首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A passive sampler has been developed and is demonstrated in situ for urban runoff. The passive sampler is compared to conventional composite (time-dependent and flow-weighted) bottle sampling during and between storm events. The sampling was carried out at established stormwater stations; before and after a stormwater detention pond. In situ deployment of the passive sampler provides the metal concentrations, corresponding to the electrochemically available fraction of total metal, for time-dependent samples collected in parallel. The sampler provides improved accuracy compared to bottle sampling because contamination during sample transport and handling is minimised. Laboratory handling is reduced by direct analysis of the accumulated metals on the receiving membrane by laser ablation inductively coupled plasma mass spectrometry. Passive sampling also solves the problem of metal speciation change during transport to the laboratory, which is a potential problem for bottle samples. The low cost and convenience of the passive sampler and subsequent analysis should allow significantly more extensive spatial and temporal monitoring of metals in the aquatic environment than has previously been possible.  相似文献   

2.
博物馆室内微环境中碱性气体的被动采样方法研究   总被引:1,自引:1,他引:0       下载免费PDF全文
针对博物馆微环境中的碱性污染气体-氨气,采用自行研制的被动采样器,建立了一套适合博物馆馆藏文物保存环境中氨气含量分析的被动采样-离子色谱检测方法,应用于博物馆的实地采样分析,通过与主动法采样对照,获得了被动采样器在博物馆微环境中氨的吸收系数,从而获得采样点空气中氨气的浓度,为博物馆文物保存环境监测提供了可行方法。  相似文献   

3.
被动式个体采样器在环境监测中的应用   总被引:1,自引:0,他引:1  
本文报道了用被动式个体采样器监测空气小常见污染物NO2,SO2.提出了样品测定之前对每种污染物的具体实验要求。对济南市有关场所空气进行了监测。总结了个体采样器的优点。  相似文献   

4.
This work aimed to evaluate whether the performance of passive sampling devices in measuring time-weighted average (TWA) concentrations supports their application in regulatory monitoring of trace metals in surface waters, such as for the European Union's Water Framework Directive (WFD). The ability of the Chemcatcher and the diffusive gradient in thin film (DGT) device sampler to provide comparable TWA concentrations of Cd, Cu, Ni, Pb and Zn was tested through consecutive and overlapping deployments (7-28 days) in the River Meuse (The Netherlands). In order to evaluate the consistency of these TWA labile metal concentrations, these were assessed against total and filtered concentrations measured at relatively high frequencies by two teams using standard monitoring procedures, and metal species predicted by equilibrium speciation modeling using Visual MINTEQ. For Cd and Zn, the concentrations obtained with filtered water samples and the passive sampling devices were generally similar. The samplers consistently underestimated filtered concentrations of Cu and Ni, in agreement with their respective predicted speciation. For Pb, a small labile fraction was mainly responsible for low sampler accumulation and hence high measurement uncertainty. While only the high frequency of spot sampling procedures enabled the observation of higher Cd concentrations during the first 14 days, consecutive DGT deployments were able to detect it and provide a reasonable estimate of ambient concentrations. The range of concentrations measured by spot and passive sampling, for exposures up to 28 days, demonstrated that both modes of monitoring were equally reliable. Passive sampling provides information that cannot be obtained by a realistic spot sampling frequency and this may impact on the ability to detect trends and assess monitoring data against environmental quality standards when concentrations fluctuate.  相似文献   

5.
A new all season passive sampling system for monitoring O3 in the atmosphere has been developed in the laboratory and validated in the field. The unique features for this system include a newly designed passive sampler and a rain shelter, which allow the passive sampler to be installed in the field facing downwards. An equation associated with meteorological parameters is used to calculate the passive sampling rates. This system has been extensively tested in the lab (temperature from –18 to 20°C, relative humidity from 13 to 81%, and wind speed from 0.5 to 150 cm/s) and validated in the field in climates of all seasons. The accuracy of the ozone concentrations in the atmosphere obtained with the use of the new passive sampling system was higher than 85% compared to those obtained with continuous ozone analyzers. The new ozone passive sampling system can be used to measure ambient O3 concentrations ranging from 3 ppb to 1000 ppb based on one-day exposure and 0.1 ppb to 140 ppb for a monthly exposure period. It is also reasonable to conclude that the new passive sampling system can be used for eight-hour exposure study because of the low field blanks and high sampling rates.  相似文献   

