首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Users of automatic air pollution monitors are largely unaware of how certain parameters, like temperature, can affect readings. The present work examines the influence of temperature changes on chemiluminescence NO(x) measurements made with a Thermo Scientific 42i analyzer, a model widely used in air monitoring networks and air pollution studies. These changes are grouped into two categories according to European Standard EN 14211: (1) changes in the air surrounding the analyzers and (2) changes in the sampled air. First, the sensitivity tests described in Standard EN 14211 were performed to determine whether the analyzer performance was adapted to the requirements of the standard. The analyzer met the performance criteria of both tests; however, some differences were detected in readings with temperature changes even though the temperature compensator was on. Sample temperature changes were studied more deeply as they were the most critical (they cannot be controlled and differences of several tens of degrees can be present in a single day). Significant differences in readings were obtained when changing sample temperature; however, maximum deviations were around 3% for temperature ranges of 15°C. If other possible uncertainty contributions are controlled and temperature variations with respect to the calibration temperature are not higher than 15°C, the effect of temperature changes could be acceptable and no data correction should have to be applied.  相似文献   

2.
广西右江东笋断面溶解氧(DO)呈现5—11月浓度较低,12月及1—4月浓度较高的变化规律。从水温、藻类呼吸、沉积物耗氧、有机物耗氧、上游来水等方面分析了东笋断面低DO形成的原因。结果表明,5—11月东笋断面DO浓度较低,主要是受夏季高温和水利工程运行等非污染型因素的影响。右江流域夏秋季水温较高,限制了水体DO浓度的上限。热分层现象导致百色水库中层水体DO浓度较低,而水利枢纽发电时的下泄水正是中层水体,因此,下泄水DO浓度低是导致5—11月东笋断面DO浓度低的主要原因。东笋河段沉积物和有机物耗氧对DO浓度的影响很小,藻类呼吸作用对DO浓度的影响有限。  相似文献   

3.
于2018—2021年对南京市及国考断面七桥瓮进行水质调查,分析其溶解氧变化特征,采用水质水量联合评价及皮尔逊相关分析法,并结合水文气象等相关信息,对南京市地表水溶解氧分布特征及国考七桥瓮断面低氧成因进行研究分析。结果表明,南京市地表水溶解氧浓度夏季最低,中心主城区及附近区域溶解氧浓度均相对较低。七桥瓮断面溶解氧浓度在2.25~11.07 mg/L,其中5—9月溶解氧易出现超标波动。溶解氧浓度昼间高于夜间,与pH值呈正相关关系,与水温、高锰酸盐指数、氨氮、总磷均呈负相关关系。水温和上游来水带入的耗氧污染物是七桥瓮断面溶解氧偏低的主要成因,其中,溶解氧浓度与水温相关性最为显著。研究结论可为七桥瓮断面稳定达标提供基础支撑,为秦淮河流域精准治污提供技术依据,为南京市水环境多源同治提供治理思路。  相似文献   

4.
釜溪河为沱江一级支流,在自贡城区段设有国考碳研所断面。收集碳研所断面近10年来水质自动站数据,分析溶解氧(DO)变化特征,采样调查釜溪河自贡城区段水质及河道底泥污染状况,采用相关性分析、数值模拟等,研究分析釜溪河自贡城区段溶解氧分布特征及碳研所断面季节性低氧成因。研究结果表明,碳研所断面的溶解氧质量浓度变化特征呈现春末夏初最低,白天高晚上低的特征。釜溪河碳研所断面河水耗氧类污染物质量浓度较沱江流域内其他断面高,耗氧强度较大,溶解氧质量浓度较沱江流域其他断面偏低;其次,研究河段中釜溪河污水厂以下河段受污水厂低氧水排入和金子凼堰底层低氧水下泄影响,其溶解氧水平整体较污水厂以上河段低;最后,河段底泥有机质含量较高,春夏季气温升高将导致微生物分解活性增强大量消耗溶解氧,同时,闸坝和外来水体排入的水文扰动造成污水厂以下河段水温梯度弱,表层溶解氧易受底层低氧水影响,促使断面形成季节性低氧现象。溶解氧预测模型结果也进一步证实了温度变化和垂向温度梯度弱是碳研所断面溶解氧质量浓度季节性偏低的主要因素。  相似文献   

