首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fused-silica-lined (FSL) canisters and SUMMA polished (SUMMA) canisters were compared for the recoveries and the stabilities of 58 volatile organic compounds (VOCs) at low ppbv (volume/volume) levels under various humidified conditions using a three-stage preconcentration method followed by GC-MS analysis. The target VOCs included non-polar VOCs (e.g. halogenated hydrocarbons and aromatic hydrocarbons) and polar VOCs (e.g. alcohols, ketones, esters, ethers, nitriles and thiols). The three-stage preconcentration method was initially optimized for simultaneous analysis of non-polar and polar VOCs because determination of canister stability is dependent on the accuracy of analytical measurements. The method showed good linearity over the concentration range from 1 to 25 ppbv for all target analytes, and the correlation coefficients were higher than 0.9974. The method detection limits ranged from 0.023 to 0.39 ppbv. The test mixtures loaded in both type of canisters (n = 3) had concentrations of 1.7-2.5 ppbv per compound at ambient pressure under various humidified conditions (%RH = 1.6, 8.0, 27, 39, 53 and >99% with excess water present). All canister samples were initially analyzed on day 0 (after 6-12 h). The effect of competitive adsorption of water vapor and polar VOCs on active sites of interior surface was remarkably observed for SUMMA canisters. Polar VOCs had a greater requirement for water vapor to be present. The RH percentages that ensured good recovery on day 0 were RH > 8% for non-polar VOCs and RH > 27% for polar VOCs (except alcohols under the condition of RH > 99%). All thiols were not recovered from SUMMA canisters under all conditions. FSL canisters showed good recoveries of more than 86% for all VOCs under all conditions on day 0 (except alcohols under the condition of RH > 99%). The recoveries of alcohols in both canisters under the condition of RH > 99% displayed relatively low recoveries in the range 25-76% because of the partitioning effect into condensed water. The canister samples under the conditions of RH 8.0, 27, 53 and > 99% were analyzed for the stability test on days 3, 7, 14 and 28 after loading. All non-polar VOCs were reasonably stable in the FSL canisters under all examined conditions over 28 days. However, several polar VOCs that have relatively lower vapor pressure, e.g. MIBK, butyl acetate and alcohols except ethanol, showed unstable characteristics under relatively dry conditions (RH 8 and 27%) during 28 days. RH > 53% was needed to ensure good stabilities of all analytes except thiols with the recoveries of > 80% over 28 days for both canisters. Although the FSL canister showed good recoveries of more than 86% for thiols on day 0, drastic degradations were observed after day 3 and they were not detected after day 14.  相似文献   

2.
真空罐/气相色谱-质谱法是我国目前用于环境空气中挥发性有机物(VOCs)监测的主要方法。对该方法的采样前及采样环节的技术细节(包括流量控制器和过滤器的校准检查,采样罐的性能检查,样品的采集、运输及保存),以及实验室分析环节的技术细节(包括色谱柱的选择,内标物的选择,湿度及气体稀释仪对分析结果的影响,标准曲线绘制方式和系统性能优劣的判断)进行讨论和分析。并针对以上技术细节提出解决方案和注意事项,以期为分析人员提供技术参考。  相似文献   

3.
将挥发性有机污染物在线监测系统与实验室内SUMMA罐采样气质联用法(GC-MS)的挥发性有机物分析进行了标准气体和实际空气样品的分析比对,并对偏差原因作分析,提出在线监测系统的维护建议。结果表明,挥发性有机物在线监测系统的监测结果与实验室方法有一定的可比性,可用于大气中挥发性有机污染物的在线监测。  相似文献   

