首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
High resolution gas chromatography - mass spectrometry (GC-MS) has been widely used in the field of environmental sample analysis for volatile organic compounds (VOCs) (Gryder-Boutet, et al., 1988). Such a technique was applied to the analysis of VOCs at a local municipal wastewater treatment plant. The combination of purge and trap sample preparation and thermal desorption with cryofocusing technology, allows for the detection of a wide range of volatiles in wastewater and sludge samples. Results show that a large variety of organics present in samples are aliphatic and aromatic hydrocarbons. Their concentrations are in part per billion levels between 10 to 150 g/L. Others identified using this method are chlorinated hydrocarbons, sulfides and organic acids. By comparing the chromatograms of different wastewater and sludge samples collected from various treatment process units, it can be seen that most volatiles were removed or degraded after the aeration or digestion process. Information that provides an insight to the measurement of organic compounds in sludges is also discussed in this paper.  相似文献   

2.
The aim of the research involved identification and semi-quantitative determination of unknown volatile and semi-volatile organic compounds emitted to air by sewage sludge formed in the process of municipal wastewater treatment in a sewage treatment plant. Samples taken directly after completion of the technological process as well as the sludge stored on the premise of the sewage treatment plant were analyzed. A simple method using off-line headspace solid-phase microextraction combined with gas chromatography–mass spectrometry has been proposed for extraction and detection of organic pollutants. For reliable identification of compounds, combination of two independent parameters: mass spectra and linear temperature programmed retention indices were employed. Over 170 compounds of different structure were identified including aliphatic and aromatic hydrocarbons, alcohols, esters, carbonyls, as well as sulfur, nitrogen, and chlorine containing compounds. The prevailing substances included: ethyl ether, n-hexane, p-xylene, o-xylene, mesitylene, m-ethylbenzene, limonene, n-decane, n-undecane, and n-dodecane. A few compounds such as methanetiol, dimethyl polisulfide, octaatomic sulfur, phthalic anhydride, and indoles were identified in the sludge for the first time.  相似文献   

3.
A rugged and specific method based on tandem solid-phase extraction and liquid chromatography-tandem mass spectrometry for the determination of anti-infectives in raw sewage and wastewater plant effluents was developed. Analyte recoveries from spiked effluents ranged from 68 to 104%. Two specific selected reaction monitoring transitions and their peak area ratios were used to avoid false positives and confirm the presence of the targeted substances. Detection limits allowed low nanogram per litre detection (0.3-22 ng L(-1)). The method was successfully applied to real samples from the Montréal wastewater treatment plant. All the studied anti-infectives were found in the wastewater samples in concentrations ranging from 39 to 276 ng L(-1). Mean flows of anti-infectives were estimated from effluent concentrations and it was found that large amounts (>118 g day(-1) up to 830 g day(-1)) are discharged in the receiving waters of the St Lawrence River.  相似文献   

4.
A biochemical oxygen demand (BOD) monitoring system, based on electrochemically-active bacteria in combination with a microbial fuel cell, has been developed for the purpose of on-site, on-line and real-time monitoring of practical wastewater. A microbial fuel cell that had been enriched with electrochemically-active bacteria was used as the basis of the measurement system. When synthetic wastewater was fed to the system, the current generation pattern and its Coulombic yield were found to be dependent on the BOD5 of the synthetic wastewater. A linear correlation between the Coulombic yields and the BOD5 of the synthetic wastewater were established. Real wastewater obtained from a sewage treatment plant also produced a highly linear correlation between the Coulombic yield and BOD5 in the system. To examine on-site, on-line and real-time monitoring capability, the BOD monitoring system was installed at a sewage treatment plant. Over 60 days, the measurement system was successfully operated with high accuracy and good stability with the measuring period for a sample being 45 min. This application showed that the application of the measurement system was a rapid and practical way for the determination of BOD5 in water industries.  相似文献   

