首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
Intention, Goal, Scope, Background The effect of chloride concentration and pH on the UV oxidation systems was examined. Phenol and methanol were used as organic substances. The treatment of these chemicals by UV oxidation using a newly developed lab scale pretest UV-Free Surface Reactor (UV-FSR) with and without Cl– addition at different pH values, is evaluated. Results of this study indicated that the Cl– concentration of the water and the chemical structure of the substances is more important than the pH of the water. There was no AOX at the beginning of the experiments, but a de-novo synthesis of AOX was observed during the batch experiments. This is caused by the high chloride content of the wastewaters. It can be supposed that OHradicals oxidize some chloride-ions to form chlorine, which further reacts with organic compounds. During the treatment, these AOX compounds which are produced from the beginning of the reaction are destroyed again. Evaluations of these experiments were done according to TOC and AOX results. Approximately 80% and 99% TOC removal efficiencies were obtained for the treatment of Phenol and Methanol-containing wastewaters, respectively. Objective In the literature, there are no relevant publications concerning the AOX formation of wastewater by wet oxidation- iron catalysed or by application of UV. For that reason, the main objectives of this study were: 1. to see the influence of chloride concentration and pH on the AOXde-novo formation with newly developed UV-Free Surface Reactor (UV-FSR), 2. to make a comparison of different AOPs, 3. to observe the effect of the chloride concentration on the TOC degradation efficiency, 4. to optimise reaction conditions. Methods In synthetic wastewaters, Methanol (CH3OH) and Phenol (C6H5 OH) are used as pollutants. The concentration of each substance was 1000 mg/l and COD values were calculated theoretically. The H2O2 addition was calculated according to the COD with a convenient stoichiometric factor (e.g. 1). During experiments, the pH was always kept constant with the addition of either 25% H2SO4 or 33% NaOH depending on the experimental conditions. Each substance was treated with the addition of 1000 mg/l Cl–, 10000 mg/l Cl– and without Cl– addition at pH 3, pH 7 and pH 10, respectively. NaCl was used as a Cl– source. Adsorbable Organic Halogenides (AOX) were determined using a TOX analyser (European Standard EN 1485 H 14, 1996). TOC measurements were carried out using an Elementar High TOC Analyzer equipped with an auto sampler. The H2O2 concentration was measured according to German Standard Methods (DIN 38409, Part 15, 1987). Results and Discussion The first step was to determine the effect of pH on the AOX formation in the process. Therefore, experiments were carried out at three different pHs: acidic (pH 3), neutral (pH 7) and basic (pH 10) conditions at a constant initial Methanol concentration of 1000 mg/l and a hydrogen peroxide concentration of 3185 mg/l (1 x stoichiometric). All results were evaluated according to applied pH. At these conditions, the amount of H2O2 (53 ml / 10 l) concentration was nearly zero after 1 hour batch treatment of Methanol. There was no AOX at the beginning of the experiments, but the AOX value increased after 6–18 min. At the end of 1 hour batch treatment this produced AOX was treated again. The maximum AOX production was obtained with the addition of 10000 mg/l Cl–, whereas there is no AOX production during the experiment when Cl– was not used. In all studies, however, TOC values decreased to almost zero after 1 hour batch treatment. After the experiments with Methanol, Phenol treatment was carried out at different pHs as a second experiment. pH was kept constant with the addition of either H2SO4 or NaOH depending on the experimental conditions. During experiments with Phenol, the colour of the water changed from colourless to a yellowish- red. After 1 hour treatment, the colour of the water was red. Therefore, these experiments were continued until the water became colourless again, and this took about 5 hours. Although there was no AOX at the beginning of the experiments, it increased after 30 min to 1 hour oxidation with the addition of 1000 mg/l Cl– and 10000 mg/l Cl–. There was no AOX production during the experiments when Cl– was not added. At the end of 5 hours of treatment, formed AOX was degraded and the TOC concentration decreased from 766 mg/l to approximately 200 mg/l. Conclusion. These experiments of this study showed that the effects of Cl– concentration of the water and the chemical structure of the substances is more than that of the pH on the AOX formation. During the batch experiments, a de-novo synthesis of AOX was observed very impressively due to the high chloride content of the wastewaters. It can be implied that OH-radicals oxidize some chloride-ions to form chlorine, which further reacts with organic compounds so that AOXde-novo is formed. At the end of the reaction times these AOX compounds are also destroyed. Recommendation and Outlook It is more cost effective to use these processes for only purposes such as toxicity reduction, enhancement of biodegradability, decolourisation and removal of micropollutants. However, the most important point is the optimization of the reaction conditions for the process of concern. The AOP applied can be used, for instance, for AOX reduction and TOC removal of industrial wastewaters.  相似文献   