4.
Despite the frequent occurrence of vehicle fires, very few studies investigating firefighters' potential inhalation exposures during vehicle fire suppression have been conducted. In this paper, we present an assessment of firefighters' health risk from vehicle fire suppression that accounts for the mixture of gases and vapors likely to be found in these fires. Summa canisters were used to collect emissions from the engine and cabin fires of a single vehicle and were analyzed for 75 volatile organic compounds (VOCs). Firefighters' breathing zone concentrations (BZCs) of aromatic hydrocarbons, aldehydes, isocyanates, and carbon monoxide were measured during the suppression of three vehicle fires. The Summa canister and BZC data were used to develop a simple model for predicting BZCs for the compounds that were not measured in the firefighters' breathing zones. Hazard quotients (HQs) were calculated by dividing the predicted and measured BZCs by the most conservative short-term exposure limits (STELs) or ceiling limits. Hazard indices (HIs) were determined by adding HQs for compounds grouped by the target organ for acute health effects. Any HIs above unity represented unacceptable risks. According to this mixture analysis, the estimated 95(th) percentile of the exposure distribution for the study population represents ≥ 9.2 times the acceptable level of risk to the respiratory tract and eyes. Furthermore, chemicals known or reasonably anticipated to be human carcinogens contributed to > 45% of these HIs. While STELs are not usually based on carcinogenicity, maintaining exposures below STELs may protect individuals from the biological stress that could result from short-term exposures to carcinogens over time. Although vehicle fires are suppressed quickly (<10 min), this assessment suggests that firefighters have the potential to be overexposed to acute toxins during vehicle fire suppression and should therefore wear self-contained breathing apparatus at all times during vehicle fire response.  相似文献   

5.
During a monitoring campaign concentrations of volatile organic compounds (VOCs) were measured in indoor air of 79 dwellings where occupants had not complained about health problems or unpleasant odour. Parameters monitored were the individual concentration of 68 VOCs and the total concentration of all VOCs inside the room. VOCs adsorbed by Tenax TA were then analysed by means of thermal desorption, gas chromatography and mass spectrometry. The analytical procedure and quantification was done according to the recommendation of the ECA-IAQ Working Group 13 which gave a definition of the total volatile organic compound (TVOC) concentration. Using this recommendation TVOC-concentrations ranged between 33 and 1600 microg m(-3) with a median of 289 microg m(-3). Compounds found in every sample and with the highest concentrations were 2-propanol, alpha-pinene and toluene. Save for a few samples, all concentrations measured have been a factor 2 to 10 lower, compared to data from similar studies. Only a few terpenes and aldehydes were found exceeding published reference data or odour threshold concentrations. However, it has been found that sampling and analysing methods do have a considerable impact on the results, making direct comparisons of studies somewhat questionable. 47% of all samples revealed concentrations exceeding the threshold value of 300 microg TVOC m(-3) set by the German Federal Environmental Agency as a target for indoor air quality. Using the TVOC concentration as defined in the ECA-IAQ methodology is instrumental in assessing exposure to VOCs and identifying sources of VOCs. The background concentrations determined in this study can be used to discuss and interpret target values for individual and total volatile organic compounds in indoor air.  相似文献   

6.
基于在线气相色谱-氢火焰离子检测/质谱(GC-FID/MS)方法,在线测量116种大气挥发性有机物的性能指标(线性关系、检出限、精密度、正确度、期间正确度和期间精密度).基于在线监测系统连续7d的实际运行情况,定量评估116种有机物在实际长期运行中测量的准确性和可靠性.结果 表明,116种组分中,109种组分的线性相关...  相似文献   

7.
Healthcare settings present a challenging environment for assessing low-level concentrations of specific volatile organic compounds (VOCs) in the presence of high background concentrations of alcohol from the use of hand sanitizers and surface disinfectants. The purposes of this laboratory-based project were to develop and validate a sampling and analysis methodology for quantifying low-level VOC concentrations as well as high-level alcohol concentrations found together in healthcare settings. Sampling was conducted using evacuated canisters lined with fused silica. Gas chromatography/mass spectrometry analysis was performed using preconcentration (for ppb levels) and loop injection (for ppm levels). For a select list of 14 VOCs, bias, precision, and accuracy of both the preconcentration and loop injection methods were evaluated, as was analyte stability in evacuated canisters over 30 days. Using the preconcentration (ppb-level) method, all validation criteria were met for 13 of the 14 target analytes-ethanol, acetone, methylene chloride, hexane, chloroform, benzene, methyl methacrylate, toluene, ethylbenzene, m,p-xylene, o-xylene, alpha-pinene, and limonene. Using the loop injection (ppm-level) method, all validation criteria were met for each analyte. At ppm levels, alpha-pinene and limonene remained stable over 21 days, while the rest of the analytes were stable for 30 days. All analytes remained stable over 30 days at ppb levels. This sampling and analysis approach is a viable (i.e., accurate and stable) methodology that will enable development of VOC profiles for mixed exposures experienced by healthcare workers.  相似文献   