5.
Tris(chloro-isopropyl)phosphate (TCPP) was identified by GC-MS by comparing mass spectra and retention times to original standards. The concentrations in wastewater of a sewage treatment plant's influent and effluent were analysed (520 ng l(-1) and 380 ng l(-1), respectively (mean values). The concentrations of TCPP in the wastewater inflow exhibited a high variability. The elimination of this compound in the sewage treatment plant also exhibits a high variability but is low. Additionally the concentrations in sewage sludge of the same plant were determined (mean value 5100 ng g(-1) dry weight; 1700 ng g(-1) wet weight, respectively). For a comparison sludge samples from twenty other plants were analysed. In these samples concentrations ranging from 1000-20000 ng g(-1)(dry weight) were determined. Thus sorption to sludge does occur to some extent.  相似文献   

6.
Anthropogenic compounds that are able to disrupt the endocrine system of wildlife species are a major cause for concern and have led to a demand for new screening methods. The identification and quantification of endocrine disruptor compounds at wastewater treatment plant is of major interest to assess the endocrine activity of wastewater treatment plant discharges into the environment. This study consists of a preliminary survey of concentrations of previously selected endocrine disruptor compounds, undertaken to establish environmental concentrations and to support a biological program assay exposing freshwater fish to them. Selected endocrine disrupting chemicals (APEs, bisphenol A and 17 β-estradiol) were measured in samples from a wastewater treatment plant located in Lisbon (Portugal), using recent commercial enzyme-linked immunosorbent assay kits and also LC-MS/MS. The results show that the wastewater treatment plant treatment process is efficient on the removal of target endocrine disruptor compounds. However, environmentally significant concentrations are still present in the treated effluent. The results also show that enzyme-linked immunosorbent assay kit is suitable for routine analysis of the selected compounds. The results are also useful since the wastewater treatment plant is located in a Mediterranean region, which results in an effluent with its own characteristics.  相似文献   

7.
在污水处理厂的格栅、沉砂池、初沉池、曝气池、二沉池采集气样,同时采集相应点位水样,分析各点位氨气排放特征及其与污水指标间相关性。在格栅间、污泥脱水间收集氨气浓度分析密闭车间氨气排放量,结果表明:水气界面格栅间氨气排放浓度最高,随着处理工艺的进行,氨气排放浓度呈下降趋势;氨气排放浓度与污水中氨氮浓度及总氮浓度有较好的线性关系;沉砂池及初沉池氨气挥发速率远高于曝气池和二沉池;各工艺段氨气排放量差异较大,污水厂污水氨气排放量为922 mg/m~3,初沉池对污水厂氨气贡献率最高,为78.8%。  相似文献   

8.
建立了以环己烷为萃取剂、气相色谱法(氢火焰离子化检测器,FID)测定水质样品中可萃取性石油烃(C_(10)~C_(40))的分析方法。以正构烷烃混合标准溶液为定性和定量校准标准,以色谱峰面积总和与混合标准溶液总浓度建立校准曲线进行外标法定量。方法检出限为0.01 mg/L,经验证方法精密度和准确度良好。同时,分别以气相色谱法和红外光度法测定了地表水、污水处理厂出水、海水和化工废水等实际样品,对比实验结果表明,在可萃取性石油烃C_(10)~C_(40)的碳数范围内,气相色谱法的测试结果与红外光度法无明显差异,有较好的可比性。  相似文献   

9.
This study is planned to perform a sanitary survey of the largest sewage treatment plant in Riyadh, KSA, fortnightly for 6 months to examine its effluent quality as an example for the growing dependence on reuse of treated municipal wastewater in agricultural irrigation purposes to cope with increasing water shortage. The biological and physico-chemical parameters of 12 wastewater samples from the plant were examined using standard methods. The physico-chemical analysis indicated that the surveyed municipal wastewater treatment plant contained some of the studied parameters, such as turbidity, total suspended solids, biochemical oxygen demand, chemical oxygen demand and residual chlorine above the maximum permissible wastewater limits set by the Saudi Standards. However, heavy metal concentrations in all samples were lower than the recommended standards. Total and faecal coliform counts were above the permissible limits indicating poor sanitation level. Fifty percent of all wastewater samples were contaminated with faecal coliforms but, surprisingly, Escherichia coli were only detected in 8.3 % of the samples. Regular monitoring and enhancement of microbial and physico-chemical parameters of the wastewater quality served by different wastewater treatment plants for reuse in agricultural irrigation is recommended to preserve the environment and public health.  相似文献   

