首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Trichloroacetic acid (TCA) and dichloroacetic acid (DCA) are possible minor atmospheric degradation products of perchloroethylene and trichloroethylene, respectively. These acids may be wet- or dry-deposited from the atmosphere to land surfaces and hence possibly affect plant growth. However, the existing database on TCA levels in soil is limited to a few studies carried out in the late 1980's and the early to mid-1990's and it was concluded that there is a need for further measurements of concentrations of TCA and DCA in soils. In this study soil samples from 10 locations in 5 European countries, as well as vegetation samples, and a limited number of rainwater and air samples were collected and analysed for DCA and TCA to determine the concentrations of these compounds. An isotope dilution method using GC-MS was used for the determination of these acids in the samples. The method was briefly validated and the performance characteristics are presented. The results of the analysis of the soil samples show that the DCA and TCA concentrations in soil from different sites in Europe are more or less comparable, with the exception of Germany, especially Freudenstadt, where significantly higher TCA concentrations (up to 12 microg kg(-1) dw) were found. The average DCA and TCA concentrations in soil in this study were 0.25 +/- 0.12 and 0.64 +/- 1.40 microg kg(-1) dw, respectively. Generally, the concentration in soils from forest areas are about twice those from open-land areas. The DCA and TCA concentrations in vegetation samples ranged from 2.1 to 73 microg kg(-1) dw for DCA and from 4.7 to 17 microg kg(-1) dw for TCA. Thus, the concentrations in vegetation samples are 10-20 times higher than the soil concentrations. DCA and TCA concentrations in wet deposition samples and air samples collected in The Netherlands were 0.14 and 0.15 microg l(-1) for wet deposition samples and <0.5 and 0.7 ng m(-3) for air samples respectively. For these samples taken in The Netherlands, the estimated values for soil and air concentrations calculated from the wet deposition concentrations are in agreement with the concentrations measured in this study.  相似文献   

2.
Air samples were collected from 4 field sites in Europe: 2 sites from the UK, Hazelrigg (semi-rural) and Manchester (urban); 1 site from Ireland: Mace Head (rural); and 1 site from Norway: Kjeller (rural). Additionally, air samples were taken from indoor locations in Troms?, Norway. Air samples were collected using high-volume air samplers employing sampling modules containing glass-fibre filters (GFFs, particle phase), and glass columns with a polyurethane foam (PUF)-XAD-2-PUF sandwich (gaseous phase). Typical outdoor air volumes required for the determination of per- and polyfluorinated alkyl substances (PFAS) ranged from 500-1800 m3. GFFs and PUF-XAD columns were analysed separately to obtain information on phase partitioning. All air samples were analysed for volatile, neutral PFAS, with selected GFF samples halved for analysis of both neutral and airborne particle-bound ionic PFAS. Volatile PFAS were extracted from air samples by cold-column immersion with ethyl acetate, and were analysed by gas chromatography-mass spectrometry in the positive chemical ionisation mode (GC-PCI-MS). Ionic PFAS were extracted from GFFs by sonication in methanol, and were analysed by liquid chromatography-time-of-flight-mass spectrometry (LC-TOF-MS) using electrospray ionisation in the negative ion mode (ESI-). Perfluorooctanoate (PFOA) was often the predominant analyte found in the particulate phase at concentrations ranging from 1-818 pg m(-3), and 8:2 fluorotelomer alcohol (FTOH) and 6:2 FTOH were the prevailing analytes found in the gas phase, at 5-243 pg m(-3) and 5-189 pg m(-3), respectively. These three PFAS were ubiquitous in air samples. Many other PFAS, both neutral and ionic, were also present, and levels of individual analytes were in the 1-125 pg m(-3) range. Levels of some PFAS exceeded those of traditional persistent organic pollutants (POPs). In this study, the presence of 12:2 FTOH and fluorotelomer olefins (FTolefins), and ionic PFAS other than perfluorooctane sulfonate (PFOS) and PFOA, are reported in air samples for the first time. Concentrations of neutral PFAS were several orders of magnitude higher in indoor air than outdoor air, making homes a likely important diffuse source of PFAS to the atmosphere. Our repeated findings of non-volatile ionic PFAS in air samples raises the possibility that they might directly undergo significant atmospheric transport on particles away from source regions, and more atmospheric measurements of ionic PFAS are strongly recommended.  相似文献   

