首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
Commercially available adsorption cooling systems use water/silica gel, water/zeolite and ammonia/ chloride salts working pairs. The water-based pairs are limited to work above 0°C due to the water high freezing temperature, while ammonia has the disadvantage of being toxic. Ethanol is a promising refrigerant due to its low freezing point (161 K), nontoxicity, zero ozone depletion, and low global warming potential. Activated carbon (AC) is a porous material with high degree of porosity (500–3000 m2/g) that has been used in wide range of applications. Using Dynamic Vapour Sorption (DVS) test facility, this work characterizes the ethanol adsorption of eleven commercially available activated carbon materials for cooling at low temperature of ?15°C. DVS adsorption results show that Maxsorb has the best performance in terms of ethanol uptake and adsorption kinetics compared to the other tested materials. The Maxsorb/ethanol adsorption process has been numerically modeled using computational fluid dynamics (CFD) and simulation results are validated using the DVS experimental measurements. The validated CFD simulation of the adsorption process is used to predict the effects of adsorbent layer thickness and packing density on cycle uptake for evaporating temperature of ?15°C. Simulation results show that as the thickness of the Maxsorb adsorbent layer increases, its uptake decreases. As for the packing density, the amount of ethanol adsorbed per plate increases with the packing density reaching maximum at 750 kg/m3. This work shows the potential of using Maxsorb/ethanol in producing low temperature cooling down to ?15°C with specific cooling energy reaching 400 kJ/kg.  相似文献   

2.
ABSTRACT

Thermal potential for cooling and heating can be achieved by new configuration of earth–air heat exchanger (EAHE). This paper presents a numerical investigation of thermal performance of a spiral-shaped configuration of EAHE intended for the summer cooling in hot and arid regions of Algeria. A commercial finite volume software (ANSYS FLUENT) has been used to carry out the transient three-dimensional simulations and the obtained results have been validated using the experimental and numerical data obtained from the literature. The agreement between our simulation results and those from literature is very satisfactory. A parametric analysis of the new geometry of (EAHE) has been performed to investigate the effect of pitch, depth, pipe length and of the flow velocity on the outlet air temperature and the EAHE’s mean efficiency as well as its coefficient of performance (COP). It has been shown that when the pitch space varies between 0.2 and 2 m the difference of outlet air temperature increases by 6 °C. When the air velocity increases from 2 to 5 m/s the mean efficiency decreases from 60 % to 33 % and the COP of the EAHE decreases from 2.84 to 0.46.  相似文献   

3.
In the United States, thermal power plant electrical generators (EGs) are large water diverters and consumptive users who need water for cooling. Retrofitting existing cooling systems to dry cooling and building new facilities with dry cooling can save water and reduce EG's vulnerability to drought. However, this can be an expensive source of water. We estimate that the cost of water saved by retrofitting cooling in existing EGs ranges from $0.04/m3 to $18/m3 depending on facility characteristics. Also water savings from building new EGs with dry cooling ranges in cost per unit water from $1.29/m3 to $2.24/m3. We compare costs with that for water development projects identified in the Texas State Water Plan. We find the water cost from converting to dry cooling is lower than many of the water development possibilities. We then estimate the impact of climate change on the cost of water saved, finding climate change can increase EG water use by up to 9.3% and lower the costs of water saved. Generally, it appears that water planners might consider cooling alterations as a cost competitive water development alternative whose cost would be further decreased by climate change.  相似文献   

4.
This study examines energetic and exergetic performances of display cases’ units used in market applications depending on different refrigerants. Besides CO2 emission potential of each refrigerant based on exergetic irreversibility obtained from analyses is calculated by the method of Total Equivalent Warming Impact (TEWI). In this study, 1 kW cooling capacity and vapor compression cooling cycle is taken as reference and refrigerants of R-22, R-134a, R-404A, and R-507 together with alternative refrigerant R-407C and R152a are examined separately. According to analyses, R-404A gas, used widely in market applications, has low performance with average COP 3.89 and average exergy efficiency 55.20%. R-152a gas has the best performance by the thermodynamics parameters including COP 4.49, exergy efficiency 63.79%, and 0.23 kW power consumption and emission parameter 14097.490 ton CO2/year. Although COP is used as a criterion to evaluate the systems, this study finally emphasizes the importance of exergy analysis and TEWI method which are important methods to determine irreversibility and emission potential of the systems.  相似文献   

