共查询到20条相似文献,搜索用时 46 毫秒
1.
2.
3.
4.
CuO/γ-Al_2O_3负载型催化剂催化燃烧处理油烟 总被引:1,自引:1,他引:0
采用等体积漫渍法制备不同CuO负载量的CuO/γ-Al2O3负载型催化剂,用X射线衍射仪、扫描电镜对该催化剂负载层活性组分的表面形态、晶相结构和颗粒大小进行表征,考察了该催化荆催化燃烧处理油烟的催化活性(以油烟净化效率表征).结果显示,催化活性随CuO负载量的增加.反应温度的升高而提高,但随烟气流量的增大而降低;在CuO负载量为20%(质量分数)、反应温度为350℃.烟气流量为5 L/min的最佳实验条件下,CuO/γ-Al2O3负载型催化剂的油烟净化效率最高.可达88.6%.该催化剂对油烟的催化燃烧具有较高的催化活性. 相似文献
5.
6.
7.
8.
富氧条件下选择性还原NO的复合催化剂体系 总被引:2,自引:0,他引:2
选择性催化还原法是净化稀燃汽车尾气中NOx的最有效途径之一,单一催化组分或单一类型的催化剂很难满足实际需要,复合催化剂的研究成为必然趋势。本文介绍了复合催化体系的组合形式,回顾了国内外最近几年复合催化剂体系净化NOx的研究成果,为将来设计新的复合催化体系提出了建议。 相似文献
9.
低浓度硫化氢废气的液相催化氧化法净化实验研究 总被引:8,自引:0,他引:8
针对H2S浓度为750~1500 mg/m^3的气体的液相催化氧化技术进行了动力学实验研究.配制了以铁基离子作为主催化剂的复合吸收净化溶液,同时加入稳定剂和表面活性剂提高催化剂在碱性吸收溶液的活性.分别考察了原料气中H2S、O2含量以及吸收液中催化剂离子浓度、温度等因素对吸收速率的影响;确定了较为理想的吸收操作条件并获得了较好的吸收净化效果;饱和吸收液易于再生,净化性能恢复良好,可重复使用. 相似文献
10.
11.
12.
The photolysis of fenitrothion in vapor and liquid phase has been examined, using radiation available in the solar spectrum, i.e., λ> 300 nm. In both the vapor phase and in ethanol solution, two primary products are produced, the major one being p-nitrocresol (4-nitro-3-methyl-phenol). Prolonged irradiation yields additional products probably due to secondary photolysis. The photodecomposition of fenitrothion may be one of the reasons for the rapid disappearance of this material when it is introduced into the environment. 相似文献
13.
Rhodobacter sp. NP25b菌株缺氧降解壬基酚聚氧乙烯醚的研究 总被引:1,自引:0,他引:1
从城市污水处理厂活性污泥中分离得到一株能够在缺氧条件下以壬基酚聚氧乙烯醚(NPEOs)为惟一碳源和能源生长的菌株NP25b.经生理生化鉴定和16S rRNA基因序列分析,该菌株属于红细菌属(Rhodobacter sp.),对该菌株降解NPEOs的特性进行了研究.结果表明,在缺氧条件下,菌株NP25b在7 d内对初始底物浓度为400 mg/L NPEOs的降解率可达84%.利用液相色谱-质谱(LC-MS)和气相色谱-质谱(GC-MS)对NPEOs降解中间产物进行了分析,结果表明,主要降解产物为短链NPEOs和壬基酚聚氧乙烯醚乙酸(NPECs),其中包括具有较强内分泌干扰效应的NP1EO.该菌株能够代谢含有疏水基团的聚氧乙烯醚类表面活性剂,例如辛基酚聚氧乙烯醚和脂肪醇聚氧乙烯醚.推测菌株NP25b降解NPEOs是通过乙氧基(EO)链末端氧化后逐步切割完成的. 相似文献
14.
15.
Effect of Fe0 quantity on the efficiency of integrated microbial-Fe0 treatment processes 总被引:4,自引:0,他引:4
Batch experiments were conducted with different reaction systems to investigate how the treatment efficiency of integrated microbial-Fe0 processes is affected by the amount of Fe0 added. Abiotic experiments with hexavalent chromium and carbon tetrachloride mixtures corroborated that different pollutants could compete for reactive sites on the iron surface, which would hinder specific degradation rates when the available Fe0 surface area is relatively small (e.g., 11 m(2) l(-1)). In such cases, reductive precipitation of chromium could occlude reactive sites and significantly inhibit removal efficiency. Microbial participation in the cleanup process was also influenced by the amount of Fe0 added. Increasing the Fe0 dose (and thus the available surface area) had a stimulatory effect possibly due to a higher production of cathodic H2, which can be used as electron donor for reductive biotransformation of many pollutants. However, high Fe0 doses had an inhibitory effect due to a corrosion-induced increase in pH beyond the optimum range of the bacteria. This suggest that there may be a system-specific, optimum quantity of Fe0 that satisfies availability requirements to preclude contaminant competition for reactive sites and biological requirements for H2 production while minimizing inhibitory increases in pH. Results also confirmed extensive RDX mineralization in bioaugmented (but not in abiotic) Fe0 systems, and support the notion that permeable reactive iron barriers performance might be enhanced by the participation of some microorganisms. 相似文献
16.