3.
During a monitoring campaign concentrations of volatile organic compounds (VOCs) were measured in indoor air of 79 dwellings where occupants had not complained about health problems or unpleasant odour. Parameters monitored were the individual concentration of 68 VOCs and the total concentration of all VOCs inside the room. VOCs adsorbed by Tenax TA were then analysed by means of thermal desorption, gas chromatography and mass spectrometry. The analytical procedure and quantification was done according to the recommendation of the ECA-IAQ Working Group 13 which gave a definition of the total volatile organic compound (TVOC) concentration. Using this recommendation TVOC-concentrations ranged between 33 and 1600 microg m(-3) with a median of 289 microg m(-3). Compounds found in every sample and with the highest concentrations were 2-propanol, alpha-pinene and toluene. Save for a few samples, all concentrations measured have been a factor 2 to 10 lower, compared to data from similar studies. Only a few terpenes and aldehydes were found exceeding published reference data or odour threshold concentrations. However, it has been found that sampling and analysing methods do have a considerable impact on the results, making direct comparisons of studies somewhat questionable. 47% of all samples revealed concentrations exceeding the threshold value of 300 microg TVOC m(-3) set by the German Federal Environmental Agency as a target for indoor air quality. Using the TVOC concentration as defined in the ECA-IAQ methodology is instrumental in assessing exposure to VOCs and identifying sources of VOCs. The background concentrations determined in this study can be used to discuss and interpret target values for individual and total volatile organic compounds in indoor air.  相似文献   

4.
Solid-phase microextraction (SPME) was studied for the measurement of volatile organic compounds (VOCs) in indoor air. An adsorptive PDMS/Carboxen fibre was used and an analytical methodology was developed in order to overcome competitive adsorption. Kinetics and adsorption isotherms were investigated for different sample volumes and model compounds. In order to evaluate competitive adsorption on the fibre, these compounds were studied alone and in mixture. From the results obtained, the operating conditions allowing co-adsorption of the target compounds were determined: the air sample is enclosed in a 250 mL glass bulb where the SPME fibre is exposed until adsorption equilibrium. This procedure was combined with GC/MS analysis for the identification and quantification of VOCs in indoor air. The performances were determined by using a standard gas containing 10 VOCs representative of indoor environments (acetaldehyde, acetone, BTX, alpha-pinene, trichloroethylene, alkanes). The detection limits were determined in single ion monitoring mode and for a signal to noise ratio of 3. Except acetaldehyde (6 microg m(-3)), they are all below 0.5 microg m(-3). Calibration curves are linear up to 10 micromol m(-3) for all the compounds with good correlation coefficients (above 0.99). The reproducibility ranges from 6 to 12% according to the compound. The methodology was then applied to the comparison of the VOCs content in classrooms of two different schools.  相似文献   

5.
In this paper we demonstrate the use of SPE cartridges for sampling of organophosphate triesters in indoor air by adsorptive enrichment. The method has been optimised for the sampling and analysis of organophosphate triesters using a 25 mg aminopropyl silica SPE cartridge. The same cartridge is used for the active air sampling as well as for the subsequent extraction and clean-up of the sample. This makes the method fast and eliminates some tedious and time-consuming manual sample handling steps. Sampling and extraction efficiency was high for the investigated organophosphates, and limit of detection was in the range 0.1-0.3 ng m(-3). The method was applied to measurements of organophosphate triesters in two lecture halls and an electronics dismantling facility, and was compared with results from common filter/adsorbent sampling at each site. Analysis was made by GC with selective detection by NPD set in phosphorus mode, and by GC-MS. Thirteen organophosphate triesters (not counting isomers) were detected in the electronic dismantling facility. Chlorinated organophosphate triesters were detected in all locations with concentrations over 1 microg m(-3) in the lecture halls. This kind of adsorptive enrichment using an SPE cartridge could be adjusted to other types of analytes as well.  相似文献   

