1.
A large number of pressurized coal gasification processes being developed propose to use venturi scrubbers for particulate removal at high pressures. Theoretical predictions based on venturi scrubber performance models indicate that particle collection efficiency will decrease severely in these high gas pressure applications.

An exploratory theoretical and experimental program was performed to study the effect of gas pressure on venturi scrubber performance. Experiments were done on a 0.47 m3/s (1000 acfm) pilot scale venturi scrubber. Particle collection performance was determined as a function of scrubber pressure drop for venturi scrubbers operating In the range of 1-10 atm total pressure. Experimental results confirmed that the particle collection efficiency of venturi scrubbers decreases for a given scrubber pressure drop as total gas pressure Is increased. To achieve the same particle collection efficiency, the pressure drop across a venturi scrubber operated at 10 atm Is about 10 times that of the same scrubber operated at 1 atm pressure.  相似文献   

2.
Abstract

An efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1 μm, the removal efficiency is greater than 80–90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is ~15.4 ± 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m3. A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 μm.  相似文献   

3.
An efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1microm, the removal efficiency is greater than 80-90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is approximately 15.4 +/- 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m3. A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 microm.  相似文献   

4.
Minnesota Power currently has in commercial operation a 500 MW gas cleaning system consisting of a venturi particulate scrubber, integrated with a spray tower SO2 absorber. The system was designed to achieve 99.7% particulate removal and 90% SO2 removal based upon burning a 2.8 % sulfur coal.

Initially the concept of using a venturi for wet particulate collection was selected based upon a significant cost saving of $25 million compared to dry particulate collection devices. Subsequently, the Interaction of particulate collection with SO2 removal provided additional operating cost benefits. Prior to start-up of the commercial system, a pilot plant was used to evaluate various modes of operation. Results showed that alkali contained in the fly ash removed with the venturi was sufficient to meet the alkali requirement for SO2 removal.

Clay Boswell Station Unit No. 4 was started up during March 1980. Since initial start-up the system has exhibited almost 100% availability. EPA compliance testing has confirmed that the system Is meeting its emission standards. The unit is operating with fly ash as the only source of alkali. Since commercial operation started, no external alkali has been purchased.

This paper will discuss the design details of the system and performance of the commercial system.  相似文献   

5.
A study was carried out to investigate the emissions of SO2 and primary sulfate materials (H2SO4 and inorganic particulate matter) from a boiler burning fossil fuel and using a wet-limestone scrubber for SO2 removal. Experiments were designed to assess the scrubbing efficiency for SO2 and sulfate, as well as the potential for scrubber liquor reentrainment. The boiler studied was an 820 MW cyclone-fired unit equipped with a wet, limestone scrubber, consisting of eight two-stage venturi-absorber modules designed to treat a flue gas flow rate of 2,760,000 acfm. The boiler fuel was a low-grade sub-bituminous coal with ash and sulfur contents of 25 and 5%, respectively. Multiple-sampling methods were employed concurrently on the inlet and outlet of a candidate absorber module to measure SO2, total water-soluble sulfate, and free H2SO4. Samples were collected during three field experiments from September 1977 through April 1978. The average SO2 scrubbing efficiency was 76% and was observed to decrease over the 5 day operation/maintenance cycle of the module. The total water-soluble sulfate input to the scrubber amounted to approximately 1% of the total sulfur oxides and was composed of a 5:1 ratio of H2SO4 to particulate sulfate. The total sulfate scrubbing efficiency, averaging about 29%, was invariant with respect to SO2 removal. The sulfate emissions measured in the scrubber exit gas consisted of about 85 % H2SO4 as a fine aerosol. Mass emissions of acid and particulate sulfate were calculated as 1730 Ib/hr and 305 Ib/hr, respectively.  相似文献   

6.
Collection efficiencies are shown for control of fine particles in venturi scrubbers (1) as a function of pressure drop, and (2) as a function of throat area and liquid to gas ratio. A relationship of pressure drop to throat area, gas density, throat velocity, and liquid to gas ratio is given and is used to provide a method for estimating efficiency knowing only these scrubber design parameters. The effect of charged particles and of surface active agents on collection efficiency are discussed briefly.  相似文献   

