首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Burning incense to pay homage to deities is common in Chinese homes and temples. Air samples were collected and analyzed for carbonyls from a home and a temple in Hong Kong where incense burning occurs on a daily basis. Carbonyls in the air were trapped on a solid sorbent coated with O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine, followed by thermal desorption and subsequent GC/MS analysis. The carbonyls identified include formaldehyde, acetaldehyde, acrolein, 2-furfural, benzaldehyde, glyoxal, and methylglyoxal. The levels of the above carbonyls correlate with the intensity of the incense-burning activities. The total mixing ratios of the carbonyls in the temple exceed those in the ambient air outside the temple by 11-23 times. Formaldehyde is the most abundant species, contributing to approximately 55% of the total carbonyl mixing ratios in both the temple and the home environments during incense burning. The mixing ratio of formaldehyde ranges from 108 to 346 ppbv in the temple and averages 103 ppbv in the home during incense burning. These values exceed the World Health Organization (WHO) air quality guideline of 100 microg m(-3) (88 ppbv) for formaldehyde. The highest formaldehyde level in the temple exceeds the WHO guideline by 3 times at peak incense burning hours. The mixing ratio of acrolein in the temple ranges from 20 to 99 ppbv, approaching or exceeding the WHO air quality guideline of 50 microg m(-3) (22 ppbv) for acrolein. Our measurements indicate that incense burning significantly elevates the concentrations of a number of carbonyls, most notably formaldehyde and acrolein, in the surrounding environments. This study provides preliminary insights on indoor air quality problems created by incense burning.  相似文献   

2.
The aim of this study was to quantify personal exposure and indoor levels of the suspected or known carcinogenic compounds 1,3-butadiene, benzene, formaldehyde and acetaldehyde in a small Swedish town where wood burning for space heating is common. Subjects (wood burners, n = 14), living in homes with daily use of wood-burning appliances were compared with referents (n = 10) living in the same residential area. Personal exposure and stationary measurements indoors and at an ambient site were performed with diffusive samplers for 24 h. In addition, 7 day measurements of 1,3-butadiene and benzene were performed inside and outside the homes. Wood burners had significantly higher median personal exposure to 1,3-butadiene (0.18 microg m(-3)) compared with referents (0.12 microg m(-3)), which was also reflected in the indoor levels. Significantly higher indoor levels of benzene were found in the wood-burning homes (3.0 microg m(-3)) compared with the reference homes (1.5 microg m(-3)). With regard to aldehydes, median levels obtained from personal and indoor measurements were similar although the four most extreme acetaldehyde levels were all found in wood burners. High correlations were found between personal and indoor levels for all substances (r(s) > 0.8). In a linear regression model, type of wood-burning appliance, burning time and number of wood replenishments were significant factors for indoor levels of 1,3-butadiene. Domestic wood burning seems to increase personal exposure to 1,3-butadiene as well as indoor levels of 1,3-butadiene and benzene and possibly also acetaldehyde. The cancer risk from these compounds at exposure to wood smoke is, however, estimated to be low in developed countries.  相似文献   

3.
The vacuum bag (VB) dust from the homes of 19 asthmatic children in North Carolina (NC) was analyzed by mold specific quantitative PCR. These results were compared to the analysis of the VB dust from 176 homes in the HUD, American Healthy Home Survey of homes in the US. The Environmental Relative Moldiness Index (ERMI) was calculated for each of the homes. The mean and standard deviation (SD) of the ERMI values in the homes of the NC asthmatic children was 16.4 (6.77), compared to the HUD survey VB ERMI value mean and SD of 11.2 (6.72), and was significantly greater (t-test, p = 0.003) in the NC asthmatic children's homes. The molds Chaetomium globosum, Aspergillus fumigatus, and the Eurotium Group were the primary species in the NC homes of asthmatics, making the ERMI values significantly higher (p < 0.02 for each). Vacuum bag dust analysis may be a useful method for estimating the mold burden in a home.  相似文献   