6.
One hundred workers carried personal air sampling equipment during three days to assess exposure to inhalable and respirable Mn. A novel four-step chemical fractionation procedure developed for the speciation of Mn in workroom aerosols was applied for selected aerosol filters. Blood and urine samples were analysed for Mn. The geometric mean (GM) concentrations of inhalable (n = 265) and respirable (n = 167) Mn determined in all filters were 254 microg m(-3) and 28 microg m(-3) respectively. Only 10.6% (95% CI 8.9-12.5) respirable Mn was found in the inhalable fraction when inhalable and respirable samples collected in parallel were considered (n = 153 pairs). There was a high correlation (Pearson's r = 0.70; p < 0.001) between respirable and inhalable Mn. The largest amounts of Mn in the inhalable aerosol fraction were found as Mn0 and Mn2+ (47.4%), whereas 28% was practically "insoluble". The associations between B-Mn and aerosol concentrations of Mn were weak, but an association was found between U-Mn and respirable Mn; Pearson's r being 0.38 between "soluble" respirable Mn and U-Mn. No significant association was found between the "insoluble" components (probably SiMn) and Mn in biological samples.  相似文献   

7.
Total gaseous mercury was collected at ten sites, which comprise part of the UK rural heavy metals monitoring network, between 2005 and 2008. Using the gold amalgam technique to capture total gaseous mercury, samples were analysed using a Tekran 2537A mercury vapour analyser. The data showed no upward or downward trend in atmospheric mercury concentrations over the period, with 4 year average concentrations between 1.3 and 1.9 ng m(-3), which are in line with other studies' observed northern hemispheric background concentrations of between 1.5 and 1.7 ng m(-3). Using data from nine of the sites, we were able to show seasonality within the data and through kriging we were able to interpolate the TGM concentrations over the UK, revealing a south-east to north-west declining concentration gradient. Using continuous speciated mercury measurements from one of the network sites, we show through wind sector analysis and air-mass back trajectories that this spatial trend is likely to be due to air masses moving over the UK from continental Europe on easterly winds. The levels of TGM recorded in the south-east of the UK also more closely match observed background TGM levels on the continent, which could indicate that the TGM concentrations from the north of the UK are a better reflection of the true North Atlantic atmospheric mercury background level.  相似文献   

8.
An analytical method for ethylene glycol and propylene glycols has been developed for measuring airborne levels of these chemicals in non-occupational environments such as residences and office buildings. The analytes were collected on charcoal tubes, solvent extracted, and analyzed by gas chromatography-mass spectrometry using a positive chemical ionization technique. The method had a method detection limit of 0.07 microg m(-3) for ethylene glycol and 0.03 microg m(-3) for 1,2- and 1,3-propylene glycols, respectively, based on a 1.44 m3 sampling volume. Indoor air samples of several residential homes and other indoor environments have been analyzed. The median concentrations of ethylene glycol and 1,2-propylene glycol in nine residential indoor air samples were 53 microg m(-3) and 13 microg m(-3) respectively with maximum values of 223 microg m(-3) and 25 microg m(-3) detected for ethylene glycol and 1,2-propylene glycol respectively. The concentrations of these two chemicals in one office and two laboratories were at low microg m(-3) levels. The maximum concentration of 1,3-propylene glycol detected in indoor air was 0.1 microg m(-3).  相似文献   

9.
Infrared spectrometry is a versatile basis to analyse greenhouse gases in the atmosphere. A multicomponent air pollution software (MAPS) was developed for retrieval of gas concentrations from radiation emission as well as absorption measurements. Concentrations of CO, CH4, N2O, and H2O as well as CO2, NO, NO2, NH3, SO2, HCl, HCHO, and the temperature of warm gases are determined on-line. The analyses of greenhouse gases in gaseous emission sources and in ambient air are performed by a mobile remote sensing system using the double-pendulum interferometer K300 of the Munich company Kayser-Threde. Passive radiation measurements are performed to retrieve CO, N2O, and H2O as well as CO2, NO, SO2, and HCl concentrations in smoke stack effluents of thermal power plants and municipal incinerators and CO and H2O as well as CO2 and NO in exhausts of aircraft engines. Open-path radiation measurements are used to determine greenhouse gas concentrations at different ambient air conditions and greenhouse gas emission rates of diffusive sources as garbage deposits, open coal mining, stock farming together with additional compounds (e.g. NH3), and from road traffic together with HCHO. Some results of measurements are shown. A future task is the verification of emission cadastres by these inspection measurements.  相似文献   

