首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
对南通市2016年12月-2018年10月大气污染季节分布特征进行了分析。结果表明,南通市ρ(PM2.5)和ρ(水溶性离子)为冬、春季高,夏、秋季低。春夏秋冬四季ρ(水溶性离子)占ρ(PM2.5)百分比分别为68.2%,70.6%,64.5%和74.5%,其中二次离子SNA(NO3-、SO42-和NH4+)占ρ(PM2.5)的百分比分别为63.1%,67.0%,59.3%和66.8%;ρ(NO3-)/ρ(SO42-)表明,移动源已成为南通市春、秋、冬季的主要污染源,四季均存在不同程度的二次转化,且SO2的转化率均大于NO2,NO2冬季转化率最大、夏季最小,SO2夏季转化率最大、秋季最小。南通市NO2转化为硝酸盐的主要形式是气相均相反应,非均相反应和均相反应对SO2转化为硫酸盐的贡献差异不大。  相似文献   

2.
A study for assessment and management of air quality was carried out in the Ib Valley area of the Ib Valley coalfield in Orissa state, India. The 24 h average concentrations of suspended particulate matter (SPM), respirable particulate matter (RPM), sulfur dioxide (SO(2)) and oxides of nitrogen (NO(x)) were determined at regular intervals throughout one year at twelve monitoring stations in residential areas and six monitoring stations in mining/industrial areas. The 24 h average SPM and RPM concentrations were 124.6-390.3 microg m(-3) and 25.9-119.9 microg m(-3) in residential areas, and were 146.3-845.2 microg m(-3) and 45.5-290.5 microg m(-3) in industrial areas. During the study period, 24 h and annual average SPM and RPM concentrations exceeded the respective standards set in the Indian national ambient air quality standard (NAAQS) protocol as well as USEPA, EU, WHO and World Bank standards at most of the residential and industrial areas. However, concentrations of SO(2)(annual average: 24.6-36.1 microg m(-3) and 24 h average: 17.0-46.3 microg m(-3)) and NO(x)(annual average: 23.6-40.9 microg m(-3) and 24 h average: 18.3-53.6 microg m(-3)) were well within the prescribed limit of the NAAQS and international standards in both residential and industrial areas. The temporal variations of SPM and RPM fitted polynomial trends well and on average in the mining area 31.91% of the SPM was RPM. The linear regression correlation coefficients between SPM and RPM and between NO(x) and SO(2) were 0.94 (+/-0.04) and 0.66 (+/-0.10), respectively. The optimum interpolation technique, kriging, determined that maximal concentrations of SPM and RPM occurred within the mining site. Highest concentrations of particulate matter were observed during the winter season followed by summer, autumn and rainy seasons. An action plan is formulated for effective control of air pollution at source, and mitigative measures should include implementation of green belts around the sensitive areas where the concentration of air pollutants exceeds the standard limit.  相似文献   

3.
A major Irish study, based upon more than 8000 samples collected over the measurement period of 22 years, for sulfur dioxide (SO2-S), sulfate (SO4-S) and nitrogen dioxide (NO2-N) concentrations (microg m(-3)) within air, and the ionic composition of precipitation samples based on sodium (Na+), potassium (K+), magnesium (Mg2+), calcium (Ca2+), chloride (Cl-), sulfate (SO4-S), non-sea salt sulfate (nssSO4-S), ammonium (NH4-N), and nitrate (NO3-N) weighted mean concentrations (mg l(-1)), has been completed. For the air samples, the sulfur dioxide and sulfate concentrations decreased over the sampling period (1980-2004) by 75% and 45%, respectively, whereas no significant trend was observed for nitrogen dioxide. The highest concentrations for sulfur dioxide, sulfate and nitrogen dioxide were associated with wind originating from the easterly and northeasterly directions i.e. those influenced by Irish and European sources. The lowest concentrations were associated with the westerly directions i.e. for air masses originating in the North Atlantic region. This was further verified with the use of backward (back) trajectory analysis, which allowed tracing the movement of air parcels using the European Centre for Medium range Weather Forecasting (ECMWF) ERA-40 re-analysis data. High non-sea salt sulfate levels were being associated with air masses originating from Europe (easterlies) with lower levels from the Atlantic (westerlies). With the precipitation data, analysis of the non-sea salt sulfate concentrations showed a decrease by 47% since the measurements commenced.  相似文献   