5.
An untreated sewage source heat pump system directly makes use of the urban raw sewage instead of that treated by a sewage plant. At present In China, most systems adopt the indirect mode for avoiding the harmful effect of the sewage on the heat pump unit. In this article a direct-mode untreated sewage source heat pump system, which shows less theoretical analysis of the mathematical model, is theoretically designed and analyzed to simulate the system dynamic characteristics in the heating mode. The results show that the system COP changes from 4.1 to 3.4 and the heating capacity from 9.5 to 15.3 kW when the sewage inlet temperature is 12°C and the frequency increases from 18 to 32 HZ. The condenser heat-transfer coefficient increases with the frequency reducing while the change trend of evaporator heat-transfer coefficient is the opposite. The highest values of them are 303 and 1617 W.m?2?K?1, respectively. The frequency control simulation supplies the operation adjustment with theoretical instructions and some reference values.  相似文献   

6.
The present study assesses the feasibility of exploiting single- and double-basin solar stills in our daily lives. An investigation is carried out to determine the thermal performance and economic viability of making use of solar stills in water desalination. The climatic conditions of Tehran (35°44?N, 51°30?E) are considered to assess the feasibility of the basins. Transient energy and mass balance equations are utilized for modeling the thermal performance. The equations are solved by using fourth-order Runge–Kutta method in FORTRAN. The daily productivities of single- and double-basin solar stills are found to be 5.22 kg/m2 and 7.73 kg/m2, respectively, while the effect of different water masses (20–100 kg) on the productivity of each system was found to be optimum at 20 kg/m2. The results are compared with experimental work performed under different climatic conditions to examine the validity of the feasibility of basins in general. A life cycle cost analysis performed for Tehran, yields that single- and double-basin solar stills have savings-to-investment ratios of 4.2 and 4.8, respectively, indicating that they are economically feasible.  相似文献   

7.
A phase change material (PCM)-based flat plate modular heat exchanger for free cooling application, suitable for the diurnal temperature variation that prevails during the summer months of Bangalore city, India is designed and experimentally investigated. The flow and other parameters selected in the present study are meant to suit the accelerated charging of the PCM in the modular heat exchanger during the early morning hours, and to provide cool energy to the room during the daytime, by circulating the ambient air through the heat exchanger at a lower velocity. It is observed from the charging experiments that the decrease in the inlet air temperature has more influence in reducing the solidification time than the increase in the inlet air velocity. The heat exchanger designed in the present investigation is capable of maintaining the room temperature around 30°C for a longer duration of 8 hr when the heat load is 0.5 kW. It is suggested to design the modular heat exchanger with a surface area proportionate to the present heat exchanger size when the room heat load increases beyond 0.5 kW, in order to maintain a minimum comfortable temperature of 30°C in the room.  相似文献   

8.
In this communication, a new design of solar-energy-based water distillation cum drying unit with parabolic reflector has been designed, fabricated, and tested. Bitter gourd and potato slices are chosen as a drying commodity. Thermal performance of the developed system has been evaluated based on the experimental results and using linear regression analysis. Heat transfer coefficients (convective, evaporative, and radiative) for solar distillation system have been observed to be 2.48–4.09, 13.25–52.38, and 8.75–9.66 W/m2°C, respectively. Overall thermal efficiency and exergy efficiency for the distillation system has been found to be 18.77% and 1.2%, respectively. The convective heat transfer coefficient for potato slices are observed higher for initial hours and decreases as the day progresses. The average convective heat transfer coefficients for bitter gourd and potato slices have been observed as 2.18 and 5.04 W/m2°C, respectively. Experimental error in terms of percent uncertainty for bitter gourd and potato slices are found to be 42.93% and 37.06%, respectively. The present design of solar distillation and drying in a single unit could be beneficial for the development of remote, arid, and rural areas.  相似文献   