5.
The work describes the physicochemical analysis of the water samples collected from Lahore Canal to evaluate pollution load at different points of the canal. Different physical and chemical pollutants such as temperature, pH, electrical conductivity, total dissolved and suspended solids, turbidity, chlorides, sulphates, nitrates, oils and grease, dissolved oxygen, chemical oxygen demand and biological oxygen demand (BOD) were analysed. The data was analysed through analysis of variance, which showed that the p values for dissolved oxygen (DO), chemical oxygen demand (COD), BOD, electrical conductivity, total dissolved solid (TDS), total suspended solid (TSS), turbidity, oil and grease, sulphates, and nitrates are <0.05, while p value of temperature, pH, and chlorides are 1.000, 0.984, and 0.070, respectively, which are >0.05. Further regression analysis revealed that the simple line regression modal is fit for turbidity and TSS, electrical conductivity and TDS, COD and DO, BOD and DO, and BOD and COD. The studies reveal that Lahore Canal is receiving a considerable amount of physical and chemical pollutants at different points.  相似文献   

6.
Sediment oxygen demand (SOD) has become an integral part of modeling dissolved oxygen (DO) within surface water bodies. Because very few data on SOD are available, it is common for modeler to take SOD values from literature for use within DO models. SOD is such an important parameter in modeling DO that this approach may lead to erroneous results. This paper reported on developing an approach for monitoring sediment oxygen demand conducted with undisturbed sediment core samples, where the measured results were incorporated into a water quality model for simulating and assessing dissolved oxygen distribution in the Xindian River of northern Taiwan. The measured results indicate that a higher freshwater discharge results in a lower SOD. Throughout a 1-year observation in 2004, the measured SOD ranged from 0.367 to 1.246 g/m(2)/day at the temperature of 20°C. The mean values of the measured SOD at each station were adopted in a vertical two-dimensional water quality model to simulate the DO distribution along the Xindian River. The simulating results accurately depict the field-measured DO distribution during the low and high flow conditions. Model sensitivity analyses were also conducted with increasing and decreasing SOD values for the low and high flow conditions and revealed that SOD had a significant impact on the DO distribution along the Xindian River. The present work combined with field measurements and numerical simulation should assist in river water quality management.  相似文献   

7.
采用统计学方法对新疆某污水处理厂A2/O工艺进行进水水质数据分析,发现数据存在严重自相关现象,运用主成分消除法和岭回归消除法以消除自相关性。结果表明:TN和TP是污水厂提标改造的关键;碳源匮乏和缺氧区存在溶解氧(DO)是TN去除不佳的主要原因;适当提高污泥浓度(MLSS)和水力停留时间(HRT)是强化TP去除的措施;温度是影响脱氮除磷的主要因素。将温度模型与自相关磷模型相结合,可提高磷模型精度,有利于出水TP的预测。降低DO、增加外碳源,控制MLSS为3 500 mg/L~4 500 mg/L、HRT为5.4 h~8.0 h、厌氧区和好氧区DO为0.3 mg/L和2 mg/L、污泥龄(SRT)为11 d~12 d,可提升工艺脱氮除磷效果。  相似文献   

8.
Compared with sporadic conventional water sampling, continuous water-quality monitoring with optical sensors has improved our understanding of freshwater dynamics. The basic principle in photometric measurements is the incident light at a given wavelength that is either reflected, scattered, or transmitted in the body of water. Here, we discuss the transmittance measurements. The amount of transmittance is inversely proportional to the concentration of the substance measured. However, the transmittance is subject to interference, because it can be affected by factors other than the substance targeted in the water. In this study, interference with the UV/Vis sensor nitrate plus nitrite measurements caused by organic carbon was evaluated. Total or dissolved organic carbon as well as nitrate plus nitrite concentrations were measured in various boreal waters with two UV/Vis sensors (5-mm and 35-mm pathlengths), using conventional laboratory analysis results as references. Organic carbon increased the sensor nitrate plus nitrite results, not only in waters with high organic carbon concentrations, but also at the lower concentrations (< 10 mg C L?1) typical of boreal stream, river, and lake waters. Our results demonstrated that local calibration with multiple linear regression, including both nitrate plus nitrite and dissolved organic carbon, can correct the error caused by organic carbon. However, high-frequency optical sensors continue to be excellent tools for environmental monitoring when they are properly calibrated for the local water matrix.  相似文献   

