首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
During a monitoring campaign concentrations of volatile organic compounds (VOCs) were measured in indoor air of 79 dwellings where occupants had not complained about health problems or unpleasant odour. Parameters monitored were the individual concentration of 68 VOCs and the total concentration of all VOCs inside the room. VOCs adsorbed by Tenax TA were then analysed by means of thermal desorption, gas chromatography and mass spectrometry. The analytical procedure and quantification was done according to the recommendation of the ECA-IAQ Working Group 13 which gave a definition of the total volatile organic compound (TVOC) concentration. Using this recommendation TVOC-concentrations ranged between 33 and 1600 microg m(-3) with a median of 289 microg m(-3). Compounds found in every sample and with the highest concentrations were 2-propanol, alpha-pinene and toluene. Save for a few samples, all concentrations measured have been a factor 2 to 10 lower, compared to data from similar studies. Only a few terpenes and aldehydes were found exceeding published reference data or odour threshold concentrations. However, it has been found that sampling and analysing methods do have a considerable impact on the results, making direct comparisons of studies somewhat questionable. 47% of all samples revealed concentrations exceeding the threshold value of 300 microg TVOC m(-3) set by the German Federal Environmental Agency as a target for indoor air quality. Using the TVOC concentration as defined in the ECA-IAQ methodology is instrumental in assessing exposure to VOCs and identifying sources of VOCs. The background concentrations determined in this study can be used to discuss and interpret target values for individual and total volatile organic compounds in indoor air.  相似文献   

2.
It is well established that some areas of Himachal Pradesh (H.P.) state of India situated in the environs of the Himalayan mountains are relatively rich in uranium-bearing minerals. Some earlier studies by our group have indicated high levels of radon (>200 Bq m(-3)) in the dwellings. It is in this context that an indoor radon/thoron survey has been carried out in selected villages of four districts in the state of H.P. This survey has been conducted as a part of a national, coordinated project using twin chamber dosemeter cups designed by the Environmental Assessment Division (EAD), Department of Atomic Energy, Govt. of India. The track-etch technique is used for calibration of plastic detector LR-115 type-II which are employed for recording alpha tracks due to radon/thoron and their daughters. Year long radon/thoron data have been collected for seasonal correlations of indoor radon/thoron in the dwellings. The indoor radon levels have been found to vary from a minimum value of 17.4 Bq m(-3) to a maximum value of 140.3 Bq m(-3). The indoor thoron levels vary from a minimum value of 5.2 Bq m(-3) to a maximum value of 131.9 Bq m(-3). The year average dose rate for the local population varies from 0.03 microSv h(-1) to 0.83 microSv h(-1). The annual exposure dose to inhabitants in all the dwellings lies below the upper limit of 10 mSv given in ICRP-65.  相似文献   

3.
A new, analytically valid procedure is described to assess the exposure of human beings to the so-called microbial volatile organic compounds (MVOCs) in air. The method can be used routinely for large sample numbers and is especially valuable as a basis for further research on the correlation between single MVOCs and indoor mould growth. The procedure is based on the fact that fungi produce a variety of volatile organic compounds, such as 3-methylbutan-1-ol, 3-methylbutan-2-ol, fenchone, heptan-2-one, hexan-2-one, octan-3-one, octan-3-ol, pentan-2-ol, alpha-terpineol, and thujopsene, which they emit into the indoor environment. Using diffusive samplers, these MVOCs are adsorbed onto charcoal during a sampling interval of four weeks. The described method is thus superior to existing methods which use short-term active sampling. After desorption with carbon disulfide, the MVOCs were determined by dual-column gas chromatography with flame ionization detection using the large-volume injection technique for sample introduction. The detection limits ranged between 0.15 and 0.53 microgram m-3, within-series precision was found to range between 6.5 and 19.0%, and recovery was between 77 and 118%. The procedure has been successfully applied in the context of a large field study to measure the indoor MVOC exposure in children's rooms of 132 dwellings. The objective of the study was to examine the relation between indoor mould growth, the indoor MVOC exposure and the prevalence of adverse health effects. Information about mould formation has been obtained by a questionnaire and by the determination of colony forming units of mould fungi in mattress dust. With the exception of 3-methylbutan-2-ol, fenchone, nonan-2-one, octan-2-one, and thujopsene, indoor air concentrations of all MVOCs under investigation were significantly higher inside damp and mouldy dwellings. From the primary MVOCs under investigation, 3-methylbutan-1-ol, hexan-2-one, heptan-2-one, and octan-3-ol were found to be most reliable indicators for mould formation. A correlation was also found between selected MVOCs and the occurrence of mould species in mattress dust. Aspergillus sp. correlated with heptan-2-one, hexan-2-one, octan-3-ol, octan-3-one, and alpha-terpineol, while the occurrence of Eurotium sp. was correlated with higher indoor air concentrations of 3-methylbutan-1-ol, 3-methylbutan-2-ol, heptan-2-one, hexan-2-one, octan-3-ol, and thujopsene. Children living in dwellings with elevated MVOC levels had a higher prevalence of asthma, hay fever, wheezing, and irritations of the eyes. These positive associations persisted after controlling for confounding factors such as age, sex, body-mass index, number of siblings, social status, passive smoking, type of heating, and ventilation habits. However, they were not statistically significant. This lack of significance may be a result of the small number of investigated samples.  相似文献   

