首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 173 毫秒
1.
Abstract

Odorous gases associated with livestock operations are complex mixtures of hundreds if not thousands of compounds. Research is needed to know how best to sample and analyze these compounds. The main objective of this research was to compare recoveries of a standard gas mixture of 11 odorous compounds from the Carboxen/PDMS 75–μm solid–phase microextraction fibers, polyvinyl fluo–ride (PVF; Tedlar), fluorinated ethylene propylene copolymer (FEP; Teflon), foil, and polyethylene terephthalate (PET; Melinex) air sampling bags, sorbent 2,b–diphenylene–oxide polymer resin (Tenax TA) tubes, and standard 6–L Stabilizer sampling canisters after sample storage for 0.5, 24, and 120 (for sorbent tubes only) hrs at room temperature. The standard gas mixture consisted of 7 volatile fatty acids (VFAs) from acetic to hexanoic, and 4 semivolatile organic compounds including p–cresol, indole, 4–ethylphenol, and 2'–aminoacetophenone with concentrations ranging from 5.1 ppb for indole to 1270 ppb for acetic acid. On average, SPME had the highest mean recovery for all 11 gases of 106.2%, and 98.3% for 0.5– and 24–hr sample storage time, respectively. This was followed by the Tenax TA sorbent tubes (94.8% and 88.3%) for 24 and 120 hr, respectively; PET bags (71.7% and 47.2%), FEP bags (75.4% and 39.4%), commercial Tedlar bags (67.6% and 22.7%), in–house–made Tedlar bags (47.3% and 37.4%), foil bags (16.4% and 4.3%), and canisters (4.2% and 0.5%), for 0.5 and 24 hr, respectively. VFAs had higher recoveries than semivolatile organic compounds for all of the bags and canisters. New FEP bags and new foil bags had the lowest and the highest amounts of chemical impurities, respectively. New commercial Tedlar bags had measurable concentrations of N,N–dimethyl acetamide and phenol. Foil bags had measurable concentrations of acetic, propionic, butyric, valeric, and hexanoic acids.  相似文献   

2.
Regulation to control air emissions of toxic organic compounds require the collection and analysis of effluent gas from low level sources such as hazardous waste incinerators. The standard SW- 846 Method specifies the use of Tenax and Tenax/charcoal adsorbent traps for collection of volatile organics from incinerators. This study evaluates passivated stainless steel canisters as an alternative to adsorbent traps to eliminate some of the problems associated with adsorbent sampling. Initially the stability of 18 nonpolar, volatile organic compounds was determined in Summa-treated stainless steel canisters with greater than 100 ppmv HCI and saturated with water vapor. All 18 components were stable for a twoweek period; however, an Interference caused a 10-fold increase In the FID response of trlchloroethylene, toluene, and chlorobenzene. No Interference of the ECD response was found for any of the 11 compounds detected with the ECD including trlchloroethylene. A pilot scale incinerator was sampled using canisters, and the destruction efficiency of 1,1,1-trichloroethane was determined at a concentration of less than 0.5 ppbv while determining 1,1-dichloroethylene, the major product of Incomplete combustion, at a concentration of 8000 ppbv from the same sample.  相似文献   

3.
The maximum amounts of phenanthrene that can be adsorbed in both the slowly desorbing domain and the very slowly desorbing domain of two sediments were determined. To this end, native compounds were removed by mild solvent extraction, heating, or extraction by Tenax. Maximum capacities for adsorption of phenanthrene in the very slowly desorbing domain after removal of native compounds by heating the sediments at 300 degrees C for 24 h were comparable to those after extraction with Tenax at 60 degrees C for 13 days. Mild solvent extraction resulted in lower capacities due to incomplete removal of native compounds. For the slowly desorbing domain, heating the sediment or performing mild solvent resulted in maximum capacities for adsorption exceeding those obtained after non-invasive extraction with Tenax. That was taken to indicate alterations of the sorbent by the solvent or high temperature resulting in an overestimation of the maximum capacities for adsorption. It is concluded that for the determination of maximum capacities of adsorption in the very slowly desorbing domain, removal of native compounds by heating at 300 degrees C for 24 h is reliable and practical. However, for the determination of maximum adsorption capacities of the slowly desorbing domain, native compounds have to be removed by a non-invasive technique such as extraction by Tenax.  相似文献   

