首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Solids retention time (SRT), biological scum trapping and recycle, and the dynamic equilibrium between Nocardioform populations in the foam and the mixed liquor are the controlling factors in activated sludge foaming events caused by Nocardioform bacteria. For the operating modes described in this paper, a cured mixed liquor foaming condition (filament counts of approximately 10(5) intersections/g volatile suspended solids) was only achieved when SRT control, selective wasting, and polymer addition were in effect. Solids retention time control, with the SRT remaining below 1.5 days, and selective wasting will cure a severely foaming mixed liquor, but effects will only be observed after 3 or 4 months after implementation. The combined wastage of Nocardioform bacteria from selective wasting and SRT control can ensure long-term foam control to the operation of a pure-oxygen activated sludge system with foam-trapping features. An SRT of 0.3 days will result in the complete washout of Nocardioform bacteria from the activated sludge system, which can then operate at an SRT of 3 days free of Nocardioform. Polymer addition to mixed liquor is only effective for foam control when a large portion of the system biomass exists as a heavy layer of foam above the mixed liquor.  相似文献   

2.
The simultaneous removal of organic and nitrogen and molecular weight distribution (MWD) of residual soluble chemical oxygen demand (RSCOD) in final effluent were investigated using entrapped mixed microbial cells (EMMC) and conventional activated sludge processes. Two different types of processes using EMMC carriers demonstrated better organic and nitrogen removal performance because of the high solids retention time (SRT) compared with the activated sludge process. Regarding the RSCOD, the longer SRT process (EMMC) was affected by reducing the hydraulic retention time, resulting in the increase of high-molecular-weight materials. On the other hand, reducing the aeration period had significantly affected the MWD in the shorter SRT process (activated sludge), resulting in an increase of low-molecular-weight materials.  相似文献   

3.
Increased anaerobic selector hydraulic retention times (HRTs) in a high-purity oxygen activated sludge process resulted in an increase in soluble orthophosphate release and biodegradable chemical oxygen demand removal, confirming that enhanced biological phosphorus removal occurs at aeration solids retention times (SRTs) below 1.7 days. Under operating conditions that included biological foam trapping and recycling, an anaerobic selector with HRTs higher than 55 minutes resulted in a decrease in filament counts and effective foam control. Effective norcardioform control is achieved through the combination of metabolic selective pressure and increased soluble organic substrate removal in the anaerobic selector and low aeration SRT.  相似文献   

4.
研究构建了2个容积为1.1 L的好氧活性污泥反应器(即1号和2号反应器)1,号反应器每天直接通加低剂量臭氧(投加量为0.01 g O3/g TSS),不加臭氧的2号反应器作为对照平行运行,均采用每天换一次人工污水的充/排式操作。运行71 d的结果表明2,个反应器对人工污水COD的处理效果基本相同。反应器运行40 d后1,号反应器的污泥浓度比2号反应器的污泥浓度低1 400~1 700 mg/L并可稳定在8 200 mg/L,污泥减量化效果明显。低剂量臭氧的直接通加明显降低了胞内ATP浓度,并影响了微生物的抗氧化活性,2号反应器的平均超氧化物歧化酶和过氧化氢酶酶活比1号反应器分别高了24.3%和9.5%。PCR-DGGE对两反应器微生物种群的分析结果表明:Uncultured gammaproteobacteria bacteri-um、Nannocystis exedens和Uncultured actinobacterium为1号反应器的主要种群;而2号反应器的主要种群为Uncultured bacte-rium和Uncultured gammaproteobacteria bacterium。  相似文献   

5.
The activated sludge process is the most common method of secondary municipal wastewater treatment; solids retention time (SRT) is the key control parameter for this process. Typically, operating at long SRT is considered only for nitrification, but there are additional benefits of high SRT operation. This paper presents experimental and literature evidence to demonstrate three major additional benefits of long SRT operation: increased oxygen transfer efficiency; improved biomass particle size distribution, which results in more efficient clarification with fewer effluent particles and suspended solids; and enhanced removal of many emerging contaminants such as pharmaceuticals, personal care products, and endocrine disrupting compounds. This paper presents experimental results from several treatment plants that showed increasing oxygen transfer efficiency and particle size with increasing SRT, and evidence documenting improved removal of emerging contaminants and biodegradable organic carbon. A long-term survey of three treatment plants concludes that operating at higher SRT is not as energy intensive as typically assumed.  相似文献   

