首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 737 毫秒
1.
The purpose of this study was to compare tanker drivers' occupational exposure level before and after the installation of vapour recovery facilities at 14 service stations. Road tanker drivers are exposed when handling volatile petrol liquid in bulk in the distribution chain. The drivers' exposure was studied during the unloading operation as the bulk petrol flowed into underground storage tanks, displacing vapours in the tank space and causing emission to the environment and the drivers' work area. The exposures were measured again when the dual point Stage I vapour recovery systems were installed for recycling vapours. Short-term measurements were carried out in the drivers' breathing zones by drawing polluted air through a charcoal tube during unloading. The samples were analysed in the laboratory by gas chromatography for C3-C11 aliphatic hydrocarbons, tert-butyl methyl ether (MTBE), tert-amyl methyl ether (MTAE), benzene, toluene and xylene. The road tanker loads delivered consisted of oxygenated and reformulated petrol (E95 and E98 brands), which contained on average 13% oxygenates. Before the installation of the vapour recovery system, the geometric mean (GM) concentration of aliphatic hydrocarbons was 65 mg m-3 (range 6-645 mg m-3) in the drivers' breathing zones. After the installation at the same service stations, the corresponding exposure level was 8.3 mg m-3 (range < 1-79 mg m-3). The GM of the MTBE concentrations was 8.6 mg m-3 (range 1-67 mg m-3) without vapour recovery and 1.5 mg m-3 (range < 0.1-10 mg m-3) with vapour recovery. The differences between the aliphatic hydrocarbons and the MTBE exposure levels during the unloading of the road tankers without and with vapour recovery were statistically significant (p < 0.05).  相似文献   

2.
Diffusive sampling of methyl isocyanate (MIC) on 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ)-coated glass fibre (GF) filters is strongly affected by high relative humidity (RH) conditions. It is shown that the humidity interference is a physical phenomenon, based on displacement of reagent from the filter surface. In this paper, this drawback has been overcome by changing the filter material to the less polar polystyrene divinyl benzene (SDB). A series of experiments was performed to compare the analyte uptake on the two filter materials for different sampling periods and analyte concentrations at both low and high RH conditions. Additionally, the materials were investigated as well for passive sampling of ethyl (EIC) and phenyl isocyanate (PhIC) with NBDPZ and 1-(2-methoxyphenyl) piperazine (2-MP) as an alternative derivatising agent. Using 2-MP, the mean GF/SDB response ratios were determined to be 1.02 for MIC (RSD: 6.1%) and 1.03 for EIC (RSD: 6.8%), whereas PhIC could only be determined on SDB filters. Using NBDPZ as reagent, the negative influence of high humidity disappeared when SDB filters were used instead of GF filters. Even at low RH conditions, sampling with SDB material generally resulted in a higher analyte uptake than with GF filters. The GF/SDB response ratios were independent of sampling time or analyte concentration and were determined to be 0.70 (RSD: 4.7%) for MIC, 0.84 (RSD: 4.5%) for EIC and 0.95 (RSD 5.4%) for PhIC, meaning that the NBDPZ diffusive sampler based on SDB can be used at all humidity conditions without any restrictions.  相似文献   

3.
The evaluation of a novel prototype instrument designed for on-site determinations of VOC mixtures found in indoor working environments is described. The instrument contains a miniature multi-stage preconcentrator, a dual-column separation module with pressure-tunable retention capabilities, and an integrated array of three polymer-coated surface acoustic wave sensors. It was challenged with dynamic test-atmospheres of a set of 15 common indoor air contaminants at parts-per-billion concentrations within a stainless-steel chamber under a range of conditions. Vapours were reliably identified at a known level of confidence by combining column retention times with sensor-array response patterns and applying a multivariate statistical test of pattern fidelity for the chromatographically resolved vapours. Estimates of vapour concentrations fell within 7% on average of those determined by EPA Method TO-17, and limits of detection ranged from 0.2 to 28 ppb at 25 degrees C for 1 L samples collected and analyzed in <12 min. No significant humidity effects were observed (0-90% RH). Increasing the chamber temperature from 25 to 30 degrees C reduced the retention times of the more volatile analytes which, in turn, demanded alterations in the scheduling of column-junction-point pressure (flow) modulations performed during the analysis. Reductions in sensor sensitivities with increasing temperature were predictable and similar among the sensors in the array such that most response patterns were not altered significantly. Short-term fluctuations in concentration were accurately tracked by the instrument. Results indicate that this type of instrument could provide routine, semi-autonomous, near-real-time, multi-vapour monitoring in support of efforts to assess air quality in office environments.  相似文献   

