首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Using previously established procedures that utilise linear free energy relationships, we estimated binding constants for the Windermere Humic Aqueous Model VII (WHAM/Model VII) for several radionuclide cations (Pd(2+), Sn(2+), U(4+), NpO(2)(2+), Pu(4+) and PuO(2)(2+)). This extends the number of cations that can be calculated with the model above the 40 included in the original Model VII work. When combined with equilibrium constants for inorganic species this allows the calculation of equilibrium distributions of chemical species under a wide range of conditions.  相似文献   

2.
为验证大气中SO2的浓度对气态H2O2自动荧光法监测的影响,设置了SO2与H2O2在自动荧光过氧化氢分析仪中的反应实验;同时,利用SO2和H2O2的反应速率公式进行了模拟计算,模拟计算结果与仪器的监测结果基本相符.证明了在大气SO2浓度较高的情况下,气态SO2对H2O2的自动荧光法测定确实会有显著影响,通过模拟计算的方法可对在线监测的H2O2浓度数据进行校正.  相似文献   

3.
水溶液中二氧化氯及系列氧化物的测定   总被引:7,自引:0,他引:7  
根据碘离子在不同pH值与ClO2、Cl2、ClO2-、ClO3-发生不同反应的原理,提出同时分析含氯系列氧化物的方法.相对标准偏差1.2%~6.5%,加标回收率可达92.6%~94.8%.该方法不仅可用于测定二氧化氯发生器产物各组分的浓度,还能用于测定给水和废水处理中的二氧化氯.  相似文献   

4.
Indoor NO2 concentrations were measured in the kitchen, the living room and bedroom of 612 houses in two different areas in the Netherlands. In a group of housewives living in these homes, personal exposure to NO2 was measured. NO2 concentrations indoors were dependent on the presence or absence of (un)vented gas appliances. Personal NO2 exposure was only different between the two areas in the group with the lowest indoor concentrations. In this study, it was determined that gas appliances inside the house are the most important factor with respect to NO2 exposure and that outside NO2 concentration played a secondary role, except in situations where gas appliances were absent.  相似文献   

5.
被动采样监测环境空气中SO 2和NO 2   总被引:1,自引:0,他引:1  
用自主研制的采样管开展环境空气中SO2和NO2的被动采样监测.结果表明,被动采样监测结果与自动监测结果高度相关,经回归方程修正后,两者的结果没有显著性差异,被动采样的采样和分析产生的误差得以消除.  相似文献   

6.
催化极谱法测定降水中微量过氧化氢   总被引:2,自引:0,他引:2  
在0.6mol/L磷酸介质中,钒5-Br-PADAP与H2O2形成三元络合物,于0.05V处产生一极灵敏的极谱波。过氧化氢浓度在0.06-17μg/25mL范围内,峰电流与其含量呈良好线性关系。  相似文献   

7.
废气中二氧化硫和硫化氢的气相色谱分析   总被引:1,自引:1,他引:1       下载免费PDF全文
试验了气相色谱法分离分析废气中高浓度二氧化硫和硫化氢的方法,用高分子多孔微球GDX 502为固定相,2m玻璃柱分离,火焰光度检测器检测,取得了分离效果好、峰形对称、分析速度快的测定效果。对色谱柱进行了选择,并讨论了柱管材质和担体对样品的吸附作用。  相似文献   

8.
Based on high spectral resolution infrared solar observations made at the International Scientific Station of the Jungfraujoch, Switzerland, total vertical column abundances of 18 atmospheric gases have been monitored routinely since 1984. The observed temporal evolutions in the columns of CH4, N2O, CO, CHClF2 (HCFC-22) and CF2Cl2 (CFC-12) are reported here as typical examples of this monitoring effort which is conducted within the frame of Global Change and Network for the Detection of Stratospheric Change programs.  相似文献   

9.
Effects of Cu2+, Pb2+ and Zn2+ were studied on voltage-activated Na-, Ca-, and K-currents in snail neurons. It was found that: 1. In normal physiological saline Cu2+, Pb2+ and Zn2+ ions exerted complex changes on the total ionic currents; 2. All three metal ion have depressed the inward Na-currents but with different K D , moreover Pb 2+ increased Na-current at low concentrations (5 M); 3. The inward Ca-current was also reduced. The sequence of the blocking effect of metals was different: Pb>Cu>Zn, however the steady-state inactivation was influenced only by Cu2+; 4. Outward currents were decreased in all neurons by Cu2+, but the effects of Pb2+ and Zn2+ were either depression or enhancement in different indentified neurons; 5. The possibility of binding heavy metals to wide variety of membrane proteins and the observed effects on different ionic channels suggest that the metal effect is complex and cannot be taken as a specific one to a single channel type or site of location.  相似文献   