4.
Indoor and outdoor measurements of nitrous acid and nitrogen dioxide were conducted at four homes and two offices in residential areas in Greater Cairo during winter (2000-2001) and summer (2001) seasons. Indoor nitrogen dioxide concentrations were higher than outdoor levels at the four homes, whereas indoor concentrations of nitrogen dioxide were lower than outdoor levels at the two offices, during both seasons. Indoor nitrous acid concentrations were higher than outdoor levels at all homes and offices during the period of study. The mean indoor nitrous acid concentrations were 6.8 ppb and 3.67 ppb in the four homes, whereas they were 1.42 ppb and 1.24 ppb in the two offices, during the winter and summer seasons, respectively. Indoor/outdoor ratios of nitrous acid concentration were 6.94 in the winter and 5.03 in the summer for all of the homes. However, the ratios were 1.31 and 1.61 during the winter and summer seasons, respectively, for the two offices. Insignificant positive correlation coefficients were found between indoor and outdoor concentrations of nitrous acid at homes and offices. The maximum outdoor nitrous acid concentrations were recorded during the winter season. Significant positive correlation coefficients were found between nitrous acid and nitrogen dioxide and relative humidity in homes and offices. The ratios of nitrous acid to nitrogen dioxide concentrations ranged from 0.045 to 0.16, with a mean of 0.1, in the four homes, whereas the ratios ranged from 0.026 to 0.09, with a mean of 0.059, in the two offices.  相似文献   

5.
室内空气中甲醛测定比对试验的探讨   总被引:1,自引:0,他引:1  
为了检验化学酚试剂比色法与便携式甲醛测定仪测定室内空气中甲醛方法间有无显著性差异,用2种方法做了比对试验,并对2种方法的相关性、精密性进行了分析。结果表明,2种分析方法无显著性差异。便携式甲醛分析仪具有操作简单、携带方便、直观性强等优点,有利于民用建筑室内环境中甲醛的测定。  相似文献   

6.
Indoor and outdoor measurements of formaldehyde were conducted at seven flats located in residential areas in Greater Cairo, during spring and summer seasons 1999. The mean daytime formaldehyde concentrations in kitchens, bedrooms and living rooms were 89, 100 and 100 ppb, respectively, in the seven flats. Significant positive correlations were found between the concentrations of formaldehyde found in these three rooms. On the other hand, no significant differences were found between the mean formaldehyde concentrations in these three rooms. The maximum mean concentration of formaldehyde (147 ppb) was recorded in a new flat, while the minimum concentration (43 ppb) was observed in an old flat. The maximum hourly and daytime concentrations were 350 and 225 ppb, respectively. Air temperature, relative humidity and the age of the flat are factors affecting the emission and concentration of formaldehyde. The maximum indoor and outdoor formaldehyde concentrations were recorded during the summer season. During the spring, 38% of the samples indicated that the concentration of formaldehyde in the seven flats exceeded 0.1 ppm, the American Society of Heating, Refrigerating, and Air Conditioning Engineers' (ASHRAE) standard; in the summer, this figure increased to 53%.  相似文献   

7.
The Children's Environment and Health Action Plan for Europe (CEHAPE) of WHO focuses (inter alia) on improving indoor environments where children spend most of their time. At present, only little is known about air pollution in schools and its effect on the lung function of school children. Our project was set up as an Austrian contribution to CEHAPE. In a cross-sectional approach, differences in indoor pollution in nine elementary all-day schools were assessed and 34 of these pollutants were analyzed for a relationship with respiratory health determined by spirometry using a linear regression model. Overall 596 children (aged 6-10 years) were eligible for the study. Spirometry was performed in 433 children. Socio-economic status, area of living (urban/rural), and smoking at home were included in the model as potential confounders with school-related average concentration of air pollutants as the variable of primary interest. A negative association with flow volumes (MEF(75)) was found for formaldehyde in air samples, benzylbutylphthalate and the sum of polybrominated diphenylethers in school dust. FVC and FEV(1) were negatively associated with ethylbenzene and xylenes in air samples and tris(1,3-dichlor-2-propyl)-phosphate on particulates. Although, in general, the quality of school indoor air was not worse than that reported for homes, effects on the respiratory health of children cannot be excluded. A multi-faceted strategy to improve the school environment is needed.  相似文献   

