首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Source apportionment study was performed, applying principal component analysis to the results of 221 chemical analyses of PM10 and PM2.5 samples collected daily from the industrial (but low traffic) Spanish town of Puertollano over a 14-month period during 2004-2005. Results reveal compositional variations attributable to different mixtures of natural and anthropogenic materials, mainly soil and rock dust (crustal), marine salt (only in PM10), petrochemical refinery emissions, and particles attributed to the combustion of local coal, which is unusually rich in Pb and Sb. During the study period there were 34 pollution episodes when PM10 exceeded 50 tg m(-3), mostly due to winter air temperature inversions, regional atmospheric stagnation, or African dust incursions (North African, NAF days: usually in summer). Whereas the crustal component during NAF episodes averaged 52% with a PM2.5/PM10 ratio of 0.54, this dropped to 29% and a PM2.5/PM10 of 0.67 during non-NAF days when anthropogenic materials predominated. Abnormally enhanced concentrations of pathfinder metallic trace elements provide additional evidence for source apportionment: thus aerosols with raised levels of Pb and Sb are associated with local coal combustion, Ni and V can be linked to petrochemical PM emissions, and Ti, Mn, Rb, and Ce are particularly characteristic of crustal dust incursions.  相似文献   

3.
This study characterizes the exposure of a typical Indian Institute of Technology Kanpur student to particulate matter and gaseous co-pollutants like carbon monoxide, volatile organic compounds, and nitrogen dioxide in various microenvironments, within and outside the college campus. Chemical analysis of filter, used for the particulate matter measurement, was also carried out to determine the concentration of various elements such as Ca, Cd, Cr, Cu, Fe, Mg, Pb, Zn, and anions like F?, Cl?, NO3 ?, and SO4 2?. Furthermore, time activity diary along with temperature data was maintained for the precise evaluation and analysis of results for various microenvironments. The results showed PM10 and PM2.5 concentrations to be higher at some outdoor microenvironments, particularly near the Ganga riverbank. From the chemical analysis, concentrations of chloride and fluoride were found higher in indoor microenvironments as compared to outdoors. Also, nitrate concentrations were quite higher within the laboratory premises. Concentrations of Ca, Fe, and Mg were significant outdoors, whereas Na, Ca, Fe, and K were prominent indoors. The study highlights the real-time personal exposure of a student cohort to various toxic pollutants typically found within their breathing levels and their potential sources both indoors and outdoors.  相似文献   

4.
This complex study presents indoor and outdoor levels of air-borne fine particles, particle-bound PAHs and VOCs at two urban locations in the city of Kaunas, Lithuania, and considers possible sources of pollution. Two sampling campaigns were performed in January-February and March-April 2009. The mean outdoor PM(2.5) concentration at Location 1 in winter was 34.5 ± 15.2 μg m(-3) while in spring it was 24.7 ± 12.2 μg m(-3); at Location 2 the corresponding values were 36.7 ± 21.7 and 22.4 ± 19.4 μg m(-3), respectively. In general there was little difference between the PM concentrations at Locations 1 and 2. PM(2.5) concentrations were lower during the spring sampling campaign. These PM concentrations were similar to those in many other European cities; however, the levels of most PAHs analysed were notably higher. The mean sum PAH concentrations at Locations 1 and 2 in the winter campaign were 75.1 ± 32.7 and 32.7 ± 11.8 ng m(-3), respectively. These differences are greater than expected from the difference in traffic intensity at the two sites, suggesting that there is another significant source of PAH emissions at Location 1 in addition to the traffic. The low observed indoor/outdoor (I/O) ratios indicate that PAH emissions at the locations studied arise primarily from outdoor sources. The buildings at both locations have old windows with wooden frames that are fairly permissive in terms of air circulation. VOC concentrations were mostly low and comparable to those reported from Sweden. The mean outdoor concentrations of VOC's were: 0.7 ± 0.2, 3.0 ± 0.8, 0.5 ± 0.2, 3.5 ± 0.3, and 0.2 ± 0.1 μg m(-3), for benzene, toluene, ethylbenzene, sum of m-, p-, o-xylenes, and naphthalene, respectively. Higher concentrations of VOCs were observed during the winter campaign, possibly due to slower dispersion, slower chemical transformations and/or the lengthy "cold start" period required by vehicles in the wintertime. A trajectory analysis showed that air masses coming from Eastern Europe carried significantly higher levels of PM(2.5) compared to masses from other regions, but the PAHs within the PM(2.5) are of local origin. It has been suggested that street dust, widely used for winter sanding activities in Eastern and Central European countries, may act not only as a source of PM, but also as source of particle-bound PAHs. Other potential sources include vehicle exhaust, domestic heating and long-range transport.  相似文献   