4.
Volatile organic compounds (VOCs) emitted from poultry production are leading source of air quality problems. However, little is known about the speciation and levels of VOCs from poultry production. The objective of this study was the speciation of VOCs from a poultry facility using evacuated canisters and sorbent tubes. Samples were taken during active poultry production cycle and between production cycles. Levels of VOCs were highest in areas with birds and the compounds in those areas had a higher percentage of polar compounds (89%) compared to aliphatic hydrocarbons (2.2%). In areas without birds, levels of VOCs were 1/3 those with birds present and compounds had a higher total percentage of aliphatic hydrocarbons (25%). Of the VOCs quantified in this study, no single sampling method was capable of quantifying more than 55% of compounds and in several sections of the building each sampling method quantified less than 50% of the quantifiable VOCs. Key classes of chemicals quantified using evacuated canisters included both alcohols and ketones, while sorbent tube samples included volatile fatty acids and ketones. The top five compounds made up close to 70% of VOCs and included: 1) acetic acid (830.1 μg m?3); 2) 2,3-butanedione (680.6 μg m?3); 3) methanol (195.8 μg m?3); 4) acetone (104.6 μg m?3); and 5) ethanol (101.9 μg m?3). Location variations for top five compounds averaged 49.5% in each section of the building and averaged 87% for the entire building.  相似文献   

5.
Four popular thermally desorbable adsorbents used for air sampling (Tenax TA, Tenax GR, Carbopack B, and Carbopack X) are examined for the potential to form artifacts with ozone (O3) at environmental concentrations. The performance of these adsorbents for the ketone and aldehyde species identified as O3-adsorbent artifacts was also characterized, including recovery, linearity, and method detection limits (MDLs). Using gas chromatography/mass spectrometry, 13 different artifacts were identified and confirmed for both Tenax TA and Tenax GR, 9 for Carbopack B, but none for Carbopack X. Several O3 artifacts not reported previously were identified, including: pentanal, 3-hexanone, 2-hexanone, hexanal, 3-heptanone, and heptanal with Tenax TA; pentanal, 3-hexanone, 2-hexanone, hexanal, and 3-heptanone on Tenax GR; and 1-octene and 1-nonene with Carbopack B. Levels of straight-chain aldehyde artifacts rapidly diminished after a few cycles of adsorbent conditioning/O3 exposure, and concentrations could be predicted using a first-order model. Phenyl-substituted carbonyl artifacts (benzaldehyde and acetophenone) persisted on Tenax TA and GR even after 10 O3 exposure-conditioning cycles. O3 breakthrough through the adsorbent bed was most rapid in adsorbents that yielded the highest levels of artifacts. Overall, artifact composition and concentration are shown to depend on O3 concentration and dose, conditioning method, and adsorbent type and age. Calibrations showed good linearity, and most compounds had reasonable recoveries, for example, 90 +/- 15% for Tenax TA, 97 +/- 23% for Tenax GR, 101 +/- 24% for Carbopack B, and 79 +/- 25% (91 +/- 9% for n-aldehydes) for Carbopack X. Benzeneacetaldehyde recovery was notably poorer (22-63% across the four adsorbents). MDLs for several compounds were relatively high, up to 5 ng. By accounting for both artifact formation and method performance, this work helps to identify which carbonyl compounds can be measured using thermally desorbable adsorbents and which may be prone to bias because of the formation of O3-adsorbent artifacts.  相似文献   

6.
Font R  Aracil I  Fullana A  Conesa JA 《Chemosphere》2004,57(7):615-627
The evolution of semivolatile and volatile compounds in the combustion of polyethylene (PE) was studied at different operating conditions in a horizontal quartz reactor. Four combustion runs at 500 and 850 degrees C with two different sample mass/air flow ratios and two pyrolytic runs at the same temperatures were carried out. Thermal behavior of different compounds was analyzed and the data obtained were compared with those of literature. It was observed that alpha,omega-olefins, alpha-olefins and n-paraffins were formed from the pyrolytic decomposition at low temperatures. On the other hand, oxygenated compounds such as aldehydes were also formed in the presence of oxygen. High yields were obtained of carbon oxides and light hydrocarbons, too. At high temperatures, the formation of polycyclic aromatic hydrocarbons (PAHs) took place. These compounds are harmful and their presence in the combustion processes is related with the evolution of pyrolytic puffs inside the combustion chamber with a poor mixture of semivolatile compounds evolved with oxygen. Altogether, the yields of more than 200 compounds were determined. The collection of the semivolatile compounds was carried out with XAD-2 adsorbent and were analyzed by GC-MS, whereas volatile compounds and gases were collected in a Tedlar bag and analyzed by GC with thermal conductivity and flame ionization detectors.  相似文献   

