首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Two new pre-treatment methods (water-washing/carbonation and carbonation/phosphate stabilization) of municipal solid waste (MSW) incinerator residues were evaluated by column leaching tests under aerobic conditions and anaerobic conditions (which were changed to aerobic conditions after 10 months). A mixture of bottom ash and fly ash (5:1 ratio) was pre-treated using each method. Shredded incombustible residues (SIR) were added to each ash preparation in proportions similar to the ratios present in landfills. For comparison, landfill wastes typical of Japan, namely, a mixture of bottom ash, chelating-pre-treated fly ash, and SIR, were also examined. Leachate samples were collected periodically and analysed over a 15-month period. When compared with chelating pretreatment, both water-washing/carbonation and carbonation/ phosphate stabilization reduced the leaching of Pb, Al, and Cu by about one to two orders of magnitude. Moreover, the initial concentrations of Ca and Pb in leachates from column of water-washing/carbonation were 56-57% and 84-96% less than those from the column of carbonation/phosphate stabilization. Therefore, water-washing/carbonation was considered to be a promising approach to obtain early waste stabilization and to reduce the release of heavy metals to near-negligible levels. The leaching behaviour of elements was also discussed.  相似文献   

2.
Leaching tests on flue gas ashes from waste incineration showed low leaching of Cr from ashes that under moist anaerobic conditions also produced hydrogen gas. In some cases, also the redox levels (aerobic/anaerobic conditions) during the leaching test affected Cr leaching. Aerobic ashes tested in an open batch leaching test leached Cr up to 2-3 orders of magnitude more than the ashes kept moist under anaerobic conditions and tested in a closed leaching test. Model experiments showed that metallic Al could reduce Cr and at the same time produce H(2). The hydrogen gas per se could not reduce Cr. Laboratory experiments with ashes provided evidence that metallic Al, present naturally in the ashes or amended, could reduce Cr under moist anaerobic, but not under aerobic storage. Significant Cr reduction was linked to, but not caused by hydrogen formation. The reduced Cr seemed to be partially reoxidizable upon aeration or drying. The observations presented provide a basis for understanding the complexity of Cr leaching from waste incineration ashes, as for example, why some chemical stabilization methods increase Cr leaching, and point out the need for standardizing leaching test conditions with respect to Cr.  相似文献   

3.
Carbonization is a kind of pyrolysis process to produce char from organic materials under an inert atmosphere. In this work, chars derived from various solid wastes were characterized from the standpoint of fuel recovery and pretreatment of waste before landfilling. Sixteen kinds of municipal and industrial solid wastes such as residential combustible wastes, non-combustible wastes, bulky wastes, construction and demolition wastes, auto shredder residue, and sludges were carbonized at 500 degrees C for 1h under nitrogen atmosphere. In order to evaluate the quality of char as fuel, proximate analysis and heating value were examined. The composition of raw waste had a significant influence on the quality of produced char. The higher the ratio of woody biomass in waste, the higher heating value of char produced. Moreover, an equation to estimate heating value of char was developed by using the weight fraction of fixed carbon and volatile matter in char. De-ashing and chlorine removal were performed to improve the quality of char. The pulverization and sieving method seems to be effective for separation of incombustibles such as metal rather than ash. Most char met a 0.5 wt% chlorine criterion for utilization as fuel in a shaft blast furnace after it was subjected to repeated water-washing. Carbonization could remove a considerable amount of organic matter from raw waste. In addition, the leaching of heavy metals such as chrome, cadmium, and lead appears to be significantly suppressed by carbonization regardless of the type of raw waste. From these results, carbonization could be considered as a pretreatment method for waste before landfilling, as well as for fuel recovery.  相似文献   

4.
Environmental assessment of residue disposal needs to account for long-term changes in leaching conditions. Leaching of heavy metals from incineration residues are highly affected by the leachate pH; the overall environmental consequences of disposing of these residues are therefore greatly influenced by changes in pH over time. The paper presents an approach for assessing pH changes in leachate from municipal solid waste incineration (MSWI) air-pollution-control (APC) residues. Residue samples were subjected to a stepwise batch extraction method in order to obtain residue samples at a range of pH values (similar to common pH-dependence tests), and then on these samples to determine leaching of alkalinity as well as remaining solid phase alkalinity. On a range of APC residues covering various pretreatment and disposal options, this procedure was used to determine leachable and residual alkalinity as a function of pH. Mass balance calculations for typical disposal scenarios were used to provide data on pH as a function of the liquid-to-solid (L/S) ratio in the leaching system. Regardless of residue type and pretreatment, pH was found to stay above 7 for L/S ratios up to about 2000 L kg(-1) corresponding to about 100,000 years in typical landfill scenarios. It was found that pH changes were mainly governed by alkalinity decreases from leaching processes rather than neutralization reactions. The results suggest that leaching testing for assessment purposes should be carried out in the alkaline range, for example, at pH 9. The paper offers a thorough basis for further modelling of incineration residue leaching and for modelling the environmental consequences of landfilling and utilization of these residues.  相似文献   

