首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This article describes the application of on-line nonlinear monitoring of a sequencing batch reactor (SBR). Three-way batch data of SBR are unfolded batch-wisely, and then a adaptive and nonlinear multivariate monitoring method is used to capture the nonlinear characteristics of normal batches. The approach is successfully applied to an 80 L SBR for biological wastewater treatment, where the SBR poses an interesting challenge in view of process monitoring since it is characterized by nonstationary, batchwise, multistage, and nonlinear dynamics. In on-line batch monitoring, the developed adaptive and nonlinear process monitoring method can effectively capture the nonlinear relationship among process variables of a biological process in a SBR. The results of this pilot-scale SBR monitoring system using simple on-line measurements clearly demonstrated that the adaptive and nonlinear monitoring technique showed lower false alarm rate and physically meaningful, that is, robust monitoring results.  相似文献   

2.
苏北农村主要水体氮磷污染及防治   总被引:2,自引:0,他引:2  
由于大量使用化肥及排放各类污水已造成苏经农村主要水体搂磷严重污染,并具有氮素富营养型及水文期变化特征。防治污染的方法是采用一些针对性措施对污染严重水域进行直接治理;加强监测,掌握污染动态,推广测土配方的施肥技术;加强对各类污水的治理。  相似文献   

3.
The monitoring of water quality today provides a great quantity of data consisting of the values of the parameters measured as a tunction of bme or as spatial function.In the marine environment, and especially in the suspended material, increasing importance is being given to the presence of particular pollution indices. With the increase in the number of sampling points, the amount of data increases and examining the results and their consequent interpretation becomes more difficult. To overcome such difficulties, numerous chemometric techniques have been introduced in environmental chemistry, such as Principal Component Analysis (PCA).The use of the PCA in this work has been applied to the analysis of twenty three different sampling points in three seasonal sampling cruises in the same year. This led to recognition of the influence and the localisation of wastewaters in the Augusta bay after measuring the water pollution parameters.The PCA made evident the difference between some sampling sites whose data were initially thought to be similar where the presence of hot industrial water discharge or urban wastewater determines the permanent water quality.Furthermore, it has allowed a choice of more significant parameters for monitoring programs and more representative sampling site locations.  相似文献   

4.
为追溯铁链厂生产废水总排口中检出氰化物的原因,从生产工艺、废水组成、废水处理工艺、所用物料以及分析方法等环节一一进行分析,最终发现氰化物是发黑工艺过程中物料发生化学反应而产生的,通过调整工艺路线,彻底解决了氰化物污染问题。  相似文献   

5.
No doubt, operator is one of the main fundaments in wastewater treatment plants. By identifying the inadequacies, the operator could be considered as an important key in treatment plant. Several methods are used for wastewater treatment that requires spending a lot of cost. However, all investments of treatment facilities are useable when the expected efficiency of the treatment plant was obtained. Using experienced operator, this goal is more easily accessible. In this research, the wastewater of an urban community contaminated with moderated, diluted and highly concentrated pollution has been treated using surface and deep aeration treatment method. Sampling of these pilots was performed during winter 2008 to summer 2009. The results indicate that all analyzed parameters were eliminated using activated sludge and surface aeration methods. However, in activated sludge and deep aeration methods in combination with suitable function of operator, more pollutants could be eliminated. Hence, existence of operator in wastewater treatment plants is the basic principle to achieve considered efficiency. Wastewater treatment system is not intelligent itself and that is the operator who can organize even an inefficient system by its continuous presence. The converse of this fact is also real. Despite the various units and appropriate design of wastewater treatment plant, without an operator, the studied process cannot be expected highly efficient. In places frequently affected by the shock of organic and hydraulic loads, the compensator tank is important to offset the wastewater treatment process. Finally, in regard to microbial parameters, existence of disinfection unit is very useful.  相似文献   

6.
There are various processes which can be used for wastewater treatment (WT), and the selection of the most sustainable one among different processes is a hard task. This study aims at helping the decision-makers (DM) to address this by developing an intuitionistic fuzzy set (IFS) theory based group multi-attribute decision analysis (MADA) method. Ten criteria in environment, economy, society-politic, and technology dimensions were employed to achieve sustainability measurement (SM) of WT processes. The multi-criteria sustainability assessment method developed in this study allow different experts to attend the SM, and enable the participants to employ the natural language/words to depict their intuitionistic opinions. Accordingly, the proposed method can achieve group SM under uncertainties. An illustrative case including four processes for wastewater treatment, namely Anaerobic-Anoxic-Oxic (AAO) process, Triple Oxidation Ditch (TOD) process, Anaerobic single-ditch oxidation (ASD) process, and Sequencing batch reactor activated sludge process (SBR), has been studied, and the results reveal that this method can determine sustainability sequence of different WT processes.  相似文献   

