首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Levels of pollutants including PM2.5 and PM2.5 composition (black carbon and water soluble ions), SO(2), NO(2), CO, CO(2), and BTEX (benzene, toluene, ethylbenzene, xylene) were monitored for indoor and outdoor air at a university campus and a shopping center, both located in the Northern suburb of Bangkok. Sampling was done during December 2005-February 2006 on both weekdays and weekends. At the university, indoor monitoring was done in two different air conditioned classrooms which shows the I/O ratios for all pollutants to be below 0.5-0.8 during the weekends. However, on weekdays the ratios for CO(2) and most detected BTEX were above 1.0. The concept of classroom occupancy was defined using a function of the student number in a lecture hour and the number of lecture hours per day. Classroom 2, which had a higher occupancy than classroom 1, was characterized by higher concentrations of most pollutants. PM2.5 was an exception and was higher in classroom 1 (37 microg/m(3), weekdays) as compared to classroom 2 (26 microg/m(3), weekdays) which was likely linked to the dust resuspension from the carpeted floor in the former. Monitoring was also done in the shopping mall at three different sites. Indoor pollutants levels and the I/O ratios at the shopping mall were higher than at the university. Levels of all pollutants measured at the car park, except for toluene and CO(2), were the highest. I/O ratios of the pollutants at the mall were above 1.0, which indicates the relatively higher influence of the indoor sources. However, the black carbon content in PM2.5 outdoor is higher than indoor, which suggest the important contribution from outdoor combustion sources such as the traffic. Major sources of outdoor air pollution in the areas were briefly discussed. Exposure modeling was applied using the time activity and measured pollutant concentrations to assess the exposure of different groups of people in the study areas. High exposure to PM2.5, especially for the people working in the mall, should be of health effect concern.  相似文献   

2.
Indoor and outdoor measurements of nitrous acid and nitrogen dioxide were conducted at four homes and two offices in residential areas in Greater Cairo during winter (2000-2001) and summer (2001) seasons. Indoor nitrogen dioxide concentrations were higher than outdoor levels at the four homes, whereas indoor concentrations of nitrogen dioxide were lower than outdoor levels at the two offices, during both seasons. Indoor nitrous acid concentrations were higher than outdoor levels at all homes and offices during the period of study. The mean indoor nitrous acid concentrations were 6.8 ppb and 3.67 ppb in the four homes, whereas they were 1.42 ppb and 1.24 ppb in the two offices, during the winter and summer seasons, respectively. Indoor/outdoor ratios of nitrous acid concentration were 6.94 in the winter and 5.03 in the summer for all of the homes. However, the ratios were 1.31 and 1.61 during the winter and summer seasons, respectively, for the two offices. Insignificant positive correlation coefficients were found between indoor and outdoor concentrations of nitrous acid at homes and offices. The maximum outdoor nitrous acid concentrations were recorded during the winter season. Significant positive correlation coefficients were found between nitrous acid and nitrogen dioxide and relative humidity in homes and offices. The ratios of nitrous acid to nitrogen dioxide concentrations ranged from 0.045 to 0.16, with a mean of 0.1, in the four homes, whereas the ratios ranged from 0.026 to 0.09, with a mean of 0.059, in the two offices.  相似文献   

3.
The concentrations of total suspended particulate matter (TSP) and particulate matter less than 10 microns (PM10) were measured at various locations in a Jawaharlal Nehru port and surrounding harbour region. Meteorological data was also collected to establish the correlation with air pollutant concentration. The results are analysed from the standpoint of monthly and seasonal variations, annual trends as well as meteorological effects. The monthly mean concentration of TSP was in the range of 88.2 to 199.3 microg m(-3). The maximum and minimum-recorded value of PM10 was 135.8 and 20.3 microg m(-3), respectively. The annual average concentration of PM10 was 66.1 microg m(-3). There are clear associations between TSP and PM10 data set at all the measured three sites with a correlation coefficient of 0.89, 0.69 and 0.81, respectively. PM10 data appears to be a constant fraction of the TSP data throughout the year, indicating common influences of meteorology and sources. Particle size analysis showed PM10 to be 47% of the total TSP concentration, which is lower than reported for industrial area and traffic junctions in Mumbai. Anthropogenic sources contribute significantly to the PM10 fraction in an industrial region, while contributions from natural sources are more in a port and harbour area. Statistical analysis of air quality data shows that TSP is strongly correlated with wind speed but weakly correlated with temperature. There appears to be a simple inverse relationship between TSP and wind speed data, indicating the dilution and transport by winds.  相似文献   