4.
The mass concentrations and major chemical components of PM(2.5) in Jinan, Shandong Province, China from Dec. 2004 to Oct. 2008 were analyzed using backward trajectory cluster analysis in conjunction with the potential source contribution function (PSCF) model. The aim of this work was to study the inter-annual variations of mass concentrations and major chemical components of PM(2.5), evaluate the air mass flow patterns and identify the potential local and regional source areas that contributed to secondary sulfate and nitrate in PM(2.5) in Jinan. The annual mean concentrations of PM(2.5), sulfate and nitrate in 2004-2008 were almost the highest in the world. The most significant air parcels contributing to the highest mean concentrations of mass and secondary ions in PM(2.5) originated from the industrialized areas of Shandong Province. Clusters with a lower ratio of NO(3)(-)/SO(4)(2-) in PM(2.5) originated from the Yellow Sea, while a higher ratio was observed in the clusters passing through Beijing and Tianjin. PSCF modeling indicated that the provinces of Shandong, Henan, Jiangsu, Anhui and the Yellow Sea were the major potential source regions for sulfate, in agreement with the cluster analysis results. Regional and long-range transport of NH(4)NO(3) played an important role in the nitrate concentration of Jinan. By comparing the distributions of secondary sulfate and nitrate over three years, enhanced emission control management before and during the 29(th) Olympic Games led to a discernible decrease in source contributions from Beijing and its environs in 2007-2008.  相似文献   

5.
We developed a method to analyze atmospheric SO(x) (particulate SO(4)(2-)+ gaseous SO(2)) and NO(x) (NO + NO(2)) simultaneously using a battery-operated portable filter pack sampler. NO(x) determination using a filter pack method is new. SO(x) and NO(x) were collected on a Na(2)CO(3) filter and PTIO (2-phenyl-4,4,5,5-tetramethylimidazoline-3-oxide-1-oxyl) + TEA (triethanolamine) filters (6 piled sheets), respectively. Aqueous solutions were then used to extract pollutants trapped by the filters and the resulting extracts were pre-cleaned (e.g. elimination of PTIO) and analyzed for sulfate and nitrite by ion chromatography. Recoveries of SO(2) and NO(x) from standard pollutant gases and consistency of the field data with those from other instrumental methods were examined to evaluate our method. SO(x) and NO(x) could be analyzed accurately with determination limits of 0.2 ppbv and 1.0 ppbv (as daily average concentrations), respectively. The sampler can determine SO(x) and NO(x) concentrations at mountainous or remote sites without needing an electric power supply.  相似文献   

6.
为探究典型燃煤工业城市邯郸市的大气细颗粒物(PM2.5)污染水平及水溶性无机离子特征,于2016年1—12月采集了当地大气PM2.5样品,然后利用离子色谱法测得水溶性无机离子的组分,分析了不同季节水溶性无机离子随PM2.5的浓度变化特征。通过对PM2.5中的阴离子、阳离子进行分析发现,SO4^2-、NO3^-和NH4^+在春夏秋冬四季均为PM2.5中的主要离子成分,SO4^2-、NO3^-和NH4^+的浓度之和在春夏秋冬四季占各季节总的水溶性无机离子浓度的百分比分别为84.6%、77.4%、89.9%、62.5%。其中,在春季和冬季含量最高的3种离子分别是NO3^-、SO4^2-和NH4^+,夏季含量最高的3种离子分别是SO4^2-、NH4^+和NO3^-,而秋季含量最高的3种离子分别是NH4^+、SO4^2-和NO3^-。相关性分析发现,2016年春季、夏季和秋季PM2.5为酸性,冬季为碱性。SO4^2-、NO3^-、NH4^+浓度分析表明,冬季PM2.5中的一次建筑扬尘排放较多。通过主成分分析法得出,PM2.5中水溶性无机离子主要来源于二次转化和生物质燃烧。  相似文献   

