首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
4-[N,N-(Diethyl)amino] benzaldehyde thiosemicarbazone (DEABT) is proposed as an analytical reagent for the spectrophotometric determination of platinum(IV). The DEABT forms 1:2 yellow complex with Pt(IV), which is sparingly soluble in water and completely soluble in water–ethanol–DMF medium. The Pt(IV)–DEABT complex shows maximum absorbance at 405 nm. Beer’s law is valid up to 7.80 μg cm???3, and optimum concentration range for the determination of platinum(IV) is 0.48–7.02 μg cm???3. The molar absorptivity and Sandell’s sensitivity of the method are found to be 1.755 × 104 dm3 mol???1 cm???1 and 0.0012 μg cm???2, respectively. The relative error and coefficient of variation (n?=?6) for the method does not exceed ±0.43% and 0.35%, respectively. Since the method tolerates a number of metal ions commonly associated with platinum, it can be employed for the determination of platinum in environmental samples, pharmaceutical samples, alloys, catalysts, and complexes. The method is rapid as the Pt(IV)–DEABT complex is soluble in water–ethanol–DMF medium and not requiring any time consuming extraction method for the complex.  相似文献   

2.
A new spectrophotometric method is reported for the determination of nanomolar level of malachite green in surface water samples. The method is based on the catalytic effect of silver nanoparticles on the oxidation of malachite green by hexacyanoferrate (III) in acetate–acetic acid medium. The absorbance is measured at 610 nm with the fixed-time method. Under the optimum conditions, the linear range was 8.0?×?10?9–2.0?×?10?7?mol?L?1 malachite green with a correlation coefficient of 0.996. The limit of detection (S/N?=?3) was 2.0?×?10?9?mol?L?1. Relative standard deviation for ten replicate determinations of 1.0?×?10?8?mol?L?1 malachite green was 1.86 %. The method is featured with good accuracy and reproducibility for malachite green determination in surface water samples without any pre-concentration and separation step.  相似文献   

3.
A simple, sensitive, and accurate UV spectrophotometric method has been developed for the determination of nickel in synthetic mixture and water samples. The method is based on the complexation reaction of nickel ion with cefixime, thus leading to the formation of Ni–cefixime complex in ethanol-distilled water medium at room temperature. The complex showed the maximum absorption wavelength at 332 nm. Beer’s law is obeyed in the working concentration range of 0.447–4.019 μg?mL?1 with apparent molar absorptivity of 7.314?×?103?L?mol?1?cm?1 and Sandell’s sensitivity of 0.008 μg/cm2/0.001 absorbance unit. The limits of detection and quantitation for the proposed method are 0.016 and 0.054 μg?mL?1, respectively. The factors such as cefixime concentration and solvent affecting the complexation reaction were carefully studied and optimized. The method is validated as per the International Conference on Harmonisation guideline. The method is successfully applied to the determination of Ni(II) in synthetic mixture and wadi water samples collected from Al Rustaq. The same water samples are also analyzed by atomic absorption spectrophotometry. Both methods determined the amount of Ni(II) in water sample and found to be approximately the same.  相似文献   

4.
A simple, rapid, and efficient dispersive liquid–liquid microextraction method, followed by UV–Vis spectrophotometry was developed for the preconcentration and determination of Pd ions in water samples. Pd ions react with α-furildioxime (chelating agent) to form a hydrophobic complex. Various parameters were altered to study and optimize their effects on the extraction efficiency, such as pH, ligand concentration, the type and volume of extraction and dispersive solvents, extraction time, and salt concentration. Under optimized conditions, the method exhibited an enrichment factor (C org/C aq) of 25 and recovery more than 98 % within a very short extraction time. The linearity of the method ranged from 10 to 200 μg?L?1. The limit of detection was 1.1 μg?L?1. The relative standard deviation for the concentration of 100 μg?L?1 of Pd was 2.3 % (n?=?10). Finally, the developed method was successfully applied to the extraction and determination of Pd in tap, river, mineral, and sea water samples.  相似文献   