4.
A diffusive sampling method for the determination of methyl isocyanate (MIC) in air is introduced. MIC is collected using a glass fiber filter impregnated with 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ). The urea derivative formed is desorbed from the filter with acetonitrile and analyzed by means of high-performance liquid chromatography (HPLC) using fluorescence detection (FLD) with lambdaex = 471 nm and lambdaex = 540 nm. Additionally, a method was developed using tandem mass spectrometric (MS-MS) detection, which was performed as selected reaction monitoring (SRM) on the transition [MIC-NBDPZ + H]+ (m/z 307) to [NBDPZ + H]+ (m/z 250). The diffusive sampler was tested with MIC concentrations between 1 and 35 microg m(-3). The sampling periods varied from 15 min to 8 h, and the relative humidity (RH) was set from 20% up to 80%. The sampling rate for all 15 min experiments was determined to be 15.0 mL min(-1) (using HPLC-FLD) with a relative standard deviation of 9.9% for 56 experiments. At 80% RH, only 15 min sampling gave acceptable results. Further experiments revealed that humidity did not affect the MIC derivative but the reagent on the filter prior to and during sampling. The sampling rate for all experiments (including long term sampling) performed at 20% RH was found to be 15.0 mL min(-1) with a relative standard deviation of 6.3% (N = 42). The limit of quantification was 3 microg m(-3) (LC-MS-MS: 1.3 microg m(-3)) for 15 min sampling periods and 0.2 microg m(-3) (LC-MS-MS: 0.15 microg m(-3)) for 8 h sampling runs applying fluorescence detection.  相似文献   

5.
Mercury vapour adsorption tubes manufactured for pumped sampling and analysis have been evaluated for their performance as passive samplers. This has been done by exposing these tubes in a novel micro-exposure chamber. The uptake rates of these tubes have been found to be low (approximately 0.215 ml min(-1)) as compared to bespoke passive samplers for mercury vapour (typically in excess of 50 ml min(-1)). The measured uptake rates were shown to vary significantly between tubes and this was attributed to the variability in the air-sorbent interface and the proportion of the cross sectional area removed by the crimp in the quartz tubes used to secure the sorbent material. As a result of this variability the uptake rate of each tube must be determined using the micro-exposure chamber prior to deployment. Results have shown that the uptake rate determined in the micro-exposure chamber is invariant of concentration, and therefore these uptakes rates may be determined at a high mercury vapour concentration for many tubes at once in less than one hour. The uptake rate of the adsorption tubes under these conditions may be determined with a precision of 5%. Measurements made on a limited field trial in indoor and outdoor ambient air have shown that these tubes give results in acceptable agreement with more traditional pumped sampling methods, although longer sampling periods are required in order to reduce the uncertainty of the measurement, which is currently approximately 30%.  相似文献   

6.
A system, based on annular gold-coated denuders, was optimized and used in the atmospheric sampling of mercury in urban and rural sites of the Alta Floresta, a region in the Brazilian Amazon. Results showed that vapour phase mercury (Hgv) is dominant in samples collected in both sites. However, particulate mercury (Hg) may sometimes be significant at the urban site, with values representing up to 77% of the total Hg collected during sampling, but may also be insignificant at the same site, depending on the gold commercialization activity and, probably, on the meteorological conditions during the sampling period. The presence of mercury in both the vapour and particulate phases in the atmosphere of the urban site can explain the high mercury concentrations found in urban dust reported for some cities in the Amazon, and also the relatively high Hg concentrations found in soils adjacent to the urban centre of Alta Floresta. It appears that the urban dust of "garimpo" areas in the Amazon can act as an efficient adsorber of Hgv emitted by gold dealer operations during the purification process. Mercury emissions from gold dealer shops in the Amazon have been considered as a human health risk through the inhalation of Hg vapour. However, although true for indoor sites, the significant contribution of particulate phase Hg shown in this study in outdoor urban sites calls for a re-evaluation of the risk assessment estimates performed up to now in urban centres in the Amazon.  相似文献   