4.
The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium–low level of bacterial contamination (50–500 CFU/m3) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.  相似文献   

5.
A temporary renovation activity releases considerably high concentrations of particulate matter, viable and non-viable, into air. These pollutants are a potential contributor to unacceptable indoor air quality (IAQ). Particulate matter and its constituents lead, sulfate, nitrate, chloride, ammonium and fungi as well as fungal spores in air were evaluated in a building during renovation action. Suspended dust was recorded at a mean value of 6.1 mg m(-3) which exceeded the Egyptian limit values for indoor air (0.15 mg m(-3)) and occupational environments (5 mg m(-3)). The highest particle frequency (23%) of aerodynamic diameter (dae) was 1.7 microm. Particulate sulfate (SO(4)(2-)), nitrate (NO(3)(-)), chloride (Cl(-)), ammonium (NH(4)(+)) and lead components of suspended dust averaged 2960, 28, 1350, 100 and 13.3 microg m(-3), respectively. Viable fungi associated with suspended dust and that in air averaged 1.11 x 10(6) colony forming unit per gram (cfu g(-1)) and 92 colony forming unit per plate per hour (cfu p(-1) h(-1)), respectively. Cladosporium(33%), Aspergillus(25.6%), Alternaria(11.2%) and Penicillium(6.6%) were the most frequent fungal genera in air, whereas Aspergillus(56.8%), Penicillium(10.3%) and Eurotium(10.3%) were the most common fungal genera associated with suspended dust. The detection of Aureobasidium, Epicoccum, Exophiala, Paecilomyces, Scopulariopsis, Ulocladium and Trichoderma is an indication of moisture-damaged building materials. Alternaria, Aureobasidium, Cladosporium, Scopulariopsis and Nigrospora have dae > 5 microm whereas Aspergillus, Penicillium and Verticillium have dae < 5 microm which are suited to penetrate deeply into lungs. Particulate matter from the working area infiltrates the occupied zones if precautionary measures are inadequate. This may cause deterioration of IAQ, discomfort and acute health problems. Renovation should be carefully designed and managed, in order to minimize degradation of the indoor and outdoor air quality.  相似文献   

6.
The paper presents the results of radon concentration measurements in the vicinity of water, indoor air and in contact to building walls. The investigations were carried out using CR-39 track detectors. Samples of ground water flowing out of many springs mostly in Arabian Gulf area except one from Germany have been studied. The results are compared with international recommendations and the values are found to be lower than the recommended value. Measuring the mean indoor radon concentrations in air and in contact to building walls in the dwellings of Kuwait University Campus were found 24.2 +/- 7.7, and 462 +/- 422 Bq m(-3) respectively. These values lead to average effective dose equivalent rates of 1.3 +/- 0.4 and 23 +/- 21 mSv year(-1), respectively.  相似文献   

7.
Good indoor air quality (IAQ) in buildings provides a comfortable and healthy environment for the occupants to work, learn, study, etc. Therefore, it is important to ascertain the IAQ status in the buildings. This study is aimed to establish and demonstrate the comprehensive IAQ audit approach for public buildings, based on Portugal national laws. Four public buildings in Portugal are used to demonstrate the IAQ audit application. The systematic approach involves the measurement of physical parameters (temperature, relative humidity, and concentration of the suspended particulate matter), monitoring of the concentrations of selected chemical indicators [carbon dioxide (CO2), carbon monoxide, formaldehyde, ozone, and total volatile organic compounds], and the measurements of biological indicators (bacteria and fungi). In addition, air exchange rates are measured by the concentration decay method using metabolic CO2 as the tracer gas. The comprehensive audits indicated some situations of common IAQ problems in buildings, namely: (1) insufficient ventilation rate, (2) too high particle concentration; and (3) poor filtration effectiveness and hygienic conditions in most of the air handling units. Accordingly, a set of recommendations for the improvement of IAQ conditions were advised to the building owner/managers.  相似文献   