10.
Arsenic is a widespread contaminant in the environment. The intake of water containing high concentrations of arsenic could have serious impact on human health, such as skin and lung cancer. In the European Union, thus, also in Italy, the arsenic limit in drinking water is 10 μg L?1. Several water remediation treatment technologies are available for arsenic removal. For some processes, the removal efficiencies can be improved after an oxidation step. Most full-scale applications are based on conventional oxidation processes for chemical micropollutant removal. However, if water contains arsenic and refractory organic contaminants, the advanced oxidation processes could be considered. The aim of this work was to investigate the effectiveness of ultraviolet (UV) radiation alone and in combination with hydrogen peroxide for the oxidation of arsenic and terbuthylazine (TBA). The experimental tests were performed in groundwater at the laboratory scale (0.1 mg L?1 As(III) and 10 μg L?1 TBA). Hydrogen peroxide alone (15 mg L?1) was ineffective on both arsenic and TBA oxidation; the 253.7-nm radiation alone did not oxidize arsenic(III), but photolyzed efficiently TBA (52 % removal yield at a UV dose of 1,200 mJ cm?2). The UV/H2O2 advanced oxidation (UV dose 600–2,000 mJ cm?2, 5–15 mg L?1 H2O2) was the most effective process for the oxidation of both arsenic and TBA, with observed oxidation efficiencies of 85 and 94 %, respectively, with 5 mg L?1 H2O2 and a UV dose of 2,000 mJ cm?2.  相似文献   

11.
针对MOBILE6.2预测天然气汽车排放因子的功能,分析了其在预测液化石油气(LPG)轻型汽车上的可行性。并根据LPG出租车汽车排放总量分析系统(VMAS)测试结果,得到所需参数,预测了实验车队的排放因子,与实测值的误差≤10%,表明MOBILE6.2预测LPG轻型汽车排放因子具有良好的适用性。  相似文献   

12.
The goal of this paper is to compare and evaluate the performance of three air quality regulatory models for mercury releases. The models include Industrial Source Complex Short Term model (ISCST2), Industrial Source Complex Long Term model (ISCLT2), and SCREEN2. The evaluation is conducted in multiple point source urban environment using meteorological data, emission inventory and monitoring data for eight stations for the year 1990 to 1992. The performance of the models is evaluated using eight statistical parameters. The comparison of models results for both quarterly and annual averaging periods shows that ISCST2 predictions qualitatively match the observed concentrations; whereas SCREEN2 predicts highest concentrations and ISCLT2 the lowest concentrations. The summary of statistical analysis obtained by using three different methods of observed concentration (Co) and predicted concentrations (Cp) comparison show that the ISCST2 has a better overall performance than ISCLT2 and SCREEN2 models. However, none of the models met the criteria for a reasonable model. Summaries of 95% confidence limits on normalize mean square error (NMSE), geometric mean variance (VG) and geometric mean bias (MG) for each and among model indicate that of the three models, ISCST2 has the best overall performance indicators. Improved model performance may be achieved by incorporating different types of mercury forms into emission rate and air dispersion calculations.  相似文献   

13.
A combined NO2-SO2 Radiello radial-type diffusive sampler was validated under controlled laboratory conditions and compared with NO2-SO2 results of 3 other type of samplers in a field comparison at two locations Ghent-Mariakerke and Borgerhout in Flanders. Laboratory exposures at different temperatures (-5, 10 and 30 degrees C) and relative humidities (0, 50 and 80% RH) in combination with varying concentration levels and exposure times were carried out, with a focus on extreme conditions. Concentration level and exposure time were changed together following suppliers linear working range of samplers and assuring absolute amounts of compounds on the sampler corresponding to those of environmental levels. The average uptake rate for NO2 for 24 hour exposures at 10 degrees C and 50% RH and tested concentration levels (+/-73, 146 and 293 ppb NO2) was 0.076 +/- 0.011 ng ppb(-1) min(-1). Uptake rates during all experiments were lower than the uptake rate given in the instruction manual of the sampler. A significant effect of temperature and relative humidity on NO2 uptake rate was observed. The temperature effect from 10 to 30 degrees C corresponds to the temperature effect given by the supplier of the samplers. High relative humidity (70 to 80%) caused a strong non-reproducible decrease of uptake rate for NO2 at 24 hour experiments but this effect was not observed at longer exposures except for the tests at -5 degrees C. At the tested temperature below zero in combination with high relative humidity the sampler showed anomalous behaviour for NO2. The possible effect of concentration level and exposure time for NO2 needs further research. The average uptake rate for SO2 calculated from all exposures is 0.478 +/- 0.075 ng of sulfate ion each ppb min of SO2 and accords to suppliers uptake rate. No clear effects of temperature, relative humidity or concentration level/exposure time on the uptake rate for SO2 were found, partly due to the large scatter of results. Although NO2 accuracy of Radiello samplers was better during field campaigns than during laboratory validation, IVL and OGAWA samplers gave better results for NO2. In the field, IVL samplers showed best agreement with the continuous analyzers for both NO2 and SO2.  相似文献   