4.
The relationship between indoor and outdoor particulate air pollution was investigated at an urban background site on the Payambar Azam Campus of Mazandaran University of Medical Sciences in Sari, Northern Iran. The concentration of particulate matter sized with a diameter less than 1 μm (PM1.0), 2.5 μm (PM2.5), and 10 μm (PM10) was evaluated at 5 outdoor and 12 indoor locations. Indoor sites included classrooms, corridors, and office sites in four university buildings. Outdoor PM concentrations were characterized at five locations around the university campus. Indoor and outdoor PM measurements (1-min resolution) were conducted in parallel during weekday mornings and afternoons. No difference found between indoor PM10 (50.1 ± 32.1 μg/m3) and outdoor PM10 concentrations (46.5 ± 26.0 μg/m3), indoor PM2.5 (22.6 ± 17.4 μg/m3) and outdoor PM2.5 concentration (22.2 ± 15.4 μg/m3), or indoor PM1.0 (14.5 ± 13.4 μg/m3) and outdoor mean PM1.0 concentrations (14.2 ± 12.3 μg/m3). Despite these similar concentrations, no correlations were found between outdoor and indoor PM levels. The present findings are not only of importance for the potential health effects of particulate air pollution on people who spend their daytime over a period of several hours in closed and confined spaces located at a university campus but also can inform regulatory about the improvement of indoor air quality, especially in developing countries.  相似文献   

5.
Endotoxin is a toxic, pro-inflammatory compound that has been detected in indoor air and dust in homes and occupational settings, and also in outdoor air. Data on the outdoor sampling of endotoxin are limited. Currently, little is known about the seasonal variation and influence of temperature on outdoor endotoxin levels. In the present study, we report endotoxin levels in fine fraction particulate matter with a 50% aerodynamic cutoff diameter of 2.5 microm (PM2.5) and describe the seasonal variation of endotoxin in Munich, Germany. In 1999-2000, PM2.5 was collected at forty outdoor monitoring sites across Munich. Approximately four samples were collected at each site for a total of 158 samples. Endotoxin concentrations in the PM2.5 samples were determined using the kinetic chromogenic Limulus Amebocyte Lysate (LAL) assay. The geometric mean endotoxin concentration was 1.07 EU mg PM2.5(-1) (95% C.I.: 0.915-1.251) or 0.015 EU m(-3) of sampled air (95% C.I.: 0.013-0.018). Munich endotoxin levels were significantly related to ambient temperature (p < 0.0001) and percent relative humidity (p < 0.0001). Sampling periods with higher average temperatures yielded higher levels of endotoxin in PM2.5 (r = 0.641), whereas decreases in percent relative humidity were associated with increased endotoxin levels in PM2.5 (r = -0.388). Endotoxin levels were significantly higher during the warmer seasons of spring [means ratio (MR): 2.5-2.7] and summer (MR: 2.1-3.0) than during winter. Although temperature and relative humidity do not explain all of the variability in endotoxin levels, their effects were significant in our data set. Temperature effects and seasonal variation of endotoxin should be considered in future studies of outdoor endotoxin.  相似文献   

6.
Fine particles (PM2.5) were sampled indoors and outdoors at 40 sampling sites; in ten classrooms in five schools, at ten preschools and 20 non-smoking homes, in three communities in Stockholm, Sweden, during nine 2-week periods. Each sampling site was sampled twice, once during winter and once during spring. The samples were analysed for elemental concentrations using X-ray fluorescence (XRF) spectroscopy. In all locations significantly higher outdoor concentrations were found for elements that are related to long-range transported air masses (S, Ni, Br and Pb), while only Ti was higher indoors in all locations. Similar differences for S, Br and Pb were found in both seasons for homes and schools. In preschools different seasonal patterns were seen for the long-range transported elements S, Br and Pb and the crustal elements Ti, Mn and Fe. The indoor/outdoor ratios for S and Pb suggest an outdoor PM2.5 particle net infiltration of about 0.6 in these buildings. The community located 25 km from the city centre had significantly lower outdoor concentrations of elements of crustal or traffic origin compared with the two central communities, but had similar levels of long-range transported elements. Significant correlations were found between PM2.5 and most elements outdoors (rs = 0.45-0.90). Copper levels were found to correlate well (rs = 0.64-0.91) to the traffic marker NO2 during both winter and spring in all locations. Copper may be a suitable elemental marker for traffic-related aerosols in health studies in areas without other significant outdoor Cu sources.  相似文献   