6.
The biodegradation of nitrilotriacetic acid in laboratory simulations of the activated sludge process has been studied at two different concentrations of mixed liquor suspended solids. Responses to changes in the influent nitrilotriacetic acid concentration such as those which might be associated with a “wash day” have been examined.  相似文献   

7.
Research was undertaken to analyze and verify a model that can be applied to activated sludge, integrated fixed-film activated sludge (IFAS), and moving-bed biofilm reactor (MBBR) systems. The model embeds a biofilm model into a multicell activated sludge model. The advantage of such a model is that it eliminates the need to run separate computations for a plant being retrofitted from activated sludge to IFAS or MBBR. The biofilm flux rates for organics, nutrients, and biomass can be computed by two methods-a semi-empirical model of the biofilm that is relatively simpler, or a diffusional model of the biofilm that is computationally intensive. Biofilm support media can be incorporated to the anoxic and aerobic cells, but not the anaerobic cells. The model can be run for steady-state and dynamic simulations. The model was able to predict the changes in nitrification and denitrification at both pilot- and full-scale facilities. The semi-empirical and diffusional models of the biofilm were both used to evaluate the biofilm flux rates for media at different locations. The biofilm diffusional model was used to compute the biofilm thickness and growth, substrate concentrations, volatile suspended solids (VSS) concentration, and fraction of nitrifiers in each layer inside the biofilm. Following calibration, both models provided similar effluent results for reactor mixed liquor VSS and mixed liquor suspended solids and for the effluent organics, nitrogen forms, and phosphorus concentrations. While the semi-empirical model was quicker to run, the diffusional model provided additional information on biofilm thickness, quantity of growth in the biofilm, and substrate profiles inside the biofilm.  相似文献   

8.
This paper describes results from a pilot study of a novel wastewater treatment technology, which incorporates nutrient removal and solids separation to a single step. The pseudoliquified activated sludge process pilot system was tested on grit removal effluent at flowrates of 29.4 to 54.7 m3/d, three different solid residence times (SRT) (15, 37, and 57 days), and over a temperature range of 12 to 28 degrees C. Despite wide fluctuations in the influent characteristics, the system performed reliably and consistently with respect to organics and total suspended solids (TSS) removals, achieving biochemical oxygen demand (BOD) and TSS reductions of > 96% and approximately 90%, respectively, with BOD5 and TSS concentrations as low as 3 mg/L. Although the system achieved average effluent ammonia concentrations of 2.7 to 3.2 mg/L, nitrification efficiency appeared to be hampered at low temperatures (< 15 degrees C). The system achieved tertiary effluent quality with denitrification efficiencies of 90 and 91% total nitrogen removal efficiency at a total hydraulic retention time of 4.8 hours and an SRT of 12 to 17 days. With ferric chloride addition, effluent phosphorous concentrations of 0.5 to 0.8 mg/L were achieved. Furthermore, because of operation at high biomass concentrations and relatively long biological SRTs, sludge yields were over 50% below typical values for activated sludge plants. The process was modeled using activated sludge model No. 2, as a two-stage system comprised an aerobic activated sludge system followed by an anoxic system. Model predictions for soluble BOD, ammonia, nitrates, and orthophosphates agreed well with experimental data.  相似文献   

9.
A sequencing batch reactor was used to study the possibility of harvesting polyhydroxyalkanoate (PHA) from enhanced biological phosphorus removal (EBPR) processes without compromising treatment quality. Because, in EBPR, the highest PHA concentrations are observed after exposure of the sludge to anaerobic conditions, PHA accumulation was evaluated with collection of waste activated sludge (WAS) at the end of the anaerobic stage, in addition to the traditional removal after the aerobic stage. The system achieved good phosphorus removal, regardless of the point of WAS collection. When sludge was harvested at the end of the anaerobic stage, the PHA content of the sludge ranged from 7 to 16 mg PHA/100 mg mixed liquor volatile suspended solids. Although this level of PHA production is below levels obtained with pure cultures, the demonstrated ability to harvest PHA, while simultaneously satisfying phosphorus removal in an EBPR process, is a key initial step towards of the use of wastewater treatment plants for PHA production.  相似文献   