7.
Theoretical calculations and experimental measurements show that the collection of small aerosol particles (0.05 to 5 micron diameter range) by water droplets in spray scrubbers can be substantially increased by electrostatically charging the droplets and particles to opposite polarity. Measurements with a 140 acfm two chamber spray scrubber (7 seconds gas residence time) showed an increase in the overall particle collection efficiency from 68.8% tit uncharged conditions to 93.6% at charged conditions, with a dioctyl phthalate aerosol (1.05 μm particle mass mean diameter and 2.59 geometric standard deviation). The collection efficiency for 0.3 μm particles increased from 35 to 87% when charged. During 1973–1974 a 1000 acfm pilot plant electrostatic scrubber was constructed inside a 40 ft trailer for evaluation on controlling particu-late emissions from pulp mill operations (funded by Northwest Pulp and Paper Association). Field tests performed on the particle emissions exhausting from SO2 absorption towers treating the gases from a magnesium based sulfite recovery boiler have shown particle collection efficiencies ranging from about 60 to 99% by weight, depending on the electrostatic scrubber operating conditions. Energy requirements for the University of Washington electrostatic scrubber are about 0.5 hp/1000 acfm (350 Watts/1000 acfm) including gas pressure drop, water pressure drop, and electrostatic charging of the water spray droplets and the particles.  相似文献   

8.
A turbulent wet scrubber was designed and developed to scrub particulate matter (PM) at micrometer and submicrometer levels from the effluent gas stream of an industrial coal furnace. Experiments were conducted to estimate the particle removal efficiency of the turbulent scrubber with different gas flow rates and liquid heads above the nozzle. Particles larger than 1 µm were removed very efficiently, at nearly 100%, depending upon the flow rate, the concentration of the dust-laden air stream, and the water level in the reservoir. Particles smaller than 1 µm were also removed to a greater extent at higher gas flow rates and for greater liquid heads. Pressure-drop studies were also carried out to estimate the energy consumed by the scrubber for the entire range of particle sizes distributed in the carrier gas. A maximum pressure drop of 217 mm H2O was observed for a liquid head of 36 cm and a gas flow rate of 7 m3/min. The number of transfer units (NTU) analysis for the efficiencies achieved by the turbulent scrubber over the range of particles also reveals that the contacting power achieved by the scrubber is better except for smaller particles. The turbulent scrubber is more competent for scrubbing particulate matter, in particular PM2.5, than other higher energy or conventional scrubbers, and is comparable to other wet scrubbers of its kind for the amount of energy spent.

Implications: The evaluation of the turbulent scrubber is done to add a novel scrubber in the list of wet scrubbers for industrial applications, yet simple in design, easy to operate, with better compactness, and with high efficiencies at lower energy consumption. Hence the turbulent scrubber can be used to combat particulate from industrial gaseous effluents and also has a scope to absorb gaseous pollutants if the gases are soluble in the medium used for particles capture.  相似文献   

9.
Abstract

In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 µm. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38–99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1–1 µm. In this size range, ESP and baghouse collection efficiencies are 85.79–98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM10 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.  相似文献   

10.
This paper includes results from pilot plant studies and early field demonstration units and a discussion of the application of the limestone wet scrubbing process to a low sulfur syb-butuminous coal. This latter application required the development of a hybrid two stage scrubber to enable collection of the fine particulate matter as well as removal of a significant amount of the sulfur dioxide.  相似文献   

11.
Comparative gas cleaning performance of a pilot-scale venturi scrubber with throat dimensions of 6 in. wide × 1 2 in. long × 1 2 in. deep was obtained for the following three methods of water injection: a system of spray nozzles located along each short side of the throat (Figure 2a); a continuous slot located immediately above the nozzles, along each short side of the throat (Figure 2b); and a weir located 2 ft above the spray nozzles along long side of the throat (Figure 2c). For each method of water injection the gas cleaning performance, as a function of the pressure drop, was measured by two tests: absorption of SO2 and collection efficiency for particles of methylene blue of controlled size.  相似文献   