7.
The increasing number of potentially harmful pollutants in the wastewater effluent discharge necessitates the need for the development of fast and cost effective analytical techniques for extensive monitoring programmes to assess the effectiveness of the treatment process. This study compared the use of bacterial biosensors to the conventional Daphnia magna assay, Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD) tests as well as chemical analysis, for monitoring the toxicity of wastewater. The bacterial biosensors constructed in this study, using S. sonnei and E. coli, were found to be sensitive to the toxicity of the wastewater effluents. A linear increase in bioluminescence with increasing concentration of heavy metals and inorganic pollutants in water was observed, with a correlation coefficient (r(2)) as high as 0.995 and 0.997, respectively. No notable correlation between biosensor toxicity and BOD and COD test results was observed. These bacterial biosensors could provide appropriate alternatives for a rapid, sensitive and cost effective detection of wastewater quality. However, the differences in sensitivity obtained for the different systems suggest that the use of a battery of toxicity assays may be required to provide a real ecotoxicological assessment of wastewater samples.  相似文献   

8.
Stable nitrogen isotope ratios are routinely used to trace the dispersion and assimilation of wastewater-derived N in receiving environments, but few isotope studies have investigated wastewater treatment plants and ponds themselves. An improved understanding of N isotope compositions in effluent will help assess treatment plant processes and performance and will help trace sources of excess nutrients in receiving environments. Here, we assess N budgets and treatment processes in seven wastewater treatment plants and wastewater stabilisation ponds in northern Australia based on concentrations and isotope ratios of N in effluent. We show that δ15N values in effluent are linked to treatment type, effectiveness of conversion of ammonia and levels of gaseous N emissions. These relationships suggest that N isotope monitoring of wastewater treatment plants and ponds can provide an integrated assessment of treatment performance and gaseous N emissions on a pond- or plant-wide scale that is not readily available through other methods. Our findings further imply that monitoring N isotope ratios in receiving environments cannot be assumed to be universally effective as their sensitivity to uptake of wastewater-derived N will vary with the characteristics of individual treatment systems. Paradoxically, N isotope monitoring is less effective where treatment systems are functioning poorly and where monitoring needs are the greatest.  相似文献   

9.
The purpose of this study is to show the effectiveness of principle component analysis (PCA) as a method of alternatives analysis useful for improving the discussion of alternatives and public involvement. This study examined public consultations by applying quantitative text analysis (QTA) to the minutes of meetings and showed a positive correlation between the discussion of alternatives and the sense of public involvement. The discussion of alternatives may improve public involvement. A table of multiple criteria analysis for alternatives with detailed scores may exclude the public from involvement due to the general public's limited capacity to understand the mathematical algorithm and to process too much information. PCA allowed for the reduction of multiple criteria down to a small number of uncorrelated variables (principle components), a display of the merits and demerits of the alternatives, and potentially made the identification of preferable alternatives by the stakeholders easier. PCA is likely to enhance the discussion of alternatives and as a result, lead to improved public involvement.  相似文献   

10.
微生物应急监测是生态环境应急监测的重要组成部分,流动实验室在开展水质微生物指标应急监测方面存在一定的优势。在详细梳理微生物流动实验室在环境条件、硬件设施、设备物资、监测过程以及实验室管理等方面的各项要求的基础上,以北京市某地废水微生物应急监测为案例,列举了流动实验室在"人、机、料、法、环、测"等方面采取的措施和取得的效果。结果表明,建立微生物应急监测流动实验室既存在一定的必然性也存在可行性,并启发出能够满足质量管理要求的微生物应急监测流动实验室标准化建设思路。  相似文献   