10.
A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 microg m(-3) and 1248 microg m(-3) were determined to be 91.2 +/- 3.9 ml min(-1) and 111.6 +/- 2.8 ml min(-1), respectively. The acetic acid sampling rate was independent of the concentration in the range 160 microg m(-3)-1564 microg m(-3), and amounted to 97.3 +/- 3.1 ml min(-1). Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 3-21% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 +/- 0.07 microg for formic acid and 1.21 +/- 0.14 microg for acetic acid, and detection limits lower than 0.5 microg m(-3) could be achieved, which is an improvement of 98-99% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.  相似文献   

11.
The thermal degradation products of polyurethanes (PURs) and exposure to isocyanates were studied by stationary and personal measurements in five different occupational environments. Isocyanates were collected on glass fibre filters impregnated with 1-(2-methoxyphenyl)piperazine (2MP) and in impingers containing n-dibutylamine (DBA) in toluene. connected to a glass fibre postfilter. The derivatives formed were analysed by liquid chromatography: 2MP derivatives with UV and electrochemical detection and DBA derivatives with mass spectrometric detection. The release of aldehydes and other volatile organic compounds into the air was also studied. In a comparison of the two sampling methods, the 2MP method yielded about 20% lower concentrations for 4,4'-methylenediphenyl diisocyanate (MDI) than did the DBA method. In car repair shops, the median concentration of diisocyanates (given as NCO groups) in the breathing zone was 1.1 microg NCO m(-3) during grinding and 0.3 microg NCO m(-3) during welding, with highest concentrations of 1.7 and 16 pg NCO m(-3), respectively. High concentrations of MDI, up to 25 and 19 microg NCO m(-3), respectively, were also measured in the breathing zone during welding of district heating pipes and turning of a PUR-coated metal cylinder. During installation of PUR-coated floor covering, small amounts of aliphatic diisocyanates were detected in the air. A small-molecular monoisocyanate, methyl isocyanate, and isocyanic acid were detected only during welding and turning operations. The diisocyanate concentrations were in general higher near the emission source than in the workers' breathing zone. A sampling strategy to evaluate the risk of exposure to isocyanates is presented.  相似文献   

12.
Eleven organophosphorus compounds (OPs) that are used as plasticizers and flame retardants were analysed in duplicate samples of indoor air from 17 domestic and occupational environments. Solid-phase extraction (SPE) columns were used as adsorbents and analysis was performed using GC with a nitrogen phosphorus selective detector. The total amounts of OPs in the air samples ranged between 36 and 950 ng m(-3); tris(chloropropyl) phosphate (TCPP) and tris(2-chloroethyl) phosphate (TCEP) being the most abundant (0.4 to 730 ng m(-3)), followed by tributyl phosphate (0.5-120 ng m(-3)). Public buildings tended to have about 3-4 times higher levels of OPs than domestic buildings. The relative amounts of individual OPs varied between the sites and generally reflected the building materials, furniture and consumer products used in the sampled environments. Potential sources of these compounds include, inter alia, acoustic ceilings, upholstered furniture, wall coverings, floor polish and polyvinylchloride floor coverings. A correlation was observed between the TCEP concentrations in the air in the sampled environments and previously reported concentrations in dust, but no such correlation was seen for the heavier and less volatile tris(2-butoxyethyl) phosphate (TBEP). Based on estimated amounts of indoor air inhaled and dust ingested, adults and children in the sampled environments would be exposed to up to 5.8 microg kg(-1) day(-1) and 57 microg kg(-1) day(-1) total OPs, respectively.  相似文献   

13.
Total suspended particulate (TSP), PM(2.5) and BTEX were collected in nine offices in the province of Antwerp, Belgium. Both indoor and outdoor aerosol samples were analysed for their weight, elemental composition, and water-soluble fraction. Indoor TSP and PM(2.5) concentrations ranged from 7-31 microg m(-3) and 5-28 microg m(-3), with an average of 18 and 11 microg m(-3), respectively. Of all the elements analysed in indoor TSP, more than 95% was represented by Al, Si, K, Ca, Fe, Cl and S, accounting for 12% of the TSP by mass. The other elements showed significant enrichment relative to the earth's crust. The water-soluble ionic fraction accounted for almost 30% of the sampled indoor TSP by weight, and was enriched by anthropogenic activities. It was shown that the indoor PM levels varied among the offices, depending on the ventilation pattern, location, and occupation density of the office. Indoor BTEX levels ranged together from 5-47 microg m(-3) and were considerably higher than the corresponding outdoor levels. It was observed that some recently constructed and renovated buildings were clearly burdened with elevated levels for toluene, ethyl benzene, and xylenes, while outdoor air was found to be the main source for BTEX levels at the 'older' offices.  相似文献   