6.
Two types of passive sampler were developed for the long-term monitoring of semivolatile organic compounds (SOCs) in air. They consist of poly(dimethylsiloxane) (PDMS)-coated stir bars (type A) or silicone tubing (type B), acting as a solid receiving medium, enclosed in a heat-sealed low-density polyethylene (LDPE) membrane. These samplers combine the advantages of integrative passive sampling with those of analysing accumulated analytes by thermodesorption-GC-MS, whilst avoiding the use of solvents and expensive sample preparation and cleanup steps. The performance of these samplers was investigated for the integrative sampling of SOCs, including alpha- and gamma-hexachlorocyclohexanes, hexachlorobenzene, 2,4,4'-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl and fluoranthene, in laboratory exposure experiments under controlled conditions. For both types of sampler, the uptake of all the analytes investigated was linear over an exposure period of 15 days. The sampling rates calculated ranged from 70 to 320 ml h(-1) (sampler A) and 630 to 4300 ml h(-1) (sampler B). The passive samplers are able to detect low time-weighted average air concentrations in the pg m(-3) range. The small, robust and inexpensive sampling devices were tested successfully for the long-term air monitoring of semivolatile organic pollutants in a polluted area over an exposure period of up to 28 days.  相似文献   

7.
被动采样监测环境空气中SO 2和NO 2   总被引:1,自引:0,他引:1  
用自主研制的采样管开展环境空气中SO2和NO2的被动采样监测.结果表明,被动采样监测结果与自动监测结果高度相关,经回归方程修正后,两者的结果没有显著性差异,被动采样的采样和分析产生的误差得以消除.  相似文献   

8.
This study presents the chemical composition of dry deposition by using dry deposition plate and water surfaces sampler during daytime and nighttime sampling periods at a near highway traffic sampling site. In addition, the characterization for mass and water soluble species of total suspended particulate (TSP), PM2.5 and PM10 were also studied at this sampling site during August 22 to October 31 of 2006 around central Taiwan. The samples collected were analyzed by using Ion Chromatography (DIONEX 100) for the ionic species analysis. Results of the particulate dry deposition fluxes are higher in the water surfaces sampler than that of the dry deposition plate. In other words, the results also indicated that water surface can absorb more ambient dry deposition inorganic pollutants than that of dry deposition plate in this study. The results obtained in this study indicated that the ionic species of Cl(-), NO3(-) and SO4(2-) occupied about average 60-70% downward flux out of total ionic species for either dry deposition plate or water surfaces sampler during August to October of 2006 at this near highway traffic sampling site.  相似文献   

9.
广州市空气可吸入性颗粒物的污染水平   总被引:10,自引:1,他引:9  
报告了中美合作“广州市大气污染对儿童肺功能影响研究”课题可吸入性颗粒物的两年监测结果。用安德森双道采样器、Teflon膜采集细颗粒物(<25μm,PM25)和粗颗粒物(25≤<10μm,PM2510),两者之和为PM10,每季度采15天,每天采一个24小时样品。结果表明,广州市城区大气可吸入性颗粒物的污染相当严重,尤其是细颗粒物(PM25)的污染,应引起公众和政府有关部门的重视。  相似文献   

10.
This study compares the ambient air particulate matter (PM10) data of 15 different coal mine environments. For most of these mine environments, the monitoring was carried out by different researchers using respirable dust sampler (RDS) that separates PM10 by centrifugal inertial separation. At two sites — Padmapur and Ghugus (Chandrapur, Maharashtra, India) — mass inertial impaction-based sampler was used for PM10 monitoring. It is observed that the spatiotemporal average value of ambient air PM10 monitored using mass inertial impactor reports relatively higher values (240–372 μg/m3) compared to those monitored using RDS (<227 μg/m3). In order to realize the severity of mine area pollution, it is compared with PM10 values found in an urban area (Delhi, India). It is found that PM10 values in Delhi (using mass inertial impactor) are much higher (300–400 μg/m3) than those reported for the mine environment. The data seems to indicate that the mine environment is relatively cleaner than urban air and therefore raises doubt about the appropriateness of using either mass impactor or RDS for PM10 sampling.  相似文献   