7.
This complex study presents indoor and outdoor levels of air-borne fine particles, particle-bound PAHs and VOCs at two urban locations in the city of Kaunas, Lithuania, and considers possible sources of pollution. Two sampling campaigns were performed in January-February and March-April 2009. The mean outdoor PM(2.5) concentration at Location 1 in winter was 34.5 ± 15.2 μg m(-3) while in spring it was 24.7 ± 12.2 μg m(-3); at Location 2 the corresponding values were 36.7 ± 21.7 and 22.4 ± 19.4 μg m(-3), respectively. In general there was little difference between the PM concentrations at Locations 1 and 2. PM(2.5) concentrations were lower during the spring sampling campaign. These PM concentrations were similar to those in many other European cities; however, the levels of most PAHs analysed were notably higher. The mean sum PAH concentrations at Locations 1 and 2 in the winter campaign were 75.1 ± 32.7 and 32.7 ± 11.8 ng m(-3), respectively. These differences are greater than expected from the difference in traffic intensity at the two sites, suggesting that there is another significant source of PAH emissions at Location 1 in addition to the traffic. The low observed indoor/outdoor (I/O) ratios indicate that PAH emissions at the locations studied arise primarily from outdoor sources. The buildings at both locations have old windows with wooden frames that are fairly permissive in terms of air circulation. VOC concentrations were mostly low and comparable to those reported from Sweden. The mean outdoor concentrations of VOC's were: 0.7 ± 0.2, 3.0 ± 0.8, 0.5 ± 0.2, 3.5 ± 0.3, and 0.2 ± 0.1 μg m(-3), for benzene, toluene, ethylbenzene, sum of m-, p-, o-xylenes, and naphthalene, respectively. Higher concentrations of VOCs were observed during the winter campaign, possibly due to slower dispersion, slower chemical transformations and/or the lengthy "cold start" period required by vehicles in the wintertime. A trajectory analysis showed that air masses coming from Eastern Europe carried significantly higher levels of PM(2.5) compared to masses from other regions, but the PAHs within the PM(2.5) are of local origin. It has been suggested that street dust, widely used for winter sanding activities in Eastern and Central European countries, may act not only as a source of PM, but also as source of particle-bound PAHs. Other potential sources include vehicle exhaust, domestic heating and long-range transport.  相似文献   

8.
The use of hydrated magnesium carbonate hydroxide (magnesia alba) for drying the hands is a strong source for particulate matter in indoor climbing halls. Particle mass concentrations (PM10, PM2.5 and PM1) were measured with an optical particle counter in 9 indoor climbing halls and in 5 sports halls. Mean values for PM10 in indoor climbing halls are generally on the order of 200-500 microg m(-3). For periods of high activity, which last for several hours, PM10 values between 1000 and 4000 microg m(-3) were observed. PM(2.5) is on the order of 30-100 microg m(-3) and reaches values up to 500 microg m(-3), if many users are present. In sports halls, the mass concentrations are usually much lower (PM10 < 100 microg m(-3), PM2.5 < or = 20 microg m(-3)). However, for apparatus gymnastics (a sport in which magnesia alba is also used) similar dust concentrations as for indoor climbing were observed. The size distribution and the total particle number concentration (3.7 nm-10 microm electrical mobility diameter) were determined in one climbing hall by an electrical aerosol spectrometer. The highest number concentrations were between 8000 and 12 000 cm(-3), indicating that the use of magnesia alba is no strong source for ultrafine particles. Scanning electron microscopy and energy-dispersive X-ray microanalysis revealed that virtually all particles are hydrated magnesium carbonate hydroxide. In-situ experiments in an environmental scanning electron microscope showed that the particles do not dissolve at relative humidities up to 100%. Thus, it is concluded that solid particles of magnesia alba are airborne and have the potential to deposit in the human respiratory tract. The particle mass concentrations in indoor climbing halls are much higher than those reported for schools and reach, in many cases, levels which are observed for industrial occupations. The observed dust concentrations are below the current occupational exposure limits in Germany of 3 and 10 mg m(-3) for respirable and inhalable dust. However, the dust concentrations exceed the German guide lines for work places without use of hazardous substances. In addition, minimizing dust concentrations to technologically feasible values is required by the current German legislation. Therefore, substantial reduction of the dust concentration is required.  相似文献   