5.
天津市颗粒物中元素化学特征及来源   总被引:4,自引:0,他引:4  
2006年的8月—12月采集天津市PM2.5和PM10样品,分析了Na、Al等17种元素质量浓度及月变化特征,PM2.5中元素平均质量浓度为17.2μg/m3,占PM2.5的10.3%。微量元素Zn、Pb在PM10和PM2.5中含量较高,Cr、V、Ni、As等则在细粒子中有明显分布。用富集因子法分析发现,PM2.5中元素富集程度高于PM10。地壳元素除Ca外,均无明显富集,微量元素则呈现不同程度的富集,以Cd富集最为明显。颗粒物分析表明,土壤尘、燃煤、机动车尾气及化工行业是PM2.5中无机元素的主要来源。  相似文献   

6.
In the study reported here semipermeable membrane devices (SPMDs) were used to sample 28 PAHs and 19 PCBs in the gas phase in 15 single-family houses located in an area where domestic wood burning is widespread. Eight of the households used wood burning appliances whereas the others used other systems for residential heating. Most of the studied compounds were found in the houses: the PAHs at levels that were similar to or slightly higher than published SPMD-sampled levels for background or urban sites in Sweden, and the PCBs at levels that were somewhat lower than those recently found in both indoor and outdoor urban locations. A principal component analysis revealed that wood-burning heating systems may contribute to PAHs in indoor air. The sources may be emissions indoors or penetration from outdoors. The convenience of SPMD technology facilitates its use for semi-quantitative screening and monitoring of various persistent organic compounds indoors in dwellings and working environments.  相似文献   

7.
Systematic sampling and analysis were performed to investigate the dynamics and the origin of suspended particulate matter smaller than 2.5 μm in diameter (PM(2.5)), in Beijing, China from 2005 to 2008. Identifying the source of PM(2.5) was the main goal of this project, which was funded by the German Research Foundation (DFG). The concentrations of 19 elements, black carbon (BC) and the total mass in 158 weekly PM(2.5) samples were measured. The statistical evaluation of the data from factor analysis (FA) identifies four main sources responsible for PM(2.5) in Beijing: (1) a combination of long-range transport geogenic soil particles, geogenic-like particles from construction sites and the anthropogenic emissions from steel factories; (2) road traffic, industry emissions and domestic heating; (3) local re-suspended soil particles; (4) re-suspended particles from refuse disposal/landfills and uncontrolled dumped waste. Special attention has been paid to seven high concentration "episodes", which were further analyzed by FA, enrichment factor analysis (EF), elemental signatures and backward-trajectory analysis. These results suggest that long-range transport soil particles contribute much to the high concentration of PM(2.5) during dust days. This is supported by mineral analysis which showed a clear imprint of component in PM(2.5). Furthermore, the ratios of Mg/Al have been proved to be a good signature to trace back different source areas. The Pb/Ti ratio allows the distinction between periods of predominant anthropogenic and geogenic sources during high concentration episodes. Backward-trajectory analysis clearly shows the origins of these episodes, which partly corroborate the FA and EF results. This study is only a small contribution to the understanding of the meteorological and source driven dynamics of PM(2.5) concentrations.  相似文献   