8.
Ambient air spiked with 1-10 ppbv concentrations of 41 toxic volatile organic compounds (VOCs) listed in US Environmental Protection Agency (EPA) Compendium Method TO-14A was monitored using solid sorbents for sample collection and a Varian Saturn 2000 ion trap mass spectrometer for analysis. The adsorbent was a combination of graphitic carbon and a Carboxen-type carbon molecular sieve. The method detection limits (MDLs) for 11 samples were typically 0.5 parts per billion by volume (ppbv) and lower except for bromomethane and chloromethane, both of which exhibited breakthrough. Thirty-day sample storage on the sorbents resulted in less than a 20% change for most compounds, and water management was required for humid samples to avoid major anomalous decreases in response during analyses. The adsorbent-based system, a system using canister-based monitoring, and a semi-continuous automated GC/MS (autoGC) monitoring system with a Tenax GR/Carbotrap B/Carbosieve S-III adsorbent preconcentrator were compared using spiked ozone concentrations as a variable. In this comparison, the target compounds included a number of n-aldehydes as well as those listed in TO-14A. The effects of ozone on the TO-14A compounds were relatively minor with the exception of negative artifacts noted for styrene and 1,1,2,2-tetrachloroethane. However, a small, systematic decrease in response was evident for a number of aromatic VOCs and 1,1,2,2-tetrachloroethane when ozone was increased from 50 to 300 ppbv. Method averages for multiple runs under the same conditions were typically within +0.25 ppbv of their mean for most compounds. For n-aldehydes, strong positive artifacts using the autoGC preconcentrator and strong negative artifacts for the canister-based and carbon sorbent approaches caused major disagreement among methods. These artifacts were mostly eliminated by using MnO2 ozone scrubbers, although loss of the n-aldehydes for all methods occurred after a single sample collection of 1 h duration, apparently due to the interaction of the n-aldehydes and products of the O3, MnO2 reaction on the scrubber.  相似文献   

9.
空气中挥发性有机物污染状况及健康风险评价   总被引:11,自引:0,他引:11  
为了了解南京某县空气中挥发性有机污染物(VOCs)的污染状况,采用苏码罐采样-气相色谱-质谱法分析了该县不同功能区空气中的VOCs,探讨了其可能来源并采用国际公认的评价模型,对空气中的VOCs进行了健康风险评价。  相似文献   

10.
Solid-phase microextraction (SPME) was studied for the measurement of volatile organic compounds (VOCs) in indoor air. An adsorptive PDMS/Carboxen fibre was used and an analytical methodology was developed in order to overcome competitive adsorption. Kinetics and adsorption isotherms were investigated for different sample volumes and model compounds. In order to evaluate competitive adsorption on the fibre, these compounds were studied alone and in mixture. From the results obtained, the operating conditions allowing co-adsorption of the target compounds were determined: the air sample is enclosed in a 250 mL glass bulb where the SPME fibre is exposed until adsorption equilibrium. This procedure was combined with GC/MS analysis for the identification and quantification of VOCs in indoor air. The performances were determined by using a standard gas containing 10 VOCs representative of indoor environments (acetaldehyde, acetone, BTX, alpha-pinene, trichloroethylene, alkanes). The detection limits were determined in single ion monitoring mode and for a signal to noise ratio of 3. Except acetaldehyde (6 microg m(-3)), they are all below 0.5 microg m(-3). Calibration curves are linear up to 10 micromol m(-3) for all the compounds with good correlation coefficients (above 0.99). The reproducibility ranges from 6 to 12% according to the compound. The methodology was then applied to the comparison of the VOCs content in classrooms of two different schools.  相似文献   

