首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
This study comprises the first application of the Passive Flux Meter (PFM) for the measurement of chlorinated aliphatic hydrocarbon (CAH) mass fluxes and Darcy water fluxes in groundwater at a European field site. The PFM was originally developed and applied to measurements near source zones. The focus of the PFM is extended from near source to plume zones. For this purpose, 48 PFMs of 1.4 m length were constructed and installed in eight different monitoring wells in the source and plume zone of a CAH-contaminated field site located in France. The PFMs were retrieved, sampled, and analyzed after 3 to 11 weeks of exposure time, depending on the expected contaminant flux. PFM evaluation criteria include analytical, technical, and practical aspects as well as conditions and applicability. PFM flux data were compared with so-called traditional soil and groundwater concentration data obtained using active sampling methods. The PFMs deliver reasonable results for source as well as plume zones. The limiting factor in the PFM applicability is the exposure time together with the groundwater flux. Measured groundwater velocities at the field site range from 2 to 41 cm/day. Measured contaminant flux data raise up to 13 g/m2/day for perchloroethylene in the plume zone. Calculated PFM flux averaged concentration data and traditional concentration data were of similar magnitude for most wells. However, both datasets need to be compared with reservation because of the different sampling nature and time. Two important issues are the PFM tracer loss during installation/extraction and the deviation of the groundwater flow field when passing the monitoring well and PFM. The demonstration of the PFM at a CAH-contaminated field site in Europe confirmed the efficiency of the flux measurement technique for source as well as plume zones. The PFM can be applied without concerns in monitoring wells with European standards. The acquired flux data are of great value for the purpose of site characterization and mass discharge modeling, and can be used in combination with traditional soil and groundwater sampling methods.  相似文献   

2.
In this work, we present a stochastic optimal control framework for assisting the management of the cleanup by pump-and-treat of polluted shallow aquifers. In the problem being investigated, hydraulic conductivity distribution and dissolved contaminant plume location are considered as the uncertain variables. The framework considers the subdivision of the cleanup horizon in a number of stress periods over which the pumping policy implemented until that stage is dynamically adjusted based upon new information that has become available in the previous stages. In particular, by following a geostatistical approach, we study the idea of monitoring the cumulative contaminant mass extracted from the installed recovery wells, and using these measurements to generate conditional realizations of the hydraulic conductivity field. These realizations are thus used to obtain a more accurate evaluation of the initial plume distribution, and modify accordingly the design of the pump-and-treat system for the remainder of the remedial process. The study indicates that measurements of contaminant mass extracted from pumping wells retain valuable information about the plume location and the spatial heterogeneity characterizing the hydraulic conductivity field. However, such an information may prove quite soft, particularly in the instances where recovery wells are installed in regions where contaminant concentration is low or zero. On the other hand, integrated solute mass measurements may effectively allow for reducing parameter uncertainty and identifying the plume distribution if more recovery wells are available, in particular in the early stages of the cleanup process.  相似文献   

3.
When only few monitoring wells are available to assess the extent and level of groundwater contamination, inversion of concentration breakthrough curves acquired during an integral pumping test can be used as an alternative quantification method. The idea is to use concentration-time series recorded during integral pumping tests through an inversion technique to estimate contaminant mass fluxes crossing a control plane. In this paper, we examine how a longitudinal concentration gradient along a contaminant plume length scale affects the estimated inversed-concentration distribution and its associated mass flux. The analytically inversed-concentration distribution at the imaginary control plane (ICP) is compared to a numerically generated concentration distribution, treating the latter one as a "real contaminant plume" characterized by the presence of a longitudinal concentration gradient. It is found that the analytically inversed-concentration can lead to overestimation or underestimation of concentration distribution values depending on the transport time period and dispersivity values. At lower dispersivity values, with shorter transport time periods, the analytically inversed-concentration distribution overestimates the "real" concentration distribution. A better fit of the estimated concentration distribution to the "real" one is observed when the transport time period increases, i.e. when the advective front has already crossed the ICP. However, for higher dispersivity values, underestimation of the real concentration distribution is observed. Deviation of the inversed-concentration distribution from the "real" one is assessed for a site-specific concentration gradient term. A concentration gradient adjusted contaminant mass flux is thus formulated to evaluate groundwater contamination levels at a given time period through an ICP. This concentration gradient ratio can indicate whether the ICP is well positioned to evaluate accurately contaminant mass fluxes which are representative of groundwater contamination levels.  相似文献   