9.
Global demand for clean water supplies is on the rise due to population growth. This is also true in most cities of Iran. Non-conventional water resources must be developed to partially offset the increasing demand. In this study, the applicability and performance of rainwater harvesting (RWH) systems to supply daily non-potable water were assessed. Storage of rain falling on the roofs of residential buildings and directed into installed tanks was simulated in three cities of varying climatic conditions, namely Tabriz (Mediterranean climate), Rasht (humid climate), and Kerman (arid climate). Daily rainfall statistics for a period of 53 years as well as the information on the contributing roof area, available tank volumes and non-potable water demand were collected in each city. Typical residential buildings with roof areas of 60, 120, 180 and 240 m2 with an average of four residents in each house were considered for the study. According to the results in humid climate, it is possible to supply at least 75% of non-potable water demand by storing rainwater from larger roof areas for a maximum duration of 70% of the times. For roofs with small surface area, the supply meets 75% of non-potable water demand for a maximum duration of 45% of the times. Moreover, for Mediterranean climate, it is possible to supply at least 75% of non-potable water demand in buildings with larger roof areas for a maximum duration of 40% of the times. It is also found that in arid climate, similar duration is only 23% of the times.  相似文献   

10.
The performance of the designed tilted wick solar water distillation-cum-drying unit has been tested at water flow rates of 50 and 65 ml/min in the distillation unit. Effect of water flow rates on the heat transfer coefficients of distillation and drying unit for drying ginger has been evaluated. The energy and exergy efficiency of the distillation system have also been evaluated. Average distillates of 2.36 and 2.2 l/m2 were collected from the tilted wick solar still at flow rates of 50 and 65 ml/min, respectively. Large variation in convective and evaporative heat transfer coefficients of distillation unit has been observed at given water flow rates. Water flow rate in the distillation unit significantly affects the performance of the drying unit. Average convective heat transfer coefficients of 6.56 and 3.75 W/m2 oC have been observed for drying ginger at flow rates of 50 and 65 ml/min, respectively. Energy and exergy efficiency of the distillation unit have been found to be nearly 19% and 0.9%, respectively. Experimental uncertainty has also been evaluated for distillation and drying units. The distillate cost for the developed distillation-cum-drying unit is calculated as $0.03729/l along with dried ginger of about 2.5 kg/m2/day.  相似文献   

11.
ABSTRACT: A preliminary field experiment was conducted for trickle irrigation of winter wheat raised for grain production under arid conditions. Treated waste water was applied for trickle irrigation via a trickle system. Mean total amount of effluent applied was about 5700 m3/ha. In one of the experimental treatments, which was irrigated once a week, a grain yield of over 10,000 kg/ha was obtained, whereas in the other treatments the yields were about 8,500 kg/ha, which are above the mean yield obtained under sprinkler irrigation.  相似文献   

12.
Runoff water management is among the inherent challenges which face the sustainability of the development of arid urban centers. These areas are particularly at risk from flooding due to rainfall concentration in few heavy showers. On the other hand, they are susceptible to drought. The capital of Sudan (Khartoum) stands as exemplary for these issues. Hence, this research study aims at investigating the potential of applying rainwater harvesting (RWH) in Khartoum City Center as a potential urban runoff management tool. Rapid urbanization coupled with the extension of impervious surfaces has intensified the heat island in Khartoum. Consequently, increased frequency of heat waves and dust storms during the dry summer and streets flooding during the rainy season have led to environmental, economical, and health problems. The study starts with exposing the rainfall behavior in Khartoum by investigating rainfall variability, number of raindays, distribution of rain over the season, probability of daily rainfall, maximum daily rainfall and deficit/surplus of rain through time. The daily rainfall data show that very strong falls of >30 mm occur almost once every wet season. Decreased intra- and inter-annual rainfall surpluses as well as increased rainfall concentration in the month of August have been taking place. The 30-year rainfall variability is calculated at decade interval since 1941. Increasing variability is revealed with 1981–2010 having coefficients of variation of 66.6% for the annual values and 108.8–118.0% for the wettest months (July–September). Under the aforementioned rainfall conditions, this paper then explores the potential of RWH in Khartoum City Center as an option for storm water management since the drainage system covers only 40% of the study area. The potential runoff from the 6.5 km2 center area is computed using the United States Natural Resources Conservation Services method (US-NRCS), where a weighted Curve Number (CN) of 94% is found, confirming dominant imperviousness. Rainfall threshold for runoff generation is found to be 3.3 mm. A 24,000 m3 runoff generated from a 13.1 mm rainfall (with 80% probability and one year return period) equals the drainage system capacity. An extreme rainfall of 30 mm produces a runoff equivalent to fourfold the drainage capacity. It is suggested that the former and latter volumes mentioned above could be harvested by applying the rational method from 18% and 80% rooftops of the commercial and business district area, respectively. Based on the above results, six potential sites can be chosen for RWH with a total roof catchment area of 39,558 m2 and potential rooftop RWH per unit area of 0.033 m3. These results reflect the RWH potential for effective urban runoff management and better water resources utilization. RWH would provide an alternative source of water to tackle the drought phenomenon.  相似文献   

