首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
选用配备了2种不同检测器(电导检测器和直流安培检测器)的离子色谱仪对稀释后过0.22μm滤膜的水样进行分析。配备有直流安培检测器的离子色谱仪测定水中碘化物的方法在0.100~20.0μg/L范围内线性关系良好,相关系数(r)=0.9999,方法检出限为0.030μg/L,测定下限为0.120μg/L,样品加标回收率为95.0%~104%,相对标准偏差为1.06%~1.64%;配备有电导检测器的离子色谱仪测定水中碘化物的方法在20.0~2.00×105μg/L范围内线性关系良好,相关系数(r)=0.9995,方法检出限为2.00μg/L,测定下限为8.00μg/L,样品加标回收率为99.0%~110%,相对标准偏差为0.71%~3.12%。离子色谱-直流安培检测器法测定水中碘化物的方法准确度高、灵敏度高、精密度好,检出限相对较低,适用于测定ρ(碘化物)≤20.0μg/L的清洁水样;离子色谱-电导检测器法主要适用于测定ρ(碘化物)≥20.0μg/L的水样。  相似文献   

2.
We describe a method for the simultaneous determination of eight kinds of phenylbenzotriazole-type mutagens (PBTA-1, -2, -3, -4, -5, -6, -7 and -8) in river water based on liquid chromatography-tandem mass spectrometry (LC/MS/MS). The application of dopant-assisted atmospheric pressure photoionization (APPI) for the detection of the PBTAs was studied. The APPI technique provided higher PBTA signal intensities than those obtained with an electrospray ionization (ESI) source, and the APPI method was used for the determination of the PBTAs. A solid-phase extraction procedure was used for the extractions of PBTA-1 through -8 from river water. The procedure was rapid and the relative standard deviations were below 15%. The detection limits of PBTA-1 through -8 in river water using the proposed method were found to range from 0.04 to 0.5 ng L(-1) and PBTAs were successfully detected in river water at sub-ng L(-1) levels.  相似文献   

3.
Concern over the presence of fecal coliform in public drinking water supplies has been expressed in recent years in Pakistan since it has been regarded as pathogenic organism of prime importance in gastroenteritis. Two major drinking water distribution systems in the Cantt area of Rawalpindi district covering the Westridge and Tench areas was monitored over a 2-month period to determine the prevalence of fecal coliform and chlorine residual. The collected samples were examined for total chlorine, free chlorine residual, chloramines, total coliforms, fecal coliforms, and turbidity. The drinking water quality monitoring in the distribution network was performed by collecting samples from water source, overhead reservoir, and residential taps. In the Westridge area, total chlorine varied from the lowest value of 0.27 mg/L at Station # W-5 to the highest value of 0.42 mg/L at Station # W-2, total coliforms varied from 1.1 to 3.6 most probable number (MPN)/100 mL with presence of Escherichia coli in all samples, total dissolved solids (TDS) ranged from 199.5 to 205 mg/L, conductivity fluctuated between 399 and 411 microS/cm, and turbidity varied from 0.43 to 0.73 NTU. In the Tench area, the value of total chlorine ranged from 0.14 mg/L at Station # T-7 to 0.55 mg/L at Station # T-1. Total coliform varied from 3.6 to 5.1 MPN/100 mL and fecal coliform were detected at all the stations except at Station # T-1. TDS ranged from 201.4 to 257 mg/L, conductivity varied from 343 to 513 microS/cm, and turbidity ranged between 0.66 and 1.55 NTU. It is recommended to the respective agencies to ensure that the chlorine residual is available at consumer end.  相似文献   