12.
A simplified equation for specifying the optimum minimum length for commercial venturi scrubber throats is presented in this paper. This theoretical correlation is derived using an optimum velocity ratio (velocity of collector droplet at end of venturi throat to velocity of gas in throat) and is a function of throat gas velocity and liquid to gas ratio. This velocity ratio establishes the minimum throat length and is based on available literature data. Predicted venturi scrubber particle collection for throats specified by this procedure compare favorably with reported commercial venturi collection efficiencies and with modeled venturi efficiencies over the practical range of venturi scrubber operation.  相似文献   

13.
A self-flushing wet electrostatic precipitator was developed to investigate the removal performance for fine particles. Flexible material (polypropylene, 840A) and carbon steel in the form of a spiked band were adopted as the collection plate and discharge electrode, respectively. The particle concentration, morphology, and trace-element content were measured by electric low-pressure impactor, scanning electron microscope, and energy-dispersive x-ray spectroscopy, respectively, before and after the electrostatic precipitator. With increasing gas velocity, the collection efficiency of fine particles (up to 0.8 μm in diameter) increased, while it decreased for particles with diameters larger than 0.8 μm. Increasing the dust inlet concentration increased the collection efficiency up to a point, from which it then declined gradually with further increases in the inlet concentration. The particulate matter after the wet electrostatic precipitator showed different degrees of agglomeration. The collection efficiency of trace elements within PM10 was less than that of the PM10 itself. Notably, the water consumption in the current setup was significantly lower than for other treatment processes of comparable collection efficiencies.

Implications: Wet electrostatic precipitators, as fine filtration equipment, were generally applicable to coal-fired plants to reduce PM2.5 emissions in China. However, high energy consumption and unstable operation, such as water usage and spray washing directly in the electric field, seriously restricted the further development. The utilization of self-flushing wet electrostatic precipitator can solve these problems to some extent.  相似文献   


14.
A novel aspirative wet scrubber system makes use of condensation forces to enhance fine particulate collection. A pressure gain of 2 to 4 inches, W.C. is generated by the system and total water pump power requirements for multistage systems are 2 horsepower per thousand scfm. of gas throughput. No fans or blowers are utilized. When scrubbing hot combustion products carrying 0.1 to 6.0 micron metal oxide particles from a kiln, total collection efficiency was 99.4%. Collection of fly ash, in the particle size range 0.1 to 10 microns, has been measured at 99.5% efficiency.  相似文献   

15.
The problems associated with the design and operation of appropriate air pollution control equipment for particulate emissions from dryer-drum hot asphalt plants are discussed by outlining the basic process involved, the quantities of particulate matter being emitted, and possible methods of control. The most difficult problem seems to be the emission of a fine aerosol of unburned hydrocarbons generated as a result of the simultaneous heating and mixing of the asphaltic material. From the information presented, it was concluded that in most circumstances the venturi scrubber would be the most viable alternative to meet the 0.04 gr/dscf limitation imposed by the New Source Performance Standards promulgated by the EPA.  相似文献   

16.
Abstract

Two types of media, a natural medium (wood chips) and a commercially engineered medium, were evaluated for sulfur inhibition and capacity for removal of hydrogen sulfide (H2S). Sulfate was added artificially (40, 65, and 100 mg of S/g of medium) to test its effect on removal efficiency and the media. A humidified gas stream of 50 ppm by volume H2S was passed through the media-packed columns, and effluent readings for H2S at the outlet were measured continuously. The overall H2S baseline removal efficiencies of the column packed with natural medium remained >95% over a 2-day period even with the accumulated sulfur species. Added sulfate at a concentration high enough to saturate the biofilter moisture phase did not appear to affect the H2S removal process efficiency. The results of additional experiments with a commercial granular medium also demonstrated that the accumulation of amounts of sulfate sufficient enough to saturate the moisture phase of the medium did not have a significant effect on H2S removal.