Thiagarajan Vignesh Ramasubbu Seenivasan Natarajan Chandrasekaran Mukherjee Amitava 《Environmental science and pollution research international》2019,26(21):21394-21403
Environmental Science and Pollution Research - The use of P25 TiO2 NPs in consumer products, their release, and environmental accumulation will have harmful effects on the coastal ecosystems. The... 相似文献
17.
Jia H Gu C Li H Fan X Li S Wang C 《Environmental science and pollution research international》2012,19(8):3498-3505
Zero-valent iron holds great promise in treating groundwater, and its reactivity and efficacy depend on many surrounding factors. In the present work, the effects of solution chemistry such as pH, humic acid (HA), and inorganic ions on pentachlorophenol (PCP) dechlorination by smectite-templated Pd(0)/Fe(0) were systematically studied. Smectite-templated Pd(0)/Fe(0) was prepared by saturating the negatively charged sites of smectite clay with Fe(III) and a small amount of Pd(II), followed by borohydride reduction to convert Fe(III) and Pd(II) into zero-valent metal clusters. Batch experiments were conducted to investigate the effects of water chemistry on PCP remediation. The PCP dechlorination rate critically depends on the reaction pH over the range 6.0~10.0; the rate constant (k (obs)) increases with decreasing the reaction pH value. Also, the PCP remediation is inhibited by HA, which can be attributed to the electron competition of HA with H(+). In addition, the reduction of PCP can be accelerated by various anions, following the order: Cl(-) > HCO (3) (-) > SO (4) (2-) ~no anion. In the case of cations, Ca(2+) and Mg(2+) (10 mM) decrease the dechlorination rate to 0.7959 and 0.7798 from 1.315 h(-1), respectively. After introducing HA into the reaction systems with cations or/and anions, the dechlorination rates are similar to that containing HA alone. This study reveals that low pH and the presence of some anions such as Cl(-) facilitate the PCP dechlorination and induce the rapid consumption of nanosized zero-valent iron simultaneously. However, the dechlorination rate is no longer correlated to the inhibitory or accelerating effects by cations and anions in the presence of 10 mg/L HA. 相似文献
18.
Candis S. Claiborn Dennis Finn Timothy V. Larson Jane Q. Koenig 《Journal of the Air & Waste Management Association (1995)》2013,63(8):1440-1445
ABSTRACT The revised National Ambient Air Quality Standards for PM include fine particulate standards based upon mass measurements of PM25. It is possible in arid and semi-arid regions to observe significant coarse mode intrusion in the PM2.5 measurement. In this work, continuous PM10, PM2.5, and PM1.0 were measured during several windblown dust events in Spokane, WA. PM2 5 constituted ~30% of the PM10 during the dust event days, compared with ~48% on the non-dusty days preceding the dust events. Both PM10 and PM2.5 were enhanced during the dust events. However, PM1.0 was not enhanced during dust storms that originated within the state of Washington. During a dust storm that originated in Asia and impacted Spokane, PM1.0 was also enhanced, although the Asian dust reached Washington during a period of stagnation and poor dispersion, so that local sources were also contributing to high particulate levels. The “intermodal” region of PM, defined as particles ranging in aerodynamic size from 1.0 to 2.5 um, was found to represent a significant fraction of PM25 (~51%) during windblown dust events, compared with 28% during the non-dusty days before the dust events. 相似文献
19.
R. K. M. Jayanty J. A. Sokash G. B. Howe R. G. Fuerst T. J. Logan M. R. Midgett 《Journal of the Air & Waste Management Association (1995)》2013,63(12):1342-1346
A simple, inexpensive, and accurate technique for evaluating or auditing the sampling, recovery, and analytical phases of EPA Source Reference Method 25 has been developed. The technique involves spiking a U-shaped stainless steel cartridge containing Tenax® with known quantities of selected organic compounds and thermally desorbing them at temperatures from 160°C to 180°C to generate organic vapors quantitatively. The major advantages of this technique are that no other measurement methods can be used to determine the generated organic concentrations in lieu of Method 25; and that the cartridge can easily be taken to the field for evaluation. The organic compounds generated in test runs are collected and analyzed using the Method 25 procedure. The generation of organics is quantitative and recoveries were found to be 100 ± 10%. The time required for desorption of the majority of organics is generally less than forty-five minutes at a flow rate of 100 mL/min; however, based on laboratory experience the recommended sampling time is sixty minutes. These spiked cartridges are stable at room temperature over a two-month period. Results of interlaboratory studies showed close agreement with the expected concentrations based on calculations from the mass loadings and sample volumes. 相似文献