9.
Total suspended particulates (TSP) were collected with a high volume sampler from the indoor work environment of 23 industries in Al-Rusayl Industrial Estate in Muscat, Oman. The values measured ranged from 39 microg m(-3) to 1033 microg m(-3). TSP in the ambient air of the area was found to have an average value of 1802 microg m(-3). TSP were analyzed for Pb, Cu, Ni, Zn and Cr. Compared to other metals, Pb emission was high with values ranging from 3 to 15 109 ng m(-3) with the mean value being 1 293 ng m(-3); Cu concentration varied from 3 to 2600 ng m(-3) with a mean value of 131 ng m(-3); Ni concentration ranged from 6 to 46 ng m(-3) with a mean value of 17 ng m(-3); Cr concentration ranged from 1 to 133 ng m(-3) with a mean value of 23 ng m(-3) while that of Zn varied from 0.01 to 1 978 ng m(-3) with the mean value being 464 ng m(-3). The concentrations of Pb, Ni, Cu, Cr, and Zn in the ambient air were also measured and found to have the following values: 122, 18, 16, 5 and 0.01 ng m(-3), respectively. These values indicate that the industries in the area do not contribute significantly to heavy metal air pollution.  相似文献   

10.
An analytical method for ethylene glycol and propylene glycols has been developed for measuring airborne levels of these chemicals in non-occupational environments such as residences and office buildings. The analytes were collected on charcoal tubes, solvent extracted, and analyzed by gas chromatography-mass spectrometry using a positive chemical ionization technique. The method had a method detection limit of 0.07 microg m(-3) for ethylene glycol and 0.03 microg m(-3) for 1,2- and 1,3-propylene glycols, respectively, based on a 1.44 m3 sampling volume. Indoor air samples of several residential homes and other indoor environments have been analyzed. The median concentrations of ethylene glycol and 1,2-propylene glycol in nine residential indoor air samples were 53 microg m(-3) and 13 microg m(-3) respectively with maximum values of 223 microg m(-3) and 25 microg m(-3) detected for ethylene glycol and 1,2-propylene glycol respectively. The concentrations of these two chemicals in one office and two laboratories were at low microg m(-3) levels. The maximum concentration of 1,3-propylene glycol detected in indoor air was 0.1 microg m(-3).  相似文献   

11.
This study measures the effect of emissions from an airport on the air quality of surrounding neighborhoods. The ambient concentrations of benzene, toluene, ethylbenzene, and o-, m-, and p-xylene (BTEX) were measured using passive samplers at 15 households located close to the airport (indoor, outdoor, and personal), at the end of airport runways and an out-of-neighborhood location. Measurements occurred over a 48-h period during summer 2006 and winter 2006?C2007. The average concentrations were 0.84, 3.21, 0.30, 0.99, and 0.34 ??g/m3 at the airport runways and 0.84, 3.76, 0.39, 1.22, and 0.39 ??g/m3 in the neighborhood for benzene, toluene, ethylbenzene, m-, p-, and o-xylene. The average neighborhood concentrations were not significantly different to those measured at the airport runways and were higher than the out-of-neighborhood location (0.48, 1.09, 0.15, 0.78, and 0.43 ??g/m3, each BTEX). B/T ratios were used as a tracer for emission sources and the average B/T ratio at the airport and outdoors were 0.20 and 0.23 for the summer and 0.40 and 0.42 for the winter, suggesting that both areas are affected by the same emission source. Personal exposure was closely related to levels in the indoor environment where subjects spent most of their time. Indoor/outdoor (I/O) ratios for BTEX ranged from 1.13 to 2.60 and 1.41 to 3.02 for summer and winter. The seasonal differences in I/O ratios reflected residential ventilation patterns, resulting in increased indoor concentrations of volatile organic compounds during winter.  相似文献   