7.
Exposure to perchlorethylene, especially for dry cleaning workers and for people living near dry cleaning shops, could lead to several diseases and disorders. This study examines the value of solid-phase microextraction (SPME) for sampling perchlorethylene in the atmosphere of dry cleaning shops. Carboxen/polydimethylsiloxane (CAR/PDMS) in 0.5-cm retracted mode was selected. There were no significant differences between sampling rates at different temperatures (range of 20 to 30 °C) and air velocities (2 to 50 cm/s). On the opposite, relative humidity (RH) had a significant effect on sampling rates. Method reproducibility was realized in the laboratory and field conditions and was 6.2 % and 7 to 11 %, respectively. Repeatability was also determined as 8.9 %. Comparison of the results according to the American Industrial Hygiene Association exposure assessment strategy showed the SPME sampler yields more conservative results in comparison with traditional standard method.  相似文献   

8.
Exposure to vapours of volatile chemicals is a major occupational and environmental health concern. Toxicity testing of volatile organic compounds (VOCs) has always faced significant technological problems due to their high volatility and/or low solubility. The aim of this study was to develop a practical and reproducible in vitro exposure technique for toxicity testing of VOCs. Standard test atmospheres of xylene and toluene were generated in glass chambers using a static method. Human cells including: A549-lung derived cell lines, HepG2-liver derived cell lines and skin fibroblasts, were grown in porous membranes and exposed to various airborne concentrations of selected VOCs directly at the air/liquid interface for 1 h at 37 degrees C. Cytotoxicity of test chemicals was investigated using the MTS (3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium) and NRU (neutral red uptake) assays following 24 h incubation. Airborne IC(50) (50% inhibitory concentration) values were determined using dose response curves for xylene (IC(50)=5350+/- 328 ppm, NRU; IC(50)=5750+/- 433 ppm, MTS in skin fibroblast) and toluene (IC(50)=0 500+/- 527 ppm, NRU; IC(50)=11,200 +/- 1,044 ppm, MTS in skin fibroblast). Our findings suggest that static direct exposure at the air/liquid interface is a practical and reproducible technique for toxicity testing of VOCs. Further, this technique can be used for inhalational and dermal toxicity studies of volatile chemicals in vitro as the exposure pattern in vivo is closely simulated by this method.  相似文献   

9.
The solvent-free sampler for airborne isocyanates consisted of a polypropylene tube with an inner wall coated with a glass fibre filter, coupled in series with a 13 mm glass fibre filter. The filters were impregnated with reagent solution containing equimolar amounts of di-n-butylamine (DBA) and acetic acid. Air sampling was performed with an air flow of 0.2 l min(-1). The formed isocyanate-DBA derivatives were determined using liquid chromatography and tandem mass spectrometry. The sampler was investigated in regard to collection principle and extraction of the formed derivatives with good results. The possibility to store the sampler before sampling and to perform long-term sampling was demonstrated. Field extraction of the sampler was not necessary, as there was no difference between immediately extracted samples and stored ones (2 days). In comparative studies, the sampler was evaluated against a reference method, impinger-filter sampling with DBA as reagent. The ratios between the results obtained with the sampler and the reference in a test chamber at a relative humidity (RH) of 45% was in the range of 83-109% for isocyanates formed during thermal decomposition of PUR. At RH 95%, the range was 72-101% with the exception of isocyanic acid. In two field evaluations, the ratios for fast curing 2,4'- and 4,4'-methylene bisphenyl diisocyanate (MDI) was in the range 81-113% and for the 3-ring MDI the range was 54-70%. For the slower curing 1,6-hexamethylene diisocyanate (HDI) and HDI isocyanurate, the ratios were in the range 78-145%. In conclusion, the solvent-free sampler is a convenient alternative in most applications to the more cumbersome impinger-filter sampler.  相似文献   

10.
对石家庄市2016年12月14—23日一次重污染过程的逐时空气质量和气象资料进行了分析。结果表明,低压均压类天气控制下,较高的相对湿度和水汽压,<2.5 m/s的低风速以及<500 m的混合层高度是该次重污染形成和持续的重要原因。当风速<2.5 m/s,且相对湿度>45%或水汽压>3.6 hPa时,空气质量明显较差;当风速<2 m/s,且湿度>65%或水汽压>4 hPa时,污染级别达到严重污染;该次重污染形成与维持的地面气压临界值为1 017 hPa,当气压>1 017 hPa时,环境空气质量相对较好;当气压<1017 hPa时,更容易发生严重污染。  相似文献   