4.
The impact of Attenda abattoir, Ogbomoso southwestern Nigeria on four water sources was investigated using geoelectrical imaging and microbiological analysis. 2D electrical resistivity imaging indicated groundwater contamination by leachate from the abattoir. Electrical resistivity values measured by the traverse run directly on the waste dump and other areas impacted by the waste from the abattoir are generally very low (6.68-16.7 ?m) in comparison to other positions (135-288 ?m). The total viable bacteria count of the water samples ranged from 0.49 × 10(6) to 2.85 × 10(8) cfu/ml and all samples are contaminated with coliforms with the most probable number (MPN)/100 ml ranging from 110 to ≥ 1,600 MPN/100 ml. Among bacteria isolated from the study site (n = 95), resistance to eight antibiotics ranged from 35.8% to 94%. In addition, 85% of Streptococcus agalactiae (n = 31) and Staphylococci (n = 9) showed haemolytic activity while 92% of all isolates showed β-lactamase activity. These results suggest that operations of the abattoir may impact negatively on surrounding aquatic ecosystem and endanger the health of surrounding residents who use water from the wells for domestic purposes. Furthermore, such aquatic ecosystems may serve as reservoir of antibiotic resistant bacteria.  相似文献   

5.
One thousand three-hundred and ninety-four drinking water sources comprising ground water, surface water and piped supplies were tested in order to compare the presence-absence (P-A) test with standard MPN method to detect coliforms as indicators of water quality. Out of 1394 samples, 1074 (77.04%) and 1030 (74.88%) were positive by the MPN and P-A test, respectively. The P-A test detected 96% of the positives detected by the MPN test. The P-A test may be effectively used as a rapid screening method to detect coliform contamination in less polluted sources such as ground water and piped supplies.  相似文献   

6.
A simple, sensitive, rapid, inexpensive paper strip impregnated with Salmonellal E. coli medium (SEM) was formulated, and placed in a test tube. When potable water of 10 ml was added to the test tube it detected the faecal contamination of water samples within 16-48 h when incubated at room temperature from 20 to 35 degrees C. The positive results were indicated when the medium turned black (hydrogen sulfide production) for the presence of Salmonella sp. and/or the formation of a red ring (free indole from tryptophan) when a few drops of Kovac's reagent was added for the presence of coliform bacteria (E. coli). More than 600 water samples were tested with the new test (SEM) and results showed 99% agreement with that of the standard most probable number (MPN) coliform test and also proved highly successful in the field when it was employed to detect both Salmonella and E. coli. Different water testing laboratories involved in a water quality monitoring programme and governmental agencies evaluated the test media and reported that the test was user friendly, reliable and simple to perform in the field and will be especially useful for screening of both urban and rural water supplies for routine monitoring of bacteriological contamination.  相似文献   

7.
Suspended sediment concentration (SSC) is generally determined from the direct measurement of sediment concentration of river or from sediment transport equations. Direct measurement is very costly and cannot be conducted for all river gauge stations. Therefore, correct estimation of suspended sediment amount carried by a river is very important in terms of water pollution, channel navigability, reservoir filling, fish habitat, river aesthetics and scientific interests. This study investigates the feasibility of using turbidity as a surrogate for SSC as in situ turbidity meters are being increasingly used to generate continuous records of SSC in rivers. For this reason, regression analysis (RA) and artificial neural networks (ANNs) were employed to estimate SSC based on in situ turbidity measurements. The SSC was firstly experimentally determined for the surface water samples collected from the six monitoring stations along the main branch of the stream Harsit, Eastern Black Sea Basin, Turkey. There were 144 data for each variable obtained on a fortnightly basis during March 2009 and February 2010. In the ANN method, the used data for training, testing and validation sets are 108, 24 and 12 of total 144 data, respectively. As the results of analyses, the smallest mean absolute error (MAE) and root mean square error (RMSE) values for validation set were obtained from the ANN method with 11.40 and 17.87, respectively. However these were 19.12 and 25.09 for RA. It was concluded that turbidity could be a surrogate for SSC in the streams, and the ANNs method used for the estimation of SSC provided acceptable results.  相似文献   