11.
建立了使用活性炭管采集臭气中的挥发性有机物,经二硫化碳解吸,用GC-MS仪Scan扫描方式确定挥发性有机物的组分后优化GC-MS条件定性定量分析上海化学工业区污水处理厂臭气中主要挥发性有机物的方法。结果表明,从臭气中检测出11种VOCs,线性相关系数R2均大于0.99,相对标准偏差为3.0%~4.7%,除了苯乙烯、α-甲基苯乙烯和4-甲基苯乙烯的解吸效率依次分别为72%、74%和66%,其他挥发性有机物的解吸效率均为91%~100%。本方法操作简便,能够有效分离和准确测定臭气中挥发性有机物,具有较低的检出限和较好的精确度,适合臭气中挥发性有机物的检测分析,可为臭气控制提供可靠的数据。  相似文献   

12.
High resolution gas chromatography - mass spectrometry (GC-MS) has been widely used in the field of environmental sample analysis for volatile organic compounds (VOCs) (Gryder-Boutet, et al., 1988). Such a technique was applied to the analysis of VOCs at a local municipal wastewater treatment plant. The combination of purge and trap sample preparation and thermal desorption with cryofocusing technology, allows for the detection of a wide range of volatiles in wastewater and sludge samples. Results show that a large variety of organics present in samples are aliphatic and aromatic hydrocarbons. Their concentrations are in part per billion levels between 10 to 150 g/L. Others identified using this method are chlorinated hydrocarbons, sulfides and organic acids. By comparing the chromatograms of different wastewater and sludge samples collected from various treatment process units, it can be seen that most volatiles were removed or degraded after the aeration or digestion process. Information that provides an insight to the measurement of organic compounds in sludges is also discussed in this paper.  相似文献   

13.
A canister-based 1 week sampling method using a mechanical flow controller and a 6 L fused-silica-lined canister was evaluated for the long-term measurement of 47 VOCs in ambient air at pptv (volume/volume) to ppbv levels by use of a three-stage preconcentation method followed by GC-MS analysis. The GC conditions were initially optimized for complete separations of several pptv-level VOCs (e.g. vinyl chloride, 1,3-butadiene, acrylonitrile, 1,2-dichloroethane and chloroform) in ambient air because the selected ions are easily interfered with by coexisting C4-, C5-hydrocarbons and analytes presented at ppbv levels. Thirty-four VOCs determined by the 1 week and 24 h sampling method in December 16-22 (2002) had concentrations of 6.0-15000 pptv per compound. Concentrations of 28 VOCs (including polar VOCs (e.g. methyl isobutyl ketone and butyl acetate)) obtained by the method were approximately equal to the mean values calculated from 24 h sampling (< +/- 10% deviation). Six VOCs that had low concentrations of 6.0-43 pptv showed more than +/- 10% deviation. Thirteen VOCs were not detected during the entire sampling period. The effect of relative humidity or ozone for the specific VOCs (e.g. MIBK, butyl acetate, vinyl chloride, 1,3-butadiene and styrene) was negligible.  相似文献   

14.
采用大气浓缩仪-气相色谱法测定超低沸点挥发性有机物乙烷、乙烯、丙烷、丙烯、乙炔,选用PLOT-Q柱分析,控制真空罐内相对湿度约50%,通过优化测定条件使方法线性良好,5种低沸点化合物的检出限为0.08 nmol/mol~0.2 nmol/mol,样品保存时间不超过10 d。用该方法测定某地区环境空气中VOCs,结果检出率均为100%。  相似文献   

15.
Analytical results obtained by thermal desorption GC/MS for 24 h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive sampling tubes and one passivated canister. A total of eight multiple-component sampling events took place at fixed positions inside and outside three private homes. Subsequently, a known amount of sample air was transferred from the canister to an adsorbent tube for analysis by thermal desorption GC/MS. Results for the 11 most prevalent compounds--Freon 11, 1,3-butadiene, benzene, toluene, tetrachloroethene, ethylbenzene, m,p-xylene, o-xylene, 4-ethyltoluene, 1,3,5-trimethylbenzene, and p-dichlorobenzene--show that the ratio of average study values (diffusive sampling to active sampling) is 0.92 with 0.70 and 1.14 extreme ratios. Absolute percent difference for duplicate samples using diffusive sampling was <10% for the four most prevalent compounds. Agreement between the two sampling approaches indicates that the prediction of approximately constant diffusive sampling rates based on previous laboratory studies is valid under the field conditions.  相似文献   