11.
A system, based on annular gold-coated denuders, was optimized and used in the atmospheric sampling of mercury in urban and rural sites of the Alta Floresta, a region in the Brazilian Amazon. Results showed that vapour phase mercury (Hgv) is dominant in samples collected in both sites. However, particulate mercury (Hg) may sometimes be significant at the urban site, with values representing up to 77% of the total Hg collected during sampling, but may also be insignificant at the same site, depending on the gold commercialization activity and, probably, on the meteorological conditions during the sampling period. The presence of mercury in both the vapour and particulate phases in the atmosphere of the urban site can explain the high mercury concentrations found in urban dust reported for some cities in the Amazon, and also the relatively high Hg concentrations found in soils adjacent to the urban centre of Alta Floresta. It appears that the urban dust of "garimpo" areas in the Amazon can act as an efficient adsorber of Hgv emitted by gold dealer operations during the purification process. Mercury emissions from gold dealer shops in the Amazon have been considered as a human health risk through the inhalation of Hg vapour. However, although true for indoor sites, the significant contribution of particulate phase Hg shown in this study in outdoor urban sites calls for a re-evaluation of the risk assessment estimates performed up to now in urban centres in the Amazon.  相似文献   

12.
A cellulose acetate membrane, positioned in a passive sampler system, was coated with the perfluorinated polymer Nafion. Aqueous metal transport through the membrane and the Nafion film was investigated. The Nafion-coated membrane prevents the transport of metals bound to natural organic material to the receiving phase in the passive sampler, while copper associated with small synthetic ligands pass through the Nafion film. Increasing thickness of the Nafion film decreases the metal uptake rate to the receiving phase in the passive sampler and increases the response time. A decreased response time for the passive sampler would provide a better estimation of rapid changes in concentration, particularly for dynamic aquatic systems such as urban runoff. Limited biofouling protection with the Nafion coating was demonstrated by growth inhibition of natural periphyton communities on glass surfaces.  相似文献   

13.
Ambient ammonia concentrations, mainly originating from agricultural activities, have increased in the last few decades in Europe. As a consequence, critical loads on oligotrophic ecosystems such as forests and mires are greatly exceeded. Monitoring of ambient ammonia concentrations is necessary in order to investigate source-receptor relationships. Measuring ambient ammonia concentrations continuously with high time resolution is very expensive and cost-efficient systems are required. Where time resolution is of minor importance, several cost-effective systems, mainly dry denuder and passive samplers, can be applied. In this paper the Zürcher passive sampler, a diffusive sampling system, is presented. It is a Palmes type sampler with an acidic solution as absorbent and is easy to handle. It was tested at 46 sites in Switzerland over one year. The average concentration in ambient air was 2.5 microg m(-3) +/- 0.4 microg m(-3). The average of the blank values were 0.21 microg m(-3). The detection limit (double the standard deviation of the blank values) was 0.36 microg m(-3). Three passive samplers were exposed at each site and each period. The mean standard deviation of these triplicate measurements was 9.5%. Compared with a discontinuous tubular denuder system and a continuous annular denuder system, the deviation was less than 10%. The Zürcher passive sampler is a useful and cost-efficient tool to determine long-term average ammonia concentrations (one- to four-week periods) in ambient air for mean concentrations above 1 microg m(-3).  相似文献   

14.
The development of convenient and competitive devices and methods for monitoring of organic pollutants in the aquatic environment is of increasing interest. An integrative passive sampling system has been developed which consists of a solid poly(dimethylsiloxane) (PDMS) material (tube or rod), acting as hydrophobic organic receiving phase, enclosed in a water-filled or an air-filled low-density polyethylene (LDPE) membrane tubing. These samplers enable the direct analysis of the pollutants accumulated during exposure in the receiving phase by thermodesorption-GC/MS, avoiding expensive sample preparation and cleanups. The capabilities of these sampling devices were studied for the sampling of 20 persistent organic pollutants (chlorobenzenes, hexachlorocyclohexanes, p,p'-DDE, PAHs, and PCBs) in laboratory exposure experiments. For the three sampler designs investigated the uptake of all target analytes was integrative over exposure periods up to 9 days (except PCB 101). The determined sampling rates range from 4 to 1340 microl h(-1) for the water-filled samplers and from 20 to 6360 microl h(-1) for the air-filled ones, respectively. The sampling rate of the analytes is dependent on their molecular weight, partition between water and sampler media (PDMS, polyethylene, water, air) and also of the sampler design. The passive samplers enable the estimation of time-weighted average (TWA) concentration of water pollutants in the lower ng l(-1) to pg l(-1) range.  相似文献   