10.
膜生物反应器(MBR)是一种高效的污水处理工艺,而微生物燃料电池(MFC)能有效降解污泥中的胞外生物有机质(EBOM)并回收电能.将MFC与MBR联用,建立了一套能够有效抑制膜污染同时回收电能的新系统——MFC-MBR耦合系统,MBR的剩余污泥经MFC处理后回流.以传统MBR为对照,对耦合系统中污水处理效果、膜污染情况和污泥混合液的性质进行研究.研究表明,耦合系统的污水处理效果没有明显恶化,COD去除率为94%,NH4+-N的去除率为92%.耦合系统能够有效减缓膜污染的发生,清洗周期延长了28%.污泥混合液的MLVSS/MLSS稳定在80% ~ 88%,系统内几乎没有无机颗粒积累.松散结合态胞外聚合物(LB-EPS)降低了48%,使污泥混合液性质得到改善.较低的污泥比阻(2.69×1012m/kg)和标准化毛细吸水时间(1.67 s·L/g MLSS),证明耦合系统污泥混合液脱水性能提高了.  相似文献   

11.
The purpose of this research was to study the fate and toxicity of triclosan (TCS) in activated sludge systems and to investigate the role of biodegradation and sorption on its removal. Two continuous-flow activated sludge systems were used; one system was used as a control, while the other received TCS concentrations equal to 0.5 and 2mgl(-1). At the end of the experiment, 1mgl(-1) TCS was added in the control system to investigate TCS behaviour and effects on non-acclimatized biomass. For all concentrations tested, more than 90% of the added TCS was removed during the activated sludge process. Determination of TCS in the dissolved and particulate phase and calculation of its mass flux revealed that TCS was mainly biodegraded. Activated sludge ability to biodegrade TCS depended on biomass acclimatization and resulted in a mean biodegradation of 97%. Experiments with batch and continuous-flow systems revealed that TCS is rapidly sorbed on the suspended solids and afterwards, direct biodegradation of sorbed TCS is performed. Regarding TCS effects on activated sludge process, addition of 0.5mgl(-1) TCS on non-acclimatized biomass initially deteriorated ammonia removal and nitrification capacity. After acclimatization of biomass, nitrification was fully recovered and further increase of TCS to 2mgl(-1) did not affect the performance of activated sludge system. The effect of TCS on organic substrate removal was minor for concentrations up to 2mgl(-1), indicating that heterotrophic microorganisms are less sensitive to TCS than nitrifiers.  相似文献   

12.
Chlorination is often used to control filamentous bulking in activated sludge systems. Pure culture and mixed-liquor experiments showed that soluble potassium (K+) concentrations increased by 2.4 mg/L (80%) and 1.5 to 3.6 mg/L (11 to 30%) in the bulk liquid phase of pure and activated sludge cultures that were exposed to chlorine, relative to unchlorinated controls. Effluent turbidity and total suspended solids from settled mixed liquor increased significantly in both short-term batch and sequencing batch reactor experiments when chlorine mass load increased above 6 milligrams of chlorine per gram mixed liquor volatile suspended solids (mg Cl2/g MLVSS) in a single dose, which correlated with a localized chlorine concentration at the dose point of 10 mg/L as Cl2 or greater. The results support the hypothesis that the glutathione-gated potassium efflux (GGKE) bacterial stress response may contribute to increased effluent turbidity associated with high doses of mixed-liquor chlorination. It is suggested that potassium is a useful parameter to monitor at full-scale facilities when determining chlorine mass doses that should be used to control filaments and minimize increases in effluent turbidity.  相似文献   

