such as PCA to identify, among different potential emission sources, the one really responsible for the contamination.  相似文献   

15.
Xu MX  Yan JH  Lu SY  Li XD  Chen T  Ni MJ  Dai HF  Cen KF 《Chemosphere》2008,71(6):1144-1155
Isomer-specific data were investigated in order to identify the sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in agricultural soils, including Fluvo-aquic and paddy soils, in the vicinity of a Chinese municipal solid waste incineration (MSWI) plant. Homologue and isomer profiles of PCDD/Fs in soils were compared with those of potential sources, including combustion sources, i.e., MSWI flue gas and fly ash; and the impurities in agrochemicals, such as the pentachlorophenol (PCP), sodium pentachlorophenate (PCP-Na) and 1,3,5-trichloro-2-(4-nitrophenoxy) benzene (CNP). The results showed that the PCDD/F isomer profiles of combustion sources and agricultural soils were very similar, especially for PCDFs, although their homologue profiles varied, indicating that all the isomers within each homologue behave identically in the air and soil. Moreover, factor analysis of the isomer compositions among 33 soil samples revealed that the contamination of PCDD/Fs in agricultural soils near the MSWI plant were primarily influenced by the combustion sources, followed by the PCP/PCP-Na and CNP sources. This implication is consistent with our previous findings based on chemometric analysis of homologue profiles of soil and flue gas samples, and identifies PCP/PCP-Na as an additional important source of PCDD/Fs in the local area. This makes the similarities and differences of isomer profiles between Fluvo-aquic and paddy soils more explainable. It is, therefore, advisable to use isomer-specific data for PCDD/F source identifications where possible.  相似文献   

16.
Congener profiles are the fractional distribution of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) congeners in an environmental release, or in an environmental or biological sample. In 1999, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an old municipal solid waste incinerator (MSWI) from Montcada (Barcelona, Spain). The main goal of the present study was to determine if the environmental PCDD/F levels in the area under direct influence of the facility were mainly due to PCDD/F emissions from the plant. For this purpose, soil and herbage samples were collected near the MSWI before (1998) and after (2000) the technical improvements were performed. PCDD/F congener profiles were determined and compared with those from samples collected in a suburban area of Constantí (Tarragona, Spain) outside of direct emissions from any MSWI. The results of the present study suggest that the MSWI here assessed is not the main responsible for the environmental PCDD/F concentrations in the area under evaluation. Other PCDD/F emission sources in the same area seem also to have a notable impact on the atmospheric levels of these pollutants.  相似文献   

17.
In April 1996 and 1998, the concentrations of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in 40 herbage samples collected in the neighborhood of a hazardous waste incinerator (HWI) under construction in Constanti (Catalonia, Spain). In April 2000, 20 months after the HWI began operating, herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. PCDD/F concentrations ranged between 0.13 and 0.65 ng I-TEQ/kg (dry matter), with a median and mean values of 0.29 and 0.32 ng I-TEQ/kg (dry matter), respectively. The results were compared with those obtained in the 1996 (median, 0.53 ng I-TEQ/kg; mean, 0.61 ng I-TEQ/kg) and the 1998 (median, 0.23 ng I-TEQ/kg; mean, 0.31 ng I-TEQ/kg) surveys. While in the period 1996-1998 a significant decrease (49%, P < 0.001) in the mean PCDD/F levels was noted, in the period 1998-2000 an increase of 3% (P > 0.05) was found in the concentrations of PCDD/Fs. The analysis of the results suggests two potential hypotheses: either the emissions of PCDD/Fs from the HWI are not negligible, or the current PCDD/F emissions from other sources near the HWI remained at similar levels to those reached in 1998. Anyhow, an exhaustive evaluation of the present data shows an absence of notable PCDD/F contamination by the HWI in the area under its direct influence. It seems also probable that the decline in the atmospheric levels of PCDD/Fs due other emission sources of PCDD/Fs in this area is currently stopped.  相似文献   

18.
To assess the influence of a new hazardous waste incinerator (HWI) on public health, a preoperational monitoring program was established during the period of construction. In this study, the levels of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) accumulated in adipose tissue of 15 autopsied subjects living in the area under potential impact of the HWI were determined after approximately 3 years of regular operations in the facility. The non-ortho PCBs 77, 126 and 169 were also determined. PCDD/F concentrations ranged between 1.5 and 41 pg WHO-TEQ/g fat (2.4 and 72 WHO-TEQ/g fat, respectively, including PCBs), with a mean value of 11 pg WHO-TEQ/g fat and a median value of 7.4 pg WHO-TEQ/g fat (22 and 13 WHO-TEQ/g fat, respectively, including PCBs). In the baseline study, the mean level of PCDD/Fs was 36 pg WHO-TEQ/g fat (61 pg WHO-TEQ/g fat, including non-ortho PCBs 77, 126 and 169), which means a reduction of 70% (64% including PCBs). This notable reduction is in accordance with the important decrease observed in recent years in PCDD/F intake through the diet. The current concentrations of PCDD/Fs in human adipose tissue, as well as recent data on PCDD/F levels in plasma and breast milk of subjects living in the vicinity of the same HWI, indicate that there is not any additional significant exposure to PCDD/Fs for this population.  相似文献   

19.
Emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alkene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alkenes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

20.
The production of cement in China is accompanied by various emissions, such as fine particulate matter, heavy metals, nitrogen oxides, sulfur oxides, carbon dioxide…. Moreover, cement kiln presents a potential health risk to its surroundings, linking to emissions of persistent organic pollutants (POPs), such as polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), in brief dioxins. Flue gas samples were collected from five typical cement kilns during twelve runs and were used to evaluate the levels and distribution of PCDD/Fs in the emissions from cement kilns. The PCDD/Fs concentrations (136 congeners) and I-TEQ values ranged from 2.3 to >40 ng/m3 and 9.3?~?90.8?×?10?3 ng I-TEQ/m3, respectively, which were lower than the emission standard in China (0.1 ng I-TEQ/m3). In weight units, the dominant congeners were OCDD, 1,2,3,4,6,7,8-HpCDF, and OCDF; 2,3,4,7,8-PeCDF is the largest contributor (36–66 %) to the total I-TEQ value of twelve runs. HxCDF and TCDF were the first two most abundant homologue groups (12–85 and 4–52 %), and the homologue concentration decreased with rising chlorine number for PCDDs. In addition, there was no marked difference in homologue profiles when solid wastes (refuse-derived fuel and municipal solid waste) and hazardous wastes (DDT and POPs) were combusted as supplemental fuels. The use of various supplemental fuels had no obvious effect on the fingerprint of PCDD/F homologues. Moreover, there was no significant difference in levels of PCDD/Fs emission due to the diversity of production capacity, which were consistent with reported previously. Air pollution control device had effect on the homologue profiles, and cement system with electrostatic precipitators (ESP) had more fractions of octachloro congeners to the total.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号