首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective of this study was to develop a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of Ochratoxin A (OTA) and Ochratoxin α (OTα) in poultry tissues and eggs. The two toxins were extracted by a mixture of acetonitrile/water, purified with a reversed phase C18 solid phase extraction column (SPE) and determined by LC-MS/MS. The LC-MS/MS method performances were evaluated in terms of linearity in solvent and in matrix (ranged from 0.5 to 15.10 µg L?1 for OTA and from 0.60 to 17.85 µg L?1 for OTα), limit of detection (LOD), limit of quantitation (LOQ), specificity, accuracy and precision in repeatability conditions. Recovery experiments were performed by spiking poultry liver, kidney, muscle and eggs around 1 µg kg?1 and 10 µg kg?1. LODs were 0.27 and 0.26 µg kg?1 while LOQs were fixed at 1.0 and 1.2 µg kg?1 for OTA and OTα, respectively. Main recoveries for OTA ranged from 82 to 109% and for OTα ranged from 55 to 89%. The values of within-laboratory relative standard deviation (RSDr) were equal to or below 20%. Considering the results obtained and that all analytical performance criteria were fulfilled, the new extraction and purification method developed for OTA and OTα determination in animal tissues and eggs was found appropriate for control laboratories and research activities designed to ensure food safety.  相似文献   

2.
In this study, a two-dimensional liquid chromatography tandem mass spectrometry method was developed and validated for the determination of pesticide residues and contaminants in whole wheat grains and oats. The samples were extracted with a mixture of acetonitrile and water and were injected into the two-dimensional LC-MS/MS system without any further clean-up or sample preparation. Samples were analyzed with four different matrix matched calibrations. Matrix effects were evaluated by comparing analyte signals in the respective matrix matched standard with the neat solvent standards. The final method was validated according to the current Eurachem validation guide and SANTE document. The number of successfully validated analytes throughout all three validation levels in oats and wheat, respectively, were as follows: 330 and 316 out of 370 pesticides, 6 and 13 out of 18 pyrrolizidine alkaloids and 7 out of 9 regulated mycotoxins. Moreover, both plant growth regulators mepiquat and chlormequat as well as the tropane alkaloids atropine and scopolamine met the validation criteria. The majority of pesticides showed limits of detection below 1?µg kg?1, pyrrolizidine alkaloids below 0.7?µg kg?1, tropane alkaloids below 0.2?µg kg?1, growth regulators below 0.7?µg kg?1 and mycotoxins below 8?µg kg?1 in both matrices.  相似文献   

3.
A method for the identification and quantification of pesticide residues in water, soil, and sediment samples has been developed, validated, and applied for the analysis of real samples. The specificity was determined by the retention time and the confirmation and quantification of analyte ions. Linearity was demonstrated over the concentration range of 20 to 120 µg L?1, and the correlation coefficients varied between 0.979 and 0.996, depending on the analytes. The recovery rates for all analytes in the studied matrix were between 86% and 112%. The intermediate precision and repeatability were determined at three concentration levels (40, 80, and 120 µg L?1), with the relative standard deviation for the intermediate precision between 1% and 5.3% and the repeatability varying between 2% and 13.4% for individual analytes. The limits of detection and quantification for fipronil, fipronil sulfide, fipronil-sulfone, and fipronil-desulfinyl were 6.2, 3.0, 6.6, and 4.0 ng L?1 and 20.4, 9.0, 21.6, and 13.0 ng L?1, respectively. The method developed was used in water, soil, and sediment samples containing 2.1 mg L?1 and 1.2% and 5.3% of carbon, respectively. The recovery of pesticides in the environmental matrices varied from 88.26 to 109.63% for the lowest fortification level (40 and 100 µg kg?1), from 91.17 to 110.18% for the intermediate level (80 and 200 µg kg?1), and from 89.09 to 109.82% for the highest fortification level (120 and 300 µg kg?1). The relative standard deviation for the recovery of pesticides was under 15%.  相似文献   