12.
13.
贵阳室内氡时空分布特征研究   总被引:1,自引:0,他引:1  
为了全面分析室内氡的时空分布特征、来源和影响因素,选择了贵阳市不同地理位置的居民住宅、办公场所和公共场所,进行了为期一年的室内氡监测。贵阳市室内氡的平均浓度为(72.7±1.6)Bq/m3,低于室内空气污染国家标准,达标率98.5%。其中居民住宅、办公场所和公共场所的室内氡浓度分别为(93.46±86.93)、(74.68±40.74)、(61±26.93)Bq/m3。研究表明,室内涂料、装修程度和通风效果、小区环境等对室内氡浓度高低有显著影响,室内氡也随季节变化而发生波动。对于居民住宅和公共场所氡的室内外来源相对重要性不同。居民住宅内新楼和旧楼不同楼层室内氡的来源、影响因素和分布特征有显著差异。  相似文献   

14.
Food cooking using liquefied petroleum gas (LPG) has received considerable attention in recent years since it is an important source of particulate air pollution in indoor environments for non-smokers. Exposure to organic compounds such as polycyclic aromatic hydrocarbons (PAHs) contained in particles is of particular health concern since some of these compounds are suspected carcinogens. It is therefore necessary to chemically characterize the airborne particles emitted from gas cooking to assess their possible health impacts. In this work, the levels of fine particulate matter (PM(2.5)) and 16 priority PAHs were determined in three different ethnic commercial kitchens, specifically Chinese, Malay and Indian food stalls, where distinctive cooking methods were employed. The mass concentrations of PM(2.5) and PAHs, and the fraction of PAHs in PM(2.5) were the highest at the Malay stall (245.3 microg m(-3), 609.0 ng m(-3), and 0.25%, respectively), followed by the Chinese stall (201.6 microg m(-3), 141.0 ng m(-3), and 0.07%), and the Indian stall (186.9 microg m(-3), 37.9 ng m(-3), and 0.02%). This difference in the levels of particulate pollution among the three stalls may be attributed to the different cooking methods employed at the food stalls, the amount of food cooked, and the cooking time, although the most sensitive parameter appears to be the predominant cooking method used. Frying processes, especially deep-frying, produce more air pollutants, possibly due to the high oil temperatures used in such operations. Furthermore, it is found that frying, be it deep-frying at the Malay stall or stir-frying at the Chinese stall, gave rise to an abundance of higher molecular weight PAHs such as benzo[b]fluoranthene, indeno[1,2,3-cd]pyrene and benzo[g,h,i]perylene whereas low-temperature cooking, such as simmering at the Indian stall, has a higher concentration of lower molecular weight PAHs. In addition, the correlation matrices and diagnostic ratios of PAHs were calculated to determine the markers of gas cooking. To evaluate the potential health threat due to inhalation exposure from the indoor particulate pollution, excess lifetime cancer risk (ELCR) was also calculated for an exposed individual. The findings suggest that cooking fumes in the three commercial kitchens pose adverse health effects.  相似文献   

15.
宁波和温州地区夏季大气中不同粒径颗粒物特征分析   总被引:1,自引:0,他引:1  
对宁波地区北仑和奉化站、温州地区乐清站3个监测点夏季TSP、PM10、PM2.5和PM1.0进行监测,测试分析各种粒径颗粒物浓度水平和粒径分布特征,并通过化学质量平衡(CMB)受体模型对颗粒物进行源解析。监测结果显示,夏季宁波、温州地区TSP和PM10日均浓度为0.049~0.134mg/m3和0.025~0.084mg/m3,均未超过我国环境空气质量二级标准;PM2.5日均浓度为0.007~0.069mg/m3,按美国2006年EPA最新标准限值0.035mg/m3衡量,奉化、乐清、北仑站的超标天数占总监测天数的比例分别为75%、40%和37.5%。粒径分布统计结果显示,3个监测站点PM10占TSP的比例为48.78%~86.96%;PM2.5占TSP的比例为33.33%~72.46%;奉化和乐清监测点PM10中PM2.5和PM1.0的比例平均值在50%以上。源解析结果显示,夏季TSP主要来源于土壤尘,其次是建筑尘和煤烟尘,其贡献率分别为40.70%~55.49%、9.62%~13.64%和5.85%~17.28%。  相似文献   