7.
Total suspended particulate (TSP) samples were collected weekly over a period of one year at four European sites during 1995/6. Two sites were in London-a Central London site (CL, St Paul's Cathedral) and a suburban North London site (NL, Bounds Green); the other two sites were in Porto, Portugal and Vienna, Austria. TSP was collected using a low volume sampler. Organic carbon (OC) and elemental carbon (EC) concentrations were measured using a thermal-optical carbon analyser. Parallel samplers collected TSP for subsequent GC-MS analysis of thirty-nine combustion-associated organic compounds; 16 polyaromatic hydrocarbons (PAHs) and 23 n-alkanes. OC and EC correlate well at all sites (r2 = 0.39-0.65), although the London inter-site correlations were low, suggesting that local sources of OC and EC have a significant influence on local concentrations. Concentrations do not vary widely across the four urban sites, despite the significant differences in urban characteristics. Seasonal patterns of OC:EC ratios were similar at the London and Vienna sites, with highest ratios in autumn and winter, and annual mean OC:EC ratios were identical at these sites. The Carbon Preference Index (CPI) indicated vehicle emissions to have a stronger influence over particulate concentrations at the Vienna and central London sites; there was a stronger biogenic signature in north London and Porto. In addition, two PAH compounds (pyrene and fluoranthene) previously associated with diesel exhaust, were correlated with OC and EC concentrations at the London and Vienna sites.  相似文献   

8.
Various physico-chemical characteristics of the River Yamuna flowing in Haryana through Delhi were studied in the summer (April 1998) and winter (Jan.-Feb. 1999). Ecological parameters like dissolved oxygen (DO), pH, nitrate (NO3-), sulfate (SO4(2-)), and phosphate (PO4(3-)), were analyzed and compared with standard permissible limits to assess the best-designated use of the river water for various purposes. The river in Delhi upstream was of better quality whereas the Delhi downstream stretch was polluted as indicated by very low DO and high total dissolved solids (TDS), electric conductivity (EC), total hardness, Na+, K+, Cl-, F- and SO4(2-). The differences in various parameters were statistically significant (p < 0.01) when compared for the Delhi upstream and downstream stretches of the river, particularly in summer. DO and TDS were found to be two important parameters, which showed strong correlation with several other parameters and hence can serve as good indices of river water quality. The river tended to recover from the pollution stress after flowing through a distance of about 80 km downstream of Delhi.  相似文献   

9.
A highly significant second-order polynomial relation between SO(2) emissions and SO(4)(2-) concentrations during 1970-2000 (r(2)= 0.80, p= <0.001), and a linear relation between NO(x) and NO(3)(-) concentrations during 1991-2000 (r(2)= 0.67, p= 0.004) in bulk precipitation were found for the Hubbard Brook Experimental Forest, NH based on emissions from a 24 h, back-trajectory determined source area. Earlier periods (1965-1980) for SO(2)ratio SO(4)(2-) and longer periods (1965-2000) for NO(x)ratio NO(3)(-) had poorer linear relations, r(2)= 0.03, p= 0.51 and r(2)= 0.22, p= 0.004, respectively. Methodology by the US Environmental Protection Agency for calculating emissions data during this period has changed significantly and frequently, making trend analysis difficult. Given the large potential for errors in estimating emissions and to a lesser extent, deposition, the robust relations between SO(2) emissions and SO(4)(2-) concentrations in bulk precipitation at the Hubbard Brook Experimental Forest show that careful, long-term measurements from a single monitoring site can provide sound and reasonable data on trends in air pollution.  相似文献   

