首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lignite mining operations and lignite-fired power stations result in major particulate pollution (fly ash and fugitive dust) problems in the areas surrounding these activities. The problem is more complicated, especially, for urban areas located not far from these activities, due to additional contribution from the urban pollution sources. Knowledge of the distribution of airborne particulate matter into size fraction has become an increasing area of focus when examining the effects of particulate pollution. On the other hand, airborne particle concentration measurements are useful in order to assess the air pollution levels based on national and international air quality standards. These measurements are also necessary for developing air pollutants control strategies or for evaluating the effectiveness of these strategies, especially, for long periods. In this study an attempt is made in order to investigate the particle size distribution of fly ash and fugitive dust in a heavy industrialized (mining and power stations operations) area with complex terrain in the northwestern part of Greece. Parallel total suspended particulates (TSP) and particulate matter with an aerodynamic diameter less than 10 μm (PM10) concentrations are analyzed. These measurements gathered from thirteen monitoring stations located in the greater area of interest. Spatial, temporal variation and trend are analyzed over the last seven years. Furthermore, the geographical variation of PM10 – TSP correlation and PM10/TSP ratio are investigated and compared to those in the literature. The analysis has indicated that a complex system of sources and meteorological conditions modulate the particulate pollution of the examined area.  相似文献   

2.
Surface coal mining creates more air pollution problems with respect to dust than underground mining . An investigation was conducted to evaluate the characteristics of the airborne dust created by surface coal mining in the Jharia Coalfield. Work zone air quality monitoring was conducted at six locations, and ambient air quality monitoring was conducted at five locations, for a period of 1 year. Total suspended particulate matter (TSP) concentration was found to be as high as 3,723 μg/m3, respirable particulate matter (PM10) 780 μg/m3, and benzene soluble matter was up to 32% in TSP in work zone air. In ambient air, the average maximum level of TSP was 837 μg/m3, PM10 170 μg/m3 and benzene soluble matter was up to 30%. Particle size analysis of TSP revealed that they were more respirable in nature and the median diameter was around 20 μm. Work zone air was found to have higher levels of TSP, PM10 and benzene soluble materials than ambient air. Variations in weight percentages for different size particles are discussed on the basis of mining activities. Anionic concentration in TSP was also determined. This paper concludes that more stringent air quality standards should be adopted for coal mining areas and due consideration should be given on particle size distribution of the air-borne dust while designing control equipment.  相似文献   

3.
The purpose of this work was to determine some aspects of micromorphology of total suspended particles (TSP) and particulate matter with aerodynamic diameter ≤10 μm (PM(10)) and their major elemental components in order to highlight the main characteristics of the atmospheric particles from an urban environment, having a case study in the urban area of Bucharest. The sampling of PM(10) and TSP were conducted in the close vicinity of a high traffic road for 72 h per sample and also priority pollutants in air: Pb and Cd were quantified and correlations between their concentrations and local wind directions were also found. The parameters characterizing the micromorphology of particle-roughness of the particle surface and area of particle-were correlated with wind direction.  相似文献   

4.
This study assessed concentration levels of particulate matter (PM) in the ambient environment of Ilorin metropolis, Nigeria, during haze episodes. Meteorological data (wind speed and direction, rainfall data, sunshine data, relative humidity and temperature) were obtained. Aerocet 531S particle counter (MetOne Instruments, USA) was used to measure four mass concentration ranges of PM (PM1.0, PM2.5, PM10 and the total suspended particles (TSP)) in 10 locations taking into consideration land use patterns. Surfer® version 8 (Golden Software LLC, USA) was used to model the spatial variation of particulate matter concentration levels using kriging interpolation griding method. Human exposure assessment was done using the total respiratory deposition dose (TRDD) estimates and statutory limit breach (SLB) approaches. The appearance of dominating weak southern atmospheric wind flow was observed as wind speed ranged from 0 to 6.811 m/s while solar radiation periods ranged from 0.3 to 3.5 h/day. The relative humidity of the metropolis ranged between 28 and 57%, while daily temperature was 15 to 36 °C. Highest concentration levels of PM measured were 73.4, 562.7, 7066.3 and 9907.8 μg/m3 for PM1.0, PM2.5, PM10 and TSP, respectively. Very strong negative correlations existed between the PM concentration levels and microclimatic parameters. Spatial variation of the concentration level as modelled using Surfer® version 8 indicated that particulate concentration level increases from south to north. Concentration levels of PM for the 24-h averaging period were generally above the 24-h threshold limit value set by the regulatory agencies for all the locations.  相似文献   