8.
This paper presents key elements on which to base the design of a strategy for a particular indoor environment measurement task. Starting from a general strategy for responding to occupant complaints and conducting epidemiological and intervention studies the paper concentrates on selected key elements, with focus on air contaminants. Strategies for grouping of occupants with the purpose of exposure assessment should aim at optimising exposure contrast between groups, and grouping according to buildings may not be the proper choice. Occupant exposure can be measured by personal sampling or constructed from measured concentrations in microenvironments and activity patterns. The cause of temporal and spatial variability is discussed and guidance is given on the number of samples needed to detect a given change in true concentration level. The sick building syndrome (SBS) is defined as those situations where a high proportion of building occupants are complaining about mucous membrane or skin irritation, general symptoms. When investigating SBS, questionnaires should be used to collect structured information from occupants on perception of environmental conditions, psychosocial factors and symptoms. There is as yet no consensus on choice of length of reference period for reporting symptoms and for estimating exposure. Finally, methods for identifying and quantification of sources of air contaminants are discussed, including lab-scale or full-scale simulation, on-site measurement of source emission, air monitoring, surface sampling, and modelling.  相似文献   

9.
Our group previously demonstrated that carbon dioxide (CO2) levels in heavily occupied schools correlate with the levels of airborne bacterial markers. Since CO2 is derived from the room occupants, it was hypothesized that in schools, bacterial markers may be primarily increased in indoor air because of the presence of children; directly from skin microflora or indirectly, by stirring up dust from carpets and other sources. The purpose of this project was to test the hypothesis. Muramic acid (Mur) is found in almost all bacteria whereas 3-hydroxy fatty acids (3-OH FAs) are found only in Gram-negative bacteria. Thus Mur and 3-OH FA serve as markers to assess bacterial levels in indoor air (pmol m(-3)). In our previous school studies, airborne dust was collected only from occupied rooms. However, in the present study, additional dust samples were collected from the same rooms each weekend when unoccupied. Samples were also collected from outside air. The levels of dust, Mur and C10:0, C12:0, C14:0, and C16:0 3-OH FAs were each much higher (range 5-50 fold) in occupied rooms than in unoccupied school rooms. Levels in outdoor air were much lower than that of indoor air from occupied classrooms and higher than the levels in the same rooms when unoccupied. The mean CO2 concentrations were around 420 parts per million (ppm) in unoccupied rooms and outside air; and they ranged from 1017 to 1736 ppm in occupied rooms, regularly exceeding 800-1000 ppm, which are the maximum levels indicative of adequate indoor ventilation. This indicates that the children were responsible for the increased levels of bacterial markers. However, the concentration of Mur in dust was also 6 fold higher in occupied rooms (115.5 versus 18.2 pmole mg(-1)). This further suggests that airborne dust present in occupied and unoccupied rooms is quite distinct. In conclusion in unoccupied rooms, the dust was of environmental origin but the children were the primary source in occupied rooms.  相似文献   

10.
Pet allergens and mold growth related to damp are common phenomena in day care centers in Sweden but exposure measurements of these factors are lacking. The aim of this study was to investigate the relationship between building construction and indoor environment quality in Swedish day care centers and the potential for exposure to fungi (analyzed by quantitative PCR) and animal allergens (analyzed by ELISA). Measurements were performed in 21 day care centers (103 rooms) from one municipality in Sweden, which were identified as constructions at risk of dampness (85% of the buildings) and with visible damage and mold growth (54% of the buildings). Dust samples were collected using cotton swab and Petri dishes. Total fungal DNA was detected in 99% and 100%, Aspergillus/Penicillium DNA in 54% and 68%, and Stachybotrys chartarum DNA in 4% and 9% of the investigated rooms in cotton swab and Petri dish samples, respectively. The total fungal DNA levels (Geometric Mean, GM) were 4.2 × 10(6) cell equivalents per m(2) and 2.9 × 10(5) cell equivalents per m(2) per day in the swab and Petri dish samples, respectively. The concentrations (GM) of cat (Fel d1), dog (Can f1), and horse (Equ cx) allergens were 9.4, 7.2 ng m(-2) day(-1), and 5.0 unit per m(2) per day, respectively. Total fungal DNA levels were higher in risk construction buildings (p = 0.01), in rooms with linoleum flooring material (p = 0.003), and in buildings with rotating heat exchangers (p = 0.02). There were associations between total fungal DNA levels and cat (p = 0.02), dog (p < 0.001), and horse (p = 0.001) allergens. In conclusion, risk constructions, damp constructions, mould growth, fungal DNA, and animal allergens were common exposure factors in Swedish day care centers. Building constructions that represent a high risk for internal dampness should be avoided in the future, and measures to reduce allergen levels should be considered to protect pet-allergic children from asthmatic problems.  相似文献   

