首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A diffusive sampling method for determination of methyl isocyanate in air has been developed. A glass fibre filter impregnated with 1-(2-methoxyphenyl)piperazine in a commercially available diffusive sampling device was used to collect methyl isocyanate and the derivative formed was analysed with LC-MS/MS. The sampling rate was determined to be 15.6 ml min(-1), with a relative standard deviation of 7.3%. The sampler was validated for sampling periods from 15 min to 8 h, for relative humidities from 20% to 80% and for concentrations from I to 46 microg m(-3). A field validation was also made and the diffusive sampling results showed no difference compared to a pumped reference method. The impregnated filters have to be stored apart from the diffusive sampler housing and loaded into the sampler prior to each sampling.  相似文献   

2.
A diffusive sampling method for the determination of methyl isocyanate (MIC) in air is introduced. MIC is collected using a glass fiber filter impregnated with 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ). The urea derivative formed is desorbed from the filter with acetonitrile and analyzed by means of high-performance liquid chromatography (HPLC) using fluorescence detection (FLD) with lambdaex = 471 nm and lambdaex = 540 nm. Additionally, a method was developed using tandem mass spectrometric (MS-MS) detection, which was performed as selected reaction monitoring (SRM) on the transition [MIC-NBDPZ + H]+ (m/z 307) to [NBDPZ + H]+ (m/z 250). The diffusive sampler was tested with MIC concentrations between 1 and 35 microg m(-3). The sampling periods varied from 15 min to 8 h, and the relative humidity (RH) was set from 20% up to 80%. The sampling rate for all 15 min experiments was determined to be 15.0 mL min(-1) (using HPLC-FLD) with a relative standard deviation of 9.9% for 56 experiments. At 80% RH, only 15 min sampling gave acceptable results. Further experiments revealed that humidity did not affect the MIC derivative but the reagent on the filter prior to and during sampling. The sampling rate for all experiments (including long term sampling) performed at 20% RH was found to be 15.0 mL min(-1) with a relative standard deviation of 6.3% (N = 42). The limit of quantification was 3 microg m(-3) (LC-MS-MS: 1.3 microg m(-3)) for 15 min sampling periods and 0.2 microg m(-3) (LC-MS-MS: 0.15 microg m(-3)) for 8 h sampling runs applying fluorescence detection.  相似文献   

3.
In the field of industrial hygiene, besides the necessity of monitoring phosphine with direct reading apparatus to prevent accidents, there is a need for a method of sampling and analysing phosphine to control workers' exposure. The use of filters impregnated with silver nitrate to collect arsine, phosphine and stibine in workplace air has been described in the literature. Having previously chosen this type of filter to collect arsine, we studied its characteristics for phosphine capture. A filter impregnated with sodium carbonate was used both as a prefilter to collect the particles and to trap arsenic trioxide. After dissolving the silver compounds in nitric acid, ICP emission spectrometry was used to carry out the analysis. This article describes the comparative sampling we performed in a microelectronic laboratory and in a fumigation chamber (130 samples) to determine the concentration of AgNO3 impregnation solution to be used, the detection limit of the method and the retention capacity of the impregnated filters. Interference with other gases reacting with silver nitrate was studied and the storage time for sampled filters and analysis solutions was checked. The detection limit of the adopted method is better than 1 microg per filter, and the retention capacity exceeds 300 microg per filter. The problem of how to sample phosphine when H2S, NH3, or HCl is present has been solved, but the problem of sampling phosphine in atmospheres where acetylene evolves remains. Sampled filters and filter solutions are stable for more than three months at ambient temperature.  相似文献   