5.
Total suspended particulate (TSP), PM(2.5) and BTEX were collected in nine offices in the province of Antwerp, Belgium. Both indoor and outdoor aerosol samples were analysed for their weight, elemental composition, and water-soluble fraction. Indoor TSP and PM(2.5) concentrations ranged from 7-31 microg m(-3) and 5-28 microg m(-3), with an average of 18 and 11 microg m(-3), respectively. Of all the elements analysed in indoor TSP, more than 95% was represented by Al, Si, K, Ca, Fe, Cl and S, accounting for 12% of the TSP by mass. The other elements showed significant enrichment relative to the earth's crust. The water-soluble ionic fraction accounted for almost 30% of the sampled indoor TSP by weight, and was enriched by anthropogenic activities. It was shown that the indoor PM levels varied among the offices, depending on the ventilation pattern, location, and occupation density of the office. Indoor BTEX levels ranged together from 5-47 microg m(-3) and were considerably higher than the corresponding outdoor levels. It was observed that some recently constructed and renovated buildings were clearly burdened with elevated levels for toluene, ethyl benzene, and xylenes, while outdoor air was found to be the main source for BTEX levels at the 'older' offices.  相似文献   

6.
The objective of the study is to investigate seasonal and spatial variations of PM10 (particulate matter with aerodynamic diameter less than or equal to 10 μm) and TSP (total suspended particulate matter) of an Indian Metropolis with high pollution and population density from November 2003 to November 2004. Ambient concentration measurements of PM10 and TSP were carried out at two monitoring sites of an urban region of Kolkata. Monitoring sites have been selected based on the dominant activities of the area. Meteorological parameters such as wind speed, wind direction, rainfall, temperature and relative humidity were also collected simultaneously during the sampling period from Indian Meteorological Department, Kolkata. The 24 h average concentrations of PM10 and TSP were found in the range 68.2–280.6 μg/m3 and 139.3–580.3 μg/m3 for residential (Kasba) area, while 62.4–401.2 μg/m3 and 125.7–732.1 μg/m3 for industrial (Cossipore) area, respectively. Winter concentrations of particulate pollutants were higher than other seasons, irrespective of the monitoring sites. It indicates a longer residence time of particulates in the atmosphere during winter due to low winds and low mixing height. Spread of air pollution sources and non-uniform mixing conditions in an urban area often result in spatial variation of pollutant concentrations. The higher particulate pollution at industrial area may be attributed due to resuspension of road dust, soil dust, automobile traffic and nearby industrial emissions. Particle size analysis result shows that PM10 is about 52% of TSP at residential area and 54% at industrial area.  相似文献   

7.
Total suspended particles mass concentrations (TSP) and bulk depositions of particulate matter (PM depositions) were measured around a cement plant located in the multi-impacted area to assess the affect of the plant on the ambient air in the vicinity in Izmir, Turkey. TSP samples were collected five times a month whereas PM depositions were sampled monthly at four sites between August 2003 and January 2004. The concentrations of Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, V, and Zn in TSP and PM depositions (except Cu) were reported. Chemical mass balance (CMB) receptor model with local source profiles was run in order to calculate the source contributions of the PM sources to the concentrations of TSP, PM depositions, and trace elements. Traffic was found to be the major contributor to TSP whereas PM depositions dominantly result from area sources including several stone quarries, concrete plants, lime kilns, and asphalt plants in the region. CMB model results indicate that the cement plant is a significant contributor to TSP, PM depositions, and trace elements, particularly Cd.  相似文献   