11.
Most of the building materials contain naturally occurring radioactive elements, the most important of which are potassium 40K and the members of two natural radioactive series, which can be represented by the isotopes of thorium 232Th and Uranium 238U. The presence of these radioisotopes in the materials causes external exposure to the people who live in the building. In addition, the disintegration of Uranium 238U increases the concentration of radon gas 222Rn and of its daughters in the house. So a systematic indoor gamma dose measurement has been performed in the dwellings of Agastheeswaram Taluk of Kanyakumari district, which is lying within the 30 km radius from the upcoming Kudankulam nuclear power plant site. The geometric mean of annual absorbed dose from gamma radiation in dwellings has been found to be 278 nGyh−1. The seasonal variation of indoor gamma dose measurements has also been studied. Significant differences have been observed in dwellings built of different materials such as concrete, tiled, etc.  相似文献   

12.
We examined the selectivity of 53 sets of primers for environmental monitoring of indoor air quality. Thirty-six fungal strains, representing 26 species from 14 genera of commonly occurring fungi, and 16 different bacterial strains, representing both gram-negative and gram-positive species, were included in the experiment. We verified the specificity of 28 of the 53 sets of primers, which were classified as universal fungal, universal bacterial, group or species specific. The PCR conditions required for optimal specificity were also determined. These results can serve as a guide for the step-wise PCR-based detection and identification of airborne fungi commonly found in indoor environments.  相似文献   

13.
To study the distribution of Aspergillus spp. in outdoor and indoor air of asthmatic patients’ houses, as well as a review on the health effects of exposure to indoor Aspergillus. Open plates containing malt extract agar media were used to isolate fungi from the indoor (n?=?360) and outdoor (n?=?180) air of 90 asthmatic patients’ houses living in Sari City, Iran. Plates were incubated at room temperature for 7–14 days. Cultured Aspergillus spp. were identified by standard mycological techniques. All culture plates grew fungi, a testament to the ubiquitous nature of fungal exposure. Cladosporium spp. (29.2%), Aspergillus spp. (19.0%), and Penicillium spp. (18.3%) were most common inside the houses while Cladosporium spp. (44.5%), Aspergillus spp. (12.4%), and Alternaria spp. (11.1%) were most common outside the houses. Aspergillus flavus (30.1%) and A. fumigatus (23.1%) are the most commonly isolated species in indoor air. Aspergillus flavus (44.5%) and A. fumigatus (42.6%) were the most prevalent Aspergillus spp. outside. The most colony numbers of Aspergillus were isolated from kitchens (30.4%) and the least from bedrooms (21.1%). Aspergillus flavus was the most prevalent specie in all sampled rooms except in the kitchen where A. fumigatus was the most common. Aspergillus flavus is the most prevalent species among the Aspergillus spp. in the indoor and outdoor of a warm climate area. In these areas, A. flavus can be a major source of allergen in the air. Therefore, minimizing indoor fungal exposure could play an important role in reducing allergic symptoms in susceptible persons.  相似文献   

14.
2-Ethyl-1-hexanol is a possibly causative chemical in sick building symptoms, although 2-ethyl-1-hexanol has received little attention as a hazardous substance in studies on indoor air pollution. Airborne 2-ethyl-1-hexanol concentrations were measured from 2002 to 2004 in 99 rooms of 42 non-domestic buildings in Nagoya, Japan. The diffusive sampling method is effective for the measurement of a low level of 2-ethyl-1-hexanol in indoor air. The geometric mean (geometric standard deviation) of 2-ethyl-1-hexanol concentrations was 16.5 (5.4) microg m(-3) in indoor air and 1.9 (2.2) microg m(-3) in outdoor air. The maximum concentration of 2-ethyl-1-hexanol in indoor air and outdoor air was 2709 microg m(-3) and 12.4 microg m(-3), respectively. Fewer rooms in a small number of new buildings showed high concentrations of 2-ethyl-1-hexanol, while low concentrations were observed in many rooms of these buildings as well as the other new buildings. The room-to-room concentrations of 2-ethyl-1-hexanol in each building exhibited a wide variation. The geometric mean of the 2-ethyl-1-hexanol concentrations was significantly higher for indoor air than for outdoor air (p < 0.01). The correlation of the 2-ethyl-1-hexanol concentrations between indoor and outdoor air was not significant. Mechanical ventilation was effective in the temporary reduction of indoor 2-ethyl-1-hexanol level. These results suggest that the predominant source of 2-ethyl-1-hexanol was indoor areas.  相似文献   