4.
Hexahydrophthalic anhydride (HHPA) and methylhexahydrophthalic anhydride (MHHPA) are two highly allergenic compounds used in the chemical industry. A method was developed for quantification of protein adducts of HHPA and MHHPA in human plasma. The plasma was dialysed and the anhydrides were hydrolysed from the proteins at mild acidic conditions. The released hexahydrophthalic acid (HHP acid) and methylhexahydrophthalic acid (MHHP acid) were purified by reversed solid phase extraction followed by derivatisation with pentafluorobenzyl bromide. The derivatives were analysed using GC-MS in negative ion chemical ionisation mode with ammonia as moderating gas. As internal standards, deuterium labelled HHP and MHHP acids were used. The detection limits were 0.06 pmol mL(-1) plasma for HHP acid and 0.03 pmol mL(-1) plasma for MHHP acid. The between-day precisions for HHP acid were 18% at 0.3 pmol mL(-1) and 8% at 4 pmol mL(-1). For MHHP acid, the precisions were 13% at 0.3 pmol mL(-1) and 9% at 4 pmol mL(-1). There were strong correlations (r=0.94 for HHPA and 0.99 for MHHPA) between total plasma protein adduct concentrations and serum albumin adduct levels. Workers exposed to time-weighted average air levels of HHPA between < 1 and 340 microg m(-3) and between 2 and 160 microg m(-3) for MHHPA had plasma adduct levels between the detection limits of the methods and 8.40 and 19.0 pmol mL(-1), respectively.  相似文献   

5.
Personal and area air samples were taken at a scrap lead smelter operation in a bullet manufacturing facility. Samples were taken using the 37-mm styrene-acrylonitrile closed-face filter cassette (CFC, the current US standard device for lead sampling), the 37-mm GSP or "cone" sampler, the 25-mm Institute of Occupational Medicine (IOM) inhalable sampler, and the 25-mm Button sampler (developed at the University of Cincinnati). Polyvinylchloride filters were used for sampling. The filters were pre- and post-weighed, and analyzed for lead content using a field-portable X-ray fluorescence (XRF) analyzer. The filters were then extracted with dilute nitric acid in an ultrasonic extraction bath and the solutions were analyzed by inductively coupled plasma optical emission spectroscopy. The 25-mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37-mm filters. The single reading from the 25-mm filters was adjusted for the nominal area of the filter to obtain the mass loading, while the three readings from the 37-mm filters were inserted into two different algorithms for calculating the mass loadings, and the algorithms were compared. The IOM sampler was designed for material collected in the body of the sampler to be part of the collected sample as well as that on the filter. Therefore, the IOM sampler cassettes were rinsed separately to determine if wall-loss corrections were necessary. All four samplers gave very good correlations between the two analytical methods above the limit of detection of the XRF procedure. The limit of detection for the 25-mm filters (5 microg) was lower than for the 37-mm filters (10 microg). The percentage of XRF results that were within 25% of the corresponding ICP results was evaluated. In addition, the bias from linear regression was estimated. Linear regression for the Button sampler and the IOM sampler using single readings and the GSP using all tested techniques for total filter loading gave acceptable XRF readings at loadings equivalent to sampling at the OSHA 8-hour Action Level and Permissible Exposure Limit. However, the CFC only had acceptable results when the center reading corrected for filter area was used, which was surprising, and may be a result of a limited data set. In addition to linear regression, simple estimation of bias indicated reasonable agreements between XRF and ICP results for single XRF readings on the Button sampler filters, (82% of the individual results within criterion), and on the IOM sampler filters (77% or 61%--see text), and on the GSP sampler filters using the OSHA algorithm (78%). As a result of this pilot project, all three samplers were considered suitable for inclusion in further field research studies.  相似文献   

6.
Development of a field method for measuring manganese in welding fume   总被引:1,自引:0,他引:1  
Workers who perform routine welding tasks are potentially exposed to fume that may contain manganese. Manganese may cause respiratory problems and is implicated in causing the occurrence of Parkinson-like symptoms. In this study, a field colorimetric method for extracting and measuring manganese in welding fume was developed. The method uses ultrasonic extraction with an acidic hydrogen peroxide solution to extract welding fume collected on polyvinyl chloride filters. Commercially available pre-packaged reagents are used to produce a colored solution, created by a reaction of manganese(ii) with 1-(2-pyridylazo)-2-naphthol. Absorbance measurements are then made using a portable spectrophotometer. The method detection limit and limit of quantification (LOQ) were 5.2 microg filter(-1) and 17 microg filter(-1), respectively, with a dynamic range up to 400 microg filter(-1). When the results are above the LOQ for the colorimetric method, the manganese masses are equivalent to those measured by the International Organization for Standardization Method 15202-2, which employs a strong acid digestion and analysis using inductively coupled plasma-optical emission spectrometry.  相似文献   