8.
The aim of this study was to measure the concentration of some metals (Cd, Cr, Cu, Fe, Mn, Ni, Pb, and Ti) in PM(10) samples collected in one urban and one industrial site and to assess that PM(10) total mass measurement may be not sufficient as air quality index due to its complex composition. Metals were determined by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) and differential pulsed anodic stripping voltammetry (DPASV). The measured concentrations were used to calculate the content of metals in the PM(10) total mass, and to estimate the enrichment factors and the correlations between PM(10), metal concentrations and meteorological data for the two sites. The mean PM10 concentration during the sampling period in the urban site exceeded the annual European Union (EU) standard (40 microg/m(3)) and, for some sampling days, the daily EU standard (50 microg/m(3)) was also exceeded. In opposite, both EU standards were never exceeded in the industrial site. The overall metal content was nearly double in the industrial site compared to the urban one, and the mean Ni concentration exceeded the EU annual limit value (10 ng/m(3)). The metals with the highest enrichment factor were Cd, Cu, Ni and Pb for both sites, suggesting a dominant anthropogenic source for these metals. Metal concentrations were very low and typical of rural background during Christmas holidays, when factories were closed. PM(10) total mass measurement is not a sufficient air quality index since the metal content of PM(10) is not related to its total mass, especially in sites with industrial activities. This measurement should be associated with the analysis of toxic metals.  相似文献   

9.
Evidence on the correlation between particle mass and (ultrafine) particle number concentrations is limited. Winter- and spring-time measurements of urban background air pollution were performed in Amsterdam (The Netherlands), Erfurt (Germany) and Helsinki (Finland), within the framework of the EU funded ULTRA study. Daily average concentrations of ambient particulate matter with a 50% cut off of 2.5 microm (PM2.5), total particle number concentrations and particle number concentrations in different size classes were collected at fixed monitoring sites. The aim of this paper is to assess differences in particle concentrations in several size classes across cities, the correlation between different particle fractions and to assess the differential impact of meteorological factors on their concentrations. The medians of ultrafine particle number concentrations were similar across the three cities (range 15.1 x 10(3)-18.3 x 10(3) counts cm(-3)). Within the ultrafine particle fraction, the sub fraction (10-30 nm) made a higher contribution to particle number concentrations in Erfurt than in Helsinki and Amsterdam. Larger differences across the cities were found for PM2.5(range 11-17 microg m(-3)). PM2.5 and ultrafine particle concentrations were weakly (Amsterdam, Helsinki) to moderately (Erfurt) correlated. The inconsistent correlation for PM2.5 and ultrafine particle concentrations between the three cities was partly explained by the larger impact of more local sources from the city on ultrafine particle concentrations than on PM2.5, suggesting that the upwind or downwind location of the measuring site in regard to potential particle sources has to be considered. Also, relationship with wind direction and meteorological data differed, suggesting that particle number and particle mass are two separate indicators of airborne particulate matter. Both decreased with increasing wind speed, but ultrafine particle number counts consistently decreased with increasing relative humidity, whereas PM2.5 increased with increasing barometric pressure. Within the ultrafine particle mode, nucleation mode (10-30 nm) and Aitken mode (30-100 nm) had distinctly different relationships with accumulation mode particles and weather conditions. Since the composition of these particle fractions also differs, it is of interest to test in future epidemiological studies whether they have different health effects.  相似文献   

10.
Springtime urban road dust forms one of the most serious problems regarding air pollution in Finland. The composition and origin of springtime dust was studied in southern Finland with two different methods. Suspended particles (PM10 and TSP) were collected with high volume particle samplers and particle deposition was collected with moss bags. The composition of the PM(1.5-10) fraction was studied using individual particle analysis with SEM/EDX. The deposition in the moss bags was analysed with ICP-MS. The results showed that during the study period, approximately 10% of both PM(1.5-10) particles and the deposition originated from sanding. Other sources in the springtime PM(1.5-10) were e.g. asphalt aggregate or soil and combustion processes. It can be concluded that sanding produced a relatively small amount of particulate matter under the investigated circumstances.  相似文献   