2.
Monteagudo JM  Durán A 《Chemosphere》2006,65(7):1242-1248
The decoloration and mineralization of the azo dye orange II under conditions of artificial ultraviolet light and solar energy concentrated by a Fresnel lens in the presence of hydrogen peroxide and TiO(2)-P25 was studied. A comparative study to demonstrate the viability of this solar installation was done to establish if the concentration reached in the focus of the Fresnel lens was enough to improve the photocatalytic degradation reaction. The degradation efficiency was higher when the photolysis was carried out under concentrated solar energy irradiation as compared to UV light source in the presence of an electron acceptor such us H(2)O(2) and the catalyst TiO(2). The effect of hydrogen peroxide, pH and catalyst concentration was also determined. The increase of H(2)O(2) concentration until a critical value (14.7 mM) increased both the solar and artificial UV oxidation reaction rate by generating hydroxyl radicals and inhibiting the (e(-)/h(+)) pair recombination, but the excess of hydrogen peroxide decreases the oxidation rate acting as a radical or hole scavenger and reacting with TiO(2) to form peroxo-compounds, contributing to the inhibition of the reaction. The use of the response surface methodology allowed to fit the optimal values of the parameters pH and catalyst concentration leading to the total solar degradation of orange II. The optimal pH range was 4.5-5.5 close to the zero point charge of TiO(2) depending on surface charge of catalyst and dye ionization state. Dosage of catalyst higher than 1.1 gl(-1) decreases the degradation efficiency due to a decrease of light penetration.  相似文献   

3.
Kinetics and mechanism of TNT degradation in TiO2 photocatalysis   总被引:9,自引:0,他引:9  
Son HS  Lee SJ  Cho IH  Zoh KD 《Chemosphere》2004,57(4):309-317
The photocatalytic degradation of TNT in a circular photocatalytic reactor, using a UV lamp as a light source and TiO(2) as a photocatalyst, was investigated. The effects of various parameters such as the initial TNT concentration, and the initial pH on the TNT degradation rate of TiO(2) photocatalysis were examined. In the presence of both UV light illumination and TiO(2) catalyst, TNT was more effectively degraded than with either UV or TiO(2) alone. The reaction rate was found to obey pseudo first-order kinetics represented by the Langmuir-Hinshelwood model. In the mineralization study, TNT (30 mg/l) photocatalytic degradation resulted in an approximately 80% TOC decrease after 150 min, and 10% of acetate and 57% of formate were produced as the organic intermediates, and were further degraded. NO(-)(3) NO(-)(2), and NH(+)(4) were detected as the nitrogen byproducts from photocatalysis and photolysis, and more than 50% of the total nitrogen was converted mainly to NO(-)(3)in the photocatalysis. However, NO(-)(3) did not adsorbed on the TiO(2) surface. TNT showed higher photocatalytic degradation efficiency at neutral and basic pH.  相似文献   

4.
Ryu CS  Kim MS  Kim BW 《Chemosphere》2003,53(7):765-771
Alachlor photodegradation was performed using TiO(2), which was synthesized by a modified sol-gel method. The thickness of a TiO(2) film immobilised by a 5-time dip-coating was 174 nm and the average diameter of TiO(2) particles was about 10-15 nm in SEM images. The crystal structure of a TiO(2) film calcinated at 300 degrees C for 1 h was observed as a typical anatase type. The stability of a TiO(2) film by a modified sol-gel method was 4% better than TiO(2) by a typical sol-gel method.The removal rate of alachlor with both Fe(3+) and UV radiation in the absence of TiO(2) was 0.28 mg/l/h in 10 h and the removal rate of alachlor with Fe(3+)/UV in the presence of TiO(2) was 0.32 g/l/h, which was higher by 14% than that with Fe(3+)/UV system. TOC concentration during the alachlor degradation with both TiO(2) and UV radiation in the absence of added Fe(3+) decreased from 100%, through 81% and 51%, to 44% with time elapses of 4, 8, and 10 h, respectively, while TOC concentration with both added Fe(3+) and UV radiation in the absence of TiO(2) decreased from 100% to 70% in 10 h.  相似文献   