8.
In spite of the importance and popularity of swimming pools in summer, they have been identified as posing some public health risks to users due to either chemical or microbiological contamination. This study was carried out aiming at assessing the quality of water for some Alexandria's swimming pools in order to determine its compliance with the Egyptian standards no. 418/1995. Five swimming pools were selected randomly from different districts. Physical and chemical parameters, as well as biological examination of a total of 30 samples, were carried out using standard analytical methods. Water samples were collected from the studied swimming pools monthly over 6?months and pool water monitoring was carried out during afternoon of the weekends when the pools were most heavily used. The results indicated overall poor compliance with the standards. Compliance of the pool water to the microbial parameters, residual chlorine, pH, and turbidity were 56.7% (17 samples), 20% (6 samples), 46.7% (14 samples), and 46.7% (14 samples), respectively. Statistical analysis showed significant association between water contamination with microbial indicators and physical–chemical aspects such as residual chlorine, temperature, turbidity, and load of swimmers. Furthermore, Cryptosporidium oocysts and Giardia lamblia cysts has been found in 10% of samples. It was concluded that there is a need to improve disinfection and cleaning procedures, with consideration given to safety, and size of the pool in relation to bathing load. There is also a need to monitor swimming pool water quality continuously, and to increase bather hygienic practices and awareness of the risks as well as training of governmental inspectors.  相似文献   

9.
The origin and distribution of microbial contamination in Lake Geneva's most polluted bay were assessed using faecal indicator bacteria (FIB). The lake is used as drinking water, for recreation and fishing. During 1 year, water samples were taken at 23 points in the bay and three contamination sources: a wastewater treatment plant (WWTP), a river and a storm water outlet. Analyses included Escherichia coli, enterococci (ENT), total coliforms (TC), and heterotrophic plate counts (HPC). E. coli input flux rates from the WWTP can reach 2.5 x 10(10) CFU/s; those from the river are one to three orders of magnitude lower. Different pathogenic Salmonella serotypes were identified in water from these sources. FIB levels in the bay are highly variable. Results demonstrate that (1) the WWTP outlet at 30 m depth impacts near-surface water quality during holomixis in winter; (2) when the lake is stratified, the effluent water is generally trapped below the thermocline; (3) during major floods, upwelling across the thermocline may occur; (4) the river permanently contributes to contamination, mainly near the river mouth and during floods, when the storm water outlet contributes additionally; (5) the lowest FIB levels in the near-surface water occur during low-flow periods in the bathing season.  相似文献   

10.
同步荧光光谱法测定环境水样中的多环芳烃   总被引:1,自引:0,他引:1  
为了建立快速测定水体中多环芳烃的方法,用恒波长同步荧光法对14种多环芳烃混合标样进行了分析。在优化的实验条件下,对环境水样进行分析,可以鉴别出11种多环芳烃。14种PAHs在0~1000ng/ml范围内呈良好的线性关系,相关系数r均不小于0.9988,相对标准偏差(RSD)在1.06%~1.67%之间(n=6)。14种PAHs的检出限在0.072~3.9ng/ml之间。该方法应用于污水、样河水样、池塘水样中的多环芳烃检测取得了良好的效果,回收率分别为82.2%~111.0%、86.0%~107.0%、88.0%~106.2%(n=5)。  相似文献   

11.
An attempt has been made to develop water quality index (WQI), using six water quality parameters Dissolved oxygen (DO), Biochemical oxygen Demand (BOD), Most Probable Number (MPN), Turbidity, Total Dissolved Solids (TDS) and pH measured at eight different stations along the river basin. Rating curves were drawn based on the tolerance limits of inland waters and health point of view. Bhargava WQI method and Harmonic Mean WQI method were used to find overall WQI along the stretch of the river basin. Five point rating scale was used to classify water quality in each of the study areas. It was found that the water quality of Netravathi varied from Excellent to Marginal range by Bhargava WQI method and Excellent to Poor range by Harmonic Mean WQI method. It was observed that the impact of human activity was severe on most of the parameters. The MPN values exceeded the tolerable limits at almost all the stations. It was observed that the main cause of deterioration in water quality was due to the lack of proper sanitation, unprotected river sites and high anthropogenic activities.  相似文献   