7.
Abstract

Four popular thermally desorbable adsorbents used for air sampling (Tenax TA, Tenax GR, Carbopack B, and Carbopack X) are examined for the potential to form artifacts with ozone (O3) at environmental concentrations. The performance of these adsorbents for the ketone and alde-hyde species identified as O3-adsorbent artifacts was also characterized, including recovery, linearity, and method detection limits (MDLs). Using gas chromatography/mass spectrometry, 13 different artifacts were identified and confirmed for both Tenax TA and Tenax GR, 9 for Carbopack B, but none for Carbopack X. Several O3 artifacts not reported previously were identified, including: pentanal, 3-hexanone, 2-hexanone, hexanal, 3-heptanone, and heptanal with Tenax TA; pentanal, 3-hexanone, 2-hexanone, hexanal, and 3-heptanone on Tenax GR; and 1-octene and 1-nonene with Carbopack B. Levels of straight-chain aldehyde artifacts rapidly diminished after a few cycles of adsorbent conditioning/O3 exposure, and concentrations could be predicted using a first-order model. Phenyl-substituted carbonyl artifacts (benzalde-hyde and acetophenone) persisted on Tenax TA and GR even after 10 O3 exposure-conditioning cycles. O3 breakthrough through the adsorbent bed was most rapid in adsorbents that yielded the highest levels of artifacts. Overall, artifact composition and concentration are shown to depend on O3 concentration and dose, conditioning method, and adsorbent type and age. Calibrations showed good linearity, and most compounds had reasonable recoveries, for example, 90 ±15% for Tenax TA, 97 ±23% for Tenax GR, 101 ±24% for Carbopack B, and 79 ±25% (91 ±9% for n-aldehydes) for Carbopack X. Benzeneacetaldehyde recovery was notably poorer (22–63% across the four adsorbents). MDLs for several compounds were relatively high, up to 5 ng. By accounting for both artifact formation and method performance, this work helps to identify which carbonyl compounds can be measured using thermally desorbable adsorbents and which may be prone to bias because of the formation of O3- adsorbent artifacts.  相似文献   

8.
We describe an experimental system and techniques for sampling and analyzing biogenic emissions of volatile organic compounds (VOC). The system uses a Teflon chamber to enclose a single branch of a tree. Temperature, photosynthetic active radiation (PAR), relative humidity and carbon dioxide concentration are continuously monitored with a time resolution of five minutes. VOCs are sampled on tubes containing solid adsorbents (Tenax TA and Carbotrap) with a time resolution of 1 h. Composition and concentration of VOC emissions are measured with a gas chromatographic system equipped with a flame ionization detector (FID) for quantitative and a mass spectrometer (MS) for qualitative analysis. To calibrate the system, a diffusion source was built to produce standard mixtures of up to 36 different compounds with mixing ratios at low concentrations and high accuracy. The diffusion rates were monitored over 17 months and showed variations between 0.2 and 7.6% for monoterpenes (expect for α-phellandrene, α-terpinene and γ-terpinene) and between 10.6 and 22.6% for sesquiterpenes. FID response factors calculated from calibration measurements were corrected using correction factors based on the effective carbon number concept. The individual response factors of 23 compounds were combined to a mean response factor (RFm) with a value of 23,100 μV s ng−1 and a standard deviation of 9%. The system described here was used to measure VOC emission rates of Scots pine (Pinus sylvestris) in 1998 and 1999.  相似文献   

9.
The National Institute for Occupational Safety and Health (NIOSH) research on direct-reading instruments (DRIs) needed an instantaneous sampling method to provide independent confirmation of the concentrations of chemical warfare agent (CWA) simulants. It was determined that evacuated canisters would be the method of choice. There is no method specifically validated for volatile organic compounds (VOCs) in the NIOSH Manual of Analytical Methods. The purpose of this study was to validate an evacuated canister method for sampling seven specific VOCs that can be used as a simulant for CWA agents (cyclohexane) or influence the DRI measurement of CWA agents (acetone, chloroform, methylene chloride, methyl ethyl ketone, hexane, and carbon tetrachloride [CCl4]). The method used 6-L evacuated stainless-steel fused silica-lined canisters to sample the atmosphere containing VOCs. The contents of the canisters were then introduced into an autosampler/preconcentrator using a microscale purge and trap (MPT) method. The MPT method trapped and concentrated the VOCs in the air sample and removed most of the carbon dioxide and water vapor. After preconcentration, the samples were analyzed using a gas chromatograph with a mass selective detector. The method was tested, evaluated, and validated using the NIOSH recommended guidelines. The evaluation consisted of determining the optimum concentration range for the method; the sample stability over 30 days; and the accuracy, precision, and bias of the method. This method meets the NIOSH guidelines for six of the seven compounds (excluding acetone) tested in the range of 2.3-50 parts per billion (ppb), making it suitable for sampling of these VOCs at the ppb level.  相似文献   