5.
Bottom ash is the main solid residue (in weight) which is produced by municipal solid waste incineration (MSWI) facilities. This material is composed of a mineral matrix and may be used as secondary raw material for construction purpose. However, for this specific application the leaching behavior of the environmentally relevant elements under field conditions is different from the predicted behavior based on results obtained from the standardized leaching test. Therefore, a 70-day simulative experiment has been carried out in this study to investigate the release of major heavy metals (Cu and Pb) and polycyclic aromatic hydrocarbons (PAHs) from several particle fractions of bottom ash under a static leaching condition, where bottom ash was immersed in water at different initial pH values. Results showed that: (1) the leaching behavior of Cu and Pb was much similar with that depicted by the standardized leaching tests, and fit well with the solubility-controlling mechanism; (2) the sorption mechanism on the neoformed phases may control the solubility of Pb, whereas the dissolved organic carbon (DOC) may play an important role in the solubility of Cu; and (3) the leached PAHs were degraded during the later period of leaching process.  相似文献   

6.
Dissolved organic carbon (DOC) may affect the transport of pollutants from incineration residues when landfilled or used in geotechnical construction. The leaching of dissolved organic carbon (DOC) from municipal solid waste incineration (MSWI) bottom ash and air pollution control residue (APC) from the incineration of waste wood was investigated. Factors affecting the mobility of DOC were studied in a reduced 2(6-1) experimental design. Controlled factors were treatment with ultrasonic radiation, full carbonation (addition of CO2 until the pH was stable for 2.5h), liquid-to-solid (L/S) ratio, pH, leaching temperature and time. Full carbonation, pH and the L/S ratio were the main factors controlling the mobility of DOC in the bottom ash. Approximately 60 weight-% of the total organic carbon (TOC) in the bottom ash was available for leaching in aqueous solutions. The L/S ratio and pH mainly controlled the mobilization of DOC from the APC residue. About 93 weight-% of TOC in the APC residue was, however, not mobilized at all, which might be due to a high content of elemental carbon. Using the European standard EN 13 137 for determination of total organic carbon (TOC) in MSWI residues is inappropriate. The results might be biased due to elemental carbon. It is recommended to develop a TOC method distinguishing between organic and elemental carbon.  相似文献   

7.
The changes in waste management policy caused by the massive generation of waste materials (e.g. construction and demolition waste material, municipal waste incineration products) has led to an increase in the reuse and recycling of waste materials. For environmental risk assessment, test procedures are necessary to examine waste materials before they can be reused. In this article, results of column and lysimeter leaching tests having been applied to inorganic compounds in a reference demolition waste material are presented. The results show a good agreement between the leaching behaviour determined with the lysimeter unit and the column units used in the laboratory. In view of less time and system requirements compared to lysimeter systems, laboratory column units can be considered as a practicable instrument to assess the time-dependent release of inorganic compounds under conditions similar to those encountered in a natural environment. The high concentrations of elements in the seepage water at the initial stage of elution are reflected by the laboratory column leaching tests. In particular, authorities or laboratories might benefit and have an easy-to-use, but nevertheless reliable, method to serve as a basis for decision-making.  相似文献   

8.
When reusing or disposing of contaminated granular waste materials there is a need to evaluate how the contaminants will interact on the pathway soil–groundwater and the effect this interaction will have on the surrounding environment. While column testing can provide a closer approximation to field percolation conditions than batch testing, there is still a need to develop column testing procedures that consider the requirements of practical testing time frames. This study evaluates the effect of different column contact times (2.5, 5, and 16 h) on the release of inorganic constituents from bottom ash and demolition waste, two commonly reused granular materials. Leaching data for representative constituents of concern, such as copper, chromium, sulfate and chloride, as well as pH and electrical conductivity was compared for all different contact times studied.Results for the materials investigated in this study showed that variations in contact time have no significant effect on the release of the selected constituents and leaching parameters at low liquid to solid ratios. However, after a liquid to solid ratio of 1 L/kg, the effect is more noticeable, and higher contact times show lower pH values as well as a reduction in the release of constituents of concern from bottom ash. In the case of demolition waste, the variation of contact time did not have a strong effect on the leaching behavior.  相似文献   

