首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
建立了采用液相色谱-串联质谱法(LC-MS/MS)同时测定污水中10种精神活性物质的分析方法。污水样品经甲酸与甲酸铵调节pH后,加入氘代内标混匀,离心并过滤膜后可直接上样分析。研究表明,在1~250 ng/L的线性范围内,10种精神活性物质的线性相关系数均大于0.992,定量限均低于0.5 ng/L。在3个加标水平下,10种精神活性物质的加标回收率为87.2%~114%,相对标准偏差为0.53%~3.60%(n=3)。将该方法应用于某区域10份生活污水样品的检测,在3份水样中检出吗啡、甲基苯丙胺、氯胺酮等精神活性物质,对应的质量浓度范围分别为3.41~9.55、0.90~1.63、1.06~1.78 ng/L。与经固相萃取前处理后的分析方法相比,该方法可在10 min内完成分离和检测的全过程,具有简单、快速、节约的优点,可用于污水样品中10种痕量水平精神活性物质的定量分析。  相似文献   

2.
高效液相色谱-串联质谱法测定废水中5种喹诺酮类抗生素   总被引:2,自引:0,他引:2  
建立高浓度有机废水中5种喹诺酮类抗生素的高效液相色谱-串联质谱测定方法。水样经HLB固相萃取小柱富集净化,12 ml甲醇洗脱、浓缩并加入内标溶液后,定容至1 mL待测。以C18柱为分离柱,含0.01%甲酸的甲醇-含0.01%甲酸的水溶液为流动相,目标物质在10 min内分离。在0.25~1 250 ng/mL范围内,目标物质线性关系良好(R20.99)。基质加标试验结果表明,纯水中的回收率为61.40%~91.92%,废水中的回收率为54.92%~101.87%,检出限为0.25~2.5 ng/L,方法定量限为0.36~3.99 ng/L。应用该方法对21家猪场的64份废水样品进行分析,5种喹诺酮类抗生素的检出频率为47%~95%,平均检出浓度为980~5 734 ng/L。该方法快速、准确,适用于高浓度有机废水中喹诺酮类抗生素的同时测定。  相似文献   

3.
A rugged and specific method based on tandem solid-phase extraction and liquid chromatography-tandem mass spectrometry for the determination of anti-infectives in raw sewage and wastewater plant effluents was developed. Analyte recoveries from spiked effluents ranged from 68 to 104%. Two specific selected reaction monitoring transitions and their peak area ratios were used to avoid false positives and confirm the presence of the targeted substances. Detection limits allowed low nanogram per litre detection (0.3-22 ng L(-1)). The method was successfully applied to real samples from the Montréal wastewater treatment plant. All the studied anti-infectives were found in the wastewater samples in concentrations ranging from 39 to 276 ng L(-1). Mean flows of anti-infectives were estimated from effluent concentrations and it was found that large amounts (>118 g day(-1) up to 830 g day(-1)) are discharged in the receiving waters of the St Lawrence River.  相似文献   

4.
A simple on-line method was developed for the analysis of pharmaceuticals, pesticides and some metabolites in drinking, surface and wastewater samples. The technique is based on the use of on-line solid-phase extraction combined with liquid chromatography electrospray tandem mass spectrometry with positive electrospray ionization (LC-ESI(PI)-MS/MS). The injection of only 1 mL of filtered water sample is used with a total analysis time of 20 min, including the period required to flush the SPE cartridge with organic solvent and reconditioning the LC column. Method detection limits were in the range of 2 to 24 ng L(-1) for the compounds of interest, with recoveries from 87 to 110% in surface as well as wastewater samples. Matrix effects were observed for some compounds without exceeding more than 25%. All results displayed a good degree of reproducibility, with relative standard deviations (RSD) of less than 12% for all compounds. Moreover, at least 200 samples were analyzed without altering the performance of the pre-concentration column. This method was preferred over traditional off-line procedures because it minimizes tedious sample preparation, increases productivity and sample throughput. The analysis of various water and wastewater samples showed that caffeine, carbamazepine and atrazine could be detected in all the samples analysed and the selected compounds are always present in at least one of the sample types.  相似文献   