4.
Parabens have been widely used as antimicrobial agents, mainly in food products, pharmaceuticals, and cosmetics. Although they are known as safe preservatives, they also cause some harm to human health, which has been discussed lately. Therefore, the aim of this study was to evaluate the occurrence of nine parabens (including isomers) in mineral and drinking waters, besides in drinking water treatment sludge (DWTS) samples with determination by liquid chromatography tandem mass spectrometry (LC-MS/MS). Both methods solid phase extraction (SPE) and QuEChERS were validated. Calibration curves showed a correlation coefficient of 0.99 for all compounds. LOQ values ranged from 0.04 to 4 μg L?1 in aqueous matrices and from 5 to 500 ng g?1 in DWTS. Recoveries between 70 and 115% were reached with RSD below 20% for all compounds in SPE whereas recoveries between 62 and 119% were found with RSD below 20% for almost all compounds in QuEChERS. Matrix effect had low values (<?20%); it was only above 20% for methylparaben in the SPE and for pentylparaben in the QuEChERS. Using a quick and simple extraction procedures with SPE, QuEChERS, and LC-MS/MS analyses, these methods proved to be selective and sensitive. They were successfully applied to real samples (treated water, mineral water, and sludge), and methylparaben was detected at concentration levels below 0.242 μg L?1 in mineral and treated water samples and 10 ng g?1 in DWTS samples.  相似文献   

5.
We investigated the occurrence of three pharmaceutical residues in four wastewater treatment plants (WWTPs) from northern Tunisia. The selected compounds were carbamazepine, naproxen, and ibuprofen; they are among the most commonly prescribed and widely used pharmaceutical agents worldwide. Samples (200?mL) were pre-concentrated using the solid phase extraction (SPE) enrichment procedure and the analysis of the pharmaceuticals was performed with high-performance liquid chromatography (HPLC-UV). The overall procedure provided limits of detection (LOD) lower than 0.5 µg.L?1and recoveries of 78–97%. For the carbamazepine compound, the mean concentrations were 60.58, 93.19, and 132 µg.L?1 for the Bizerte, Jendouba, and Tunis WWTPs, respectively. This pharmaceutical was not detected in the Beja WWTPs. Naproxen and ibuprofens were not detected in the Jendouba WWTP but were found in the three other WWTPs with concentrations ranging from 2.94 to 36.17 µg.L?1 and from 8.02 to 43.22 µg.L?1, respectively. From the obtained data, it seems that these WWTPs are not able to eliminate this kind of micro-pollutants.  相似文献   

6.
The residual levels of antibiotics in Vietnamese eggs were monitored from 2014 to 2015. A total of 111 egg packages, distributed by 11 different companies, were collected from supermarkets in Ho Chi Minh City and the levels of 28 antibiotics were analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) screening method. Sixteen samples tested positive for antibiotics; a total of eight compounds (enrofloxacin, ciprofloxacin, norfloxacin, sulfadimethoxine, sulfamethazine, sulfamonomethoxine, tilmicosin and trimethoprim) were detected. Enrofloxacin was detected in eight samples, with two samples exhibiting concentrations exceeding 1,000 µg kg?1. Tilmicosin was detected in three samples at a range of 49–568 µg kg?1. We observed that two of the 11 companies frequently sold antibiotic-contaminated eggs (detection rates of 56 and 60%), suggesting that a number of companies do not regulate the use of antibiotics in egg-laying hens. Our findings indicate that livestock farmers require instruction regarding antibiotic use and that continual antibiotic monitoring is essential in Vietnam.  相似文献   

7.
The goals of this study were to determine the levels of three antibiotics – enrofloxacin, flumequine and sulfamethoxazole – in Pangasius catfish products imported into Thailand and to assess the health risks from consumption. To extract these antibiotic residues, acetonitrile, methanol and a small amount of formic acid were used as solvents. Determination of the antibiotics after extraction steps was carried out by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) technique. The results showed that 14 and 3 samples of Pangasius catfish products were contaminated with enrofloxacin and sulfamethoxazole, respectively. No flumequine residue was found. While the concentration levels of these antibiotics in most contaminated samples were lower than the European Union (EU) standard, one sample was found to contain sulfamethoxazole at 245.91 µg kg?1, which was higher than the EU standard (100 µg kg?1), indicating the likelihood that some contaminated freshwater fish products are widely distributed in Thai markets. Notably, the concentration levels of enrofloxacin in samples of Pangasius catfish with skin were higher than in non-skin products, suggesting that products with skin might retain more antibiotic residues than non-skin products. Although the hazard quotient showed that consuming imported Pangasius catfish products, based on the current consumption rate, will not adversely affect consumer health, antibiotic residues in Pangasius catfish products imported into Thailand should be continually monitored.  相似文献   