5.
以陶瓷为载体,采用溶胶-凝胶法制备了银离子和铈离子共掺杂TiO2的负载型光催化剂——T-AC/陶瓷,研究了pH值、双氧水用量、催化剂用量、紫外灯强度、废水的初始浓度等因素对T-AC/陶瓷光催化剂降解甲基橙染料废水的影响。结果表明,当pH为2、双氧水用量为0.5 mL/100 mL、催化剂用量为3 g/L、紫外灯功率为20 W、废水初始浓度为10mg/L时,甲基橙的降解率可达85.9%,并且甲基橙的光催化降解属于一级动力学方程,T-AC/陶瓷催化剂有较高的活性和稳定性,在废水处理中具有较好的应用前景。  相似文献   

6.
In this study, advanced oxidation process utilizing Fenton's reaction was investigated for the decolorization and degradation of two commercial dyes viz., Red M5B, Blue MR and H-acid, a dye intermediate used in chemical industries for the synthesis of direct, reactive and azo dyes. Effect of Fe2 +, H2O2, pH, and contact time on the degradation of the dyes was studied. Maximum color and COD removal was obtained for Red MSB, H-acid and Blue MR at 10-25 mg/l of Fe2+ dose and 400-500 mg/l of H2O2 dose at pH 3.0. The initial oxidation reaction was found to fit into first order rate kinetics and the rate of oxidation of H-acid was higher than the other dyes. Release of chloride and sulfate from the Fenton's treated Red M5B dye and sulfate from H-acid and Blue MR indicates that the dye degradation proceeds through cleavage of the substituent group.  相似文献   

7.
Photo-oxidation of cork manufacturing wastewater   总被引:7,自引:0,他引:7  
Several photo-activated processes have been investigated for oxidation of a cork manufacturing wastewater. A comparative activity study is made between different homogeneous (H2O2/UV-Vis and H2O2/Fe2+/UV-Vis) and heterogeneous (TiO2/UV-Vis and TiO2/H2O2/UV-Vis) systems, with degradation performances being evaluated in terms of total organic carbon (TOC) removal. Results obtained in a batch photo-reactor show that photo-catalysis with TiO2 is not suitable for this kind of wastewater while the H2O2/UV-Vis oxidation process, for which the effect of some operating conditions was investigated, allows to remove 39% of TOC after 4 h of operation (for C(H2O2)=0.59 M, pH=10 and T=35 degrees C). The combined photo-activated process, i.e., using both TiO2 and H2O2, yields an overall TOC decrease of 46% (for C(TiO2)=1.0 gl(-1)). The photo-Fenton process proved to be the most efficient, proceeds at a much higher oxidation rate and allows to achieve 66% mineralization in just 10 min of reaction time (for C(H2O2)=0.31 M, T=30 degrees C, Fe2+:H2O2=0.12 (mol) and pH=3.2).  相似文献   

8.
超声-Fenton法处理偶氮染料橙黄II的研究   总被引:1,自引:0,他引:1  
以偶氮染料橙黄II为研究对象 ,考察了Fenton反应在超声辐射条件下 ,pH值、H2 O2 浓度、Fe2 + 离子浓度对COD去除率的影响。实验结果表明 ,超声对Fenton试剂处理偶氮染料橙黄II具有强化作用。超声条件下 ,当染料浓度为10 0mg/L、pH为 3.0、Fe2 + 离子浓度为 10mg/L、H2 O2 浓度为 4 0 0mg/L时 ,反应 90min ,COD去除率最高可达 93%。  相似文献   