4.
When only few monitoring wells are available to assess the extent and level of groundwater contamination, inversion of concentration breakthrough curves acquired during an integral pumping test can be used as an alternative quantification method. The idea is to use concentration–time series recorded during integral pumping tests through an inversion technique to estimate contaminant mass fluxes crossing a control plane. In this paper, we examine how a longitudinal concentration gradient along a contaminant plume length scale affects the estimated inversed-concentration distribution and its associated mass flux. The analytically inversed-concentration distribution at the imaginary control plane (ICP) is compared to a numerically generated concentration distribution, treating the latter one as a “real contaminant plume” characterized by the presence of a longitudinal concentration gradient. It is found that the analytically inversed-concentration can lead to overestimation or underestimation of concentration distribution values depending on the transport time period and dispersivity values. At lower dispersivity values, with shorter transport time periods, the analytically inversed-concentration distribution overestimates the “real” concentration distribution.A better fit of the estimated concentration distribution to the “real” one is observed when the transport time period increases, i.e. when the advective front has already crossed the ICP. However, for higher dispersivity values, underestimation of the real concentration distribution is observed. Deviation of the inversed-concentration distribution from the “real” one is assessed for a site-specific concentration gradient term. A concentration gradient adjusted contaminant mass flux is thus formulated to evaluate groundwater contamination levels at a given time period through an ICP. This concentration gradient ratio can indicate whether the ICP is well positioned to evaluate accurately contaminant mass fluxes which are representative of groundwater contamination levels.  相似文献   

5.
At many "real world" field sites, the number of available monitoring wells is limited due to economic or geological reasons. Under such restricted conditions, it is difficult to perform a reliable field investigation and to quantify primary lines of evidence for natural attenuation (NA), like the documentation of a decrease of contaminant mass flux in flow direction. This study reports the results of a groundwater investigation at a former manufactured gas plant situated in a Quaternary river valley in southwest Germany. The location, infrastructure and aquifer setting are typical of many industrial sites in Germany. Due to difficult drilling conditions (coarse glaciofluvial gravel deposits and an anthropogenic fill above the aquifer), only 12 monitoring wells were available for the investigation and localisation of the contaminant plume. These wells were situated along three control planes (CP) downgradient from the contaminant source, with four wells along each plane. Based on the sparse set of monitoring wells, field scale mass fluxes and first-order natural attenuation rate constants of benzene, toluene, ethylbenzene, and o-xylene and p-xylene (BTEX) and low molecular weight polycyclic aromatic hydrocarbons (PAH) were estimated utilizing different point scale and also a new integral investigation method. The results show that even at a heterogeneous site with a sparse monitoring network point scale investigation methods can provide reliable information on field scale natural attenuation rates, if a dependable flow model or tracer test data is available. If this information is not available, only the new integral investigation method presented can yield adequate results for the quantification of contaminant mass fluxes under sparse monitoring conditions.  相似文献   

6.
In this paper, the integral groundwater investigation method is used for the quantification of PCE and TCE mass flow rates at an industrialized urban area in Linz, Austria. In this approach, pumping wells positioned along control planes perpendicular to the groundwater flow direction are operated for a time period on the order of days and sampled for contaminants. The concentration time series of the contaminants measured during operation of the pumping wells are then used to determine contaminant mass flow rates, mean concentrations and the plume shapes and positions at the control planes. The three control planes used in Linz were positioned downstream of a number of potential source zones, which are distributed over the field site. By use of the integral investigation method, it was possible to identify active contaminant sources, quantify the individual source strength in terms of mass flow rates at the control planes and estimate the contaminant plume position relative to the control planes. The source zones emitting the highest PCE and TCE mass flow rates could be determined, representing the areas where additional investigation and remediation activities will be needed. Additionally, large parts of the area investigated could be excluded from further investigation and remediation activities.  相似文献   