8.
The paper discusses ambient concentrations of PM2.5 (ambient fine particles) and of 29 PM2.5-related elements in Zabrze and Katowice, Poland, in 2007. The elemental composition of PM2.5 was determined using energy dispersive X-ray fluorescence (EDXRF). The mobility (cumulative percentage of the water-soluble and exchangeable fractions of an element in its total concentration) of 18 PM2.5-related elements in Zabrze and Katowice was computed by using sequential extraction and EDXRF combined into a simple method. The samples were extracted twice: in deionized water and in ammonium acetate. In general, the mobility and the concentrations of the majority of the elements were the same in both cities. S, Cl, K, Ca, Zn, Br, Ba, and Pb in both cities, Ti and Se in Katowice, and Sr in Zabrze had the mobility greater than 70%. Mobility of typical crustal elements, Al, Si, and Ti, because of high proportion of their exchangeable fractions in PM, was from 40 to 66%. Mobility of Fe and Cu was lower than 30%. Probable sources of PM2.5 were determined by applying principal component analysis and multiple regression analysis and computing enrichment factors. Great part of PM2.5 (78% in Katowice and 36% in Zabrze) originated from combustion of fuels in domestic furnaces (fossil fuels, biomass and wastes, etc.) and liquid fuels in car engines. Other identified sources were: power plants, soil, and roads in Zabrze and in Katowice an industrial source, probably a non-ferrous smelter or/and a steelwork, and power plants.  相似文献   

9.
Metallic elements (As, Be, Ca, Cd, Co, Cr, Fe, K, Mn, Ni, Pb, Sb, Se, and Zn) in PM10 aerosols were determined at urban and industrial sites, which are affected by traffic and residential sources, metallurgical activity, and petrochemical and steel works. The effect of the long-range transported Asian Dust on the metal content of aerosols was also examined. At the urban sampling site, concentrations of As, Cd, Pb, Se, and Zn were assigned to road traffic and combustion sources, Ca and Fe to soil dust sources from long-range transported Asian Dusts, and Cr and Ni to metallurgical sources transported from the nearby industrial complex, based on Principal Component Analysis (PCA). Enhanced Cr and Ni concentrations at the metallurgical industrial site suggest that local emissions from metal-assembly facilities and manufacture of alloys contributed to elevated levels of those metals. We also observed that petrochemical activities contributed to increased levels of Sb and Zn. When Asian Dust events occurred, Ca, Fe, K, and Zn concentrations dramatically increased compared to values without the Asian Dust. Two different types of Asian Dust events were observed. For the Asian Dust event 1 (4/1/2007), the Fe and K concentrations were much higher by a factor of 2–3 than those for the Asian Dust event 2 (3/2/2008), while As, Mn, and Zn concentrations were significantly higher on the Asian Dust event 2. Backward trajectory analysis showed that for the Asian Dust event 2, the air mass had passed over the heavily industrialized zones in China during long-range transport to the current sampling site, suggesting that the As, Mn, and Zn may have originated from industrial sources.  相似文献   