10.
Parametric statistical approaches, correlations and multiple linear regressions were used to develop models for the interpretation of hydrogeochemical parameters in the Western part of Delhi state, India. The hydrogeochemical parameters indicated that the groundwater quality is not safe for consumption. The water is moderately saline and the salinity level is increasing over time. There is also the problem of nitrate pollution. The correlation between electrical conductivity (EC) and other water quality parameters except potassium (K(+)), nitrate (NO(3)(-)) and bicarbonate (HCO(3)(-)) is significantly positive and Ca(++)+ Mg(++)/Na(+)+ K(+) is significantly negative. In predicting EC, the multiple R(2) values of 0.996 and 0.985 indicate that 99.6% and 98.5% variability in the observed EC could be ascribed to the combined effect of Na(+), HCO(3)(-), Cl(-), SO(4)(--), NO(3)(-) and Ca(++)+ Mg(++) for the year of 2005 and 2006 respectively. Out of 99.6% of the variability in EC in 2005, 51.2% was due to Cl(-) alone, and 8.5%, 12.5%, 6.1%, 14.7% and 6.7% were due to Na(+), HCO(3)(-), SO(4)(--), NO(3)(-) and Ca(++) + Mg(++). Similarly in 2006, out of 98.5% of the variability in EC, 48.5% was due to Cl(-) alone, and 10.4%, 12.7%, 5.3%, 17.2% and 4.4% were due to Na(+), HCO(3)(-), SO(4)(--), NO(3)(-) and Ca(++)+ Mg(++). The analysis shows that a good correlation exists between EC, Cl(-) and SO(4)(--) either individually or in combination with other ions and the multiple regression models can predict EC at 5% level of significance.  相似文献   

11.
A field campaign on aerosol chemical properties and trace gases measurements was carried out along the Delhi-Hyderabad-Delhi road corridor (spanning about 3,200 km) in India, during February 1-29, 2004. Aerosol particles were collected on quartz and cellulose filters using high volume (PM(10)) sampler at various locations along the route (i.e., urban, semi-urban, rural, and forest areas) and have been characterized for major cations (Na(+), Ca(2+), Mg(2+), K(+), and NH (4) (+)), anions (Cl(-), NO (3)(-), and SO (4)(2-)), and heavy metals (Cu, Cd, Fe, Zn, Mn, and Pb). Simultaneously, we measured NO(2) and SO(2) gases. These species show large spatial and temporal variations. The ambient PM(10) concentration has been observed to be the highest (55 ± 4 μg m(-3)) near semi-urban areas followed by forest areas (48 ± 2 μg m(-3)) and in rural areas (44 ± 22 μg m(-3)). The concentrations of NO( x ) (NO(2)+NO) and SO(2) ranged from 16 to 69 μg m(-3) and 4 to 11 μg m(-3), respectively. Among anions, NO(3)(-) and SO(4) (2-) are the major constituents of PM(10). The urban and semi-urban sites showed enhanced concentrations of Fe, Zn, Mn, Cd, and Pb. This study provide information about atmospheric concentrations of various species in the northern to central India, which may be important for policy makers to better understand the air quality of the region.  相似文献   

12.
Personal monitoring methods for the determination of hourly integrated concentrations of NO2 and SO2 in ambient air have been developed. Triethanolamine (TEA)-impregnated C18 Sep-Pak cartridges were used to collect NO2 and SO2 simultaneously. After sampling, NO2 and SO2 as their nitrite, nitrate, sulfite and sulfate analogues were stripped from the cartridges with a solution of 5% methanol in distilled, deionized water (DDW) and then determined by ion chromatography. Laboratory tests were conducted to evaluate the sampling rate, collection and recovery efficiencies, breakthrough volumes, absorption capacity, interference and sample stability on the cartridge during storage. NO2 and SO2 detection limits of 0.3 and 0.4 ppb respectively for 1 h samples were obtained. Recoveries for both NO2 and SO2 exceeded 85%.  相似文献   

13.
The compositions, spatial distributions, seasonal variations and ozone formation potential (OFP) of volatile organic compounds (VOCs) were investigated in the atmosphere of Haicang District, Xiamen City, Southeast China. Twenty-four types of VOCs were measured in this study, and ethanol, methylene chloride, toluene, ethyl acetate and isopropyl alcohol were the abundant species based on concentration rank. The concentrations of total VOCs (TVOCs) in industrial areas were higher than those in residential and administrative areas and background site. For industrial areas, the TVOCs concentrations in summer were higher than those in winter, which might result from higher emissions from industrial activities because of stronger evaporation in summer. In contrast, non-industrial areas showed higher concentrations in winter due to the unfavorable meteorological conditions. The spatial distribution of BTEX (benzene, toluene, ethylbenzene and xylene) followed the order of industrial areas > residential and administrative areas > background site, and the concentrations in summer were lower than those in winter for most sites. The high ratios (8.9-14.0) of T/B in this study indicated that industrial emissions were the main sources in this district. X/B ratios were used to assess the ages of air parcels and provided evidence of the transport of air parcels among these sites. Total OFP (TOFP) showed the trend of increase with the increase of TVOCs, and toluene was found as the major contributor to TOFP.  相似文献   