8.
Organochlorine pesticides present in sewage sludge can contaminate soil and water when they are used as either fertilizer or agricultural soil conditioner. In this study, the technique solid–liquid extraction with low temperature purification was optimized and validated for determination of ten organochlorine pesticides in sewage sludge and soil samples. Liquid–liquid extraction with low temperature purification was also validated for the same compounds in water. Analyses were performed by gas chromatography-mass spectrometry operating in the selective ion monitoring mode. After optimization, the methods showed recoveries between 70% and 115% with relative standard deviation lower than 13% for all target analytes in the three matrices. The linearity was demonstrated in the range of 20 to 70 µg L?1, 0.5 to 60 µg L?1, and 3 to 13 µg L?1, for sludge, soil, and acetonitrile, respectively. The limit of quantification ranged between 2 and 40 µg kg?1, 1 and 6 µg kg?1, and 0.5 µg L?1 for sludge, soil, and water, respectively. The methods were used in the study of pesticide lixiviation carried out in a poly vinyl chlorine column filled with soil, which had its surface layer mixed with sludge. The results showed that pesticides are not leached into soil, part of them is adsorbed by the sewage sludge (4–40%), and most pesticides are lost by volatilization.  相似文献   

9.
A method combining ultrasound-assisted emulsification–microextraction (USAEME) with gas chromatography–mass spectrometry (GC–MS) was developed for simultaneous determination of four acidic pharmaceuticals, ibuprofen, naproxen, ketoprofen, and diclofenac, as well as four phenols, 4-octylphenol, 4-n-nonylphenol, bisphenol A, and triclosan in municipal wastewaters. Conditions of extraction and simultaneous derivatization were optimized with respect to such aspects as type and volume of extraction solvent, volume of derivatization reagent, kind and amount of buffering salt, location of the test tube in the ultrasonic bath, and extraction time. The average correlation coefficient of the calibration curves was 0.9946. The LOD/(LOQ) values in influent and effluent wastewater were in the range of 0.002–0.121/(0.005–0.403) μg L?1 and 0.002–0.828/(0.006–2.758) μg L?1, respectively. Quantitative recoveries (≥94 %) and satisfactory precision (average RSD 8.2 %) were obtained. The optimized USAEME/GC–MS method was applied for determination of the considered pharmaceuticals and phenols in influents and treated effluents from nine Polish municipal wastewater treatment plants. The average concentration of acidic pharmaceuticals in influent and effluent wastewater were in the range of 0.06–551.96 μg L?1 and 0.01–22.61 μg L?1, respectively, while for phenols were in the range of 0.03–102.54 μg L?1 and 0.02–10.84 μg L?1, respectively. The removal efficiencies of the target compounds during purification process were between 84 and 99 %.  相似文献   

10.
Abstract

Glyphosate is the main herbicide currently used in the world due to wide applicability and efficiency in controlling weeds in many crops. However, its overuse may lead to undesirable impacts on the environment and to human health in the long run. This present study aimed to optimize and validate solid phase extraction (SPE) using an anionic resin for the simultaneous and direct determination of glyphosate and aminomethylphosphonic acid (AMPA) in water samples using high-performance liquid chromatography combined with inductively coupled plasma with triple quadrupole mass spectrometer (HPLC-ICP-MS/MS). The results showed that recovery percentage and relative standard deviation were 103.9?±?7.9 and 99.40?±?9.9% for glyphosate and AMPA, respectively. The validation certified that the method was precise, accurate, linear, and selective, with a limit of quantification of 1.09 and 0.29?μg L?1 for glyphosate and AMPA, respectively. The optimized methodology reached the concentration factor of 250 times and was successfully applied to analyze water samples from hydroponic cultivation of the eucalyptus seedlings. The results showed that the exudation process occurs at glyphosate doses starting from 2?L ha?1.  相似文献   