9.
This study aimed to identify the metal flow in a municipal solid waste (MSW) management system. Outputs of a resource recovery facility, refuse derived fuel (RDF) production facility, carbonization facility, plastics liquefaction facility, composting facility, and bio-gasification facility were analyzed for metal content and leaching concentration. In terms of metal content, bulky and incombustible waste had the highest values. Char from a carbonization facility, which treats household waste, had a higher metal content than MSW incinerator bottom ash. A leaching test revealed that Cd and Pb in char and Pb in RDF production residue exceeded the Japanese regulatory criteria for landfilling, so special attention should be paid to final disposal of these substances. By multiplying metal content and the generation rate of outputs, the metal content of input waste to each facility was estimated. For most metals except Cr, the total contribution ratio of paper/textile/plastics, bulky waste, and incombustible waste was over 80%. Approximately 30% of Cr originated from plastic packaging. Finally, several MSW management scenarios showed that most metals are transferred to landfills and the leaching potential of metals to the environment is quite small.  相似文献   

10.
Column leaching testing can be considered a better basis for assessing field impact data than any other available batch test method and thus provides a fundamental basis from which to estimate constituent release under a variety of field conditions. However, column testing is time-intensive compared to the more simplified batch testing, and may not always be a viable option when making decisions for material reuse. Batch tests are used most frequently as a simple tool for compliance or quality control reasons. Therefore, it is important to compare the release that occurs under batch and column testing, and establish conservative interpretation protocols for extrapolation from batch data when column data are not available. Five different materials (concrete, construction debris, aluminum recycling residue, coal fly ash and bottom ash) were evaluated via batch and column testing, including different column flow regimes (continuously saturated and intermittent unsaturated flow). Constituent release data from batch and column tests were compared. Results showed no significant difference between the column flow regimes when constituent release data from batch and column tests were compared. In most cases batch and column testing agreed when presented in the form of cumulative release. For arsenic in carbonated materials, however, batch testing underestimates the column constituent release for most LS ratios and also on a cumulative basis. For cases when As is a constituent of concern, column testing may be required.  相似文献   

11.
Two types of leaching tests were performed on the bottom ash from municipal solid waste incinerators. A short-term batch test specified by the America Nuclear Society (ANS) and long-term column tests with acetic acid (pH 5.2) as leaching solution were used to evaluate copper leachability. The Cu leaching after the 5-d ANS test is about 1% of the original Cu content of 5300 mg/kg. Upon addition of a stabilizing agent, the Cu leaching quantity is reduced; the extent of reduction depends on the type of chemical used (phosphate, carbonate and sulfide). The 1.6% Na(2)S addition showed negligible Cu leaching, and Na(2)S was, therefore, used in subsequent column tests. The 30-d column test indicates a steady increase of Cu leaching amount with time and reaches about 1.5% of the original Cu content after 30 d. A 180-d column test further increased the Cu leaching to about 5.1% of the original Cu content, whereas no appreciable Cu leaching was found with the addition of 1.6% Na(2)S. A sequential extraction was conducted on the raw ash, ash with the addition of Na(2)S and the residue ash after 30 d of operation to characterize Cu affinity for different solid fractions. The data were used to evaluate the fate of Cu through these interactions.  相似文献   

12.
Air-pollution-control (APC) residues from waste incinerators are hazardous waste according to European legislation and must be treated prior to landfilling. Batch and column leaching data determine which type of landfill can receive the treated APC-residues. CEN standards are prescribed for the batch and column leaching test; however, these standards do not specify whether or not the residue samples should be dried prior to the leaching testing. Laboratory tests were performed in parallel (dried/non-dried) on treated APC-residue samples and evaluated with respect to Cr, Cd, Cu, Pb and Zn leaching. The effect of drying of the wet APC-residue samples was particularly dramatic regarding the leaching of Cr. Drying resulted in 10-100 times more Cr leaching in both batch and columns test. Drying also affected the leaching of Cd, Cu and Pb. Initial Cd leaching was up to 100 times higher in column tests with dried APC-residue than in tests with wet residues. The effect of drying appeared to be a combination of decreasing the reduction capacity of the sample (Cr), decreasing pH (Cd, Cu) and in column tests also a wash-out of salts (probably affecting Cd and Pb). If the leaching tests are intended to mimic landfill conditions, the results of this paper suggest that the tests should be done on wet, non-dried residue samples, although this may be less practical than testing dried samples.  相似文献   