8.
在甲醛法测定空气中二氧化硫的基础上,建立了一种测定空气中甲醛的新方法。该方法所用设备和材料与甲醛法测定空气中的二氧化硫相同,不使用含汞试剂,用亚硫酸钠固定标准溶液和吸收液中的甲醛,用氢氧化钠分解羟甲磺酸释放已被固定的甲醛,以副玫瑰苯胺和亚硫酸钠为显色剂绘制标准曲线进行定量。当采集空气30L时,检出限为0.01mgm3,最低检测浓度为0.03mgm3,适用于环境空气及室内空气中甲醛的测定。  相似文献   

9.
An automatic monitor has been developed for measuring formaldehyde in air using a sensitive tape for formaldehyde. It is based on the color change of the tape on reaction with formaldehyde. The porous cellulose tape, containing silica gel as an absorbent and impregnated with the processing solution containing hydroxylamine sulfate, Methyl Yellow (pH indicator; pH 2.9-4.0, red-yellow), glycerin and methanol, was found to be a highly sensitive means of detecting formaldehyde and maintains a stable sensitivity. When the tape was exposed to a sample of air containing formaldehyde, the color of the tape changed from yellow to red. The degree of color change was proportional to the concentration of formaldehyde at a constant sampling time and flow rate, and it could be recorded by measuring the intensity of reflected light (555 nm). The tape could be used to detect down to 0.08 ppm (World Health Organization standard) of formaldehyde with a sampling time of 30 min and a flow rate of 100 mL min-1. Reproducibility tests showed that the relative standard deviation of response (n = 10) was 3.8% for 0.1 ppm formaldehyde. The monitor is simple, specific, capable of unattended operation and is recommended for both laboratory and field operation.  相似文献   

10.
室内空气甲醛的现场快速监测技术已成为环境监测的热点研究领域,旨在为普通家庭提供室内空气甲醛现场监测方法。优化了甲醛吸收液用量、自然吸收时间及吸收液与空气接触面积对监测方法的影响,制作了用于目测室内空气中甲醛含量的标准比色卡,方法简便、快速、经济、实用,可望在普通家庭中得到广泛应用。  相似文献   

11.
Spectrophotometry in combination with ionic liquid-based dispersive liquid–liquid microextraction (DLLME) was applied for the extraction and determination of formaldehyde in real samples. The method is based on the reaction of formaldehyde with methyl acetoacetate in the presence of ammonia. The variation in the absorbance of the reaction product was measured at 375?nm. An appropriate mixture of ethanol (disperser solvent) and ionic liquid, 1-hexyl-3-methylimidazoliumhexafluoro-phosphate [C6MIM][PF6] (extraction solvent) was rapidly injected into a water sample containing formaldehyde. After extraction, sedimented phase was analyzed by spectrophotometry. Under the optimum conditions, the calibration graph was linear in the range of 0.1–20?ng?mL?1 with the detection limit of 0.02?ng?mL?1 and limit of quantification of 0.08?ng?mL?1 for formaldehyde. The relative standard deviation (RSD%, n?=?5) for the extraction and determination of 0.8?ng?mL?1 of formaldehyde in the aqueous samples was 2.5%. The results showed that DLLME is a very simple, rapid, sensitive, and efficient analytical method for the determination of trace amounts of formaldehyde in wastewaters and detergents, and suitable results were obtained.  相似文献   