7.
In this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling took place under flow-controlled conditions. Aerosols were extracted from the filters with water, in defined conditions, and the water-soluble fraction was quantified by ion chromatography (IC) for the determination of inorganic anions (Cl?, NO3 ? and SO4 2?). Equivalent sampling through the various channels was validated. Validation was based on the metrological compatibility of the content results for the various filters. Ion masses are metrologically equivalent when their absolute difference is smaller than the respective expanded uncertainty. When this condition is verified, the studied multifold device produces equivalent samples.  相似文献   

8.
The thermal degradation products of polyurethanes (PURs) and exposure to isocyanates were studied by stationary and personal measurements in five different occupational environments. Isocyanates were collected on glass fibre filters impregnated with 1-(2-methoxyphenyl)piperazine (2MP) and in impingers containing n-dibutylamine (DBA) in toluene. connected to a glass fibre postfilter. The derivatives formed were analysed by liquid chromatography: 2MP derivatives with UV and electrochemical detection and DBA derivatives with mass spectrometric detection. The release of aldehydes and other volatile organic compounds into the air was also studied. In a comparison of the two sampling methods, the 2MP method yielded about 20% lower concentrations for 4,4'-methylenediphenyl diisocyanate (MDI) than did the DBA method. In car repair shops, the median concentration of diisocyanates (given as NCO groups) in the breathing zone was 1.1 microg NCO m(-3) during grinding and 0.3 microg NCO m(-3) during welding, with highest concentrations of 1.7 and 16 pg NCO m(-3), respectively. High concentrations of MDI, up to 25 and 19 microg NCO m(-3), respectively, were also measured in the breathing zone during welding of district heating pipes and turning of a PUR-coated metal cylinder. During installation of PUR-coated floor covering, small amounts of aliphatic diisocyanates were detected in the air. A small-molecular monoisocyanate, methyl isocyanate, and isocyanic acid were detected only during welding and turning operations. The diisocyanate concentrations were in general higher near the emission source than in the workers' breathing zone. A sampling strategy to evaluate the risk of exposure to isocyanates is presented.  相似文献   

9.
Passive sampling of glycol ethers and their acetates in indoor air   总被引:1,自引:0,他引:1  
This study examined the performances of a thermal desorbable radial diffusive sampler for the weekly measurement of eight glycol ethers in indoor air and described the results of an application of this method carried out as part of HABIT'AIR Nord - Pas de Calais program for the air monitoring of these compounds in sixty homes located in northern France. The target compounds were the four glycol ethers banned from sale to the public in France since the 1990s (i.e. 2-methoxy ethanol, 2-ethoxy ethanol and their acetates) and four other glycol ethers derivatives of which the use have increased considerably (i.e. 1-methoxy-2-propanol, 2-butoxy ethanol and their acetates).A test program was carried out with the aim of validating the passive sampling method. It allowed the estimation of all the parameters of a method for each compound (calibration, analytical precision, desorption efficiency, sampling rate in standard conditions, detection limit and stability of sample before and after exposure), the examination of the influence of environmental factors on the sampling rate by some exposure chamber experiments and the assessment of the uncertainty of the measurements.The results of this evaluation demonstrated that the method has turned out to be suitable for six out of eight glycol ethers tested. The effect of the environmental factors on the sampling rates was the main source of measurement uncertainty. The measurements done in sixty homes revealed a relative abundance of 1-methoxy-2-propanol that was found in more than two thirds of homes at concentration levels of 4.5 microg m(-3) on average (a maximum value of 28 microg m(-3)). 1-methoxy-2-propanol acetate and 2-butoxy ethanol were also detected, but less frequently (in 19% of homes) and with the concentrations below 12 microg m(-3). The highest levels of these glycol ethers appear to be in relation to the emissions occurring at the time of cleaning tasks.  相似文献   