10.
The use of sorbents has been proposed to remove volatile organic compounds (VOCs) present in ambient air at concentrations in the parts-per-billion (ppb) range, which is typical of indoor air quality applications. Sorbent materials, such as granular activated carbon and molecular sieves, are used to remove VOCs from gas streams in industrial applications, where VOC concentrations are typically in the parts-per-million range. A method for evaluating the VOC removal performance of sorbent materials using toluene concentrations in the ppb range is described. Breakthrough times for toluene at concentrations from 2 to 7500 ppb are presented for a hydrophobic molecular sieve at 25%) relative humidity. By increasing the ratio of challenge gas flow rate to the mass of the sorbent bed and decreasing both the mass of sorbent in the bed and the sorbent particle size, this method reduces the required experimental times by a factor of up to several hundred compared with the proposed American Society of Heating, Refrigerating, and Air-Conditioning Engineers method, ASHRAE 145P, making sorbent performance evaluation for ppb-range VOC removal more convenient. The method can be applied to screen sorbent materials for application in the removal of VOCs from indoor air.  相似文献   

11.
ABSTRACT

During a preliminary field campaign of volatile organic compound (VOC) measurements carried out in an urban area, two complementary analysis techniques were applied to establish the technical and scientific bases for a strategy to monitor and control VOCs and photochemical oxidants in the Autonomous Community of the Basque Country. Integrated sampling was conducted using Tenax sorbent tubes and laboratory analysis by gas chromatography, and grab sampling and in situ analysis also were conducted using a portable gas chromatograph. With the first technique, monocyclic aromatic hydrocarbons appeared as the compounds with the higher mean concentrations. The second technique allowed the systematic analysis of eight chlorinated and aromatic hydrocarbons. Results of comparing both techniques, as well as the additional information obtained with the second technique, are included.  相似文献   

12.
Abstract

The use of sorbents has been proposed to remove volatile organic compounds (VOCs) present in ambient air at concentrations in the parts-per-billion (ppb) range, which is typical of indoor air quality applications. Sorbent materials, such as granular activated carbon and molecular sieves, are used to remove VOCs from gas streams in industrial applications, where VOC concentrations are typically in the parts-per-million range. A method for evaluating the VOC removal performance of sorbent materials using toluene concentrations in the ppb range is described. Breakthrough times for toluene at concentrations from 2 to 7500 ppb are presented for a hydrophobic molecular sieve at 25% relative humidity. By increasing the ratio of challenge gas flow rate to the mass of the sorbent bed and decreasing both the mass of sorbent in the bed and the sorbent particle size, this method reduces the required experimental times by a factor of up to several hundred compared with the proposed American Society of Heating, Refrigerating, and Air-Conditioning Engineers method, ASHRAE 145P, making sorbent performance evaluation for ppb-range VOC removal more convenient. The method can be applied to screen sorbent materials for application in the removal of VOCs from indoor air.  相似文献   

13.
Select volatile organic compounds (VOCs) in ambient air were measured at four fenceline sites at a petroleum refinery in Whiting, IN, using modified EPA Method 325 A/B with passive tubes and EPA Compendium Method TO-15 with canister samplers. One-week, time-integrated samplers were deployed for 8 weeks with tubes and canister samplers deployed in duplicate. Good precision was obtained from the duplicate tubes (<7%) and duplicate canisters (≤10%) for BTEX, perchloroethylene, and styrene. The tubes yielded statistically significantly higher concentrations than canisters for benzene, toluene, ethylbenzene, and m,p-xylene. However, all differences were estimated to be <0.1 ppbv. No concentration differences among the four Whiting sites were found for any of the VOCs.