15.
The exposure of paving workers to polycyclic aromatic hydrocarbons (PAH) during stone mastic asphalt (SMA) paving and remixing was evaluated. The effects on the workers' PAH exposure were also evaluated during the use of an industrial by-product, coal fly ash (CFA), instead of limestone as the filler in the SMA. The PAH exposure was measured by personal air sampling and by analysing the levels of urinary naphthols, phenanthrols and 1-hydroxypyrene (1-OHP) in the workers' pre- and post-shift urine samples. The respiratory PAH exposure of the paving workers (geometric mean (GM) 5.7 microg m(-3)) was about ten-fold that of the traffic controllers (GM 0.43 microg m(-3)). The levels of PAH metabolites were significantly higher (p < 0.05) in the post-shift urine samples than in the pre-shift urine samples, and the levels of metabolites in the post-shift urine of paving workers were significantly higher than in that of the controls (p < 0.01). Urinary 1-naphthol correlated well with the airborne concentrations of the two- to three-ring PAHs (r = 0.544, p = 0.003) and naphthalene (r = 0.655, p < 0.001), when non-smoking paving workers were tested. A good correlation was observed between urinary 1-OHP and the airborne concentrations of the four- to six-ring PAHs (r = 0.524, p = 0.003) as well as total PAHs (r = 0.575, p = 0.001). The concentrations of 1-OHP and phenanthrols in the urine of the pavers were significantly higher (p < 0.01) during remixing than during SMA paving. The CFA in the asphalt had no effect on the airborne PAH exposure or on the concentrations of the PAH metabolites in the paving workers' urine.  相似文献   

16.
In the study reported here semipermeable membrane devices (SPMDs) were used to sample 28 PAHs and 19 PCBs in the gas phase in 15 single-family houses located in an area where domestic wood burning is widespread. Eight of the households used wood burning appliances whereas the others used other systems for residential heating. Most of the studied compounds were found in the houses: the PAHs at levels that were similar to or slightly higher than published SPMD-sampled levels for background or urban sites in Sweden, and the PCBs at levels that were somewhat lower than those recently found in both indoor and outdoor urban locations. A principal component analysis revealed that wood-burning heating systems may contribute to PAHs in indoor air. The sources may be emissions indoors or penetration from outdoors. The convenience of SPMD technology facilitates its use for semi-quantitative screening and monitoring of various persistent organic compounds indoors in dwellings and working environments.  相似文献   

17.
The aims of the present study were to determine the levels of bioaerosols including airborne culturable bacteria (total suspended bacteria, Gram-positive bacteria, Staphylococcus, Staphylococcus aureus, methicillin-resistant S. aureus (MRSA), and Gram-negative bacteria), fungi, endotoxin, and viruses (influenza A, influenza B, respiratory syncytial virus types A/B, parainfluenza virus types 1/2/3, metapnemovirus, and adenovirus) and their seasonal variations in indoor air of residential apartments. Of the total suspended bacteria cultured in an indoor environment, Staphylococcus was dominant and occupied 49.0 to 61.3 % of indoor air. Among Staphylococcus, S. aureus were detected in 100 % of households' indoor air ranging from 4 to 140 CFU/m3, and 66 % of households were positive for MRSA ranging from 2 to 80 CFU/m3. Staphylococcus and S. aureus concentrations correlated with indoor temperature (adjusted β: 0.4440 and 0.403, p?<?0.0001). Among respiratory viruses, adenovirus was detected in 14 (14 %) samples and influenza A virus was detected in 3 (3 %) samples regarding the indoor air of apartments. Adenovirus concentrations were generally higher in winter (mean concentration was 2,106 copies/m3) than in spring (mean concentration was 173 copies/m3), with concentrations ranging between 12 and 560 copies/m3. Also, a strong negative correlation between adenovirus concentrations and relative humidity in indoor air was observed (r?=??0.808, p?<?0.01). Furthermore, temperature also negatively correlated with adenovirus concentrations (r?=??0.559, p?<?0.05).  相似文献   