11.
Abstract

A sudden increase in serum creatinine after paraquat intoxication has been reported in several clinical studies. However, this dramatic change of creatinine may be possibly due to an interconversion of creatine-creatinine in relation to paraquat toxicity. In order to investigate the creatine-creatinine relationship, a liquid chromatography tandem mass spectrometry in combination with electrospray ionization was developed and validated for simultaneous determination of creatine and creatinine in the serum. The chromatographic separation was achieved on a Gemini® C6-Phenyl column with a gradient elution consisting of 0.1% formic acid in ultrapure water and methanol as the mobile phase. The method yielded suitable levels of specificity and selectivity, and calibration curves of creatine and creatinine in serum were linear over the concentration range of 0.5–200?µg mL?1. The limit of quantification of both compounds was 0.5?µg mL?1, and the method was accurate within the recovery range of 96.23–102.75%, indicating the robustness of the method. The method was successfully applied to toxicological samples from paraquat-intoxicated patients, and the concentrations of creatine and creatinine were quantified. High creatine concentrations in serum samples were observed which may lead to high serum creatinine despite normal kidney function as creatine is converted to creatinine in proportion to its concentration.  相似文献   

12.
A rapid and sensitive liquid chromatography tandem mass spectrometry (LC/MS/MS) method for the determination of trace dioctyl sulfosuccinate (DOSS) concentrations in seawater samples has been established. The method is well suited to aquatic environment impact monitoring following application of the dispersant Corexit EC9500A. Linearity of the method was demonstrated down to 0.05 ng/mL?1 (0.05 µgL?1) DOSS in seawater, with a 2.4% relative standard deviation precision for preparation replicates. A US EPA method limit of detection of <0.02 ng/mL?1 (<0.02 µgL?1) was calculated and specificity was confirmed by monitoring of two qualifier ions at 291.1 m/z and 227.1 m/z. These transitions were confirmed by QToF analysis to be associated with the DOSS precursor ion at 421.2 m/z. For application to seawater samples and samples containing oil particulates, a practical and repeatable calibration range of 0.5 ng/mL?1 (0.5 µgL?1) to 25.0 ng/mL?1 (25.0 µgL?1) DOSS is reported. The method was shown to have excellent precision and accuracy, with a consistent ≤1.6% relative standard deviation for system suitability standards at 0.5 ng/mL?1 (0.5 µgL?1) and linear weighted (1/x) regression coefficients of determination ≥0.995. The surfactant nature of the analyte is discussed in relation to detection limit and loss of analyte. Speculation of a relationship between DOSS in association or aggregation with divalent cations, such as Ca2+ present in salt water and hard water, is suggested. The consequent effects on cell ionic balance and membrane function are discussed.  相似文献   

13.
A carbon paste electrode was used for the electrochemical quantification of carbendazim in water and orange juice samples. Carbendazim oxidation on the electrode surface was found to be controlled by adsorption. The novel electrochemical procedure for carbendazim quantification employed differential pulse voltammetry using a carbon paste electrode under optimal conditions. Carbendazim oxidation currents were linear at concentrations of 2.84 to 45.44 µg L?1, with a limit of detection of 0.96 µg L?1. The proposed method was applied to carbendazim quantification in ultrapurified water, river water, and orange juice. Recovery rates in water and orange juice samples were in the 97%–101% range, indicating that the method can be employed to determine carbendazim in these matrices, with advantages including shorter analysis time and lower cost than routine methods such as chromatography or spectroscopy. The electrode showed good reproducibility, remarkable stability, and especially good surface renewability by simple mechanical polishing. The recovery rates observed were highly concordant with those obtained for high-performance liquid chromatography, having a relative standard deviation of less than 1.3%.  相似文献   