11.
The analysis of heavy metals is very important for assessing the feasibility of the agricultural utilization for the municipal sludge. In this paper, a four-step sequential extraction method was applied to extract heavy metals (Cu, Zn, Mn, Cr, and Ni) in municipal sludges from seven individual wastewater treatment plants located in Jilin and Heilongjiang Province, China, for estimating the mobility and bioavailability of the metal ions in the agricultural application. The total concentrations of heavy metals and their chemical fractions after the sequential extraction were determined. Principal component analysis (PCA) was applied to analyze the relations of heavy metals fractions in the municipal sludges. Experimental results indicated that the total concentrations of Cu, Zn, Cr, and Ni in all sludge samples were below the threshold values set out by the Chinese legislation (GB18918-2002). Specially, Zn had a high bioavailability and mobility, Cu and Cr had potential bioavailability, while Mn mainly existed in the residual fraction of municipal sludge. On the other hand, Ni had different mobility in different municipal sludge. PCA results were confirmed by the environmental behavior of heavy metals.  相似文献   

12.
Insufficient wastewater remediation in small communities and nonpoint source pollution are the key factors in determining the water quality of small streams in an agricultural landscape. Despite the current extensive construction of municipal wastewater treatment facilities in small communities, the level of organic substances and nutrients in the recipient catchments has not decreased in many areas. This paper analyzes the changes in the water quality of the small streams after the deployment of wastewater treatment plants that were designed to address sources of pollution from small municipalities. The analysis is based on the results from a water quality monitoring network in the small watersheds in the Czech Republic. Five rural catchments with one dominant municipal pollution source, where a wastewater treatment plant was deployed during the monitoring period, were selected according to a predefined set of criteria, from a series of 317 profiles. Basic water quality indicators were selected for the assessment: O2, BOD-5, COD, TOC, conductivity, NH4-N, NO2-N, NO3-N, PT, and PO4-P. Results of the analysis showed that the simple deployment of the water treatment facilities at these streams often did not lead to a reduction of contamination in the streams. The expected post-deployment changes, namely, a significant and permanent reduction of stream contamination, occurred only in one catchment, whereas in the remainder of the catchments, only marginal changes or even increased concentrations of the contaminants were detected. As the critical factors that determined the efficiency of wastewater treatment were studied, the need for the consideration of the local conditions during the design of the facility, particularly regarding the size of the catchments, initial level of contamination, proper system of operation, and process optimization of the treatment facility, emerged as the important factor.  相似文献   

13.
针对废水治理工程验收监测存在的问题,提出了制定监测方案,建立企业污染设施管理制度和验收监测与污染监督监测相结合等具体解决问题的办法,确立为企业服务的思想。  相似文献   

14.
High resolution gas chromatography - mass spectrometry (GC-MS) has been widely used in the field of environmental sample analysis for volatile organic compounds (VOCs) (Gryder-Boutet, et al., 1988). Such a technique was applied to the analysis of VOCs at a local municipal wastewater treatment plant. The combination of purge and trap sample preparation and thermal desorption with cryofocusing technology, allows for the detection of a wide range of volatiles in wastewater and sludge samples. Results show that a large variety of organics present in samples are aliphatic and aromatic hydrocarbons. Their concentrations are in part per billion levels between 10 to 150 g/L. Others identified using this method are chlorinated hydrocarbons, sulfides and organic acids. By comparing the chromatograms of different wastewater and sludge samples collected from various treatment process units, it can be seen that most volatiles were removed or degraded after the aeration or digestion process. Information that provides an insight to the measurement of organic compounds in sludges is also discussed in this paper.  相似文献   

15.
为了研究生物急性监测方法对监测典型化工污水处理厂废水的适用性,选择2家常州市典型的化工园区污水处理厂("常A"和"常B"),进行了发光细菌、藻类、大型溞和斑马鱼卵4种不同层次受试生物的急性毒性检测。研究表明,发光细菌急性毒性、藻类叶绿素荧光毒性在2个污水处理厂中均被检测到,发光细菌急性毒性通常进水大于出水,但在投放大量氧化消毒剂时,出水表现出剧毒。藻类叶绿素荧光毒性最高值出现在常B进水中。大型溞和斑马鱼卵急性毒性仅在常B进出水样中有检出,受纳河道下游水样虽未表现出急性毒性,但可观察到斑马鱼卵各类发育畸形。4种生物急性毒性检测方法中,发光细菌适用范围最广,藻类、大型溞和斑马鱼卵急性毒性方法可根据监测目的和工业园区特点相应选择。实验结论可为化工污水处理厂尾水排放过程中生物毒性监测的常态化提供方法选择,为管理部门制定排放标准提供依据。  相似文献   