16.
2-Ethyl-1-hexanol is a possibly causative chemical in sick building symptoms, although 2-ethyl-1-hexanol has received little attention as a hazardous substance in studies on indoor air pollution. Airborne 2-ethyl-1-hexanol concentrations were measured from 2002 to 2004 in 99 rooms of 42 non-domestic buildings in Nagoya, Japan. The diffusive sampling method is effective for the measurement of a low level of 2-ethyl-1-hexanol in indoor air. The geometric mean (geometric standard deviation) of 2-ethyl-1-hexanol concentrations was 16.5 (5.4) microg m(-3) in indoor air and 1.9 (2.2) microg m(-3) in outdoor air. The maximum concentration of 2-ethyl-1-hexanol in indoor air and outdoor air was 2709 microg m(-3) and 12.4 microg m(-3), respectively. Fewer rooms in a small number of new buildings showed high concentrations of 2-ethyl-1-hexanol, while low concentrations were observed in many rooms of these buildings as well as the other new buildings. The room-to-room concentrations of 2-ethyl-1-hexanol in each building exhibited a wide variation. The geometric mean of the 2-ethyl-1-hexanol concentrations was significantly higher for indoor air than for outdoor air (p < 0.01). The correlation of the 2-ethyl-1-hexanol concentrations between indoor and outdoor air was not significant. Mechanical ventilation was effective in the temporary reduction of indoor 2-ethyl-1-hexanol level. These results suggest that the predominant source of 2-ethyl-1-hexanol was indoor areas.  相似文献   

17.
An experimental system was developed for the rapid measurement of the aspiration/transfer efficiency of aerosol samplers in a wind tunnel. We attempted to measure the aspiration and particle transfer characteristics of two inlets commonly used for sampling airborne Particulate Matter (PM): the 'Total Suspended Particulate' or TSP inlet, and the louvered 'dichotomous sampler inlet' typically used in sampling PM10 or PM2.5. We were able to determine the fraction of the external aerosol that enters the inlet and is transferred through it, and hence is available for collection by a filter, or further size fractionation into PM10 or PM2.5. This 'sampling efficiency' was analysed as a function of dimensionless aerodynamic parameters in order to understand the factors governing inlet performance. We found that for the louvered inlet the sampling efficiency increases as the external wind increases. Under all conditions expected in practical use the louvered inlet aspirates sufficient PM to allow either PM10 or PM2.5 to be selected downstream. The TSP inlet's sampling efficiency decreases with increasing external wind, and the TSP inlet is likely to under-sample the coarse end of the PM10 fraction at moderate and high external winds. As this inlet is generally not used with a downstream size fractionator, changes in sampling efficiency directly affect the measured aerosol concentration. We also investigated whether it is possible to dimensionally scale the PM inlets to operate at either higher or lower flow rates, while preserving the same sampling characteristics as the current full-scale, 16.67 L min(-1) versions. In the case of the louvered inlet, our results indicate that scaling to lower flow rates is possible; scaling to higher flow rates was not tested. For the TSP sampler, the sampling efficiency changes if the sampler is scaled to operate at smaller or larger flow rates, leading to unreliable performance.  相似文献   