14.
Abstract

A simple, very efficient method is presented for routine analysis of herbicide Krovar I? (active components bromacil and diuron) in water and soil samples. Water samples were extracted by liquid–liquid extraction with dichloromethane (DCM) as extraction solvent. For soil samples two different extraction techniques were compared: microwave-assisted solvent extraction and a shaking technique using a platform shaker. Extracts were analyzed by high performance liquid chromatography using a water:methanol gradient. Liquid chromatography was coupled with atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS) for quantification of bromacil and diuron. Optimization of the APCI-MS was done by using standards in the flow injection analysis mode (FIA). Method detection limit for liquid samples for bromacil is 0.04 µg L?1 and for diuron 0.03 µg L?1. Method detection limit for soil samples is 0.01 µg g?1 dry weight for both compounds. Results of analysis of field samples of water and soil are also presented.  相似文献   

15.
Abstract

The aim of the research was to evaluate the effect of consumption of selenium-enriched pork on selected health indicators of probands. The intake of feed mixture with increased organic selenium at the dose of 0.3?mg.kg?1 probably increases selenium concentration in MSM (musculus semimembranosus). In the pork enriched with organic selenium, the concentration was higher by 1.045?±?0.10?mg.kg?1 compared with the control group 0.701?±?0.05?mg.kg?1 at significance P?<?0.001. Sixteen participants in the experiment were represented by 8 men at the average age of 41.5?±?11.9?years and 8 women at the average age of 41.4?±?7.9?years. All the probands consumed meat enriched with selenium three times a week during one month. By consumption of the enriched pork, there was an increase of the selenium concentration in blood serum of probands traced with selenium increase from 73.19?±?15.68?μg.L?1 to 73.73?±?15.13?μg.L?1 (P?>?0.05). From the results we can see that consumption of enriched pork with selenium was significantly manifested in lowering of total cholesterol levels, which was associated with LDL cholesterol lowering (P?<?0.05). Differences among the HDL cholesterol and triglycerides samples were not significant.  相似文献   

16.
Veterinary antibiotics used in agriculture can be introduced into the environment through land application of animal manure, accumulating in soils and groundwaters and posing a significant risk to human health and animal well-being. As the analysis of tetracyclines in soil is challenging due to their strong interaction with soil minerals and organic carbon, the objective of this study was to develop a reliable and reproducible method for quantitative analysis of chlortetracycline and oxytetracycline, and their respective metabolites in soils. A method based on pressurized liquid extraction (PLE) with in-cell clean-up was developed for the extraction of chlortetracycline and oxytetracycline and four likely metabolites from a set of four soils. Optimized conditions included a cell size of 22?mL, soil loading of 5?g, pH of 8.0, methanol:water ratio of 3:1, 50?°C, and two cycles. Soil extracts were analysed by high-performance liquid chromatography (HPLC) coupled with ion trap mass spectrometry (MS). Recoveries of seven tetracyclines from soil ranged from 41% to 110%. The limits of detection for tetracyclines were 0.08–0.3 µg g?1 soil, and intra- and inter-day variation ranged from 0.12–0.34%. The proposed PLE method is suitable for quantification of tetracyclines in agricultural soils at typical concentrations expected in contaminated environments.  相似文献   

17.
The occurrence of five pharmaceuticals, consisting of four anti-inflammatory and one antiepileptic drug, was studied by passive sampling and grab sampling in northern Lake Päijänne and River Vantaa. The passive sampling was performed by using Chemcatcher® sampler with a SDB-RPS Empore disk as a receiving phase. In Lake Päijänne, the sampling was conducted during summer 2013 at four locations near the discharge point of a wastewater treatment plant and in the years 2013 and 2015 at four locations along River Vantaa. The samples were analyzed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in the multiple reaction monitoring mode. The concentrations of carbamazepine, diclofenac, ibuprofen, ketoprofen, and naproxen in Lake Päijänne determined by passive sampling ranged between 1.4–2.9 ng L?1, 15–35 ng L?1, 13–31 ng L?1, 16–27 ng L?1, and 3.3–32 ng L?1, respectively. Similarly, the results in River Vantaa ranged between 1.2–40 ng L?1, 15–65 ng L?1, 13–33 ng L?1, 16–31 ng L?1, and 3.3–6.4 ng L?1. The results suggest that the Chemcatcher passive samplers are suitable for detecting pharmaceuticals in lake and river waters.  相似文献   