Implications: Recently enacted EPA Methods 325A/B use passive-diffusive tube samplers to measure benzene at refinery fenceline locations. This pilot study presents VOC data applying a modified version of EPA Method 325 A/B and its comparison to EPA Compendium Method TO-15 canister samplers at four refinery fenceline sites. The findings from this study provide additional confidence in application of the tube method at refineries to ascertain VOC source influence since tube and canister samplers were comparable and good precision was obtained from duplicate sampling for both methods. No overall difference in these reported VOC concentrations was found between Whiting sites for tubes or canisters.  相似文献   


14.
Recent studies suggest that dairy operations may be a major source of non-methane volatile organic compounds in dairy-intensive regions such as Central California, with short chain carboxylic acids (volatile fatty acids or VFAs) as the major components. Emissions of four VFAs (acetic acid, propanoic acid, butanoic acid and hexanoic acid) were measured from two feed sources (silage and total mixed rations (TMR)) at six Central California Dairies over a fifteen-month period. Measurements were made using a combination of flux chambers, solid phase micro-extraction fibers coupled to gas chromatography mass spectrometry (SPME/GC–MS) and infra-red photoaccoustic detection (IR-PAD for acetic acid only). The relationship between acetic acid emissions, source surface temperature and four sample composition factors (acetic acid content, ammonia-nitrogen content, water content and pH) was also investigated. As observed previously, acetic acid dominates the VFA emissions. Fluxes measured by IR-PAD were systematically lower than SPME/GC–MS measurements by a factor of two. High signals in field blanks prevented emissions from animal waste sources (flush lane, bedding, open lot) from being quantified. Acetic acid emissions from feed sources are positively correlated with surface temperature and acetic acid content. The measurements were used to derive a relationship between surface temperature, acetic acid content and the acetic acid flux. The equation derived from SPME/GC–MS measurements predicts estimated annual average acetic acid emissions of (0.7 + 1/?0.4) g m?2 h?1 from silage and (0.2 + 0.3/?0.1) g m?2 h?1 from TMR using annually averaged acetic acid content and meteorological data. However, during the summer months, fluxes may be several times higher than these values.  相似文献   

15.
Solid phase microextraction (SPME) presents many advantages over conventional analytical methods by combining sampling, preconcentration, and direct transfer of the analytes into a standard gas chromatograph (GC). Since its commercial introduction in the early 1990s, SPME has been successfully applied to the sampling and analysis of environmental samples. This paper presents an overview of the current methods for air sampling and analysis with SPME using both grab and time-weighted average (TWA) modes. Methods include total volatile organic compounds (TVOCs), formaldehyde, and several target volatile organic compounds (VOCs). Field sampling data obtained with these methods in indoor air were validated with conventional methods based on sorbent tubes. The advantages and challenges associated with SPME for air sampling are also discussed. SPME is accurate, fast, sensitive, versatile, and cost-efficient, and could serve as a powerful alternative to conventional methods used by the research, industrial, regulatory, and academic communities.  相似文献   

16.
The measurements of C2–C9 volatile organic compounds (VOC) were carried out at a site in Seoul, the capital of Korea from August 1998 to July 1999. Air samples were collected for 24 h in 6 l SUMMA canisters every 6 days. The canister samples were quantitatively analyzed by a GC/FID and GC/MS. The species with the highest mean concentration among the 70 identified was propane (7.8 ppb), followed by toluene (6.4 ppb) and ethylene (5.9 ppb). The high concentration of propane was mainly attributed to the emissions by liquefied petroleum gas (LPG) usage for cooking and heating, and butane fuel for transportation. The general trend of the seasonal variation shows higher concentrations in winter and lower ones in summer. This behavior was mainly caused by the variations of temperature, and resultant VOC source strengths, coupled with the variations of the mixing depth. According to the analysis of concentration ratios, the seasonal contributions of the major emission sources to the VOC concentrations were influenced by ambient temperature. Further, it was identified that the contributions by the use of solvents, natural gas, LPG, and butane fuel were closely related to the variations of consumption pattern according to seasons. Through the analysis of the concentration correlations between less reactive compound and highly reactive ones for summer and winter months, it was found that photochemical reactivity affects relative concentration of reactive compound.  相似文献   