11.
A study for assessment and management of air quality was carried out in the Ib Valley area of the Ib Valley coalfield in Orissa state, India. The 24 h average concentrations of suspended particulate matter (SPM), respirable particulate matter (RPM), sulfur dioxide (SO(2)) and oxides of nitrogen (NO(x)) were determined at regular intervals throughout one year at twelve monitoring stations in residential areas and six monitoring stations in mining/industrial areas. The 24 h average SPM and RPM concentrations were 124.6-390.3 microg m(-3) and 25.9-119.9 microg m(-3) in residential areas, and were 146.3-845.2 microg m(-3) and 45.5-290.5 microg m(-3) in industrial areas. During the study period, 24 h and annual average SPM and RPM concentrations exceeded the respective standards set in the Indian national ambient air quality standard (NAAQS) protocol as well as USEPA, EU, WHO and World Bank standards at most of the residential and industrial areas. However, concentrations of SO(2)(annual average: 24.6-36.1 microg m(-3) and 24 h average: 17.0-46.3 microg m(-3)) and NO(x)(annual average: 23.6-40.9 microg m(-3) and 24 h average: 18.3-53.6 microg m(-3)) were well within the prescribed limit of the NAAQS and international standards in both residential and industrial areas. The temporal variations of SPM and RPM fitted polynomial trends well and on average in the mining area 31.91% of the SPM was RPM. The linear regression correlation coefficients between SPM and RPM and between NO(x) and SO(2) were 0.94 (+/-0.04) and 0.66 (+/-0.10), respectively. The optimum interpolation technique, kriging, determined that maximal concentrations of SPM and RPM occurred within the mining site. Highest concentrations of particulate matter were observed during the winter season followed by summer, autumn and rainy seasons. An action plan is formulated for effective control of air pollution at source, and mitigative measures should include implementation of green belts around the sensitive areas where the concentration of air pollutants exceeds the standard limit.  相似文献   

12.
Ports can generate large quantity of pollutants in the atmosphere due to various activities like loading and unloading,transportation, and construction operations. Determination of the character and quantity of emissions from individual sources is an essential step in any project to control and minimize the emissions.In this study a detailed emission inventory of total suspendedparticulate matter (TSP), particulate matter less than 10 m(PM10), sulfur dioxide (SO2) and nitrogen oxides (NOx) for a port and harbour project near Mumbai is compiled. Results show that the total annual average contributions of TSP and PM10 from all the port activitieswere 872 and 221 t yr-1, respectively. Annual average emissions of gaseous pollutants SO2 and NOxwere 56 and 397 t yr-1, respectively, calculatedby using emission factors for different port activities. The maximum TSP emission (419 t yr -1) was from paved roads, while the least (0.4 t yr-1) was from bulk handling activity. The maximum PM10 emission (123 t yr-1) was from unpaved roads and minimum (0.2 t yr-1) from bulk handling operations. Similarly the ratio of TSP and PM10 emission was highest (5.18) from paved roads and least (2.17) from bulk handling operations. Regression relation was derivedfrom existing emission data of TSP and PM10 from variousport activities. Good correlation was observed between TSP andPM10 having regression coefficient >0.8.  相似文献   

13.
宁波和温州地区夏季大气中不同粒径颗粒物特征分析   总被引:1,自引:0,他引:1  
对宁波地区北仑和奉化站、温州地区乐清站3个监测点夏季TSP、PM10、PM2.5和PM1.0进行监测,测试分析各种粒径颗粒物浓度水平和粒径分布特征,并通过化学质量平衡(CMB)受体模型对颗粒物进行源解析。监测结果显示,夏季宁波、温州地区TSP和PM10日均浓度为0.049~0.134mg/m3和0.025~0.084mg/m3,均未超过我国环境空气质量二级标准;PM2.5日均浓度为0.007~0.069mg/m3,按美国2006年EPA最新标准限值0.035mg/m3衡量,奉化、乐清、北仑站的超标天数占总监测天数的比例分别为75%、40%和37.5%。粒径分布统计结果显示,3个监测站点PM10占TSP的比例为48.78%~86.96%;PM2.5占TSP的比例为33.33%~72.46%;奉化和乐清监测点PM10中PM2.5和PM1.0的比例平均值在50%以上。源解析结果显示,夏季TSP主要来源于土壤尘,其次是建筑尘和煤烟尘,其贡献率分别为40.70%~55.49%、9.62%~13.64%和5.85%~17.28%。  相似文献   