10.
Aerosol samples of PM10 and PM2.5 are collected in summertime at four monitoring sites in Guangzhou, China. The concentrations of organic and elemental carbons (OC/EC), inorganic ions, and elements in PM10 and PM2.5 are also quantified. Our study aims to: (1) characterize the particulate concentrations and associated chemical species in urban atmosphere (2) identify the potential sources and estimate their apportionment. The results show that average concentration of PM2.5 (97.54 μg m−3) in Guangzhou significantly exceeds the National Ambient Air Quality Standard (NAAQS) 24-h average of 65 μg m−3. OC, EC, Sulfate, ammonium, K, V, Ni, Cu, Zn, Pb, As, Cd and Se are mainly in PM2.5 fraction of particles, while chloride, nitrate, Na, Mg, Al, Fe, Ca, Ti and Mn are mainly in PM2.5-10 fraction. The major components such as sulfate, OC and EC account for about 70–90% of the particulate mass. Enrichment factors (EF) for elements are calculated to indicate that elements of anthropogenic origins (Zn, Pb, As, Se, V, Ni, Cu and Cd) are highly enriched with respect to crustal composition (Al, Fe, Ca, Ti and Mn). Ambient and source data are used in the multi-variable linearly regression analysis for source identification and apportionment, indicating that major sources and their apportionments of ambient particulate aerosols in Guangzhou are vehicle exhaust by 38.4% and coal combustion by 26.0%, respetively.  相似文献   

11.
15 road and 14 soil dust samples were collected from an oilfield city, Dongying, from 11/2009-4/2010 and analyzed by inductively coupled plasma-mass spectroscopy (ICP-MS) for V, Cr, Mn, Co, Ni, Cu, Zn, As, Cd and Pb within PM(2.5), PM(10) and PM(100) fractions synchronously. Metal concentrations, sources and human health risk were studied. Results showed that both soil and road dust exhibited higher values for Mn and Zn and lower values for Co and Cd for the three fractions. Mass concentration ratios of PM(2.5)/PM(10) and PM(10)/PM(100) for metals in road and soil dust indicate that most of the heavy metals tend to concentrate in fine particles. Geoaccumulation index and enrichment factors analysis showed that Cu, Zn and Cd exhibited moderate or heavy contamination and significant enrichment, indicating the influence of anthropogenic sources. Vanadium, Cr, Mn and Co were mostly not enriched and were mainly influenced by crustal sources. For Ni, As and Pb, they ranged from not enriched to moderately enriched and were influenced by both crustal materials and anthropogenic sources. The conclusions were confirmed by multivariate analysis methods. Principle component analysis revealed that the major sources were vehicle emission, industrial activities, coal combustion, agricultural activities and crustal materials. The risk assessment results indicated that metal ingestion appeared to be the main exposure route followed by dermal contact. The most likely cause for cancer and other health risks are both the fine particles of soil and road dusts.  相似文献   

12.
平顶山市大气PM10、PM2.5 污染调查   总被引:1,自引:4,他引:1       下载免费PDF全文
于2003年12月-2004年11月对平顶山市城区大气PM10、PM2.5污染进行了调查.结果表明,2004年大气PM10、PM2.5质量浓度分别为0.031 mg/m3~0.862 mg/m3、0.019 mg/m3~0.438 mg/m3;年均值分别为0.174 mg/m3、0.114 mg/m3,超标0.74倍、6.60倍.PM10、PM2.5污染的季节变化趋势是以冬季、春季高,秋季次之,夏季最低,细颗粒(PM2.5)约占PM10 65%;As、Pb、Cd、S、Zn、Cu、Mn、Ca等元素是颗粒物中主要污染元素,易在PM2.5中富集.平顶山市大气颗粒物污染的主要来源有煤炭燃烧、汽车尾气、城市基础建设和有色金属冶炼行业.  相似文献   