13.
Evaporative cooling of water in a small porous clay vessel was studied under controlled humidity conditions. In steady-state experiments performed at an ambient temperature of 23 °C, the cooling effect increased from 4.7 to 8.3 °C as the ambient relative humidity decreased from 60 to 15%. External heat and mass transfer coefficients, estimated from the steady-state measurements, were used in mathematical models to predict the experimentally observed transient temperature variation of the water under ramp changes of the ambient relative humidity. With a prototypical cool chamber containing water tested in Kolkata, India under an ambient temperature of 34.5–35 °C, the cooling effect reached a maximum of 7 °C between 3 and 3:30 PM and then declined to 4.5 °C around 6 PM.  相似文献   

14.
This study examines parametric approaches to the calculation of refrigerant-based CO2 emissions in different cooling areas. Both the exergy analyses of refrigerants, used in domestic, commercial, transportation and industrial applications, and the environmental performances regarding exergetic irreversibility are investigated separately. Then, CO2 emissions caused by systems are examined via two different parameters, I°) Environmental Impact Factor and ??°) Integrated Impact Factor (CIF). The study is based on a vapor compression cooling cycle model, commonly preferred by cooling applications, and the analyses have been made for 1 kW cooling capacity in relation to evaporator temperatures of the systems. In all cooling application, R134A gas stands out among the others in terms of coefficient of performance and exergy efficiency. Moreover, both emission analyses show that it has the lowest emission value. The paper concludes with an evaluation of the reasons for the refrigerant choice, the design and the selection of such a system, and why exergetic and environmental parameters should be preferred.  相似文献   

15.
Large scale rainwater harvesting (LSRWH) is a promising alternative to address security and flood issues in urban areas. The development and planning of a LSRWH for an eco-community involves comprehensive site-planning, systems planning and design, which includes the rainwater source collection (roof) to the storage tank, the distribution and allocation system. This paper describes a new technique for designing a LSRWH for a community of 200 houses with an average of 4 persons per house and an average total daily water demand of 160 m3. It was found that the optimal size storage tank for a 20,000 m2 roof area is 160 m3 with a 60% reliability. The application of this model to the case study revealed a significant water saving up to 58% .The total cost for this system is 443,861 USD over a life-span of 25 years.  相似文献   

16.
Phase change materials (PCMs) that can store and release heat energy over the temperature range from 363 to 393 K are crucial for solar absorption cooling, and it is worthy to seek new solid-liquid PCMs candidates that melt and crystallize in this temperature range. In this paper, (E)-3-m-tolylbut-2-enoic acid (mTBEA) was applied as a PCM candidate. Its thermal energy storage properties and thermal stability were systematically investigated. The results showed that mTBEA melted at 382.9 ± 0.5 K and crystallized at about 364 K, with a melting enthalpy (ΔfusH) of 138.4 ± 6.9 J g?1 and showed good long-term cyclic stability and thermal stability. The supercooling of mTBEA was stabilized at about 20 K, indicating that the conservation condition of melted mTBEA could be simple. In addition, the melted mTBEA could release all the absorbed thermal energy upon crystallizing. Besides, mTBEA exhibited good thermal stability for it to be applied as PCM. Hence, mTBEA is a promising PCM candidate for solar absorption cooling. Furthermore, the heat capacity of mTBEA was measured by modulated temperature differential scanning calorimetry (MTDSC) over the temperature range from 198.15 to 431.15 K, and the molar thermodynamic functions, [HT-H298.15]m and [ST-S298.15]m, were calculated based on the fitted molar heat capacity data.  相似文献   