18.
Despite strong longitudinal associations between particle personal exposures and ambient concentrations, previous studies have found considerable inter-personal variability in these associations. Factors contributing to this inter-personal variability are important to identify in order to improve our ability to assess particulate exposures for individuals. This paper examines whether ambient, home outdoor and home indoor particle concentrations can be used as proxies of corresponding personal exposures. We explore the strength of the associations between personal, home indoor, home outdoor and central outdoor monitoring site ("ambient site") concentrations of sulfate, fine particle mass (PM(2.5)) and elemental carbon (EC) by season and subject for 25 individuals living in the Boston, MA, USA area. Ambient sulfate concentrations accounted for approximately 70 to 80% of the variability in personal and indoor sulfate levels. Correlations between ambient and personal sulfate, however, varied by subject (0.1-1.0), with associations between personal and outdoor sulfate concentrations generally mirroring personal-ambient associations (median subject-specific correlations of 0.8 to 0.9). Ambient sulfate concentrations are good indicators of personal exposures for individuals living in the Boston area, even though their levels may differ from actual personal exposures. The strong associations for sulfate indicate that ambient concentrations and housing characteristics are the driving factors determining personal sulfate exposures. Ambient PM(2.5) and EC concentrations were more weakly associated with corresponding personal and indoor levels, as compared to sulfate. For EC and PM(2.5), local traffic, indoor sources and/or personal activities can significantly weaken associations with ambient concentrations. Infiltration was shown to impact the ability of ambient concentrations to reflect exposures with higher exposures to particles from ambient sources during summer. In contrast in the winter, lower infiltration can result in a greater contribution of indoor sources to PM(2.5) and EC exposures. Placing EC monitors closer to participants' homes may reduce exposure error in epidemiological studies of traffic-related particles, but this reduction in exposure error may be greater in winter than summer. It should be noted that approximately 20% of the EC data were below the field limit of detection, making it difficult to determine if the weaker associations with the central site for EC were merely a result of methodological limitations.  相似文献   

19.
Phthalates are found in numerous consumer products, including interior materials like polyvinyl chloride (PVC). Several studies have identified phthalates in indoor air. A recent case-control study demonstrated associations between allergic symptoms in children and the concentration of phthalates in dust collected from their homes. Here we have analyzed the content of selected phthalates in particulate matter (PM): PM(10) and PM(2.5) filter samples collected in 14 different indoor environments. The results showed the presence of the phthalates di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), dicyclohexyl phthalate (DCHP) and diethyl hexyl phthalate (DEHP) in the samples. The dominating phthalate in both PM(10) and PM(2.5) samples from all locations was DBP. More than a 10-fold variation in the mean concentration of total phthalates between sampling sites was observed. The highest levels of total phthalates were detected in one children's room, one kindergarten, in two primary schools, and in a computer room. The relative contribution of total phthalates in PM(10) and PM(2.5) was 1.1 +/- 0.3% for both size fractions. The contribution of total phthalates in PM(2.5) to total phthalates in PM(10) ranged from 23-81%, suggesting different sources. Of the phthalates that were analyzed in the PM material, DBP was found to be the major phthalate in rubber from car tyres. However, our analyses indicate that tyre wear was of minor importance for indoor levels of both DBP as well as total phthalates. Overall, these results support the notion that inhalation of indoor PM contributes to the total phthalate exposure.  相似文献   

20.
A long-term series (2001-2008) of chemical analysis of atmospheric particulate matter (PM(10) and PM(2.5)) collected in the city of Huelva (SW Spain) is considered in this study. The impact of emission plumes from one of the largest Cu-smelters in the world on air quality in the city of Huelva is evidenced by the high daily and hourly levels of As, other potentially toxic elements (e.g. Cu, Zn, Cd, Se, Bi, and Pb) in particulate matter, as well as the high levels of some gaseous pollutants (NO(2) and SO(2)). Mean arsenic levels in the PM10 fraction were higher than the target value set by European Directive 2004/107/EC (6 ngAs m(-3)) for 1(st) January 2013. Hourly peak concentrations of As and other metals and elements (Zn, Cu, P and Se) analyzed by PIXE can reach maximum hourly levels as high as 326 ngAs m(-3), 506 ngZn m(-3), 345 ngCu m(-3), 778 ngP m(-3) and 12 ngSe m(-3). The contribution of Cu-smelter emissions to ambient PM is quantified on an annual basis in 2.0-6.7 μg m(-3) and 1.8-4.2 μg m(-3) for PM(10) and PM(2.5), respectively. High resolution outputs of the HYSPLIT dispersion model show the geographical distribution of the As ambient levels into the emission plume, suggesting that the working regime of the Cu-smelter factory and the sea breeze circulation are the main factors controlling the impact of the Cu-smelter on the air quality of the city. The results of this work improve our understanding of the behaviour of industrial emission plumes and their impact on air quality of a city, where the population might be exposed to very high ambient concentrations of toxic metals during a few hours.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号