14.
Textile industry wastes raise a great concern due to their strong coloration and toxicity. The objective of the present work was to characterize the degradation and mineralization of textile effluents by advanced oxidative processes using either TiO2 or TiO2/H2O2 and to monitor the toxicity of the products formed during 6-h irradiation in relation to that of the in natura effluent. The results demonstrated that the TiO2/H2O2 association was more efficient in the mineralization of textile effluents than TiO2, with high mineralized ion concentrations (NH 4 + , NO 3 ? , and SO 4 2? ) and significantly decreased organic matter ratios (represented by the chemical oxygen demand and total organic carbon). The toxicity of the degradation products after 4-h irradiation to Artemia salina L. was not significant (below 10 %). However, the TiO2/H2O2 association produced more toxicity under irradiation than the TiO2 system, which was attributed to the increased presence of oxidants in the first group. Comparatively, the photogenerated products of both TiO2 and the TiO2/H2O2 association were less toxic than the in natura effluent.  相似文献   

15.
用ICP—AES检测离子浓度方法研究了不同形态MnO2在不同pH下对污水中重金属离子Pb2+和Cd2+的吸附效果。结果表明:当溶液的pH=7时最有利于吸附,且α形态MnO2对重金属离子的吸附效果最好,其中对Pb2+最高吸附效率可达99.84%,对Cd2+的最高吸附效率可达71.54%。  相似文献   

16.
原煤二氯甲烷浸取液中多环芳烃分布特征   总被引:3,自引:0,他引:3  
本文用色谱/质谱/红外联用系统研究了原煤二氯甲烷浸取液中多环芳烃的种类、数量、含量及其分布特征。为进一步研究煤燃烧排放飞灰、烟气、炉渣中多环芳烃分布打下良好基础。  相似文献   

17.
采用高效液相色谱二极管阵列检测器同时测定化妆品中二苯酮-2、二苯酮-3与甲氧基肉桂酸乙基己酯,以乙腈和水为流动相梯度洗脱,335 nm为检测波长,以保留时间和紫外光谱特征定性,外标法定量。3种化合物在1.00 mg/L~150 mg/L范围内线性良好,最低检出质量分数均为0.015%,基质加标平均回收率为96.2%~117%,RSD为0.2%~1.0%。  相似文献   

18.
本文介绍了用被动式个体采样器同时测定空气中SO2和NO2的方法,吸收层用三乙醇胺(20%)+碳酸钠(5%)溶液浸渍的滤纸,采样后分成两等分,分别测定SO2和NO2浓度。与有动力的溶液吸收管现场对比验证,表明两者结果是一致的。在外环境监测时,为了克服风速的影响,可将被动式个体采样器放在TSP流量采样器的帽形采样头中,这样可同时测定环境空气中TSP、SO2和NO2。  相似文献   

19.
2-(2-吡啶偶氮)-间苯二酚固相萃取光度法测定镉的研究   总被引:1,自引:0,他引:1  
研究了用2-(2-吡啶偶氮)-间苯二酚(PAR)固相萃取光度法测定镉,在pH=8 0的硼酸-氢氧化钠缓冲介质中,TritonX-100存在下,QAMDHB与镉反应生成2∶1稳定络合物,体系最大吸收波长为520nm,摩尔吸光系数 =5 18×104L·mol-1·cm-1。样品中的镉用强阴离子交换固相萃取柱固相萃取预分离和富集后,用该方法测定,结果令人满意。  相似文献   

20.
测定环境大气悬浮颗粒物中痕量汞,用4种消化液进行对比实验,其中高锰酸钾─硫酸─过硫酸钾混合液消化效果较好,用冷原子荧光测定操作简便,检测下限为0.05μg/L,重复测定9个实际样品,相对标准偏差为11.6%,变异系数为10.4%,添加汞标准回收率为102%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号