16.
456 water samples collected from 152 water sources in 2006 were analyzed for 21 volatile organic compounds (VOCs). Concentrations of 21 VOCs ranged from below method detection limits of the laboratory to 7.65 ??g/L (toluene), but seldom exceeded the concentration limits set in the National Drinking Water Quality Standards (GB5749-2006) or the National Environmental Quality Standards for Surface Water (GB3838-2002) of China. Of the 21 individual VOCs analyzed, 11 VOCs were detected in at least one sample at or above 1.0 ??g/L; 6.6% of the water samples had a detection of at least one VOC at or above 1.0 ??g/L, and 2.6% had a detection of at least two VOCs at or above 1.0 ??g/L. Based on the statistical data of detection frequencies above the method detection limits, 75% of the samples detected at least one VOC, and 65% of the samples detected at least two VOCs. Chloroform, toluene, and 1,2-dichloroethene were the three most frequently detected VOCs, with detection frequencies of 76.97%, 68.42%, and 44.08%, respectively. Volatile halogenated hydrocarbons and gasoline components were the two most frequently detected VOC groups.  相似文献   

17.
A field experiment for the comparison of the efficiency of canisters and adsorption multibed tubes for sampling atmospheric highly volatile hydrocarbons at ppbv levels is described. The canister was passivated by the Summa process and the adsorption tubes were filled with Carbotrap C, Carbotrap B and Carbosieve S-III. The sampling with the adsorption tubes was performed at ambient temperature and at -10°C. The highest concentrations were generally obtained with canisters but these results are very similar to those obtained with refrigerated multibed adsorption tubes. Both methods appear to be equivalent for most of the highly volatile hydrocarbons encountered in moderately polluted urban areas. In contrast, sampling with ambient temperature tubes provides lower concentrations. This study has also shown that K2CO3 drying efficiently removes humidity from air samples allowing the obtention of reliable concentration data on highly volatile hydrocarbons at ppbv levels. These drying tubes can easily be re-conditioned and tested for blanks and memory effects, which greatly facilitates the control of external contamination and sample cross-contamination.  相似文献   

18.
19.
中国沿海三省主要饮用水源有机物监测   总被引:3,自引:2,他引:1  
采用固相萃取、吹扫捕集和气相色谱-质谱联用仪(GC-MS)对江苏、浙江、山东省的21个主要地表饮用水源、126份水样中的25种VOCs、38种SVOCs进行定量检测。结果有19种VOCs、10种SVOCs至少在一个水源地多次被检出,其中挥发性氯代烃、苯系物、氯代苯类、酚类、硝基苯类、酞酸酯类、农药为中国或美国环境保护局提出的"水中优先控制污染物",最高检出量为27.79μg/L。三省主要地表水受到有机物轻度污染,水体中VOCs、SVOCs含量尚未超过《地表水环境质量标准》(GB 3838-2002)和《生活饮用水卫生标准》(GB 5749-2006)限值,工业废水排放及农田雨水径流是地表水有机物的重要来源。  相似文献   

20.
以便携式GC-MS测定气体样品中6种典型挥发性有机物(VOCs)组分(苯、1,1,2-三氯乙烷、四氯乙烯、乙苯、间二甲苯和1,3,5-三甲基苯)为例,应用不确定度理论,从检测过程和计算方法的角度分析了影响测量不确定度的各种因素:标准气体定值、标准气体稀释、工作曲线的非线性及重复性测定。对各测量不确定度分量进行计算和评定,同时采用稳健统计方法对测定结果进行准确度评价。结果表明:采用便携式GC-MS测定气体样品中VOCs不确定度的主要影响因素是标准气体定值和工作曲线的非线性,其次是重复性测定,标准气体稀释引入的不确定度较小。当VOCs组分含量为200 nmol/mol浓度水平时,测量扩展不确定度为14~17 nmol/mol,测量相对扩展不确定度为7.1%~9.2%(k=2,置信水平为95%),相对误差为1.5%~4.0%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号