12.
Faecal contamination is a major causative factor for incidence of water borne infectious diseases. Certain hydrogen sulfide (H2S) producing enteric bacteria such as Salmonella sp. and Citrobacter sp., assosiated with coliforms, have been considered for rapid detection of recent faecal contamination in water. The basic H2S test medium, modified by adding 0.25 gm/L of L-cystine HCl, was examined for its efficiency with 90 water samples collected from 40 pipe supplies, 20 open wells, 15 hand pumps and 15 different surface water bodies (river, streams and ponds). Sterilized modified culture medium in glass vials was inoculated with 100 mL of each sample and incubated at 20, 25, 30, 35 and 44 C for 18, 24, 42, 48, 66 and 72 h. Blackening of content in incubated vials was considered positive. For comparison, most probable number (MPN) of coliform and faecal coliform per 100 mL was also estimated in each sample by multiple tube fermentation (MTF) method. H2S positive result was exhibited by 78% of samples. Coliform (> 10) and faecal coliform/100 mL were also detected in 59% of samples. Maximum H2S positive results (100%) were found with well and surface water samples incubated at 30, 35 and 44 C for 18 h. Coliform (> 10) and faecal coliform/100 mL were also detected in most of these samples. Pipe supplies (60%) and hand pumps (73%) also exhibited considerable H2S production. Coliforms and faecal coliforms were also found in significant number of these samples. Thus, the modified H2S test may prove a useful alternative indicator of faecal contamination for water quality surveillance and screening of large number of water samples in short duration, particularly during any outbreak of water borne disease among rural population.  相似文献   

13.
研究了不同分析方法、去浊度手段和预处理方式对地表水总磷测定的影响。结果表明:钼酸铵分光光度法在跨界水体联合监测中较连续流动分析法、氯化亚锡还原光度法、孔雀绿-磷钼杂多酸分光光度法更为适用;在水样没有色度的情况下,采用浊度-色度补偿法和离心法都能有效消除浊度干扰,相对误差±10%;预处理方式的不同是导致各监测单位测定结果可比性差的最关键因素。  相似文献   

14.
The present study was undertaken to examine the drinking water quality of Rawal Treatment Plant, Rawalpindi and its distribution network by collecting samples from eight different locations. The aim was to determine potential relationship between the presence of microorganisms and chlorine residual in the distribution network. Quantification of chlorine residual, turbidity, standard plate count (SPC), fecal and total coliforms by Most Probable Number (MPN) was performed. Three different forms of chlorine were measured at each sampling station such as free chlorine, residual chlorine, chloramines and total chlorine residual. A critical evaluation of data presented indicated that pH generally ranged from 7.02–7.30; turbidity varied from 0.34–2.79 NTU; conductivity fluctuated from 359–374 μS/cm; and TDS values were found to be ranging between 180–187 mg/l. Station # 7 was found to be most contaminated. The value of total chlorine was found to be 0.86 to1.7 mg/l at Station # 3 and 6, respectively. Highest standard plate count was 62 CFU/ml at Station # 7. Total coliforms were less than 1.1 MPN/100 ml at almost most of the stations except at Station # 3 where it was found to be greater than 23.0 MPN /100 ml. Overall aim of this study is to create awareness about contamination of drinking water in the water distribution networks and to make recommendations to provincial agencies such as EPA, CDA and WASA that regular monitoring should be carried out to ensure that the chlorine residual is available at consumer end.  相似文献   

15.
对国标法( GB/T 5750.8-2006)中的二甲氨基苯甲醛分光光度法测定饮用水源水中水合肼进行了深入研究,同时指出了水合肼测定全过程中应注意的问题及解决方法.指出在标准分析方法基础上,选用合格的最新生产的分析纯以上的试剂,现场调节水样酸度至1 mol/L,正确进行浑浊带色干扰因素校正消除,利用氨基磺酸去除亚硝酸盐...  相似文献   

16.
The present paper reports a detailed study that is based on the monitoring of naproxen, ibuprofen, and diclofenac in Mbokodweni River and wastewater treatment plants (WWTPs) located around the city of Durban in KwaZulu-Natal Province of South Africa. Target compounds were extracted from water samples using a multi-template molecularly imprinted solid-phase extraction prior to separation and quantification on a high-performance liquid chromatography equipped with photo diode array detector. The analytical method yielded the detection limits of 0.15, 1.00, and 0.63 μg/L for naproxen, ibuprofen, and diclofenac, respectively. Solid-phase extraction method was evaluated for its performance using deionized water samples that were spiked with 5 and 50 μg/L of target compounds. Recoveries were greater than 80% for all target compounds with RSD values in the range of 4.1 to 10%. Target compounds were detected in most wastewater and river water samples with ibuprofen being the most frequently detected pharmaceutical. Maximum concentrations detected in river water for naproxen, ibuprofen, and diclofenac were 6.84, 19.2, and 9.69 μg/L, respectively. The concentrations of target compounds found in effluent and river water samples compared well with some studies. The analytical method employed in this work is fast, selective, sensitive, and affordable; therefore, it can be used routinely to evaluate the occurrence of acidic pharmaceuticals in South African water resources.  相似文献   