14.
Monitoring air quality in large urban agglomerations is the key to the prevention of air pollution-related problems in emerging mega-cities. The city of Wuhan is a highly industrialised city with >9 million inhabitants in Central China. Simultaneous PM10 sampling was performed during 1 year at one urban and one industrial site. Mean PM10 daily levels (156 microg m(-3) at the urban site and 197 microg m(-3) at the industrial hotspot) exceed the US-EPA or EU annual limit values by 3-4 times. A detailed study of daily speciation showed that the mean chemical composition of PM10 presents minimal differences between peak and low PM episodes. This implies that PM10 aerosols in the study area result from local emissions, and air quality management and abatement strategies in Wuhan should thus focus on local anthropogenic sources. The levels of some elements of environmental concern are relatively high (409-615 ngPb m(-3), 66-70 ngAs m(-3), 116-227 ngMn m(-3), 10-12 ngCd m(-3)) due to industrial, but also urban emissions. Principal component analysis identified a mineral source (probably cement and steel manufacture) and smelting as the main contributors to PM10 levels at the industrial site (34%), followed by a coal fired power plant (20%) and the anthropogenic regional background (16%). At the urban site the major PM10 source is a mixed coal combustion source (31%), followed by the anthropogenic regional background (28%) and traffic (16%).  相似文献   

15.
The concentrations of organochlorine pesticides (OCPs) in atmospheric particulate matter in Jinan, China, over the period from July 2009 to June 2010, were determined to study their pollution levels, compositions, size distribution and seasonal variations. All target compounds except endosulfan sulfate were detected. The annual average concentration of ∑18 OCPs was 92 ± 82 pg m(-3). Total HCH, total endrin, aldrin, endosulfan compounds and total DDT compounds were the primary components, accounting for approximately 27%, 20%, 16%, 14% and 10% of total OCPs, respectively. The annual mean ng g(-1) concentrations of ∑18 OCPs in PM(2.5), PM(5), PM(10) and TSP were 481 ± 190, 433 ± 161, 414 ± 158 and 264 ± 193, respectively, indicating that most OCPs tend to be strongly absorbed by fine air particles which were strongly related to a potential health risk. Distinct seasonal trends were found in OCPs concentrations with high concentrations appearing in November and March whereas low concentrations appeared in the summer, which were significantly positively correlated with particulate mass concentrations and Air Pollution Index (API). The high OCPs levels could be attributed to the seasonal usage, long-range atmospheric transport as well as adverse meteorological conditions.  相似文献   

16.
A long-term series (2001-2008) of chemical analysis of atmospheric particulate matter (PM(10) and PM(2.5)) collected in the city of Huelva (SW Spain) is considered in this study. The impact of emission plumes from one of the largest Cu-smelters in the world on air quality in the city of Huelva is evidenced by the high daily and hourly levels of As, other potentially toxic elements (e.g. Cu, Zn, Cd, Se, Bi, and Pb) in particulate matter, as well as the high levels of some gaseous pollutants (NO(2) and SO(2)). Mean arsenic levels in the PM10 fraction were higher than the target value set by European Directive 2004/107/EC (6 ngAs m(-3)) for 1(st) January 2013. Hourly peak concentrations of As and other metals and elements (Zn, Cu, P and Se) analyzed by PIXE can reach maximum hourly levels as high as 326 ngAs m(-3), 506 ngZn m(-3), 345 ngCu m(-3), 778 ngP m(-3) and 12 ngSe m(-3). The contribution of Cu-smelter emissions to ambient PM is quantified on an annual basis in 2.0-6.7 μg m(-3) and 1.8-4.2 μg m(-3) for PM(10) and PM(2.5), respectively. High resolution outputs of the HYSPLIT dispersion model show the geographical distribution of the As ambient levels into the emission plume, suggesting that the working regime of the Cu-smelter factory and the sea breeze circulation are the main factors controlling the impact of the Cu-smelter on the air quality of the city. The results of this work improve our understanding of the behaviour of industrial emission plumes and their impact on air quality of a city, where the population might be exposed to very high ambient concentrations of toxic metals during a few hours.  相似文献   

17.
An investigation to find out presence of particulate matter in Marikana, a mining area in Rustenburg town, South Africa, was carried out in the months of August and November of 2008. Samples were collected for measurements of particulate matter (PM) of particle diameters of PM10, PM2.5, and PM1. After gravimetric analysis of daily measurements, it was found that PM10 concentration values ranged between 3 and 9 ??g/m3, PM2.5 concentration values ranged between 16 and 26 ??g/m3, and PM1 concentration values ranged between 14 and 18 ??g/m3 for the month of August 2008. For the month of November, it was found that PM10 concentration values ranged between 2 and 8 ??g/m3, PM2.5 concentration values ranged between 0 and 5 ??g/m3, and PM1 concentration values ranged between 4 and 15 ??g/m3. This study was undertaken as preliminary work having in mind that mining activities could be emitting high levels of particulate matter in the atmosphere which might be degrading the quality of the air. It was observed, however, that the daily particulate matter especially of PM10 emitted were quite low when compared to laid down International Air Quality Standards. The standards did not give guidelines for particulate matter of diameter 2.5 ??m. It was concluded that particulate matter came from three major sources: platinum mining, domestic biomass burning, and traffic emissions due to fuel burning.  相似文献   