13.
Endotoxin is a toxic, pro-inflammatory compound that has been detected in indoor air and dust in homes and occupational settings, and also in outdoor air. Data on the outdoor sampling of endotoxin are limited. Currently, little is known about the seasonal variation and influence of temperature on outdoor endotoxin levels. In the present study, we report endotoxin levels in fine fraction particulate matter with a 50% aerodynamic cutoff diameter of 2.5 microm (PM2.5) and describe the seasonal variation of endotoxin in Munich, Germany. In 1999-2000, PM2.5 was collected at forty outdoor monitoring sites across Munich. Approximately four samples were collected at each site for a total of 158 samples. Endotoxin concentrations in the PM2.5 samples were determined using the kinetic chromogenic Limulus Amebocyte Lysate (LAL) assay. The geometric mean endotoxin concentration was 1.07 EU mg PM2.5(-1) (95% C.I.: 0.915-1.251) or 0.015 EU m(-3) of sampled air (95% C.I.: 0.013-0.018). Munich endotoxin levels were significantly related to ambient temperature (p < 0.0001) and percent relative humidity (p < 0.0001). Sampling periods with higher average temperatures yielded higher levels of endotoxin in PM2.5 (r = 0.641), whereas decreases in percent relative humidity were associated with increased endotoxin levels in PM2.5 (r = -0.388). Endotoxin levels were significantly higher during the warmer seasons of spring [means ratio (MR): 2.5-2.7] and summer (MR: 2.1-3.0) than during winter. Although temperature and relative humidity do not explain all of the variability in endotoxin levels, their effects were significant in our data set. Temperature effects and seasonal variation of endotoxin should be considered in future studies of outdoor endotoxin.  相似文献   

14.
During March and April 2010 aerosol inventories from four large cities in Pakistan were assessed in terms of particle size distributions (N), mass (M) concentrations, and particulate matter (PM) concentrations. These M and PM concentrations were obtained for Karachi, Lahore, Rawalpindi, and Peshawar from N concentrations using a native algorithm based on the Grimm model 1.109 dust monitor. The results have confirmed high N, M and PM concentrations in all four cities. They also revealed major contributions to the aerosol concentrations from the re-suspension of road dust, from sea salt aerosols, and from vehicular and industrial emissions. During the study period the 24 hour average PM(10) concentrations for three sites in Karachi were found to be 461 μg m(-3), 270 μg m(-3), and 88 μg m(-3), while the average values for Lahore, Rawalpindi and Peshawar were 198 μg m(-3), 448 μg m(-3), and 540 μg m(-3), respectively. The corresponding 24 hour average PM(2.5) concentrations were 185 μg m(-3), 151 μg m(-3), and 60 μg m(-3) for the three sites in Karachi, and 91 μg m(-3), 140 μg m(-3), and 160 μg m(-3) for Lahore, Rawalpindi and Peshawar, respectively. The low PM(2.5)/PM(10) ratios revealed a high proportion of coarser particles, which are likely to have originated from (a) traffic, (b) other combustion sources, and (c) the re-suspension of road dust. Our calculated 24 hour averaged PM(10) and PM(2.5) concentrations at all sampling points were between 2 and 10 times higher than the maximum PM concentrations recommended by the WHO guidelines. The aerosol samples collected were analyzed for crustal elements (Al, Fe, Si, Mg, Ca) and trace elements (B, Ba, Cr, Cu, K, Na, Mn, Ni, P, Pb, S, Sr, Cd, Ti, Zn and Zr). The averaged concentrations for crustal elements ranged from 1.02 ± 0.76 μg m(-3) for Si at the Sea View location in Karachi to 74.96 ± 7.39 μg m(-3) for Ca in Rawalpindi, and averaged concentrations for trace elements varied from 7.0 ± 0.75 ng m(-3) for B from the SUPARCO location in Karachi to 17.84 ± 0.30 μg m(-3) for Na at the M. A. Jinnah Road location, also in Karachi.  相似文献   