11.
The Golden Horn Estuary located in the Istanbul region of Turkey has been thought to be a heavily polluted area since the 1950s: the concentration of the elements, which include heavy metals such as Cu2+, Mn2+, Ni2+, Zn2+, Pb2+, Cd2+, and Fe2+, was therefore investigated in sediment and water samples of the area. The resistance of Enterobacteriaceae members to some heavy metal salts was investigated to determine levels of metal-resistant bacteria in the Golden Horn Estuary after the environmental restoration project in 1998. The sediment samples were collected with an Ekman-Grab in the period from November 2002 to February 2004 from depths of 4-15 m and analyzed by means of an atomic absorption spectrophotometer. Analyses of average heavy metals of sediment samples yielded the following results: 131.5 ppm Cu, 405.5 ppm Mn, 46.5 ppm Ni, 191.2 ppm Zn, 81.5 ppm Pb and 27668 ppm Fe. As with water, Ni concentrations in sediment were found lower than that in limit values. Frequency of heavy metals resistance to Cu, Zn, Fe, Ni, Mn, Pb and Cd was detected as an average of 65.0%, 64.4%, 62.5%, 38.4%, 37.3%, 36.2% and 28.4%, respectively in a total of 192 strains isolated from sediment samples. It was observed that there was no statistically significant difference among the results of analyses with respect to sampling dates. Despite the environmental restoration project in 1998, our study results showed that heavy metal levels were still high in the sediment and this situation induced the tolerance of bacteria to some heavy metals.  相似文献   

12.
By using a dynamic dilution system, the atmospheric measurement of 11 selected toxics VOCs (ethylene, acetylene, propene, 1-butene, 1,3-butadiene, 1-pentene, 1-hexene, benzene, toluene, ethylbenzene, m+p-xylene) from the list WHO of 1996 and TO-14 method of US EPA by preconcentration by thermal desorption (TD), analysis by gas chromatography (GC), identification and quantification with a flame ionisation detector (FID) was developed and validated in term of metrology, especially the techniques of sampling of these VOCs with adsorbents cartridges "Air Toxics" when used with an "UMEG sampler" equipped in the inlet with a nafion membrane. In particular the influence of climatic conditions (temperature and relative humidity) and the influence of chemical factors like ozone, on the representativity of sampling were studied. Experiments made with various humidities showed that the addition of a nafion membrane in the inlet of the sampling system was required. Without this membrane, losses of compounds were observed for RH >50%. With this membrane, storage for 2 weeks in a refrigerator, as for canisters, did not induce a loss of compounds. No significative decrease of concentrations of the studied VOCs after 14 days storage, which are known to react with ozone, were observed with an ozone concentrations of 55 ppb. One explanation is that nafion membrane, placed in the inlet of the sampler, will neutralize ozone before entering the sampling tubes. This observation is in accordance with literature which states that the sampling of VOCs on Carbotrap cartridges without ozone scrubber induce a loss of compounds.  相似文献   

13.
An automatic monitor has been developed for measuring formaldehyde in air using a sensitive tape for formaldehyde. It is based on the color change of the tape on reaction with formaldehyde. The porous cellulose tape, containing silica gel as an absorbent and impregnated with the processing solution containing hydroxylamine sulfate, Methyl Yellow (pH indicator; pH 2.9-4.0, red-yellow), glycerin and methanol, was found to be a highly sensitive means of detecting formaldehyde and maintains a stable sensitivity. When the tape was exposed to a sample of air containing formaldehyde, the color of the tape changed from yellow to red. The degree of color change was proportional to the concentration of formaldehyde at a constant sampling time and flow rate, and it could be recorded by measuring the intensity of reflected light (555 nm). The tape could be used to detect down to 0.08 ppm (World Health Organization standard) of formaldehyde with a sampling time of 30 min and a flow rate of 100 mL min-1. Reproducibility tests showed that the relative standard deviation of response (n = 10) was 3.8% for 0.1 ppm formaldehyde. The monitor is simple, specific, capable of unattended operation and is recommended for both laboratory and field operation.  相似文献   