7.
Field-scale characterisations of contaminant plumes in groundwater, as well as source zone delineations, are associated with uncertainties that can be considerable. A major source of uncertainty in environmental datasets is due to variability of sampling results, as a direct consequence of the heterogeneity of environmental matrices. We develop a methodology for quantifying uncertainties in field-scale mass flow and average concentration estimations, using integral pumping tests (IPTs), where the contaminant concentration is measured as a function of time in a pumping well. This procedure increases the sampling volume and reduces the effect of small-scale variability that may bias point-scale measurements. In particular, using IPTs, the interpolation uncertainty of conventional point-scale measurements is transformed to a quantifiable uncertainty related to the (unknown) plume position relative to the pumping well. We show that this plume position uncertainty generally influenced the predicted mass flows and average concentrations (of acenapthene, benzene and CHCs) to a greater extent than a boundary condition uncertainty related to the local water balance, considering 19 control planes at a highly heterogeneous industrial site in southwest Germany. Furthermore, large (order of magnitude) uncertainties only occurred if the conditions were strongly heterogeneous in the nearest vicinity of the well. We also develop a consistent methodology for an assessment of the combined effect of uncertainty in hydraulic conditions and uncertainty in reactive transport parameters for delimiting of both contaminant source zones and zones absent of source, based on (downgradient) IPTs.  相似文献   

8.
Groundwater and contaminant fluxes were measured, using the passive flux meter (PFM) technique, in wells along a longitudinal transect passing approximately through the centerline of a trichloroethylene (TCE) plume at a former manufacturing plant located in the Midwestern US. Two distinct zones of hydraulic conductivity were identified from the measured groundwater fluxes; a 6-m-thick upper zone ( approximately 7 m to 13 m below the ground surface or bgs) with a geometric mean Darcy flux (q(0)) of 2 cm/day, and a lower zone ( approximately 13 m to 16.5m bgs) with a q(0) approximately 15 cm/day; this important hydrogeologic feature significantly impacts any remediation technology used at the site. The flux-averaged TCE concentrations estimated from the PFM results compared well with existing groundwater monitoring data. It was estimated that at least 800 kg of TCE was present in the source zone. The TCE mass discharge across the source control plane (85 m x 38 m) was used to estimate the "source strength" ( approximately 365 g/day), while mass discharges across multiple down-gradient control planes were used to estimate the plume-averaged, TCE degradation rate constant (0.52 year(-1)). This is close to the rate estimated using the conventional centerline approach (0.78 year(-1)). The mass discharge approach provides a more robust and representative estimate than the centerline approach since the latter uses only data from wells along the plume centerline while the former uses all wells in the plume.  相似文献   

9.
An optimization methodology for designing groundwater quality monitoring networks applicable to stochastic flow fields is presented and evaluated. The approach sets itself apart from previous techniques by incorporating the time dimension directly into the objective function. This function is extremized using a directed partial enumeration strategy guided by physical considerations related to transport processes. The result is a set of monitoring well locations and a sampling schedule that minimizes plume characterization error while satisfying constraints on the maximum number of wells and allowable number of active wells. The method is evaluated using hypothetical plumes with varying degrees of heterogeneity. Results indicate that the proposed approach is successful in generating near-optimal sampling networks that satisfy all imposed constraints. Monitoring networks with as little as three active wells and a total of 12 wells are found to provide adequate plume characterization for low toxicity contaminants.  相似文献   

10.
Forensic analyses of chlorinated hydrocarbon plumes typically entail reviews of site records, flow and transport modeling, and analysis of indicator compounds to gain insights into the behavior of a contaminant plume in the subsurface. Such approaches are directed toward unraveling the specific circumstances associated with the disposal history and hydrogeology of a site. A complimentary approach is to compare the behavior of a particular plume with a population of plumes from other sites that may be influenced by similar mechanisms (e.g. transformation processes such as reductive dehalogenation). In other words, hypotheses pertaining to plume behavior can be tested against a knowledge base of what is typical behavior and what is not. To address this proposed methodology, three example applications of statistical techniques to a multi-site data set are presented to provide background for problems that may be pertinent to forensic analyses. These examples include measuring the frequency of association between selected chlorinated hydrocarbon compounds, assessing the effects of transformation processes on temporal concentration trends in populations of groundwater monitoring wells, and dating plumes, in a relative sense, by concentration correlation analyses. In each case, the results of the statistical analyses are consistent with expectation, indicating that meaningful trends in chlorinated hydrocarbon plume behavior may be discerned from a diverse multi-site data set.  相似文献   