5.
建立了一种利用吹扫捕集(PT)-气相色谱(GC)/火焰光度检测器(FPD)同时测定水中16种致嗅类有机硫化物的分析方法。研究并优化了捕集阱类型、吹扫温度、吹扫时间,解吸温度以及解吸时间对PT的影响。实验表明:大部分硫醚类和硫醇类化合物分别在1~100 ng/L和3~300 ng/L范围内线性良好,线性相关系数大于0.99;相对标准偏差小于9.47%(n=6);加标回收率为81.68%~115.18%。定量下限(10倍信噪比)范围从0.19 ng/L(二乙基二硫醚)到2.67 ng/L(2-甲基-1-丙硫醇)。采用此方法对北京市3条河流水样进行了检测,除1-丙基二硫醚和2-甲基-2-丙硫醇外,其他14种有机硫化物都有检出,质量浓度为1.95~1 282.35 ng/L。  相似文献   

6.
水体中磺胺、四环素、喹诺酮类抗生素检测方法   总被引:6,自引:2,他引:4  
建立了固相萃取-高效液相色谱-串联质谱法(SPE-HPLC-MS/MS)同时检测水体中3类15种抗生素的分析方法。水样用Oasis HLB固相萃取小柱净化富集。通过对比水样在不同pH条件下的回收率,优化了环境水样中抗生素固相萃取过程中的前处理条件。采用甲醇和0.1%甲酸溶液作为流动相,经过梯度洗脱进行分离,在HPLC-MS/MS多反应监测模式下进行定性定量分析。结果表明,环境水体中15种抗生素的检出限和定量下限分别为0.12~1.6 ng/L和0.2~3.0 ng/L,自来水加标回收率为34.9%~102.5%(pH=4)。用该方法对海河流域13个地表水水样进行了初步检测,结果表明,部分抗生素普遍存在于地表水体中。其中,磺胺甲基异NFDA1唑检出频率最高,在13个地表水样品中均有检出。  相似文献   

7.
This study quantifies the regional distribution of the micropollutant benzothiazole (BT) in river water by sampling 15 river sites in the Schwarzbach watershed (about 400 km(2)) from November 2008 to February 2010. Additionally, wastewater samples from three municipal wastewater treatment plants (WWTPs) in Germany were analyzed. BT was detected in all wastewater influent and effluent samples as well as in all river water samples collected downstream of wastewater discharge. This corroborates the ubiquitous occurrence of BT in the aqueous environment. Concentrations were between 58 and 856 ng L(-1) in the river water. The observed mean concentration at the outlet of the investigated catchment was 109 ng L(-1). With only a few exceptions, temporal and spatial variations of BT concentrations in river water were low. Rather similar BT concentrations over a wide range of river discharge indicate that dilution along the mainstream is negligible and, thus, supports the hypothesis that paved surface runoff during rain events is an important BT source not only for wastewater influent but also for river water. This was supported by detecting the highest BT concentrations at sampling locations close to the dense highway network around the city of Frankfurt. Since BT was also detected in river water collected from locations that were clearly unaffected by wastewater effluent discharge, surface runoff must be considered as a diffuse source of BT in river water.  相似文献   

8.
We describe a method for the simultaneous determination of eight kinds of phenylbenzotriazole-type mutagens (PBTA-1, -2, -3, -4, -5, -6, -7 and -8) in river water based on liquid chromatography-tandem mass spectrometry (LC/MS/MS). The application of dopant-assisted atmospheric pressure photoionization (APPI) for the detection of the PBTAs was studied. The APPI technique provided higher PBTA signal intensities than those obtained with an electrospray ionization (ESI) source, and the APPI method was used for the determination of the PBTAs. A solid-phase extraction procedure was used for the extractions of PBTA-1 through -8 from river water. The procedure was rapid and the relative standard deviations were below 15%. The detection limits of PBTA-1 through -8 in river water using the proposed method were found to range from 0.04 to 0.5 ng L(-1) and PBTAs were successfully detected in river water at sub-ng L(-1) levels.  相似文献   