18.
库尔勒市大气颗粒物污染特征与影响因素分析   总被引:1,自引:0,他引:1  
针对库尔勒市PM 10、PM 2.5年均浓度超标现象,基于市区3个环境监测站2013—2017年的逐时观测数据,分析PM 10、PM 2.5污染特征、成因及其主要影响因素。结果表明:①2013—2017年库尔勒市PM 10年均浓度变化较大且无明显趋势,PM 2.5年均浓度整体呈下降趋势;②季节尺度上,库尔勒市PM 10在每年2—5月呈现高浓度,PM 2.5高浓度期则为10月至翌年5月;③城郊的开发区站PM 10浓度最高,老城区的州政府站PM 2.5浓度最高,在PM 10和PM 2.5的高浓度期空间差异尤其显著;④PM 10与风速显著正相关,来自塔克拉玛干沙漠的风蚀沙尘颗粒物是库尔勒地区颗粒污染物的主要来源;⑤库尔勒市PM 10主要为外源输入,PM 2.5则以城市内源为主,相对湿度、风速、风向、温度等气象条件是影响大气颗粒物浓度及分布的重要因素。  相似文献   

19.
Port causes environmental and health concerns in coastal cities if its operation and development are not made environmentally compatible and sustainable. An emission inventory is necessary to assess the impact of port projects or growth in marine activity as well as to plan mitigation strategies. In this study, a detailed emission inventory of total suspended particulate (TSP) matter, respirable particulate matter (PM10), sulphur dioxide (SO2) and oxides of nitrogen (NOx) for a port having operation and construction activities in parallel is compiled. The study has been done for 1 year. Results show that the maximum contribution of emission of air pollutants in the port area was from TSP (68.5%) and the minimum was from SO2 (5.3%) to the total pollutants considered in this study. Total TSP emission from all activities of the port was 4,452 tyr???1 and PM10 emission was 903 tyr???1 in the year 2006. Re-suspension of dust from paved roads was the major contributor of TSP and PM10 in the road transport sector. Construction activities of the port had contributed 3.9% of TSP and 7.4% of PM10 to total emission of particulate matter. Of the total particulate emissions from various port activities approximately 20% of TSP could be attributed to PM10. The sectoral composition indicates that major contribution of SO2 emission in the port was from maritime sector and major contribution of NOx was from road transport sector.  相似文献   

20.
The Helsinki Metropolitan Area Council (YTV) is responsible for air quality monitoring in the Helsinki area. Air quality has been monitored periodically since the late 1950s. An automatic SO2 monitoring network was constructed in 1975 and TSP measurements were added in 1978. Since then the network has been expanded and currently five automatic multicomponent stations form the basis of the network monitoring SO2, NO, NO2, CO, PM10 and O3 concentrations. Manual TSP and PM10 measurements are also conducted. Mobile monitoring units are also being used as well as special measurement campaigns. The effects of air pollution on nature are studied in bioindicator monitoring. An air quality index is used in order to inform the public of the current air quality situation. Changes in air quality are reflected in monitoring strategy. SO2 concentrations have decreased in the past two decades. Annual averages in 1995 were at or below 5 µg/m3. Traffic is the major source for pollutants even though catalytic converters have lowered traffic emissions somewhat. The highest annual average NO2 concentration at an urban site was 49 µg/m3 in 1995, and there has been no clear change in NO2 levels. There has been a decreasing trend in CO concentrations. Maximum annual TSP and PM10 averages in 1995 were 92 and 32 µg/m3, respectively. The highest average lead concentration was 0.01 µg/m3. Elevated concentrations are experienced from time to time. During the spring daily TSP and PM10 concentrations can go up to around 300 and 150 µg/m3, respectively. This is caused by resuspension mainly due to street sanding. Also a major winter NO2 episode occurred in December 1995. The highest hourly NO2 concentrations reached 400 µg/m3.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号