9.
采用水热晶化法合成了不同含铜量的Cu—SBA-15介孔分子筛,并且用XRD、N2吸附、TEM以及uV—vis对所合成的样品进行表征。以Cu—SBA-15为催化剂,H2O2为氧化剂,催化湿式过氧化水溶液中的罗丹明B,主要考察H2O2浓度、催化剂用量、处理温度、初始pH等因素对罗丹明B氧化效果的影响。结果表明,在同样的处理条件下罗丹明的脱色率明显高于TOC去除率,处理温度、初始pH对罗丹明B的脱色与氧化有重要影响。在罗丹明B初始浓度100mg/L,H2O2初始浓度1.8g/L,催化剂量0.3g/L,温度60℃,pH为7.0,处理时间100min时,罗丹明B的脱色率为98.6%,TOC去除率为62.8%。  相似文献   

10.
利用水热合成法制备了Keggin结构的Fe-Mo-Zr杂多酸盐光催化剂,并利用红外光谱(IR)对催化剂进行了表征。实验以酸性大红(GR)为模拟污染物,考察了在紫外灯照射下,Fe-Mo-Zr杂多酸盐的投加量、污染物的浓度和pH值以及外加H2O2对光催化降解效果的影响。实验结果表明,当催化剂的投加量为0.6 g/L,pH为5~7,初始浓度为10 mg/L的GR染料溶液,光照160 min,脱色率可达87.98%。外加H2O2可以提高光催化反应效率。  相似文献   

11.
不同高级氧化法对水中低浓度药物甲硝唑降解过程的比较   总被引:3,自引:0,他引:3  
采用UV、H2O2、UV/H2O2、Fenton、UV/Fenton和UV/TiO2方法,对水中低浓度的药物甲硝唑进行降解。通过HPLC和UV-Vis光谱得到的甲硝唑去除率。详细讨论了Fe2+、TiO2和H2O2的初始浓度以及溶液的初始pH值对降解效率的影响。结果表明,UV/Fenton和UV/TiO2 2种系统对水中低浓度甲硝唑均有很好的去除效果,但前者的光催化效率更高。在甲硝唑浓度=6 μmol/L,H2O2和Fe2+的初始浓度分别为0.5 mg/L和2.94 μmol/L,pH=4的条件下,UV/Fenton方法对甲硝唑水溶液光催化的最佳效率为95.8%。  相似文献   

12.
采用负载纳米TiO2的三维镍网装配了光催化反应器,就其对酸性品红溶液进行脱色效果进行了实验研究。考察了反应器的3种装配条件、品红初始浓度、pH值、H2O2投加量、紫外光剂量等因素对酸性品红脱色效果的影响。结果表明:UV灯+镍网+TiO2模式组合的反应器脱色效果最好;在相同的处理时间内酸性品红溶液的脱色率随起始浓度的增大而减小;将酸性品红溶液pH值调至5时脱色效果最明显,70 min的脱色率可高达94.8%。脱色效果还可以通过溶液中添加H2O2和控制紫外线剂量来调节。当溶液中H2O2投加量为0.5 g/L时,处理70 min后的脱色率可高达98.3%;到达反应界面紫外光剂量越多则能够获得越高的酸性品红脱色率。  相似文献   

13.
In this study, advanced oxidation technologies, namely Fenton Process (FP), Fenton-Like Process (FLP), ozonation (O3) and O3/H2O2 processes, were applied to synthetic wastewater containing 3-indolebutyric acid (IBA). The effectiveness of each process was investigated at different pH values, Fe(+2), Fe(+3), O3 and H2O2 concentrations with respect to the removal efficiencies for chemical oxygen demand (COD) and total organic carbon (TOC). The best removal efficiencies were seen at pH 3 and 2 mM Fe concentration in both FP and FLP, in which the optimum H2O2 concentrations were 6 mM for FP and 10 mM for FLP. Optimum process conditions were pH 12 for the O3 process, pH 9 for the O3/H2O2 process and 1:1 O3/H2O2 molar ratio. The highest COD removal efficiency was 86 percent, obtained in the O3/H2O2 process and the highest TOC removal efficiency was obtained at 77 percent in the FP.  相似文献   