14.
The seasonal variations of concentrations of PAHs in the soil and the air were measured in urban and rural region of Dalian, China in 2007. In soil, mean concentrations of all PAHs in summer were larger than those in winter, whereas the concentrations of heavier weight PAHs in winter were larger than those in summer. Winter/summer concentration ratios for individual PAHs (R(W/S)) increased with the increase of molecular weight of PAHs in soil, indicating that PAHs with high molecular weight were more easily deposited to soil in winter than summer. In air, mean concentrations of all PAHs in winter were larger than those in summer. In comparison with the R(W/S) in soil, all the values of R(W/S) in air were larger than one indicating that the entire individual PAH concentrations in winter were larger than those in summer. The average concentration composition for each PAH compound in soil and air samples was determined and the seasonal change of PAH profile was very small. It was suggested that PAHs in soils and air had the same or similar sources both in winter and summer. The approach to the soil-air equilibrium was assessed by calculating fugacity quotients between soil and air using the soil and air concentrations. The calculated soil-air fugacity quotients indicated that soil acted as a secondary source to the atmosphere for all lighter weight PAHs (two-three rings) and it will continue to be a sink for heavier weight PAHs (five-six rings) in the Dalian environment, both in winter and summer. Medium weight PAHs (four-five rings) were close to the soil-air equilibrium and the tendency shifted between soil and air when season or function region changed. The fugacity quotients of PAHs in summer (mean temperature 298 K) were larger than those in winter (mean temperature 273 K), indicating a higher tendency in summer than winter for PAHs to move from soil to air. The variation of ambient conditions such as temperature, rainfall, etc. can influence the movement of PAHs between soil and air. Most of the fugacity quotients of PAHs for the urban sites were larger than that for the rural site both in winter and summer. This phenomenon may be related with that the temperatures in urban sites were higher than those in the rural site because of the urban heat island effect.  相似文献   

15.
A temporary renovation activity releases considerably high concentrations of particulate matter, viable and non-viable, into air. These pollutants are a potential contributor to unacceptable indoor air quality (IAQ). Particulate matter and its constituents lead, sulfate, nitrate, chloride, ammonium and fungi as well as fungal spores in air were evaluated in a building during renovation action. Suspended dust was recorded at a mean value of 6.1 mg m(-3) which exceeded the Egyptian limit values for indoor air (0.15 mg m(-3)) and occupational environments (5 mg m(-3)). The highest particle frequency (23%) of aerodynamic diameter (dae) was 1.7 microm. Particulate sulfate (SO(4)(2-)), nitrate (NO(3)(-)), chloride (Cl(-)), ammonium (NH(4)(+)) and lead components of suspended dust averaged 2960, 28, 1350, 100 and 13.3 microg m(-3), respectively. Viable fungi associated with suspended dust and that in air averaged 1.11 x 10(6) colony forming unit per gram (cfu g(-1)) and 92 colony forming unit per plate per hour (cfu p(-1) h(-1)), respectively. Cladosporium(33%), Aspergillus(25.6%), Alternaria(11.2%) and Penicillium(6.6%) were the most frequent fungal genera in air, whereas Aspergillus(56.8%), Penicillium(10.3%) and Eurotium(10.3%) were the most common fungal genera associated with suspended dust. The detection of Aureobasidium, Epicoccum, Exophiala, Paecilomyces, Scopulariopsis, Ulocladium and Trichoderma is an indication of moisture-damaged building materials. Alternaria, Aureobasidium, Cladosporium, Scopulariopsis and Nigrospora have dae > 5 microm whereas Aspergillus, Penicillium and Verticillium have dae < 5 microm which are suited to penetrate deeply into lungs. Particulate matter from the working area infiltrates the occupied zones if precautionary measures are inadequate. This may cause deterioration of IAQ, discomfort and acute health problems. Renovation should be carefully designed and managed, in order to minimize degradation of the indoor and outdoor air quality.  相似文献   