12.
The aim of this study was to estimate mite antigen exposure in farming environments by passive sampling of airborne dust. Antigen concentrations were measured with enzyme immunoassays specific for three storage mites (SM): Acarus siro, Lepidoglyphus destructor, Tyrophagus putrescentiae and the house dust mite (HDM) Dermatophagoides pteronyssinus. Dust samples were collected with electrostatic dust fall collectors (EDCs) in three different areas of cattle farms. EDCs were placed in cow stables (working area), in changing rooms (transit area) and in different rooms of farmer dwellings (living area). Mite concentrations in the living area of farm homes were compared to those of urban homes. In dust samples from stables, antigens of all four mite species could be detected. The highest exposure level was to L. destructor (median 56.7 μg/m(2)), the lowest to A. siro (median 14.4 μg/m(2)). Mite concentrations of different species showed no correlation within the cow stables. In comparison to stables, the median mite concentrations in farm homes were significantly lower, ranging from below the detection limit to 1.5 μg/m(2). Antigens of SM were predominantly found in changing rooms and kitchens, and HDM antigens were mainly detected in bedrooms. Antigens of all mites were measured the least often in living rooms. T. putrescentiae was the most prevalent mite in all room types, and the exposure levels correlated strongly between different rooms. The number of SM positive samples in farm homes was considerably higher than in urban homes, while the percentage of HDM positive samples did not differ significantly.  相似文献   

13.
A sensitive spectrofluorimetric-FIA (flow injection analysis) method for formaldehyde (HCHO) determination was improved with the aim of analysing seawater samples.The fluorescence emission versus HCHO concentration shows a linear pattern from sub microg L(-1) to about 1000 microg L(-1). The reproducibility at 15 ppb level is about 2%. Interferences from other aldehydes were checked; only glyoxal shows a significative interference, but only when its concentration is about 6000 times higher than that of formaldehyde. Superficial (microlayer, just sub-pack or sea-ice free sea surface) and deep (along the water column, sub-pack or in sea-ice free areas) seawater samples were collected near the coast at Terra Nova Bay (Ross Sea, Antarctica) during the 1998/1999 and 2001/2002 Italian Antarctic Expedition. We report here the preliminary results of the spectrofluorimetric-FIA determination of the HCHO content. The mean seawater superficial formaldehyde concentration was 15 microg L(-1); the concentration along the water column ranged between 4.5 to over 40 microg L(-1)(20 microg L(-1) mean concentration), usually with a maximum value for the 30 m depth, corresponding to a fluorescence maximum. The sampling was repeated 7 times in the austral summer in order to evaluate seasonal changes in the formaldehyde concentration/seawater depth profiles. The results show changes in the formaldehyde concentration at different depths.  相似文献   

14.
采用Airpak软件模拟研究在通风速率、源项强度和源项面积多因素作用下的室内甲醛扩散规律。结果表明,在室内甲醛初始为零时,源项散发甲醛后,在2000 s内室内甲醛浓度升高较快,之后处于平衡状态。在通风速率加倍时甲醛最高浓度降低56%,源项强度减半时甲醛最高浓度降低16%,源项散发面积减少37%时甲醛最高浓度降低24%。说明通风速率对室内甲醛浓度的影响最大,其次依次为源项散发面积和源项强度。  相似文献   

15.
An investigation of contemporary exposure to formaldehyde and organic solvents has been carried out during surface coating with acid-curing lacquers and paints in the Norwegian woodworking and furniture industry over a period of 3 years. The investigation covered 27 factories of different sizes and with different types of production, and totally 557 parallel formaldehyde and solvent samples were collected. The formaldehyde concentration (geometric mean) was 0.15 ppm (range 0.01-1.48 ppm) with about 10% of the samples exceeding the Norwegian occupational exposure limit of 0.5 ppm. The solvent concentration as additive effect (geometric mean) was 0.13 (range 0.0004-5.08) and about 5% of the samples exceeded the Norwegian occupational exposure limit. The most frequently occurring solvents from acid-curing lacquers were n-butyl acetate, ethanol, ethyl acetate and 1-butanol, which were found in 88-98% of the samples. Toluene, n-butyl acetate and 1-butanol were the only solvents with maximum concentrations exceeding their respective occupational exposure limits. Curtain painting machine operators were exposed to the highest concentrations of both formaldehyde (geometric mean 0.51 ppm, range 0.08-1.48 ppm) and organic solvents (additive effect, geometric mean 1.18, range 0.02-5.08). Other painting application work tasks such as automatic and manual spray-painting, manual painting and dip painting, showed on average considerably lower concentrations of both formaldehyde (geometric means 0.07-0.16 ppm) and organic solvents (additive effect, geometric mean 0.02-0.18). Non-painting work tasks also displayed moderate concentrations of formaldehyde (geometric means 0.11-0.17 ppm) and organic solvents (additive effect, geometric mean 0.04-0.07).  相似文献   