9.
Load duration curves were developed using the Hydrological Simulation Program FORTRAN (HSPF) for dissolved oxygen (DO) for the Amite River in Louisiana, USA. The concept of ‘dissolved oxygen reserve’, defined as the total quantity of DO, is introduced. The effect of temporal resolution on duration curves of DO reserve was examined using duration curves developed based on daily, weekly, biweekly, and monthly average data. Duration curves for DO exhibited high variability in the load estimated using daily data as compared to those based on biweekly and monthly data. A seasonal analysis revealed the trend in the DO reserve. The daily DO reserve for the Amite River at Port Vincent was 44,049.31 kg when daily summer data were used and 74,255.15 kg for daily annual data. A surplus of 10,691 kg of DO reserve was shown in the monthly data during critical summer months. The coefficient of variation (CV), used to define the temporal scale-induced uncertainty, was found to be linearly and inversely correlated with the logarithm of the time scale. Regression equations were developed to extrapolate near real-time flow and water quality data, greatly simplifying flow and water quality monitoring and reducing the cost involved in flow and water quality monitoring.  相似文献   

10.
Portable X-ray fluorescence (XRF) technology may provide faster turn-around without compromising accuracy when assessing personal exposures to metals such as lead, but it has only been tested in limited field environments. This study is part of a series, where various types of sampler are used to collect airborne lead in different environments for presentation to a portable XRF analyzer. In this case personal samples were taken at a manufacturer of solder alloys consisting mainly of lead and tin, using the closed-face 37 mm cassette (CFC), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. Following XRF analysis the samples were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP). The internal surfaces of CFC's and 25 mm open-face cassettes were also wiped, and the wipes analyzed for lead to assess wall-losses in these two samplers. Analysis of all elements present is useful to ascertain contributions to matrix interference effects. In addition to lead, other metals such as tin, copper, iron, silver, cadmium and antimony were also detected in some or all of the samples by ICP analysis, but only copper and iron could be determined using the XRF analyzer under test. After the removal of a few outliers, all five samplers gave good correlations (r(2) > 0.9) between the two analytical methods over the entire range of found lead mass, which encompassed both the action level and the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations without additional correction, indicating an absence of matrix effects, particularly from tin, which was the most common element after lead. The average of three XRF readings across filters from the GSP samplers gave the best results with 96.7% of results within +/-25% and 100% within +/-30% of the associated ICP values. Using the center reading only was almost as good with 90.0% of results within +/-25% and 96.7% within +/-30% of the associated ICP values, and results can be obtained faster with a single reading. The use of an algorithm developed by OSHA for three readings from the CFC filter samples gave the next best results with 93.3% of XRF results within +/-25% of the corresponding ICP values. However, analysis of wipes from the interior of the cassettes indicated a substantial loss of sample to the walls, and even larger wall-losses were encountered in the 25 mm open-face cassette. Neither this latter sampler nor the IOM or button sampler met the 95% criterion, even for +/-30% accuracy.  相似文献   

11.
A framework for dissolved oxygen (DO) modeling of the Ravi River has been developed based on a combination of laboratory measurements and field and monitoring data. Both the classical Streeter-Phelps (CSP) and the modified Streeter-Phelps (MSP) models are used for DO simulations. The MSP model considers the carbonaceous biochemical oxygen demand (CBOD) and nitrogenous biochemical oxygen demand (NBOD) separately, whereas the CSP model is evaluated considering only the CBOD and NBOD is incorporated in the overall BOD utilization rate. CBOD, NBOD and BOD rates have been determined through long-term BOD analysis of five main wastewater outfalls and two surface drains discharging into the Ravi River over a 98 km stretch. Analysis by Thomas Method manifests strong coefficient of determination “R2” between 0.72 and 0.98 for all the three types of BOD rates. Sensitivity analyses have also been carried out to find out a suitable reaeration rate formula for highly variable flows in the Ravi River. The CSP model results based on classical approach of considering only CBOD show significant difference between the model predictions and field measurements suggesting that NBOD needs to be incorporated for the model development. The dissolved oxygen values calculated using the MSP model and the CSP model based on overall BOD rate are in close agreement with field measurements and are thus suitable to model DO levels in the Ravi River.  相似文献   