15.
Despite strong longitudinal associations between particle personal exposures and ambient concentrations, previous studies have found considerable inter-personal variability in these associations. Factors contributing to this inter-personal variability are important to identify in order to improve our ability to assess particulate exposures for individuals. This paper examines whether ambient, home outdoor and home indoor particle concentrations can be used as proxies of corresponding personal exposures. We explore the strength of the associations between personal, home indoor, home outdoor and central outdoor monitoring site ("ambient site") concentrations of sulfate, fine particle mass (PM(2.5)) and elemental carbon (EC) by season and subject for 25 individuals living in the Boston, MA, USA area. Ambient sulfate concentrations accounted for approximately 70 to 80% of the variability in personal and indoor sulfate levels. Correlations between ambient and personal sulfate, however, varied by subject (0.1-1.0), with associations between personal and outdoor sulfate concentrations generally mirroring personal-ambient associations (median subject-specific correlations of 0.8 to 0.9). Ambient sulfate concentrations are good indicators of personal exposures for individuals living in the Boston area, even though their levels may differ from actual personal exposures. The strong associations for sulfate indicate that ambient concentrations and housing characteristics are the driving factors determining personal sulfate exposures. Ambient PM(2.5) and EC concentrations were more weakly associated with corresponding personal and indoor levels, as compared to sulfate. For EC and PM(2.5), local traffic, indoor sources and/or personal activities can significantly weaken associations with ambient concentrations. Infiltration was shown to impact the ability of ambient concentrations to reflect exposures with higher exposures to particles from ambient sources during summer. In contrast in the winter, lower infiltration can result in a greater contribution of indoor sources to PM(2.5) and EC exposures. Placing EC monitors closer to participants' homes may reduce exposure error in epidemiological studies of traffic-related particles, but this reduction in exposure error may be greater in winter than summer. It should be noted that approximately 20% of the EC data were below the field limit of detection, making it difficult to determine if the weaker associations with the central site for EC were merely a result of methodological limitations.  相似文献   

16.
利用PM2.5/PM10便携式采样器采集了乌鲁木齐市5个功能区PM2.5,样品,用TAS-990石墨炉原子吸收光谱仪检测了PM2.5样品中Cd、Cu、Ni、Pb、Mn的含量。结果表明,乌鲁木齐大气PM2.5质量浓度变化趋势是冬季采暖盛期〉秋季采暖初期〉春季停暖初期〉夏季停暖期。参照《环境空气质量标准》(GB3095—2012)中的二级标准,采样期间卡子湾水泥厂区样品全部超标,其余4个采样点样品在冬季采暖盛期也全部超标,部分样品在非采暖期超标。富集因子法分析表明,乌鲁木齐市5个采样区PM2.5样品中Ni、Cu、Cd、Pb污染主要来自于人类活动,Mn则来源于地壳物质。  相似文献   

17.
Atmospheric pollutants from livestock operations influence air quality inside livestock buildings and the air exhausted from them. The climate that prevails inside the building affects human and animal health and welfare, as well as productivity, while emissions from the building contribute to environmental pollution. The aim of this study was to examine the variation of two climatic parameters (namely temperature and relative humidity) and the levels of particulate matter of different sizes (PM10-PM2.5-PM1), as well as the relationships between them, inside a typical Greek naturally ventilated livestock building that hosts mainly sheep. The concentration of particles was recorded during a 45-day period (27/11-10/1), while temperature and relative humidity were observed during an almost 1-year period. The analysis revealed that the variation of outdoor weather conditions significantly influenced the indoor environment, as temperature and relative humidity inside the building varied in accordance to the outside climate conditions. Temperature remained higher indoors than outdoors during the winter and extremely low values were not recorded inside the building. However, the tolerable relative humidity levels recommended by the International Commission of Agricultural Engineering (CIGR) were fulfilled only in 47% of the hours during the almost 1-year period that was examined. This fact indicates that although temperature was satisfactorily controlled, the control of relative humidity was deficient. The concentration of particulate matter was increased during the cold winter days due to poor ventilation. The maximum daily average value of PM10, PM2.5 and PM1 concentration equaled to 363, 61 and 30?μg/m(3) respectively. The concentration of the coarse particles was strongly influenced by the farming activities that were daily taking place in the building, the dust resuspension being considered as the dominant source. A significant part of the fine particles were secondary, which the production of could be attributed to an increase in relative humidity levels. It is concluded that measures have to be adopted in order to achieve sufficient ventilation and to reduce particulate matter levels.  相似文献   