11.
Finding the location and concentration of contaminant sources is an important step in groundwater remediation and management. This discovery typically requires the solution of an inverse problem. This inverse problem can be formulated as an optimization problem where the objective function is the sum of the square of the errors between the observed and predicted values of contaminant concentration at the observation wells. Studies show that the source identification accuracy is dependent on the observation locations (i.e., network geometry) and frequency of sampling; thus, finding a set of optimal monitoring well locations is very important for characterizing the source. The objective of this study is to propose a sensitivity-based method for optimal placement of monitoring wells by incorporating two uncertainties: the source location and hydraulic conductivity. An optimality metric called D-optimality in combination with a distance metric, which tends to make monitoring locations as far apart from each other as possible, is developed for finding optimal monitoring well locations for source identification. To address uncertainty in hydraulic conductivity, an integration method of multiple well designs is proposed based on multiple hydraulic conductivity realizations. Genetic algorithm is used as a search technique for this discrete combinatorial optimization problem. This procedure was applied to a hypothetical problem based on the well-known Borden Site data in Canada. The results show that the criterion-based selection proposed in this paper provides improved source identification performance when compared to uniformly distributed placement of wells.  相似文献   

12.
Changes in contaminant fluxes resulting from aggressive remediation of dense nonaqueous phase liquid (DNAPL) source zone were investigated at two sites, one at Hill Air Force Base (AFB), Utah, and the other at Ft. Lewis Military Reservation, Washington. Passive Flux Meters (PFM) and a variation of the Integral Pumping Test (IPT) were used to measure fluxes in ten wells installed along a transect down-gradient of the trichloroethylene (TCE) source zone, and perpendicular to the mean groundwater flow direction. At both sites, groundwater and contaminant fluxes were measured before and after the source-zone treatment. The measured contaminant fluxes (J; ML(-2)T(-1)) were integrated across the well transect to estimate contaminant mass discharge (M(D); MT(-1)) from the source zone. Estimated M(D) before source treatment, based on both PFM and IPT methods, were approximately 76 g/day for TCE at the Hill AFB site; and approximately 640 g/day for TCE, and approximately 206 g/day for cis-dichloroethylene (DCE) at the Ft. Lewis site. TCE flux measurements made 1 year after source treatment at the Hill AFB site decreased to approximately 5 g/day. On the other hand, increased fluxes of DCE, a degradation byproduct of TCE, in tests subsequent to remediation at the Hill AFB site suggest enhanced microbial degradation after surfactant flooding. At the Ft. Lewis site, TCE mass discharge rates subsequent to remediation decreased to approximately 3 g/day for TCE and approximately 3 g/day for DCE approximately 1.8 years after remediation. At both field sites, PFM and IPT approaches provided comparable results for contaminant mass discharge rates, and show significant reductions (>90%) in TCE mass discharge as a result of DNAPL mass depletion from the source zone.  相似文献   

13.
A new simulation-optimization methodology is developed for cost-effective sampling network design associated with long-term monitoring of large-scale contaminant plumes. The new methodology is similar in concept to the one presented by Reed et al. (Reed, P.M., Minsker, B.S., Valocchi, A.J., 2000a. Cost-effective long-term groundwater monitoring design using a genetic algorithm and global mass interpolation. Water Resour. Res. 36 (12), 3731-3741) in that an optimization model based on a genetic algorithm is coupled with a flow and transport simulator and a global mass estimator to search for optimal sampling strategies. However, this study introduces the first and second moments of a three-dimensional contaminant plume as new constraints in the optimization formulation, and demonstrates the proposed methodology through a real-world application. The new moment constraints significantly increase the accuracy of the plume interpolated from the sampled data relative to the plume simulated by the transport model. The plume interpolation approaches employed in this study are ordinary kriging (OK) and inverse distance weighting (IDW). The proposed methodology is applied to the monitoring of plume evolution during a pump-and-treat operation at a large field site. It is shown that potential cost savings up to 65.6% may be achieved without any significant loss of accuracy in mass and moment estimations. The IDW-based interpolation method is computationally more efficient than the OK-based method and results in more potential cost savings. However, the OK-based method leads to more accurate mass and moment estimations. A comparison of the sampling designs obtained with and without the moment constraints points to their importance in ensuring a robust long-term monitoring design that is both cost-effective and accurate in mass and moment estimations. Additional analysis demonstrates the sensitivity of the optimal sampling design to the various coefficients included in the objective function of the optimization model.  相似文献   