9.
The occurrence of the metabolites of five human pharmaceuticals was investigated in treated wastewater, surface waters and sediments. Metabolites of carbamazepine (carbamazepine epoxide), diclofenac (4'- and 5-hydroxy diclofenac) and atorvastatin (o- and p-hydroxy atorvastatin) were typically detected in flow proportional 24 h composite samples of wastewater effluent collected from the Norwegian cities of Oslo and Troms? at higher concentrations than the parent pharmaceutical. The concentrations determined in discharged effluent were as high as 3700 ng L(-1) for 5-hydroxy diclofenac. The overall mean concentration of metabolites being typically higher in the primary treated effluent from the city of Troms? compared to the tertiary treatment performed on the Oslo effluent. Metabolites of carbamazepine (carbamazepine-10,11-epoxide), metoprolol (α-hydroxy metoprolol) and simvastatin (hydroxy simvastatin) were detected in surface water samples collected from Oslofjord at concentrations of up to 108 ng L(-1), whilst α-hydroxy metoprolol and simvastatin hydroxy carboxylic acid were also detected in sediments at low ng L(-1) concentrations. These screening data show that the metabolites of selected pharmaceuticals are being discharged into the Norwegian coastal environment and that certain metabolites occur in marine surface waters and sediments.  相似文献   

10.
A procedure using pre-column trimethylsilyl derivatization and gas chromatography/ mass spectrometry (GC/MS) was developed and applied in determining trace estrogens in complex matrix. Main conditions were optimized, including pH value, salinity of water sample, elution reagents, clean procedure, derivative solvent and temperature. The optimized method was used to determine steroid estrogens in surface water and effluents of wastewater treatment plant (WWTP). Low detection limits of 0.01, 0.03, 0.03, 0.07, 0.09 and 0.13 ng/l for DES, E1, E2, EE2, E3 and E(V), respectively were obtained under optimism condition. No apparent interferences appeared in chromatography in comparison with ultrapure water blank. Mean recovery ranged from 72.6% to 111.0% with relative standard deviation of 1.1-4.6% for spiked surface water, and from 66.6% to 121.1% with relative standard deviation of 1.5-4.7% for spiked effluent of WWTP. The results suggested that the optimized method provides a robust solution for the determination of trace steroid estrogens in complex matrix.  相似文献   

11.
顶空固相微萃取-气相色谱法测定水中四乙基铅   总被引:2,自引:1,他引:1  
建立了水中四乙基铅的测定方法——顶空固相微萃取-气相色谱法,探讨了影响水中四乙基铅萃取效率的温度、转速和萃取时间等因素。实验结果表明,在0.08~10μg/L范围内线性关系良好,方法检出限为0.02μg/L,实际水样加标回收率为96.2%~98.3%。  相似文献   

12.
Occurrence and behaviour of 4-nonylphenol in river water of Germany   总被引:1,自引:0,他引:1  
An analytical method composed of solid-phase-extraction (SPE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed to investigate the occurrence and the behaviour of the endocrine disruptor 4-nonylphenol (4-NP) in river water of Germany. 16 Para-isomers of the complex mixture of 4-NP isomers have been resolved in the SPE-extracts of river water samples. The mass spectra indicate the presence of four distinct groups of isomers. The different groups are characterised by different base peaks of the mass spectra dependent on the substitution of the alpha-carbon on the alkyl chain. The different isomers show (i) alpha-methyl, alpha-ethyl (base peak 149), (ii) alpha-dimethyl (base peak 135), (iii) alpha-methyl, alpha-propyl, alpha-butyl (base peak 121) and (iv) alpha-methyl, alpha-propyl, alpha-butyl (base peak 107) configuration of the alkyl chain. The recovery of the unbranched compound 4-n-NP was > or = 90%. Detection limit and determination limit of the whole analytical procedure were 6 ng L(-1) and 25 ng L(-1), respectively with a relative standard deviation of 11.7%. The concentration of the sum of the 4-NP isomers in all samples of river water ranged from 28 ng L(-1) (Elbe River) to 1220 ng L(-1)(Oder River). In a period of a higher river water level, a higher amount of 4-NP was detected in the Oder River than in a period of a lower water level. Therefore dilution was not the determinant factor of the 4-NP concentration in river water. The diurnal dynamics of the sewage treatment works (STWs) have to be considered as an influencing factor for the presence of 4-NP in river water.  相似文献   