13.
The leaching behavior of dioxins from landfill containing bottom ash and fly ash from municipal solid waste incineration has been investigated by leaching tests with pure water, non-ionic surfactant solutions, ethanol solutions, or acetic acid solutions as elution solvents for a large-scale cylindrical column packed with ash. Larger amounts of dioxins were eluted from both bottom ash and fly ash with ethanol solution and acetic acid solution than with pure water. Large quantities of dioxins were leached from fly ash but not bottom ash by non-ionic surfactant solutions. The patterns of distribution of the dioxin congeners in the leachates were very similar to those in the bottom ash or fly ash from which they were derived.  相似文献   

14.
Characterization of the leaching behavior of wastes is a crucial step in the environmental assessment for reuse or disposal scenarios. The release of inorganic contaminants from waste materials is typically evaluated by tank leaching of continuously water-saturated material. However, materials, in many field or management scenarios, experience cyclic wetting and drying under varied environmental conditions (i.e. variable relative humidity, atmospheric CO2 or CO2 from biologic activities). During periods of storage in an unsaturated environment, many processes may occur that can influence the release potential and release rate of inorganic constituents. The research presented here was carried out to examine how the phenomena of carbonation during drying influence the release of inorganic contaminants from Portland cement-based materials during cyclic wetting and storage. Batch equilibrium leaching tests were used to determine constituent solubility as a function of pH. Dynamic leaching tests on monolithic material were carried out to determine the rate of constituent release as a function of leaching time and intermittent storage conditions. This paper presents the results observed for three typical waste constituents, arsenic, cadmium and lead.  相似文献   

15.
Evaluation of leaching and extraction procedures for soil and waste   总被引:1,自引:1,他引:0  
Laboratory leaching tests may be used for source term determination as a basis for risk assessment for soil-groundwater pathways on contaminated sites. In order to evaluate different leaching procedures, batch extraction tests and percolation tests were performed using three reference materials produced from contaminated soil, demolition waste and municipal solid waste incinerator bottom ash. Emphasis was placed on the investigation of the leachability of the heavy metals copper and chromium, polycyclic aromatic hydrocarbons (PAHs) and the anions chloride and sulfate. Significant discrepancies between column experiments and batch/extraction tests were found for the release of PAHs and to a lesser extent for the heavy metals Cu and Cr. Additionally interlaboratory comparisons were conducted based on different leaching tests with the reference materials and evaluated using the criteria of comparability and reproducibility. The best reproducibility was achieved for all investigated substances in column tests. The reproducibility of batch tests was acceptable except for PAHs. The results from the experimental work will help establish standardized and feasible laboratory procedures as fundamental for substance specific risk assessment of contaminated sites.  相似文献   

16.
In order to manage municipal solid waste incineration (MSWI) bottom ash safely, risk assessments, including the prediction of leaching under different field conditions, are necessary. In this study, the influence of salt or dissolved organic matter (DOM) in the influent on metal leaching from MSWI bottom ash was investigated in a column experiment. The presence of salt (0.1M NaCl) resulted in a small increase of As leaching, whereas no impact on leachate concentration was found when lakewater DOM (35.1mg/l dissolved organic carbon) was added. Most of the added DOM was retained within the material. Further, X-ray spectroscopy revealed that Cu(II) was the dominating form of Cu and that it probably occurred as a CuO-type mineral. The Cu(2+) activity in the MSWI bottom ash leachate was most likely determined by the dissolution of CuO together with the formation of Cu-DOM complexes and possibly also by adsorption to (hydr)oxide minerals. The addition of lake DOM in the influent resulted in lower saturation indices for CuO in the leachates, which may be due to slow CuO dissolution kinetics in combination with strong Cu-DOM complexation.  相似文献   

17.
Leaching tests are becoming more relevant in assessing solid waste material, particularly with respect to groundwater risks. In the field, water infiltration is the dominant leaching mechanism, which is simulated in the lab with batch and column tests. In this study, we compared percolation, through analytical solutions of the advection–dispersion equation, to laboratory batch and sequential leaching tests. The analytical solutions are supported with comprehensive data from various field and laboratory leaching of different solutes from waste materials and soils collected in long-term joint research projects funded by the German Federal Ministry for Education and Research and the Federal Environment Agency. The comparison of theory and data is facilitated if concentrations and cumulative release are plotted versus the liquid–solid ratios (LS). Both theory and data indicate that leaching behaviour is independent of duration and physical dimensions of the leaching tests. This holds even if field lysimeters are compared to laboratory columns of different size, different flow velocities as well as different contact times. In general, laboratory batch tests over predict effluent concentrations (for LS < Kd). Leaching of solutes from solid samples of certain materials (e.g. chloride from incineration ashes or sulphate from demolition waste) in column and lysimeter tests compares very well and agrees with the analytical solutions. Overall, reproducibility and agreement with theory of column tests are better than batch tests, presumably because the latter are prone to artefacts (e.g. in liquid–solid separation steps). Theory and data fit surprisingly well, despite the fact that the theory is based on the local equilibrium assumption; non-linear sorption and chemical reactions in the solid waste materials are not considered.  相似文献   