14.
Fused-silica-lined (FSL) canisters and SUMMA polished (SUMMA) canisters were compared for the recoveries and the stabilities of 58 volatile organic compounds (VOCs) at low ppbv (volume/volume) levels under various humidified conditions using a three-stage preconcentration method followed by GC-MS analysis. The target VOCs included non-polar VOCs (e.g. halogenated hydrocarbons and aromatic hydrocarbons) and polar VOCs (e.g. alcohols, ketones, esters, ethers, nitriles and thiols). The three-stage preconcentration method was initially optimized for simultaneous analysis of non-polar and polar VOCs because determination of canister stability is dependent on the accuracy of analytical measurements. The method showed good linearity over the concentration range from 1 to 25 ppbv for all target analytes, and the correlation coefficients were higher than 0.9974. The method detection limits ranged from 0.023 to 0.39 ppbv. The test mixtures loaded in both type of canisters (n = 3) had concentrations of 1.7-2.5 ppbv per compound at ambient pressure under various humidified conditions (%RH = 1.6, 8.0, 27, 39, 53 and >99% with excess water present). All canister samples were initially analyzed on day 0 (after 6-12 h). The effect of competitive adsorption of water vapor and polar VOCs on active sites of interior surface was remarkably observed for SUMMA canisters. Polar VOCs had a greater requirement for water vapor to be present. The RH percentages that ensured good recovery on day 0 were RH > 8% for non-polar VOCs and RH > 27% for polar VOCs (except alcohols under the condition of RH > 99%). All thiols were not recovered from SUMMA canisters under all conditions. FSL canisters showed good recoveries of more than 86% for all VOCs under all conditions on day 0 (except alcohols under the condition of RH > 99%). The recoveries of alcohols in both canisters under the condition of RH > 99% displayed relatively low recoveries in the range 25-76% because of the partitioning effect into condensed water. The canister samples under the conditions of RH 8.0, 27, 53 and > 99% were analyzed for the stability test on days 3, 7, 14 and 28 after loading. All non-polar VOCs were reasonably stable in the FSL canisters under all examined conditions over 28 days. However, several polar VOCs that have relatively lower vapor pressure, e.g. MIBK, butyl acetate and alcohols except ethanol, showed unstable characteristics under relatively dry conditions (RH 8 and 27%) during 28 days. RH > 53% was needed to ensure good stabilities of all analytes except thiols with the recoveries of > 80% over 28 days for both canisters. Although the FSL canister showed good recoveries of more than 86% for thiols on day 0, drastic degradations were observed after day 3 and they were not detected after day 14.  相似文献   

15.
Monitoring of the workplace concentration of 3-methoxybutyl acetate (MBA), which is used in printer's ink and thinner for screen-printing and as an organic solvent to dissolve various resins, is important for health reasons. An active and a diffusive sampling method, using a gas chromatograph equipped with a flame ionization detector, were developed for the determination of MBA in workplace air. For the active sampling method using an activated charcoal tube, the overall desorption efficiency was 101%, the overall recovery was 104%, and the recovery after 8 days of storage in a refrigerator was more than 90%. For the diffusive sampling method using the 3M 3500 organic vapor monitor, the MBA sampling rate was 19.89 cm(3) min(-1). The linear range was from 0.01 to 96.00 microg ml(-1), with a correlation coefficient of 0.999, and the detection limits of the active and diffusive samplers were 0.04 and 0.07 microg sample(-1), respectively. The geometric mean of stationary sampling and personal sampling in a screen-printing factory were 12.61 and 16.52 ppm, respectively, indicating that both methods can be used to measure MBA in workplace air.  相似文献   

16.
The use of chloride as a tracer for soil water investigations is discussed. Limitations with laboratory based soil core and field based sampling are considered with respect to the poor suitability of the data for rigorous assessment of mechanistic models. Investigation of water movement in soil has been restricted by limitations in spatial and temporal sampling. Fine resolution sampling generates large numbers of samples which cause problems with post sampling laboratory analysis. This paper describes a field-based system for the analysis of chloride in soil water. There are three component parts to the system, (i) a custom sampling sub-system comprising of ceramic cup suction samplers and sample traps, (ii) a sample routing sub-system to channel sample to (iii) a sample analysis sub-system utilizing a flow injection method for sample analysis using a custom built photo-diode detector. The three sub-systems were controlled by a suitably equipped personal computer. A calibration procedure is described with a third order polynomial equation derived to convert millivolt response from the detector into chloride concentration. Field and laboratory data from a tracer experiment are presented and discussed, and it is concluded that the system is well suited to field-based applications. Finally it is noted that the photo-detector is suitable for colourimetric analysis of any tracer with suitable chemical determination.  相似文献   