When the pH of the biofilter medium was lowered to 4, H2S removal efficiency did drop to 36%. This work suggests that sulfate mass transfer through the moisture phase to the biofilm phase does not appear to inhibit H2S removal rates in biofilters. Thus, performance degradation for odor-removing biofilters or H2S breakthrough in field applications is probably caused by other consequences of high H2S loading, such as sulfur precipitation.  相似文献   

17.
An intensive field study was conducted in Research Triangle Park, North Carolina in the fall of 1986. Ambient concentrations of the following constituents were obtained: nitric acid, nitrous acid, nitrogen dioxide, sulfur dioxide, ammonia, hydrogen ion, and particulate nitrate, sulfate, and ammonium. Results collected using the annular denuder system (ADS) and the transition flow reactor (TFR) are presented and compared.

Both types of samplers had operational detection limits on daily (22-hour) samples that were generally below 1 μg m-3 suggesting that both samplers can provide sensitive measurements for most of the constituents of interest. Both the ADS and TFR show reasonable (>25 percent) within-sampler precision for most of the measured species concentrations, except TFR fine particulate nitrate measurements where results were frequently negative (The TFR fine particulate nitrate measurement is calculated using subtraction of positive numbers).

Comparison of ADS and TFR daily results showed good agreement for total particulate sulfate, the sum of total (coarse plus fine) particulate and gaseous nitrate, and ammonia. As a result of different inlet particle collection efficiencies, the ADS fine particulate sulfate exceeded the TFR (5 percent). In the absence of a filter to collect volatilized particulate ammonium in the ADS, the sum of total particulate and gaseous ammonium in the TFR exceeded that in the ADS. Of potentially more importance, ADS measurements of SO2 and H+ exceeded those of the TFR, while TFR measurements of HNO3 exceeded those of the ADS. Results of this study suggest that the TFR may provide biased measurements of SO2, H+, HNO3, and Fine NO3 - that cannot be corrected without modifications to the fundamental design of the sampling system.  相似文献   

18.
A concise, quantitative picture of the state of the art of particle scrubbing is presented in the form of performance prediction methods. A new relationship between the particle diameter collected at 50% efficiency and scrubber pressure drop for several of the most common scrubber types is a design tool of great utility. Scrubber capability for the collection of submicron particles by diffusion is described in a graph for several scrubber types.  相似文献   

19.
Abstract

Emissions of sulfur trioxide (SO3) are a key component of plume opacity and acid deposition. Consequently, these emissions need to be low enough to not cause opacity violations and acid deposition. Generally, a small fraction of sulfur (S) in coal is converted to SO3 in coal-fired combustion devices such as electric utility boilers. The emissions of SO3 from such a boiler depend on coal S content, combustion conditions, flue gas characteristics, and air pollution devices being used. It is well known that the catalyst used in the selective catalytic reduction (SCR) technology for nitrogen oxides control oxidizes a small fraction of sulfur dioxide in the flue gas to SO3. The extent of this oxidation depends on the catalyst formulation and SCR operating conditions. Gas-phase SO3 and sulfuric acid, on being quenched in plant equipment (e.g., air preheater and wet scrubber), result in fine acidic mist, which can cause increased plume opacity and undesirable emissions. Recently, such effects have been observed at plants firing high-S coal and equipped with SCR systems and wet scrubbers. This paper investigates the factors that affect acidic mist production in coal-fired electric utility boilers and discusses approaches for mitigating emission of this mist.  相似文献   

20.
Abstract

A three-dimensional mathematical model was used to predict the removal efficiency of a venturi scrubber for SO2 absorption into a water and alkaline solution. In order to obtain better results, nonuniform droplet concentration distribution was considered. The results of the model with nonuniform droplet concentration distribution are compared with several sets of experimental data, as well as with prediction data of a mathematical model with uniform droplet concentration distribution. Without exception, all comparisons indicated that including nonuniformity of droplet concentration distribution in the model will significantly improve the agreement between the experimental data and predicted values.  相似文献   