10.
对80个不同水体样品进行了环境雌激素检测,共有42个样品为阳性(阳性率52.5%),阳性样品主要来自于医疗废水、市政排污口、污水处理厂及与工业污染源废水,水源水中未检出。42个阳性样品检测值均超过EPA标准规定的壬基酚4 d平均浓度限值(6.6μg/L),其中12个样品检测值超过了该标准中规定的壬基酚小时平均浓度限值(28μg/L)。  相似文献   

11.
The occurrence and fate of eight pharmaceutical and personal care products (PPCPs) during sewage treatment has been studied in a pilot-scale treatment plant, comprising a primary settler (2.85 m(3)), an aeration tank (1.845 m(3)) and a secondary clarifier (0.5 m(3)), placed on site at a wastewater treatment works in the north west of the UK. It was fed both with raw sewage and the return liquor produced after sludge centrifugation, thus representing the most common configuration for a municipal sewage treatment plant based on the activated sludge process. Samples were taken at six different locations, including the return liquor stream, and analysed for musk fragrances and pharmaceutically active compounds belonging to various therapeutic groups such as anti-inflammatory drugs, tranquillisers and antiepileptics. Mass balances were conducted for those PPCPs that were quantifiable. The fate of the PPCPs was found to differ according to their physical-chemical characteristics. Anti-inflammatories underwent a degradation process and were almost completely removed from sewage during the biological treatment step. Musk fragrances were only partially removed, through adsorption onto the primary suspended solids and the biomass in the aerobic process, due to their strong lipophilic characteristics. The results of this study provide increasing evidence that the partial removal of these substances through the sewage treatment process contribute to the environmental occurrence of PPCPs. Consequently, existing STPs should be upgraded in order to attenuate the release of these substances into the aquatic environment.  相似文献   

12.
An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries.  相似文献   

13.
In this study, 16 polycyclic aromatic hydrocarbons (PAHs) were detected in sewage sludge samples from four wastewater treatment plants (WWTPs) in Qingdao, China. These WWTPs differ in the type of treatment used and in the origin of the wastewater. The total amounts of PAHs in digested sludges ranged from 1.9645 to 6.5752 mg/kg, which did not exceed the projected European Union cut-off limits (6 mg/kg) for sludge found in farmland, except for the Haibohe WWTP. Significant differences were observed in overall PAH values between WWTPs receiving domestic effluents and those receiving industrial effluents. The total amounts of PAHs in digested sludge from the Licunhe and Haibohe WWTPs, which mainly received industrial effluents, were markedly higher than those of the Tuandao and Huangdao WWTPs, which received only domestic effluents. The distribution of PAH compounds in digested sludges were analysed. At the Tuandao, Huangdao and Licunhe WWTPs, 2-, 3-, 4-benzene rings were predominant, accounting for 100%, 99.8% and 99.0% of the sum concentration of 16 PAHs (∑PAHs), respectively. At the Haibohe WWTP, a large number of high molecular weight PAHs (5-, 6-benzene rings) were observed, accounting for 30% of the ∑PAHs. The sum of seven carcinogenic PAHs (∑PAHs-c) ranged from 0.8694 to 3.0389 mg/kg in four WWTPs. The highest value was found in the Haibohe WWTP. Moreover, the PAH concentrations in sludges from the different treatment processes in the Licunhe and Tuandao WWTPs are discussed.  相似文献   

14.
15.
通过两次采集北京某大型污水处理厂的水样,采用HPLC-MS技术对水样中的10种PPCPs进行分析.结果显示,进水口水样中PPCPs浓度为7122.92ng/L,其中咖啡因的检出浓度最高(4490.54ng/L),污水处理厂对咖啡因的去除率大于90%(浓度为78.01ng/L).与文献报道值比较发现,该污水处理厂出水水样中PPCPs的浓度与其他国家报道的浓度基本上处于同一数量级,但污水中PPCPs的去除率都普遍低于国际水平.因此,需加强对污水处理厂水样中PPCPs的监测,完善污水处理的工艺.  相似文献   