18.
Hydrothermal carbonization (HTC) is a novel thermal conversion process that may be a viable means for managing solid waste streams while minimizing greenhouse gas production and producing residual material with intrinsic value. HTC is a wet, relatively low temperature (180-350 °C) thermal conversion process that has been shown to convert biomass to a carbonaceous residue referred to as hydrochar. Results from batch experiments indicate HTC of representative waste materials is feasible, and results in the majority of carbon (45-75% of the initially present carbon) remaining within the hydrochar. Gas production during the batch experiments suggests that longer reaction periods may be desirable to maximize the production of energy-favorable products. If using the hydrochar for applications in which the carbon will remain stored, results suggest that the gaseous products from HTC result in fewer g CO(2)-equivalent emissions than the gases associated with landfilling, composting, and incineration. When considering the use of hydrochar as a solid fuel, more energy can be derived from the hydrochar than from the gases resulting from waste degradation during landfilling and anaerobic digestion, and from incineration of food waste. Carbon emissions resulting from the use of the hydrochar as a fuel source are smaller than those associated with incineration, suggesting HTC may serve as an environmentally beneficial alternative to incineration. The type and extent of environmental benefits derived from HTC will be dependent on hydrochar use/the purpose for HTC (e.g., energy generation or carbon storage).  相似文献   

19.
In this study, percolation and batch leaching tests were considered in order to characterize the behaviour of air pollution control (APC) residues produced in a municipal solid waste incinerator (MSWI) as a function of the liquid to solid ratio (L/S). This waste is hazardous, and taking into account their physical and chemical properties, leaching of contaminants into the environment is the main concern. In our work the leaching behaviour of toxic heavy metals (Pb, Zn, Cr, Ni and Cu) and inorganics associated with soluble salts (Na, K, Ca and Cl) was addressed. Although pH of the leaching solution is the most important variable, L/S may also play an important role in leaching processes. In our work, results from column and batch tests were compared in terms of concentration (mg/L) and releasing (mg/kg). The APC residues revealed to be hazardous according to both tests, and both Pb and Cl far exceeded the regulatory thresholds. The material exhibits high solubility, and when the liquid to solid ratio was high, more than 50% can be solubilised. The patterns of release may be in some cases availability or solubility controlled, and the former was easier to identify. When the results from column and batch experiments were compared by representing the cumulative released amounts (in mg/kg) as a function of L/S, both curves match for Zn, Ni, Cu, K, Na, Cl and Ca, but for Cr and Pb a significant difference was observed. In fact, the column experiments revealed that under percolation conditions it should be expected slow releasing of Pb along time. From this study, it can be concluded that the released amounts obtained in batch experiments for a certain L/S should be considered as the worst case for medium term. Some simple models proposed on the literature and based on local equilibrium assumption showed good fitting to experimental data for soluble species (non-reactive solutes).  相似文献   

20.
Waste incineration bottom ash and treated flue gas cleaning products mixed with 2.5% of cement (50 kg/m3) were tested in the laboratory in terms of compressive strength and tank leaching tests over a 64-day period. Although the material displayed lower mechanical strength than a reference concrete, the strength still was sufficient for use as a base layer for roads. The metal content in the incineration-residue-based specimens was up to 100 times higher than in the reference concrete, suggesting that the mixed waste incineration residue should be used only for dedicated purposes. The leaching of Cl and Na was increased by a factor of 20-100 from the incineration-residue-based specimens as compared to the reference, while the leaching of K, Ca and SO4 was increased by a factor of 2-10. The leaching of heavy metals was also higher from the incineration-residue-based specimens than from the reference with respect to Cu (50 times), Cd, Pb and Zn (5 times), but not with respect to Cr and Ni. The leaching curves did only allow for a closer evaluation of the leaching process in a few cases. The physical retention of the constituents seemed to be the same in the reference as in the incineration-residue-based specimens. Heavy metal leaching was limited by enhanced chemical retention in the incineration-residue-specimens as compared to the reference. Since no quality criteria in terms of leaching from a monolithic material are currently available, the leaching issue must be evaluated case by case.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号