17.
A majority of households in developing countries rely on biomass fuel for cooking, typically burned in open fires or simple stoves. The incomplete combustion of these fuels causes adverse health effects such as respiratory diseases, especially among women and children. However, quantitative data on pollution levels and on associated diseases are limited. We examined cooking habits and self-reported health in 31 households with outdoor open wood fires in Ouagadougou, Burkina Faso, using structured interviews. In eight households, carbon monoxide (CO) was measured using passive sampling. In addition, meteorology and ambient CO concentrations were assessed. The average CO concentration during cooking was 4.3 ppm, with a maximum of 65.3 ppm and minimum of 0.3 ppm (1-min values). A clear daily pattern was observed, with relatively low concentrations during the day and high during the evening, occasionally exceeding the World Health Organization 1- and 8-h guidelines when the air stabilised. On average, CO concentrations were 43 % higher in kitchens located in closed yards than in those located in open yards, showing that fireplace location affected the levels. Eye irritation and coughing among women and children were reported by 30 % of the households. Based on previously reported relations between CO concentrations and fine particles (<2.5 μm), the exposure to biomass smoke appears to be high enough to pose a considerable health risk among women and children in households with outdoor open wood fires. The results suggest that burning should be limited between sunset and dawn and in areas with limited ventilation to reduce pollutions levels.  相似文献   

18.
Methods to monitor contamination of workplaces with antineoplastic drugs have been developed and validated. Cyclophosphamide (CP) was used as a model compound as it is one of the most commonly used antineoplastic drugs. A wipe sampling method to detect contamination with CP at surfaces was developed. A personal air sampling method to sample gas and vapour on solid sorbent tubes and particles with filters was also developed. Wipe and filter samples were extracted and sorbent samples were eluted, all with ethyl acetate. The samples were analysed with liquid chromatography tandem mass spectrometry. (2)H(6)-labelled cyclophosphamide was used as an internal standard. The between-day precision was 2-5% for wipe samples, 4-6% for sorbent samples and 3-8% for filter samples. The limit of detection was 0.02 ng CP per sample for the wipe and filter methods and 0.03 ng CP per sample for the solid sorbent method. Wipe sampling on surfaces made of different materials resulted in mean recoveries between 78-106%. The desorption recovery was between 97-102% for the wipe samples, 97% for the sorbent samples and 101% for the filter samples. Samples were stable for up to 2 months at 5 degrees C and -20 degrees C and for about 2 d at room temperature. The developed methods were applied to the measurement of contamination with CP in a hospital pharmacy. Trace amounts of CP, 1.3 and 1.4 ng, were detected on surfaces in the pharmacy.  相似文献   

19.
The application of a phosphorus monitoring device based on microsystems technology (MST) to the analysis of river water is presented. An alternative to the standard molybdenum blue method known as the yellow vanadomolybdophosphoric acid method has been very effectively implemented. The method is simple, a reagent and sample are mixed in a 1:1 ratio forming a yellow complex that absorbs strongly below 400 nm in the UV spectrum. The kinetics of the reaction are rapid and sample turnaround is typically 3 min at room temperature. Therefore a very uncomplicated microfluidic design can be adopted. The working wavelength was chosen as 380 nm to coincide with the peak output of a UV-LED narrow bandwidth light source recently developed by Nichia. The limit of detection for the yellow method in the microfluidic system is 0.2 ppm with a dynamic linear range from 0-50 ppm. The method was applied to a measurement of phosphorus in a local river at specific sampling points along its course.  相似文献   

20.
In order to encourage more exposure measurements to be performed, a formic acid gas-phase biosensor has been developed for this purpose. In the present paper, an enzyme based biosensor has been validated with respect to analyte selectivity and on-site use. To ensure that the sampler developed measures the compound of interest the biosensor was exposed to three near structural homologues to formic acid, i.e. acetic acid, methanol and formaldehyde. These vapours were generated with and without formic acid and the only compound that was found to have an effect on the performance of the biosensor, albeit a small one, was acetic acid. The field test was performed in a factory using formic acid-containing glue for glulam products. In parallel to the measurements with the biosensor a well defined reference method was used for sampling and analysing formic acid. It was found that the biosensor worked satisfactorily in this environment when used in a stationary position. It was also shown that the biosensor could determine formic acid vapour concentrations down to 0.03 mg m(-3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号