17.
ABSTRACT: Different allocation and delivery performance ratios are used to assess operations performance in a large scale public irrigation system in Indonesia. Results from this analysis indicate that field management practices deviate substantially from the official operating procedures. The lack of application of a single, standardized procedure for planning water allocations represents a serious constraint to effective monitoring and evaluating system performance. Underestimated and unrealistic planned allocations becomes the justification for overdiversion of water, and has the effect of undermining the resolve of managers to see to it that actual flows meet planned flows. Miscalculating planned allocations, poor matches between planned flows and actual deliveries, overdiversion and misreporting have economic consequences as well. For example, strict adherence to the standard operating rule during the second dry season of 1987 would have resulted in 19,070,000 m3 less water diverted into the irrigation system from the Brantas River or, at a conservative estimate of $1.78 per 100 m3 water, a savings of $339,500. Scope exists for making improvements in management by closer adherence to the standard delivery rule, which will also facilitate proper monitoring and evaluation.  相似文献   

18.
Experimental study was performed on a single basin active solar distillation system augmented with a solar collector using evacuated solar tubes. Field tests were conducted over several days under the climatic conditions of West Texas to evaluate the effect evacuated solar tubes have on the daily distillate yield rate. To investigate the feasibility of the solar tubes, active and passive solar stills with and without exterior insulation were examined. The maximum daily production rate for the active distillation system using evacuated solar tubes and the passive distillation system was 3.6 and 1.4 kg/m2day, respectively. The results showed the augmentation of the still with evacuated solar tubes increased its production capacity by a factor of 2.63. It also increased the maximum temperature of the water in the still basin by at least 20 °C. Economic analysis shows that it is feasible to use evacuated tubular collector coupled solar still as an alternative means for reclaiming water in farmlands with a payback period of approximately 6 years.  相似文献   

19.
Rainwater tanks for larger roof areas need optimisation of tank size, which is often not carried out before installation of these tanks. This paper presents a case study of rainwater tank evaluation and design for large roof areas, located in Melbourne, Australia, based on observed daily rainfall data representing three different climatic regimes (i.e. dry average, and wet years). With the aim of developing a comprehensive Decision Support Tool for the performance analysis and design of rainwater tanks, a simple spreadsheet based daily water balance model is developed using daily rainfall data, contributing roof area, rainfall loss factor, available storage volume, tank overflow and irrigation water demand. In this case study, two (185 m3 and 110 m3) underground rainwater tanks are considered. Using the developed model, effectiveness of each tank under different climatic scenarios are assessed. The analysis shows that both the tanks are quite effective in wet and average years, however less effective in dry years. A payback period analysis of the tanks is preformed which reveals that the total construction cost of the tanks can be recovered within 15-21 years time depending on tank size, climatic conditions and future water price increase rates. For the tanks, a relationship between water price increase rates and payback periods is developed. The study highlights the need for detailed optimisation and financial analysis for large rainwater tanks to maximise the benefits.  相似文献   

20.
A hybrid cooling system consisting of both a dry section and wet section is proposed in this paper as a means to conserving energy and water by combining the benefits of both dry and wet cooling modes. A new thermodynamic coupling characteristics computing model was established to identify the best combination of dry and wet cooling subsystems in the hybrid tower throughout year-round operation based on its air thermodynamic state under the “no plume” principle. A hybrid cooling tower in Inner Mongolia, China, consisting of an elliptical tube heat exchanger with rectangular fins and counter-flow wet packing, was designed as an example under the no plume principle. The minimum number of heat exchanger units in service and the corresponding thermodynamic operating parameters were obtained under a year-round operation. The tower exhibited notable advantages in regards to water conservation compared to the traditional evaporative cooling tower at an estimated yearly savings of 3.74 × 107 kg water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号