16.
The Po valley in northern Italy is renowned for its high air pollutant concentrations. Measurements of air pollutants from a background site in Modena, a town of 200 thousand inhabitants within the Po valley, are analysed. These comprise hourly data for CO, NO, NO(2), NO(x), and O(3), and daily gravimetric equivalent data for PM(10) from 1998-2010. The data are analysed in terms of long-term trends, annual, weekly and diurnal cycles, and auto-correlation and cross-correlation functions. CO, NO and NO(2) exhibit a strongly traffic-related pattern, with daily peaks at morning and evening rush hour and lower concentrations over the weekend. Ozone shows an annual cycle with a peak in July due to local production; notwithstanding the diurnal cycle dominated by titration by nitrogen oxide, the decreasing long term trend in NO concentration did not affect the long term trend in O(3), whose mean concentration remained steady over the sampling period. PM(10) shows a strong seasonality with higher concentration in winter and lower concentration in summer and spring. Both PM(10) and ozone show a marked weekly cycle in summer and winter respectively. Regressions of PM(10) upon NO(x) show a consistently greater intercept in winter, representing higher secondary PM(10) in the cooler months of the year. There is a seasonal pattern in primary PM(10) to NO(x) ratios, with lower values in winter and higher values in summer, but the reasons are unclear.  相似文献   

17.
Water quality throughout south Florida has been a major concern for many years. Nutrient enrichment in the Indian River Lagoon (IRL) is a major surface water issue and is suggested as a possible cause of symptoms of ecological degradation. In 2005-06, water samples were collected weekly from seven sites along Ten Mile Creek (TMC), which drains into the Indian River Lagoon, to investigate and analyze spatial and temporal fluctuations of nutrients nitrogen (N) and phosphorus (P). The objective of this study was to understand the relationships among chlorophyll a concentration, nutrient enrichment and hydrological parameters in the surface water body.High median concentrations of total P (TP, 0.272 mg L(-1)), PO4-P (0.122 mg L(-1)), and dissolved total P (DTP, 0.179 mg L(-1)); and total N (TN, 0.988 mg L(-1)), NO3(-)-N (0.104 mg L(-1)), NH4+-N (0.103 mg L(-1)), and total Kjeldahl N (TKN, 0.829 mg L(-1)), were measured in TMC. The concentrations of TP, PO4-P, DTP, TN, NO3(-)-N, NH4+-N, and TKN were higher in summer and fall than in winter and spring. However, chlorophyll a and pheophytin concentrations during this period in TMC varied in the range of 0.000-60.7 and 0.000-17.4 microg L(-1), with their median values of 3.54 and 3.02 microg L(-1), respectively. The greatest mean chlorophyll a (10.3 microg L(-1)) and pheophytin (5.71 microg L(-1)) concentrations occurred in spring, while the lowest chlorophyll a (1.49 microg L(-1)) and pheophytin (1.97 mug L(-1)) in fall. High concentrations of PO4-P (>0.16 mg L(-1)), DTP (>0.24 mg L(-1)), NO3(-)-N (>0.15 mg L(-1)), NH4+-N (>0.12 mg L(-1)), and TKN (>0.96 mg L(-1)), occurred in the upstream of TMC, while high concentrations of chlorophyll a (>6.8 mug L(-l)) and pheophytin (>3.9 microg L(-l)) were detected in the downstream of TMC. The highest chlorophyll a (11.8 mug L(-l)) and pheophytin (6.06 microg L(-l)) concentrations, however, were associated with static and open water conditions. Hydrological parameters (total dissolved solid, electrical conductivity, salinity, pH, and water temperature) were positively correlated with chlorophyll a and pheophytin concentrations (P < 0.01) and these factors overshadowed the relationships between N and P concentrations and chlorophyll a under field conditions. Principal component analysis and the ratios of DIN/DP and TN/TP in the water suggest that N is the limiting nutrient factor for phytoplankton growth in the TMC and elevated N relative to P is beneficial to the growth of phytoplankton, which is supported by laboratory culture experiments under controlled conditions.  相似文献   