14.
Contamination of groundwater constrains its uses and poses a serious threat to the environment. Once groundwater is contaminated, the cleanup may be difficult and expensive. Identification of unknown pollution sources is the first step toward adopting any remediation strategy. The proposed methodology exploits the capability of a universal function approximation by a feed-forward multilayer artificial neural network (ANN) to identify the sources in terms of its location, magnitudes, and duration of activity. The back-propagation algorithm is utilized for training the ANN to identify the source characteristics based on simulated concentration data at specified observation locations in the aquifer. Uniform random generation and the Latin hypercube sampling method of random generation are used to generate temporal varying source fluxes. These source fluxes are used in groundwater flow and the transport simulation model to generate necessary data for the ANN model-building processes. Breakthrough curves obtained for the specified pollution scenario are characterized by different methods. The characterized breakthrough curves parameters serve as inputs to ANN model. Unknown pollution source characteristics are outputs for ANN model. Experimentation is also performed with different number of training and testing patterns. In addition, the effects of measurement errors in concentration measurements values are used to show the robustness of ANN based methodology for source identification in case of erroneous data.  相似文献   

15.
The spatial pattern and magnitude of mass fluxes at the stream-aquifer interface have important implications for the fate and transport of contaminants in river basins. Integral pumping tests were performed to quantify average concentrations of chlorinated benzenes in an unconfined aquifer partially penetrated by a stream. Four pumping wells were operated simultaneously for a time period of 5 days and sampled for contaminant concentrations. Streambed temperatures were mapped at multiple depths along a 60m long stream reach to identify the spatial patterns of groundwater discharge and to quantify water fluxes at the stream-aquifer interface. The combined interpretation of the results showed average potential contaminant mass fluxes from the aquifer to the stream of 272microgm(-2)d(-1) MCB and 71microgm(-2)d(-1) DCB, respectively. This methodology combines a large-scale assessment of aquifer contamination with a high-resolution survey of groundwater discharge zones to estimate contaminant mass fluxes between aquifer and stream.  相似文献   

16.
The contaminant mass discharge crossing a control plane is an important metric in the assessment of natural attenuation at contaminated sites. For risk-assessment purposes, the mass discharge must be estimated together with a level of uncertainty. We present a conditional Monte Carlo approach that allows estimating the statistical distribution of mass discharge. The approach is based on conditioning multiple realizations of the hydraulic conductivity field on all data available. We jointly determine a first-order decay coefficient in each realization, leading to conditional statistical distributions of all estimated parameters and the total mass discharge. The resulting statistical distribution of contaminant mass discharges can be used in the assessment of risks at the contaminated site. The method is applied to data of hypothetical test cases, which gives the opportunity to compare estimation results to the true field. As concentration data, we account for pointlike measurements obtained in multi-level sampling wells. The obtained empirical distribution of mass discharge crossing the multi-level sampling fence could be well fitted by a log-normal distribution.  相似文献   

17.
Remediation actions at contaminated sites are based on multiple numerical model scenarios considering different parameter distributions, source positions and contaminant transport paths. In some cases the excess of scenarios is due to uncertainties in the conceptual model as a result of the spread of contamination through heterogeneities in the physical system. Reduction of project hypotheses and conceptual model uncertainty is therefore needed. This result can be achieved by coupling hydrogeological investigations with environmental forensic techniques, better localization of the source and understanding of contamination history. In this respect, in the present study, compositional fingerprinting and groundwater flow modeling were applied to a former oil storage facility where, even though a hydraulic barrier had been built to stop the hydrocarbon plume, the presence of some hydrocarbons was still found in downgradient monitoring wells. The final aim was to evaluate the efficacy of the hydraulic barrier and identify of the source of pollution. Fingerprinting results indicated pollution with a gasoline-diesel mixture much altered by water washing and/or biodegradation. Comparison of seven groundwater samples collected in wells and monitoring wells was performed by analyzing the volatile fraction (BTEX) and the total ion chromatogram (TIC), focusing attention on: n-alkanes (m/z 85), alkylcyclohexanes (m/z 83), isoprenoids (m/z 113), C4-alkylbenzenes (m/z 134), C3-C6 alkylbenzenes and polycyclic aromatic hydrocarbons (PAHs). The most probable scenario was then identified by combining the results of fingerprinting with different contaminant paths obtained using the numerical model.  相似文献   