13.
Chromium species behaviour in the activated sludge process   总被引:3,自引:0,他引:3  
The purpose of this research was to compare trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) removal by activated sludge and to investigate whether Cr(VI) reduction and/or Cr(III) oxidation occurs in a wastewater treatment system. Chromium removal by sludge harvested from sequencing batch reactors, determined by a series of batch experiments, generally followed a Freundlich isotherm model. Almost 90% of Cr(III) was adsorbed on the suspended solids while the rest was precipitated at pH 7.0. On the contrary, removal of Cr(VI) was minor and did not exceed 15% in all experiments under the same conditions. Increase of sludge age reduces Cr(III) removal, possibly because of Cr(III) sorption on slime polymers. Moreover, the decrease of suspended solids concentration and the acclimatization of biomass to Cr(VI) reduced the removal efficiency of Cr(III). Batch experiments showed that Cr(III) cannot be oxidized to Cr(VI) by activated sludge. On the contrary, Cr(VI) reduction is possible and is affected mainly by the initial concentration of organic substrate, which acts as electron donor for Cr(VI) reduction. Initial organic substrate concentration equal to or higher than 1000 mgl(-1) chemical oxygen demand permitted the nearly complete reduction of 5 mgl(-1) Cr(VI) in a 24-h batch experiment. Moreover, higher Cr(VI) reduction rates were obtained with higher Cr(VI) initial concentrations, expressed in mg Cr(VI) g(-1) VSS, while decrease of suspended solids concentration enhanced the specific Cr(VI) reduction rate.  相似文献   

14.
This study investigates the effect of dispersed microorganisms and exocellular polymeric substances on biomass dewaterability. Specific resistance to filtration (SRF) was measured for biomass from a membrane bioreactor and a completely mixed activated sludge system. Both laboratory-scale reactors were fed with synthetic wastewater and operated at a high food-to-microorganism ratio (F/M) (1 to 11 kilograms chemical oxygen demand per kilogram mixed liquor volatile suspended solids per day [kgCOD/(kg MLVSS.d)]) and short solids retention times (0.25 to 5 d). The SRF values were affected by strong interactions of three parameters: (1) the mixed liquor suspended solids concentration, (2) the amount of dispersed microorganisms, and (3) the exocellular polymeric substances (EPS) concentration. At F/M smaller than 2 kg COD/(kg MLSS.d) and mixed liquor suspended solids (MLSS) concentration higher than 2000 mg/L, increasing amount of dispersed microorganisms in the biomass yielded higher SRF values. However, at high F/M (> 5 kg COD/kg MLSS.d) and low MLSS concentrations (< 600 mg/L), lower EPS concentrations resulted in slightly smaller SRF values, even though the amount of dispersed microorganisms in the biomass was much higher. Thus, at low MLSS concentrations, EPS concentrations rather than the amount of dispersed microorganisms tend to control SRF.  相似文献   

15.
Enhanced biological phosphorus removal (EBPR) from wastewater relies on the enrichment of activated sludge with phosphorus-accumulating organisms (PAOs). The presence and proliferation of glycogen-accumulating organisms (GAOs), which compete for substrate with PAOs, may be detrimental for EBPR systems, leading to deterioration and, in extreme cases, failure of the process. Therefore, from both process evaluation and modeling perspectives, the estimation of PAO and GAO populations in activated sludge systems is a relevant issue. A simple method for the quantification of PAO and GAO population fractions in activated sludge systems is presented in this paper. To develop such a method, the activity observed in anaerobic batch tests executed with different PAO/GAO ratios, by mixing highly enriched PAO and GAO cultures, was studied. Strong correlations between PAO/GAO population ratios and biomass activity were observed (R2 > 0.97). This served as a basis for the proposal of a simple and practical method to quantify the PAO and GAO populations in activated sludge systems, based on commonly measured and reliable analytical parameters (i.e., mixed liquor suspended solids, acetate, and orthophosphate) without requiring molecular techniques. This method relies on the estimation of the total active biomass population under anaerobic conditions (PAO plus GAO populations), by measuring the maximum acetate uptake rate in the presence of excess acetate. Later, the PAO and GAO populations present in the activated sludge system can be estimated, by taking into account the PAO/GAO ratio calculated on the basis of the anaerobic phosphorus release-to-acetate consumed ratio. The proposed method was evaluated using activated sludge from municipal wastewater treatment plants. The results from the quantification performed following the proposed method were compared with direct population estimations carried out with fluorescence in situ hybridization analysis (determining Candidatus Accumulibacter Phosphatis as PAO and Candidatus Competibacter Phosphatis as GAO). The method showed to be potentially suitable to estimate the PAO and GAO populations regarding the total PAO-GAO biomass. It could be used, not only to evaluate the performance of EBPR systems, but also in the calibration of potential activated sludge mathematical models, regarding the PAO-GAO coexistence.  相似文献   