5.
A simple, sensitive and reliable HPLC-FLD method for the routine determination of 4-nonylphenol, 4-NP and 4-tert-octylphenol, 4-t-OP content in water samples was developed. The method consists in a liquid–liquid extraction of the target analytes with dichloromethane at pH  3.0–3.5 followed by the HPLC-FLD analysis of the organic extract using a Zorbax Eclipse XDB C8 column, isocratic elution with a mixed solvent acetonitrile/water 65:35, at a flow rate of 1.0 mL/min and applying a column temperature of 40°C. The method was validated and then applied with good results for the determination of 4-NP and 4-t-OP in Ialomi?a River water samples collected each month during 2006. The concentration levels of 4-NP and 4-t-OP vary between 0.08–0.17 μg/L with higher values of 0.24–0.37 μg/L in the summer months for 4-NP, and frequently <0.05 μg/L but also between 0.06–0.09 μg/L with higher values of 0.12–0.16 μg/L in July and August for 4-t-OP and were strongly influenced by sesonial and anthropic factors. The method was also applied on samples collected over 2 years 2007 and 2008 from urban wastewaters discharged into sewage or directly into the rivers by economic agents located in 30 Romanian towns. Good results were obtained when the method was used for analysis of effluents discharged into surface waters by 16 municipal wastewater treatment plants, during the year 2008.  相似文献   

6.
In this paper, a simple and sensitive spectrophotometric method for the determination of nanomolar level of bromate, based on the catalytic effect of silver nanoparticles on the oxidation of acid red 14 by potassium bromate, is described. The reaction rate was monitored spectrophotometrically by measuring the decrease in absorbance of acid red 14 at 516 nm. The detection limit of the method was 8 ng/mL, and the linear range was between 15 and 130 ng/mL. The effects of acidity, concentration of reactants and reaction time, and external ions were also discussed. The optimum reaction conditions were fixed, and some kinetic parameters determined. The relative standard deviation for the determination of bromate at the concentration of 50 ng/mL was calculated to be 0.996 % (n?=?10). The method has been successfully applied to the determination of bromate in flours and bottled waters.  相似文献   

7.
A new, simple, sensitive, and selective spectrophotometric method for the determination of copper in water and soil samples has been demonstrated. The method is based on the reaction of Cu(I) with neocuproine (2,9-dimethyl-1, 10-phenanothroline) and extracted with N-phenyl benzimidoylthiourea in chloroform. The value of molar absorptivity of the complex in the term of Cu(I) is 1.45 × 105 L mol???1 cm???1 at λ max 460 nm in chloroform. The detection limit of copper in water and soil is 2 ng mL???1 and 4 ng g???1, respectively. The method is free from the interference of the ions commonly found to be associated with the copper determination in water and soil samples. The application of the proposed method has been successfully tested for the determination of copper in different types of water and soil samples.  相似文献   

8.
This study performed on randomly selected seven sample plots in leguminous black locust (Robinia pceudoacacia L.) plantations and five sample plots in umbrella pine (Pinus pinea L.) plantations on coal mine soil/spoils. Soil samples were taken from eight different soil depths (0–1, 1–3, 3–5, 5–10, 10–20, 20–30, 30–40, and 40–50 cm) into the soil profile. On soil samples, bulk density, fine soil fraction (Ø < 2 mm), sand, silt and clay rates, soil acidity (pH), organic carbon (Corg), and total nitrogen (Nt) contents were investigated. Also, some forest floor properties (unit mass, organic matter, and total nitrogen) were determined, and results were compared statistically between umbrella pine and black locust. As a result, 17 years after plantations, total forest floor accumulation determined as 6,107 kg ha???1 under black locust compared to 13,700 kg ha???1 under umbrella pine. The more rapid transformation of leguminous black locust forest floor creates organic carbon that migrates further into the mineral profile, and rapid accumulation of C and N in the soil profile was registered. Slower transformation processes of forest floor under umbrella pine result in lower soil N ratio and greater quantity of forest floor. Higher soil pH under leguminous black locust was determined significantly than umbrella pine. In conclusion, the composition of symbiotic nitrogen fixation of black locust appears to be a possible factor favoring carbon and nitrogen accumulation and, consequently, soil development. Clearly, both tree species have favorable impacts on initial soil formation. The umbrella pine generates the more forest floor layer; in contrast, black locust forest floor incorporates into the soil more rapidly and significantly increases soil nitrogen in upper soil layers.  相似文献   