14.
环境中抗生素的出现及其引起的危害正受到越来越多的关注。以高压汞灯为光源,选用较为广泛的抗生素土霉素(OTC)为处理对象。考察了初始质量浓度、反应过程中光照、催化剂投加量、溶液起始pH、溶液中DOM和NO-3对光催化降解的影响,研究了其光降解动力学。结果表明,TiO2光催化氧化法能够有效去除水中半微量的OTC,OTC的光降解过程符合一级反应动力学模型;UV/TiO2联用工艺对TOC也有很好的去除效果,反应90 min,TOC去除率可达74%;OTC的初始浓度从30 mg/L增大到90 mg/L,反应速率从0.0619 min-1降低到0.0130 min-1;随着光催化剂投加量的增大,光降解速率常数先增大后减小;增加溶液的pH值,速率常数逐渐减小;溶液中的DOM和NO-3也可以影响光降解效率。  相似文献   

15.
Concentration of 2,4-dichlorophenoxyacetic acid (2,4-D) may affect its degradation kinetics in advanced oxidation systems, and combinations of two or more systems can be more effective for its mineralization at low concentration levels. Degradations and mineralizations of 0.045mM 2,4-D using O(3), O(3)/UV, UV/TiO(2) and O(3)/UV/TiO(2) systems were compared, and influence of reaction temperature on the mineralization in O(3)/UV/TiO(2) system was investigated. 2,4-D degradations by O(3), O(3)/UV and UV/TiO(2) systems were similar to the results of earlier investigations with higher 2,4-D concentrations. The degradations and total organic carbon (TOC) removals in the four systems were well described by the first-order reaction kinetics. The degradation and removal were greatly enhanced in O(3)/UV/TiO(2) system, and further enhancements were observed with larger O(3) supplies. The enhancements were attributed to hydroxyl radical (()OH) generation from more than one reaction pathway. The degradation and removal in O(3)/UV/TiO(2) system were very efficient with reaction temperature fixed at 20 degrees C. It was suspected that reaction temperature might have influenced ()OH generation in the system, which needs further attention.  相似文献   

16.
The photodegradation of monuron (3-(4-chlorophenyl)-1,1-dimethylurea) in aqueous solutions under simulated solar irradiation has been conducted by different advanced oxidation processes (UV/H(2)O(2), UV/H(2)O(2)/Fe(2+), UV/H(2)O(2)/TiO(2), UV/TiO(2), dark H(2)O(2)/Fe(3+)). The degradation rates were always higher for the homogeneous catalysis in photo-Fenton reactions (UV/H(2)O(2)/Fe(2+)) compared to the heterogeneous photocatalytic systems (TiO(2)/UV and UV/H(2)O(2)/TiO(2)). Optimal concentrations of Fe(2+) and H(2)O(2) for the abatement of the herbicide in the photo-Fenton system were found to be 1 mM Fe(II) and 10 mM H(2)O(2). Several intermediary products were identified using large volume injection micro-liquid chromatography with UV detection (mu-LC-UV), mu-LC-MS and GC-MS techniques and a degradation mechanism has been proposed.  相似文献   

17.
TiO2/Ti转盘液膜反应器光电催化处理罗丹明B   总被引:2,自引:0,他引:2  
采用溶胶-凝胶法制备了TiO2/Ti电极,X射线衍射(XRD)分析表明,TiO2主要为锐钛矿,晶粒尺寸约为46 nm.以TiO2/Ti电极作阳极,Cu电极作阴极,组装成转盘液膜反应器,考察了其光电催化处理染料罗丹明B(RhB)的影响因素(转盘转速、偏压、溶液初始pH、RhB初始浓度和电解质浓度).得到最佳处理条件为:转盘转速90 r/min,偏压0.4V,溶液初始pH2.5,电解质(硫酸钠)质量浓度0.5 g/L.在最佳处理条件下,处理20 mg/L RhB染料废水90 min的脱色率和总有机碳(TOC)去除率分别达到97.2%和72.7%.结果表明,由于同时强化了激发光源的利用率和溶液的传质效率,TiO2/Ti转盘液膜反应器可高效光电催化处理染料废水.  相似文献   