15.
A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.  相似文献   

16.
总结了半透膜被动采样器(SPMDs)、极性有机化合物整合采样器(POCIS)、化学捕收器(Chemcatcher)和硅橡胶被动采样器(Silicon rubber)几种常用被动采样器的结构组成、应用模型、原理、样品的前处理、影响因素及应用范围,指出几种被动采样技术应用上存在的问题,并对其应用前景进行总结和展望。  相似文献   

17.
Bioaerosol sampling by a personal rotating cup sampler CIP 10-M   总被引:1,自引:0,他引:1  
High concentrations of bioaerosols containing bacterial, fungal and biotoxinic matter are encountered in many workplaces, e.g. solid waste treatment plants, waste water treatment plants and sewage networks. A personal bioaerosol sampler, the CIP 10-M (M-microbiologic), has been developed to measure worker exposure to airborne biological agents. This sampler is battery operated; it is light and easy to wear and offers full work shift autonomy. It can sample much higher concentrations than biological impactors and limits the mechanical stress on the microorganisms. Biological particles are collected in 2 ml of liquid medium inside a rotating cup fitted with radial vanes to maintain an air flow rate of 10 l min(-1) at a rotational speed of approximately 7,000 rpm. The rotating cup is made of sterilisable material. The sampled particles follow a helicoidal trajectory as they are pushed to the surface of the liquid by centrifugal force, which creates a thin vertical liquid layer. Sterile water or another collecting liquid can be used. Three particle size selectors allow health-related aerosol fractions to be sampled according to international conventions. The sampled microbiological particles can be easily recovered for counting, incubation or further biochemical analysis, e.g., for airborne endotoxins. Its physical sampling efficiency was laboratory tested and field trials were carried out in industrial waste management conditions. The results indicate satisfactory collection efficiency, whilst experimental application has demonstrated the usefulness of the CIP 10-M personal sampler for individual bioaerosol exposure monitoring.  相似文献   

18.
The performance of an integrative passive sampler that consists of a C18 Empore disk sorbent receiving phase fitted with low density polyethylene membrane was optimised for the measurement of time-weighted average concentrations of hydrophobic micropollutants in water. A substantial improvement of sampling characteristics including the rate of sampling and the sampling precision was achieved by decreasing the internal sampler resistance to mass transfer of hydrophobic organic chemicals. This was achieved by adding a small volume of n-octanol, a solvent with high permeability (solubility [times] diffusivity) for target analytes, to the interstial space between the receiving sorbent phase and the polyethylene diffusion-limiting membrane.  相似文献   

19.
A new type of directional passive air sampler (DPAS) is described for collecting particulate matter (PM) in ambient air. The prototype sampler has a non-rotating circular sampling tray that is divided into covered angular channels, whose ends are open to winds from sectors covering the surrounding 360°. Wind-blown PM from different directions enters relevant wind-facing channels, and is retained there in collecting pools containing various sampling media. Information on source direction and type can be obtained by examining the distribution of PM between channels. Wind tunnel tests show that external wind velocities are at least halved over an extended area of the collecting pools, encouraging PM to settle from the air stream. Internal and external wind velocities are well-correlated over an external velocity range of 2.0-10.0 m s?1, which suggests it may be possible to relate collected amounts of PM simply to ambient concentrations and wind velocities. Measurements of internal wind velocities in different channels show that velocities decrease from the upwind channel round to the downwind channel, so that the sampler effectively resolves wind directions. Computational fluid dynamics (CFD) analyses were performed on a computer-generated model of the sampler for a range of external wind velocities; the results of these analyses were consistent with those from the wind tunnel. Further wind tunnel tests were undertaken using different artificial particulates in order to assess the collection performance of the sampler in practice. These tests confirmed that the sampler can resolve the directions of sources, by collecting particulates preferentially in source-facing channels.  相似文献   

20.
本文采用扩散法将空气中氨采集在磷酸———甘油浸渍的无纺布吸收层上。该法采样速率为1376±84ml/min,与动力采样法现场对比测定,总不确定度为±193%,。采样器体积小,无噪声,操作方便,适于个体接触量与室内空气污染监测  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号