17.
Efficient management of deteriorating water bodies can be achieved by determining the sources of faecal pollution. Resourceful techniques for discrimination of the sources of Escherichia coli in surface water have recently been developed, including the use of river water to facilitate faecal indicator surveillance, identification of sources of faecal contamination and employing relevant management practices to maintain water quality. This study was conducted to employ microbial source tracking (MST) techniques for the determination of the sources of faecal pollution based on a water quality investigation of the physico-chemical characteristics and coliform count point of the Tirumanimuttar River. To accomplish this, an MST library-based antibiotic resistance analysis, serotyping and the genomic tool rep-PCR techniques were applied, and the obtained results were analysed statistically. Among 135 and 70 E. coli isolates present in the library and water samples collected from the river and nearby well water sources, respectively, most showed intrinsic, high or moderate resistance to antibiotics. Isolates from human and pig faecal sources were 92% homologous with the samples from the river, whereas isolates from sewage and dairy cattle showed 89% and 80% homology, respectively. These findings indicated that the Tirumanimuttar River is subjected to stress from anthropogenic activities and runoff contaminated with agricultural and human faecal contamination. The sources of faecal pollution identified in this study may facilitate the monitoring and management of the Tirumanimuttar River.  相似文献   

18.
水中丙烯酰胺气相色谱测定方法研究   总被引:2,自引:2,他引:0  
研究建立了大口径毛细管柱气相色谱法测定水中丙烯酰胺的方法。优化了水中丙烯酰胺的衍生化条件,用乙酸乙酯和正己烷混合溶剂萃取衍生产物,萃取后直接进行色谱分离分析,水中丙烯酰胺的最低检测浓度为0.05μg/L,回收率在94.5%~113%之间;进行6次平行精密度试验,相对标准偏差低于11.5%。研究建立的气相色谱法简便、快速、准确、重现性好,定量、定性准确可靠,适合水中丙烯酰胺的分析测定。  相似文献   

19.
Simple microbial test comprising H2S paper strip test,presence-absence (PA) test, and fluorogenic brila broth (BB)test performed directly at 44.5 °C were evaluated andcompared with the standard most probable number (MPN) method fordetection of fecal coliforms in 173 drinking water sources. BBand PA test were comparable with standard MPN method, whereas,poor compliance was noted for H2S test. PA test whencompared with standard MPN test only 15%; disagreement wasdetected, whereas, highest disagreement of 40%; was observed incase of H2S test. BB test was found to be highly sensitiveas only 7.8% disagreement with that of standard MPN test wasfound. Three hundred cultures obtained from positive tests wereidentified in order to evaluate the specificities of test usedin detection of fecal indicator Escherichia coli. BB testwas also found highly specific in detection of indicatororganism as compared to PA and H2S test. Among theorganisms isolated from BB test 84.4%; of them were identifiedas E. coli as compared to 43.4 and 33.3 in PA and H2Stest, respectively. The low incidence of recovery of E.coli (18.1%) for the standard MPN method places doubt on thevalidity of its application in tropical areas. The result ofthis investigation suggest that BB performed directly at 44.5 °C could be suitable cost effective test to assess themicrobiological quality of drinking water in India and other tropical countries.  相似文献   

20.
建立一种用离子色谱法同时分离测定被污染河流水中微量乙酸、丙酸和丁酸的方法。采用IonPac AS11-HC阴离子分离柱,5mM NaOH淋洗液,流速1.0ml/min。结果表明,乙酸、丙酸、丁酸的检出限按峰高计分别为0.258、0.294、0.374mg/L;按峰面积计分别为0.350、0.421、0.588mg/L。乙酸、丙酸、丁酸的保留时间、峰高、峰面积的变异系数RSD在0.03%~3.92%之间。对某河流水样分析,乙酸、丙酸、丁酸的回收率在99.6%~107.6%间。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号