18.
Ling CM  Mohamed AR  Bhatia S 《Chemosphere》2004,57(7):547-554
TiO2 thin film photocatalyst was successfully synthesized and immobilized on glass reactor tube using sol-gel method. The synthesized TiO2 coating was transparent, which enabled the penetration of ultra-violet (UV) light to the catalyst surface. Two photocatalytic reactors with different operating modes were tested: (a) tubular photocatalytic reactor with re-circulation mode and (b) batch photocatalytic reactor. A new proposed TiO2 synthesized film formulation of 1 titanium isopropoxide: 8 isopropanol: 3 acetyl acetone: 1.1 H2O: 0.05 acetic acid (in molar ratio) gave excellent photocatalytic activity for degradation of phenol and methylene blue dye present in the water. The half-life time, t1/2 of photocatalytic degradation of phenol was 56 min at the initial phenol concentration of 1000 microM in the batch reactor. In the tubular photocatalytic reactor, 5 re-circulation passes with residence time of 2.2 min (single pass) degraded 50% of 40-microM methylene blue dye. Initial phenol concentration, presence of hydrogen peroxide, presence of air bubbling and stirring speed as the process variables were studied in the batch reactor. Initial methylene blue concentration, pH value, light intensity and reaction temperature were studied as the process variables in the tubular reactor. The synthesized TiO2 thin film was characterized using SEM, XRD and EDX analysis. A comparative performance between the synthesized TiO2 thin film and commercial TiO2 particles (99% anatase) was evaluated under the same experimental conditions. The TiO2 film was equally active as the TiO2 powder catalyst.  相似文献   

19.
以水体异味物质2-甲基异莰醇(2-methylisoborneol,2-MIB)为研究对象,在紫外光(λ<380 nm)照射下,探讨TiO2(P25)对2-MIB的光催化降解特性及光化学作用机理。结果表明,UV/TiO2光催化体系可以有效去除水体异味物质2-MIB,紫外光照射60 min,对2-MIB的降解率达95%。同时研究了光催化降解体系介质pH,共存腐殖酸(HA)和过硫酸钾(K2S2O8)对UV/TiO2光催化体系降解2-MIB的影响,发现低浓度HA([HA]≤0.5 mg/L)可以提高2-MIB降解速率,当HA浓度高于0.5 mg/L,2-MIB降解反应受到抑制;同时当加入电子受体K2S2O8后,降解体系中活性物种羟基自由基(.OH)明显增加,提高了TiO2对2-MIB的降解能力。利用苯甲酸荧光光度法和POD-DPD显色法跟踪测定降解过程中羟基自由基(·OH)和过氧化氢(H2O2)的变化,表明光催化反应涉及·OH机理。  相似文献   

20.
Liao CH  Lu MC  Su SH 《Chemosphere》2001,44(5):913-919
The purpose of this study is to reveal the role of cupric ions as a natural water contaminant in the H2O2/UV oxidation of humic acids. Humic acids are naturally occurring organic matter and exhibit a strong tendency of complexation with some transition metal ions. Chlorination of humic acids causes potential health hazards due to formation of trihalomethane (THM). The removal of THM precursors has become an issue of public concern. The H2O2/UV process is capable of mineralizing humic acids due to formation of a strong oxidant, hydroxyl radicals, in reaction solution. Experiments were conducted in a re-circulated photoreactor. Different cupric concentrations (0-3.8 mg/l) and different pH values (4-9) were controlled to determine their effects on the degradation of humic acids, UV light absorbance at 254 nm, and H2O2. The presence of cupric ions inhibits humic mineralization and decreases the rate of destruction of humic acids which absorb UV light at 254 nm. On the other hand, the higher the cupric concentration, the lower the H2O2 decomposition rate. In the studied pH range, the minimum of total organic carbon (TOC) removal occurs at pH = 6 in the presence of 2.6 mg/l of cupric ions; both acidification (pH = 4) and alkaline condition (pH = 9) lead to a better removal of TOC. It is inferred from this study that the cupric-complexed form of humic acids is more refractory than the non-complexed one.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号