18.
MC analysis of biological tissue is considered to be very difficult due to the lack of validated methods. This is the primary limiting factor for monitoring potential risks in both the flesh of aquatic organisms and the aquatic ecosystem. In this study, an effective method to determine free MCs (MC-LR and MC-RR) in the muscle and liver tissues of freshwater cultured fish was developed using solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC/MS-MS). The extraction solvent, time of extraction, eluent and purification of the extract were optimized. Various SPE cartridges were also investigated. In this optimized analytical procedure, an 85% methanol/water solution (v/v) was selected as the extraction solvent, after which the extracts were purified by removing fats and proteins; a HLB cartridge was chosen for MCs enrichment; and 90% methanol containing 0.02% formic acid/water solution (v/v) was used as the eluent. Under the optimized pretreatment conditions and instrument parameters, good recoveries of MC-LR and MC-RR were obtained at three concentrations (0.5, 1.0 and 2.0 µg g?1 dry weight (DW)), with values ranging from 92.5 to 98.3% and 92.1 to 98.6%, respectively. The method detection limit (MDL) for muscle samples was 0.5 µg kg?1 and 0.4 µg kg?1 (DW) for MC-LR and MC-RR, respectively. The MDL for the liver samples was 0.8 µg kg?1 (DW) for both MC-LR and MC-RR. The developed procedure was successfully applied to analyze MCs in the muscle and liver of fish samples collected from a Chinese freshwater aquaculture pond during bloom seasons. The MC-LR concentrations ranged from below the MDL to 4.17 µg kg?1 and the MC-RR concentrations ranged from below the MDL to 2.64 µg kg?1.  相似文献   

19.
The ecotoxic effects of carbaryl (carbamate insecticide) were investigated with a battery of four aquatic bioassays. The nominal effective concentrations immobilizing 50% of Daphnia magna (EC50) after 24 and 48 h were 12.76 and 7.47 µg L?1, respectively. After 21 days of exposure of D. magna, LOECs (lowest observed effect concentrations) for cumulative molts and the number of neonates per surviving adult were observed at carbaryl concentration of 0.4 µg L?1. An increase of embryo deformities (curved or unextended shell spines) was observed at 1.8 and 3.7 µg L?1, revealing that carbaryl could act as an endocrine disruptor in D. magna. Other bioassays of the tested battery were less sensitive: the IC50-72h and IC10-72h of the algae Pseudokirchneriella subcapitata were 5.96 and 2.87 mg L?1, respectively. The LC50-6d of the ostracod Heterocypris incongruens was 4.84 mg L?1. A growth inhibition of H. incongruens was registered after carbaryl exposure and the IC20-6d was 1.29 mg L?1. Our results suggest that the daphnid test sensitivity was better than other used tests. Moreover, carbaryl has harmful and toxic effects on tested species because it acts at low concentrations on diverse life history traits of species and induce embryo deformities in crustaceans.  相似文献   

20.
The implementation of the Water Framework Directive (2000/60/EC) requires the establishment of monitoring programs. However, conventional procedures for sample preparation prior to chromatographic analysis are rather expensive and time consuming, being the development of cost-effective and easy tool a necessity. The aim of this work was to develop an enzyme-linked immunosorbent assay (ELISA) able to determine atrazine in water samples. Matrix effects evaluation showed that the increase of humic acid (HA) concentration leads to flattened calibration curves and to the loss of the sigmoidal shape. However, such interference was overcome, by the presence of an environmental sample buffer, incubated together with the samples. Recoveries from 88.5 to 119.2 % were obtained in the presence of HA concentrations up to 20 mg?L?1. An analytical range from 0.003 to 1 μg?L?1 was obtained, and atrazine was detected in a sewage treatment plant with concentrations ranging from 14 to 52 ng?L?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号