16.
室内甲醛污染及对人体健康的影响   总被引:4,自引:0,他引:4  
通过对三种不同类型居室内甲醛监测表明,甲醛浓度与室内装饰、吸烟和燃料的不完全燃烧有关.兰州地区夏季室内甲醛超标率高,为41.0%~51.3%.室内主要污染物除TSP以外,甲醛居第2位,且一天中浓度最高值在中午.新建居室比普通居室甲醛浓度高,在所有情况下,室内浓度高于室外.  相似文献   

17.
多波长法用于减小浊度对水源水中甲醛测定结果的影响   总被引:1,自引:1,他引:0  
比较了减小水样浊度对样品结果影响的各种方法,包括过滤法、双波长法、三波长法,3种方法均基于乙酰丙酮分光光度法,测定波长均为414 nm。结果表明,以480 nm为参比波长的双波长法所得方法检出限为0.027 mg/L,采用470 nm与360 nm、460 nm与370 nm、450 nm与380 nm 3对参比波长的三波长法测得方法检出限为0.025~0.028 mg/L,这些方法用于检测0.100 mg/L标准点样品时,检测结果 RSD介于8.0%~8.6%。双波长法适合低浊度样品的直接分析,而浊度较高或双波长法测得结果大于方法检出限时,应采用三波长法进行定量分析,他们的使用有助于提高方法的准确度及减少工作量。用于地表水样品分析时,0.200、0.400 mg/L加标样品的回收率介于90.3%~101%,对应RSD介于0.0%~4.2%。  相似文献   

18.
Accurate measurement of bacterial and viral abundance in coastal marine environments is important to understand the dynamics of microbial communities in these ecosystems. In this study, the effect of formaldehyde preservation on the abundance of bacteria and viruses in water samples from Cochin Backwater was determined by SYBR Green I staining and epifluorescence microscopy. The counts were determined for 45 days in samples fixed with 1?C6% formaldehyde. The results suggest rapid decline in counts of bacteria and viruses in samples preserved in formaldehyde, and the decline increased with increase in the final concentration of formaldehyde in the sample. The initial bacterial and viral counts in the sampling site were 5.2 × 106/ml and 3.9 × 107/ml, respectively. The bacterial count dropped by 5.1%, 53.3%, 55.7%, and 85% after 1, 7, 15, and 45 days, respectively, in sample fixed with 1% formaldehyde. The decline in viral counts was higher, being 32.4%, 47.9%, 68.1%, and 93% after 1, 7, 15, and 45 days, respectively. Storage of fixed samples at ??20°C did not halt the decline in microbial counts, suggesting that, irrespective of storage temperature, formaldehyde-fixed samples lead to underestimation of microbial counts.  相似文献   

19.
高效液相色谱法分离和测定甲醛和苯酚   总被引:2,自引:0,他引:2  
本文讨论了高效液相色谱分离和测定甲醛和苯酚的条件,并对酚醛树脂生产废水进行了实际测定,结果令人满意。  相似文献   

20.
A new method utilizing the diffusive sampling of formaldehyde in air has been developed. Formaldehyde is sampled with the use of a glass fiber filter impregnated with N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH) and phosphoric acid. The formaldehyde hydrazone formed is desorbed from the filter with acetonitrile and determined by high-performance liquid chromatography (HPLC) with UV/visible detection at 474 nm. The sampling rate was determined to be 24.7 mL min-1 with a relative standard deviation of 7% for 48 experiments. The measured sampling rates were not dependent on the formaldehyde concentration (0.1-1.0 mg m-3), sampling time (15-482 min) or relative humidity (20-85%). The detection limit was 70 micrograms m-3 for a 15 min sampling period and 2 micrograms m-3 for an 8 h sampling period.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号