12.
In this study, we coupled a three-dimensional hydrodynamic model with an ecosystem model and applied it to the shallow complex floodplain wetland of Chini Lake in Malaysia. Our objective was to provide a better understanding of the lake’s ecosystem dynamics under different forcing mechanisms. Simulations and validation were performed over a dry month period. Wind speed ranged between 0 and 7.7 m s?1, whilst air temperature ranged between 22.0 and 35.6 °C. Advective transport driven by wind stress was the dominant physical force that shaped the water quality variations during the dry season. Convective circulation intermittently influenced the circulation during calm conditions. Nutrient concentration and stratification of dissolved oxygen (DO) varied between the lakes. Wind events saw patterns of the surface DO concentrations move spatially in the direction of the wind. The ecosystem model simulation suggested that the water quality in Chini Lake was influenced by macrophyte production, although the dissolved and particulate organic carbon accounted for the major fraction of organic matter content in the lake.  相似文献   

13.
This study is an assessment of the possible effects of the dredging project on the water quality of the surrounding environment. Water quality data for the Bonny offshore river were collected. The parameters assessed were temperature, dissolved oxygen (DO), pH, biochemical oxygen demand (BOD), total dissolved solids (TDS), total suspended solids (TSS), nitrogen as nitrate, and phosphate. The concentrations of TDS, TSS, and nitrate far exceeded the permissible standard. There were significant differences between the dry and rainy season values of BOD5, TDS, TSS, nitrate, and phosphate. Also, the sediment physicochemical analysis indicated the presence of heavy metals such as Pb, Fe, Cd, Zn, Cr, and elements such as Ca, K, and Na. Following an assessment of the potential impact of the project using interaction matrix and checklist questionnaires, results showed that the major physicochemical parameters influenced by dredging are DO, TDS, TSS, heavy metals and calcium, potassium, and sodium. Mitigation measures for eliminating or reducing the negative impacts of dredging are presented.  相似文献   

14.
Aerosol, NO and CO concentration, temperature, air humidity, air flow and number of running ventilation fans were measured by continuous analysers every minute for a whole week for six different one-week periods spread over ten months in 2001 and 2002 at measuring stations in the 7860 m long tunnel. The ventilation control system was mainly based on aerosol measurements taken by optical scatter sensors. The ventilation turned out to be satisfactory according to Norwegian air quality standards for road tunnels; however, there was some uncertainty concerning the NO2 levels. The air humidity and temperature inside the tunnel were highly influenced by the outside metrological conditions. Statistical models for NO concentration were developed and tested; correlations between predicted and measured NO were 0.81 for a partial least squares regression (PLS1) model based on CO and aerosol, and 0.77 for a linear regression model based only on aerosol. Hence, the ventilation control system should not solely be based on aerosol measurements. Since NO2 is the hazardous polluter, modelling NO2 concentration rather than NO should be preferred in any further optimising of the ventilation control.  相似文献   

15.
基于集合经验模态分解和支持向量机的溶解氧预测   总被引:1,自引:0,他引:1  
应用集合经验模态分解(EEMD)和支持向量机(SVM)相结合的方法,建立一种天然水体溶解氧浓度预测模型。首先,利用EEMD方法将溶解氧时序分解成不同频段的分量,以降低序列的非平稳性;然后,根据各序列分量的自身特征建立合适的SVM预测模型,此过程通过相关分析确定各分量输入量;最后,将各子分量预测值合成得到最终的预测结果。使用该模型对嘉陵江北温泉段的溶解氧浓度进行预测,结果表明,与传统单一的SVM和BP神经网络模型相比,该模型能有效提高预测精密度,具有良好的应用前景。  相似文献   

16.
For some utilities, new US drinking water regulations may require the removal of disinfection byproduct (DBP) precursor material as a means of minimizing DBP formation. The Environmental Protection Agency's Stage 1 DBP Rule relies on total organic carbon (TOC) concentrations as a measure of the effectiveness of treatment techniques for removing organic material that could act as DBP precursors. Accordingly, precise and accurate methods are needed for the determination of TOC and dissolved organic carbon (DOC) concentrations in raw and finished potable water supplies. This review describes the current analytical technologies and summarizes the key factors affecting measurement quality. It provides a look into the fundamental principles and workings of TOC analyzers. Current peroxydisulfuric acid wet ashing methods and combustion methods are discussed. Issues affecting quality control, such as non-zero blanks and preservation, are covered. Some of the difficulties in analyzing water for TOC and DOC that were identified up to 20 years ago still remain problematic today. Limitations in technology, reagent purity, operator skill and knowledge of natural organic matter (NOM) can preclude the level of precision and accuracy desirable for compliance monitoring.  相似文献   