13.
Capillary microextractor (CME) in combination with a gas chromatograph-mass spectrometer (GC-MS) was employed for the determination of trace priority hazardous substances in water. Three groups of semivolatile organic compounds (SVOCs), i.e., chlorinated hydrocarbons, pesticides and polycyclic aromatic hydrocarbons (PAHs), were simultaneously determined. SVOCs were extracted from 7 mL of water samples on a 100 cm commercial gas chromatographic column (0.32 mm id x film thickness 0.25 microm, HP-5 capillary column) and eluted with only 3 microL of acetonitrile. The extractant was analyzed by GC-MS in the selected ion monitoring mode. The method showed good linearity over the concentration range 10 ng L(-1) to 3.0 mg L(-1) with correlation coefficients (r) greater than 0.99 and low limits of detection ranged from 10 ng L(-1) to 1.0 mg L(-1). High recovery (more than 80%) was obtained with relative standard deviation less than 10%. The method was successfully applied for trace level analyses of SVOCs in water samples.  相似文献   

14.
A sensitive and accurate analytical method based on dispersive liquid-liquid microextraction was developed for the simultaneous determination of selected pesticides, hormones, and endocrine disruptors by GC-MS. The optimum conditions of the extraction procedure were determined using an experimental design of factors significantly affecting the extraction output. Analysis of variance (ANOVA) was used to evaluate the main effects of experimental factors and their interactions. The limit of detection values determined for the analytes under optimum experimental conditions were found to be between 0.30–2.0 ng/mL. The linear calibration plot of analytes span across a wide concentration range and low %RSD values from replicate measurements indicated good precision of the developed method. Spiked recovery tests were also performed on municipal wastewater, well water, lake water, sea water, and tap water matrices to determine the method’s accuracy and applicability to water samples. The recovery results obtained were satisfactory for all water samples.  相似文献   

15.
Environmental occurrence of CECs poses a great threat to both aquatic life and human health. The aim of this study was to optimize and validate SPE/LC-(ESI)MS-MS method for simultaneous quantitative monitoring of two sub-classes of CECs (pharmaceuticals and hormones) and to estimate the concentrations of select CECs in environmental water samples. For all the tested analytes, recoveries in laboratory reagent water were greater than 81%. Average percent (relative standard deviation) RSD of the analytes in recovery, repeatability, and reproducibility experiments were ≤?10%. Determination coefficients (r2) of primidone, diclofenac, testosterone, and progesterone were estimated to be 0.9979, 0.9972, 0.9968, and 0.9962, respectively. Limits of detection (LOD) for primidone, diclofenac, testosterone, and progesterone were 4.63 ng/L, 5.36 ng/L, 0.55 ng/L, and 0.88 ng/L, respectively. Limits of quantification (LOQ) for primidone, diclofenac, testosterone, and progesterone were 14.72 ng/L, 17.06 ng/L, 1.766 ng/L, and 2.813 ng/L, respectively. Average recoveries in environmental water and wastewater samples were greater than 74% and RSD were ≤?7%. Trace levels (68.33–125.70 ng/L) of primidone were detected in four environmental water samples, whereas diclofenac was not detected in any of the tested sample. Trace levels of progesterone were observed in two environmental samples (16.64 –203.73 ng/L), whereas testosterone was detected in STP inlet sample (178.16 ng/L).  相似文献   

16.
采用5-氯-2-(吡啶偶氮)-1,3-二氨基苯分光光度法测定水质钴。对分析方法的样品前处理、样品保存、样品分析条件、干扰消除、检出限及测定范围、实际样品测定进行了深入研究和技术改进。水样经消解后测定的方法检出限为0.009 mg/L,经富集后测定的方法检出限为4×10-4mg/L,干扰消除实验的回收率为96%~101%,地表水、地下水、生活污水及工业废水等4种类型水样的加标回收率为92%~103%。  相似文献   