16.
The present study proposes an image analysis methodology for the identification of different types of disturbances in wastewater treatment activated sludge systems. Up to date, most reported image analysis methodologies have been used in activated sludge processes with the aim of filamentous bulking detection, however, other disturbances could be foreseen in wastewater treatment plants. Such disturbances can lead to fluctuations in the biomass contents, affecting the mixed liquor suspended solids (MLSS), and in the sludge settling ability, affecting the sludge volume index (SVI). Therefore, this work focuses on predicting the MLSS and SVI parameters for different types of disturbances affecting an activated sludge system. Four experiments were conducted simulating filamentous bulking, zoogleal or viscous bulking, pinpoint floc formation, and normal operating conditions. Alongside the MLSS and SVI determination, the aggregated and filamentous biomass contents and morphology were studied as well as the biomass Gram and viability status, by means of image analysis.  相似文献   

17.
Real-time control of aeration tank operation is key to high-efficiency pollutant removal and energy savings. One of the aims of this study was to examine the potential for using redox potential (oxidation-reduction potential [ORP]) to indicate wastewater quality online in aeration tanks treating medium (chemical oxygen demand [COD] of 70 to 150 mg/L) and low (COD of 15 to 30 mg/L) pollutant-concentration wastewaters. The field-scale data provide a good relationship between ORP values and nutrient removal along the length of the aeration tanks. The ORP values increased dramatically as organic matter was removed along the aeration tanks, indicating the improvement of the bulk liquor redox status. Dissolved oxygen higher than 1.0 mg/L was necessary for good biodegradation and improvement of the liquid redox status. Nitrification occurred at higher ORP values (380 to 420 mV) than was the case for organic substrate oxidation (250 to 300 mV). The microprofiles obtained from microelectrode measurements substantiate the heterogeneity of the microbial processes inside activated sludge flocs. Because of microbial oxygen utilization, the aerobic region in the activated sludge floc was limited to the top layer (0.1 to 0.2 mm) of the activated sludge aggregate present in medium-strength wastewater, with an anoxic zone dominating inside the flocs. When dissolved oxygen in the bulk water was higher than 4.0 mg/L, the anoxic zone inside the floc disappeared. At low wastewater pollutant concentrations, the ORP and dissolved oxygen inside the activated sludge aggregates were higher than those from medium-strength wastewater. The prospect of using ORP as an online control approach for aeration tank operation and the potential reasons for activated sludge floc size varying with pollutant strengths are also discussed.  相似文献   

18.
一体化间歇曝气完全混合活性污泥法处理装置采取特殊的沉淀区构造,改变了活性污泥的循环流动方式,通过间歇曝气,反应区交替处于好氧/缺氧状态,达到了有机物高效去除、高效硝化反硝化及控制污泥膨胀的效果.该方法具有出水水质好、运行稳定、能耗低、流程简洁和操作管理方便的特点,是一种很有发展潜力的一体化中小型生活污水、城市污水处理系统.  相似文献   

19.
一体化间歇曝气完全混合活性污泥法处理装置采取特殊的沉淀区构造,改变了活性污泥的循环流动方式,通过间歇曝气,反应区交替处于好氧/缺氧状态,达到了有机物高效去除、高效硝化反硝化及控制污泥膨胀的效果.该方法具有出水水质好、运行稳定、能耗低、流程简洁和操作管理方便的特点,是一种很有发展潜力的一体化中小型生活污水、城市污水处理系统.  相似文献   

20.
Particle size distribution (PSD) analysis was used to evaluate the quality of mixed liquors collected from different activated sludge process modifications (i.e., conventional activated sludge, modified Ludzack-Ettinger, high-purity oxygen, step-anoxic, and oxidation ditch). An experiment protocol was developed to define the allowable sample holding time and provide representative and repeatable results. Samples of 26 treatment plants, with a total of 37 samples, were tested. A new indicator, called mean particle size (MPS), was introduced to describe the integrated mean particle size. The results of MPSs of three cut-off sizes (0.5 to 50, 100, and 200 microm) showed that the average size of mixed-liquor biosolids increased with increasing solids retention time (SRT), and the number of particles in the sedimentation supernatant decreased with increasing SRT. Particle deflocculation occurred after excessive sample holding time, and analysis within 12 hours generally eliminated sample holding problems. The results provide a methodology using PSD for characterizing mixed-liquor biosolids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号