17.
Water Quality Changes in Chini Lake, Pahang, West Malaysia   总被引:1,自引:0,他引:1  
A study of the water quality changes of Chini Lake was conducted for 12 months, which began in May 2004 and ended in April 2005. Fifteen sampling stations were selected representing the open water body in the lake. A total of 14 water quality parameters were measured and Malaysian Department of Environment Water Quality Index (DOE-WQI) was calculated and classified according to the Interim National Water Quality Standard, Malaysia (INWQS). The physical and chemical variables were temperature, dissolved oxygen (DO), conductivity, pH, total dissolved solid (TDS), turbidity, chlorophyll-a, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solid (TSS), ammonia-N, nitrate, phosphate and sulphate. Results show that base on Malaysian WQI, the water in Chini Lake is classified as class II, which is suitable for recreational activities and allows body contact. With respect to the Interim National Water Quality Standard (INWQS), temperature was within the normal range, conductivity, TSS, nitrate, sulphate and TDS are categorized under class I. Parameters for DO, pH, turbidity, BOD, COD and ammonia-N are categorized under class II. Comparison with eutrophic status indicates that chlorophyll-a concentration in the lake was in mesotrophic condition. In general water quality in Chini Lake varied temporally and spatially, and the most affected water quality parameters were TSS, turbidity, chlorophyll-a, sulphate, DO, ammonia-N, pH and conductivity.  相似文献   

18.
Dissolved Oxygen Conditions in Northern Gulf of Mexico Estuaries   总被引:6,自引:0,他引:6  
Because deficient dissolved oxygen (DO) levels may have severe detrimental effects on estuarine and marine life, DO has been widely used as an indicator of ecological conditions by environmental monitoring programs. The U.S. EPA's Environmental Monitoring and Assessment Program for Estuaries (EMAP-E) monitored DO conditions in the estuaries of the Gulf of Mexico from 1991 to 1994. DO was measured in two ways: 1) instantaneous profiles from the surface to the bottom were taken during the day, and 2) continuous measurements were taken near the bottom at 15 min intervals for at least 12 h. This information was summarized to assess the spatial distribution and severity of DO conditions in these estuaries. Depending on the criteria used to define hypoxia (DO concentrations usually <2 mg L-1 or <5 mg L-1) and the method by which DO is measured, we estimate that between 5.2 and 29.3% of the total estuarine area in the Louisianian Province was affected by low DO conditions.  相似文献   

19.
结晶紫-聚乙烯醇体系分光光度法测定水中溶解氧   总被引:1,自引:0,他引:1       下载免费PDF全文
在碘量法测定水中溶解氧的基础上,利用I3-与结晶紫在聚乙烯醇存在下结合成电中性的离子缔合物,以碘酸钾为标准溶液,与过量碘化钾反应生成碘,加入结晶紫后在550 nm处有最大吸收的原理测定水中溶解氧,优化了试验条件,考察了共存离子的干扰。方法在0.002 7 mg/L~0.55 mg/L范围内符合比尔定律,检出限为0.001 1 mg/L,蒸馏水平行测定的RSD≤0.2%,加标回收率为100%~101%,实际水样测定与碘量法和溶解氧测定仪结果一致。  相似文献   

20.
Lidar measurements of temperature for the upper troposphere and lower stratosphere are commonly derived by the Raman technique. Lidar signals derived from vibrational Raman processes have been subjected to numerous simulation tests to examine their sensitivity to the presence of aerosols and ozone in the atmosphere. The influence of aerosols characteristics (wavelength dependence of aerosol extinction and particle phase function) and of ozone concentration on Raman temperature profiles is estimated. Simulations indicate large temperature deviations for post-volcanic conditions. For a Raman backscatter at 607 nm, bias is below 1 K for a total optical depth less than 9 x 10(-3) in the case of a stratospheric contamination and less than 6 x 10(-3) for a tropospheric contamination. The effect of aerosols depends on phase function and a few parameters such as altitude, optical depth and the shape of the high-altitude cloud. The wavelength dependence of aerosol extinction has some influence only for severe post-volcanic conditions (Scattering Ratio, SR >2). For a Raman backscatter at 387 nm, bias is larger and can be significant even in background aerosol conditions. Changes in the ozone density profile lead to significant Raman temperature deviations only for some specific conditions. Results suggest that both aerosol and ozone corrections are necessary to obtain an accuracy better than the 1 K requested for most atmospheric applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