18.
The emission of nitrogen compounds from power plants accounts for a significant proportion of the total emissions of nitrogen to the atmosphere. This study seeks to understand the nature of chemical reactions in the atmosphere involving nitrogen, which is important in undertaking quantitative assessments of the contribution of such reactions to local and regional air pollution. The slant column density (SCD) of power-plant-generated NO(2) was derived using imaging differential optical absorption spectroscopy (I-DOAS) with scattered sunlight as a light source. The vertical structure of NO(2) SCD from power plant stacks was simultaneously probed using a pushbroom sensor. Measured SCDs were converted to mixing ratios in calculating the rate of NO(2) increase at the center of the plume. This study presents quantitative measurements of the rate of NO(2) increase in a rising plume. An understanding of the rate of NO(2) increase is important because SO(2) and NO(x) compete for the same oxidizing radicals, and the amount of NO(x) is related to the rates of SO(2) oxidation and sulfate formation. This study is the first to directly obtain the rate of NO(2) increase in power plant plumes using the I-DOAS technique. NO(2) increase rates of 60 and 70 ppb s(-1) were observed at distances of about 45 m from the two stacks of the Pyeongtaek Power Plant, northwest South Korea.  相似文献   

19.
Water-soluble inorganic ions in aerosol samples have been studied. The sample collection took place during summer in 2003 at a European background site which is operating within the framework of the European Monitoring and Evaluation Program. Gent type PM10 stacked filter unit (SFU) samplers were operated in parallel on a day and night basis to collect particles in separate coarse (2.0-10 microm) and fine (<2.0 microm) size fractions. Particulate masses were measured gravimetrically; the filters from one of the SFU samplers were analyzed by particle-induced X-ray emission spectrometry (PIXE) and instrumental neutron activation analysis (INAA). Filters from the other SFU sampler were analyzed by ion chromatography (IC) for major inorganic anions (MSA-, NO2(-), NO3(-), Cl-, Br-, SO4(2-), oxalate) and cations (Na+, K+, NH4(+), Mg2+, Ca2+). The water-soluble inorganic ions measured were responsible for 44% and 16% of the total fine and coarse particulate mass, respectively. In the fine size fraction, the main ionic components were SO4(2-) and NH4(+) accounting for about 90% of fine ionic mass. In the coarse fraction the main ionic components were Ca2+ and NO3(-), followed by SO4(2-). Significant day and night difference in the mass concentrations was observed only for fine NO3(-). The molar ratios of fine NH4(+) to SO4(2-) indicated their complete neutralization to (NH4)2SO4. According to the cation-to-anion ratios the coarse particles were alkaline, while the fine particles were slightly acidic or neutral. By comparing the corresponding concentrations obtained from PIXE/INAA and IC, we determined the water-extractable part of the individual species. We also investigated the effect of long-range transported air masses on the local air concentrations, and we found that the air quality of this background monitoring station was affected by regional pollution sources.  相似文献   

20.
The objective of this work was to develop a novel wet-scrubbing process using Fe(VI) for the simultaneous removal of gaseous NO and SO(2). The oxidation of SO(2) and NO with Fe(VI) was studied in aqueous solution at alkaline pH (9.0-11.0). A stoichiometric molar ratio for NO and SO(2) oxidation with Fe(VI) was determined to be nearly 3.0. Sulfate and nitrate was identified as final products by ion chromatography from the reaction at pH 9.0-11.0. The feasibility of simultaneous removal of multiple gas pollutants with the continuous feeding of ferrate in lab-scale was investigated from the view of industrial application. It was found that the removal efficiency of NO and SO(2) was enhanced with the increase of Fe(VI) concentration, more than 90% NO removal efficiency and 100% SO(2) removal efficiency were achieved by wet-scrubbing process using Fe(VI) at room temperature and ambient atmosphere. The results demonstrate that Fe(VI) could be an effective wet-scrubbing agent for the simultaneous removal of NO and SO(2).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号