17.
The MMT bag for emission source sampling: design and evaluation   总被引:1,自引:0,他引:1  
This paper presents the design and evaluation results for a metal-coated multilayer Tedlar (MMT) bag that was developed for the collection of source emissions. The applicability of the MMT bag was evaluated for a number of important greenhouse relevant gases: CO, CO2, CH4, N2O, and total hydrocarbons (THCs). The bag was tested for durability and stability for a range of concentrations of the tested compounds using both laboratory-prepared samples and real source samples. The results show that all tested compounds were more stable when stored in the MMT bag than when stored in a regular Tedlar bag. These compounds can be stored at room temperature for at least 3 months without significant changes in concentration. When properly packed, the MMT bag is durable and may be shipped by air. The MMT bag is lower in cost, lighter in weight, and easier to clean, and it requires less devices during the subsequent laboratory analysis compared with a stainless steel canister, which is often used to collect air and source samples.  相似文献   

18.
Gehrke M  Kapila CS  Nam P  Flanigan V 《Chemosphere》2001,43(4-7):479-483
A low-volume, inert sampling and enrichment device for semivolatile organic vapors is described. The device consists of two concentric fused silica capillaries. A small portion of the inter-capillary volume, cooled with a burst of compressed carbon dioxide, serves as a trap for the semivolatile organics. The low mass of the trap permits rapid sampling and desorption cycles suitable for applications requiring fast monitoring of semivolatile chemicals. The device is devoid of switching valves in the sampling train and consequently does not suffer from analyte loss due to irreversible adsorption or interference resulting from cross contamination. The device was successfully used for sampling low concentrations of highly adsorptive nitroaromatic compounds and is applicable for polychlorinated dibenzo-p-dioxins (PCDDs) and polyaromatic hydrocarbons (PAHs).  相似文献   

19.
Greenhouse gas (GHG) emissions from concentrated animal feeding operations vary by stage of production and management practices. The objective of this research was to study the effect of two dietary crude protein levels (12 and 16%) fed to beef steers in pens with or without corn stover bedding. Manure characteristics and GHG emissions were measured from feedlot pen surfaces. Sixteen equal-sized feedlot pens (19?×?23 m) were used. Eight were bedded approximately twice a week with corn stover and the remaining eight feedlot pens were not bedded. Angus steers (n = 138) were blocked by live weights (lighter and heavier) with 7 to 10 animals per pen. The trial was a 2?×?2 factorial design with factors of two protein levels and two bedding types (bedding vs. non bedding), with four replicates. The study was conducted from June through September and consisted of four ?28-day periods. Manure from each pen was scrapped once every 28 days and composite manure samples from each pen were collected. Air samples from pen surfaces were sampled in Tedlar bags using a Vac-U-Chamber coupled with a portable wind tunnel and analyzed with a greenhouse gas gas chromatograph within 24 hr of sampling. The manure samples were analyzed for crude protein (CP), total nitrogen (TN), ammonia (NH3), total volatile fatty acid (TVFA), total carbon (TC), total phosphorus (TP), and potassium (K). The air samples were analyzed for methane (CH4), carbon dioxide (CO2), and nitrous oxide (N2O) concentrations. The concentration of TN was significantly higher (p < 0.05) in manure from pens with cattle fed the high protein diets. The volatile fatty acids (VFAs) such as acetic, propionic, isobutyric, butyric, isovaleric, and valeric acids concentrations were similar across both treatments. There were no significant differences in pen surface GHG emissions across manure management and dietary crude protein levels.

Implications: Livestock manure produces odor and emits GHGs (CO2, CH4, and N2O) at different stages of production and management practices that have significant environmental concerns. Thus, it is important to measure GHG contributions from different sources and develop appropriate mitigation strategies for minimizing GHG contribution from livestock production facilities. Two dietary protein levels (12 and 16%) fed to beef steers in pens with or without corn stover bedding were studied. The results indicated that dietary protein levels and bedding vs. no bedding had very little effect on GHG emissions and manure composition under open feedlot conditions in North Dakota climatic conditions and management practices.  相似文献   

20.
The monitoring of volatile organic compounds (VOCs) at environmental levels is commonly carried out in the field using Perkin-Elmer-type sorbent-based passive or active samplers. Measurements of important trace species, such as benzene, toluene and xylenes, are often calibrated using thermal desorption standards that are liquid loaded onto the sorbent. This method is normally adopted over the method of gas loading of standards, on the grounds of ease of application and cost. We report a comparison between sorbent standards prepared by both methods using the sorbent Carbopack X and show that under the conditions used here the two show good agreement with each other. We also present work using liquid-loaded standards on the sorbents Tenax and Chromosorb-106, prepared with the solvents cyclohexane and methanol. The results indicate that, to obtain 100% recovery of the determinands from the desorbed samplers, issues such as type of solvent and sorbent combination together with purge flow should be considered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号