10.
Methods to monitor contamination of workplaces with antineoplastic drugs have been developed and validated. Cyclophosphamide (CP) was used as a model compound as it is one of the most commonly used antineoplastic drugs. A wipe sampling method to detect contamination with CP at surfaces was developed. A personal air sampling method to sample gas and vapour on solid sorbent tubes and particles with filters was also developed. Wipe and filter samples were extracted and sorbent samples were eluted, all with ethyl acetate. The samples were analysed with liquid chromatography tandem mass spectrometry. (2)H(6)-labelled cyclophosphamide was used as an internal standard. The between-day precision was 2-5% for wipe samples, 4-6% for sorbent samples and 3-8% for filter samples. The limit of detection was 0.02 ng CP per sample for the wipe and filter methods and 0.03 ng CP per sample for the solid sorbent method. Wipe sampling on surfaces made of different materials resulted in mean recoveries between 78-106%. The desorption recovery was between 97-102% for the wipe samples, 97% for the sorbent samples and 101% for the filter samples. Samples were stable for up to 2 months at 5 degrees C and -20 degrees C and for about 2 d at room temperature. The developed methods were applied to the measurement of contamination with CP in a hospital pharmacy. Trace amounts of CP, 1.3 and 1.4 ng, were detected on surfaces in the pharmacy.  相似文献   

11.
Monitoring of the workplace concentration of 3-methoxybutyl acetate (MBA), which is used in printer's ink and thinner for screen-printing and as an organic solvent to dissolve various resins, is important for health reasons. An active and a diffusive sampling method, using a gas chromatograph equipped with a flame ionization detector, were developed for the determination of MBA in workplace air. For the active sampling method using an activated charcoal tube, the overall desorption efficiency was 101%, the overall recovery was 104%, and the recovery after 8 days of storage in a refrigerator was more than 90%. For the diffusive sampling method using the 3M 3500 organic vapor monitor, the MBA sampling rate was 19.89 cm(3) min(-1). The linear range was from 0.01 to 96.00 microg ml(-1), with a correlation coefficient of 0.999, and the detection limits of the active and diffusive samplers were 0.04 and 0.07 microg sample(-1), respectively. The geometric mean of stationary sampling and personal sampling in a screen-printing factory were 12.61 and 16.52 ppm, respectively, indicating that both methods can be used to measure MBA in workplace air.  相似文献   

12.
Hereafter, an assessment of the ability of the chemiluminescence method to measure ambient NO2 with an accuracy within 15%, as requested by the data quality objective of European directive 1999/30/CE, is presented. In general, uncertainty is evaluated using the response to reference materials or by means of inter-comparisons used to determine some statistics like repeatability, reproducibility and calibration bias. These are incomplete approaches and the method of the Guide to the Expression of Uncertainty in Measurement, advised by the Directive, should be preferred. In fact, even if it requires a large data set, it allows the relative influence of all possible sources of uncertainty to be studied. The extent of NO2 uncertainty is mainly dependent on the level of NO. It is decreased by NOx and the correlation between NOx and NO. Furthermore, the uncertainty budget reveals that the contribution of accuracy of calibration standard, linearity, converter efficiency and drift of the analyser between calibration checks to the overall uncertainty is less important than the contribution of interference, mainly humidity and PAN in rural areas. The relative expanded uncertainty of the NO2 hourly average exceeds 30% for NO2 concentrations lower than 40 microg m(-3). Nevertheless, the data quality objective of 15% is reached for 200 microg m(-3), the hourly limit value of the European directive. On the contrary, at the limit value on the annual average, 40 microg m(-3), the data quality objective is not met if NO is higher than 100 microg m(-3). However, the data quality objective could be reached by correcting the measurements with the bias due to interference.  相似文献   

13.
Solid-phase microextraction (SPME) coupled with GC-MS has been used to monitor the degradation of polycyclic aromatic hydrocarbons (PAHs) by ultrasound treatment. Immersion SPME sampling enabled the fast and solventless extraction of target contaminants at the low microg l(-1) concentration level. The developed protocol was found to be linear in the concentration range from 0.1 to 50 microg l(-1) for most target analytes, with the limits of detection ranging between 0.01 and 0.70 microg l(-1) and the relative standard deviations between 4.31 and 27%. The developed SPME protocol was used to follow concentration profiles of aqueous solutions containing 16 PAHs, which were subject to low frequency ultrasonic irradiation. At the conditions employed in this study (80 kHz of ultrasound frequency, 130 W l(-1) of applied electric power density, 30 microg l(-1) of initial concentration for each of the 16 PAHs), sonochemical treatment was found capable of destroying the lower molecular weight PAHs (naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene and pyrene) within 120-180 min of irradiation. The higher molecular weight PAHs were more recalcitrant to ultrasound treatment.  相似文献   