18.
室内空气有机污染的研究现状   总被引:12,自引:1,他引:11  
主要讨论了室内空气中有机物污染的研究现状。重点介绍了室内空气中多环芳烃 (PAHs)、挥发性有机物(VOCs)、醛类化合物等的污染状况及来源。简要叙述了室内空气污染的影响因素及对人体的健康风险评价。  相似文献   

19.
Air samples were collected from 4 field sites in Europe: 2 sites from the UK, Hazelrigg (semi-rural) and Manchester (urban); 1 site from Ireland: Mace Head (rural); and 1 site from Norway: Kjeller (rural). Additionally, air samples were taken from indoor locations in Troms?, Norway. Air samples were collected using high-volume air samplers employing sampling modules containing glass-fibre filters (GFFs, particle phase), and glass columns with a polyurethane foam (PUF)-XAD-2-PUF sandwich (gaseous phase). Typical outdoor air volumes required for the determination of per- and polyfluorinated alkyl substances (PFAS) ranged from 500-1800 m3. GFFs and PUF-XAD columns were analysed separately to obtain information on phase partitioning. All air samples were analysed for volatile, neutral PFAS, with selected GFF samples halved for analysis of both neutral and airborne particle-bound ionic PFAS. Volatile PFAS were extracted from air samples by cold-column immersion with ethyl acetate, and were analysed by gas chromatography-mass spectrometry in the positive chemical ionisation mode (GC-PCI-MS). Ionic PFAS were extracted from GFFs by sonication in methanol, and were analysed by liquid chromatography-time-of-flight-mass spectrometry (LC-TOF-MS) using electrospray ionisation in the negative ion mode (ESI-). Perfluorooctanoate (PFOA) was often the predominant analyte found in the particulate phase at concentrations ranging from 1-818 pg m(-3), and 8:2 fluorotelomer alcohol (FTOH) and 6:2 FTOH were the prevailing analytes found in the gas phase, at 5-243 pg m(-3) and 5-189 pg m(-3), respectively. These three PFAS were ubiquitous in air samples. Many other PFAS, both neutral and ionic, were also present, and levels of individual analytes were in the 1-125 pg m(-3) range. Levels of some PFAS exceeded those of traditional persistent organic pollutants (POPs). In this study, the presence of 12:2 FTOH and fluorotelomer olefins (FTolefins), and ionic PFAS other than perfluorooctane sulfonate (PFOS) and PFOA, are reported in air samples for the first time. Concentrations of neutral PFAS were several orders of magnitude higher in indoor air than outdoor air, making homes a likely important diffuse source of PFAS to the atmosphere. Our repeated findings of non-volatile ionic PFAS in air samples raises the possibility that they might directly undergo significant atmospheric transport on particles away from source regions, and more atmospheric measurements of ionic PFAS are strongly recommended.  相似文献   

20.
This study was investigated the density and monthly distribution of indoor and outdoor microfungi in six different residential houses in Tekirdag City through the exposure of Petri dishes containing Rose-Bengal Streptomycin Agar media. Samples were collected in 1-month intervals over a period of 12 months between March, 2001, and February, 2002. We used 432 Petri dishes and counted a total of 4,205 microfungi colonies, 1,790 from indoor air and 2,415 from outdoor air. As a result, 42 species belonging to 12 genera were identified. The most frequent fungal genera were Penicillium (28.61%), Cladosporium (16.08%) and Alternaria (15.98%). While Penicillium (40.61%) and Cladosporium (15.92%) were the dominant genera of indoor air, Alternaria (20.62%) and Penicillium (19.71%) were isolated most frequently from outdoor air (Table 3). Alternaria citri (10.15%) and Penicillium brevicompactum (10.15%) were found to be the most frequent among the 42 identified species. While P. brevicompactum (19.55%) and Aspergillus niger (6.37%) were the most frequent indoor species, A. citri (13.37%) and Cladosporium cladosporioides (8.20%) were the most frequent outdoor species. Linear Regression Analysis was applied to determine whether or not there was a relationship between the number of colonies of isolated fungal genera and meteorological factors during the research period. Correlations between the presence of Aspergillus and temperature, relative humidity, duration of sunny periods and agents of air pollution such as SO(2) and PM were statistically significant. No significant correlations, however, were found between other fungal genera and environmental variables.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号