14.
Ambient ammonia concentrations, mainly originating from agricultural activities, have increased in the last few decades in Europe. As a consequence, critical loads on oligotrophic ecosystems such as forests and mires are greatly exceeded. Monitoring of ambient ammonia concentrations is necessary in order to investigate source-receptor relationships. Measuring ambient ammonia concentrations continuously with high time resolution is very expensive and cost-efficient systems are required. Where time resolution is of minor importance, several cost-effective systems, mainly dry denuder and passive samplers, can be applied. In this paper the Zürcher passive sampler, a diffusive sampling system, is presented. It is a Palmes type sampler with an acidic solution as absorbent and is easy to handle. It was tested at 46 sites in Switzerland over one year. The average concentration in ambient air was 2.5 microg m(-3) +/- 0.4 microg m(-3). The average of the blank values were 0.21 microg m(-3). The detection limit (double the standard deviation of the blank values) was 0.36 microg m(-3). Three passive samplers were exposed at each site and each period. The mean standard deviation of these triplicate measurements was 9.5%. Compared with a discontinuous tubular denuder system and a continuous annular denuder system, the deviation was less than 10%. The Zürcher passive sampler is a useful and cost-efficient tool to determine long-term average ammonia concentrations (one- to four-week periods) in ambient air for mean concentrations above 1 microg m(-3).  相似文献   

15.
Lead is a purely toxic heavy metal which induces a wide variety of adverse physiologic effects. Nevertheless, it has been mined and used for more than 8,000 years. Among the different contemporary sources of lead pollution, traffic-induced emissions from the combustion of leaded gasoline is of particular concern, as it can constitute more than 90 percent of total lead emissions into the atmosphere in congested urban areas where no phase-out activities have been adopted. Gasoline lead content and traffic volume are strongly correlated with concentrations of lead in various environmental media. In the absence of policies to reduce the use of lead in gasoline or to favor the use of unleaded gasoline, leaded gasoline remains the predominant grade in many countries. This paper assesses the status of lead pollution from the combustion of leaded gasoline in Beirut based on field measurements of lead in air and roadside dust of urban and rural/suburban areas and recent data on soil and blood lead levels. Average atmospheric lead concentrations was about 1.86 microg m(-3) at urban locations and 0.147 microg m(-3) at suburban locations. The analysis of roadside dust revealed an average lead level of 353 microg g(-1) along urban streets and 125 microg g(-1) along rural/suburban roads. Blood lead levels were also relatively high in comparison to countries where leaded gasoline has been phased-out.  相似文献   

16.
The release of radioactivity into the atmosphere from the damaged Fukushima Daiichi nuclear power plant started on March 12th, 2011. Among the various radionuclides released, iodine -131 ((131)I) and cesium isotopes ((137)Cs and (134)Cs) were transported across the Pacific Ocean and reached the United States on 17-18 March 2011. Consequently, an elevated level of fission products (131)I, (132)I, (132)Te, (134)Cs and (137)Cs were detected in air, water, and milk samples collected across the United States between March 17 and April 4, 2011. The continuous monitoring of activities over a period of 25 days and spatial variations across more than 100 sampling locations in the United States made it possible to characterize the contaminated air masses. For the entire period, the highest detected activity values ranged from less than 1 m Bq m(-3) to 31 m Bq m(-3) for the particulate (131)I, and up to 96 m Bq m(-3) for the gaseous (131)I fraction.  相似文献   