14.
Researchers at the National Institute for Occupational Safety and Health (NIOSH) have long used stationary tapered element oscillating microbalances (TEOMs) in laboratory settings. They have served to assess the mass concentration of laboratory-generated particulates in experimental dust chambers and they provide a reference method for comparison with other particulate-measuring instruments. Current NIOSH research is focused on further adapting TEOM technology as a wearable personal dust monitor (PDM) for coal mining occupations. This investigation's goal is to help identify, quantify, and provide means for resolving certain TEOM-related error. The present research investigated bias caused by thermal effects on filter assemblies. New filters used in the PDM for 8 h tests show an average positive bias of 25.5 microg, while similar tests of equivalent filters used in two 1400A model TEOMs show an average positive bias of 34.3 microg. The derived bias values allow correction of previously collected biased data. Also, pre-heating the filters for 24 h at 46 degrees C shows significant bias reduction, with PDM pre-heated filters subsequently averaging -3.3 microg and 1400A TEOM filters averaging 5.9 microg. On a single-point comparison to gravimetric sampling, a 25.5 microg bias is only significant at low mass loadings. At 2.5 mg, this bias represents a negligible 1% of the mass measurement. If ordinary linear regression is used, the bias is still insignificant. However, if the more valid weighted linear regression is used, it gives more weight to the smaller dependent variable values, which are more impacted by the bias. Consequently, what is 1% bias on a single high-mass value can translate into a larger bias percentage at high-mass values when performing a weighted regression on data that include a large number of low-mass values.  相似文献   

15.
The foundational idea for this project is that household faucet-mounted water filters may be used as bioforensic sampling devices to detect the extent of a potential bioagent release in domestic water supplies. An optimized eluent solution was determined experimentally by quantifying recoveries of microorganisms from point-of-use (POU) drinking water filters. The optimized extraction protocol was then used in mock bioagent release experiments to determine the feasibility of POU filters as bioforensic sampling devices. Bacillus atrophaeus spores, Escherichia coli and PP7 virus were exposed to filters and the number of attached organisms was determined by enumerating the unattached organisms on selective agar media. Subsequently, the filters were eluted and the percent of extracted organisms was determined based on the number of attached organisms. Two popular brands of carbon block filters retained 92%-99% of representative virus, spore and vegetative bacteria. In back-flush elutions of single filters, the most efficient eluent was identified as a combination of 1% peptone and 1% Tween-80, and extraction recovered 25.4% (+/-17.5%) of attached E. coli, 20.4% (+/-3.6%) of B. atrophaeus spores, and 9.4% (+/-5.2%) of PP7 virions (+/- standard deviations). In bioagent release studies in which filters were challenged with 100 agents mL(-1), greater than 99% of the spores were retained by the filters, and the percent of attached spores that were recovered ranged from 10.4% at day 0 to 4.3% five days after the release event (averaged from five separate experiments). In contrast, E. coli, Salmonella typhimurium and PP7 virus were rapidly inactivated in the chlorinated tap water, indicating their improbable survival in chlorinated water supplies. It is therefore concluded that household water filters can be used as microbial sampling devices for bioforensic applications in the event of a bioagent release in domestic drinking water supplies.  相似文献   

16.
A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 microg m(-3) and 1248 microg m(-3) were determined to be 91.2 +/- 3.9 ml min(-1) and 111.6 +/- 2.8 ml min(-1), respectively. The acetic acid sampling rate was independent of the concentration in the range 160 microg m(-3)-1564 microg m(-3), and amounted to 97.3 +/- 3.1 ml min(-1). Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 3-21% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 +/- 0.07 microg for formic acid and 1.21 +/- 0.14 microg for acetic acid, and detection limits lower than 0.5 microg m(-3) could be achieved, which is an improvement of 98-99% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.  相似文献   