9.
In this study, an ultra-sensitive and highly selective, rapid flow-injection spectrophotometric method for the determination of iron (II) and total iron has been proposed. The method was based on the reaction between iron (II) and 2′, 3, 4′, 5, 7-pentahydroxyflavone in slightly acidic solution with a strong absorption at 415 nm. The carrier solution used was 1?×?10?5 M 2′, 3, 4′, 5, 7-pentahydroxyflavone in 0.1 M HAc/Ac? buffer solution at pH 4.5. Parameters that affect simultaneously the determination of iron (II) and interfering ions were tested. The relative standard deviation for the determination of 50 μg L?1 iron (II) was 0.85 % (n?=?10), and the limit of detection (blank signal plus three times the standard deviation of the blank) was 3 μg L?1, both based on injection volumes of 20 μL. The method has been successfully applied to the determination of iron (II) and total iron in water samples and ore samples. The method was verified by analysing a certified reference material Zn/Al/Cu 43XZ3F.  相似文献   

10.
A new kinetic method has been developed for the determination of nitrite in fruit juice samples. The method is based on the catalytic effect of nitrite with the oxidation of Nile Blue A (NBA) by KBrO3 in the sulfuric acid medium. The optimum conditions obtained are 1.2 mM sulfuric acid, 0.034 mM of NBA, 2.8?×?10?3 M KBrO3, reaction temperature of 20 °C, and reaction time of 100 s at 595.5 nm. Under the optimized conditions, the method allowed the quantification of nitrite in a range of 0.2–800 μg/mL with a detection limit of 0.02 μg/mL. The method was applied to the determination of nitrite in 15 brands of fruit juice samples.  相似文献   

11.
A simple and sensitive method based on a modified hollow-fiber liquid-phase microextraction followed by gas chromatography–mass spectrometry has been successfully developed for the extraction and simultaneous derivatization of some nitrophenols (NPs) in soil and rain samples. Microwave-assisted solvent extraction was used for the extraction of NPs from the soil, while the rain sample was directly applied to the previously mentioned method. Briefly, in this method, the analytes were extracted from aqueous samples into a thin layer of organic solvent (dodecane?+?10 % tri-n-octylphosphine oxide) sustained in the pores of a porous hollow fiber. Then, they were back-extracted using a small volume of organic acceptor solution (25 μl; 10 mg/L N-methyl-N-(trimethylsilyl)trifluoroacetamide, as derivatization reagent, in acetonitrile) that was located inside the lumen of the hollow fiber. Under the optimized extraction conditions, enrichment factors of 255 to 280 and limits of detection of 0.1 to 0.2 μg/L (S/N?=?3) with dynamic linear ranges of 1–100 μg/L were obtained for the analytes. The accuracy of the approach was tested by the relative recovery experiments on spiked samples, with results ranging from 93 to 113 %. The method was shown to be rapid, cost-effective, and potentially interesting for screening purposes.  相似文献   

12.
This study reports the feasibility of applying directly suspended liquid-phase microextraction (DSLPME)-gas chromatography detection for the pre-concentration and determination of low levels of eight polychlorinated biphenyls (PCBs) in aqueous samples. The technique requires minimal sample preparation, analysis time and solvent consumption and represents significant advantages over conventional analytical methods. The experimental parameters such as salt content, sample temperature, stirring rate, extraction time, micro-drop volume and breakthrough volume were investigated and found to have significant influences on DSLPME. Under the optimal experimental conditions, the enrichment factor ranged from 578 to 729, and the recovery was above 93 %. Calibration curves possessed good linearity (R 2?>?0.99) over a wide concentration range of 0.1–10.0 μg L?1 with limits of detection ranging from 0.01 to 0.07 μg L?1. The relative standard deviations for 1.0 μg L?1 of PCBs in water by using internal standard were in the range 2–14 % (n?=?3). The proposed simple, accurate and sensitive analytical method was applied successfully to the determination of trace amounts of PCBs in water samples.  相似文献   

13.
The use of natural resources for the removal of phenol and phenolic compounds is being looked upon by researchers in preference to other prevailing methods. In the present study, different biosorbents, brown algae (Padina pavonia), fresh water macrophyta (Ceratophyllum demersum), and black tea residue, were tested as adsorbent for the removal of phenol from aqueous solutions. The optimum conditions for maximum adsorption in terms of concentration of the adsorbate and pH were identified. The results show that the initial concentration increases as the removal of phenol increases in C. demersum; in the case of the other two adsorbents, the initial concentration increases as the removal of phenol decreases, especially for an initial concentration lower than 100 and 1,000 μg/L for P. pavonia and black tea residue, respectively. Maximum percentage removal of phenol by each adsorbent is 77, 50.8, and 29 % for C. demersum, P. pavonia, and black tea residue, respectively. Also, the biosorption capacity was strongly influenced by the pH of the aqueous solution with an observed maximum phenol removal at pH of around 6–10. The first biosorbent (black tea residue) displays the maximum adsorption capacity at a pH of 10 with a percentage sorption capacity of 84 %; P. pavonia revealed a greater adsorption percentage at pH?10, reaching 30 %, while for C. demersum, the removal of phenol increases with the increase in initial pH up to 6.0 and decreases drastically with further increase in initial pH. The Freundlich, Langmuir, and Brauner–Emmet–Teller adsorption models were applied to describe the equilibrium isotherms. The results reveal that the equilibrium data for all phenol adsorbents fitted the Freundlich model which seemed to be the best-fitting model for the experimental results with similar values of coefficient of determination.  相似文献   