16.
In this study, the occurrence and distribution of polycyclic aromatic hydrocarbons (PAHs) were investigated in six sludge samples collected from Guangdong Province, China. Concentrations of PAHs varying from 2,534.1 to 6,926.6 μg kg???1 (dry sludge) were observed in three municipal wastewater treatment plants with phenanthrene (Phe), fluoranthene, and pyrene being the main compounds. In addition, 682.6 μg kg???1 PAHs were detected in one sludge sample from a food processing plant, with fluorene, Phe, and chrysene being the main components. No PAHs were detected in sludge samples obtained from two cosmetic plants. The levels and distributional characteristics of PAHs, polychlorinated biphenyls (PCBs), and polycyclic musks (PMs) from the samples were also compared. The results of this comparison indicated that petrochemical refineries and road traffic played important roles in the PAH loads in sludge, while PMs primarily originated from domestic wastewater and industrial wastewater from cosmetic plants. Finally, the presence of 98.8 μg kg???1 PCBs in sludge suggested diffusional emission sources from electrical components containing PCBs.  相似文献   

17.
We analyzed water samples from the confluence of three municipal sewage treatment effluent streams, surface water, and whole carp (Cyprinus carpio) for synthetic musks for a period of 7-12 months. The lipid content of each fish was determined and compared with the concentration of musks in the whole fish tissue. Enhanced methods were used for water sampling and musk extraction. The data presented here provide insight as to the relationship between concentrations of synthetic musks in the municipal effluent and associated biota. This study confirmed the presence of polycyclic and nitro musk compounds in sewage effluent, Lake Mead water, and carp. The concentrations were found to be considerably lower than previous studies conducted in other countries. This study also provides data for polycyclic and nitro musk compounds, as well as some of the nitro musk metabolites in sewage treatment plant effluent, lake water, and carp.  相似文献   

18.
The occurrence and removal of eight endocrine disrupting compounds (EDCs), including estrone (E(1)), 17β-estradiol (E(2)), estriol (E(3)), 17α-ethinylestradiol (EE(2)), diethylstilbestrol (DES), bisphenol A (BPA), nonylphenol (NP) and octylphenol (OP), and their estrogenicities were investigated in a sewage treatment plant in Harbin city, China. The EDCs were extracted from wastewater samples by solid phase extraction (SPE) method and analyzed with gas chromatography coupled with mass spectrometry (GC-MS). The average concentrations in the influents and effluents ranged from 6.3 (EE(2)) to 1725.8 ng L(-1) (NP) and from 相似文献   

19.
Environmental pollution is one of the major problems being facedtoday due to the advent of extensive industrialization. Heavy metals are the most important contaminants in wastewater that are present in abundance and are toxic. Heavy metal contentsof sewage in the industrial estate of Aligarh (U.P.) have beendetermined by atomic absorption spectrophotometry. The analysisof samples collected from six different locations revealedsignificantly high levels of Fe, Zn, Cu, Cr and Ni. Certainbacteriological (Total bacterial count, Total coliform, Fecal coliform, and Fecal Streptococci) parameters of domestic and industrial sewage as well as soils were monitored from March1990 to January 1993. Total bacterial count, total coliform,fecal coliform and fecal streptococci were found to be lowestin all the samples of industrial wastewater compared to thosein domestic sewage and soil systems. The soil however, contained highest total culturable bacterial population. In view of the common practice of the application of sewage to agricultural land in the neighbouring area, the discharge ofindustrial wastewater without proper treatment into public sewers should be strictly prohibited.  相似文献   

20.
建立了利用气相色谱-质谱法快速筛查气态制冷剂产品中的10种热点管控类卤代烃的分析方法。采用气密性微量注射器对气态制冷剂样品进行取样,刺透瓶盖隔垫加入到顶空瓶中,自动进样;以GS-GasPro(多孔层开管,60 m×0.32 mm)为色谱柱,采用电子轰击离子源,全扫描模式采集。测试结果显示:目标物的体积分数在0.50%~100.00%范围内,相对响应因子的相对标准偏差(RSD)均小于20%;线性相关系数r均在0.999以上;检出限(3.143倍标准偏差)为0.01%~0.05%。对实际样品进行加标回收,回收率为79.5%~102%,测定值RSD为0.5%~3.1%。该方法可为快速、准确、批量筛查气态制冷剂产品中的多种热点管控类卤代烃提供技术支撑。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