17.
Exposure to various chemicals can cause adverse effects to health, such as asthma and allergies, especially in children. Data on personal exposure levels in children are scarce, thus small lightweight diffusive mini-samplers for aldehydes and volatile organic compounds (VOCs) were designed to measure the exposure level of children to these chemicals. The aim of the study was to validate and examine the applicability of these mini-samplers for measuring daily chemical exposure. The diffusive mini-samplers are 20 mm in length, 11 mm in diameter, and 1.67 g in weight. The devices are cylindrically shaped with polytetrafluoroethylene membrane filters placed at each end. To measure aldehydes and acetone, 20 mg of 2,4-dinitrophenylhydrazine was used as an absorbent. To measure VOCs, a carbon molecular sieve was used. The sampling rate for each chemical was determined by parallel sampling with active samplers in a closed exposure bag. The blank levels of the chemicals and the storage stability of the device were tested. The mini-samplers were compared to commercially available diffusive samplers. To examine the applicability of the samplers, 65 elementary school children carried them for 24 h. The sampling rates for formaldehyde, acetaldehyde, and acetone were 20.9, 22.9, and 19.7 mL min(-1), respectively. The limits of quantification (LOQ) for the 24-hour sampling by high-performance liquid chromatography/ultraviolet (HPLC/UV) analysis were 8.3, 7.6, and 8.8 μg m(-3) for formaldehyde, acetaldehyde, and acetone, respectively. The sampling rates for the 11 VOCs were determined and ranged from 3.3 mL min(-1) for styrene and 2-ethyl-1-hexanol to 11.7 mL min(-1) for benzene. The LOQ for the 24-hour sampling by gas chromatography-mass spectrometry (GC-MS) analysis ranged from 5.9-105.2 μg m(-3), 1.1-24.7 parts per billion. The storage stability after 5 days ranged from 94.8 to 118.2%. Formaldehyde, acetone, benzene, and toluene were detected above the LOQ in more than 90% of the children, and the median concentrations were 21.7, 20.9, 10.1, and 21.5 μg m(-3), respectively. This study shows that the diffusive samplers developed were suitable for children to carry and were capable of measuring the children's daily chemical exposure.  相似文献   

18.
分析了COD在线分析仪和实验室比对结果人为差异的原因是样品不均匀,在线分析仪取样装置滤过,取样层面和采样方式以及沉淀消除的方法不同造成的.提出应在相同的地点、层面和同一容器取样,用相同沉淀消除方法去除样品中氯离子干扰,保证两方法比对中使用水样的一致均匀,使测试结果正确可信.  相似文献   

19.
通过对气相色谱-质谱联用法测定土壤中多溴联苯和多溴联苯醚类化合物含量的不确定度进行评定,分析了测量过程中引入的不确定度来源,求出各不确定度分量,最后合成标准不确定度并计算相对扩展不确定度。结果表明,各化合物最大的不确定度分量是方法回收率,约占50%~90%,方法相对扩展不确定度为0.12~0.20。  相似文献   

20.
A new simple, rapid selective and highly sensitive chromogenic reagent dibromo-p-methyl-carboxyazo (DBMCA) was synthesized and studied in detail for the spectrophotometric detection of lead. In 0.25 M phosphoric acid medium, which greatly increases the selectivity, Lead reacts with DBMCA to form a 1:2 blue complex having a sensitivity absorption peak at 646 nm. Under optimal conditions, Beer's Law is obeyed over the range from 0.09 to 0.8 microg mL(-1) Pb (II) and the apparent molar absorptivity is 1.03 x 10(5) mL(-1) cm(-1). The detection limit and the variation coefficient were found to be 2.12 microg mL(-1) and 1.0% respectively. It is found that, except for Ca (II) and Ba (II) all foreign ions studied do not interfere with detection. The interference caused by Ca (II) and Ba (II) can be easily eliminated by prior extraction with potassiumiodide-methylisobutylketone. The proposed method has been applied successfully for to the detection of Lead in vegetable leaves with good results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号