14.
Silver is subject to significant interferences caused by high chloride concentrations in electrothermal atomic absorption spectrometry, thus its direct determination in aqua regia leaches from soils, sediments, and sludges is very difficult, especially when using instrumentation equipped with deuterium-lamp background correction (D2). In this study, the interference of the aqua regia medium was successfully eliminated using Pd–citric acid chemical modifier. This chemical modifier was found to be the most advantageous in comparison with Pd mixture with ascorbic acid, tartaric acid, or citric acid–Li based on its ability to suppress the interference originating from different chloride matrix. Palladium increases the analyte stability; citric acid serves as a reducing reagent, and furthermore, it helps to remove the interfering chlorides by forming HCl, in the drying step of the electrothermal program. In the presence of the modifier, the pyrolysis temperature can be adjusted up to 1,000 °C with no loss of the analyte. The obtained limit of detection and characteristic mass were 5 ng g?1 and 1.7 pg, respectively. The accuracy of the method was verified by means of six different reference samples and by comparing the results of the analysis of real samples with those obtained by inductively coupled plasma orthogonal acceleration time-of-flight mass spectrometer. The proposed method was applied to the Ag determination in soils, sediments, and sewage sludge samples from the Pardubice region in Czech Republic.  相似文献   

15.
A new kinetic method has been developed for the determination of iodine in water samples. The method is based on the catalytic effect of I? with the oxidation of Indigo Carmine (IC) by KBrO3 in the sulfuric acid medium. The optimum conditions obtained are 0.16 M sulfuric acid, 1?×?10?3 M of IC, 1?×?10?2 M KBrO3, reaction temperature of 35°C, and reaction time of 80 s at 612 nm. Under the optimized conditions, the method allowed the quantification of I? in a range of 12–375 ng/mL with a detection limit of 0.46 ng/mL. The method was applied to the determination of iodine in river and city water samples with the satisfactorily results.  相似文献   

16.
A colorimetric assay method is described for the environmental detection of 2-mercaptobenzimidazole (MBI) using surface plasmon resonance of gold nanoparticles (AuNPs). Stable and dispersed AuNPs with intensified plasmon resonance were prepared in situ using a simple, rapid, and eco-friendly procedure by applying ascorbic acid as a reducer and cetyltrimethylammonium bromide as a stabilizer. The presence of MBI has a strong effect on the plasmon absorbance of AuNPs, which was employed for the detection of MBI. The calibration curve was linear in the range of 1.0?×?10?6–5.5?×?10?5 mol/L of MBI; the detection limit was 8.4?×?10?7 mol/L. The relative standard deviations for eight replicate measurements of 3.0?×?10?6 and 5?×?10?5 mol/L MBI were 3.9 and 1.4 %, respectively. The method was successfully applied to the determination of MBI in tap, river, sea, and heat exchanger cooling water samples.  相似文献   

17.
In this research, a microfunnel-assisted headspace liquid-phase microextraction technique has been used in combination with hydride generation to determine arsenic (As) by UV–Vis spectrophotometry. The method is based on the reduction of As to arsine (AsH3) in acidic media by sodium tetrahydroborate (NaBH4) followed by its subsequent reaction with silver diethyldithiocarbamate (AgDDC) to give an absorbing complex at 510 nm. The complexing reagent (AgDDC) has been dissolved in a 1:1 (by the volume ratio) mixture of chloroform/chlorobenzene microdroplet and exposed to the generated gaseous arsine via a reversed microfunnel in the headspace of the sample solution. Several operating parameters affecting the performance of the method have been examined and optimized. Acetonitrile solvent has been added to the working samples as a sensitivity enhancement agent. Under the optimized operating conditions, the detection limit has been measured to be 0.2 ng mL?1 (based on 3sb/m criterion, n b?=?8), and the calibration curve was linear in the range of 0.5–12 ng mL?1. The relative standard deviation for eight replicate measurements was 1.9 %. Also, the effects of several potential interferences have been studied. The accuracy of the method was validated through the analysis of JR-1 geological standard reference material. The method has been successfully applied for the determination of arsenic in raw and spiked soft drink and water samples with the recoveries that ranged from 91 to 106 %.  相似文献   