16.
A biochemical oxygen demand (BOD) monitoring system, based on electrochemically-active bacteria in combination with a microbial fuel cell, has been developed for the purpose of on-site, on-line and real-time monitoring of practical wastewater. A microbial fuel cell that had been enriched with electrochemically-active bacteria was used as the basis of the measurement system. When synthetic wastewater was fed to the system, the current generation pattern and its Coulombic yield were found to be dependent on the BOD5 of the synthetic wastewater. A linear correlation between the Coulombic yields and the BOD5 of the synthetic wastewater were established. Real wastewater obtained from a sewage treatment plant also produced a highly linear correlation between the Coulombic yield and BOD5 in the system. To examine on-site, on-line and real-time monitoring capability, the BOD monitoring system was installed at a sewage treatment plant. Over 60 days, the measurement system was successfully operated with high accuracy and good stability with the measuring period for a sample being 45 min. This application showed that the application of the measurement system was a rapid and practical way for the determination of BOD5 in water industries.  相似文献   

17.
生物监测可以系统反映污染物对生物生长的影响及其在生物体内的转化和迁移,在水环境监测与生态健康管理中的重要性日益突出。伴随着工业化的快速发展,中国水环境污染问题依然严峻,工业废水治理和排放问题仍旧突出。为进一步保障工业废水出水及受纳水体水质安全,迫切需要在工业废水监测中引入生物监测技术。对传统微生物群落监测法、水生生物毒性监测法和基于分子生物学技术的微生群落监测法等在工业废水监测领域的研究及应用进行了综述,并对存在的问题进行了总结。建议后续进一步完善工业废水生物监测体系时,参考国外成熟经验,制定出符合国内需求及特征的工业废水生物监测方法与评价标准,以便更好地掌握工业区整体环境健康及污染状况。  相似文献   

18.
洋河下游农灌区农作物受灾与水质污染的关系   总被引:4,自引:0,他引:4  
根据情况调查设计严密而合乎逻辑的监测方案:在农灌水质标准缺乏的情况下,根据监测数据和有关资料找出致害污染物;对本次监测数据和历年常规监测数据进行分析,确定污染源;最后提出防治污染的对策。结论是致死污染物为阿特拉津和乙草胺.而高锰酸盐指数、pH和悬浮物的超标是致害的重要有关因素;致害污染物主要来源了宣化区废水;严格监控农药厂废水、兴建污水处理厂和改善农灌措施是防治污染的途径。后来的事实完全证实了本结论和对策的正确性。  相似文献   

19.
水中汞监测存在的问题与解决办法   总被引:4,自引:0,他引:4  
利用中日合作 (JICA)项目资金 ,对测定地表水中汞存在的主要问题 ,如水样的保存和处理 ,水样的消解 ,测汞的冷原子吸收法和原子荧光法等进行了研究。通过对 33个环境监测站的样品考核 ,发现测定结果与标准值相比 ,偏高的数据达 75 %以上。提出了用 1%H2 SO4 和 0 1%K2 Cr2 O7保存水样最好 ;高锰酸钾 -过硫酸钾消解法适用于消解含有机物、悬浮物和组成复杂的废水样 ,高锰酸钾 -硫酸消解法适用于消解被有机物轻度污染的废水 ,溴酸钾 -溴化钾消解法适用于消解地表水和含较少有机物的生活污水及工业废水。研究表明 :尤以硫酸 -高锰酸钾 -过硫酸钾消解体系消解地表水和废水效果良好。对冷原子吸收法和原子荧光法中影响汞测定的因素 ,如空白值高、干扰物的消除、载气种类和流量、反应瓶体积和气液比以及反应时间等提出了详尽的解决方法  相似文献   

20.
This study was conducted to biologically treat wastewater discharged from the textile industry (textiles made of cotton and/or synthetic fiber) using sequencing batch reactor (SBR) technology (activated sludge process operating on batch mode). To achieve the objectives of the study, the characteristics of textile wastewater and the biodegradation of its organic constituents under unsteady state conditions were studied. Then, a bench-scale pilot plant was used to study the performance of SBR by monitoring the settleability and change in the constituents (chemical oxygen demand and solids) over time. Results of the study showed that textile wastewater has different types of pollutants: heat, basicity, suspended solids, organic and inorganic matter, and heavy metals. The factors affecting the biodegradation of organic matter were determined as the reaction time and the ratio of initial substrate to sludge concentrations. Also, removal of solids was monitored, and the settling velocity as affected by sludge concentration was graphically presented to enable the determination of settling time. Finally, the outcome of this study was used to suggest a procedure for the design of a full-scale SBR unit for treatment of textile wastewater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