17.
Antifouling biocides are used to prevent the settlement and growth of organisms on submerged surfaces. Irgarol 1051 is currently among the most widely used organic booster biocides worldwide. This study reports Irgarol 1051, its major metabolite M1 (aka GS26575), and diuron concentrations found in selected California marinas. Seasonal water samples (n = 46) were collected during the summer and fall of 2006 from eleven marinas throughout Southern and Northern California. The samples were extracted using solid phase extraction and analysed utilizing liquid chromatography tandem mass spectrometry (LC-MS-MS) with electrospray ionization. All three compounds were detected in all samples, representing a 100% frequency of occurrence and indicating widespread use around the sampled marinas. Irgarol concentrations ranged from 12 to 712 ng L(-1) (average 102 ng L(-1)), M1 concentrations were 1-217 ng L(-1) (average 31 ng L(-1)), and diuron concentrations were 5-27 ng L(-1) (average 13 ng L(-1)). In general, concentrations of both Irgarol (15-712 ng L(-1)) and M1 (1-217 ng L(-1)) were greater in samples collected during the summer, corresponding to the peak of the boating season. The detected diuron concentrations in most cases were greater for fall samples (7-27 ng L(-1)), and probably represented a combination of non-agricultural (rights of way) and agricultural applications of diuron in California. The maximum Irgarol concentration detected in California marinas in summer 2006 (712 ng L(-1)) was five times greater than the Irgarol concentration suggested as the plant toxicity benchmark (136 ng L(-1)). Twenty three percent of samples from California marinas in this study exceeded this benchmark, suggesting that detected Irgarol concentrations may be high enough to cause changes in phytoplankton communities in the sampled marinas.  相似文献   

18.
A new method has been developed for the determination of gold based on separation and preconcentration using silica gel modified with benzoylthiourea. The optimum experimental parameters for preconcentration of gold, such as acid concentration, sample flow rate, eluent and matrix ions, have been investigated. Gold could be quantitatively retained in the 0.25-2.0 mol L(-1) HCl and HNO(3) concentrations, and then eluted completely with 0.5 mol L(-1) thiourea in 1.0 mol L(-1) HCl. The sorption capacity of gold(III) is 0.92 +/- 0.04 mmol g(-1) with a high enrichment factor of 267. The relative standard deviation of the method, RSD%, was found as 1.2% for 0.1 microg mL(-1). The detection limit for gold was 1.4 microg L(-1). The validation of the proposed method was checked by the analysis of certified reference soil materials. The presented procedure was applied to the determination of gold in some environmental samples.  相似文献   

19.
建立了地表水中9种性激素的固相萃取-超高效液相色谱-串联质谱检测方法。利用HLB固相萃取柱富集水体中痕量性激素,用甲醇洗脱并浓缩,再以1 mmol/L氟化铵-乙腈为流动相,经C_(18)柱分离,采用电喷雾离子源、质谱多反应监测模式,内标法定量,实现了地表水中9种性激素的同时检测。方法检出限为0. 1~1. 8 ng/L,在低、中、高3个加标水平下,性激素的平均回收率为69. 6%~115. 0%,相对标准偏差为3. 2%~17. 7%。该方法灵敏度高,定性准确,操作简单高效,适用于地表水中9种性激素的定性定量分析。  相似文献   

20.
Simultaneous analysis of 11 free estrogen hormones and five conjugated estrogens in water and municipal wastewater was studied. The analytical method was developed and tested for different types of solid-phase extraction adsorbents, eluents, sample containers and storage conditions, derivatization, and matrix effects. Varian Bond Elut C-18 solid-phase extraction adsorbent cartridge was selected based on its high recoveries for both free and conjugated estrogens. Sample storage conditions, as well as selection and pretreatment of sample container materials, can affect the trace level analysis of estrogens. Silanization of glassware is observed to provide low relative standard deviation (RSD) in the analysis and less percentage loss due to contacting with sample container materials. Light exposure during the test can significantly impact the results. The derivatized samples stored at −20°C for at least 6 days showed less than 10.5% average RSD in the analysis. The recovery efficiency in clean water varies from 72% to 101% for free estrogens and 78% to 82% for conjugated estrogens. The method detection limits (MDL) for most of the compounds range from 30 to 870 ng/L using a sample volume of 200 mL. With a sample volume of 3 L, the most sensitive compound produces a MDL of 0.03 ng/L. Dilute methanol is used to wash the loaded cartridge as a cleanup step in order to remove interfering species during analysis of wastewater samples. Using the optimized analytical methods, the concentration level of free estrogens in the influent and effluent municipal wastewaters is tested.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号