18.
Hexavalent chromium (Cr(VI)) is an acknowledged hazardous material in drinking waters. As such, effective monitoring and assessment of the risks posed by Cr(VI) are important analytical objectives for both human health and environmental science. However, because of the lack of highly sensitive, rapid, and simple procedures, a relatively limited number of studies have been carried out in this field. Here we report a simple and sensitive analytical procedure of flow injection analysis (FIA) for sub-nanomolar Cr(VI) in drinking water samples with a liquid core waveguide capillary cell (LWCC). The procedure is based on a highly selective reaction between 1, 5-diphenylcarbazide and Cr(VI) under acidic conditions. The optimized experimental parameters included reagent concentrations, injection volume, length of mixing coil, and flow rate. Measurements at 540 nm, and a 650-nm reference wavelength, produced a 0.12-nM detection limit. Relative standard deviations for 1, 2, and 10 nM samples were 5.6, 3.6, and 0.72 % (n?=?9), and the analysis time was <2 min sample?1. The effects of salinity and interfering ions, especially Fe(III), were evaluated. Using the FIA-LWCC method, different sources of bottled waters and tap waters were examined. The Cr(VI) concentrations of the bottled waters ranged from the detection limit to ~20 nM, and tap waters collected from the same community supply had Cr(VI) concentration around 14 nM.  相似文献   

19.
Monitoring of microalgae in water supplies and industrial applications are becoming increasingly important, yet there are few options available that are simple and accurate, and can provide real-time information. The present work illustrates a new method to determine the concentration of microalgae in water and wastewater using spectrophotometry and the first derivative of absorbance. Chlorella vulgaris was used as an indicator microalga, spiked in water samples representing a range of water qualities (distilled water, surface water, and wastewater), and correlations among C. vulgaris concentrations, absorbance, and the first derivative of absorbance measurements were investigated. In addition, detection limits were established and sensitivity analyses were carried out to determine the lowest C. vulgaris concentrations that can be confidently measured in different water matrices. Finally, the study compared the performance and detection limits of the spectrophotometry-based methods with the well-accepted chlorophyll extraction method. A strong linear relationship (R2?>?0.97) was found between C. vulgaris concentration and absorbance at 695 nm. Using the first derivative of absorbance improved C. vulgaris detection limits by reducing the effects of the background noise and interferences from other substances. The detection limits established using the first derivative method were 0.47, 0.56, and 1.96 mg TVS/L in distilled water, surface water, and wastewater, respectively. In comparison, the detection limits of the chlorophyll extraction method were found to be 19.6, 38.6, and 48.3 mg TVS/L in the same water matrices. These results indicate that first derivative of absorbance can be successfully used for monitoring of microalgae in surface waters and environmental samples as well as in bioreactors used for microalgae cultivation in industrial applications.  相似文献   

20.
The aim of this study was the development of analytical methods for the simultaneous determination of 25 selected pharmaceuticals, metabolites, and pesticides, belonging to the various chemical classes, in river sediments and their corresponding surface and ground water with the purpose of monitoring the contamination levels. The methods were based on the solid-phase extraction as the sample preparation method for water samples, and the ultrasonic solvent extraction for the sediment samples, followed by the liquid chromatography–tandem mass spectrometry. High recoveries were achieved for extraction from both water and sediment samples for the majority of analytes. Low limits of detection were achieved for all investigated compounds in the water sample (1–5 ng L?1) as well as in the sediment (1–3 ng g?1). Applicability of the developed methods was demonstrated by determination of pharmaceutical and pesticide residues in 30 surface water, 44 groundwater, and 5 sediment samples from the Danube River Basin in Serbia. Sixty percent of target compounds were detected in environmental samples. The most frequently detected analytes in river sediments were the pesticides dimethoate and atrazine, while carbamazepine and metamizole metabolites 4-AAA and 4-FAA were the most frequently found in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