18.
This study reports on a surfactant-based flood for tetrachloroethylene (PCE) removal from a control test cell at the Dover National Test Site. The surfactant formulation (sodium dihexyl sulfosuccinate (Aerosol-MA or AMA), isopropanol and calcium chloride) was able to achieve a high concentration of PCE in swollen micelles (supersolubilization) without vertical PCE migration. The hydraulic system included eight screened wells that were operated in both vertical circulation and line drive configurations. After 10 pore volumes of flushing, the overall PCE removal was 68% (65% of which corresponded to the surfactant flooding alone). In addition, the residual PCE saturation was reduced from 0.7% to 0.2%, and the concentration of PCE in the groundwater was reduced from 37-190 mg/L before the flushing to 7.3 mg/L after flooding. Recycling the surfactant solution reduced the required surfactant mass (and thus cost, and waste) by 90%. Close to 80% of the total PCE removal was obtained during the first five pore volumes which were operated in an upward vertical circulation flow scheme. No free oil phase was observed during the test. Further analysis of multilevel sampler data suggests that most of the trapped oil remaining in the cell was likely localized in secluded regions of the aquifer, which helps explain the lower PCE groundwater concentration after remedial activities. In summary, this field study demonstrated the feasibility of surfactant-enhanced remediation to reduce the mass in the source zone and significantly reduce the PCE aqueous concentration and therefore the risk associated with the contaminant plume.  相似文献   

19.
This paper concludes that back diffusion from one or a few thin clayey beds in a sand aquifer can cause contaminant persistence above MCLs in a sand aquifer long after the source zone initially causing the plume is isolated or removed. This conclusion is based on an intensive case study of a TCE contaminated site in Florida, with the processes evaluated using numerical modeling. At this site, the TCE DNAPL zone formed decades ago, and was hydraulically isolated by means of an innovative system performing groundwater extraction, treatment and re-injection. Treated water is re-injected in a row of injection wells situated a short distance downgradient of the extraction wells, creating a clean-water displacement front to efficiently flush the downgradient plume. This scheme avoids the creation of stagnation zones typical of most groundwater pump-and-treat systems, thereby minimizing the time for aquifer flushing and therefore downgradient cleanup. The system began operation in August 2002 and although the performance monitoring shows substantial declines in concentrations, detectable levels of TCE and degradation products persist downgradient of the re-injection wells, long after the TCE should have disappeared based on calculations assuming a nearly homogenous sand aquifer. Three hypotheses were assessed for this plume persistence: 1) incomplete source-zone capture, 2) DNAPL occurrence downgradient of the re-injection wells, and 3) back diffusion from one or more thin clay beds in the aquifer. After careful consideration, the first two hypotheses were eliminated, leaving back diffusion as the only plausible hypothesis, supported by detailed measurements of VOC concentrations within and near the clay beds and also by numerical model simulations that closely represent the field site hydrogeologic conditions. The model was also used to simulate a more generalized, hypothetical situation where more thin clayey beds occur in a sand aquifer with an underlying aquitard. While there is no doubt that DNAPL source mass reduction can eventually improve downgradient groundwater quality, the magnitude and time scale over which the improvement occurs is the major uncertainty given current characterization approaches. This study shows that even one thin clay bed, less than 0.2 m thick, can cause plume persistence due to back diffusion for several years or even decades after the flux from the source is completely isolated. Thin clay beds, which have a large storage capacity for dissolved and sorbed contaminant mass, are common in many types of sandy aquifers. However, without careful inspection of continuous cores and sampling, such thin clay beds, and their potential for causing long-term back-diffusion effects, can easily go unnoticed during site characterization.  相似文献   

20.
Methyl tert -butyl ether (MTBE) plume is controlled by many factors, primarily by groundwater flow velocity, dispersion, natural attenuation. This study employed an analytical model introduced by Domemico (1987, J. Hydrol 91 , 49-58.) to describe the MTBE concentration distribution horizontal pattern and estimated the MTBE plume length. The model was applied to 90 leaking underground storage tank cases in Los Angeles, CA, U.S.A. The analytical model was calibrated with field data for each ease using a Microsoft Excel spreadsheet program. Methyl tert -butyl ether concentrations in one source monitoring well and one to two downgradient centerline monitoring wells were used for each case study. When the centerline well is not available, the closest off-centerline wells were projected to the centerline using an ellipse trigonometry method. The model parameter values for longitudinal dispersivity, groundwater velocity, and degradation rate constant were calibrated using the field data and then used to estimate the maximum distance between source well and the plume edge. This study demonstrates that the Domenico model can be applied to MTBE plume investigation when adequate field data are available. The correlation coefficients calculated based on the results of the 90 case studies indicate that MTBE plume length has a poor correlation with MTBE concentration at the source well, and a moderate negative correlation with the degradation rate constant ( m 0.65) and u / v ratio (0.64). Furthermore, MTBE plume length has a poor correlation with the longitudinal dispersivity ( m 0.4), hydraulic gradient ( m 0.1), and groundwater velocity (0.17).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号