17.
2-Ethyl-1-hexanol is a possibly causative chemical in sick building symptoms, although 2-ethyl-1-hexanol has received little attention as a hazardous substance in studies on indoor air pollution. Airborne 2-ethyl-1-hexanol concentrations were measured from 2002 to 2004 in 99 rooms of 42 non-domestic buildings in Nagoya, Japan. The diffusive sampling method is effective for the measurement of a low level of 2-ethyl-1-hexanol in indoor air. The geometric mean (geometric standard deviation) of 2-ethyl-1-hexanol concentrations was 16.5 (5.4) microg m(-3) in indoor air and 1.9 (2.2) microg m(-3) in outdoor air. The maximum concentration of 2-ethyl-1-hexanol in indoor air and outdoor air was 2709 microg m(-3) and 12.4 microg m(-3), respectively. Fewer rooms in a small number of new buildings showed high concentrations of 2-ethyl-1-hexanol, while low concentrations were observed in many rooms of these buildings as well as the other new buildings. The room-to-room concentrations of 2-ethyl-1-hexanol in each building exhibited a wide variation. The geometric mean of the 2-ethyl-1-hexanol concentrations was significantly higher for indoor air than for outdoor air (p < 0.01). The correlation of the 2-ethyl-1-hexanol concentrations between indoor and outdoor air was not significant. Mechanical ventilation was effective in the temporary reduction of indoor 2-ethyl-1-hexanol level. These results suggest that the predominant source of 2-ethyl-1-hexanol was indoor areas.  相似文献   

18.
Atmospheric trace phthalic esters (PAEs) carried by total suspended particulates were systematically investigated. A total of 450 air samples were collected at six typical locations and three specific micro-environmental sites (a stadium with a new plastic track, new cars, and a farming greenhouse with plastic film) in Nanjing metropolitan area of China from April 2009 to January 2010. The samples were analyzed by high-performance liquid chromatography and ultraviolet detection. The results are summarized as follows: (1) The dominant PAEs are dimethyl phthalate (DMP), dibutyl phthalate (DBP), and diethylhexyl phthalate (DEHP), which were found in the atmosphere of Nanjing. The average concentrations of DMP, DBP, and DEHP were 10.5?±?1.2, 62.3?±?4.5, and 33.3?±?2.5?ng?m(-3), respectively, constituting 9.9%, 58.7%, and 31.4% of total PAEs (106?±?8.2?ng?m(-3)). (2) The dynamic variations of atmospheric PAEs in the three specific micro-environmental sites showed that the PAE concentrations in the stadium with a new plastic track reduced to normal after 1?month remediation, while new cars need 6?months to remove their effect. The levels of PAEs in a farming greenhouse with plastic film were relatively high, but little PAEs accumulated in vegetables. (3) The vertical profiles from 1.5 to 40?m above ground display some fluctuations in PAE concentration, but no significant height dependence. This information will make a valuable contribution to the examination of the influence of atmospheric PAEs on the environment and human health.  相似文献   

19.
In a cross-sectional study, 96 welders were compared with 96 control subjects. Also 27 former welders, all diagnosed as having manganism, were examined. Exposure to welding fumes was determined in the 96 welders, while the concentration of elements in whole blood and urine was determined in all subjects. The geometric mean (GM) concentrations of manganese (Mn) and iron in the workroom air were 97 microg m(-3) (range 3-4620 microg m(-3); n=188) and 894 microg m(-3) (range 106-20 300 microg m(-3); n=188), respectively. Thus the Mn concentration in the workroom air was on average 10.6% (GM) of that of the Fe concentration. No substantial difference was observed in the air Mn concentrations when welding mild steel as compared to welding stainless steel. The arithmetic mean (AM) concentration of Mn in whole blood (B-Mn) was about 25% higher in the welders compared to the controls (8.6 vs. 6.9 microg l(-1); p < 0.001), while the difference in the urinary Mn concentrations did not attain statistical significance. A Pearson's correlation coefficient of 0.31 (p < 0.01) was calculated between B-Mn and Mn in the workroom air that was collected the day before blood sampling. Although the exposure to welding fumes in the patients had ceased on average 5.8 years prior to the study (range 4 years-7 years), their AM B-Mn concentration was still higher than in referents of similar age (8.7 microg l(-1) vs. 7.0 microg l(-1)). However, their urinary concentrations of cobolt, iron and Mn were all statistically significantly lower.  相似文献   

20.
Manual and automatic welding machines (which use leaded alloys) are considered to be important sources of the emission of lead fumes into the general air of the working environment. Three workplaces at a television factory were selected for the present study, to determine the control class of the working unit. The concentrations of conventional measurements ("A" sampling points) were lower than the administrative control level (statutory standard of lead, 150 microg m(-3)), whereas the maximum concentration of 264.1 microg m(-3) ("B" sampling point) was higher at one working unit than the administrative control level. However, the control classes varied between class III (bad) and class I (good).  相似文献   