18.
Total suspended particulate (TSP), PM(2.5) and BTEX were collected in nine offices in the province of Antwerp, Belgium. Both indoor and outdoor aerosol samples were analysed for their weight, elemental composition, and water-soluble fraction. Indoor TSP and PM(2.5) concentrations ranged from 7-31 microg m(-3) and 5-28 microg m(-3), with an average of 18 and 11 microg m(-3), respectively. Of all the elements analysed in indoor TSP, more than 95% was represented by Al, Si, K, Ca, Fe, Cl and S, accounting for 12% of the TSP by mass. The other elements showed significant enrichment relative to the earth's crust. The water-soluble ionic fraction accounted for almost 30% of the sampled indoor TSP by weight, and was enriched by anthropogenic activities. It was shown that the indoor PM levels varied among the offices, depending on the ventilation pattern, location, and occupation density of the office. Indoor BTEX levels ranged together from 5-47 microg m(-3) and were considerably higher than the corresponding outdoor levels. It was observed that some recently constructed and renovated buildings were clearly burdened with elevated levels for toluene, ethyl benzene, and xylenes, while outdoor air was found to be the main source for BTEX levels at the 'older' offices.  相似文献   

19.
Airborne particulate trace metals have important health implications. As a consequence, their concentrations are increasingly monitored in many urban locations worldwide. In this study, fine atmospheric particles (PM(2.5)) were collected in Singapore over a period of 83 consecutive days during 2000, and analysed to determine the concentration of trace elements using ICP-MS. Altogether, eighteen airborne trace metals were quantified: Al, Ag, Ba, Cd, Cr, Co, Cu, Fe, Ga, Li, Mn, Ni, Pb, Sr, Zn, V, Si, and Ti. While Li was the least abundant trace metal with a mean concentration of 0.2 ng m(-3), Zn showed the maximum mean concentration of 279.1 ng m(-3). Calculation of enrichment factors indicated that the elements Pb, Zn, Cd, V, Ni, Cr, and Cu were enriched by factors of 30 to 5000 relative to their natural abundance in crustal soil. The extent of metal pollution in the study area was assessed by comparing the measured concentrations to those reported in the literature for a selected number of urban sites in other parts of the world. Factor analysis was used to identify the major sources affecting particulate air pollution in Singapore. The sources that contribute to the loading of trace metal-bearing aerosols in the Singapore urban atmosphere include fuel oil-fired power plants, metal processing industry, land reclamation and construction activities, municipal solid waste incinerators, and traffic emissions.  相似文献   

20.
The relationship between indoor and outdoor particulate air pollution was investigated at an urban background site on the Payambar Azam Campus of Mazandaran University of Medical Sciences in Sari, Northern Iran. The concentration of particulate matter sized with a diameter less than 1 μm (PM1.0), 2.5 μm (PM2.5), and 10 μm (PM10) was evaluated at 5 outdoor and 12 indoor locations. Indoor sites included classrooms, corridors, and office sites in four university buildings. Outdoor PM concentrations were characterized at five locations around the university campus. Indoor and outdoor PM measurements (1-min resolution) were conducted in parallel during weekday mornings and afternoons. No difference found between indoor PM10 (50.1 ± 32.1 μg/m3) and outdoor PM10 concentrations (46.5 ± 26.0 μg/m3), indoor PM2.5 (22.6 ± 17.4 μg/m3) and outdoor PM2.5 concentration (22.2 ± 15.4 μg/m3), or indoor PM1.0 (14.5 ± 13.4 μg/m3) and outdoor mean PM1.0 concentrations (14.2 ± 12.3 μg/m3). Despite these similar concentrations, no correlations were found between outdoor and indoor PM levels. The present findings are not only of importance for the potential health effects of particulate air pollution on people who spend their daytime over a period of several hours in closed and confined spaces located at a university campus but also can inform regulatory about the improvement of indoor air quality, especially in developing countries.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号